Home
Page 1 Page 2 Preface Thank you for purchasing our GSM Security
Contents
1. Enabling Landline Phone neret Ringtone Times for Landline Phone Alarm eene yum Wireless Signal Output from the Main 1 Networking Center Settings networking functions customized Main Device Status eene NN TET Daily Operations eese nennen tenente nnne nennen Home 10 iau Da a ER To E faa 10 Answetttig Call ABIT or riot eei eram 10 Remote Conto oir riiv imc aar etes te hua 10 M o e anr 11 e 11 System Inspection enne a a i HE oen RENDUM 11 Precautiolis E e ntt TS 12 Technical Parameters eee ette ettari venen 12 Introduction to Functions With dual network of GSM telephone cable the System is more secure and reliable With the quad band GSM module for global use Includes 2 wired zones and 99 wireless zones Supports code pairing with 8 wireless remote controllers at the most LCD screen with a built in clock With voice prompts for easy operations Supports an extemal intercom speaker GSM SECURITY ALARM SYSTEM Supports 3 groups of timed arming and 3 groups of timed disarming The main device can dial alarm calls to 6 preset phone num
2. Setting steps press the 0 key on the keypad of the main device the main device will make a sound of Beep once per second After the specific time the ARM indicator lamp will stay on Now this function is successfully activated Home Arming When you re at home some detectors need to be activated such as doors windows balconies perimeters etc But there s no need to keep other detectors activated e g you may trigger the detector in the living room Thus it is suitable to enable the Home Arming function Setting steps press the 9 key on the keypad of the main device and the corresponding indicator lamp stays on Then this function is successfully activated Operation on the main device press the 0 key to the main device to the Home Arming status Operation by the remote controller press the 4 key on the remote controller Disarming If this function is activated the main device is out of alarm state There are two conditions to enter this state 1 normal disarming after arming 2 disarming to stop an alarm After disarming the zones excluding the 24h zones are idle Setting steps input the User Password and press the key to confirm After the Away or Home indicator lamp goes off the function is successfully activated Operations by the remote controller press the 8 key on the remote controller Operations on the main device User Password 8 GSM SECURITY ALARM SYST
3. Ringtone Times 72 1 9 Alarm Report Center Arming Disarming Report Center 73 1 0 74 1 0 Operation Warning Tone 75 1 0 Emergency Alarm Siren User Code Start Wireless Transmission Recover Factory Settings New command for wireless 888843 XX siren encrypt command for message alert 8888771 turn on upon system arm and 8888770 turn off disarm setting Modify command of delay 888844 XX NEM Modify command of delay 888845 XX alarm to can shut down the voice 88887814 turn on FEES FCR
4. gt 0 gt 4 Manual Recording Under the setting state input the address code 701 and press the 4 key to confirm After the main device makes a sound of the signal lamp flashes once the System starts to count down from 10s and the recording starts please keep close to the main device within 30 cm and say your message after 10s the main device gives a sound of Beep and the recording ends Setting steps 701 gt 4 SOS Siren on Remote Controller Under the setting state input the address code 76 by the keypad of the main device select the 0 1 key to turn off on the external siren for SOS alarm and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of Successfully set By default the siren is off when sending SOS alarm from the remote controller Warning Tone for Arming Operation Under the setting state input the address code 75 select the 0 1 key to turn off on the external siren when conducting the operations of arming disarming and press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully set If you turn on the warning tone the main device will sound once on arming and twice on disarming It is convenient for users to make sure if the arming disarming setting is successful when using the remote control Enabling Landline Phone Under the setting stat
5. the main device should be installed in the center of the zone Note that the main device should be installed away from large metal objects or household appliances with high frequency interference as well as barriers like reinforced concrete walls and fireproof doors etc Panel Diagrammatic Sketch Power power indicator lamp SET setting status indicator lamps ARM away arming lamps 16 08 Power OARM Alarm OSET Home Signal Home home arming lamps Alarm alarm lamps Signal signal lamps Delete Key Press the key to clear input errors if no digit is input it will make a warning tone Back Diagrammatic Sketch SP 12V TEL LINE OOOOOO H SIM card Sockets SP Alarm Siren 12 Power Adapter TEL Telephone LINE Exterior Line GSM SECURITY ALARM SYSTEM Connection Ports SPK and SPK External Intercom Speaker Z1 Z2 Wired zone short circuit alarm the Alarm will display zone 98 99 GND Ground wire 12V Power output of wired zones LCD Display Dialing Indicato Zone Type Fire Emergency Gas Leak Living room Window Balcony Gate Lock Perimeter Function Setting Initialization Install the SIM card to the main device and connect the adapter to the main device After the LED lamp stays on and the icons on the LCD display for 2 seconds the main device will gives a long beep and then go into initialization After the S
