Home
User Manual for SNMP NetAgent
Contents
1. Server 192 168 50 179 User Name Anonymous M Use Copy To Folder on the File menu to download files and folders to your computer Click here for other useful hints la Internet Astar A E E Siep 77192 168 50 179 Ey 542PM 100 Appendix B 3 Ports NetAgent ll with SMS Modem BP506 amp SMS MODEM Hardware Installation 1 GSM MODEM GSM MODEM Adaptor NetAgent BP506 GSM MODEM Cable RS232 to RJ45 Cable A B C D E 2 How hardware should be connected 4 Once card inserted Modem would detects if such SIM card has password and the signal with its ISP If Led flashes every second continuously there is no signal been received OR SIM 101 card has password invalid password If such conditions happens please unplug amp plug the power on Modem and it shall ready SIM again If Led doesn t flash continuously once every 8 seconds then Modem is working properly 102 BP506 Modem Configuration 1 BP506 Modem 2 Modem communication Type Select SMS 3 SMS Communication Select GPRS 4 Enter SIM Card PIN leave blank if none 5 Click on Apply NetAgent E Information Modem Settings Modem Communication Type ems SM WMS Settings SMS Communication SIM Card PIN 4 Confirm SIM Card PIN 5 Configuration Ail eee un SSS Pea ae iar number anad message conten ELLA
2. 3 5 NetAgent Mini OutLook NetAgent Mini External NetAgent Mini Internal Module To UPS Status LED To LAN LAN Port LED To DC adapter To LAN Status LED LAN Port LED Light signal application of NetAgent Mini Status LED Light color Signal definition Condition description Red Connection state with UPS Flash no connection with UPS Light flashes when Netagent transmits Correspondence state commands BS Light signal application of NetAgent Mini LAN Port LED Light color Condition description Green On Internet correspond speed is 100M Flash Data transmmiting On Internet correspond speed is 10M Yellow M Flash Data transmmiting Fig 3 NetAgent Mini Out looking Section4 NetAgent9 Models 4 1 NetAgent 9 Models NetAgent 9 Model Package Content Internal External 1 3Ports 1 3Phase 1 3 Ports External Agent 2 NetAgent Utility CD 3 User Manual 4 M2501 Cable for Contact Closure UPS External 5 M2502 or M2505 Cable for RS232 UPS M2506 Cable for Modem 9V DC adapter 3 Port Internal card o NetAgent Utility CD 3Ports Internal User Manual M2506 Cable for Modem 1Port External card NetAgent Utility CD 1 3 Phase User Manual 4 M2501 Cable for Contact External Closure UPS 5 M2502 or M2505 Cable for RS232 UPS Adaptor 1Port Internal card NetAgent Utility CD User Manual Internal NetAgent Mini NetAgent Utility CD User Manual Internal NetAgent Min
3. When Connection should be made Disabled v Login Name Login Password System will reboot when these items have been Applied Fig 29 Network 38 2 2 4 Wireless This is to configure Wireless network with USB wireless dongle This feature only apply to NetAgent 9 model of BX series USB wireless dongle is optional NetAgent 9 BX models supports wireless encryption of Open system Shared Key WEP 64 128 bit WPA WPA2 TKIP AES Following is the wireless configuration Setup was done under Lan network Click on Configuration Wireless Search AP and select the wireless SSID station and click on Select E i NetAgent Il 31ll gen CERT Configuration gt Wireless z la a a l a a Search AP Configuration Hefault 00 13 D4 D1 FE 68 O ken test 00 13 D4 D1 FC EE O MegaTec 00 27 19 3E C0 72 O TelTel Hinet AP 00 1C F0 C5 BF 7B daniel_ap 00 1D 60 E4 A2 A3 Wi Log Information Fig 30 NetAgent 9 Wireless Click on access Point enter the encryption configuration and password then click on Apply E as NetAgent Il ll g Information Configuration gt Wireless Iz SCIES a Gla Access Point BETIS iE a Configuration UPS On Off Schedule l Authentication Shared Keys WPA Encryption TK Wireless 53 WPA Key Sto64characters jessssssesss WEP Encryption 64 bit Key M WEP Key 10 or 26 hex
4. AA AAAA 1 Fig 56 Serial ports debug 2 4 3 Help This to help to illustrate the operation of NetAgent 2 4 4About About This to check Netagent s Firmware Hardware version and serial number Save Restore Settings Click Save to save the configuration to your PC The text file will have a default format of YYYY MMDD_ cfg Administrator permission required Restore previous configuration Use this function to restore a cfg configuration that has been saved earlier Click Browse to the location of the file and click Restore Reset to factory default This function will reset all settings to its default value Firmware Update Setting Default FTP server is set as ftp icv99 com with its username password Click on Update Now NetAgent will connects to the FTP server and upgrade to the latest firmware version accordingly Auto Update This is to configure the period of time to check if any updated firmware in FTP and upgrade automatically Firmware Update When click it links to http AWwww megatec com tw Download htm NetAgent to download the available firmware Firmware Version 2 42 BP50b5 Hardware Version HBP506 Serial Number 3926048366 Save current configuration Restore previous
5. NetSwitch BT series only When BT NetAgent connects with NetSwitch on RPM it able to perform action to the specific outlet when following event or alarm triggers 47 Events 1 UPS Load 2 UPS Communication 3 AC Power Overrun Lost Failed 4 UPS Battery 5 UPS Temperature 6 When battery Overun capacity reaches to NetFeeler Il environmental sensor 1 Temperature Overrun 2 Humidity 3 Water Underrun Overrun Underrun 4 Smoke 5 Gas 6 Security Door Windows 1 7 NetSwitch Setting Select NetSwitch To select the NetSwitch Address Change RPM could be daisy chain up to 16 units to control a total of 128 devices Use this to assign a new number or change the currently assigned number for the RPM unit You have a choice of 00 to 16 Note You cannot choose a number that is already assigned to another RPM Identification To give a unique name for the RPM Outlet Indicate outlets A H Name To set a unique name for the Outlets Phone Controllable Option of Yes or No Control type Select between Instant Shutdown Safe Reboot Safe Shutdown Power off Delay Sets the power off delay time in seconds value from 0 to 9999 Power Resume Delay Sets the power resume on delay time in seconds value from 0 to 9999 Modem Settings Modem Communication Type SMS Communication GPRS v SIM Card PIN Confirm SIM Card PIN Heceiver cellular number and message content Cellular
6. ORION Power Systems NetAgent UPS SNMP Agent User s Manual Contents Chapter1 Introduction Section1 Features Section2 Applications 2 1 NetAgent makes your UPS on the Internet 2 2 NetAgent Provides Shutdown Utilities 2 3 NetAgent II for Surrounding Monitoring 2 4 When we need the NetAgent Section3 NetAgent Models 3 1 NetAgent Models 3 2 Pictures of NetAgent Il 3 3 NetAgent Package Contents 3 4 NetAgent ll Outlook 3 5 NetAgent Mini OutLook Section4 NetAgent9 Models 4 1 NetAgent 9 Models 4 2 Pictures of NetAgent9 4 3 NetAgent 9 Package Contents 4 4 NetAgent 9 Outlook 4 5 NetAgent 9 Mini Outlook Chapter 2 NetAgent UPS Installation Chapter 3 NetAgent UPS and Network Connection Section1 Install the NetAgent Il with UPS and Network 1 1 For External NetAgent Il 1 2 For Internal NetAgent II Section2 Install the NetAgent Mini with UPS and Network 2 1 For External NetAgent Mini 2 2 For Internal NetAgent Mini Chapter 4 Using Netility Setup IP Update Firmware Section1 Install Netility Section2 Using Netility Chapter 5 UPS Web management by NetAgent Section1 Introduction O N NORA A m NNNN zub A A Li come A N N CO OO o c o o o l N NN N N S n N N Oo O O Section2 NetAgent UPS Web Interface 2 1 Information 2 1 1 System Status 2 1 2 Basic Information 2 1 3 Current Status 2 1 4 Remote Control 2 1 5 Meter Chart 2 1 6 Modem Status For 3
7. French gt Italian gt Turkish gt Russian gt Polish 56 2 3 Log Information Sub Menu 2 3 1 Event Log 2 3 2 SMS 2 3 3 Data Log 2 3 4 Save Data Log NetAgent Log Record Log Information Single Port Single Port DP CP DT CT CX DX Gba EX DDUIEAS Event Log 100 logs 1000 logs 1000 logs UPS data Log 500 logs 5000 logs 5000 logs Fig 50 NetAgent Log Record 2 3 1 Event Log This page is a UPS Event log It shows a record of all events giving the Date Time of the event and a detailed description of each When reach to the limit it rewrites on the previous logs Date Time This is a record of the Date yyyy mm dd and Time hh mm ss that the event occurred Event This is a detailed description of the event Save This is to save the event log o 2007 03 17 16 23 11 2007 03 17 13 22 30 2007 09 17 10 17 10 2007 03 17 07 16 31 2007 03 17 04 14 31 2007 08 17 01 13 11 2007 09 16 19 10 31 2007 03 15 16 03 51 2007 03 16 13 07 51 2007 03 16 07 05 52 2007 08 15 04 02 32 2007 09 16 01 01 52 2007 08 15 21 57 12 2007 09 15 18 47 12 2007 09 15 15 43 12 2007 03 15 12 41 52 2007 03 15 09 41 12 2007 03 15 06 33 53 2007 03 15 03 35 13 2007 09 15 00 33 13 2007 03 14 21 31 53 2007 09 14 18 27 13 2007 09 14 15 23 53 2007 03 14 06 22 33 2007 03 14 03 17 13 2007 03 14 00 08 33 2007 08 03 19 30 42 2007 09 03 15 33 02 2007 09 03 13 37 23 2007 03 03 10 35 23 2007 03 03 07 34 03 The TimeServer connection f
8. SMS to be sent and received using a GSM GPRS CDMA Modem Operation information are as below for single and three ports of NetAgent 2 2 6 1 To send SMS by single port of NetAgent It requires to use remote S5MSAgent or freeware SMS Server SMS Settings Send SMS when Event Occurs This section is to select if use local modem or remote service to send SMS Select local modem when modem connects with 3 Ports NetAgent Select remote service if modem connects to PC using SMS Server software or connects with SMSAgent Select Disable if not needed SMS Server SMS Server Port This section is to set the IP address of the SMSAgent or PC if selected remote service e g 192 168 0 180 and Port Number default 80 Account Name Password This section is to enter SMSAgent s account and password if configured SMSAgent webpage Configuration Web Telnet Leave blank if no such setting Receiver cellular number for Event Log This section is to set the recipients mobile number A total of 8 mobile numbers can be assign Selectable events list is same as SNMP webpage Refer to page 35 figure 31 UPS Event Note 1 Enter mobile number same as sending from mobile Note 2 Please refer to SMSAgent s user manual for further information Note 3 See Appendix for further information INS ES o HT Sigs D T EEE send SMS When Event Occurs ohlS Server fiszt68 01 SMS Server Part eos sending test SMS DO OE Cellu
9. Smart APC EMERSON User could also provide their own protocol to build in NetAgent provides a simple and easy installation procedure CD provides along with NetAgent offers several softwares to allow the user to configure IP address central monitoring and multi shutdown on different operating systems Other advance configurations could be accomplished in the Web browser Features Provide SNMP MIB to monitor amp control UPS O Auto sense 10M 100M Fast Ethernet Manage and configure via Telnet Web Browser or NMS O Support TCP IP UDP SNMP Telnet SNTP PPP HTTP SMTP Protocol Providing easy setup and upgrade tools via MS Windows just a few seconds to finish IP setting about 1 5 minutes to upgrade firmware Send SNMP TRAP E mail and SMS for events notification Auto email daily UPS history report Matches with shutdown software to protect computer s file saving and shut down safely NetAgent ll 3Ports Environment Measurement Optional Kits External modem dial in out via PPP protocol or GSM GPRS Modem Section2 Applications 2 1 NetAgent makes your UPS on the Internet When the UPS connects with NetAgent the system manager could check each and every UPS condition by a computer with Browser installed The manager could monitor and control the UPS by simply input the IP address of the NetAgent which connects to the UPS When there is a power abnormal condition happens the NetAgent could also send the
10. mode your browser must be able to access to the Internet Input Volt V Output Volt V Tem perature C Load Fig 24 NetAgent 9 Meter Chart 2 1 6 Modem Status For 3 Ports NetAgent Il only This page displays Modem s status and information when 3 ports NetAgent II connects with modem Modem Information This section displays the modem information GSM Modem Operating Status This section displays the operating status between NetAgent and Modem Modem Information Modem Manufacturer SIEMENS Modem Model TC 35i Modem Firmware Version REVISION 02 07 GSM Modem Current Status Service Provider Central number of SMS service signal strength 96 SIM card PIN is correct or not No SIM card detected Fig 25 Modem Status 2 1 7 Environment Sensors NetFeeler Il 3 Ports NetAgent could be connected to NetFeeler ll to detect the environmental status NetFeeler is to detect Temperature Humidity and Water It can receive signals from wireless smoke sensors gas sensors and security sensors to detect further environmental conditions This page is to show details of the environment detected by NetFeeler II Users could choose an interval from the drop down box to refresh the status All settings can be set in the Configuration NetFeeler Il page The status will be displayed in red when NetFeeler II detects an abnormal status condition In addition NetFeeler II will also set off an alarm for
