1. EYE 02 camera Switch the camera into Enroll mode it is described in chapter 1 2 Insert battery into the thermostat TP 82 or TP 83 Enrolling thermostats and camera into wireless socket AC 88 First reset the socket You can skip this step if no other device is enrolled there The steps are described in the chapter 5 2 1 step 1 Plug the socket into the mains LED indicator flashes once Right afterwards press and hold the button on the socket until the LED indicator flashes once in intervals Insert battery into the thermostat TP 82 or TP 83 Press the socket button to finish the enrollment mode Unplug the socket from the mains Plug the socket into the mains LED indicator flashes once Right afterwards press and hold the button on the socket until the LED indicator flashes once in intervals Send enrollment signal from the camera Go to JabloTool via internet tab Peripherals press Add new device Other options are described in the chapter 4 1 1 step 3 The wireless socket will now make contact if thermostat gives command to increase the temperature File name URL EYE 02 Wireless peripherals 12 12 o http www jablocom com download E Co M
2. Enrolled wireless devices can be further configured in Jablotool via internet or via USB cable Wireless devices are described in more detail in user manual of each peripheral on www jablotron cz l Devices Events Reporting Video George Technical Support camera List of external devices Device Name RC 80 Remote control JA 80L Indoor siren JA 804 Outdoor siren RC 85 Tansmitter car Add new device Picture 2 Screenshot from JabloTool via internet tab Peripherals Filename EYE 02 Wireless peripherals 3 12 URL http www jablocom com download Cc CO VM External document Wireless buttons inform the camera and its user when a person presses them 4 button wireless remote control RC 80 Remote control can switch camera into WATCH SLEEP CONFIG and ENROL mode User can also test camera internal detectors This remote control is delivered with the camera Additional controls allow more people to operate the camera independently by Personal HELP button by Wall buton to emergency numbers to selected person Help button RC 87 Pushing the button causes Panic alarm even if EYE 02 is in SLEEP mode Example of use Elderly people who may be in emergency due to sudden drop in their health condition simply press the panic button and the camera will report the Panic alarm via SMS MMS call email or JabloTool server and contact parents neighbours or hospital for help Wireless wall butto
3. detector JA 85B JA 85B detects breaking of a window at the distance of up to 9 meters It uses digital signal processing to avoid false alarms 3 1 Enrolling detectors e Switch the camera into Enroll mode Go to JabloTool via internet tab Peripherals and click on Add new device Other possibilities of switching camera to Enroll mode are described in chapter 1 2 e Press any button on these detectors RC 80 RC 85 RC 87 RC 88 RC 89 e Insert battery into these detectors JA 80D JA 80IR JA 80M JA 80P JA 80PB JA 80S JA 80W JA 81M JA 82M JA 82SH JA 85B JA 85P JA 86P JA 88P e Plug the detector JA 80G into the mains Detectors should be at least 1 meter away from the camera during enrolment The primary function of sirens is to inform visually and acoustically about Alarm events Wireless internal siren JA 80L JA 80L is a mains powered 230V AC siren with multiple functions lt sounds when Alarm in the camera occurs The sounding can be activated and its length adjusted between 0 seconds and 4 minutes go to JabloTool Peripherals then click on the enrolled JA 80L The same length of alarm indication applies to the siren JA 80A if it is enrolled in same the camera The siren confirms intruder alarm to the camera when it is disconnected from power during the time while it sounds an Alarm Siren can signalize entrance or exit delay with a beep Entrance and exit delay can be adjusted in JabloTool tab Settings Detect
4. sirens communicate with the EYE 02 camera i e they report information about device status The camera obtains information e when camera does not receive regular reports from the peripheral communication with peripheral is interrupted or camera starts receiving regular reports from the peripheral again communication with peripheral is recovered when detector battery is low or there is failure in AC power when detector is powered from the mains when tampering unauthorized manipulation into detectors or sirens happened Information is sent by the peripheral even when the camera is in SLEEP mode If you need to replace the battery in the peripheral switch the camera to CONFIG mode to avoid false alarms Filename EYE 02 Wireless peripherals 2 12 2 URL http www jablocom com download k Co M External document 1 2 Enrolling peripherals When you enroll new peripherals you will need to switch the camera into Enroll mode This is possible by 1 Using wireless remote control RC 80 o Press simultaneously both buttons in the right column o Press button with the symbol 2 Using JabloTool via internet o Connect to your camera via www jablotool com o Goto tab Peripherals o Click on Add new device 3 Using JabloTool via USB cable o Click on the icon of camera in the list of on line devices o Goto Configuration External devices and click on Add new device Exact enrolment procedure is described separately for each category of peripherals
