DMK
Contents
1. 16 CONTROL PANEL MAINTENANCE TECHNICAL DATA AT cR 20 PROBLEMS AND 5 5 0 22 INDEX D SHUMIDIFICATEUR DE AIR 23 COMME SE PRESENTE D MARRAGE IMPORTANTES REGLES DE SURETE INSTALLATION 24 COLLECTE DE L EAU DE BUEE ssssessssssescssssecesssecessssecessnnecessnes 25 PANNEAU DE 26 ENTRETIEN DONNEES TECHNIQUES SCHEMAS ELECTRIQUES PROBL MES ET SOLUTIONS 31 INDEX ENTFEUCHTER TRAGBAR 32 32 INBETRIEBNAHME WICHTIGE SICHERHEITSHINWEISE INBETRIEBNAHME AUFSAMMLUNG DES 34 BEDIEN FELDER 35 ee ete 36 TECHNISCHE DATEN 37 SCHALTPLAN FEHLERBEHEBUNG NDICE DESHUMIDIFICADOR DE AIRE PORT TIL ssssees 41 COMO SE PRESENTA s ee tene eed 41 ARRANQUE ese 41 IMPORTANTES NORMAS DE 42 INSTALACI N RECOGIDA AGUA DE CONDENSACI N PANEL DE CONTROL 45 DATOS T CNICOS ois ee nanan adn det 46 ESQUEMAS EL CTRICOS esent 47 PROBLEMAS Y SOLUCIONES seen 49 INFORMAZIONI GENERALI Conservare il manuale in
2. Consists of a unit mounted on four rotating wheels and transport handle for easy movement of the unit from one room to another and a top mounted control panel for which is easily visible and accessible It is available in three models of different dehumidification capacities DMK12 DMK20 DMK24 14 STARTING Read the manual carefully and fully before first using the dehumidifier Lack of observation of the instructions may damage the unit and void the warranty Before connecting the dehumidifier ensure that It is located on a stable floor capable of supporting the weight of the dehu midifier with the condensate collec tion bucket full There is good airflow in the room Do not allow curtains or other objects block the intake or outlet air The condensate collection bucket is empty and correctly inserted 14 12 litres daily capacity 20 litres daily capacity 24 litres daily capacity The electrical cable is completely unwound The dehumidifier must always be kept vertical because it contains a refrig erant After removing the packaging leave it in a vertical position to allow the refrigerant to distribute correctly and wait two hours before starting When starting for the first time allow the dehumidifier to operate for 24 hours It is normal that the air around the dehumidifier in operation becomes warmer Better results are obtained locating the unit away from sources of h
3. Check that the float is correctly posi tioned for its normal operation If not carefully move it until correctly posi tioned 6 Refit the condensate collection bucket 4 Insert the cover as shown in the fig ure then press the back of the cover to lock the hooks in the holes of the condensate collection bucket Close the cover Aermec IDMKUJ 0113 5356200 01 15 17 CONDENSATE COLLECTION BUCKET The collection of condensate can be done in two ways 1 In the condensate collection bucket which has to be periodically emptied 2 Directly to a drain WARNING With either method the dehumidifier will not operate if the condensate collection bucket is not correctly fitted 1 EMPTYING THE CONDENSATE COLLECTION BUCKET If the tube for direct drain is not con nected the condensate is collected in the condensate collection bucket until it is full 4 9 litres When the conden sate collection bucket is full the indicator BUCKER FULL will light up and the dehu midifier will stop automatically See the paragraph CLEANING THE CONDENSATE COLLECTION BUCKET 2 DIRECT DRAIN The dehumidifier can be connected directly to a drain with a rubber tube of 14 mm internal diameter not pro vided thereby operating without the need to empty the condensate collec tion bucket WARNING DISCONNECT THE PLUG BEFORE CONNECTIN
4. for at least 24 hours to reach the desired humidity The air flow outlet is blocked Ensure that there are no curtains furniture or other objects blocking the intake or outlet of the dehumidifier See the section on Minimum clearance space The filter is dirty See the section on Cleaning and maintenance The humidity level set may not be sufficiently low To have drier air press the button and set a lower humid ity percentage or set the operating mode to CONTINUOUS for maximum dehumidification Doors and windows are not closed Check that all doors and windows are completely closed The drier is discharging humid air into the