6. 2 New command for wireless siren encrypt 888843 XX 3 Pole connector ANT is designed for external GSM antenna AND is for _ earth grounding GSM SECURITY ALARM SYSTEM Maintenance System Inspection To make sure that the System runs steadily reliably and safely regular maintenance and detection are a must A full inspection to the main device should be conducted every 3 months and we suggest that the detector get an inspection monthly or every 3 month at least Inspecting the main device 1 Check whether it can arm or disarm normally 2 Check whether it can make calls when alarming 3 Check whether it can receive signals from detectors and whether the backup battery is normal Inspecting the detectors l Check whether the detectors can give a normal alarm by manually triggering them 2 Check whether all detectors to prevent low battery 3 Check whether all wireless detectors can communicate with the main device by testing the transmission condition Precautions Don t dismantle repair or rebuild the product on your own or else accidents or troubles may occur Protect the product from falling or impact to the floor or hard objects or else fault or damage may occur due to intensive impact Don t set 110 119 or the number of the police station as the alarm report telephone without permission of related departments Technical Parameters Attached List 1 JmputV
7. gt A gt 41 A stands for the serial number of the remote controllers 1 8 Deleting Remote Controller After the remote controller is deleted it cannot control the main device any more Under the setting state input the address code 21 and press the serial number of the remote controller with 178 and then press the 4 key to confirm After the main device gives a long beep and the signal lamp flashes once the System will give a voice prompt of Successfully Deleted The deleted remote controller will be out of work Setting steps 21 gt A gt 4 A stands for the serial number of the remoter controllers 1 8 Code Pairing for Zones Code pairing shall be performed between the wireless detectors and zones to trigger alarm on the main device Under the setting state input the address code 23 and press the serial number of zone within 01 99 and then press the key to confirm After the main device gives a long beep the LCD screen displays the corresponding zone and the System will give a voice prompt of Send codes by detector trigger the detector you desire to match code after the main device receives the signal it will gives a long beep then the System will give a voice prompt of Code pairing succeeded Setting steps 23 gt xx gt 4 XX stands for the serial number of the zone 01 99 Deleting Zones After a zone is deleted it cannot trigger alarm on the main device an
8. 5 USER MANUAL ELLEN 5 ecurit y ALARM SYSTEM Preface Thank you for purchasing our GSM Security Alarm System The System The System will keep your home and property safe around the clock The GSM Security Alarm The Alarm adopts the most advanced Israeli digital security technology with a high reliability and low false alarm rate it has a simple design but powerful functions such as fire prevention burglary prevention gas leak prevention housebreaking prevention SOS for emergent diseases etc Meanwhile you can also equip wired or wireless detectors which feature functions like anti interference false alarm prevention missing alarm prevention user friendly operations etc It is widely used for networking alarm in houses shops convenience Stores accounting offices villas residence communities and cities For your safety and giving full play to the functions of the Alarm please read the user manual carefully before installation and operation if you have any trouble during installing or operating please contact with local dealers or authorized technology service centers for help You can also call us to solve troubles by our professional technical engineers Note To get the complete after sale service of Three Guarantees please don t remove the Alarm cover to repair or rebuild by yourself in such cases the warranty will be void and we shall not be liable for any damage a