5. 0S detects the presence of fire inside a building It reacts to visible smoke or when a critical temperature in the room is exceeded It contains a built in local warning siren The detector complies with EU Directives 98 34 ES and 98 48 ES stating the obligation to mount fire detectors in new buildings Please contact the manufacturer Jablotron for more information Wireless gas leak detector JA 80G JA 80G is activated by combustive gases or fume leakages This detector is mains powered 230V AC because of higher power consumption Besides wireless signalling to EYE 02 it also provides a relay switch to shut down an electric gas inlet valve if installed Filename EYE 02 Wireless peripherals 6 12 o URL http www jablocom com download k Co M External document Wireless optical barrier JA 80IR JA 80IR optical barrier indicates breach into a protected area by crossing the infra red line between the transmitter and the receiver It is a product of company Optex supplemented with transmitters compatible with OASIS system The transmitter and receiver are enrolled into the EYE 02 as one device each together as two devices There can be up to 60m distance between the units JA 80IR can well be used in outdoor environment it is protected from dust and flushing water Mini size wireless PIR motion detector JA 85P JA 85P is a mini size PIR sensor suitable for protecting small rooms it can be fit on ceiling Mini size wireless glass break
6. 10 seconds after plugging in and hold it e until the LED indicator flashes once in intervals the socket enters the Switch ON normal mode The socket will make contact if camera switch is turned ON or e until the LED indicator flashes twice in intervals the socket enters the Switch OFF inverse mode The socket will disconnect contact if camera switch is turned ON It will make contact if camera switch is turned OFF 4 Send the enrolment signal from the camera e Goto JabloTool via internet tab Peripherals and click on Add new device Other options are described in the chapter 4 1 1 step 3 Now the smart socket will respond to switching ON or OFF the first camera switch DeviceX 5 2 2 Enrolling AC 82 and UC 82 1 First reset the relay You can skip this step if no other device is enrolled there e Undo the cover and repeatedly press the button of the first relay X achieve the highest number of LED flashes 4 or if not possible then 3 e Press the same button and keep it pressed until all the LEDs flash a couple of times reset Filename EYE 02 Wireless peripherals 10 12 d URL http www jablocom com download fi Co M External document e Repeat the reset procedure with button of the second relay Y 2 Enroll the camera into relay X or Y Repeatedly press the relevant X or Y button until 4 LED lights flash 3 Send the enrolment signal from the camera e Goto JabloTool via internet tab Peripherals and click on Add new devic
7. External documen t o e COM Wireless peripherals EYE 02 GSM Security Camera Application note File name EYE 02 Wireless peripherals 1 12 D COM External document The application note describes possibilities of using camera EYE 02 with wireless peripherals from the OASIS system manufactured by Jablotron Alarms OASIS system is based on the principle of control panel communicating with wireless peripherals When the peripherals are used with camera EYE 02 the camera plays the role of the control panel Camera EYE 02 is equipped with 7 internal detectors and 2 programmable switches Wireless peripherals further expand camera capabilities 1 1 Overview of peripherals Five types of peripherals can be used with the camera wireless buttons detectors sirens relays and thermostats personal HELP button Sa gt AZ motion detector internal siren wall button doorbell button door window opening detector smoke detector outdoor siren thermostat smart socket x Picture 1 Examples of peripherals used with EYE 02 Up to 20 wireless peripherals can be used with the camera at the same time Operating range of peripherals is 100m in free space Wireless buttons detectors and sirens are powered by batteries with typical lifetime of at least 2 years Exact battery lifetime depends on the battery type used and it is mentioned in the manual of each peripheral Detectors and