room Install the dehumidifier far from the drier The drier must discharge humid air outdoors The room temperature is too low The capacity of the dehumidifier is better at higher ambient temperatures Low ambient temperatures reduce the dehu midifier capacity The dehumidifier is designed to operate at temperatures greater than 5 C The dehumidifier works too hard The dehumidifier area is too big The capacity of the dehumidifier might not be sufficient The doors and windows are open Close all the external doors and windows Frost forms on the evaporating coil of the dehumidifier The ambient temperature is less than 5 C This is normal See the paragraph Automatic defrost The controls cannot be set When the compressor switches off the fan continu ous
5. luogo asciutto per evitare il deterioramento per almeno 10 anni per eventuali riferimenti futuri Leggere attentamente e completamente tutte le informazioni contenute in questo manuale Prestare particolarmente attenzione alle norme d uso accompagnate dalla scritta ATTENZIONE in quanto se non osservate possono causare danno alla macchina e o a persone e cose Per anomalie non contemplate da questo manuale interpellare tempestivamente il Servizio Assistenza di zona AERMEC S p A declina ogni responsabilit per qualsiasi danno dovuto ad un uso improprio della macchina ad una lettura parziale o superficiale delle informazioni contenute in questo manuale GENERAL INFORMATION Keep the manual in a dry place to avoid deterioration for at least ten years for any future reference Carefully and thoroughly read all the information contained in this manual Pay particular attention to the usage regulations accompanied by the word WARNING because if they are not complied with damage can be caused to the machine and or injury to persons or damage to property may result If any malfunctions are not included in this manual contact the local After Sales Service immediately AERMEC S p A declines all liability for any damage due to improper use of the machine or the partial or superficial reading of the information contained in this manual INFORMATIONS G N RALES Conserver les manuels dans un endroit sec afin d viter leur d t r
6. to work for around 3 minutes This is normal Wait for around 3 minutes and set the desired fan speed Water on the floor 22 The rubber tube for direct discharge may be loose Check the rubber tube for direct discharge connection See the paragraph Condensate water collection The condensate is to be collected in the bucket but the rubber tube for direct discharge is also connected If condensate is to be collected in the bucket remove the rub ber tube for direct discharge and insert the rubber plug in the outlet tube See the paragraph Condensate water collection The condensate is to be collected in the bucket the rubber tube for direct discharge is not installed but the rubber plug is not correctly inserted in the outlet tube Correctly insert the rubber plug into the outlet tube The float is not in the correct position Open the condensate collection bucket as described in the Installation paragraph and place the float in the correct position Aermec IDMKUJ 0113 5356200_01 dati tecnici riportati nella presente documentazione non sono impegnativi AERMEC 5 si riserva la facolt di apportare in qualsiasi momento tutte le modifiche ritenute necessarie per il miglioramento del prodotto Les donn es mentionn es dans ce manuel ne constituent aucun engagement de notre part Aermec S p A se r serve le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du p
7. 0113 5356200_01 DMK 18 CONTROL PANEL 2 or 4 hour start stop timer um low Fan speed high medi Condensate collection bucket full Continuous operation HUMIDITY gt Dehumidifier running Dirty filter WARNING WHEN THE CONDENSATE COLLECTION BUCKET IS FULL OR REMOVED NO CONTROLS CAN BE SET LEGEND ON OFF BUTTON Press the ON OFF button to start or stop the dehumidifier FILTER BUTTON After 250 hours of humidifier operation the FILTER RESET indicator will light up showing that the filter needs cleaning Remove and clean the filter See the paragraph on cleaning the filter o BUTTON Press to set the required Relative Humidity RH between 8096 