11. 0 132 168 2008 5 0 0 132 168 2008 5 2084 132 168 2008 5 0 0 132 168 2008 5 0 0 132 168 2008 5 2084 192 168 2008 5 0 0 132 168 2008 5 0 0 132 168 2008 5 208 4 199 1c0 anno Ie an 94 we seee ceee ceee ceee ceee seee ceee seee ceee ceee ceee seee ceee ceee ceee seee ceee ceee D a seee ceee seee seee seee ceee ceee seee ceee ceee seee seee ceee ceee ceee seee seee seee seee seee seee ceee seee seee QD OOo i 7 Onti parameter plions D eee 95 5 5 User U Total of 8 users account can be created to manage and control its NetAgent UPS 5 5 1 Change Password To change existing user s Chan e Password password to login ange ae UO This only for Admin user to add edit or remote other user s info User Management Sse tna 96 5 6 Help H Display the current SNMPView version and operation information 5 6 1 HTML Help This to check the operation of SNMPView A io ERRE H A 3 BR Sl WAO ASO mela 30 isl Installation Megalec Megatec Softwar e qo Using SNMPView eee s SNMPView Buttons Using SNMPView Enumerate Z Add UPS After the SNMPView program start up the main windows will be Delete UPS E displayed The left panel will list the available stations by area E Group and the right pa
12. 0 53 9 i 100 320C 69_6F 2007 09 17 16 36 04 112 0 112 0 59 9 100 320 83 6F 2007 09 17 16 35 03 113 0 113 0 59 6 i 100 320C 83 6F 2007 09 17 16 34 03 113 0 113 0 58 8 i 100 32 0C 89 6F 2007 09 17 16 33 03 113 0 112 0 59 9 0 100 32 0C 89 6F Fig 53 Date Log 61 2 3 3 Save Data Log This function is to record RS232 UPS s voltage frequency load capacity temperature etc to save as another file for the other purpose to the manager File Download Do you want to open or save this file xD Name upsdata csv Type Microsoft Excel Comma Separated Values File From 192 168 0 167 gt While files from the Internet can be useful some files can potentially e harm your computer IF pou do nat trust the source do not open ar save this File What s the risk Fig 54 Save Data Log 62 2 4 Help Sub Menu 2 4 1 Search NetAgent 2 4 2 Serial Port Debug 2 4 3 Help 2 4 4 About 2 4 1 Search NetAgent This to display all the found NetAgent within network with its serial number Mac Address Hardware Firmware version and its IP address Double clicking on the highlighted unit to open the webpage of such device Browse NetAgent MAC Address IP Address 3925954004 00 03 EA4 01 4D D4 HDP520 2 40 UI5 9c09 192 168 0 166 3325955343 AE DP520 2 41 DP520 192 168 0 156 3926054176 00 03 EA 02 D5 20 HCP504 2 42 CP504 3926120052 00 03 EA 03 D6 74 HCV 3 2 55 CV73 192 158 0 32 3925181499 DD 03 EA 04 CB 7B HCV73 2 55 CV73 19
13. 42 BPS506 UPS Next Self Test Serial Number 3825049227 UPS Critical Load Bl 6 System Name UPS Agent UPS Critical Temperature POLES System Contact Administrator UPS Critical Capacity 10 Location My Office System Time 2005 1 1 05 07 33 48 Uptime 00 00 42 Warning will be initiated 10 minute s before Scheduled Shutdown Event Send Email for Daily Report Ma MAC Address 00 03 EAD CT CB Primary DNS Server 160 95 1 1 Connection Type 100Mbps Full Duplex Secondary DNS Server 166 95 192 1 IP Address 1832 158 1 155 Time Server time nist gov Subnet Mask 255 255 255 0 PPPoE IP Gateway 192 165 0 1 PPP Server 10 0 0 1 Email Server Login IP 10 0 0 2 Fig 18 System Status 2 1 2 Basic Information This page is to show UPS basic information Values here are either provided by the UPS or they are user settings from the Configuration pages UPS Information Information about UPS Manufacturer UPS Firmware Version UPS Model are provided by the UPS Battery Information Values here are user settings from the Configuration pages Rating Information Values here are provided by the UPS UPS Information UPS Manufacturer LIPS Firmware Version VEO UPS Model SCOBPBOS Battery Information Date of last battery replacement Number of Batteries 2 Battery Charge Voltage 2 267 Voltage Rating 115 04 Frequency Rating BU OHz Battery Voltage Rating 12 04 Fig 19 Basic Information 2 1 3 Current Status This page is to show the UPS curre
14. 6 AC Status 2 7 Battery Status 2 3 Evert Log 2 8 Time Remainto shutdown 2 9 Connection Log 2 4 About 69 2 1 Config When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals the ClientMate will based on the configuration below to initiate the shutdown process The details of the configuration are here below Configure E General Power Failure Schedule Shutdown Hast Connection O CNMP YA User Mame Connection Query Password SNMP Y3 Available List Authenticate MDE N 192 168 0162 t UPSilon AUPS Privacy ES N 192 168 0 170 Host 192 168 0 162 Quen T SNMF port 1 6 Community public W arning Messages Broadcast Warming Messages Un Server platform i Popup warning Message Configuration Password Refresh Cancel Password Confirmed Password Cancel Fig 63 ClientMate Configuration General i Host Connection This is to configure how ClientMate connects with NetAgent NetAgent 9 or UPSilon RUPS 2000 SNMP V1 V2 This is default to connect with NetAgent or NetAgent 9 SNMP V3 This only use on NetAgent 9 NetAgent 9 uses SNMP V3 protocol to connect with ClientMate When select such communication it requires to enter username password and appropriate authentication and privacy SNMP V3 configuration may refer to SNMP of the NetAgent UPSilon RUPS To connect with UPSilon or RUPS server by e
15. BEP A non internet or A non internet MEE A non internet one A non internet BE W All On All Off EN Fig 41 NetSwitch Status 49 NetSwitch Action This is to configure the action on specific event when occur NetSwitch would executes the action per setting as to turn on or turn off on the assigned outlet Click on New to select event and set action NetSwitch Action No Events Events Action NetS witch Outlet Outlet Action Modify Z htip 192 168 0 162 RPM_Action htm Microsoft Intenet Explorer ma Events Select feon UPS Events Action Occur O Remove NetSwitch Qutlet Outlet Action OON OOFF Fig 42 NetSwitch Action 2 2 9 WEB Telnet This page is to set up the User Account in NetAgent User Account User Name This section is to set a user name for NetAgent web pages It is valid for up to 8 users Users have to input the user name to get access to NetAgent web pages from a web browser Password This section is to set a password for NetAgent web pages Users have to input the password to get access to NetAgent web pages from a browser Permission This section is to set user s authorizations of Read or Read Write IP Filter This section is to set a particular IP address Users can only gain access to NetAgent web pages if they come from this IP address If you want to manage NetAgent from any IP address you can set it as RADIUS Server Settings This is to configure the param
16. Icons 5 2 2 Small Icons 5 2 3 Details 5 2 4 Map Background 5 3 Tools P 5 3 1 Settings 5 3 2 UPS Monitor 5 3 3 UPS Management 5 4 System S 5 4 1 Event Log 5 4 2 Data Log 5 4 3 SNMP Option 69 69 70 12 73 73 73 74 74 74 T9 75 75 76 77 78 80 81 81 82 83 84 84 85 85 85 86 86 8 8 90 93 94 94 94 95 5 5 User U 96 5 5 1 Change Password 96 5 5 2 User Management 96 5 6 Help H 97 5 6 1 HIML Help 97 5 6 2 About 97 Appendix A Update the firmware of NetAgent UPS 98 Appendix B 3 Ports NetAgent Il with SMS Modem 101 Appendix C SMS Server with SMS Modme 105 Chapter1 Introduction Section Features NetAgent is a new generation SNMP Simple Network Management Protocol monitoring product Not only could remote control the UPS and get the current status of it the NetAgent Il 3Ports also could provide other functions ex connect to Modem or GSM Modem to make the monitoring possible when there is no permanent connection to Internet and sens SMS notification The NetAgent II 3Ports could also been used to connect to NetFeeler Il to get the temperature humidity and water conditions To get the condition of Smoke detector Gas detector door and window detector are also possible This product is for Contact Closure and RS232 interface UPS The communication protocol includes the Contact Closure RS232 MegaTec RS232 Phoenixtec SEC 2400 SEC 9600 Three Phase Powerware
17. Off Parameters e Turn Off Delay To set the buffering time for UPS before shutdown e Sleep Time To set UPS sleep time Test Period e Unknown This defined by UPS configuration e Two weeks Perform UPS test every two weeks e Weekly Perform UPS test every week e Disable Do not perform UPS test 92 5 3 3 UPS Management To configure SNMP of its NetAgent UPS UPS Management UPS upsBaseldenth odel UP SIdent upsBaszeldentupsM ame Basic UPS pupsBaseldentMadel fee p aseldentupsh ame H Smart UFS E UFS Battery E LUPSInput E UPSDutput 93 5 4 System S To view event log data log and configuration 54 1 Event Log Display event log date time and Record List d escri pti O n of al 192 168 1 144 2008 5 26 13 9 11 imm the communication with the UPS NetAgent UPS Save As Piint Clear AII PEREOS aJ d U 542 Data Log output voltage Record List frequency load etc UPS HostNa Startup Input V Output Batte Capacity Loading Temper Frequen 132 168 2008 5 2084 of all NetAgent UPS 192 168 2008 5 0 0 132 168 2008 5 0 0 132 168 2008 5 2084 132 168 2008 5 0 0 132 168 2008 5 0 0 192 168 2008 5 2084 192 168 2008 5 0 0 132 168 2008 5 0 0 132 168 2008 5 208 4 132 168 2008 5 0
18. Ports NetAgent II only 2 1 7 Environment Sensors NetFeeler l 2 2 Configuration 2 2 1 UPS Configuration 2 2 2 UPS On Off Schedule 2 2 3 Network 2 2 4 Wireless 2 2 5 SNMP 2 2 6 Email 2 2 SMS 2 2 8 Modem For 3 Ports NetAgent II only NetSwitch Status NetSwitch Action 2 2 9 WEB Telnet 2 2 10 System Time 2 2 11 NetFeeler Il For 3 Ports NetAgent II only 2 2 12 Language 2 3 Log Information 2 3 1 Event Log 2 3 2 SMS 2 3 3 Data Log 2 3 3 Save Data Log 2 4 Help 2 4 1 Search NetAgent 2 4 2 Serial Port Debug Chapter 6 Telnet Remote Configuration Section1 Introduction Section2 Telnet Configuration Section3 Telnet Configuration Chapter 7 ClientMate Windows Shutdown Utility 2 22 24 25 25 26 27 29 30 31 32 33 35 36 39 40 44 46 47 49 50 50 52 54 55 57 57 59 60 62 63 63 63 66 66 66 68 69 Section1 Install ClientMate Section2 Using ClientMate 2 1 Config 2 2 Closed Files 2 3 About 2 4 Event log 2 5 IP address of connection 2 6 AC power status 2 Battery Status 2 8 Status History Chapter 8 SNMPView Windows Based UPS Management System Section1 Introduction Section2 System Requirements Section3 Install SNMPView Section4 Using SNMPView Section5 SNMPView Buttons 5 1 ENUMERATE D 5 1 5 Browse Device 5 1 6 Export Configuration 5 1 7 Import Configuration 5 1 8 Open archive Event Log 5 1 9 Open archive Data Log 5 1 10 Quit 5 2 View S 5 2 1 Large
19. System for Every D Disable 0 Minute s v Manual Restart System After 30 Seconds Fig 46 System Time W as NetAgent Il 3ll g Configuration gt System Time Configuration SACE C a Backup Time UPS Configuration l Time Between Log Backup v Fig 47 NetAgent 9 System Time 2 2 11 NetFeeler Il For 3 Ports NetAgent Il only This page is to set Environmental sensors NetFeeler II s configurations NetFeeler II Critical UnderRun This section is to set the lowest critical values for temperature and humidity NetFeeler ll will send a warning message when it detects temperature or humidity values below these settings 54 Critical OverRun This section is to set the highest critical values for temperature and humidity NetFeeler ll will send a warning message when it detects temperature or humidity values above these settings Security Label NetFeeler l may connect up to 7 security sensors This section is to set the location of searched sensor NetFeeler Lite Critical UnderRun Critical QverRun Humidity 5 E a Temperature CJ 5 0 ran Security Label Label 1 Security Status Label 2 Security2 Status Label 3 Security3 Status Label 4 Security4 Status Label 5 Becuitys Status Label B Security6 Status Label Security Status Fig 48 NetFeeler II 2 2 12 Language This page is to set the language interface for NetAgent Interface Language This section is to set the language f
20. UPS Agent Administrator My Office Manager IP Address Community Permission Description ius public Read Write Y yog public No Access phe public No Access Y jid public No Access pd public No Access Au public No Access Y id public No Access Y peg public No Access rap Notification Destination IP Address Community Trap Type Severity Accept Description Events public PPC m Information No public PPC v Information No public PPC v Information No public PPC Information No public PPC v Information No public PPC v Information No public PPC Information No w Test public PPC v Information No M Device Rating 96 Connected 0 NO 0 NO 0 NO D NO SNMP UDP Port NetAgent SNMP Port Trap Receive Port 161 162 System will reboot when this item has been Applied Fig 34 SNMP E Tr NetAgent IX CE os Configuration UGH Access Control Be Mo i EU png B 34 Ser n TS CT ES OP a T Tu Manager IP Version Community Permission User Name Password Authentication Privacy Description Address public ReadMWrite w SHA v DES wv public No Access MDS v DES wj SNMP amp 3 public j Mo Access w MD5 i DES i 563 S public NoAccess i MDS ua DES iv public No Access MD5 DES v public Mo Access w MD
21. Yl gen CE p Configuration System Information II S774 1 TG Log Information Hardware Version HCX504 UPS Last Self Test e Firmware Version 3 0 CX504 UPS Next Self Test Serial Number 3925858555 UPS Critical Load 8D System Name UPS Agent UPS Critical Temperature 70 0 C System Contact Administrator UPS Critical Capacity 10 96 Location My Office System Time 2010 12 09 16 54 58 Uptime 00 06 06 Warning will be initiated 10 minute s before Scheduled Shutdown Event Send Email for Daily Report No Fig 17 NetAgent 9 2 1 Information Sub Menu 2 1 1 System Status 2 1 2 Basic Information 2 1 3 Current Status 2 1 4 Remote Control 2 1 5 Meter Chart 2 1 6 Modem Status 2 1 7 Environment Sensors NetFeeler Il 24 2 1 1 System Status This page is to show NetAgent system information and Network settings Values shown here are either provided by NetAgent itself or they are user settings from the Configuration pages System Information This section is to show NetAgent system information Values in Hardware Version Firmware Version Serial Number System Time are provided by NetAgent itself Other values are user settings from the Configuration pages Network Status This section is to show NetAgent Network settings The MAC address is provided by NetAgent All other values in this section are user settings from the Configuration pages Hardware Version HBFSIIB UPS Last Self Test Firmware Version 2