8. ains socket e Press and hold the siren button and plug the siren in the mains socket e Keep the button pressed until two beeps are heard which confirms a reset 2 The indicator keeps flashing after reset device is in enrolment mode 3 Send the enrollment signal from the camera e Goto JabloTool via internet tab Peripherals and click on Add new device or e Go to JabloTool via USB click on the icon of camera in the list of on line devices go to Configuration External devices and click on Add new device or Note Do not use remote control to switch the camera in the Enrol mode when siren is in Enroll mode because the remote control would then enroll into the siren 4 1 2 Enrolling JA 80A 1 Reset the siren by unplugging its battery Do the reset if another device has been previously enrolled in the siren 2 Switch the camera into enroll mode The options are described in the chapter 1 2 3 Insert battery into the siren The siren stops flashing after it is enrolled Relay modules make or disconnect electrical contact to the commands by the camera Relays may have the shape of AC power socket that can be directly plugged into the AC 230V mains or boxes to which wires of electric circuit are attached The relays are powered by the mains AC 230V relays AC 82 and AC 83 or by 12V DC relays UC 82 5 1 Using smart socket and relay modules Camera EYE 02 is equipped with two virtual switches These switches work as wirelessly sent
9. ample 3 You leave home for a longer time Before you return you would like to have your home heated to comfortable temperature You will use the relay AC 83 together with thermostat TP 83 You will remotely turn ON the relay The thermostat will start controlling the relay which will turn on the heating Your rooms will be heated to predefined temperature before you arrive If you wish to maintain only minimum economical temperature you switch the relay OFF Camera switches can be configured to several modes SMS ON OFF Switch will turn ON or OFF after pressing a button in JabloTool or after sending an SMS command Example of use Turning ON or OFF heating at home SMS ON OFF pulse Switch turns ON for a specified period of time after which it turns OFF again The period of time can be specified in SMS command If no time is specified the Switch will turn OFF automatically after 2 seconds Example of use Switching garden sprinkler ON for 2 hours WATCH camera switched into Switch will turn ON and will remain turned ON as long as camera is in WATCH mode WATCH mode Panic alarm external detector Switch will turn ON for 120 seconds generated Panic alarm Fire alarm external detector Switch will turn ON for 120 seconds generated Fire alarm Switch will turn ON for the predefined wake up time The time can be configured in JabloTool via USB gt Configuration General settings AC fault AC power failed Switch will turn ON and remain
10. and pets Alarm is generated when motion is detected by both PIR sensors Wireless outdoor PIR detector JA 88P The detector is used outdoor It is product of company Optex supplemented by transmitters from the OASIS system Mask foils supplied with the detector can be applied to adjust the detection area Detector is protected from dust and flushing water IP55 Wireless magnetic door detector JA 80M Wireless magnetic door detector amp universal transmitter JA 81M Universal transmitter JA 80D JA 80M and JA 81M contain a magnetic sensor which is activated when the other magnetic part of detector is moved away e g when a door or a window is opened Example of use A user wants to have a list of people who entered a building Opening the door causes an alarm event and the camera records video for selected time after the door was opened JA 80M JA 81M and JA 80D also have terminal point to which an additional detector can be connected by wires Universal transmitter JA 80D wirelessly indicates status of connected peripheral typically a detector Any comercially available external sensor can be used JA 80D does not have its own magnetic sensor Filename EYE 02 Wireless peripherals 5 12 o URL http www jablocom com download k Co M External document oK ei on JA 81M is also equipped with wireless transmitter of device status Example of use JA 80M or JA 81M is placed on the door to a room On the floor