9. EM Answering Call Alarm After the main device gives an alarm it makes a warning tone at once and auto dials the first preset mobile phone to make a voice alarm If nobody answers the phone call the main device will auto dial the next preset phone number and repeat the above process It will call the 3 preset numbers circularly for 3 rounds with three calls for each preset phone If you answer the phone the alarm recording will be delivered At the moment you can activate different functions by your phone keypad Hang up the main device will conduct the same operations as the situation of no answer Press key you can read the alarm SMS message Press the 1 key the main device will stop the alarm stay arming and stop dialing Press the 2 key the main device will stop the alarm stay in disarming and stop dialing _ Press the 3 key the main device will turn off the warning ring and enter listen in state for 30s if you need to extend the listen in time press the 3 key again You can check whether there is abnormal noise or any invader at your home Press the 4 key start the spot intercom function for 30s Remote Control Dial the phone number bound with the main device by your cell phone after the preset ringtone times you will hear the warning tone of Please input your password At the moment input your password if the password is correct and you will hear the voice prompt of Pr
10. bers The main device can send text alarm to 3 preset phone numbers With 10 second manual recording function to leave messages With a built in digital voice device to give voice alarm automatically With built in SMS service to send alarm messages automatically Supports wireless alarm siren and control by wireless devices customization With the One Key Control function you can conduct Away Arming Home Arming Remote Control Arming or Off site Telephone Arming Alarm Location Programming Help Fire Gas Leak Door Lock Living Room Window Balcony and Perimeter Alarm Includes multiple zone programming functions like Real Time Delay 24 Hour Bypass With Wireless Self learning Code Pairing new accessories can be installed conveniently safely and effectively Off site remote control allows Main Device Arming Disarming Monitoring Intercom etc Arming Modes Remote Control Real Time Arming Away Delayed Arming Home Stay Arming Timing Arming Off site Telephone Remote Arming H Line Seizure If an alarm happens the main device will cut off the busy line and give priority to make a call for the alarm With a built in 7 2V lithium battery it can power the Alarm during a blackout Comply with the CCC Safety Standard and GB12663 2001 national standard W Compatible ADEMCO Contact ID protocol customization Introduction to the Main device To better receive the signals from all wireless detectors
11. e input the address code 71 select the 0 1 key to turn off on the landline phone alarm on the main device and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of GSM SECURITY ALARM SYSTEM Successfully set By default only GSM Alarm is enabled If you turn on the Landline Phone Alarm the main device will make an alarm by both ways offering higher grade of security Ringtone Times for Landline Phone Alarm Under the setting state input the address code 72 press a key within 1 9 to select the ringtone times and press the y to confirm This setting is only used for the landline phones Wireless Signal Output from the Main Device Under the setting state input the address code 41 select the 0 1 key to turn off on the wireless signal output from the main device and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of Successfully set If you turn on this option the main device will send out different wireless signals according to the following conditions You need to customize the hardware before setting this function 1 Alarming 2 Disarming 3 Pressing the below key combinations on the keypad of the main device 0 0 1 19 2 2 3 3 4 48 5 Si 6 GM 7 TH 8 8 4 If you want to get wireless signal output from the main device when conducting operations like SMS Control Remot
12. e Control you need to customize the software 5 The wireless signal is set to 315MHz 4 7MQ by default If you want to use other frequency or speed rate you need to customize it Networking Center Settings networking functions customized 1 Arming Disarming Report Center Under the setting state input the address code 74 by the keypad of the main device select the 0 1 key to turn Arming Disarming Report Center and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of Successfully set This function is set to OFF by default 2 Alarm Report Center Under the setting state input the address code 73 by the keypad ofthe main device select the 0 1 key to turn off on Alarm Report Center and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of Successfully set This function is set to OFF by default 3 User Code Under the setting state input the address code 74 by the keypad of the main device and input a 4 digit user code and press the key to confirm After the speaker gives a long beep the System will give a voice prompt of Successfully set 4 Networking Center Phone Number Under the setting state input the address code 50 by the keypad of the main device and input a phone number XX XX with 22 digits at most and then press the key to confirm After the speaker g