22. are going to upgrade firmware click Download Firmware from NetAgent Setup menu click Browser select new firmware file bin and press Start Thus Net Agent s Red LED and Yellow LED flashing alternative means the firmware is upgrading After upgrade completed Net Agent will auto reboot To upgrade multi NetAgent with same firmware hold on shift or Ctrl and choose the NetAgent device from Netility list Please connect to the http wWwww megatec com tw for the latest firmware If multi upgrade select When upgrade firmware to multi NetAgent Note Net Agent provided well considerable protection function 1f uploading was interrupted and raised data in incomplete Net Agent will keep its default to avoid of complete data loss In the case just repeat firmware upload as well Firmveare Download Eilename D Spic 2 40 CP504 bin Download Status 3926030532 3926031045 Download Cancel Fig 11 Netility Update NetAgent UPS firmware O About Netility version examined About Netility 5 Metility 4 5 Copyrieht 7 2001 2010 Mega System Technologies Inc Fig 12 Netility version examined Refresh List e Refresh List Search Lan s Netagent UPS manually s Netility would search all the available NetAgent from Lan automatically or the user could search manually by click on Search NetAgent 21 Chapter 5 UPS Web management by NetAgent Section1 Introduction After finishing Net
23. digits j eeeeeeeseee System will reboot when these items have been Applied Fig 31 NetAgent 9 Wireless 39 Click on information System Status under Wireless Status it displays the IP address of the wireless network NetAgent Il Information information gt System Status System Status 2 SO loltms Wireless Status MAC Address 00 12 0E 96 3F 7E IP Address Subnet Mask __Meter Char Gateway 192 168 0 1 Bef connguration E Log ntormaton Olr Fig 32 NetAgent 9 Wireles 2 2 5 SNMP This page is to set NetAgent SNMP settings so it can be used by a NMS Network Management System Eg SNMPView SNMPView can be found on the NetAgent Utility CD MIB System System Name This section is to give a name to a NetAgent System Contact This section is to give a name to the administrator System Location This section is to set NetAgent location Access Control Manager IP Address This section is to set the IP address that the administrator can manage NetAgent from It is valid for up to 8 IP addresses To manage NetAgent from any IP address enter into Manager IP address Version This is to select between SNMPv1 amp SNMPv2 or SNMPv3 SNMPv3 only applies to NetAgent 9 series Community This section is to set a Community name for NMS The community name has to be as the same as the setting in NMS Permission This section is to set authorities of administra
24. trap information to the system manager to take proper action 2 2 NetAgent Provides Shutdown Utilities When a computer on the network with the NetAgent utility installed it could locate all the NetAgent on the network When the UPS of this NetAgent is in AC failure condition or Battery Low condition the operating system could close all the files on the system and perform a gracefully shutdown This could avoid system corrupt when a power disconnection happened 2 3 NetAgent Il for Surrounding Monitoring 3Port NetAgent ll could be use to connect the surrounding monitoring utility NetFeeler to get the temperature humidity smoke fire signals These informations could also be revealed on the NetAgent Web page When there is an abnormal condition happened it could also be sent as a trap to the system manager 2 4 When we need the NetAgent When we need to remote monitoring and controls the UPS conditions For example the system manager could use the Internet to control all the UPS conditions all over the country When the shutdown utility is installed the shutdown utility could close all the files and shutdown the system when a power abnormal condition happened O When we need to monitor surrounding conditions of the machine room warehouse office etc For example the system manager could know the temperature humidity smoke and water condition by using the NetAgent Il 3Ports version and NetFeeler Il The system manager c
25. 158 0 157 ni E T MT PARE 2571012800 E LL 75 00 32 58 0 17 4 ABOUT Hetility 391061 55 00 02 EA 02 54 55 182 168 D 161 Basle Varin HAHET Fimea Varann z 4 S52 MAC Address 0 05 ER 0 74 14 5 Refresh List Fig 7 Netility Main Window Launch Device Click Launch Device or double click the NetAgent listed in the table to launch it Enter the Account Login Name and Password Login Password set earlier to login If you did not configure one then just click Apply to login O Network Settings Choose the NetAgent from the right of the screen then click Configure would shows the following setting page IP Address Set IP address for Netagent UPS When use at the first time please set IP address subnet mask and gateway After setting enter IP address from Telnet or Browser to connect to NetAgent s website Configure IP Address Advanced Password Address Configuration C Use folowing static IP address IF Address IP Address 192 168 0 152 Subnet Mask 255 255 355 0 Gateway 192 168 0 4 Fig 8 Netility Configure When using DHCP or BOOTTP to set up IP address IP address Subnet Mask and Gateway would receive directly by the system Fig 8 Netility Set IP address for NetAgent UPS Advanced Advanced Netagent UPS Setting In order to ensure the secure management of UPS Netility provides two protecting function Management Protocol Netagent UPS provides HTTP HTTPS WEB an
26. 2 168 0 41 3927000016 00 03 EA4 11 43 D0 HCV91 3 3 CV91 9722 192 158 0 31 3927000114 00 03 EA 11 44 32 HCV91 3 3 CV91 8222 192 158 0 30 3927000751 DD 03 EA 11 45 AF HCV91 3 3 CV91 9722 192 168 0 162 3927061592 00 03 EA 12 34 58 HCV91 3 4 CV9b 9b20 192 158 0 181 Fig 55 Browse NetAgent Refresh This will re search all the NetAgent in the network 2 42 Serial Port Debug This function is to know the immediate communication between NetAgent and UPS via serial port Port Information This is to configure the communication parameter between NetAgent and UPS Parameters are Debug Mode Port Speed Baud Data Bits Parity and Stop Bits Two encoding formats ASCII or Hexadecimal If Debug mode is set as manually user may enter its parameter under Send Contents column Sent Information This column shows the real time sent command Received Information This display the response that NetAgent receives from UPS 63 Serial Ports Debug Debug Mode Auto Port UPS vj Speed baud 9600 v Data Bits By Parity None v Stop Bits 1 Bit v 9ASCI O Hexadecimal Send Content PO Gend Sent Information IPM 05 13 50 hr PM 05 13 52 Fir P PM 05 13 57 QtTir PM 05 14 02 hr PM 05 14 06 Fir PM 05 14 13 hr PM 05 14 18 Fir PM 05 14 22 Qr PM 05 14 24 hr PM 05 14 28 Fir PM 05 14 33 Qr PM 05 14 38 hr PM 05 14 42 Fir v Received Information TIITII TIITII TIITII o
27. 22 Small Icons Small icon view to display NetAgent UPS s IP address Name location etc lt j SNMPView Enl 2 Device View Tools System User Help Enumerate AddUPS Delete U Group eire Mamta View Event Log Data Lo ves___ Host Name Startup Time D H M 623 192 168 1143 993 132 158 1 142 User Admin Location Fiat 0 UPS LIPS group has been selected 3 LIPS im the list UPS lost communi 85 5 2 3 Details Detailed Information displays NetAgent UPS s IP address name input voltage output voltage battery capacity load frequency etc EELEE Pe ES Device View Tools System User Help P iL Enumerate AddllPS5 Delete U Group Event Log Data Lo ia e R SETTE Mantar Wey E182 158 1 144 UPS My Office AC m Conn 35 0 100 0 2084 1002 ACH 823 192 158 1 143 am 132 158 1 142 IE k User Admin Location Aoot 0 UPS LIPS group has been selected 3 LIPS in the list 2 UPS lost communi lt 524 Map Background Import a map image JPG by right click on the main screen and move NetAgent UPS icon to its suitable location EEEIEE Device View Tools System User Help e Dy M e Ss Enumerate AddUPS Delete U Group Settings Mantar YEW 2 EventLog Data Lo DES Tal wan 192168 1 144 Hongkon g 132 158 1 142 132 158 1 143 User Admin Location Root TUPS OUPS group ha
28. Agent installation including hardware installation and IP setting you are now able to go to NetAgent web site to monitor and control UPS by inputting NetAgent IP address in Browser Starting the Web Brower Netscape or Internet Explore O Enter the NetAgent IP Address Which is setting on Netility e g 192 168 0 156 File Edt View Favorites Took Help Q x A seach fers 03 2 3 39 Ades 41492 168 8 156 Y Neth cer Fig 13 Input NetAgent UPS IP address On the first screen enter the current password If no password has been set just press ENTER Connect to 197 168 0 156 User name v Remember my password Fig 14 NetAgent UPS Login dialog Section2 NetAgent UPS Web Interface Enter NetAgent UPS Web page there are 4 main function items in the first Web page 2 1 Information 2 2 Configuration 2 3 Log Information 2 4 Help 22 Enter the main function item the sub menu items will be shown on the left side of the page When using this NetAgent for the first time please enter the Config menu item to set all the configuration items Then the UPS status could be correctly revealed by other pages NetAgent Information Configuration Log Information Help NetAgent Information Configuration Log Information System Status System Information Hardware Version HCP504 UPS Last Self Test 2010 12 08 14 47 45 Firmware Version 2 44 CP504 EAST UPS Next Self
29. Interface or Contact Closure Interface UPS External SNMP Agent or SNMP Internal Card O Microsoft Windows 95 98 NT 2000 XP Me 2003 2008 Vista 7 19 Section3 Install SNMPView o e Put the NetAgent Utility CD into the CD driver And execute the SNMPView program After installation there will be a NetAgent group in the Windows Start group Click NetAgent gt SNMPView gt SNMPView for Windows to start using SNMPView E Internet Explorer FR DemoShield 7 0 n Adobe Photoshop 7 0 1 Microsoft Excel m Microsoft word Skype NetOgent Trend Micro PC cillin ka SNMPYiew For Windows Fi icamview P sNMPView Online Help A SNMPView Readme Wy SNMPView Uninstall 76 Section4 Using SNMPView When use SNMP view at the first time the system will ask for input the user s name and password Please enter the default value as follows to start the SNMPView User Name Admin Password lt blank gt just press lt Enter gt After the SNMPView program start up the main windows will be displayed The left panel will list the available stations by area and the right panel will list the UPS Host Name Startup Time Manager and Location of UPS found in each station d SNMPView Seles Device View Tools System User Help 9 Lu 6 2 9 BD O Enumerate Add UPS Delete Li Group View Event Log Data Log snails Output Status Connection St Output Voltage 192 168 0185 UPS Agent My O
30. Phone number SMS content Max length 70 characters bL l EN 1j Unicode Character select PPP dial in in Modem communication will restart the system Fig 39 Modem Modem Port Modem Settings el Modem Settings Modem Communication Type NetSwitch J System will reboot when this item has been Applied NetSwitch Setting eee 1 Select NetSwitch MJ Address Change v Identification Outlet Name Phone Controllable Control Type Power Off Delay Power Resume Delay A NO w nstant sh utdowwn Y o sec sec B NO w instant shutdown vi sec 0 sec C NO instant shutdown sec sec D NO instant shutdown b sec a sec E NO instant shutdown J sec 0 sec F NO w instant shutdown b sec 0 sec G J NO instant shutdown oS sec sec H NO instant shutdown b sec sec Fig 40 Modem Port with NetSwitch NetSwitch Status When BT connects with NetAgent this will appears under Information option This section allows remote control over the RPM unit and its individual devices Click on the individual power input icon to either switch on off the device NetSwitch Status NetSwitch Status and Control Select NetSwitch Identification non internet or W non internet uii Al non internet ork non internet
31. Public Key Length 512 bits SSL Certificate Information SSL Certificate aS Upload and Replace Issued To NetAgent Issued By NetAgent Walid From 2010 04 09 Walid Until 2011 04 09 This upload function could not be used in HTTPS mode Fig 43 WEB Telnet E nformation Configuration IHE TI ud SSL Information Bz 8E EET T4 TU Tear E Configuration gt Web Telnet SSL Public Key Public Key Length 512 bits SSL Certificate Issued To NetAgent Issued By NetAgent Valid From 2010 04 09 Valid Until 2011 04 09 Language E ieo mormaer ET T NNI Fig 44 NetAgent 9 SSL Sess NetAgent IX ll g information Configuration gt Web Telnet Configuration Tee CEE RADIUS Server Settings UPS Configuration Enable RADIUS in Web Telnet login NO UPS On Off Schedule RADIUS Server Address Network O lt Authentication Port 1812 Shared Key Connection TimeOut 5 second s Connection Retry cD CD D Web System Time KD Heo Fig 45 NetAgent 9 Radius 2 2 10 System Time This page is to set NetAgent system time You can provide NetAgent with up to 2 time servers or you can set a time zone System Time Time Between Automatic Updates This section is to set an interval for time synchronization 52 Time Server Choose the nearest Time Server to your NetAgent loc