11. commands to relays to make or disconnect their contact The switches can be remotely controlled in JabloTool via internet or via USB cable They can also be controlled by SMS commands When the peripherals are turned ON by the camera they make contact and appliances powered via these peripherals are turned ON When they are turned OFF they disconnect contact and appliances are turned OFF Relays can also be set to inverse mode they disconnect the contact when they are turned ON and vice versa Filename EYE 02 Wireless peripherals 8 12 o URL http www jablocom com download k Co M External document Watering system Picture 5 Using EYE 02 camera with relays Example 1 On your cottage you have a watering system with water pump placed in the well You connect the power supply of the pump via the relay AC 82 Then you remotely turn on the watering in your cottage You can adjust the time for which you turn on the watering depending on the weather You can also turn the watering on for unlimited period of time until you remotely turn the watering off Example 2 You automatically turn off domestic appliances by switching the camera into WATCH mode when you leave home You connect the appliances into the mains via the smart socket AC 88 After you return you switch the camera into SLEEP mode and the appliances will turn on again This minimizes the risk of fire when you are not at home and it reduces consumption of electricity Ex
12. e Other options are described in the chapter 4 1 1 step 3 Relay will now respond to wireless instructions of camera switches If you enrolled the camera into the first relay switch X the relay will be controlled by camera switch DeviceX If you enrolled the camera into second relay switch Y the relay will respond to instructions of the camera switch DeviceY 5 2 3 Enrolling AC 83 1 First reset the relay You can skip this step if no other device is enrolled there e Undo the cover and repeatedly press the button of the first relay switch X to achieve several LED flashes e Continuously press the same button and keep pressing it for approx 4 seconds until all the LEDs flash a couple of times reset Then release the button e Repeat the reset procedure with button of the second relay switch Y 2 Enroll the camera into the relay X or Y Use the X or Y button depending on to which relay you want to enroll the camera Enter enrollment mode of relay this is indicated by red LED No 2 or 4 flashing by pressing its button X or Y 3 Send the enrollment signal from the camera e Goto JabloTool via internet tab Peripherals and click on Add new device Other options are described in the chapter 4 1 1 step 3 Thermostats control temperature in heated premises They control a relay and automatically switch it ON or OFF If temperature in the room is lower than set temperature the thermostat sends switches the relay ON The relay
13. makes contact and the heating turns ON Camera can be enrolled into relay where thermostat is enrolled Camera then works as a central switch If camera switched the relay OFF the relay will only make contact when the temperature decreases below the economical temperature If camera switches the relay ON the relay will always follow the command from thermostat To work like this the relay needs to be enrolled in the camera and thermostat needs to be enrolled in the relay Thermostat can be also enrolled directly to the camera Thermostat will then report to the camera when battery in the thermostat is flat e when temperature decreases below preset level event Panic Alarm is generated in the camera this can indicate that heating system has stopped working or there may be danger that heating system will freeze e when temperature exceeds 60 C event Fire Alarm is generated in the camera More thermostats can be enrolled into one wireless relay Heating is then turned ON if at least one thermostat requires this Wireless thermostat TP 82 Programmable wireless indoor thermostat TP 83 TP 82 and TP 83 measure and set temperature that should be maintained in a room Temperature adjustment is performed by turning the setting knob Thermostats are enrolled into relay modules AC 82 UC 82 AC 83 or wireless socket AC 88 These relays then control the heating according to thermostat commands The relays can be then also enrolled into the camera so the