and 3596 in steps of 596 Press the button until the 3596 level to use the CONTINUOUS operating mode which will be shown by the indicator lighting up In the CONTINUOUS operat ing mode the dehumidifier work continuously at maximum capacity if connected to the direct drain rubber tube or until the condensate collection bucket is full DISPLAY The display shows the required Relative Humidity RH and it is adjusted with the buttons During normal operation the display shows the actual Relative Humidity RH of the space with a tolerance of 5 SPEED BUTTON Press to set the fan speed HIGH MID Medium or LOW Select a HIGH speed for a quicker dehumidification of the air Once the required Relati
8. AERMEC n air conditioning MANUALE USO USER MANUAL MANUEL D UTILISATION HANDBUCH MANUAL USO DEUMIDIFICATORE PORTATILE PORTABLE DEHUMIDIFIER DESHUMIDIFICATEUR PORTABLE ENTFEUCHTER TRAGBAR DESHUMIDIFICADOR PORT TIL DMK12 DMK2O DMK24 FERE PAG 5 PAG 14 PAG 23 PAG 32 PAG 41 5 3 5 IDM 1 200 0 6 RMEC_ AERMEC S D 2 0 l PSE er quee ve roma DMK24 Telefax 39 0442 93730 39 0442 93566 www aermec com info aermec com DICHIARAZIONE DI CONFORMITA C Noi firmatari della presente dichiariamo sotto la nostra e risulta progettato prodotto e commercializzato soddisfacendo le lt esclusiva responsabilit che l oggetto cosi definito disposizioni delle seguenti normative comunitarie tutti i modelli deumidificatore portatile della serie conforme alle 76 seguenti direttive Direttiva Bassa Tensione LVD 2006 95 60335 2 40 55014 1 Direttiva Compatibilita Elettromagnetica 2004 108 CE EN 62233 EN 55014 2 EN 61000 3 2 EN 61000 3 3 DECLARATION OF CONFORMITY We the undersigned declare under our sole responsibility that the object de and is designed produced and marketed in compliance with the pro fined as follows visions of the the following community standards all the models dehumidifier portable DMK complies with the following directi
9. G THE DEHUMIDIFIER TO THE DRAIN Do not remove the condensate collec tion bucket when the dehumidifier is in operation or when it has just been switched off condensate water level DMK To connect to the drain follow these instructions 1 Open the cover on the side of the dehumidifier 2 Remove the rubber plug 3 Manually insert the rubber tube to the drain outlet connection Ensure there are no leaks 4 Periodically check the condensate drain system is working correctly WARNING Ensure the condensate drain tube remains below the outlet level of the unit so that there is a slope for the condensate to drain naturally WARNING To revert to the normal drain method stop the dehumidifier wait until the drain tube is completely empty otherwise the water will drain without being collected in the conden sate collection bucket Remember to refit the rubber plug to the outlet tube OK 16 Aermec IDMKUJ
10. eat and keeping doors and windows closed Place the dehumidifier in a space where the temperature is not less than 5 Do not use outdoors IDMKUJ 0113 5356200 01 DMK 15 IMPORTANT SAFETY INSTRUCTIONS IF USED IN A BATHROOM ENSURE NO WATER ENTERS THE UNIT The units must not be connected to a multi way socket and the power cable must not pass underneath a carpet Do not pull the electrical cable to remove the plug Never disconnect the power cable whilst the dehumidifier is operating this might damage the unit s electronic circuit boards This dehumidifier is only for domestic use residences offices shops any other use is considered improper Do not disassemble or attempt to repair the dehumidifier This may only be done by an Authorised Service Centre Do not use the unit in the event of a 16 INSTALLATION Before starting the dehumidifier it is necessary to carry out some prelimi nary operations to the condensate collection bucket 1 Remove the condensate collection bucket as shown in the figure 2 Push the sides of the condensate collection bucket to unhook the two hooks of the cover then remove the cover 3 Check there are no foreign objects in the condensate collection bucket malfunction or if it appears damaged disconnect the plug and ask assistance from an Authorised Service Centre Do not try to move the dehumidifier on top of carpets or other objects 5
