1. healthcare pISys assembly manual for GO WorkCenter PISIS healthcare section one workcenter assembly eisys healthcare 2 rev 11 4 2010 TABLE OF CONTENTS section one workcenter assembly Tools Hardware 0cc0008 4 COMmponentts cceceeeeeeees 5 Frame Layout cccccceeee 5 Feet ASSEMDI ccceee eee 6 Resetting Control Panel T Gas Spring Preperation 8 Attaching the Table Top 9 section two accessory installation Tools Hardware c00008 11 Preparing the Table Top 12 Attaching Accessories Mounting Rail Posts 16 Mounting Rail cc ee 16 Mounting Rail Accessories 17 Mounting Table Top 17 Accessories Mounting Table 06 19 Frame Accessories Mounting CPU 06 20 UPS Holders Rail Mounted Light 22 Assembly Contact Information 25 and Assistance TOOLS NEEDED FOR WORKCENTER ASSEMBLY Phillips amp flat head screwdriver 1 Phillips Bit Metric Allen wrenches 2 8mm Long T handle 4mm helpful Wrench or socket 7 8mm Torx head screwdriver T25 HARDWARE LIST FOR WORKCENTER ASSEMBLY FRAME Column Mounting Plate screw T25 20mm 4 at each end of each column already installed Table Top mounting Allen bolt 5mm or 4mm x 25mm 8 supplied 1 COMPONENTS Box
2. A Frame and optional accessories Box B Table top Support Structure Cable Outlets 3 Unpack and layout all components from box A All the fasteners are in individual bags taped to the relative component e A Frame B 2 short feet 2 long feet Options e C Monitor rail D 2 monitor rail posts e E Cable Tray with or without MBMOU and power strip e F Accessory Boxes 2 FRAME LAYOUT e Lay frame upside down The control panel cable always exits the cross rail at the back of the frame e Motor housing is flush with the back side of frame The angled side is the front of the frame The short legs always attach at back of frame The long legs always attach at front of frame eisys healthcare 5 rev 11 4 2010 ee ee 3 FEET ASSEMBLY e Using 4mm long T handle Allen wrench loosen but do not remove completely Allen bolts on foot binding clamp pic 1 e Align foot and binding clamp in grooves of leg pic 2 and slide down to the numbered markings pic 2a e pic 2a The top of the foot when frame is turned upright should stop on the line between zero 0 and one 1 This sets the minimum table height to 68cm 26 75 and will al low for adequate bottom of frame clearance for most floor ing surfaces including carpet NOTE f customer requests a change in height you may line up the feet on higher numbers if you want the minimum table height to be greater tha
3. E T E Se ealthcare l9 h section two accessory installation eisys healthcare 10 rev 11 4 2010 TOOLS NEEDED FOR ACCESSORY INSTALLATION e Phillips head screwdriver e 1 Phillips Bit e Metric Allen wrenches 2 8mm Long T handle 4mm helpful e Wrench or socket 7 8mm Hardware List section two Rail Post mounting Allen bolt 6mm x 50mm 4 supplied Rail Post mounting Allen set screw 4 supplied installed Phillips 3 4 wood screw used for Light Ballast 4 unless Generation I Cable Tray is used Cup Holder 3 Phillips 1 1 2 wood screw Light Control switch box 2 Wire management clips for Control Panel Cable eisys healthcare 11 rev 11 4 2010 O E eee 1 PREPARING TABLE TOP 6A Multi Outlet Strip Cable Tray Generation Il 6B Control Panel 6C Pencil Tray 6D Cup Holder 6E User s Manual 6F Wire Management pic 1 Pic 1 shows position of all standard optional accessories attached to the bottom of the table top and of user s manual placement location e Open Box B table top with finished top facing down exactly as shown in pic 1 this makes for easier installation of accessories and frame Space permitting Note Pre tapped holes are used to aid in accessory placement on underside of top 1A Multi Outlet Strips amp MBMO U MBMOU is an adapter plate used to mount power strips to Generation Cable Tray The 2 Duplex and 4 Duplex can also be mo
4. Z6 SPE accessory pic 1 pic 2 pic 3 pic 4 e Remove SPE accessory from box including bag with 2 spacers as shown pic 1 NOTE When mounting GMZC6 IN BOARD in conjunction withe the NEW eisys HINGED CABLE TRAY the SPE accessory MUST be installed to protect the CPU from cable tray collision when loweing the desk e Install SPE as shown once you have set the proper width of the SP for your particular CPU tower pic 2 NOTE The SPE slides under the SP rear rod and over the front rod e Next select the appropriate spacer to allow secure tightening of the SPE to the SP rear extension rod pic 3 e Align and finger tighten knurled screw with spacer After final placement of CPU in holder finish tightening both knurled screws to their final secure position pic 4 e Finished product should be as shown pic 5 NOTE opposite side installation is identical pic 5 eisys healthcare 21 rev 11 4 2010 8 ASSEMBLY OF RAIL MOUNTED LIGHT WLTC Shown from front with shield rotated to Shown from back with shield removed aim light on wall Shield may be rotated as desired to aim light in any direction TOOLS NEEDED FOR ASSEMBLY Phillips head screwdriver Allen wrench 5 mm 8 1 COMPONETS A Ballast Housing w ballast 4 3 4 Phillips Head wood screws B Light shield B 1 Optional Blue Lens C Flourescent lamp amp cable D 1 Desk mounted switch box 2 1 Phillips Head wood screws E Li
