1. e y Pd amp Il ji ho MES L i II T Pe l T ee End airs y de i Mi Note Panel with hinge holes goes on the left side a N Install the front fixed glass panels Remove plastic clip in horizontal frame slide glass in place and reattach clip to hold glass into place Do the same for the right side s d FF aa 1 Connect the power to the fan light and speaker plugs The i SR E accessories are marked MN lo li FL 2 Align holes on the left right and back side with the holes on i pa ih Fm the left back and side panels k i Y 3 Install the ceiling with wood screws ST4X20 and cover with lg tm decorative cap tog ll 1 4 Using ST4X20 screw kits Screw brass washer decoration IH Ill I cap 1 i i Pp y vo la li gt CL gt I AA o sy Ay E i YN Y H i ETA 12 Install the hinges on the left side glass then attach door to a e hinges PLL pd ko ija 5 Attach hoses to rainfall showerhead and connect the right Nata side body jets with the hoses provided 13 Install the door handle adjustable handheld shower bar if 6 Reinstall the aluminum trim on side panels not done in previous steps l 7 Page Rev 9 2012 INSTALL THE GASKETS i AAC MEA P a ee o Lf E a E m i Po Ee ee e 1 Once allis co
2. has 4 C variance between accrual set temperature and real temperature The default steam setting is 45 C if the user does not choose any setting ee ER Time Setting Touch the Steam Time Setting button and the display The range is 20 59 minutes Let go of the button when the figure reaches the desired time and is set as the working time for the system The system is automatically shuts off when the set time expires or 45 minutes is up default system time EJ Chromatherapy This button controls the color of the Chromatherapy LED lights picture 5 When the Chromatherapy function starts the lamp symbol on the LCD display flashes LD circulation Fan This button turns fan on off When fan Is turned on the fan symbol on the LCD display Flashes CIA on off This button turns the steam on off Touching this button makes the steam symbol on the LCD display flash The temperature sensor regulates steam output based on the preset steam temperature The steam generator has 4 C variance between accrual set temperature and real temperature uste on off This button turns music on off Co JEM Radio on off Touch this button and the radio station will show on the display The FM radio is now on The radio frequency by default is the same as the radio freguency selected last time Note if the MP 3 shows on the display the radio will not play Touch the FM radio button again Le volume amp Frequency Adjust e Volume Touch this bu
3. 32 Inch 2150mm 84 5 Inch 200V 60 50Hz 1500mm 59 Inch 915mm 36 Inch 2150mm 84 5 Inch 200V 60 50Hz 1500mm 59 Inch 1015mm 40 Inch 2150mm 84 5 Inch 3 Page Rev 9 2012 ELECTRICAL INFORMATION 1 dedicated 12 2 wire with 20 amp GFCI breaker 220V Connect the overhead light speaker fan CD telephone according to the tags on the wires Do not connect the wire 03 to anything Connect main power supply PLUMBING INFORMATION The unit is equipped with 3 ft hot and cold metal braided water supply hose with inch national pipe thread to connect from faucet manifold Manifold is located 4 ft high on rear of unit to the shutoff valves should be installed where they can be accessed Note base edge sets directly against back and sidewall Do not install any pipes along walls as to impede the base from setting flush against them Install hot and cold shutoffs with inch male national pipe thread not included Install shutoffs where they can be accessible Access panel near controls pumps and jets is recommended Drainage It is advised to have base onsite before preparing drain location The diameter of the drain hole should be larger or equal to 40mm 1 6 inches Note The flexible drain hose included with acrylic base is for installation into a floor drain only Substituting the this drain setup for a setup of the installers choice will not void the warranty of the unit as long as there is no evidence of misuse or
4. E FS Steam Temperature Sensor LCD Display Control Panel Water Diverter Water Flow Adjustment On 0 ff Water Temperature Adjustment Body ets Steam Qutlet Handheld Shower Set Steam Generator Cleaning Liquid Inlet LCD DISPLAY Fahrenheit Degree if applicable Celsius Degree Temperature Temperature Indicator Time Setting FM Radio Frequency FM Radio Volume FM Radio Channel Chromatherapy on off Circulation Fan on off Steam on off Power on Indicator FM Radio Frequency Mp3 on off JE O ili GG GE ES E la bi E ir 9 Page Rev 9 2012 CONTROL PANEL FOR STEAM SHOWER Power on off Steam temeprature setting Steam time setting Circulation Fan Chromatherapy Steam on off Music on off Radio EI Volume Freguency lei Radio memory t adjustment adjustment 10 Page Rev 9 2012 CONTROL PROCEDURES bi mer on off Push any button to light the display and press the power on off switch to start the system Push the power on off switch again to turn off the system and display Steam Temperature Setting Touch the Steam Temperature Setting button and the display will appear on the screen The temperature ranges from 20 C to 59 C circularly Let go of the button when the desired temperature has been reached and the figure is set as a steam setting The steam generator stops working when the temperature inside is 4 C higher than setting temperature The steam generator