11. f the unit Hooks for filter removal Hooks to wind up the power supply cable DMK Aermec IDMKUJ 0113 5356200 01 DMK 20 TECHNICAL DATA Dehumidification capacity I 24h Dehumidification capacity I 24h 4 3 11 5 13 2 Sound power level max med min dB A 53 51 49 55 53 51 57 55 53 Sound pressure level max med min dB A 43 41 39 45 43 41 47 45 43 Air flow max med min m3 h 150 120 100 150 130 115 190 170 145 Condensate collection bucket capacity 4 9 Power supply V Hz 230V 50Hz Power input Ww 380 Current input 1 7 Rated input power 480 Refrigerant R134a Refrigerant charge g 0 20 Net weight Gross weight kg 1 Indoor air temperature 30 C d b 27 C w b 2 Indoor air temperature Tested in accordance with EN 810 27 C d b 21 C w b 3 Sound pressure level measured in a semi anechoic chamber front distance 1m 4 Tested according to EN 60335 DIMENSIONAL DATA 343 mm FAAA 270 mm MINIMUM CLEARANCE SPACE gt 40cm Aermec IDMKUJ 0113 5356200_01 19 DMK 21 WIRING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION orange brown purple blue white black yellow compressor red earthing yellow gree
12. ioration pendant au moins 10 ans pour toutes ventuelles consultations futures Lire attentivement et enti rement toutes les informations contenues dans ce manuel Pr ter une attention particuliere aux normes d utilisation signal es par les inscription ATTENTION car leur non observance pourrait causer un dommage l appareil et ou aux personnes et objets Pour toute anomalie non mentionn e dans ce manuel contacter aussit t le service d assistance de votre secteur AERMEC S p A d cline toute responsabilit pour tout dommage une utilisation impropre de l appareil et une lecture partielle ou superficielle des informations contenues dans ce manuel ALLGEMEINE INFORMATIONEN Die Handb cher an einem trockenen Ort aufbewahren damit es mindestens weitere 10 Jahre f r eventuelle Informationen einsehbar ist Alle in diesem Handbuch enthaltenen Informationen aufmerksam und vollst ndig lesen Achten Sie insbesondere auf die Benutzungsanweisungen mit den Hinweisen ACHTUNG da deren Nichtbeachtung Sch den am Ger t bzw Sach und Personensch den zur Folge haben kann Wenden Sie sich bei Betriebsst rungen die in diesem Handbuch nicht aufgef hrt sind umgehend an die zust ndige Kundendienststelle Die AERMEC S p A bernimmt keine Haftung f r Sch den aus dem unsachgem fsen Gebrauch des Ger tes und der teilweisen oder oberfl chlichen Lekt re der in diesem Handbuch enthaltenen Informationen INFORMACI N GENERAL Conse
13. n ere eth a eee amt ear eg See en ee ee ee me Pc ee oe EH uc e DMK12 DMK20 DMK24 WATER LEVEL SWITCH TUBE ROOM SA TEMPSENSOR TEMP SENSOR COM lt NO 0 6 i FAN RT RT BU BN en A A CN3 gt gt E CN3 is LANGER YEON M ACL o L T Mb YEGN 4 RD BU ST ji POWER SAT BU HUMIDITY SENSOR PE YEGN O PE ELECTRIC BOX ee ee 20 Aermec IDMKUJ 0113 5356200_01 DMK IF THE DEHUMIDIFIER IS NOT USED FOR SOME TIME If the dehumidifier will not be used for a long period of time then before storage ensure that 1 Switch it off remove the plug and fold the cable carefully 2 Completely empty the dehumidifier of any water empty the condensate collection bucket and dry any remaining water with a cloth 3 Remove any condensate discharge tube and close the outlet pipe with the rubber plug 4 Refit the bucket 5 Remove and clean the filter with a vacuum cleaner If the filter is very dirty clean it with tepid wate
14. ng with the same setting as before the power interruption 17 19 MAINTENANCE CARE AND CLEANING THE DEHUMID IFIER Before commencing any operation stop the dehumidifier and disconnect the electrical plug CLEANING THE CASING AND GRILLE Use water and a delicate detergent Do not use bleach or abrasive cleaners To clean the grille use a vacuum cleaner or a brush CLEANING THE CONDENSATE COL LECTION BUCKET Every two weeks clean the condensate collection bucket to prevent the growth of mould mushrooms and bacteria Remove it from the dehumidifier as de scribed earlier empty it and partially fill with clean water and add some delicate detergent Empty and rinse WARNING Do not use a washing ma chine to clean the condensate collec tion bucket Correctly refit the condensate collec tion bucket AIR FILTER CLEANING The air filter must be checked and cleaned frequently for the unit to func tion correctly After about 250 hours of operation the FILTER RESET indicator will light up to remind to clean the filter Remove the filter pressing the two hooks see the figure beside remove clean with tepid water and soap rinse and allow to dry before refitting Start the dehumidifier and press the FILTER button to switch off the FILTER RESET indicator WARNING Do not wash the filter in a washing machine 18 WARNING Do not use the dehumidi fier without a filter because the dirt will affect the performance o