13. ess 1 for arming 2 for disarming 3 for listen in and 4 for intercom if incorrect you will hear the warning tone of your password is wrong pleas enter it again In this function you can conduct remote control operations through the cell phone keypad Press the 1 key the main device will enter the arming state and you will hear the warning tone of The System is on arming from the handset Press the 2 key the main device will enter the disarming state and you will hear the warning tone of The System is on disarming from the handset Press the 3 key the main device will enter the 30s listen in state to extend the listen in time you can press the 3 key again to get another 30s for listen in Press the 4 key start the intercom function for 30s SOS Sometimes you need to make an emergency call e g 110 for help such as when the old or children struck by a sudden illness a fire occurs robbers intrude into your home In such cases you just need to press the 9 key on the main device or the 2 key on remote controller The System will give an alarm at once and make emergency calls automatically Operation by the remote controller press the D key once Operation by the main device press the i9 key Wireless control 1 Activate the wireless control function and set the console at disarming status Input command 1 to turn on the home automation apparatus signal and 1 to turn off the signal
14. iming Disarming Under the setting state input the address code 36 38 and press the hour AA and the minute BB of the auto disarming time and then press the key to confirm after the main device gives a long beep the System will give a voice prompt of Successfully set Setting steps XX gt AA gt BB gt XX stands for the address code of 3 groups of timing auto disarming 36 37 and 38 AA stands for the hour of the auto disarming BB stands for the minute of the auto disarming Example the auto disarming time is 7 55am per day Setting steps 36 gt 07 gt 55 gt 3 Timing On Off Under the setting state input the address code 39 and select the 1 0 key to tum GSM SECURITY ALARM SYSTEM On Off the timing arming disarming function and then press the 8 key to confirm after the main device gives a long beep the System will give a voice prompt of Successfully set It is set to ON by default Setting steps 39 gt 01 gt 4 0 stands for turning off all timing arming amp disarming functions 1 stands for turning on all timing arming amp disarming functions Example turn on the settings ofthe timing arming amp disarming functions Setting steps 39 gt 1 gt 4 Alarm Telephone Setting Under the setting state input the address code 51 56 and enter a cell phone landline phone number and then press the key to confirm After the mai
15. ives a long beep the System will give a voice prompt of Successfully set GSM SECURITY ALARM SYSTEM Main Device Status The main device has four statuses in the normal conditions Arming Status The zones 1 99 can give alarms Home Arming Only the zones set as Home Arming are effective and can give alarms Disarming Status The zones 1 99 cannot give any alarm 24h zones not included Setting Status All zones don t give any alarm when the main device is in setting status Power failure Status If the System is on the arming status it will send out a short message upon power failure and the LCD screen displays in the low battery mode Daily Operations Users can use the remote controller to conduct operations such as Away Arming Home Arming Emergency Alarm or Real Time Disarming etc to the main device from outdoors or over a long distance Away Arming press the key to enter the Away Arming status Disarming press the LN key to enter the Disarming status Home Arming press the 7 key to enter the Home Arming status Emergency Alarm press the key to trigger the main device immediately and give an emergency alarm Away Arming When you re away it s necessary to use the Away Arming function Under this status all detectors are activated to arming If any source like an invader fire gas leak etc triggers the detectors the System will give an alarm at once
16. n device gives a long beep and the signal lamp flashes once the System will give a voice prompt of Successfully set Setting steps XX gt YY YY gt 4 XX stands for the address codes for 1 6 groups of alarm receiving phone 51 56 stands for the set telephone number Example set the 13811111111 as the first group of alarm telephone Setting steps 51 gt 13811111111 gt Deleting Alarm Receiving Telephones Under the setting state input the address code 51 56 and press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully set and the signal lamp flashes once indicating the telephone number has been deleted Setting steps XX gt XX stands for the address codes of 1 6 group of alarm telephones 51 56 Example delete the third group of telephone number from the main device Setting steps 53 gt SMS Receiving Phone Setting If phones are set to receive text alarm the System only sends an alarm message to the 3 groups of cell phones for example zone 5 balcony alarm Under the setting state input the address code 57 59 and input the cell phone number and then press the 4 key to confirm After the main device gives long beep the System will give a voice prompt of Successfully set and the signal lamp flashes indicating the SMS receiving phone numbe
