1. Master or Alone The selection Alone means Stand Alone mode and Master that the device is defined as master Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu 3 Program selection for Auto Pro Part Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter button to confirm e Turn the encoder to select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and thus select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu 4 Program selection for Edit Program Select Edit program by turning the encoder Press the Enter button to confirm Select Edit program by turning the encoder Press the Enter button to confirm Turn the encoder to select the desired program With this function you can edit specific scenes into a specific program Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu 5 Automatic Scene Recording Select Edit program by turning the encoder Press the Enter button to confirm Select Edit scenes by turning the encoder e Turn the encoder to select the desired
2. RIBALTA en ene sO l lt D Z lt gt 0 na W Vv Thank you for your patronage We are confident that our excellent products and service can satisfy you In order to install operate and maintain the lighting safety and correctly we suggest to have verified technicians to install the item and to strictly follow the instructions INTRODUCTIONS Thank you for choosing the professional led color changer You will see you have purchased a powerful and versatile device Unpack the device The package contains 1 One XLR waterproof connection cable 2 One waterproof power cable 3 One safety rope 4 Manual Below are the optional accessories that can be purchased from your local dealer 1 Remote Controller Please carefully check that the package is intact after transportation Should there be any damage consult with your dealer and don t install the device Features e Equipped with 30 LEDS 10 x 3W red 10 x 3W green 10 x 3W blue e 100 000 hours LED life e DMX Channel modes 8 DMX channels selectable for several applications e 1 18 flashes per second strobe effect e General dimming and blackout for all three effect Excellent RGB mixing and rainbow effect Friendly blue and white LCD display Dimmer 0 100 linear dimming e Software upload by optional accessory via DMX line OVERVIEW Lee gt 6 Enter button 1 LED 2 LCD Display 7 IR 3
3. in good condition and extend their life time we suggest a regular cleaning 1 Clean the inside and outside lens every week to avoid the lights weaknesses due to the dust accumulation 2 Clean the fan every week 3 A detailed electric check by approved electrical engineer every three months make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the lamp Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine parts from your local dealer TECHNICAL SPECIFICATIONS Power supply AC 100 240V 50 Hz 60Hz Power consumption 270W Waterproof grade IP 65 Net weight 16 5 KGS Gross weight 20 5KGS Remarks errors and omissions for every information given in this manual excepted All information is subject to change without prior notice
4. power on 1 Tap the MENU button until Manual Hold is displayed then tap the ENTER button 2 Press the UP button and select ON to activate this function or OFF to deactivate this function Press ENTER to confirm 3 Press MENU c to return to the main menu Reset Default With this function you can select restore factory set for ON or OFF the default is OFF Effect Adjust Manual Control This function is used to adjust the LEDS more easily All effects will be erased the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the light on a flat surface wall and reform the fine LEDS adjustment White balance White balance setting 1 Set Color_Mode at 220 2 Adjust red green and blue leds to achieve target white balance 3 Set Internal programs at 71 4 Set Color_Mode at 255 wait 4 seconds for the target white balance to be stored Edit program Select program With this function you can select the program for the Program Run Edit program With this function you can edit the internal programs Edit scenes With this function you can edit the scenes of the internal programs Auto scenes rec The moving head features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your contro
5. the timer password The time password is 038 Clear Last Run With this function you can clear the fixture last run time The display shows ON or OFF Press Enter to confirm Temp Info Head Temp With this function you can display the temperature on the base display board near CMY filter in Celsius Software version With this function you can display the device software version e Select Software version by turning the encoder Press the encoder the display shows V X X X X stands for the version number e g V 1 0 V 2 6 e Turn the encoder to read the version of every individual IC Press the Mode Esc button in order to return to the main menu PERSONALITY Status Settings Address via DMX With this function you can adjust the desired DMX address via external controller Select Address via DMX by turning the encoder Press the encoder the display shows ON or OFF Turn the encoder to select ON if you wish to enable this function or OFF if you don t Press the encoder to confirm Press the Mode Esc button in order to return to the main menu e On the controller set the DMX value of channel 1 to 7 Set the DMX value of channel 2 to 7 or 8 When set to 7 you can adjust the starting address between 1 and 255 When set to 8 you can adjust the starting address between 256 and 511 Set the DMX value of channel 3 to th