15. objeto definido de la siguiente manera disposiciones de las siguientes normativas comunitarias todos los DMK deshumidificador portatil cumple con las siguientes directivas modelos 5 Equipos de Baja Tensi n Directiva LVD 2006 95 EN 60335 2 40 EN 55014 1 Directiva Compatibilidad Electromagn tica 2004 108 EC EN 62233 EN 55014 2 61000 3 2 61000 3 3 Bevilacqua 18 01 2013 La Direzione Commerciale Luigi Zucchi 7 ig 095 0797 cO cp eoo ET e e 0 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 INDICE DEUMIDIFICATORE D ARIA PORTATILE eene 5 COME SI PRESENTA 5 oa eni ricette erra se eei on 5 IMPORTANTI NORME DI SICUREZZA 6 INSTALLAZIONE RACCOLTA DELL ACQUA DI CONDENSA PANNELLO COMANDI MANUTENZIONE 2200 9 10 SCHEMI nennt 11 PROBLEMI E SOLUZIONI 13 INDEX PORTABLE AIR DEHUMIDIFIER DESCRIPTION STARTING ccce pari tice trm ee a tem ed a eid 14 IMPORTANT SAFETY 5 15 INSTALLATION inocente Pr Pe pea 15 CONDENSATE COLLECTION
16. r and a neutral soap and dry it before refitting 6 Protect the dehumidifier from dust with suitable packaging and store in a clean and dry environment Aermec IDMKUJ 0113 5356200_01 21 22 PROBLEMS AND SOLUTIONS PROBLEM POSSIBLE CAUSE WHAT TO DO The dehumidifier does not start The dehumidifier is not correctly connected to the power supply DMK Ensure that the dehumidifier plug is correctly inserted in the socket The dehumidifier has reached the desired humidity level or the condensate collection bucket is full The dehumidifier switches off automatically when these two conditions occur Set a lower humidity level or empty the condensate collection bucket and re insert it correctly The condensate collection bucket is not in the cor rect position Position the condensate collection bucket correctly The float is not in the correct position Open the condensate collection bucket as described in the Installation paragraph and place the float in the correct position Interruption and then the electrical power is reap plied When electrical power is reapplied it is normal for the unit starts to dehumidify correctly after 3 minutes The protective system ensures that there is a 3 minute time delay before starting the compressor to avoid overloads The dehumidifier does not dehumidify the air as it should Not enough time has passed to ensure the removal of humidity On first starting allow to operate
17. roduit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce at any time whatever modifications deemed necessary to the improvement of the product Im Sinne des technischen Fortsschrittes beh lt sich Aermec S p A vor der Produktion nderungen und Verbesserungen ohne Ank ndigung durchzuf h ren Los datos t cnicos de este documento no son vinculantes AERMEC S p A se reserva el derecho de realizar en cualquier momento las modificaciones que considere necesarias para mejorar el producto AERMEC S p A 37040 Bevilacqua VR Italia Via Roma 996 Tel 39 0442 633111 Telefax 39 0442 93730 39 0442 93566 www aermec com
18. rve el manual en un lugar seco durante al menos 10 a os para evitar su deterioro para poder consultarlo en el futuro Lea atenta y completamente todas las informaciones contenidas en este manual Preste particular atenci n a las normas de uso acompa adas de las indicacione ATENCI N puesto que si no se cumplen pueden causar el deterioro de la m quina y o da os personales y materiales En caso de anomal as no contempladas en este manual contacte inmediatamente con el Servicio de Asistencia de su zona AERMEC S p A declina cualquier responsabilidad derivada de cualquier dafio debido a un uso impropio de la m quina o bien de una lectura parcial o