1. Copyright 2008 Somfy SAS All rights reserved 5 Elixo 500 24 V Fitting the end limit brackets 1 2 3 4 Manually move the gate to the open position Position a bracket onto the rack so that it activates the motor end limit contact Screw the bracket onto the rack Manually move the gate to the closed position then repeat steps 2 and 3 to fit the second bracket to the rack Wiring General wiring diagram o aN E Nea D I e y lt che y y zZ a 2 LE a D E SHAI a AH SH gzh aA A Be je lo le e e O D oq if ts Re m s A 2 T 2 e E i352 8 lz lg gi om o on o gt 2 i gt 9 Saga 9 S x 3 als la ee E vo 9 Ig v E 7 AQ Bad gl 1 F 31 arm 230V G 32 es 33 gt e 34 Terminals Description Futon A B OV 24V COM
2. m E Le m Copyright O 2008 Somfy SAS All rights reserved T Elixo 500 24 V Memorising the remote controls To memorise a remote control 1 Press the PROG button on the control unit for 2 seconds The red indicator light will come on 2 Press a channel on the remote control to which the motorisation will be linked within 2 minutes The red indicator light flashes the remote control has been memorised If this procedure is carried out using a channel which has already been memorised this channel will be cleared To add other remote controls repeat the above procedure To add a Telis type remote control 1 Press the PROG button on the control unit for 2 seconds The red indicator light will come on 2 Press the PROG button on the back of the Telis This must be done within 2 minutes The red indicator light flashes the remote control has been memorised To exit programming mode without memorising a remote control briefly press the PROG button on the control unit Self learning AN The gate s travel self learning is essential when commissioning the motorisation During self learning the obstacle detection function is not active Remove any objects or obstacles and do not allow any persons near or inside the operating range of the motorisation To carry out an emergency stop during self learning use a memorised remote control Before beginn
3. SWC SWO ANT ANT 24 V SCA 24 V V Safe FAULT COM PED COM START CLOSE STOP PHOT BAR OPEN N L Aerial wiring For optimum reception the aerial must not be cut and must be as far away as possible from the power supply terminal blocks and wires The aerial must always be installed at a height and must be visible from a distance Do not fit the aerial to a metal post or behind a wire fence Cut the coaxial cable if it is too long Shortening the cable will improve the signal a coaxial wire which is too long extended or connected with an insulating screw joint will distort the signal The mounting plate is an active component of the aerial It must not be removed or modified Motor connection Secondary transformer Shared by end limit contacts Closing end limit contact Opening end limit contact 24 V output flashing orange light Aerial core Aerial braid Alternating 24 V output for power supply to the additional devices Gate status indicator output open closed Alternative 24 V output for power supply to and autotest of safety devices Input for safety devices autotest Shared by control inputs 18 20 Pedestrian opening control point input Shared by control inputs 22 23 24 25 26 Sequential operation control point input adjustable in the LoGic menu see pg 11 Control point input closing only Photoelectric cell input Safety edge sensor input Opening control point only
4. the mains or to a backup battery before installation is complete Be careful when handling the motorisation system to prevent any risk of injury In order to operate the motorisation must be supplied with 230 V 50 Hz The electric supply should solely be used for the motorisation e have a minimum cross section of 1 5 mm be fitted with an approved all pole switch with contact openings of at least 3 5 mm fitted with a protection device fuse or circuit breaker with a 16 A rating and a differential device 30 mA e be installed in accordance with the current electrical safety standards It is recommended that the installation be fitted with a lightning conductor in compliance with standard NF C 61740 maximum residual voltage 2 kV When installation is complete ensure that the mechanism is correctly set and that the gate changes direction when it encounters an obstacle Copyright O 2008 Somfy SAS All rights reserved Elixo 500 24 V Regularly check the condition of the gate Gates in poor condition must be repaired reinforced or even replaced Check that the various motorisation component s screws and fittings are correctly tightened Before carrying out any work on the installation switch off the power supply and or disconnect any backup batteries Motorising an existing gate Carry out a stress test with a measuring device which conforms to the requirements set out on in clause 5 1 1 of standard EN 12445 PRODUCT D