32. S v DES public NoAccess w MDS DES v E 63 3 E public No Access MDS DES v E Lo rrormason C cD c co Fig 35 NetAgent 9 SNMP 2 2 6 Email This page is to set Email details for use by NetAgent NetAgent CP DP series only support SMTP NetAgent BT CT DT series and NetAgent 9 series of BX CX DX supports SMTP and SSL SMTP Email Setting Email Server This section is to set NetAgent Email Server Note that free email server such as Hotmail yahoo Gmail is not allowed Email Port This is to configure the SMTP port to send email Sender s Email Address This section is to set NetAgent s Email address Email Server Requires Authentication This section is to set whether the Email Server requires authentication Account Name This section is to set an Email account name when the email server requires authentication Password This section is to set a password when the email server requires authentication Sending test mail This is to send a test mail by clicking on Test Mail to the mail address configured Recipient s Email Address for Event Log This section is to set Email Addresses to receive warning email sent by NetAgent when an event occurs It is valid for up to 8 Email addresses Send Email When Event Occurs This section is to set NetAgent to send warning Email when an even
33. T ceiui Cellular Phone number merenn EN characters z Log Information Select PPP dial in in Modem communication will restart the system NetAgent Modem Status Information Modem Information Modem Manufacturer SIEMENS Modem Model TC35i Modem Firmware Version REVISION 02 07 2 Serice Provider TW Mobile Configuration Central number of SMS service 886935074443 E Signal Strength 48 SIM card PIN is correct or not SIM card PIN correct or no PIN configured Log Information 103 BP506 SMSConfiguration BP506 Configuration 1 SMS NetAgent 2 Select Local Modem 3 Enter BP506 s username and password leave none leave blank 4 Enter Mobile number 5 Select events to send 6 Click on Apply Information Configuration All Log Information Send SMS When Event Occurs Use Local Modem 2 RET m TEE Catine M 5 etting SMS Server bewo Y SMS Server Port Account Name C fus Cellular Phone number 4 A4 091003360 5 Cellular Phone number 2 tc Cellular Phone number 3 o ts tsisdz 1 Cellular Phone number 4 E Cellular Phone number 5 D O Cellular Phone number 6 O Cellular Phone number 7 1 Cellular Phone number 8 ti E i i 104 Appendix C SMS Server with SMS Modme GPRS MODEM Installation 1 Insert Sim card ER a ABA 2 3 3 NOTE Please make sure there is no co
34. Test Serial Number 3926064075 UPS Critical Load 80 96 System Name UPS Agent UPS Critical Temperature 70 0 C System Contact Administrator UPS Critical Capacity 10 Location My Office System Time 2010 12 09 16 35 44 Uptime 07 13 31 Warning will be initiated 10 minute s before Scheduled Shutdown Event Send Email for Daily Report No Network Status MAC Address 00 03 EA4 02 FB CB Primary DNS Server 168 95 1 1 Connection Type 100Mbps Full Duplex Secondary DNS Server 158 95 192 1 IP Address 192 168 0 185 Time Server time nist gov Subnet Mask 255 255 255 0 PPPoE IP Gateway 192 168 0 1 Email Server Fig 15 NetAgent UPS single port System Status System Information Hardware Version HBT506 UPS Last Self Test Firmware Version 2 44 BT506 UPS Next Self Test Serial Number 3926048866 UPS Critical Load System Name UPS Agent UPS Critical Temperature System Contact Administrator UPS Critical Capacity Location My Office System Time 2010 12 09 16 42 57 Uptime 00 05 32 Warning will be initiated 10 minute s before Scheduled Shutdown Event Send Email for Daily Report No Network Status MAC Address D0 03 EA 02 CO 62 Primary DNS Server Connection Type 100Mbps Full Duplex Secondary DNS Server IP Address 192 168 0 150 Time Server Subnet Mask 255 255 255 0 PPPoE IP Gateway 192 168 0 1 Email Server Fig 16 NetAgent UPS 3 ports 23 80 70 0 C 10 96 168 95 1 1 158 95 192 1 time nist gov B as NetAgent IX
35. User Name User1 Password s Fig 60 Telnet Input User Name Password 66 O Main screen is as follows S Proper Select gt F FEDT eter 1021680144 inn Mat mm Fig 61 NetAgent Telnet window 1 Set IP Address This function allows you to setup IP Address Gateway Address Subnet Mask parameters 2 Set SNMP MIB System This function allows you to set the MIB system group parameters 3 Set SNMP Access Control This function allows you to set the Manager IP Community Access Permission Note The configuration of Set SNMP Access Control is only used for SNMP Network Manager 4 Set SNMP Trap Notification If you want to use a PC and perform the Trap function of SNMP manager to manage UPS through Net Agent the IP address of the PC must be added in this list of Net Agent Note The configuration of Set SNMP Trap Receiver is only used for SNMP Network Manager 5 Set UPS Properties This allows you to setup the Communication Type of UPS UPS Device Name and Battery Replacement Date 6 Set UPS Devices Connected This allows you to setup the System Name Rating which connected Connected 7 Set System Time amp Time Server This allows you to setup the System date time and two time servers 8 Set Web and Telnet User Account This is allows to set users account s authority 9 Set E mail This is allows to set e mail accounts to receive power event notification for emergency management a Reset Configur
36. ailed The TimeServer connection failed The TimeServer connection failed The Timeserver connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The Timeserver connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The Timeserver connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The Timeserver connection failed The TimeServer connection failed The TimeServer connection failed The TimeServer connection failed The Timeserver connection failed The TimeServer connection failed Fig 51 Event Log 58 2 3 2 SMS This page is a SMS Event log It shows a record of all mobile number giving the Date Time of the SMS sent and a detailed description of each When reach to the limit it rewrites on the previous logs Date Time Mobile Number SMS Content 2008 04 21 17 20 250 JZ 1L test 2008 04 21 15 51 4308 JC 386 test cdma Send SMS Failed 2008 04 21 1509 1109 538 lt 192 166 3 22 gt Envir
37. all Model number and Serial number Description of failure or problem Date of failure or problem Customer contact information and return address Orion Power Systems Inc 3811 University Blvd W 3 Jacksonville FL 32217 Web www orionpowersystems com 192321372001004
38. ation The Administrator can choose from the list of a maximum of 30 Time Servers If to add new time server click on Edit and delete any time server from the list provided and add a new one Time Zone Relative to GMT This section is to set a different time zone for different countries Using Daylight Saving Time Choose between Yes or No System Time yyyy mm dd hh mm ss This section is to set NetAgent system time manually oet this in the format yyyy mm dd hh mm ss Auto Restart Auto Restart System for Every n Minute s Use this setting to auto restart the system at a predetermined interval The default value is set to 0 disabled Enter between 1 to 9999 Minute i e between 1 minute or 166 65 hour or 1 to 9999 Hour 1 hour to 416 6 days Manual Restart System After 30 Seconds Use this feature to manually restart the system NetAgent restart in about 30 seconds Backup Time This is to save the event log and data log automatically with the configured hour on external USB flash This only applies on BX NetAgent models and the USB flash disk must be with FAT FAT32 format Time Between Log Backup To configure the time in hour to save log file 53 em Time Time Between Automatic Updates 12 Hours Time Server time nist gov v Exit Time Zone Relative to GMT GMT v Using Daylight Saving Time NO Adjust Now gt gt System Time yyyy mm dd hh mm ss 2009 1 2 29 08 51 54 Auto Restart
39. ation to Default oet all values to their default settings b Save amp Reboot oave the current configuration data including any changes you have made and reboot the Net Agent 0 Exit Without Saving Exit all configuration changes will be lost 67 Section3 Telnet Configuration Use Putty software to configure SSH Telnet encryption on NetAgent 9 This only apply to NetAgent 9 models of CX DX and BX Refer to page 19 to enavle SSH port of 22 Following is the configuration of SSH Telnet Enter the IP address of NetAgent 9 and click on Enter XN PuTTY Configuration x Category Session Basic options for your PuTTY session Logging Specify the destination you want to connect to Terminal Keyboard Host Name or IP address Port Bell 192 168 0 161 22 Features Connection type Window OBa OTelnet ORiogin SSH Serial Appearance Behaviour Translation Selection Colours Connection Data Save Proxy Telnet Delete Load save or delete a stored session Saved Sessions Default Settings Load Rloain SSH Serial Close window on exit O Always Never Only on clean exit m A 192 168 0 161 PuTTY Seles login as aaaalis2 158 0 151 s password Main Menu A 192 168 0 161 PaTTY Main Menu IF Address SNMP MIB System OMMF Access Control MMF Trap Hotificarion UPS Froperties UPS Devices Connected Co Di pL res in mT a Syst
40. click the list to Refresh Event Log 7 Battery Voltage Normal E Communication ARE AC Power Normal i has been made e A f est Mormal d FT n i attery Normal mode Control E UPS UPS Agent i fm x Meter Digital Details Event Log Control e urn Off UPS To shutdown UPS e Reboot UPS UPS shuts down in 12 seconds and reboot in 1 minute e LED Enable LED flashes UPS must supports it e Cancel Shutdown To cancel UPS shutdown UPS must supports it e Simulate AC Fail Simulate AC failed to UPS e UPS Sleep UPS enter sleep mode e Economize UPS Battery Turn off UPS load to save UPS battery capacity UPS Contral Tum Off UPS Turn Off Parameters Reboot UPS m Tum DOff Delay 120 Sec Sleep Time 2 Min Reboot Load Simulate AC Fa UPS Sleep O fonsenwe Bate Execute gt gt C Wake UPS UP Test Control Test Period Self test C Cancel Self test Test every 1 ay Tiesttme Me a BOE ed hn Disable r Battery Voltage Marmal Self test untill battery low Test battery E Lommunication wal C Power Normal E has been made oi P attery Mormal A fi mode 91 Once choose the function that to perform and click on Execute Note UPS must supports those function to perform it Test Control e UPS Self Test Execute UPS Self Test e UPS Calibration Test Execute UPS Calibration Test Turn
41. click on the Delete icon from main function list Hold On Shift to select multi NetAgent UPS Device View Tools System User Help 9 7 2 ESSI IRSS Enumerate AddUPS Delete U Group Settings Mianta View Event Log DataLoa Temperature Loading fa 138231581 UPS Agent hy Office AL made Lonnection 35 0 100 0 is 192168 1 Unknown Network Disc 0 0 0 0 aR 192 168 1 Link cian Mehwunrl Prisc O 0 0 Warming AN Delete all the UPS devices and UPS Group 4 User Admin Location A oot 1 LPS D LIPS group has been selected 3 UPS in the list 2 UPS lost communi lt 5 1 5 Browse Device Highlight the unit to be browsed and click it to enter NetAgent s webpage 5 1 6 Export Configuration This is to save the NetAgent UPS s configuration FHETZLTT ioj x Device View Tools System User Help OG 7 oz Bog e 69 Enumerate 44 DC Malakali Fe Gea mm ler Ex d nn Eo Log Data Lo UPS Save As ki x 3 192 168 1 Save in E SNMPView EN is 192169 1 231921691 LJ Mapbmp aa SNMPLISER dat L msgwaven SOUNDCg DAT 5nmpbD Log dat 5nmpELag dat SMMPFRAME DAT e SnmpU FS Tree dat save as type Test Documents dat L ancel Z 4 k User Admin Location A oot 1 LIPS 0 LPS group has been selected 3 UPS in the list 2 UPS last communi 81 5 1 7 Import Configuration This is to import the configuration of NetAgent UPS that sav
42. configuration RES Reset to factory default Firmware Update Settings FTP Server ftp icv99 com User netagent Password mo Update Now gt gt Apply Auta Update Every 1Day Mla 02 00 Hour Minute Apply Mega System Technologies Inc Tel 886 2 87922060 Fax 886 2 67922066 E mail netagent megatec com tw Firmware Update http Awww megatec com tw gt Fig 57 About 65 Chapter 6 Telnet Remote Configuration Section1 Introduction NetAgent supports multiple Network Management systems and LAN protocols After finishing hardware installation you are now able to choose any utilities that provided by NetAgent to monitor and control UPS Here are introduction for using Telnet Section2 Telnet Configuration Select Start from Windows click Run to key in NetAgent IP Address k E Type the name of a program tolder document ar Internet F resource and Windows will open it For you Oper telnet 192 168 0 144 Cancel Browse A T diosa Fig 58 Telnet startup di Start Successful link up display L lt lt lt lt lt UPS SNMP Agent II Setup Program Version 1 888 gt gt gt gt gt Mega System Technologies Inc Copyright c 2888 All Rights Reserved Fig 59 Telnet Connection Olnitial to setup please press Enter to enter telnet main screen If the User Name and Password had been set before please enter actual value to access T
43. count admin Neglect password ftp admin 192 168 50 179 ftp 192 168 50 179 when using this method to enter the follow error message will be show At this moment select Enter Identity at the top left corner of file menu Then enter admin as account name and password to re enter again FJ ftp 192 168 50 179 Microsoft Internet Explorer File Edit View Go Favorites Help e 4 Back Forward Up Cut Copy Paste Views Address C PRAEAN Undo Delete Properties Go Links 192 168 50 179 Server 192 168 50 179 User Name Anonymous FTP Folder Error Use Copy To Folder on the File m j j m menu to download files and folders An error occurred reading the contents of the folder Make sure the file name is valid and to your computer Click here for d you have permission to access the location specified other useful hints Details The operation timed out 4B Internet Asar 7 S 053 Siep 7 192 168 50 179 Bad sem Once the connection been established the following window will be display Then the user may transfer the latest firmware to here for the replacement in order to complete the updating steps F ftp 192 168 50 179 Microsoft Internet Explorer File Edit View Go Favorites Help Li eo gt fa x amp IwIx E m Back Foward Up Cut Copy Paste Undo Delete Properties Views Go Links