superficial de la informaci n contenida en este manual 12 PORTABLE AIR DEHUMIDIFIER We thank you for your purchase of an Aermec DMK portable dehumidifier Manufactured from superior materials in strict compliance with safety stand ards the DMK is easy to use and will last a long time The Aermec DMK portable dehumidi fier is a unit which brings humidity levels to comfort value for domestic environments Versatile and easy to use it can be used in bedrooms basements bath rooms and in rooms where laundry is dried in order to reduce humidity lev els to ideal values High humidity levels are a source of discomfort and can degrade the house by causing mould 13 DESCRIPTION DMK Dehumidified air outlet
19. ve Humidity RH is reached set the fan speed to MID or LOW to have a quieter unit operation Q TIMER BUTTON If the unit is running press the TIMER button once and the unit will stop after 2 hours press the button twice and the unit will stop after 4 hours If the unit is off standby press the TIMER button once and the unit will start after 2 hours press the button twice and the unit will start after 4 hours OTHER CHARACTERISTICS Indicator BUCKET FULL lit The lit indicator shows the 1 Condensate collection bucket full 2 Condensate collection bucket missing 3 Condensate collection bucket not cor rectly fitted Alarm If the condensate collection bucket is full or missing for more than three minutes and alarm will sound for around 10 sec onds to show that it requires emptying Aermec IDMKUJ 0113 5356200 01 and or repositioning Automatic stopping The water level sensor stops the dehu midifier when the condensate collection bucket is full or when it has been removed or when not correctly fitted Automatic defrost When frost forms on the evaporating coil the compressors automatically stops and the fan continuous to run until the frost is completely thawed from the evaporating coil Afterwards the compressor will start and operate normally Power supply interruption In the event there is an interruption of the power supply the unit will restart au tomatically when power is reapplied and continue runni
20. ves E Low Voltage Directive LVD 2006 95 EC EN 60335 2 40 EN 55014 1 Electromagnetic Compatibility Directive 2004 108 EC EN 62233 EN 55014 2 61000 3 2 EN 61000 3 3 CERTIFICAT DE CONFORMITE Nous soussign s d clarons sous notre seule responsabilit que l objet d fini et est concu produit et commercialis conform ment aux disposi comme suit tions des normatives communautaires suivantes tous les mod les T DMK d shumidificateur portatif est conforme aux directives suivantes G C Directive Basse Tension LVD 2006 95 EC EN 60335 2 40 EN 55014 1 Directive Compatibilit Electromagn tique 2004 108 62233 55014 2 iL EN 61000 3 2 EN 61000 3 3 KONFORMITATSERKLARUNG Wir die Unterzeichner erkl ren unter unserer alleinigen Verantwortung dass sowie unter Einhaltung der folgenden gemeinschaftlichen Bestim das Objekt wie folgt definiert mungen entworfen hergestellt und vertrieben wird alle Modelle QD Entfeuchter tragbare entspricht den folgenden Richtlinien 5 n Niederspannungsrichtlinie LVD 2006 95 EN 60335 2 40 EN 55014 1 5 Richtlinie zur elektromagnetischen Vertraglichkeit EMC 2004 108 EC EN 62233 55014 2 61000 3 2 61000 3 3 DECLARACION DE CONFORMIDAD 6 Los abajo firmantes declaramos bajo nuestra nica responsabilidad que el y resulta proyectado producido y comercializado satisfaciendo las
Download Pdf Manuals
Related Search
DMK dmk airport dmk skin care dmk enzyme therapy dmk doterra dmk party dmk extraction tool dmk wiki dmk airport code dmk silver feather dmk don mueang dmk pharmaceuticals dmk laser dmk burger bar chicago il dmk development group dmk thailand dmk advisor group dmk dairy dmk cargo dmk silver feather smart dc reel dmk bremen dmk india dmk don mueang airport dmk fandom dmk tamil nadu dmk portal login
Related Contents
Kramer Electronics VP-5XL 1:5 VGA/UXGA Distributor Toto MioMore Desktop User Manual - US English HP LaserJet User Guide – ITWW Kid tracker 401_20140530.ai User Manual for the CALL courseware development Template Pretec i-Disk Lock MC-1 Manual - Carousel USA BAÑOS TERMOSTÁTICOS DIGITALES DIGITAL Copyright © All rights reserved.