5. ESCRIPTION Contents of the standard kit Elixo 24 V Motor Keytis 2 RTS remote control RTS 3 m offset aerial Lag screws Nut Washer Plug Base plate Manual release handle assembly Handle locking key End limit brackets Description of the motorisation Motor Reduction unit with worm screws helicoid drive wheel Electro mechanical end limit unit Pinion Manual release mechanism Control unit Battery pack optional ref 9014612 fa 2 backup batteries 7b Battery holder tray 7c Battery power supply management card General motor size m amp gt aR o o IO V Q O 131 96 227 Copyright 2008 Somfy SAS All rights reserved 3 Elixo 500 24 V Area of application Sliding gates up to 500 kg and carrying out 30 operations per day To ensure the safety of all equipment and persons respect the information given in the table For a gate weighing use Ref 0 to 300 kg a passive rubber profile 9014597 on the end of the gate 300 to 500 kg a passive rubber profile 9014598 on the end of the gate LP If using a different rubber profile to those listed above ensure that the installation conforms with current regulations General view of a standard installation Motor Rack Aerial Amber light Set of photoelectric cells Keyswitch Passive rubber profile End limit brackets TO nmo O
6. Primary transformer 230 V Neutral single phase 230 V 50 60 Hz power supply Live single phase 230 V 50 60 Hz power supply Copyright 2008 Somfy SAS All rights reserved Elixo 500 24 V Connection to the power supply To connect the motor to the power supply use a standard multicore cable with a minimum cross section of 3x1 5 mm Inputs 23 24 and 25 must be bridged to terminal 21 if they are not used to connect a safety device Checking the motorisation wiring Motor connection Red 2 Blue 1 2 End limit connection 6 T 7 6 5 Switch on the power to the installation before commissioning QUICK COMMISSIONING Installer interface Parameter setting is carried out using the buttons on the control unit OK enter the menu and sub menu confirm a parameter setting OR select parameters modify a parameter value AND exit the active menu press simultaneously Language selection 1 Press the OK button Information is displayed on the screen information details pg 12 2 Press the OK button 3 Use the and buttons on the control unit to access the LANGUE Language menu 4 Press the OK button 5 Use the and buttons to access the required language 6 Press the OK button to confirm your selection 9 nn Y SSSS a El FE Ex
7. X gt End stops in the ground INSTALLATION N The motorisation must be disengaged during installation Assembling the manual release handle 1 Insert the release handle into the specific housing on the motor 2 Tighten the release handle 3 Fit the screw cover Disengaging the motorisation 1 Turn the key a quarter of a turn to the left 2 Turn the release handle to the right Do not forcibly push the gate Hold the gate over its entire travel during manual manoeuvres 4 Copyright 2008 Somfy SAS All rights reserved Elixo 500 24 V Installing the motorisation Fitting the mounting system The motor mounting kit provided is to be used on a concrete base For all other types of mounting use the appropriate fittings 1 Position the base plate e parallel to the gate with the symbol of the pinion pointing towards the gate by moving it by 25 mm in relation to the front line of the rack if the rack is fitted with a cover measure from the line on the rack not on the cover D gt j ay eet ora 4 fe 4 so that it does not obstruct movement and to ensure the gate is able to open and close completely 2 Mark the location for the ground mountings 3 Drill to a depth of 85mm 4 Insert the plugs 5 Tighten the lag screws on t
8. e warning the integrated flashing amber light comes on PrEAL approximately 3 seconds before motorisation starts OFF Without pre warning Without pre warning the integrated flashing amber light comes on when motorisation starts Sustained action ON Operation with sustained Operation in hold to run mode only with a wired control continuous hoLd to rUn action activated movement while the control button remains pressed OFF Operation with impulse action according to 3 or 4 step logic Copyright O 2008 Somfy SAS All rights reserved 1 1 Elixo 500 24 V Menu Display Value By Comments default START CLOSE selection ON the input between CLOSE the device connected between terminals 21 and 22 only StArt cLoSE terminals 21 and 22 operates enables the gate to be closed as CLOSE OFF the input between terminals 21 and 22 START the device connected between terminals 21 and 22 enables the motorisation to operate in sequential mode operates as START Pedestrian opening ON Activates the pedestrian Operation of the pedestrian opening pressing the button briefly PEdEStrlAn Opening opens the gate partially and pressing and holding the button opens OFF Deactivates the the gate fully pedestrian opening Fixed opening time 7 seconds Preset AEFAULLt to reset the motor factory default settings CLEARING THE REMOTE CONTROLS AND ALL SETTINGS Clearing all remote controls Press the PROG button on t