14. n RC 88 Wireless doorbell button RC 89 Pressing the button generates Panic alarm even when EYE 02 is in SLEEP mode Example of use The camera Is focusing on entrance area in a building Pressing the doorbell button wakes the camera up The camera registers this person without generating ALARM and begins to record video of entrance area The doorbell button RC 89 can be used in combination with indoor siren JA 80L which sounds a melody after the doorbell button is pressed Wireless transmitter RC 85 It switches the EYE 02 into SLEEP and WATCH mode or generates Panic alarm Example of use You have a water pump in remote location and you wish to be informed when the pump is turned on You set the RC 85 to generate Panic alarm when the electric circuit is closed The camera will then record video of the reservoir with the water pump and it will also inform you by SMS MMS e mail or by sending information to JabloTool server 2 1 Enrolling wireless buttons e Switch the camera into Enroll mode Go to JabloTool via internet tab Peripherals and click on Add new device Other possibilities of switching camera to Enroll mode are described in chapter 1 2 Filename EYE 02 Wireless peripherals 4 12 o URL http www jablocom com download f Co M External document e Press any button on wireless buttons RC 80 RC 85 RC 87 or e Insert battery into RC 88 RC 89 Detectors expand the area which camera monitors and also enable the came
15. nects contact when it is turned ON Wireless relay output module UC 82 Wireless relay output module AC 82 Wireless relay output module for heating control AC 83 UC 82 and AC 82 have two remotely controllable relay outputs for a wide range of appliances like turning ON OFF lighting heating watering etc Relay module AC 83 provides three remotely controllable relays The module automatically makes contact on all its three relays once in 7 days This function reduces the amount of sediments in heating system and it cannot be disabled AC 83 is suitable only for control of heating systems 5 2 Enrolling smart socket and relay modules A relay needs to know which camera it should listen to That is why the camera needs to be enrolled into the relay 5 2 1 Enrolling AC 88 1 First reset the socket You can skip this step if no other device is enrolled there e Unplug the socket from the mains and plug it in again The LED indicator will flash for a short moment e Then press the button on the socket within 10 seconds after plugging in the LED indicator will flash once and hold it until the LED indicator starts flashing four times per second e Release the button to enter the reset mode e To perform the reset press the button and hold it again until the LED indicator goes off approx 3 seconds e Unplug the socket from the mains 2 Plug the socket into the mains LED indicator will flash for a short moment 3 Press the socket button within
16. of the room there is also a step on sensor any commercially available that closes electrical circuit when a person steps on it normally open sensor Peripherals then report to the camera that external sensor has been activated External sensor which disconnects the electrical circuit after its activation normally closed sensor can be also used JA 81M can be used with Shutter movement detector CT 01 which detects unauthorized movement of external shutters on buildings It can be also used with flood detector LD 81 that signals flooding of rooms or cellars Wireless magnetic window and door detector JA 82M JA 82M is an invisible magnetic sensor which can be easily installed on the majority of window and door frames Its magnetic sensor is activated when the other magnetic part of detector is moved away Detector then causes Alarm when camera is in WATCH mode Detector can be enrolled into wireless internal siren JA 80L that will signalize with melody when windows or doors are open Wireless shock and tilt detector JA 82SH JA 82SH is able to detect vibration and tilt of doors and windows Example of use You need to guard a factory hall with high level of noise e g machines running Glass break detector would not notice the specific sound of breaking glass in the noisy environment So shock and tilt detector will inform you when someone breaks or opens the window at night Wireless fire Smoke and temperature detector JA 80S JA 8
17. ors from the group RC 8x and JA 8x can be enrolled into the siren The siren plays a melody after the detector is triggered Different melodies can be associated with different detectors Example of use Siren plays a melody after a Doorbell button RC 89 at the entrance is pressed The siren plays a different melody when that back door at home is open Door detector JA 80M The siren sounds Alarm when there is a fire in the kitchen Fire and smoke detector JA 80S More detectors can be enrolled at the same time Filename EYE 02 Wireless peripherals 7 12 o URL http www jablocom com download f Co M External document Wireless outdoor siren JA 80A JA 80A is completely wire free siren in a solid housing It signalizes intruder alarm acoustically and by red LED lights The length of sounding in case of an alarm event can be set between 0 seconds and 4 minutes go to JabloTool Peripherals then click on the enrolled JA 80A If the internal siren JA 80L is also enrolled it sounds alarm for the same period of time The siren is battery powered Maximum battery lifetime is 3 years Opening the cover signalizes Alarm unauthorized manipulation to the camera LED lights keep flashing for 30 minutes after Alarm 4 1 Enrolling sirens Siren should be at least 2 meters away from the camera during enrolment 4 1 1 Enrolling JA 80L 1 Reset the siren if it has been previously enrolled in another device e Unplug the siren from the m