5. d Use standard stone base installation to secure the base in place The drain hole is 3 inches in diameter The drain Is located in the center of the base The unit is assembled and sets entirely inside the stone base s water edge 33 37 41 inches _ 59 7 8 inches Height is 1 inch 5 Page Rev 9 2012 2 INSTALLATION INSTRUCTIONS FOR WS112 ALL SIZES I The distance between Wall A and Wall B should be at least 1510mm 59 5 inches The minimum height for the unit not including any base is 84 5 inches 1510 1530mm is lt lt Wall A Wall C WallB 1510 1530mm Eie e cc ce ee DOOR FRAME ASSEMBLY Note For California only Attach the door frame brackets with self tapping screws and expanding bolts 1 2 En E A EF 77 F 1 ay EJ A A S Bottom horizontal rail has wide opaque gasket top horizontal rail has grey gasket The 5inch side panel trim piece has to be removed to expose assembly screw holes Check on top and bottom horizontal rails the screw holes are tapped Note if they are not tapped tap before assembling To assemble front frame you will need at least 6 2 Philips bit It is advised to use an impact driver Do not over tighten Each 5 frame sidepieces has 2 grey rubber gaskets on top and bottom Bottom piece has to be all way down top piece all way to the top Assemble horizontal rails to wid
6. damage to the base If the substitute drain system is used a 3 8 in stub must be added to the main shower drain line to connect the steam generator s automatic flushing drainage hose All fixtures and fittings must be checked for tightness as they may have been loosened during transport PLUMBING REQUIREMENTS The unit is equipped with hot and cold metal braided water supply hoses with Y national pipe threaded fitting Need to install hot and cold shutoffs with male national pipe thread not included All fixtures and fittings must be checked for tightness as they may have been loosened during transport Note for Acrylic Base ONLY The flexible drain hose included with this unit is for installation into a floor drain only Substituting the existing drain setup for one of the installers choice will not void the warranty of the unit as long as there is no evidence of misuse or damage to the base GENERAL INFORMATION The main wall panel with water manifold and electrical equipment is designed to be installed on the left side of unit If water and electrical connections are on the right side these side wall panels are interchangeable please call Steam Planet Technician before this is done This must be completed onsite by installer Units come broken down in panels and are assembled with screws nuts and bolts on site All Acrylic shower bases need to be leveled in its final resting position all feet must be touching the ground mark the
7. e vertical rails with ST4X50 self tapping screws INSTALLING SHOWER WALLS Note It is advised to assemble to soap dish with M4X25 screws 2 screws 2 nuts 2 bolts 2 brass washers and 2 caps before putting any panels together Also attach the sliding bar for the handheld shower on the left side Hardware Is inside cloth bag l 2 3 4 Place large back panel on back side of base Remove trim piece from right side of left side glass panel This will expose the assembly screw holes Attach Power supply and water supply to the left side panel Attach left side panel to back panel using ST4X16 self tapping screws pre drilled holes should line up Attach right side panel in same fashion as previous step Attach the front glass frame that was assembled before using the ST4X16 self tapping screws Run the drain hose from the steam box through the small hole on the bottom center of the left side panel Hose should extend into shower room Will be covered by wood grids e 2 2 S RRA pge AN 2 o ae a 1 y gt to _ LA mmm i ya Seal unit to the acrylic base along the walls leaving the corners open Secure unitto base acrylic base do not drill stone base Attach all sides with tapping screws and blocks Apply silicone to seal the gap between panels and floor Leave the corners without silicone 6 Page Rev 9 2012
