Home
User`s Manual
Contents
1. OUT Stereo LINE OUT level setting When you turn ON OFF the device the level must be adjusted to zero 8 SWITCH ON OFF ON OFF power switch The led lights when the power is on 9 RACK MOUNTABLE Holes for 19 rack mounting Back 10 AC INPUT Socket for connection of the mains cable also contains the fuse compartment Before any connection check the mains voltage When replacing the fuse use a fuse with the same characteristics 11 DC POWER 24V Terminals for back up power supply 24 V DC In the event of main power failures the DC power takes over automatically When connecting observe the correct polarity 12 LINE OUT MASTER Balanced stereo output XLR 13 MONO OUT Unbalanced mono output 6 35 mm Jack 14 MIC OUT Unbalanced output 6 35 mm Jack allocated exclusively to inputs 1 to 6 when the switch 3 is turned ON 15 REC OUT Unbalanced stereo output RCA Intended for recording Controls Back 16 LINE INPUTS Unbalanced stereo inputs RCA Intended for the connection of stereo sources CD DVD MP3 etc 17 LINE 24V MIC Selectors of 3 input types e Line Electret microphone with 24 V phantom power supply Dynamic microphone 18 MIC LINE INPUTS Balanced unbalanced stereo inputs combo XLR 6 35 mm Jack 19 MIC 1 PRIORITY Adjusts the attenuation level when the priority input is active The signal of inputs 2 to 11 12 is completely attenuated when the setting is
2. AUDIO EE POLE MIX 7 12 CHANNEL MIXER USER S MANUAL Important Safety Instructions CAUTION 5 RISK OF ELECTRIC SHOCK NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN MOISTURE This symbol wherever used alerts you to the presence of un insulated and dangerous voltages AN within the product enclosure These are voltages that may be sufficient to constitute the risk of electric shock or death This symbol wherever used alerts you to important operating and maintenance instructions POWER SUPPLY Ensure that the insource voltage AC outlet matches the voltage rating of the product Failure to do so could result in damage to the product and possibly the user Unplug the product before electrical storms occur and when unused for long periods of time to reduce the risk of electric shock or fire EXTERNAL CONNECTION Always use proper ready made insulated mains cabling power cord Failure to do so could result in shock death or fire If in doubt seek advice from a registered electrician DO NOT REMOVE ANY COVERS Within the product are areas where high voltages may present To reduce the risk of electric shock do not remove any covers unless the AC mains power cord is removed Covers should be removed by qualified service personnel only No user serviceable parts inside FUSE To prevent fire and damage to the product use only the recomme
3. d by observing the safety instructions in this operating manual 2 The device was not diverted from its destination either voluntary or accidental and suffered no deterioration or modification other than those described here or explicitly authorized by AUDIOPOLE All modifications or repairs have been carried out by an authorized service station 4 The defective product must be returned with the dealer who made the sale or to an authorized service station with proof of purchase 5 The device was properly packaged to avoid damage in transport AUDIOPOLE 22 rue Edouard Buffard Z A C de la Charbonni re Mont vrain 77771 Marne la Vall e Cedex 4 France T l 33 0 1 60 54 32 00 Fax 33 0 1 60 54 31 90 www audiopole pa fr www audiopole fr