17. nd negative results Please keep the user manual for reference in the future GSM SECURITY ALARM SYSTEM CONTENTS Introduction to Functions eere nnne enne nennen Introduction to the Main device cssssssssssssssessssscsneecseesseesstessussssvessnecsnecnsnensneesnees Function Setting eese eene tnnt ennt nennen Initialization T RN Exiting from Setting Recovering the default password eene Recovering factory settings eene nennen Code Pairing for Remote Controller eene Deleting Remote Controller ree Code Pairing for Zones nnne Deleting Zones tenente tenente nente tenen tntentnn ennt Changing Password tentent nennen Clock Setting Timing Setting esent Alarm Telephone Setting ener Deleting Alarm Receiving Telephones SMS Receiving Phone Setting essen Deleting SMS Receiving Phones sssssssssseeseessesseseeessssessesseeseeneenennennenneneenss Zone Programming esent nnne nnne nennen Home Arming Setting Manual Recording eene SOS Siren on Remote Controller M Warning Tone for Arming Operation
18. olage DCDV ASA Standby Current A 55A Wireless Frequency 315MHz 2262 4 7MQ GSM System Quad Band 850 900 1800 Backup Battery 7 2V lithium battery Alarm Siren Volume 10dB GSM SECURITY ALARM SYSTEM Attached List 2 Wer Effective Real Tine Doir lak Qi Zone1 Effective RealTime Door Lock On Effective Real Time Living room On Zoned Effective Real Time Balcony _ On RealTime Geek On Wired Zo 98 99 GSM On Phone Line Off Optional Instruction Set All instructions should be ended with Learning Remote Recover Controller ama Password Deleting Remote Controller Learning Zone 2310199 Deleting Zone 2300199 LGNXXIAIIBIIC Zone Programming 60 XX A B C Home Stay Arming Setting Telephone Number of Networking Center DeletingTelephone Number of Networking Center Setting Telephone Number DeletingTelephone Number SE Setting SMS receiving Telephone Number Deleting SMS receiving 57 91 Telephone Number Change User Password 30 XXXX ChangeEngineerin 31 XXXX Password System Time 32 Hour Minute Timing Arming 33 5 Hour Minute Timing Disarming 36 8 Hour Minute Timing On Off 39 1 0 Recording 701 GSM SECURITY ALARM SYSTEM Enable Telephone Line 71 1 0
19. onding zone 01 99 B stands f r the zone type including 1 Real Time 2 40s Delay 3 24h 4 Bypass C stands for the installation location including 1 Help Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Lock Alarm 5 Living Room Alarm 6 Window Alarm 7 Balcony Alarm 8 Perimeter Alarm D stands for the alarm type including 0 Alarm without warning siren 1 Alarm with warning siren Example set the alarm type for the Zone 12 as 24h Fire Alarm and Alarm with Warning Siren Setting steps 60 gt 121 gt 31 gt 2 gt 11 gt 4 Home Arming Setting By the Home Arming Setting function you can set the working status for detectors separately Just conduct some settings for the home arming zones Under the setting state input the address code 61 select the serial number of the corresponding zone 01 99 and select the 0 1 key to turn on off the alarm and then press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully set Setting steps 61 gt Xx gt A gt 21 XX stands for the serial number of the corresponding zone 01 99 A stands for the alarm status including 0 Home Arming without Alarm 1 Home Arming with Alarm Example set the Zone 11 as Home Arming with Alarm Setting steps 61 gt 11 gt 11 gt 4 Example set the Zone 12 as Home Arming without Alarm Setting steps 61 gt 12
20. r has been set Setting steps XX gt YY YY gt 4 XX stands for the address codes of the 1 3 group of SMS phone 57 59 YY YY stands for the set telephone number Example set the 13822222222 as the first group of SMS phone Setting steps 57 gt 1382222222 gt Deleting SMS Receiving Phones Under the setting state input the address code 57 59 and press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully deleted and the signal lamp flashes once indicating the phone number has been deleted Setting steps XX gt XX stands for the address codes of the 1 3 group of SMS receiving phone 57 59 Example delete the first group of SMS phone from the main device Setting steps 57 gt 4 Zone Programming By the Zone Programming you can change the attributes of the zone alarm such as turning off the warning siren etc Under the setting state input the address code 60 enter the serial number of the zones 01 99 press the zone type 1 4 and press GSM SECURITY ALARM SYSTEM the zone location 1 8 and select 0 1 to turn on off the warning siren and then press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully set Setting steps 60 gt AA gt B gt C gt D gt AA stands for the serial number of the corresp