44. d Telnet to reference any related parameter setting for the manager Concerning with security the manager could build use openly or any advance port setting methods Followings are the description 1 At advanced setting two functions were set as activated by using port number 80 and 23 for Http and Telnet As for Https and SSH are 443 and 22 2 Untick means not using the function 19 3 When set to the other port value full IP Address must be entered in order to login to the website or Telnet For example Set 81 as HTTP port number then hitp 192 168 0 177 81 must be typed at the web address to proceed to Netagent UPS s website Set 23 as Telnet port number then 192 168 0 177 24 must be typed at Telnet to proceed to the Telnet screen of NetAgent UPS Configure IP Address Advanced Password Management Protocol HTTP port number 1 655347 Iw Enable Telnet Function Telnet port number 1 555347 Fig 9 Netility Advanced Netility Password After password setting here there is no way to give any command to NetAgent by Netility software without users password NB If lose this password Netagent UPS will never be able to complete any upgrade process Configure IP Address Advanced Password Device Password New password Confirm password Fig 10 Netility Advanced setting of Netagent UPS 20 Firmware Upgrade NetAgent offer convenient firmware upgrade function When you
45. e a ITest Namal Digital E UPS UPS Agent Dox Meter Digital Details Event Loa Control Display NetAgent UPS Input Voltage Output voltage Input Frequency information such as input voltage Value 2083 tput voltage t t a LEO EE output voltage temperature win 2 ty SH capacity etc in digital pg cc NES Battery Capacity UFS Loading Temperature Value Min 100 100 0 350C 950F Max 100x 100x 350C 950F E Communication HL C Power Normal at has been made Gi m a Normal AU s made 73 Batter Voltage Marmal Test Normal Detai Is E UPS UPS Agent ol x i Meter Digital Details Event Laq Control Display NetAgent UPS s IP UE s RN address location user IP Address 192 168 1 144 manufacturer and all other Location My Ofiss n detailed information Manager Administrator Manufacturer SS Model Intelligent M1000K Smart UPS Version M O01 203 12 Sate Voltage FLEE V Batten GORGE V E Current FERE A Frequency EEEEE Hz E Communication e has been made peas Normal ey Batten Voltage 23 Normal P HA Test Normal n C Power Normal 57 A i mode 90 Event Log E UPS UPS Agent M x l Meter Digtal Details Event Log Contral This display event happened with date time and its description 0 2008 5 26 13911 Restore the communication with the UPS Double
46. e current username account as well as close the connection of FTP For example The picture below is to upload the latest NetAgent firmware file c work netagent prjs nag 2 32 DK520 bin which is in this computer to the NetAgent UPS with IP address of 192 168 50 179 ci CAWINDO WSS ystem32 ftp exe Connected to 192 168 586 179 226 Service ready for new user User 192 168 586 179 lt none gt gt admin 331 need password Password 236 OK ftp gt ls 266 Port command successful 156 Opening ASCII mode data connection for file list 2 32 DK526 bin 226 Transfer complete ftp 16 bytes received in 6 66Seconds 16606006 66Kbytes sec ftp ftp gt put c workNnetagent prjs nag 2 32 DK526 bin 200 Port command successful 156 Opening data connection for 2 32 DK526 bin 226 file received ok 1646384 bytes sent in 3 28Seconds 317 66Kbytes sec ftp quit same version new type OK 99 3 Use IE browser to update suitable for BK CK DK BP CP DP version This method is to enter the account password and IP address of the NetAgent UPS which the user wish to update under the website column Once entered user may see the current firmware version and then please copy the latest firmware to here to complete the updating process Two method of entering 1 ftp admin password 192 168 50 179 Again the password here is the one been set at Netility if did not set anything before then enter NetAgent s default value as Ac
47. ed _ re ETT EGIT Bd 192168 1 UPS Agent My Office AC mode Connection 350 100 0 Jemo2 1681 82 5 1 8 Open archive Event Log Open up SnmpElog dat SNMPView would show the event log of all NetAgent UPS aswwve Haa e _ meqwayven Srimpe Log dat Open up SnmpElog dat event log would show as below 192 168 171 144 20085726 13 59 11 Restore the communication with the UPS a I I Senn 83 5 1 9 Open archive Data Log Open up SnmpDlog dat SNMPView would show the event log of all NetAgent UPS Open aswve A _ Mapbmp msgwaven S5nmpLiLag dat A ooo S T T T S e o uUa s e ooo d T T S e e e e e O ooo T T T S e y S e e O oo o T S y y e e ooo T T T S S S e e e es ooo o T T T S S o T e oo LL ELLE y e e e o T T T S ELLE S e ooo o o T T S S y e NN ooo es o S e S y e e ooo T T T T e S e e e oo T S e S y e e ooo es T S e e e e oo es e T e S y e 5 1 10 Quit Exit SNMPView 84 5 2 View S This is to choose the presentation format of NetAgent UPS 5 2 1 Large Icons Large icon view to display IP address and its location EFELER np xi Device View Tools System User Help n ES AX 7 ee eg 5 Enumerate Add UPS Delete Ll Group GEHT ha camamtar We Event Log Data Lo Taiwan Hongkong User Admin Location Root io LIPS LU LIPS group has been selected 3 LIPS in the list 2 UPS lost communi 5
48. em Time Web and Teln 3 Account E mail Configuration to Default amp Reboot DJ Ln aU pawing 68 Chapter 7 ClientMate Windows Shutdown Utility ClientMate is a utility for connecting to NetAgent This utility is for the Windows platform When the ClientMate get the power failure signal from the NetAgent The ClientMate will save the files and shutdown the system gracefully When the hardware installation of the NetAgent has been completed you could install the ClientMate on any of the Windows system on the network When the ClientMate detects the AC Fail Battery Low Schedule Shutdown signals from the NetAgent it will save the file and shutdown the system Please check the operation description here below Section Install ClientMate Put the NetAgent Utility CD into the CD driver And execute the ClientMate program O After complete installation there will be a ClientMate group in the Windows Start group as Interne expiorer ze Outlook Express Nur fe ClientMate SNMPView iis Uninstall fey NetAgent Fig 62 ClientMate Group Click ClientMate to initiate the ClientMate and start using the ClientMate Section2 Using ClientMate Please find the ClientMate main window here below press the left icon to enter the configuration dialog On the right of the window is the current status of the UPS ClientMate 2 1 Configuration 2 5 Connecting IP 2 2 Close File 2
49. entMate Configuration 2 2 Closed Files User could review all the files closed during previous shutdown process If the Auto save application files function has been turn on in the Setting dialog the details of the closed application and files could be reviewed here Closed Files Closed Applications Fireworks MEX Mam Window MiSFaimt4 pn Opus pp obese Files Saved As Outlook Express Browser Class Fig 65 ClientMate Closed Files 72 2 3 About Press this button could review the version information of the ClientMate as here bellowed Llienthd ate Version 5 4 Mega System Technologiels nc Copyright C 2010 Fig 66 ClientMate About 2 4 Event log Press this button could review all the network status and UPS status happened Shown as below Event Log m Event List 2009 1230 17 08 40 132 158 0 1 72 Try connecting ta Host 2009 12 30 17 08 40 192 168 0 1 2 Lost connection to LIPS 20091 2 30 1 7 08 40 132 158 0 1 77 Connection to UPS recovered 2009 1230 17 08 40 132 158 0 1 2 Hast connected Save As Print Clear All Fig 67 ClientMate About 2 5 IP address of connection otatus ICON Description Connecting with NetAgent UPS at IP 192 168 0 162 Does not connect to any NetAgent 73 2 6 AC power status otatus ICON Description The connected NetAgent UPS AC power is normal The connected NetAgent UPS AC power is failed 2 7 Battery Status otatu
50. er state Red light Connection state with UPS 13 4 5 NetAgent 9 Mini Outlook NetAgent 9 DX520 NetAgent 9 DX801 Light signal application of NetAgent 9 Mini Status LED Light color Signal definition Condition description Red Connection state with UPS Flash no connection with UPS Light flashes when Netagent transmits Correspondence state command to UPS Light signal application of NetAgent 9 Mini LAN Port LED Light color Condition description Green On Internet correspond speed is 100M Flash Data transmmiting On Internet correspond speed is 10M Yellow Flash Data transmmiting Chapter 2 NetAgent UPS Installation Before using the NetAgent the proper hardware and software configuration is necessary Hardware installation is to connect the NetAgent and UPS and network Software configuration includes the IP address Firmware upgrade Or using the Browser or Telnet for configuration You could also install the shutdown utility ClientMate to protect your Windows operating system And also could use the UPS management software SNMPView to control and management multiple UPS on the network Connect the NetAgent UPS and Network Chapter 3 Setup the NetAgent IP address or update firmware by using Netility Chapter 4 Using the Brower to connect to Using the Telnet to NetAgent by using the IP configure the NetAgent address of it Chapter 5 UPS settings Chapter 6 Using the shutdown The Ne
51. es before system shutdown xii Run Application before shutdown computer Execute the application before system shutdown xiii Turn Off UPS For NetAgent Only Setting if to turn off UPS power after system shutdown Scheduled Shutdown xiv Shutdown Windows To configure if shutdown or Sleep the Windows system xv Notify Scheduled shutdown before xx Min Time before the Schedule Shutdown to make notification xvi Auto save application files Check if to save the application files before system shutdown 71 xvii Run Application before shutdown computer Execute the application before system shutdown Configure General Power Failure Schedule Shutdown System Shutdown C Use Windows ACPI Interface ACPI gt gt f Clienthate shutdown Windows by s Shutdavir When AL failed commence computer i O shutdown sequence in E z Min When Battery Low commence computer shutdown sequence in E z Min Commence computer shutdown when E Es Battery Capacity lower than 10 Additional Actions Auto save application opened files Run application before shutdown computer Tum off LIPS when shutdown Windows For NetAgent only EJ Configure General Power Failure Schedule Shutdown Schedule Shutdown s Shutdown windows by Notify Scheduled Shutdown before Commence system shutdown before Additional Actions Auto save application opened files Run application before shutdown computer Fig 64 Cli
52. eter of the radius server Please refer to the appropriate radius server setting Only for NetAgent BT CT DT series and NetAgent 9 series of BX CX DX models 50 Enable RADIUS in Web Telnet login To select between Yes or No RADIUS Server Address To enter the IP address of the radius server Authentication Port To enter the UDP communication port number Shared Key This is to enter the password to login to radius server Connection Timeout Set the timeout for completion of RADIUS requests Connection Retry Set the number of retries for RADIUS requests SSL Public Key Information This is to upload the SSL public key Only for NetAgent BT CT gt DT series and NetAgent 9 series of BX gt CX DX models SSL Certificate Information This is to upload the SSL certificate When both public key and certificate are uploaded to NetAgent web server the communication will be encrypted by SSL on the Internet by entering with Http on the browser To communicate via Https make sure to enable Https port 443 See page 19 User Name Password Permission IP Filter C d E d 1 1 EL po NNNM E C eoo _ id id Auto LogOf after idle fe 3 minutes 0 Disable Enable RADIUS in WebTelnet login MO RADIUS Serer Address OoOo f Authentication Part haz 1 Connection TimeOut 5B 1 second s Connection Retry Bo SSL Public Key Information SSL Public Key 4 SES Upload and Replace
53. ffice Unknown MetAgentis no 0 0 0 0 192 168 0 156 APA 303TR eF COMPLITE Unknown MetAagent is na E 192 168 0 172 UPS Agent My Office AC made Connection Ma 4 User Admin Location Root 0 UFS 0 LIPS group has been selected 3 UPS in Ehe list LIPS lost communication 17 19 07 Shows that the device is a UPS Shows that the UPS is Battery Low Shows that the UPS is Disconnect Off Line 11 Sections SNMPView Buttons When use SNMPView configuration could be done by all function icons displayed or right click on the mouse to show functions list Followings are the explanation of each function icon 9 yle Enumerate Add UPS Delete LIPS Settings Monitor View e D Event Log Data Log Options Enumerate Search all SNMP hosts that supports Public group and display them on the screen Add UPS Manually add a host into the window Delete UPS Manually delete a host into the window Group Shows the Main group windows Settings If the host is a UPS just click on it to view and modify the UPS s general information Monitor ss If the host is a UPS just click on it to start monitoring UPS View Display in either Large icons small icons or details EventLog Records the UPS date time and description of an event Datalogi Records data of all UPS listed Sets the SNMP Parameter for community Trap port and UPS SNMP port Options 78 Following is the mai