6. Mode esc button 8 Power input 4 Up button 9 DMX input 10 DMX output 5 Down button User manual of telecontrol BLACKOUT SELECTPROG SOUNDACTIVE ALON MAST SETADDR fixture that is to be changed A003 BLACK OUT The lamp will be turned off after having pressed the button and exit to the status of Address Display Press BLACK OUT 0 to reset to the initial status of infrared setting except address AUTO RUN Press this button to enter the built in rogram ge ACTIVE Press this button to enter the sound active it depends on whether this function exists in the lighting fixture O Every lighting fixture which receives the infrared signal changes it s addresses at the same time if not pressing this button when setting the address Choose what fixture is to be changed first then press this button to change the address Press it again to the start condition For example there are three lighting fixtures whose addresses are A001 A003 and A007 If the three fixtures receive the infrared signal the address will be changed if the MODE button is not pressed If you want to change the address manually you have to press the MODE button then choose one of the etc press SA button to change the address A010 etc This fixture address will be changed to A010 ALON MAST Press this button to the master slave mode SET ADDR Press this button NUMBER ENTER to set the a
7. al program 2 71 Store Color_mode enable 72 100 Internal program 3 101 130 Internal program 4 131 160 Internal program 5 161 190 Internal program 6 191 220 Internal program 7 221 255 Internal program 8 Color Mode 0 63 White balance disabled 8 64 189 White balance enabled 190 250 White balance disabled 251 255 Store a new white balance White balance setting 1 Set Color_Mode at 220 2 Adjust red green and blue leds to achieve target white balance 3 Set Internal programs at 71 4 Set Color_Mode at 255 wait for 4 seconds the target white balance will be stored CLEANING AND MAINTENANCE The following points have to be considered during the inspection 1 All the screws for installing the device or parts of it have to be tightly connected and must not be corroded 2 There must not be any deformations in the housing color lenses fixation and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any trace of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be given by a skilled installer and any safety problems have to be solved CAUTION Disconnect from mains before starting maintenance operation In order to have the lights
8. ddress ENTER press this button to confirm Under different function press the numbers and ENTER to change the address or the dimming Q this button for the red color full brightness Press number ENTER to dim the red color press again the red color will die out Q press this button to the green color full brightness press number ENTER to dim the green color press amp again the green color will die out press this button to the blue color full brightness press number ENTER to dim the blue color press again the blue color will die out W press this button to the white color full brightness press number ENTER to dim the W white color press again the white color will die out it depends on whether this function exists in the lighting fixture Q this button to the full amber color brightness press number ENTER to dim the white color press again the amber color will die out it depends on whether this function exists in the lighting fixture Notice press the buttons of the colors you want to mix NUMBER button or UP DOWN ENTER to mix the colors press this button to increase the value o press this button to decrease the value SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can Suffer a dangerous electric shock when touching wires This device has left the factory in perfect condition In order to keep this condi
9. ddress via the Control Board e Select Set DMX address via encoder Press the encoder adjust the DMX address by turning the encoder Press the encoder to confirm Press the Mode Esc button in order return to the main menu Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel The display automatically shows the channel with a value changing Slave setting With this function you can define the device as slave Auto Program With this function you can run the internal program You can select the desired program under Select program You can set the number of steps under Edit program You can edit the individual scenes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time Information Time information Current Time With this function you can display the device temporary running time from the last power on The display shows X XXX XX XX stands for the number of hours The counter is reset after turning the device off Total life Hours With this function you can display the device running time The display shows XXXX XXXX stands for the number of hours Last Run Hours With this function you can display the lamp last running time The display shows XXXX XXXX stands for the number of hours Time Password With this function you can display