21. then set a new password for the main device Under the disarming state input 95175308249 and press the key to confirm after the SET indicator lamp stays on for 2 seconds and the main device gives a long beep the ex factory password is recovered whereas all settings remain the same Setting steps 95175308249 gt GSM SECURITY ALARM SYSTEM Recovering factory settings If the System works unsteadily or you have forgotten the previous setting parameters we suggest you recover the factory settings and set new parameters for the main device Under the disarming state input 95175308246 and press the key to confirm after the LED indicator lamps stay on for 2 seconds and the main device gives a long beep the factory settings is recovered with all user settings cleared Setting steps 95175308246 gt 4 Code Pairing for Remote Controller Code pairing shall be performed before the remote controller is used to control the main device Under the setting state input th address code 20 and press the serial number of the remote controller with 178 keys and then press the key to confirm at this time the main device gives a long beep and gives a voice prompt of Send codes by remote controller press a key on the remote controller to send a wireless signal after receiving the signal the main device will gives a long beep and give a voice prompt of Code pairing succeeded Setting steps 20
22. word has been changed Setting steps 31 gt XXXX gt XXXX stands for the new four digit password Example Change the password to 2846 Setting steps 31 gt 2846 gt Notes The engineering password cannot be the same as the user password Clock Setting Under the setting state input the address code 32 and input digits of the current hour in 24 hour system AA and the minute BB and then press the key to confirm After the main device gives a long beep the System will give a voice prompt of Successfully set Setting steps 32 gt AA gt BB gt 7 AA stands for the digits of hour of current time in 24 hour system BB stands for the digits of minute of current time Example the current time is 3 35 PM Setting steps 32 gt 15 35 gt Timing Setting 1 Timing Arming Under the setting state input the address code 33 35 and input hour AA and minute BB of the auto arming time and then press the 4 key to confirm after the main device gives a long beep the System will give a voice prompt of Successfully set Setting steps XX gt AA gt BB XX stands for the address code of 3 groups of timing auto arming 33 34 and 35 AA stands for the hour of the auto arming time BB stands for the minute of the auto arming time Example the auto arming time is 10 45 PM every day Setting steps 33 gt 22 gt 45 gt 4 2 T
23. y more Under the setting state input the address code 24 and press the serial number of the zone you want to delete within 01 99 and then press the key to confirm After the main device gives a long beep the serial number of the corresponding zone flashes once on the LCD and the System will give a voice prompt of Successfully deleted The deleted zone cannot trigger alarm any more Setting steps 24 gt xx gt 4 XX stands for the serial numbers ofthe zone 01 99 Changing Password 1 User Password The user password is the key to access the System when disarming or conducting operations by the remote controller GSM SECURITY ALARM SYSTEM Under the setting state input the address code 30 and input a four digit password and then press the key to confirm after the main device gives a long beep the System will give a voice prompt of Successfully set then the previous password has been changed Setting steps 30 gt xxxx gt XXXX stands for the new four digit password Example Change the password to 1012 Setting steps 30 gt 1012 gt 2 Engineering Password The engineering password is the key to access function settings Under the setting state input the address code 31 and input a four digit password and then press the key to confirm after the main device gives a long beep the System will give a voice prompt of Successfully set then the previous pass
24. ystem displays the correct time it starts to detect the GSM network until a normal network is obtained then the main device gives a long beep and the signal strength will be displayed a signal strength of at least 2 bars is required then the main device is in the state of disarming Finally turn the switch of the backup battery to ON Setting Under the disarming state input a four digit password XXXX and press the key to confirm When the main device makes a voice prompt Please input commands while the SET lamp stays on and the LCD displays Reset it indicates that the System is on the setting state In this state you can conduct various function settings If you don t conduct any operation on the keypad for over 40 seconds the main device will auto exit from the setting state and return to the disarming state Notes Under the setting state press the key to delete the input numbers Setting steps XXXX gt X stands for a digit of the four digit password with the ex factory value of 8888 Exiting from Setting After completing the settings press the key and key on the keypad until you hear the sound of Beep the System exits from the setting state At this time the SET lamp goes off and the System returns to the disarming state Setting steps gt 4 Recovering the default password If you forget the password we suggest you recover the ex factory password and
Download Pdf Manuals
Related Search
Related Contents
Télécharger le supplément Illetrisme : PDF FORGE CRACK & JOINT FILLER User Manual - Cooper Industries Manual del usuario WP-Manager SmartControl, 1, de_DE PYLE Audio PADH1549 User's Manual HP Memory Modules User's Manual Ricoh TLS 401 Operating Instructions GA-8I915P Duo (Pro) Edge10 4TB DAS801t Copyright © All rights reserved.