8. is button for power on off Push and release this button shortly to change between transmitting and clock Audio signal input to be connected to audio signal output interface of Mp3 player AV Transmitting frequency adjusting push this button to increase decrease for transmitting frequency for FM The adjusting range is 88 108 8MHz LO Transmitting channel memory push and hold this button to memorize this channel after the transmitting frequency is selected 1D Note Transmitting channel adjusting push this button to select the transmitting channel from memory up or down 1 Make sure not to select transmitting frequency which is the same as the existing FM radio frequency because it will not transmit 2 The wireless FM transmitter should be placed far away from any other wireless transmitting device 13 Page Rev 9 2012 TROUBLESHOOTING FOR STEAM CABIN 1 Not connected properly Check connection between control panel Touch panel does not work and power box 2 Wrong voltage Change to 220V supply Desired steam room temperature is Increase the desired temperature to be lower than current temperature higher than current temperature 1 2 The water inlet valve not letting water Check water inlet valve for blockage and 12V power supply to valve in 3 The water level sensor is not working Clean scale of the water level sensor or water coming out steam outlet replace it No steam 4 Thermal switch in the hea
9. nnected place the wooden shower grid floors and benches inside the unit 2 Please do not use the unit for at least 24hours or until the Silicone is completely dried CLEANING AND MAINTENANCE FOR ALL UNITS 1 Liquid detergents and soft cloth should be used Do not use any abrasive cleaners 2 The scale on the surface can be cleaned with a soft cloth and non abrasive cleaner or heated vinegar 3 After every 30 uses we suggest you to clean the steam generator We advise the use a filtration system for the steam generator unit One Compatible filtration system option is the Whirlpool WHKF DWHV STEAM GENERATOR CLEANING FOR ALL UNITS Remove the cover of the cleaning liquid inlet and pour in approximately 1L of citric acid or white vinegar Start the steam function to fill the steam generator with water Stop the steam function before the steam starts to come out acidic steam is damaging to plated fixtures Do not shut off the main power The scale in the steam generator dissolves and the system drains the dirty water out after 60 minutes GENERAL USE AND MAINTENANCE FOR ALL UNITS A Drops of water will continue to drain out from the jets and water outlets after use this is normal and it will eventually stop B Abrasive cleaners must not be used C Always shut off the power supply when the system is not in use 8 Page Rev 9 2012 CONTROL PARTS INFORMATION FOR STEAM SHOWER FOR ALL UNITS l 10 Po O B
10. one When calling for service questions please provide your model number serial number Purchase Order and type of problem you are having 2 Page Rev 9 2012 TOOLS REQUIRED FOR INSTALLATION Level Screw driver 2 Phillips CAS 7 Silicone Wrench e AP p rre OA Electric Drill CU 1511537 Square Ruler E Rubber mallet PRODUCT FEATURES DESCRIPTION 3kW Quick heating Self Draining Steam Generator Steam Aromatherapy Cup Body Massage J ets Hand held Shower w Various water massage settings amp adjustable height bracket 8 inch 203mm wide water drenching Rainfall Shower Thermostatic Anti scald Faucet Strengthened Black Back amp Side Tempered Glass walls Clear Glass Front amp Doors easily reversible 24inch 610mm Swinging Door Polished Aluminum Trim Glass Touch no seam Control Panel FM Radio Wireless transmitter for Radio Chromatherapy LED multiple Color Lighting Waterproof Oak Shower floor Grid Accessory Rack Circulation Fan Alcove Free Standing Unit Removable Wood Stools UNIT INFORMATION WS112 32 WS112 36 WS112 40 WS112 32 WS112 36 WS112 40 STRAST RA SR A SJ RAJ SI K S K S S K S RS S AL NSE SII NI A SJ SII NIINI S K S S K S KIK STRAST RA RER RA SJ RAJ SIR S K ENS Nm Electric Parameter Voltage Length Width Height Steam Ready 1 2 minutes optimum room temperature reached within 2 5 MIN 220V 60 50Hz 1500mm 59 Inch 813mm