5. accessory arms should be spaced equally across rail pic 1 A Advanced Height B Manual C Phone Post D WLTC Indirect Light Adjustable Arm LCD holder TSA RF See Section 7 model 3500 model LCD QRE RF 250 450 800 RF 4A Mounting Advanced Height Adjustable Arm pic 1B pic 2 pic 4 e Place accessory on rail in approximate final location Secure V clamp with 2 4 Allen head bolts pic 1A in front 1B in back e Attach 100mm VESA plate to monitor using same 4 screws supplied with monitor or the 4 longer BLACK screws supplied with each Advance Height Adjustable Arm pic 2 4B Mounting Third Rail Support Post e Place accessory on rail in approximate final location Mark screw locations pic 1 Drill holes in desktop for each screw pic 2 e Attach post with supplied 4 Allen Bolts pic 3 and half washer on bottom pic 4 Pia pic 3 pic 4 eisys healthcare 17 rev 11 4 2010 4B MOUNTING MANUAL HEIGHT ADJUSTABLE ARM e Place accessory on rail in approximate final location Once in final location completely secure by securing V clamp with 2 4 Allen head bolts e Attach 100mm VESA plate to monitor using screws supplied with monitor pic 2 e LCD Holder quick release plate Slide monitor with plate into quick release receiver on the end of the monitor arm When firmly seated the release arm on the VESA will lock into place into the receiver Pic 3 Shown without moni
6. f 11 pic 2 To add the extensions remove from below storage area and remove the factory installed outside support plate and turn to the underside Remove the 2 Allen head set screws with the supplied Allen wrench Insert the smaller end of the extensions hole for the set screw facing down into the standard tubes Replace the set screws insert the end caps from the accessory pack and replace the support bracket Adjust to width of CPU and tighten thumb screws pic 3 2 Mounting the GMCZ 6 on the workcenter leg pic 4 This can be mounted to the outside of either leg on the work center preferably out of foot area If mounted inside then the maximum height of the CPU case cannot exceed 20 3 4 due to the crossbar of the desk frame Once this is determined use the supplied 4 Allen wrench to tighten the clamp to the leg profile of the leg at the highest point on the leg 3 An additional Support Bracket pic 5 can be ordered to stack multiple or a mix of CPUs and UPSs Measure the height of the piece that will sit in the bottom support to determine where the height of the additional support will be located 4 The Accessory Pack pic 3 also contains rubber leveling bumpers Normally 3 large ones spaced evenly on the outside support ledge will adjust the CPU to level pic 4a pic 5 eisys healthcare 20 rev 11 4 2010 7 1 GMZC6 SPE INSTALLATION e After assembly of the GMZC6 if necessary install the GMC
7. g plate Pre drilled holes should allow this Position control panel mounting plate at pre marked holes pic 6 This bracket allows the control panel to slide approx one inch front to back Place control panel on top of mounting slide plate and position control panel so that when slid to front of plate the panel is flush with front edge of table top Fasten with supplied 3 Phillips head screws using 1 Phillips bit ONLY pic 7 Note Caution should be used not to strip the 1 Phillips head screw CAUTION DO NOT OVER TIGHTEN CONTROL PANEL WILL NOT SLIDE 1C Pencil Tray e Use the 2 holes located on front edge of top the opposite side from the control panel see Pic 8 CAUTION IS NEEDED AS TO NOT OVER TIGHTEN SCREWS OVERTIGHTENING SCREWS MAY CAUSE THEM TO PUNCTURE LAMINATE ON DESK SURFACE eisys healthcare 14 rev 11 4 2010 1 PREPARING TABLE TOP cont 1D Cup Holder e Attach cup holder at pre tapped holes on the un der side of top left or right corner with supplied 3 3 4 Phillips head wood screws Note Preferable location is the opposite side of the CPU placement pic 10 1F User s Manual e User manual is located in the Frame Box Pic 11 e Remove film backing from packet and apply packet on underside of table where indicated in pic 12 eisys healthcare 15 rev 11 4 2010 2 MOUNTING RAIL POSTS CAUTION Rail and Rail Accessories can not be installed until table
