1. DO NOT allow persons to operate this type of device who are not qualified Most damages are the result of operations by nonprofessionals DO NOT shake device avoid brute force when installing and or operating When installing device overhead in a suspended location always install with an appropriate safety cable When installing the fixture in a susoended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to transport the device in for service 9 EWDMX IP User Manual ver 1 www elationlighting com DEVICE OVERVIEW Transceiver PS me o LINK DATA ELATION 606608 o SIGNAL a On iim AL EWDMXIP Antenna Dmxin Dmx Out Powerin Drain Tap FUNCTION SIGNAL In Receiver Mode Indicates strength of receiving wireless signal 00000 20 40 60 80 100 In Transmitter Mode Indicates Operating Mode See page 14 for more details TX RX Indicates current operating mode of the unit TX Transmitter Mode RX Receiver Mode LINK TX Transmitter MODE LED INDICATOR ON Normal Operation FLASH Unlinking All Wireless Receivers RAPID FLASH Linking With All Wireless Receivers LINK RX Receiver MODE LED INDICATOR ON Not Linked To A Wireless Transmitter FLASH Linked To A Wireless Transmitter RAPID FLASH Linking To A Wireles
2. 5 EWDMX IP User Manual ver 1 www elationlighting com WARRANTY REGISTRATION Please complete and mail in the enclosed warranty card or register online http www elationlighting com Login asox to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and generdl user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 6 EWDMX IP User Manual ver 1 Et ATION www elationliahting com Qe 9 9 LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional produ
3. 00m Wireless DMX Range See page 12 for more information FHSS Frequency Hoping Spread Spectrum 1 800 tps Datasafe Tech Wireless Fidelity and Error Correction Invisi wire High Fidelity Tech Output Matches Input Easy To Use Single Push Button Function Control RDM Remote Device Management Support 2 4GHz Radio License Free Worldwide TDMA Time Division Multiple Access W DMX G4 Protocol Support Rugged Hard Plastic Case single DMX 512 Universe CONTROL CONNECTIONS Multi Function Single Push Button Antenna Port IP Rated 3pin Male 3pin Female Attached DMX In Out Cables IP Rated 3pin Attached Power In Cable SIZE WEIGHT Length 9 4 240mm Width 6 7 170mm Vertical Height 2 2 56 5mm Weight 4 6 Ibs 2 1kg ELECTRICAL THERMAL AC 100 240V 50 60Hz 3W Max Power Consumption 14 F 10 C to 113 F 45 C APPROVALS RATINGS CE IP65 DIMENSIONAL DRAWINGS 6 7 170mm 2 2 EWDMXIP 56 5mm 9 4 240mm Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 16 EWDMX IP User Manual ver I www elationlighting com OPTIONAL ACCESSORIES 17 EWDMX IP User Manual ver I
4. AUDIENCES and or GROUND LEVEL with a DIRECT LINE OF SIGHT Tx Antenna to Rx Antenna and with 80 or greater signal strength See diagram below _ 1 640ft 500m 9 8 ft 3m CHD Above Ground s Transmitter Receiver Mode Mode 12 EWDMX IP User Manual ver I www elationlighting com OPERATION GUIDE SYNCRONIZING RECEIVERS TO A TRANSMITTER iS Note You can add receivers af any time even during operation 1 Power on the RECEIVER unit s and ensure that they are not linked with any other TRANSMITTER LINK indicators should be OFF and RX indicator should be ON If the units are linked follow the instructions in the next section to unlink receivers 2 On the TRANSMITTER unit press and release the RED FUNCTION button quickly The TRANSMITTER will scan for all unlinked RECEIVERS for a period of ten seconds the LINK indicator will flash rapidly If successful each RECEIVER s LINK and SIGNAL indicators will go ON If failed i e the LINK indicator fails to go solid after 10 seconds on the RECEIVER check if the RECEIVER is in range and repeat the procedure CLEARING A RECEIVER LINK TO A TRANSMITTER On the TRANSMITTER unit press the RED FUNCTION button and hold for 3 seconds All display LEDs will go out and the LINK LED will be blinking slowly Release the RED FUNCTION button at this point and all connected RECEIVERS will be unlinked TO UNLINK AN INDIVIDUAL RECEIVER On the RECEIVER press and hold the RED FU
5. ELATION EWDMXIP user manual EWDMX IP user manual PROFESSIONAL ELATION www elationlighting com 2015 ELATION PROFESSIONAL oll rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their resoective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Th
6. NCTION button until the LINK indicator goes OFF except for POWER and RX indicators The RECEIVER is now unlinked SWITCHING BETWEEN TX AND RX MODES The EWDMX IP can switch between transmit and receive modes allowing the unit to be used as a TRANSMITTER or a RECEIVER 1 Remove power from the unit by disconnecting the power cable 2 Push and hold the RED FUNCTION button 3 Reconnect power while still holding the RED FUNCTION button 4 Release the RED FUNCTION button 5 The TX TRANSMITTER or RX RECEIVER LEDs indicate the mode of the unit 13 EWDMX IP User Manual ver 1 www elationlighting com G3 G4 MODES amp RDM OPERATION EWDMX IP can change between Generation 3 protocol compatibility for older Units and the new Generation 4 protocol which supports Invisiwire Datasafe and RDM Remote Device Management G4 receivers automatically detect the mode the transmitter is in so you only need to change the mode of the transmitter to change the mode of the entire system When the protocol mode has been changed receivers need to be re connected to their respective transmitters TO CHANGE MODES 1 Hold down the RED FUNCTION button for over 10 seconds Initially you will see the LINK light blink slowly Do not release the RED FUNCTION button at this point as this will disconnect all RECEIVERS Wait until you see the ALL of the LEDs light up then the RED CIL light illuminate before releasing the RED FUNCTION button 2 Pres