54. he test item then click on Apply to execute it Please refer to the UPS manual for individual UPS Test functions If you are using a Contact Closure UPS you will only be able to use the function Turn off UPS when AC Failed 10 Second Test This to perform 10 seconds UPS self test Deep Battery Test This function is to execute XX minute deep battery test Test Until Battery Low When execute UPS will test Battery until battery low Cancel Test This function is to abort a test when it is executing Turn off UPS when AC failed Reboot UPS Selecting Turn off UPS when AC failed will turn off the UPS You can reboot the UPS by selecting Reboot UPS Put UPS in Sleep mode for minutes Wake up UPS When the UPS is put into Sleep mode it will not provide power The UPS will provide power again after Sleep mode time is complete Wake up UPS When execute such command UPS will be awake from sleep Reboot UPS When execute such command UPS load would start over UPS Buzzer On Off This is to trigger UPS buzzer On If its ON already execute such command will set it OFF Remote Control UPS Testing OO UPS Testing 10 Second Test O Deep Battery Test fo minute s Test Until Battery Low Q Cancel Test Miscellaneous Turn of UPS when AC power Fails Put UPS in Sleep mode fog minute s Wake up UPS Reboot UPS UPS Buzzer On Ot O00009 Fig 21 Remote Control 2 1 5 Meter Chart This page displays temperature capaci
55. his section is to set a period of time after which NetAgent will send a disconnection warning message This warning message will be sent after NetAgent has lost contact with the UPS for the time specified Critical Loading 96 This section is to set the UPS critical loading shown as 96 NetAgent will send a warning message when the UPS is overloaded Critical Temperature C This section is to set the UPS critical internal temperature NetAgent will send warning messages when the UPS overheats 33 Critical Capacity 96 This section is to set the UPS critical battery capacity shown as 9e NetAgent will send warning messages when UPS low battery occurs Hace m HRSS HSn HEARNS UPS Configuration UPS Properties UPS Communication Type Number of Batteries Battery Full Charge Voltage v Battery Exhausted Charge Voltage VJ mI m m Ol 7 7H Date of last battery replacement yy y mm dd UPS Recorded UPS Data Lag l minute 1m m Test UPS every Test UPS on Weekday Monday d Start Time of UPS Test hh mm UPS Test Type 10 5econd Test 10 inte Warning Threshold Value Time aut after lass of connection 3l seconds Critical Load 35 Critical Temperature C 70 0 Critical Capacity Fig 27 UPS Configuration 34 2 2 2 UPS On Off Schedule This page is to schedule On Off time for the UPS and Wake On Lan Weekly Schedule This section is to set the time to turn o
56. i NetAgent Utility CD User Manual 4 2 Pictures of NetAgent9 NetAgent 9 CX BX Series NetAgent9 CX BXSeries NetAgent 9 CX BX Series a NetAgent 9 Mini DX cmm pxo2zo DXe04 11 4 3 NetAgent 9 Package Contents NetAgent Utility CD including Netility Configure NetAgent IP address update firmware ClientMate Windows Linux FreeBSD shutdown utility SNMPView Windows platform multiple NetAgent UPS management software SMS Server SMS Notification UPS MIB MIB file for the Network Management System Time Server Time adjustment utility And NetAgent installation users manual M2501 Cable For external NetAgent II connection to contact closure UPS M2502 or M2505 Cable For external NetAgent II connection to RS 232 UPS O M2506 Cable For connection 3Port NetAgent and Modem 9V DC Adapter For External NetAgent II 5 3V DC Adapter For External NetAgent Mini 4 4 NetAgent 9 Outlook 1 Port NetAgent Internal External One Port Internal NetAgent 9 oe ahh 1 Ee cue E rt a ud tard Dg i QE B f Eri 3Ports NetAgent Internal External To UPS Three Ports Intenal NetAgent 9 Three Ports Extenal NetAgent 9 To USB Port X2 To NetFeeler II Environment Sensor To Lan Solid ON Flashing Solid ON No connection to UPS Flashing Flashing Solid ON Suiting data to flash memory Green light Pow
57. ion trom Network Trap List Double click on the trap that listed and configure Settings 192 168 1 144 General E Mail SMS Notification Trap List UPS Loading TRAP I 1 0 0 0 0 public Information No 2 0 0 0 0 public Information No ue ES 3 0 0 0 0 public Information Mo Trap Receiver 4 0 0 0 0 public Information Mo 5 0 0 0 public Information No Index il b 0 0 0 0 public Information No T 0 0 0 0 public Infarmatian Mo B 0 0 0 0 public Information Ho Receiver IP 0 0 0 0 Community public Severity Information m Enable Trap Disable Cancel Maximum B Trap Receiver in the list Double click the item Far modification Cancel UPS Loading To configure all the other devices and its load that connects with NetAgent 88 ia Settings 192 168 1 144 Device Information 89 5 3 2 UPS Monitor Highlight NetAgent UPS device and configure Or right click on the highlighted device and click on monitor device Meter E UPS UPS Agent Mi Ea Meter Diaital Details Event Loa Control Display NetAgent UPS i Input voltage Output Voltage Capacity UPS Loading information such as input voltage output voltage temperature dus capacity etc in diagram Puce Nes Input Frequency Temperature E Communication ARB AC Power Normal req Batten Voltage v has been made e 23 Normal Battery Mormal AU C mad
58. lar Phone number 1 Doo O Cellular Phone number 2 Doo Cellular Phone number 3 Doo Cellular Phone number 4 Doo Cellular Phone number 5 o 0 0 O Cellular Phone number 6 fe Cellular Phone number 7 fe Cellular Phone number 6 fe Fig 37 SMS 46 Beas NetAgent IX ll g CE E Configuration SMS Setting BUG GTS Say SMS Server SMS Port a Account Name Password Sending test SMS Test SMS SMS Tl rm c wa Log Information Fig 38 NetAgent 9 SMS 2 2 8 Modem For 3 Ports NetAgent Il only This section is to configure Modems setting if 3 ports NetAgent connects with GSM GPRS Modem Modem Setting Modem Communication Interface Communication Type Suitable Condition SMS When NetAgent connects with Megatec s GSM GPRS Modem PPP Dial in When NetAgent connects with dial in modem NetSwitch When NetAgent connects with BT NetAgent SMS Setting SMS Communication Communication Type Suitable Condition GPRS To use with GSM 900 1800 or GPRS 900 1800 1900 frequency and make sure the local telecom supports such service CDMA To use with GSM 800 900 1800 frequency and make sure the local telecom supports such service SIM Card PIN Enter the SIM password Confirm SIM Card PIN SIM Password must match the one set above Receiver cellular number and message content To send instant SMS enter recipient s mobile number and SMS text with configurable of Unicode or Character format
59. lected DDNS provider Login Name This is the Login Account name that you have created with the selected DDNS provider Login Password Enter the Password you have assigned to your DDNS Account Use external STUN server to get Public IP to register Choose Yes to ensure that NetAgent uses the WAN Public IP to update the selected DDNS server PPPoE Use this option to allow NetAgent to connect to the Internet directly using your xDSL modem Once set up NetAgent will connect directly to the Internet without going through a router The LCD will display the current WAN Public IP instead of the LAN IP Address When Connection should be made This is to set if use PPPoE to connect with NetAgent UPS Disabled Default setting Connect always NetAgent will automatically dial up and maintain continuous connection Login Name Enter the login name assigned by your ISP Login Password Enter the password assigned by your ISP Note System will reboot if any configuration applies 3 IP Address subnet Mask Obtain an IP address DNS Server IP Primary DNS Server IP 158 95 1 1 secondary ONS Server IP 158 95 182 1 Ethernet stop UPS communcation when Ethernet disconnected Sevices Provider None v Domain Name Login Name Login Password Use external STUN server to get Public IP to register Primary STUN Server IP 211 21 67 53 Secondary STUN Server IP PPPoE
60. m 1 Click on SMS in the NetAgent Webpage 2 Enter the SMS server s IP Service Port NetAgent amp SMS Server port that use for local connection Service account Account authentication for sending SMS Leave blank if no such setting Service password Password authentication for sending SMS Leave blank if no such setting To send SMS when event occurs YES OR NO 3 Enter mobile number to receive event by SMS 4 Select the event that needs to be send 5 Click Apply 2 UPS Agent My Office Microsoft Internet Explorer EIB BRE RED WAO BAREA IA BAH ae 6 E pe yr ROBE e 2 828 Ly B20 Emmmmiwowy RG NetAgent SMS Information Configuration SMSen send SMS When Event Occurs eS Server 952 168 0 1 SMS Server Part B Account Name Password sending test SMS Test SMS Receiver cellular number for Event Log 3 A Log Information ellular Phone number 1 ellular Phone number 2 Select Help ellular Phone number 3 Select ellular Phone number 4 Select ellular Phone number 5 Select ellular Phone number 5 Select ellular Phone number 7 Select ellular Phone number sd Select Seas O 107 Orion Power Systems Service and Technical Support If you have any problems or questions with the UPS or communications call your local distributor or Orion Power Systems technical support at the following telephone number In the United States 1 877 385 1654 Please have the following information ready when you c
61. n function icons and its reference chapter Sub List 5 1 1 Enumerate 5 1 2 Add Group 5 1 3 Add UPS 1 4 Delete 5 1 Device D 5 1 8 Open archive Event Log 5 1 9 Open archive Data Log 5 1 10 Quit 5 2 1 Large Icons 5 2 View S 5 2 2 Small Icons 5 2 3 Details 5 2 4 Map Background 5 3 1 UPS Settings 5 3 Tools P 5 3 2 UPS Monitor 5 3 3 SNMP Management 5 4 1 Event Log 5 4 System S 5 4 2 Data Log 5 4 3 SNMP Option e 5 5 1 Change Password MISERUM e 5 5 2 Account Management 5 6 1 Hel EPA 5 6 2 A 19 5 1 ENUMERATE D Start SNMPView and press the Enumerate button SNMPView will start a search for all the Seen NetAgent on network pimus mn mnnn seo vom and list them in the main window 5 1 1 Enumerate When press SNMPView will start a search for all the NetAgent on network and list them in the main window 5 1 2 Add Group This is to edit or display all REIS IAs the group station of NetAgent under network LIPS Group Group name Enable Background Map Emwee 511 3 ADD UPS Click Add UPS to enter x the IP address of the UPS manually Once entered the UPS will be shown on the main list UPS Information IP address Community public This UPS is a 3 Phase UPS Add subsequent f devices cane 80 5 1 4 DELETE UPS Highlight the unit to be deleted from main list and right click on it to choose Delete or use
62. n off the UPS each day in the week Date Schedule This section is to set the time to turn on off the UPS on particular days Eg holidays The settings here override the settings in Weekly Schedule Warning will be initiated before Schedule shutdown event NetAgent will send a warning message before a scheduled shutdown This section sets the delay time period after the message is sent and before the scheduled shutdown is started Wake On LAN This section is to wake the PC within the network Make sure the PC has such function supported and configure as Enabled under BIOS Enter the IP address of that PC and system would search its IP accordingly UPS On Off Schedule Sunday Monday Tuesday Wednesday Thursday Friday Saturday Turn On hh mm Turn Off hh mm eekly Schedule Date Schedule Turn On hh mm Warning will be initiated 10 minutes v before Scheduled Shutdown Event ake On Lan Host PL MAC Host2 P 1 MAC Host3 PL MAC Host P MAC Hostb PL MAC Host MAC Host Pi MAC HostB IP MAC Fig 28 UPS On Off Schedule Turn Off hh mm say Al a4 m m m on on en Ho m en say ay a4 m m m on on m Ho m en 2 2 3 Network This page is to set NetAgent Network settings IP Address IP Address This section is to set NetAgent IP address Subnet Mask This section is
63. nel will list the UPS Host Name Startup Time E Settings Manager and Location of UPS found in each station Monitor Shows that the device is a UPS E HIM Help Z View Event Log Data Log Option Menu d f that the UPS is Battery Low Shows that the UPS is Disconnect 5 6 2 About i Display the current SNMPView version PAUE Copyright E information and vea 4 6 0 11 Copyright C 2001 2003 Megalec System Technologies product service Inc contact License 2 Test EN sF megatec For more information please send email to zserviceceimegatec com Ebw for product service on SNMP Yew 97 Appendix A Update the firmware of NetAgent UPS NetAgent provides the following convenient methods for user to update the latest firmware of the NetAgent 1 Click firmware upgrade under About of NetAgent webpage and it would link to Megatec s server to download the latest firmware Then use Download Firmware from Netility to upgrade it Mega System Technologies Microsoft Internet Explorer BRO SEO WAC KORE IAD KID Q O HAO se js 2 28 10 SED httpz Neww megatec com tw Downlosd htm gez 98 2 Use FTP to update suitable for BK CK DK BP CP DP using firmware version 2 35 and later The FTP is a easy and common way to upload the latest firmware into the NetAgent Please follow the instruction below to update the firmware If there is other FTP client applica
64. nflict port with the GPRS modem SMS SERVER Software Installation Click on exe for installation 1 tw SMS Server File Edit View Favorites Tools Help ec HRS n e a a Search lis Folders Ei Address C Program Files MetAgentisMs Server te File and Folder Tasks DACL SME Server Mega system Technologies Inc ri Rename Ehis File By Move this File 4 5msAgentqui um ipe Unistall Sem LM SMS Server Inr diy B Copy this File Mega System Technologies Inc agi Icon ES Publish this File to the Web E mail Ehis File x Delete this File Other Places cy MetAgent GB My Documents p Shared Documents E My Computer a My Network Places 105 2 Once installed the icon would appear on the tool bar Shi Server TOR Modem Information GSM Modem Status Modem Type GPRS Modem Connection Connected Service Provider Tw Mobile Signal Quality Bl PIN authentication Password is confirmed SM5 central number Bab33507 4443 r Modern Information Modem SIEMENS Modem Type MESS Modern firmware REVISION 04 00 2 SMS Server Software Configuration Settings Network Service part ati Mas connection 50 ud Server Require authentication ACGOUAL SMS Com port com Modem Type GPRS Retry times 1 SIM FIN Confirm SIM PIN ES Check peer country code County code Da General Event items at a page 106 3 NetAgent sends SMS via mode