10. e approved by a skilled technician once a year Cautions The effect should be installed outside areas where people may reach it walking by or being seated next to it Overhead mounting requires an extensive experience including amongst others calculating working load limits installation material used and periodic safety inspection of the whole installation material and device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury CAUTION The electric connection must only be carried out by a qualified electrician Before mounting make sure that the installation area can hold a minimum point load of 10 times the device s weight Connect the fixture to the mains with the power plug Clamp installation method Please refer to the picture below Fix the clamp to the bracket by tightening the M12 screw up on it to the 13 hole which is in the middle of the bracket Pass the safety rope through the connecting hole located under the side panel hanging on the fixed bracket or the other fixed station it can also be floor mounted or on any other flat surface without any fixing remaining steady no matter what the angle of the head is Fully operational in any mounting position hanging upside down side mounted or set on a flat level surface etc When clamp mounting always use and install the supplied safety cable as an added safety measure to prevent any acc
11. e desired starting address If you want to set the starting address to 57 set channel 1 to 7 channel 2 to 7 and channel 3 to 57 If you want to set the starting address to 420 set channel 1 to 7 channel 2 to 8 and channel 3 to 164 256 164 420 e Wait for approx 20 seconds and the unit will carry out a reset After that the new starting address is set No DMX Status With this function when the drive is not DMX signal it runs automatism close hold and music the default is hold Display Setting Shut off time With this function you can shut off the LCD display after 2 to 59 minutes Turn the encoder in order to select the desired shut off time Locked keys the display With this function you can activate the automatic key lock function If this function is activated the keys will be automatically locked after exiting the edit mode for 15 seconds Keep the Mode Esc key pressed for 3seconds if you want to deactivate the key lock status 1 Tap the UP button until KEY LOCK is displayed then tap the ENTER button 2 Press the UP button to select ON to activate this function or OFF to deactivate this function Press ENTER to confirm 3 Press Mode Esc to return to the main menu Temperature C F With this function display the temperature in Celsius or Fahrenheit Manual Hold With this function activated the fixture will return to the scene manual set automatically after the re
12. eat radiation If the external flexible cable or cord of this luminance is damaged it shall be replaced only by the manufacturer or his service agent or an as well qualified person in order to avoid a hazard CAUTION AN Never touch the device during operation The housing may heat up CAUTION N Never look directly into the light source as sensitive persons may suffer an epileptic shock Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals GENERAL GUIDELINES This device is a lighting effect for professional use on stages in discotheques theaters etc This fixture can be operated with the max alternating current which is stated in the technical specifications in the last page of this manual the device was designed for indoor and outdoor use The lighting effects are not designed for permanent operations Consistent operational breaks may ensure that the device will properly function for a long time Do not shake the device Avoid brute force when installing or operating the device The device shall only be used together with its protective shield While choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust The minimum distance between the projector light output and the illuminated surface must be more than 0 1 meter Operate the device only after having familiariz
13. ed with its functions Do not allow operations by not qualified persons to operate the device Most damages are the result of unprofessional operations Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the device are forbidden If this device will be operated in any way different from what is described in this manual the item may be damaged and the guarantee becomes void Furthermore any other operation may lead to short circuits burns electric shocks lamp explosions crashes etc INSTALLATION INSTRUCTIONS Mounting the device CAUTION Please consider the EN 60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a qualified person The applicable temperature for the lighting is between 25 C 45 C Do not use the lighting under or above the temperature The installation of the effect has to be built and constructed in order to hold 10 times its weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate safety rope Never stand directly below the device when mounting removing or servicing the fixture The operator has to make sure that the safety relating and machine technical installations have been approved by an expert before operating the device the first time These installations have to b
14. he channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You can set the same starting address for all fixtures or a group of fixtures or have different addresses for each fixture individually If you set the same address all the units will start to listen to the same signal control from the same channel number In other words changing the settings of one channel will affect all the fixtures at the same time If you set a different address each unit will start to listen to the channel number you have set based on the quantity of control channels of the unit This means that changing the settings of one channel will affect only the selected fixture In the case of the moving head which is a 8 channel fixture you should set the starting address of the first unit to 1 the second unit to 9 8 1 the third to 17 8 9 and so on Controller Control Board Set Dmx Address A001 AXXX DMX address setting Value Display PAN DMX value display 2 Set To Slave Slavel Slave2 Slave3 Slave setting Auto Program Master Alone Auto program Time Current Time XXXX Hours Power on running time Information Total Life Hours XXXX Hours Fixture r