9. erating correctly keyswitch wired keypad etc START entry activated Check that the device controlling the START entry is operating correctly STOP entry activated Check that the device controlling the STOP entry is operating correctly PHOT entry activated Check that nothing is obstructing the photoelectric cells Check that the photoelectric cells are not dirty see guide for the cells CLOSE entry activated Check that the device controlling the CLOSE entry is operating correctly OPEN entry activated Check that the device controlling the OPEN entry is operating correctly Opening end limit entry activated Faulty electro magnetic detection system Replace it Closing end limit entry activated Faulty electromagnetic detection system Replace it Software thermal protection activated Wait until the message disappears before continuing to use the motorisation 1 2 Copyright 2008 Somfy SAS All rights reserved Elixo 500 24 V Display of the motor torque values during operation of the motorisation During the opening and closing phases four figures separated by a dot are displayed on the screen for example 35 40 The figures are updated whilst the gate is moving They represent the actual torque used 35 and the torque set during the self learning procedure 40 These values enable the torque entry to be corrected If the value of the actual torque used during movement of the gate more or less approaches the value of the pr
10. errupted return the gate to the closed position and restart self learning If the slowing down speed is subsequently changed self learning must be carried out again AT THIS STAGE IN THE INSTALLATION THE MOTORISATION IS OPERATIONAL MOTORISATION OPERATION See pages 2 and 3 in the user s manual CONNECTING ADDITIONAL DEVICES 24 V integrated flashing amber light ref 9 014 552 Photoelectric cells With autotest Without autotest 24V ac dc OV Activate the cell autotest function tESt Phot to ON in the LoGlc Deactivate the cell autotest function tESt Phot to OFF in the LoGlc menu menu Copyright 2008 Somfy SAS All rights reserved 9 Elixo 500 24 V Reflex photoelectric cell With autotest Without autotest dois 35019 ON OUTPUT MUTE CELLS OUTPUT Activate the cell autotest function tESt Phot to ON in the LoGlc Deactivate the cell autotest function tESt Phot to OFF in the menu LoGlc menu On the cell set the DIP switch1 to ON and the DIP switch2 to OFF On the cell set the DIP switch1 and the DIP switch2 to ON Wired keypad lol 22 M PTS CS RS T2 CM RY mi Ci ii V Copyright O 2008 Somfy SAS All rights reserved Elixo 500 24 V PARAMETER SETTING N If the parameters are changed after self learning has been carried out ensure the installation conforms to all relevant standards Menu Di
11. he motorisation control unit for more than 7 seconds The indicator light flashes to indicate that all remote controls have been cleared Clearing all settings 1 Press OK twice to access the menus 2 Use the and buttons to access the dEFAULt menu 3 Press OK to clear all settings The Elixo motorisation has been reset and returns to its original configuration factory default settings cee dEFRULE bLox gt Pro 0x Eza Before using the motorisation carry out a new self learning procedure see pg 8 DIAGNOSTICS Meaning of messages displayed on the screen Before accessing the menu list the control unit screen displays the following information e Somfy e Control unit software version e Number of cycles carried out expressed in hundreds during the first 100 manoeuvres the screen displays 0000 Whilst the motorisation is in use messages are displayed to show the system s status In the event of incorrect operation a message will be permanently displayed to show the device to be checked If the problem is not corrected or if it persists please contact Somfy technical assistance Message Meaning Permanent display Self learning successful Self learning unsuccessful Awaiting input of a value or function Exit programming mode Closing end limit activated Opening end limit activated Obstacle detected Pedestrian entry activated Check that the device controlling pedestrian entry is op
12. he threaded section for a rack height of between 110 and 130 mm il mm lt h lt 110 mm e the threaded section the unthreaded section for a rack 110 mm lt h lt 130 mm height of between 100 and 110 mm va _ To facilitate tightening of the lag screws use 2 nuts to form a double nut 6 Screw a nut onto each lag screw Va zN 100 lt h lt 130 7 E n e 7 Place the base plate onto the lag screws with the symbol of the pinion pointing towards the gate It must be a minimum of 23 mm from the ground Mounting the motor 1 Position the motor on the lag screws insert it and push it towards the gate 2 Ensure the pinion is correctly positioned under the rack 3 Set the height of the motor and or the rack to ensure a clearance of approximately 2 mm between the rack and the pinion This setting is important to prevent premature wear of the pinion and rack the pinion must not be supporting the weight of the gate 4 Check that the setting nuts all come into contact with the base of the motor e the motor is level e the gate runs correctly the clearance between the rack and pinion does not vary significantly over the gate s travel 5 Fit a washer and nut onto each lag screw in order to fit the motor