65. nmental humidity which detected by NetFeeler II 60 2007 08 17 17 21 26 114 0 113 0 53 9 i 100 320C 89 6F 2007 09 17 17 20 25 114 0 114 0 59 6 100 32 0C 88 6F 2007 09 17 17 19 25 113 0 114 0 53 8 i 100 32 0C 88 BF 2007 09 17 17 18 24 114 0 115 0 59 9 i 100 32 0C 89 BF 2007 08 17 17 17 24 114 0 114 0 59 9 ij 100 32 00 89 6F 2007 09 17 17 16 23 115 0 114 0 59 9 i 100 32 0C 89 6F 2007 09 17 17 15 23 113 0 114 0 59 3 i 100 32 00 88 BF 2007 09 17 17 14 22 114 0 114 0 59 9 i 100 3200 89 6F 2007 09 17 17 13 22 114 0 1130 59 6 i 100 320C 69_6F 2007 09 17 17 12 21 114 0 114 0 599 0 100 32 0C 69_6F 2007 03 17 17 11 21 114 0 113 0 53 3 i 100 32 0C 89_6F 2007 09 17 17 10 20 114 0 115 0 598 100 32 0C 89 BF 2007 08 17 17 03 20 114 0 114 0 59 9 i 100 32 0C 89 6F 2007 03 17 17 08 13 114 0 115 0 5g 9 100 32 0C 383 5F 2007 09 17 16 48 10 113 0 112 0 59 8 0 100 32 0C 89 6F 2007 09 17 16 47 08 113 0 112 0 59 9 0 100 32 0C 88 BF 2007 08 17 16 46 09 113 0 113 0 59 9 i 100 32 0C 89 6F 2007 08 17 16 45 08 113 0 113 0 53 9 i 100 32 0C 83 6F 2007 08 17 16 44 08 113 0 113 0 50 i 100 32 0C 69_6F 2007 09 17 16 43 07 113 0 113 0 5988 ij 100 320C 89 6F 2007 09 17 16 42 07 113 0 112 0 59 9 i 100 32 0C 69_6F 2007 09 17 16 41 06 113 0 113 0 59 8 0 100 32 0C 83 6F 2007 08 17 16 40 06 113 0 112 0 53 9 100 32 0C 89 BF 2007 08 17 16 33 05 113 0 114 0 59 9 100 32 0C 88 BF 2007 09 17 16 38 05 112 0 112 0 59 9 0 100 320C 89 6F 2007 09 17 16 37 04 112 0 112
66. notification NetFeeler Il Status Environmental Temperature This section is to show current temperature which is detected by NetFeeler Il Environment Humidity This section is to show current humidity which is detected by NetFeeler II shown as Water Status This section is to show water presence ie flood which is detected by NetFeeler Il Gas Status This section is to show gas presence which detected by gas sensor When leakage of gas detected sensor would beep and stops only when gas vanish Smoke Status This section is to show smoke presence ie fire which is detected by smoke sensors Security Status Security1 Security This section is to show open close status for doors and windows One NetFeeler ll could monitor up to 7 Security Sensors Refresh status every 10 seconds NetFeeler Lite Status Environmental Temperature JU DC B4 2F Environmental Humidity 13 96 Water 5tatus Normal Gas Status Normal Smoke Status Normal Security Status Normal Security Status Normal Security3 Status Normal Security4 Status Normal Security5 Status Normal Security6 Status Normal Security Status Normal Fig 26 Environment Sensors NetFeeler II 31 2 2 Configuration Sub Menu 2 2 1 UPS Configuration 2 2 2 UPS On Off Schedule 2 2 3 Network 2 2 4 SNMP 2 2 5 Email 2 2 6 SMS 2 2 Modem Port 2 2 8 NetFeeler Il 2 2 9 NetSwitch Action Apply on BT Model 2 2 10 WEB Telnet 2 2 11 System Time 2 2 12 Language Please
67. nt status Users can choose an interval from the drop down box to refresh the status readings UPS Status This section is to show the UPS power status The abnormal status will be displayed in red when there is a power event Input Status This section is to show the UPS input status including AC Status Input Voltage Input Frequency Values here will be shown in red when an abnormal status condition occurs Output Status This section is to show the UPS output status including Output Voltage Output Status UPS Loading Values here will be shown in red when an abnormal status condition Occurs Battery Status This section is to show the UPS Battery Status including Temperature Battery Status Battery Capacity Battery Voltage Time on Battery etc Values here will be shown in red when an abnormal status condition occurs Current Status Refresh status every UPS Status UPS Normal AC Status Mormal Input Line Yoltage 112 0 V Input Max Line Voltage TZ SN Input Min Line Voltage 102 0 W Input Frequency 54 5 Hz Output Voltage 112 0 Dutput Status Line Interactive Standbiyr UPS load 95 Temperature 31 D C 87 8 F Battery Status Battery Normal Battery Capacity 55 Battery voltage 13 7 V Time on Battery 00 00 00 Estimated Battery Remaining Time 00 00 00 UPS Last Self Test UPS Next Self Test Help Fig 20 Current Status 2 1 4 Remote Control This page is to provide remote UPS test functions Choose t
68. ntering the IP address of the PC li Host Press the Query to search the host on the network automatically If a host located on different network segment Please input the IP in the HOST edit box The IP searched on the Connect Query N The NetAgent Host S The UPSilon2000 or RUPS2000 Host 70 iii SNMP Port and Community Name For NetAgent only The community name and SNMP port must be the same as configured on NetAgent Default SNMP Port is 161 iv Broadcast Warning Messages On Server platform only To configure if sending the warning messages when power failed only for WinNT Win2000 and XP server operating system v Configuration Password To set if password is require to be entered when effect any new setting on ClientMate If lost of password just re install the ClientMate Power Failure vi Use Windows ACPI Interface To shutdown the server via Windows ACPI vii Shutdown Windows To configure if shutdown or Sleep the Windows system when power failure viii When AC failed commence computer shutdown sequence in xx Min To configure the time delay between the AC failure and the system shutdown ix When Battery Low commence computer shutdown sequence in xx Min To configure the time delay between the Battery Low and system shutdown x When Bettery capacity reaches to X To configure to shutdown when battery capacity meets at 96 Xi Auto save application files Check if to save the application fil
69. onment Humidity Normal 2008 04 21 15 08 410 0 33871 192 168 3 22 Environment Humidity Overrun 2008 04 21 11 13 39C 1007 3 test sms 01 2008 04 21 17 17 4306 90 38 test 2008 04 21 10 47 4505 00 38 192 168 3 22 Environment Humidity Overrun 2008 04 21 10 47 150 10C 3E 1 192 168 3 22 Emaronment Humidity Normal Fig 52 SMS Log 99 2 3 3 Data Log This page is a UPS data log It records UPS Input Voltage Output Voltage Frequency Loading Capacity Temperature When reach to the limit it rewrites on the previous logs Logs can be saved in CSV format by clicking on Save Data Log Date Time This is a record of the Date yyyy mm dd and Time hh mm ss that the data was recorded The interval between every log can be set in Configuration UPS configuration UPS recorded UPS data Log Input Volt This section shows records of the UPS Input voltage readings Unit Volt Output Volt This section shows records of the UPS Output voltage readings Unit Volt Freq Hz This section shows records of the UPS Input Frequency Unit Hertz Load This section shows records of the UPS Output loading shown as 96 Capacity This section shows records of the UPS battery capacity shown as 9 Temp This section shows records of the UPS internal temperature unit degrees Centigrade Env Temp This section shows environmental temperature which detected by NetFeeler Il Env Humidity This section shows enviro
70. or NetAgent web pages When users first start to open the webpage of NetAgent NetAgent will auto detect the language in the computer system and show the same language on its web pages Users can also choose the languages they prefer from the Interface Language list Note Users will have to enable cookies before they use this function Email Preferences Select language preference when receive emails and SMS English See oep O stz O HAS Deutsch Portugu s O Espa ol O Francais O Italiano O Pyccknit O T rk e O mu Note Setting preferences will not work if you have disabled cookies in your browser Email Preferences Use below interface language in Email and SMS notification English v Fig 49 Language NetAgent CP and DP s model divides the language firmware into two EAST and WEST East Firmware English gt Traditional Chinese Simplified Chinese Korean gt Japanese Russian gt Thai English gt German Portuguese Spanish French Italian gt Turkish gt Russian NetAgent CT DT and BT supports the following languages English Traditional Chinese Simplified Chinese Korean Japanese Russian Thai German Portuguese Spanish French gt Italian gt Turkish Russian gt Polish NetAgent 9 CX DX and BX supports the following languages English Traditional Chinese Simplified Chinese Korean Japanese Russian Thai German Portuguese Spanish gt
71. orts 1 3 phases Internal NetAgent Mini NetAgent Utility CD User Manual Internal NetAgent Mini NetAgent Utility CD User Manual Internal NetAgent Mini NetAgent Utility CD User Manual Enternal NetAgent Mini NetAgent Utility CD User Manual 5 9V DC adapter Enternal NetAgent Mini Dry Contact NetAgent Utility CD User Manual 5 3V DC adapter Jj Internal 1 Port 1 3 phases Internal Internal External External 1 Enternal NetAgent Mini with LCD pP532 Display ili xterna DT532 2 NetAgent Utility CD 3 User Manual 4 5 3V DC adapter DT CT version same dimension as DP CP DT CT has RTC and 2MB flash to maintain correct date time and log saving 3 2 Pictures of NetAgent Il NetAgent II BP CP CT DP CT Series 3 3 NetAgent Package Contents NetAgent Utility CD including Netility Configure NetAgent IP address update firmware ClientMate Windows Linux FreeBSD shutdown utility e SNMPView Windows platform multiple NetAgent UPS management software SMS Server SMS Notification UPS MIB MIB file for the Network Management System Time Server Time adjustment utility And NetAgent installation users manual M2501 Cable For external NetAgent II connection to contact closure UPS M2502 or M2505 Cable For external NetAgent Il connection to RS 232 UPS O M2506 Cable For connection 3Port NetAgent and Modem e 9V DC Adapter For Ex
72. ould always know these surrounding conditions by using a Web browser Browser Telnet NMS SNMPView UPSilon 2000 Option for Unix Ede ClientMate for FreeBS Free ClientMate for Windows Free RS232 OPS Fig 1 NetAgent connection Software Remotely Manage d NM D VT einet NMS di t D gen itus i PD Le Durga 3 port internal Router NetAgent Il 3 port external Serial RS232 Local user Using Browser Telnet NMS SNMPview Mobus PDA WAP PBX system SML LL LIU GPRS Mod sin rowser Iennet r NMPview Mobus PDA WAP Used for Siete SMS Fig 2 3 Port NetAgent II Diagram Section3 NetAgent Models 3 1 NetAgent Models NetAgent II Model DP520 DT520 DP801 DT801 DP802 DT802 DP522 DT522 DP523 DT523 E Package Contents 1Port Internal card NetAgent Utility CD User Manual 1 2 3 1 1Port External card 2 NetAgent Utility CD 3 User Manual 4 Adaptor 1 3 Port External Agent 2 NetAgent Utility CD 3 User Manual 4 M2501 Cable for Contact Closure UPS 5 M2502 or M2505 Cable for RS232 UPS 6 M2506 Cable for Modem 7 9V DC adapter 1 3 Port Internal card 2 NetAgent Utility CD 3 User Manual 3 M2506 Cable for Modem Internal External 1 3 Ports 1 3 phases Internal 1 Port 1 3 phases External External 3 Ports 1 3 phases Internal NetAgent Mini Model Package Contents Internal External 1 3 P
73. s ICON Description The connected NetAgent UPS battery is in normal condition The connected NetAgent UPS is in battery low condition 2 8 Status History On the main menu of ClientMate the Status History showing all the network status and UPS status happened 74 Chapter 8 SNMPView Windows Based UPS Management System Section1 Introduction SNMPView is a software to remotely monitor and control multiple UPS connected to a network When an event occurs SNMPView can be programmed to send an email or a pager to inform the designated network manager It can also inform the user of the UPS current condition or configuration perform self test send a history file turn the UPS On Off and more SNMPView features A windows interface that is simple and user friendly O Automatic detection and identification of any UPS with NetAgent II or NetAgent Mini connected to a network Capable of simultaneously monitoring up to 1 000 UPS O Remotely control monitor and manage the networked UPS Turn On Off Self test etc Able to simultaneously support both RS 232 Interface 1 or 3 phase and Contact Closure Interface UPS Q UPS condition displayed in either a graphic or analog bar chart Supports MegaTec s SNMP Agent and SNMP Internal Card Able to send email for notification O Able to send SMS for notification Section2 System Requirements LAN WAN network system with TCP IP e RS 232
74. s been selected 3 UPS in the list UPS lost communi P 86 5 3 Tools P Highlight NetAgent UPS device and configure 5 3 1 Settings General This to configure UPS information record UPS event enable trap alarm etc Email Send email notification when event occurs sender Display name Please enter sender display name Sender email address Please enter sender email address SMTP server address Enter SMTP address IP address or domain name Server requires authentication Click Setting then enter your Account Name and Account Password Notified Email Address Click add and enter new email address Settings 192 168 0 172 9 9 LIPS Mame Locatior iM v Office Manager Administrator Community public Polling Interval i 0 E Sec default 10 sec i Record Data every 5 ES Min default 5 min Iw Record LIPS Event Enable Warning Message Enable Broadcastng arming Message only For NT 2000 P This UPS iz a 3 Phase UPS SMS Notification Send SMS when event occurs 87 Settings 192 168 1 144 General E Mail SMS Notification Trap List UPS Loading W Enable Device SMS Notification Event phone Mumber AL Failure Jost 2345578 UPS Battery Low H1 2345578 AL Power Restored Recovered fram Low Battery Impending Scheduled Shutdown UPS Failure Lost communication with LIPS Restore communication with UPS Lost communication with Network Restore communicat