8. ght posts 2 w clamps 4 5 Allen Head screws F Power cable D 2 Switch and cable G Black Nylon Knurled Screws for Light Shield Tension 2 not pictured eisys healthcare 22 rev 11 4 2010 8 2 Position lamp in post ends e Pic 1 Insert lamp ends into posts until seated e Pic 2 Shows lamp correctly seated pic 1 8 3 Attach support posts to rail e Attach light posts using the bottom clamps and Allen bolts finger tight e Feed lamp power cord through rear slot in clamp Standing behind the desk the cord should come through the left post Mount swivel clamps so that posts can be mounted in any location on a corner desk with a curved monitor rail NOTE Light post should be centered and vertically straight pic 1 eisys healthcare 23 rev 11 4 2010 8 4 Mounting the ballast housing e Desktop Mounting Use the supplied 4 wood screws Locate the 4 predrilled holes centered just forward of the rear triangular tube Pic 1 Attach ballast here e Cable Tray Mounting for Generation II Cable Trays only pic 1 Use the supplied 4 bolts and thumbscrews Insert in the 4 holes located in the bottom of the cable tray Tighten Pic 2 8 5 Attach power switch to desktop e Locate the two pre tapped holes under desk top and to the right of control panel e Attach switch box to bottom of desktop with two 2 1 3 4 wood screws provided Pic 1 Switch box sho
9. he piston rod to secure pic 1 e Center gas spring with stabilizing plate into column and align plate with 4 screw holes e Mount the plate pic 2 using the four 4 Torx head countersunk screws and Torx25 tip Tighten screws evenly to compress cylinder until plate is flush with leg column Note Tighten screws slowly in an alternate pattern making sure plate compresses evenly eisys healthcare 8 rev 11 4 2010 7 ATTACHING TABLE TOP NOTE IF THE MODEL NUMBER ENDS IN Z OR ZM AFTER THE GAS SPRINGS ARE INSTALLED THE FRAME HAS TO HAVE APPROXIMATELY 88 LBS OF WEIGHT ADDED WHILE RAISING OR LOWERING THE TABLE ASSEMBLY TO ADD WEIGHT LEAN ON FRAME EXERTING APPROXIMATELY 88 LBS OF PRESSURE WHILE PRESSING AND HOLDING THE UP OR DOWN ARROW CAUTION FAILURE TO DO THIS MAY DAMAGE MOTOR OR GEARS e Align frame with top support structure and attach columns to top pic 2 with pic 3 with supplied 8 4 Allen head bolts 4 per column Note When table top and columns are aligned the two plates will be flush Jobsite Conditions A If you are assembling the workcenter in the room where it will reside you can assemble the entire unit upside down and then place right side up B If you are assembling the workcenter outside of the room where it will reside the control panel cannot be attached to the top until the table top and leg assembly are placed in the final room location eisys healthcare 9 rev 11 4 2010 O
10. n 68cm 26 75 Each mark represents one 1 cm Total range is 10 cm or 4 Be careful to line up all four feet to the same number as to make sure the workcenter is level pic 4 eisys healthcare 6 rev 11 4 2010 4 RESETTING THE CONTROL PANEL e Keeping frame upside down plug desk in You will see blinking zeros on the control panel pic 1 e To reset the control panel press and hold the down arrow button until column reaches its lowest position Continue to press the down arrow until diplay reads 067 or 068 The workcenter controls are now reset NOTE You cannot raise the table until you reset pic 1 the column at Its lowest position YOU ARE NOW READY TO RAISE THE TABLE ASSEMBLY USING THE UP ARROW e Extend the leg columns completely by pressing and holding the up arrow until top reaches 120cm shown on display pic 3 e Remove the cover stabilizing plate on the foot side of the column by loosening the four 4 coun ter sunk screws pic 4 THE COLUMNS HAVE TO BE COMPLETELY EXTENDED BEFORE INSTALLING GAS SPRINGS BECAUSE OF THE RISK OF INJURY BY THE PRESSURIZED GAS pic 4 eisys healthcare 7 rev 11 4 2010 6 INSTALLATION OF GAS SPRINGS not appliciable if factory installed pic 1 pic 2 e Align the stabilizing plate with the piston rod of the gas spring side of the plate with countersunk holes facing away from spring Plate has to be rotated clockwise on t