13. ing self learning Ensure the rail is clean Manually move the gate to the closed position Re engage the motorisation 1 Turn the release handle to the left 2 Move the gate manually until the drive mechanism re locks 3 Turn the key a quarter of a turn to the right SuC closing end limit activated should be displayed on the moto risation screen If SuO opening end limit activated is displayed check the motorisation wiring see pg 7 Start self learning Self learning comprises 2 cycles 1 cycle 1 opening 1 closing e The 1st cycle is carried out without slowing down and enables the motor to memorise the gate s entire travel The 2nd cycle includes slowing down in order to establish the minimum torque value needed for movement of the gate 1 Press the OK button on the control unit twice to access the menus ok 0x 2 Use the and buttons on the control unit to access the AutoSet Lx menu T E 3 Press the OK button to confirm Self learning has started The gate must complete 2 full cycles Copyright O 2008 Somfy SAS All rights reserved Elixo 500 24 V If self learning is correct OK is displayed on the motorisation screen If self learning has failed KO is displayed on the motorisation screen Check the following before restarting self learning e the gate runs correctly there is nothing obstructing the photoelectric cells if fitted If self learning is int
14. m 25 W 250VT0 62AandT1A RTS 36 433 42 Mhz 50 Ohm RG58 Elixo 500 24 V 14 Copyright 2008 Somfy SAS All rights reserved
15. ogrammed torque operating faults may occur in the future due to wear or slight warping of the gate If the value of the actual torque used exceeds the value of the programmed torque the gate will stop and reverse by several centimetres TECHNICAL SPECIFICATIONS Power supply Motor power supply Motor revolutions Power consumption Maximum consumed current Reduction ratio Revolutions at output Pinion Gate speed Maximum weight of the gate Maximum torque Lubrication Manual manoeuvres Obstacle detection Number of cycles day Control unit Backup batteries optional Operating temperature Index protection rating Weight Dimensions ELECTRONICS Accessories power supply Automatic closure time Operating time Pedestrian opening time Reversal pause Integrated flashing amber light connection Fuses Built in radio receiver Number of memorizable remote controls RTS remote control frequency Aerial resistance Copyright 2008 Somfy SAS All rights reserved 230 V 50 60 Hz 24 Vdc 3500 rpm 70 W 0 5 A 23 Vac 1 A 110 Vac 1 44 79 rpm 4 mm module 14 teeth 12 m min 500 kg 20 Nm Permanent grease Mechanical release with handle Electronic torque limiter 30 Built in with LCD display Two 12 V 1 2 Ah batteries 20 C to 60 C IP24 7 kg 70 N see General motor size pg 3 24 Vac 180 mA between 3 and 120 seconds 120s 7 seconds fixed 1 second approximately 24 V maximu
16. peed time must be set to 12 seconds Slowing down speed 0 No slowing down 0 Normal speed SLow SPEED 1 Slowing level 1 1 2 1 Average speed 2 Slowing level 2 1 3 2 Slow speed 3 Slowing level 3 1 4 3 Very slow speed Logic LoGlc to select the motor operating mode and devices Automatic closure tcA ON Activates automatic no The gate closes automatically after the programmed time delay closure OFF Deactivates automatic closure o la 3 STEP operation in semi automatic mode see User s manual pg 3 3 STEP OFF Activates the 4 step logic 4 STEP operation in sequential mode see User s manual pg 3 o E a IbL oPEn OFF None Photoelectric cell ON In closing mode only In closing mode the gate stops then reverses its movement operation In opening mode cells are inactive Photoc oPEn OFF In opening and closing In closing mode the gate stops and reverses its movement once mode the cells are no longer obstructed In opening mode the gate stops then continues its movement once the cells are no longer obstructed Photoelectric cell test ON Activates the cell autotest See the diagram for connection of the cells with autotest pg 9 and 10 tESt Phot function OFF Deactivates the cell autotest function Gate open indicator ON The output between ScA 2ch terminals 14 and 15 has been configured as the gate open indicator Pre warning ON With pre warning With pr
17. rance to ensure regular silent movement e End stops must be installed on the ground at both the opening and closing stop positions The position in which the motorisation mechanism will be fitted must allow for safe and easy manual release If after evaluation the gate system does not meet the conditions set out above it must be repaired or if necessary replaced The selected safety accessories for the installation must comply with the current standards and regulations in force in the country in which the product is being installed Ensure that there are no danger zones risk of crushing cutting trapping between the gate and the surrounding fixed elements caused by the opening movement of the gate On a barred gate if the bars are more than 40 mm apart install an appropriate safety device to prevent cutting Maintain a clear area of 500 mm behind the gate when it is completely open Take care while the gate is moving Place the fixed control devices and remote controls out of the reach of children Any switch without a locking device must be installed in direct view of the gate and away from any mobile parts The minimum height at which it must be installed is 1 5 m It must not be accessible to the public During installation of the motorisation Remove any jewellery bracelets chains etc For drilling and welding operations wear special glasses and sufficient protection Use the appropriate tools Do not connect to