11. oo STEAM PLANET Royal Care Series Installation amp Operations Manual WS 112 Note You must read all installation amp operation instructions prior to assembly and use of this unit l Page Rev 9 2012 Table of Contents Tools Needed for Installation Product Features Unit Information Electrical Information Plumbing Requirements General Information Base Information Assembly amp Installation Cleaning amp Maintenance Steam Generator Cleaning General use amp Maintenance Control Parts Information PP oR ed alr PO o y ESA LCD Display Information caras Control Panel Diagram Pe PE Control Procedures arcaica corra LE Wireless FM Transmitter Information e o E Troubleshooting O OP e ER O o lo o CO MO OU RR PR A WW Ww Thank you for selecting Steam Planet Corp Computerized Steam Rooms In order to operate and use the product properly please follow all instructions provided in this User s Manual Our company reserves the right to change the Manual at anytime The manual takes effect the date itis published This manual shall prevail if there is any difference between this and previous documents and manuals WARNING Note Within the Warranty period please don t take off the decals from the computer control boxes and the steam generator without manufacturer s permission Have only licensed professionals install or perform any maintenance Generally our technicians can troubleshoot most problems over the ph
12. placement All Stone shower bases may need to be set and leveled in place on a bed of thin set mortar Itis advised to have base onsite before preparing drain location Access near controls and Jets Is recommended Manufacturer reserves the right to change specs or features at anytime Please check to confirm details 1 866 783 2661 4 Page Rev 9 2012 BASE OPTIONS The standard WS 112 shower enclosure does not include a base It can be installed over a custom or existing base of your choice Steam Planet offers two base options 1 An Acrylic base connected to a steel frame with adjustable feet for leveling 2 A man made cultured stone base Black or White that sets into place or may require some type of cement thin set mortar foundation Y ou will find information regarding these bases below 1 OPTIONAL ACRYLIC BASE Base needs to be set in place and leveled All feet must be touching the floor to support the unit IF YOU PLAN TO ATTACH THE DRAIN FIRST YOU MUST LEVEL THE BASE IN ITS FINAL RESTING PLACE Note The flexible drain hose included with this unit is for installation into a floor drain only Substituting the existing drain setup for a setup of the installers choice will not void the warranty of the unit as long as there is no evidence of misuse or damage to the base h 59 inches Height is adjustable 6 7 5inches 2 OPTIONAL STONE BASE Stone Base needs to be set in the final resting space and levele
13. ter is not Change thermal switch installed inside the working no steam from generator heater 5 The heater is not working Change the heater 6 The water supply is shut off Open water valve 1 The water inlet electromagnetic valve is not shutting off Replace water inlet valve Steam generator keeps adding water 2 Water level sensor cannot detect Clean scale of water level sensor or signal replace it 1 There is short circuit from heater Replace heater Power supply is off when on off button is pushed 2 There is short trom thermal switch Water leaks from valve The seal is damaged Change the seal Water flow volume is low Water supply has clogged filter Clean Filter For additional help call Steam Planet Corp at 1 866 STEAM 61 14 Page Rev 9 2012 15 Page Rev 9 2012 007 STEAM PLANET
14. tton when the FM radio is on Push VILA to adjust the volume Display will show DB e Frequency m Touch this button when the FM radio is on Push the ILA again to adjust the frequency Display will show MHZ 11 Page Rev 9 2012 E LH Channel Memory Channel Memory Setting O O O Start FM Radio To set your favorite station press button to desired memory position 1 8 set the desired station then press and hold button for 5 seconds The display will shift and memory will be saved Adjust FM Radio to your favorite channel touch button to adjust frequency and volume Channel Memory Touch button for more than 3 seconds the figure shows 1 and turns to original setting station number Release button to finish setting for one channel If the station number is used for another channel this channel will be replaced by the new channel in memory Repeat the above steps to save channels in memory Maximum 8 channels can be memorized Find Channel O Start FM Radio Touch button to find right channel in memory adjust v adjust o The above 2 buttons are used to adjust frequency and volume 12 Page Rev 9 2012 WIRELESS FM TRANSMITTER Lo Audio Signal Input On ofl USB Interface Transmitting Frequency adjusting Transmitting Frequency adjusting Transmitting Channel adjusting Transmitting Channel Memory Transmitting Channel adjusting On Off Push and hold th

Download Pdf Manuals

image

Related Search

Related Contents

• Owners Manual • Mode d`emploi • Manual del propietario  Samsung 1100DF Computer Monitor User Manual  Model 2520 Pulsed Laser Diode Test System Service Manual  Istruzioni per l`uso ed il montaggio  Bracketron UGC-465-BL mobile device charger  Ametek DTI-050 Temperature Indicator Data Sheet PDF  VM-366A USER MANUAL  