18. ra to report additional events e g Fire alarm generated by Fire and smoke detector Wireless PIR motion detector JA 80P Connecting of additional PIR sensors allows extending of the monitored area for spaces that do not need to be monitored visually External PIR sensors also extend the distance at which the camera can detect motion by passive infrared detection Example of use Using detectors JA 80P to monitor motion in big factory hall Wireless PIR motion glass break detector JA 80PB s The detector combines PIR motion detector and dual glass break detector This combination makes it suitable for areas accessible through windows JA 80PB enrols into the camera as two independent detectors The enrolment procedure is described in the detector manual It is analogical with enrolment procedure of detector into the Jablotron OASIS control panel Wireless PIR MW microwave detector JA 80W JA 80W is PIR motion detector combined with microwave MW motion detector It is designed to detect human body movement inside buildings When PIR detector registers movement the MW detector is activated and confirms activation of the PIR detector After the confirmation the detector reports Alarm to the camera The detector is enrolled as one peripheral into the camera Wireless dual zone PIR motion detector JA 86P The detector is used indoor where you need to detect movement of persons and avoid false alarms triggered by moving domestic animals
19. turned ON until AC power is recovered Example of use Relay UC 82 will turn ON diesel power generator after AC power failure Light ON camera infrared Switch will turn ON and remain turned ON as long as camera infrared illumination was turned ON illumination is turned ON Example of use Smart socket AC 88 will turn ON external infrared illumination after camera activates its internal infrared illumination This will increase the reach at which pictures can be taken at night File name EYE 02 Wireless peripherals 9 12 o URL http www jablocom com download fi Co M External document Camera switches can be controlled and configured in JabloTool via internet www jablotool com tab Peripherals or in JabloTool via USB cable tab Configuration External devices Switches can also be controlled by SMS commands if they are switched to SMS ON OFF or SMS ON OFF pulse mode Switches are called Devices in SMS commands Example of SMS command lt Remote Access Password gt DeviceX ON will switch the DeviceX ON Example of SMS command lt Remote Access Password gt DeviceX ON 02 00 00 will switch the DeviceX ON for 2 hours For more information on SMS commands see the camera manual Wireless socket AC 88 It is relay made as do it yourself solution You can remotely turn ON and OFF all domestic appliances lighting heating watering etc powered by the mains AC 230V It can be also used in the inverse mode it discon
20. y can be remotely turned ON and OFF by the camera TP 83 has a programmable weekly heating schedule It is capable of recognizing warm up persistence characteristics within 2 days and it will adjust the settings accordingly You only set at what time you wish to achieve the selected temperature and the thermostat will within 2 days prior to this moment adjust the heating so that the set temperature is achieved File name EYE 02 Wireless peripherals 11 12 o URL http www jablocom com download k Co M External document 6 1 Enrolling thermostats into relays and enrolling relays into the camera Relay can be controlled by both thermostat and the camera as described above Follow these steps 1 2 Enroll the thermostat into the controlling relay e Reset the relay AC 82 UC 82 it is described in chapter 5 2 2 step 1 or AC 83 it is described in the chapter 5 2 3 step 1 e Switch the relay into enroll mode o AC 82 or UC 82 Repeatedly press the relevant X or Y button of the relay until all 4 LED lights flash o AC 83 press the button X or Y enroll mode is indicated by red LED number 2 or 4 flashing e Insert battery into the thermostat TP 82 or TP 83 Enroll the camera into the controlled relay it is described in the chapter 5 2 2 5 2 3 steps 2 and 3 Please note that thermostat cannot be enrolled into a relay where camera is already enrolled 6 1 1 1 2 A gt N a Ore Enrolling thermostats into