18. sions of Directive 1999 5 EC A Declaration of Conformity is available at the web address www somfy com ce Elixo 500 24 V Suitable for use in EU CH and NO SAFETY General information Always read this installation manual and the safety instructions before installing this Somfy product This Somfy product must be installed by a professional motorisation installer for whom these instructions are intended The use of any safety components not approved by Somfy remains the sole responsibility of the installer These instructions describe how to install commission and operate this product Moreover the installer must comply with current standards and legislation in the country in which the product is being installed and inform his customers of the conditions for use and maintenance for the product Any usage outside of applications defined by Somfy constitutes non compliance and is therefore not covered by the guarantee In this event as for all usage not consistent with the instructions given herein Somfy accepts no responsibility for harm or damage Safety instructions Before installation ensure that the gate frame conforms to current standards particularly The gate sliding rail must be straight and horizontal and the wheels must be able to support the weight of the gate The gate should move easily over its entire travel distance and there should be no sign of excessive side sway The upper guide should allow the gate exact clea
19. somfy com Elixo 500 24 V TEN Installation manual TES Manual de instalacion PT Manual de instala o EL EYXEIPIDIO EYKAT OTAONG CONTENTS GENERAL INFORMATION SAFETY General information Safety instructions Motorising an existing gate PRODUCT DESCRIPTION Composition of the kit Description of the motorisation General motor size Area of application General view of a standard installation INSTALLATION Assembling the release lever Disengaging the motorisation Installing the motorisation Wiring QUICK COMMISSIONING Installer interface Language selection Memorising remote controls Self learning MOTORISATION OPERATION CONNECTING ADDITIONAL PERIPHERALS 24 V integrated flashing amber light Photoelectric cells Reflex photoelectric cell Wired keypad Wired keyswitch PARAMETER SETTING CLEARING REMOTE CONTROLS AND SETTINGS Clearing all remote controls Clearing all motorisation settings DIAGNOSTICS Meaning of messages displayed on the screen Display of the motor torque values during operation of the motorisation TECHNICAL SPECIFICATIONS Copyright 2008 Somfy SAS All rights reserved Elixo 500 24 V oo O1 BB BR KR BROW W W NNN NO o ONNN Elixo 500 24 V GENERAL INFORMATION This product installed in accordance with this guide complies with EN 12453 and EN 13241 1 standards Somfy hereby declares that this product complies with the essential requirements and other relevant provi
20. splay Value By Comments default Language LANGUAGE to select the language for displaying information on the control unit screen French Fra English Eng Spanish Esp German Deu Italian Ita Self learning AutoSet to start self learning for the gate travel Parameters PArAM to change the torque speed and slowing down values for the motorisation Automatic closure time Between 3 and 120 seconds Setting the time delay for automatic reclosing If tcA is activated in tcA LoGic Opening motor torque Between 1 and 99 The setting for the minimum motor torque value needed to move the oP t gate is carried out during auto programming Closing motor torque Between 1 and 99 Refer to the paragraph entitled Display of the motor torque values cLS t during operation of the motorisation pg 13 to set the motor torque Opening motor torque Between 1 and 99 values while slowing down oP t Slow Closing motor torque Between 1 and 99 while slowing down cLS t SLow Normal opening speed Between 1 second and 2 The slowing down time during opening and closing can be set by time norM oP SPEED minutes changing the normal speed time the higher the normal speed Normal closing speed Between 1 second and 2 travel the shorter the slowing down time time norM cLS SPEED minutes E g if the duration of an opening manoeuvre is 15 seconds for a slowing down time of 3 seconds the normal s
Download Pdf Manuals
Related Search
Related Contents
Manual - Prominent Fluid Controls Australia 861 Ko - Fnogec HAUTS DE CUISSES DE POULET AU MIEL ET À L`AIL Garmin Part 23 AML STC Checklist Changes Sheet 039 KESO Biokey OBLONG ULTRASONIC WAND USER MANUAL 製品仕様書 Aparatos para regulación y control Guía de inicio rápido Caja de conexiones certificada Jabra c330 GPS Receiver User Manual Copyright © All rights reserved.