15. idental damage in the event of the clamp failure Make sure that this fixture is kept at least at 0 1m away from any flammable material such as decoration etc DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain the multiple moving head together through a serial linking The needed cable should be a two core screened cable with XLR input and output connectors Please refer to the diagram below DMX Output DMX Input 5 Pin XLR Socket 5 Pin XLR Socket 1 Ground 2 Signal 3 Signal 4 N A 5 N A DMX controller Address 1 Address 9 Address17 DMX 512 connection with DMX terminator Thought for installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below PIN 3 PIN 2 Projector DMX start address selection All fixtures should be given a DMX starting address when using a DMX signal so that the correct fixture responds to the correct signals control This digital starting address is t
16. ller they will automatically be transmitted to the moving head Excursion A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start a Auto Program please proceed as follows 1 Slave Setting Select Function Mode by turning the encoder Press the Enter button to confirm Select Set to slave by turning the encoder Press the Enter button to confirm e Turn the encoder to select Slave 1 Slave 2 or Slave 3 Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu 2 Automatic Program Run Select Function Mode by turning the encoder Press the Enter button to confirm Select Auto Program by turning the encoder Press the Enter button to confirm e Turn the encoder to select
17. scene numbers You can program a maximum number of 250 scenes Turn the encoder to select the desired scene numbers You can program a maximum number of 250 scenes Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 16 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following P some seoan scese sconta 7 Part 2 same some ame ums H Part 3 INSTRUCTIONS ON USE DMX channel s functions and their values 8 Channel Value Function Shutter strobe 0 31 Led turn off 32 63 Led turn on 64 95 Strobe effect slow to fast 1 96 127 Led turn on 128 159 Pulse effect in sequences 160 191 Led turn on 192 223 Random strobe effect slow to fast 224 255 Led turn on j Dimmer intensity 0 255 Intensity 0 to 100 3 Red LED _ 0 255 Red 0 Black 255 100 Red 4 Green LED 0 255 Green 0 Black 255 100 Green 5 Blue LED 0 255 Blue 0 Black 255 100 Blue Color Correction 6 0 19 No function 20 255 20 2700K 255 7200K Internal programs 0 10 No function 7 11 40 Internal program 1 41 70 Intern
18. tion and ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual gt Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to sudden changes in temperature due to environmental changes do not switch it on immediately The arising condensation might damage the device Leave the device switched off until it has reached the room temperature This device falls under protection class I Therefore it is essential that the device is earthed The electric connection must be carried out by qualified personnel Don t move the device when is set in the operation mode Make sure that the available voltage is not higher than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges In this case the cable replacement must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Handle the power cord only by the plug Never pull out the plug by tugging the power cord Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep at more than 50cm distance from the wall for smooth air flow so there should be no shelter for the fans and the ventilation for h
19. unning time Last Run Hours XXXX Hours Fixture Last times clear Timer Password Password XXX Timer Password 038 Clear Last Run ON OFF Clear Fixture Last time Temperature Head Temperature XXX C F Temperature in the head Info Software Ver1 0 Software version of each Version IC Status Settings Address via DMX ON OFF Add via DMX No DMX Status Close Hold Auto Auto run if no DMX Display Shutoff Time 02 59m 05m Display shutoff time Setting Key Lock ON OFF Key Lock Temperature Celsius Temperature switch A C F Fahrenheit between C F Manual Hold ON OFF Keep mannual control Reset Default ON OFF Restore factory set _ Manual PAN PAN XXX Fine adjustment of the 5 Control gt led 5 lt 3 White Balance Red Red XXX White balance adjust m Select Auto Pro Part Program 1 10 Program 1 Select programs to be run Programs 1 Program 1 10 Program 2 Auto Pro Part Program 1 10 Program 3 2 Auto Pro Part 3 Edit Program Program 1 Program Test STEP XX Testing program Bb Step Program in loop Program 10 01 SCxxx Save and exit Step 5 D 64 SCxxx Edit Scenes Edit Scene Pan Tilt Pan xxx Save and automatically 001 Secne Time TIME xx xs return Edit Scene Input By manual scenes edit 250 Outside Rec XX XX Automat scenes rec Default settings shaded Function Mode DMX address setting With this function you can adjust the desired DMX a
Download Pdf Manuals
Related Search
Related Contents
Binatone Focus66 Microbiology Portfolio extended 大規模災害等緊急事態における通信確保の在り方に関する検討会 Myscouts.ca Report User's Guide – Membership Listing Eurofase 16482-012 Installation Guide Philips WAS6050/05 User's Manual Différentes aides en nature (bons alimentaires - ocmw-info-cpas RAPID User Manual Copyright © All rights reserved.