11. top is attached to leg assembly and placed upright e Post should be mounted on table top with 4 supplied 6mm allen head bolts e Place one full washer on table top surface and the second half washer on the underside of the table top Pic 2 and Pic 3 Note DO NOT tighten posts completely until rail is positioned on posts step 2 pic 1 pic 2 pic 3 3 MOUNTING RAIL e Pic 1 shows position of installed rail and posts NOTE Rail may be mounted in front or behind support posts CAUTION Loosen 2 5 mm allen screws A pic 2 and the 2 mm allen screw B pic 2 so that pic 1 they are recessed from the inside of the rail collar or damage to post could occur Slide rail down evenly over rail posts so that the bottom of rail collar is even with the 2nd to last ring at the bottom of post approximately 10cm from work top Note The rail height is determined by the size and style of monitors A good starting position is to place the collar at the second ring from the bottom of the rail posts approximately 10cm from the work top It is also important to position the rail collar on one of the post rings so the set screw A in Pic 3 will fully tighten on the post Tighten set screws carefully not to over tighten Once rail is positioned on post finish tightening the bolts securely on the post under the top step 1 eisys healthcare 16 rev 11 4 2010 4 MOUNTING RAIL ACCESSORIES NOTE Pic 1 shows how the
12. tor eisys healthcare 18 rev 11 4 2010 O E eee 5 MOUNTING TABLE TOP ACCESSORIES pic 1 pic 1A pic 1b e Remove organizational hole cover pic 1 1A Remove cap amp sleeve of org hole Position Desk Fixing Post w full washer over org hole Insert bolt and small washer from under desk into top with 300 mm post Appllicable with 1B Telephone Post Holder 1C Paper Tray Note Org sleeve does not need to be removed 1D LCD Arm Manual Height Adjustment _CD QRE DF INSTALLATION NOTE Paper tray and Advanced LCD Height Adjustable Arm can also be mounted to the desk top with optional desk clamp NOTE Step by step installation of triple paper tray in box Desk Edge Clamp not applicable when using org holes 6 MOUNTING POWER DOME e Remove gromet hole cover e Insert wires of power dome through grommet hole pic 1 e Slide both halves together and place in grommet hole until flush with desk top pic 2 pic 2 eisys healthcare 19 rev 11 4 2010 7 CPU LINE CONDITIONER INSTALLATION e The GMCZ 6 comes with one connecting column and one Support Plate for complete set up pic 1 1 Determine the width of your CPU case Loosen the two black thumb screws on the side to extend the standard support plate but do not extend beyond the thumb screws If the CPU is wider than 5 1 4 then you will need to add the extensions that come stored under the support bracket This will give you a maximum width o
13. uld be flush with front edge of top e Manage wires with provided wire clips pic 1 eisys healthcare 24 rev 11 4 2010 Contacts General Manager Dick Gardner p 205 329 7053 dick gardner eisys inc com Project Management Technical Assistance Tim House p 205 329 7054 c 205 937 0911 tim house eisys inc com Technical Assistance Alex Corona p 205 329 7055 alex corona eisys inc com forward thinking solutions gt healthcare gt education gt office dpi ah o 888 941 1942 info eisys inc com office f 205 941 1781 www eisys inc com eisys 112 28th Street South Birmingham Alabama 35233
14. unted to the Generation II Cable Tray using the MBMOU mounted to the slotted door of the cable tray e Mount in cable tray as seen in pic 2 and in Generation II as seen in pic 2A Use plastic thumbscrews to secure pic 2B pic 2A pic 2A e Mount 6 Duplex Multi Outlet strip in Generation II cable tray as seen in pic 3 Use screws to secure pic 3B iN WO AG AN A o ANAS AN 5 A Y AA 2 Duplex 4 Duplex 6 Duplex with Generation II Cable Tray no MBMO U required eisys healthcare 12 rev 11 4 2010 1A 1 Cable Tray Generation pic 3 pisas pic 5 e Position cable tray as seen in pic 3 and pop tray into place by slide lip of cable tray under triangular tube e Use mounting brackets 2 Pic 4 and nut bolts to secure tray to triangular tube Pic 5 1A 2 Cable Tray Generation Il pic 8 pic 6 e Center cable tray over triangular tubes with the hinged door facing toward the rear of desktop Pic 6 e Center cable tray left and right of desktop Pic 7 e Attach using the 3 4 wood screws Pic 8 eisys healthcare 13 rev 11 4 2010 ee ee 1 PREPARING TABLE TOP cont 1B Preparation for the Control Panel Note The control panel cannot be installed or secured to the top until top is mounted to the frame and workcenter is in its final location Be sure control panel cable comes from behind and over cross rail Locate the pre marked holes for the control panel mountin