4. ion Thank you for purchasing AUDIOPOLE MIX 7 The device is a compact mixer designed for multiple applications including AV and conference Features 6monoinputs including 1 priority IN 3stereoinputs Stereo output Mono output Micro output 3bandEQ Individual phantom power e Back up power supply 24 V DC Controls Front m am EU i 42 O8 as CH TAZ auo TAN JA AAN GS JAS AN AR ASN AS ASN a e telg ole Velg c o o Velg e tele jam s 2o me so sia so o a TU val a 2 3 5 7 1 CH 1 CH 11 12 Volume of Mic Line inputs 1 to 6 and stereo inputs 7 8 to 11 12 2 SIG LEDs indicating the presence of the signal the light intensity is proportional to the input level 3 MIC OUT ON OFF On ON position inputs 1 to 6 are assigned to the MIC OUT exclusively with independent level setting Attention the EQ and the priority function do not work on this output 4 EQ 3 bands EQ only active for MONO LINE OUT MASTER and RECORD OUT outputs The frequency ranges are centered respectively on 80 Hz LOW 2 5 kHz MID and 12 kHz HIGH Controls Front 5 MONO OUT MONO output level setting 6 L RINDICATOR Colored LEDs displaying the output LINE OUT MASTER level The red LEDs clip indicate the presence of saturation then adjust the levels accordingly 7 MASTER
5. maximum attenuation is disabled when the setting is at a minimum 4 Diagram Technical specifications 0055 HD Max gain 60 dB CH MIC INPUT LINE OUT 50 dB CH MIC INPUT REC OUT 60 dB CH MIC INPUT MIC OUT 60 dB CH MIC INPUT MONO OUT Max gain 20 dB CH MIC INPUT LINE OUT 10 dB CH MIC INPUT REC OUT 20 dB CH MIC INPUT MIC OUT 20 dB CH MIC INPUT MONO OUT Stereo inputs CH7 8 C11 12 Sonia baled 20 Hz 22 Wie 3 cB lt 000 fie EE Max gain 20 dB CH LINE OUT 10 dB CH gt REC OUT 14 dB CH MONO OUT 105 dB Mic inputs 14 kQ Impedances Other inputs 10 KQ or plus REC OUT 1 ka Other outputs 1200 High 15dB 12 kHz Medium 12dB 2 5 kHz Low 15dB 80 Hz We STEREO U Input output lt 72 dB 1kHz STEREO UR CH1 CH 6 LINE OUT 0 dBu 2dB balanced XLR MONO OUT MIC OUT 0 dBu 2dB unbalanced 1 4 Jack Max output level 20 dBu balanced unbalanced 1 4 Jack Noise level lt 80 dB 20 Hz 22 kHz input and output levels at 0 dB fat EQ other levels to min Other supply 24V DC Dimensions LxHxP 483K 44x 195mm Weight Ne 29 Warranty This device is warranted parts and labor against any manufacturing defects for a period of two years from the date of purchase by the first user Conditions 1 The unit has been installed and implemente
6. nded fuse type as indicated in this manual Do not short circuit the fuse holder Before replacing the fuse make sure that the product is OFF and disconnected from the ACD outlet PROTECTIVE GROUND Before turning the unit on make sure that it is connected to Ground This is to prevent the risk of electric shock Never cut internal or external Ground wires Like wise never remove Ground wiring from the Protective Ground Terminal OPERATING SAFETY INSTRUCTIONS Read these instructions Follow all instructions Keep these instructions Do not discard Heed all warnings Only use attachments accessories specified by the manufacturer POWER CORD AND PLUG Do not tamper with the power cord or plug These are designed for your safety Do not remove Ground connections If the plug does not fit your AC outlet seek advice from a qualified electrician Protect the power cord and plug from any physical stress to avoid risk o electric shock Do not place heavy objects on the power cord This could cause electric shock or fire SERVICING Refer all servicing to qualified service personnel only Do not perform any servicing then those instructions contained within this User s Manual DISPOSAL This symbol indicates that the disposal of this product is submitted to local regulations Please contact your local dealer m Index de nto dU ada 2 Features E CONTOS EMT een 5 Technical Speciiiealions lidia O Introduct
Download Pdf Manuals
Related Search
Related Contents
Philips Zoom WhiteSpeed DIS577 PETS AND Weider WEEVSY1023 User's Manual QXvue(v1.1.1.x) User Manual for veterinary use User Manual - Accurate Laser Systems フェンダートリムレール 組付・取扱説明書 IMPRESSA E80/85 Modo de empleo Manitowoc Ice G-0400 User's Manual Untitled Copyright © All rights reserved.
Failed to retrieve file