75. s below 41 UPS Events Schedule Shutdown Event UPS Failure WPS entering Test mode WPS entering Sleeping mode WPS entering Boost mode WPS Load Overrun WPS Communication Lost Turn Off UPS AUC Power Failed WPS Battery Low WPS Temperature Overrun WPS Capacity Underrun WPS entering Bypass mode NetFeeler Lite smoke Alarm Water Alarm sas Alarm security Alarm Environmental Temperature Overrun Environmental Temperature Underrun Environmental Humidity Overrun 0000 0 Off 00 0000000000F ooooooooHMoooooooooooooH Environmental Humidity Underrun Fig 33 UPS Events Device Connected This section is to set the usage power and connection status of other devices which connects to the same UPS as NetAgent uses SNMP UDP This is to configure the UDP port of the NetAgent and trap receiver SNMP default port is 161 and Trap MIB is UDP162 MIB S tem System Name System Contact System Location
76. set each parameter correctly so that NetAgent would operates properly Note This page s selection would differ according to the differnent interface of the UPS 32 2 2 1 UPS Configuration This page is to set the UPS configuration Any wrong settings will cause incorrect display values or disconnection between the UPS and NetAgent UPS Properties UPS Communication Type This section is to set up the communication interface of the UPS eg Contact Closure Megatec Phoenixtec Megatec 3 phase etc Please refer to the UPS manual to set the correct communication type Any wrong settings will cause disconnection between the UPS and NetAgent Number of Batteries Battery Full Charge Voltage V Battery Exhausted Charge Voltage V Please refer to the UPS manual to set the value Date of last battery replacement yyyy mm dd This section is to record the date when the UPS battery was last replaced UPS Recorded UPS Data Log This section is to set how often the UPS data should be logged Test UPS Test UPS for every This section is to schedule the UPS to test once a week or once every two weeks or not to test Test UPS on Weekday This section is to set the UPS to test on a particular day of a week Start Time of UPS Test hh mm This section is to set the UPS to test at a specific time on the test day UPS Test Type This is to select which test to perform Warning Threshold Value Time out of after lost of connection T
77. t occurs Account 1 8 8 email addresses could be configure with selected event 44 Event This section is to select events for NetAgent to send warning email Clicking on Select will open a Select Events List Event email may be selected from this list The list is the same as under SNMP setting Please refer to page 35 figure 31 Recipient s Email Address for Daily Report This section is to set Email Addresses to receive Daily Report email sent by NetAgent when an event occurs It is valid for up to 4 Email addresses Send Email for Daily Report hh mm This section is to set a particular time for NetAgent to send Daily Report every day Send email when Event Log overflows 500 records oelect YES to have NetAgent send a warning email stating Event Log has reached 500 The data will now be purged to make room for new data Send email when Data Log overflows 500 records Select YES to have NetAgent send a warning email stating Data Log has reached 500 The data will now be purged to make room for new data Email Server o f Email Por Senders Email Address o f Email server Requires Authentication NO Account Name fe Password fe Sending test mail o f send Email When Event Occurs send Email far Daily Report hh mm a 200 send Email when Event Lag overflows 500 records send Email when Data Log overflows 500 records Fig 36 Email 45 2 2 7 SMS When UPS events occurs it allows Short Message Signals
78. tAgent Mini to the serial port of UPS e Plug the DC adapter to UPS outlet the DC plug connected with NetAgent Mini 2 2 For Internal NetAgent Mini Please make sure the connector direction of the cable is correct before connecting to the NetAgent O Connect the NetAgent module to LAN using the UTP port Warning Please make sure the input Voltage and Frequency of the DC power adapter NetAgent Il DC 9V NetAgent Mini DC 6V or 5 3V is correct before plug the power into 17 Chapter 4 Using Netility Setup IP Update Firmware Section1 Install Netility Insert NetAgent Utility CD to the CD ROM driver and execute Netility exe O After complete installation there will be a Netility group in Windows Start gt Program Group m MegaTec Ld rn Metilityy k Fj SMMPView gt Fig 6 Netility Group eClick Netility could initiate the Netility and enter the mail window for configuration Section2 Using Netility The main window of Netility is here below left table is to show you all of NetAgent be searched in LAN right side is function selection menu 1 Launch Web User Interface Laund aN eT ili ty i j Netweoek 2 Network Settings A sang _ Search for device s LAN IP Serial Number MAC Address IP Baldi es F0 3 E 00 74 14 132 168 0 183 354 QO 02 5 A0 HTD D I2 LEO UG Firme 39259651 451 0O D2 E D1 5R Fj 122 L6B 0 052 3 Upgrade Hetf gent Firmware Uparade Dus ee eo 132
79. tAgent management utility ClientMate to utility SNMP View could be used connect to NetAgent UPS to manage multiple NetAgent Chapter 7 Chapter 8 Fig 4 NetAgent UPS installation flowchart 15 Chapter 3 NetAgent UPS and Network Connection NetAgent Il and NetAgent Mini provides External and Internal model for different UPS interface requirement Please reference the following description for detailed information of UPS and network connection Sectionl Install the NetAgent Il with UPS and Network NetAgent II External NetAgent II Internal To LAN Insert NetAgent into UPS slot O To LAN AC Power Fig 5 NetAgent II Installation 1 1 For External NetAgent Il Connect the NetAgent Il Adapter to LAN using the appropriate UTP port Connect the specified serial cable M2501 M2502 M2505 from NetAgent II Adapter to the serial port of UPS Plug supplied AC adapter to the wall socket the other side connection with NetAgent Adapter O UPS with AC 1 2 For Internal NetAgent Il Insert the Net Agent Card into the slot of UPS O Connect the Net Agent Card to LAN using the appropriate UTP port 16 Section2 Install the NetAgent Mini with UPS and Network NetAgent Mini External NetAgent Mini Internal To UPS yero Q9 1o LAN DC Adapter To UPS 2 1 For External NetAgent Mini Connect the NetAgent Mini to LAN using the UTP port O Connect the cable from Ne
80. ternal NetAgent II 5 3V DC Adapter For External NetAgent Mini 3 4 NetAgent Il Outlook 1 Port NetAgent Internal External One Port Internal NetAgent II AD 7 4 A d LJ MES E c AE a UN Memmi ivt i WHITE O y s E HASLLLILITTTITI iip fo Lh nac sm sb LITETEEHETEEEEETO PULL TLL wii m C APIUHLIBO r dio o o gt s So PEOTI SCENEN fz is dd uu a pens t gt cafe 5 3 yi j n dick e M e N T in SERGE 3 EN a ARA HET AM LE A JO MAL t 1 To Lan ae 2 One Port External NetAgent II To UPS Zz ct o ga D 2 et Dd DC Input 3Ports NetAgent Internal External Three Ports Internal NetAgent Il MegaTec dgeai c 0 i 6P CB 013 ver4 1 EMO 8 BE AEn DATE 2007 12 i i l i TT BGT 2 To NetFeeler II Environmental Sensor LE PL BLU To Modem GSMIGPRS nr he E amp mmm To Lan Three Ports External NetAgent II To NetFeelr II Z pa b Environmental To Sensor UPS gt To Modem t GSM GPRS um j To Lan DC Input LED Table Solid Off Solid ON Power ON Solid ON Solid ON System initial olid ON Solid Off Solid ON Normal operation lid ON Flashing Solid ON NO connection to UPS Flashing Solid ON Whiting data to flash memory Green light Power state Red light Connection state with UPS Fig 2 NetAgent II Out looking
81. tion on your computer that will also be fine to use it for updating the firmware For example if wish to update the latest firmware of the NetAgent UPS which IP address is 192 168 50 179 then please operate with the steps below 1 Enter Windows then type ftp 192 168 50 179 under Run of the Start Menu UMEN eee 31 xl Type Ehe name of a program Folder document or j Internet resource and Windows will open it Far vau Cancel Browse 2 After executed the systems will requests for the user name and password Please enter admin under the user name and enter the password that was been set at Netility under password If did not set before then please enter the default value as user name admin and nothing under password press Enter Once the account and password been checked the server will response with 230 OK to indicate Login succeeded f entered wrong account and password the server will response with 530 Not Logged in to indicate Login failed 3 Operation commands as followings 1s This command is to request server to list up all the file and sub file under current Menu User may finds out the firmware version of the NetAgent UPS of its IP put client s file route This command is to ask the client to copy its specific file route to the Server point User may use this method to upload the latest firmware to the remote NetAgent quit This command is to allow the user to logout with th
82. to set NetAgent Subnet Mask Gateway This section is to set NetAgent Gateway Obtain an IP address This section is to choose to set NetAgent IP address manually or via DHCP The above 4 sections can be set in Netility as well NetAgent will reboot after any of the above are changed DNS Server IP Primary DNS Server IP This section is to set NetAgent primary DNS Server IP address Secondary DNS Server IP This section is to set NetAgent secondary DNS Server IP address NetAgent will use the secondary DNS Server IP address when the Primary DNS Server IP address is not working Ethernet Connection Type This section is to set communication speed between NetAgent and Network NetAgent will reboot after Connection Type is changed Stop UPS communication when Ethernet disconnected This section is to set if to stop UPS communication when NetAgent disconnects with Ethernet Dynamic DNS This is a free service that allows the user to alias a dynamic IP address to a static hostname Sevices Provider NetAgent can be configured to register with any of the Dynamic DNS providers In general to register a Domain Name a Go to the DDNS provider website listed b Register a new user account and password with the DDNS provider c Choose a Domain Name to point to your current Dynamic IP d Enter information obtained in b and c into NetAgent DDNS fields 36 Domain Name This is the Domain Name you have created from the above se
83. tors Options are Read Read Write and No Access Username password When select SNMPv3 username password must be entered Password must be at least 8 characters Sender and Recipient s password must match to communicate Authentication This is to select between MD5 and SHA Length must be at least 8 characters Privacy This is to select DES and AES Length must be at least 8 characters 40 Description This section is for an administrator to make notes Trap Notification Receiver IP Address This section is to set receivers IP address for receiving traps sent by NetAgent It is valid for up to 8 IP Addresses Community This section is to set a Community name for NMS The community name has to be as the same as the setting in NMS Trap Type This section is to select if send trap according to PPC MIB or RFC1628 Severity This section is to set Trap receiver levels There are three levels of Trap receiver e Information To receive all traps e Warning To receive only warning and severe traps e Severe To receive only severe traps Please refer to NMS manual for Trap levels Accept This section is to set to receive a trop or not Description This section is for an administrator to make notes Event This section is to select events for NetAgent to send traps Clicking on Select will open a Select Events List Or Click on Test is to send test trap Event Traps may be selected from this list Events list i
84. ty load voltage etc of the UPS by appearing with meters chart diagram Single Phase UPS Data Code Table 80 80 j 8 100 55 j 100 55 140 140 160 a 160 112 0 Input Volt 111 0 Output Volt Temperature 49 0 gp rane E PES i Z 9 Frequency oO Load 0 0 Capacity Single Phase UPS Data Graphics Iv Input Volt v Output Volt 160 E Temperature 140 Y M Load 120 M Capacity 100 80 60 40 20 EIGENS eerie ke Mice Single Phase UPS Data Graphics Li Information O Basic Advanced To use Advanced mode your browser must be able to access to the Internet 100 100 100 100 300 90 90 90 90 so eo eo feo Meter Chart pro 4170 LO 70 3 gt 200 o O Configuration i ooo Cy 3 Dn so gtso 9 50 Also 1 o 3 z Log Information t2 gi qj Ela P a 20 20 20 20 50 10 10 10 10 0 0 Lo 0 0 17 30 00 17 30 30 Input Volt Output Volt Temperature Frequency Load Capacity Time 1 Value 1 Time Value Time 1 Value 1 Input Volt V 17 28 42 0 08 00 00 0 172811 108 6 Output volti 17 29 42 0 08 00 00 0 172811 110 Temperature 17 29 42 0 08 00 00 0 172811 28 1 Frequency H2 17 29 42 0 08 00 00 0 172811 60 Load 17 29 42 0 08 00 00 0 172811 0 Capacity 17 28 42 0 08 00 00 0 172811 95 Fig 23 NetAgent 9 Meter Chart 29 Meter Chart Basic Advanced To use Advanced
Download Pdf Manuals
Related Search
Related Contents
Bulex-thermo manual german Petra WK 522.35 Samsung 27" podnikový monitor WQHD pro maximální produktivitu Uživatelská přiručka P Computador de pressão arterial Instruções de utilização DIABETES - Secretaria da Saúde L`AUTOMNE - Dominique SCHUELLER IBM G325-2585-02 User's Manual Copyright © All rights reserved.