7. been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully insoect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our Customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS e 1 IP Rated Power Cable e 1 IP Rated 3pin Male DMX Input Cable e 1 Clamp Mounting Bracket amp 2 Screws e 1 Safety Cable e Manual amp Warranty Card CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issue please contact Elation Professional ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu
8. cts to be free of manufacturing defects in material and workmanship for a period of two years 730 days and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months 180 days from the original date of purchase This warranty excludes discharge lamps and all product accessories This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional amp factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If any product is sent it must be shipped in its original package and packaging material No accessories should be shipped with the product If any accessories are shioped with the product Elation Professional shall have no liability what so ever for loss and or or damage to any such accessories nor for the safe return thereof C This warranty is void if the product serial number and or labels are altered or removed if the product is modified in any manner which Elation Professional conc
9. de by Elation Professional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty periods set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said periods have expired The consumer s and or dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional be liable for any loss and or damage direct and or consequential arising out of the use of and or the inability to use this product G This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 7 EWDMX IP User Manual ver 1 www elationlighting com SAFETY INSTRUCTIONS This device is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this device due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device is grounded properly and only qualified personnel perform all electrical connections For proper operation onl
10. e Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu DOCUMENT VERSION IEY Please check www elationlighting com for the latest revision update of this manual Document Version 8 17 15 Updated manual format 2 EWDMX IP User Manual ver 1 www elationlighting com CONTENTS Sgeyn o 9 eeneae i Device Installation 11 Installation Location Guidelines Operation Guide Technical Specifications Optional Accessories 3 EWDMX IP User Manual ver 1 www elationlighting com GENERAL INFORMATION CRC Corrosion Resistant Coating INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable wireless DMX IP rated devices on the market today Ihe device has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance IP65 RATED An IP rated device which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress entry of external foreign objects such as dust and water The International Protection IP rating system is commonly expressed as IP Ingress Protection followed by two numbers i e IP65 w
11. here the numbers define the degree of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated device such as the EWDMX IP is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this device is IP rated the device is NOT suitable for marine and or coastal environment installations Installing this device in a marine and or coastal environment may cause corrosion and or excessive wear fo the interior and or exterior components of the fixture Damages and or performance issues resulting from installation in a marine and or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and or repairs Ensure ALL connections and end caps dre properly sealed with a non conductive dielectric grease available at most electrical suppliers to prevent water ingress condensation and or corrosion OPTIONAL CORROSION RESISTANT COATING Optional Corrosion Resistant Coatings may be available for this device Please consult your Elation Professional sales representative for details A EWDMX IP User Manual ver 1 www elationlighting com UNPACKING Every unit has
12. ith a dielectric grease available at most electrical suppliers to prevent water corrosion and or electrical short circuit INSTALLATION VIA INCLUDED BRACKET TRUSS MOUNTING INSTALLATION 1 Insert the quick lock fasteners of the included bracket into the respective holes on the bottom of the device Tighten the quick lock fasteners fully clockwise 2 Loop the safety cable through the opening on the bottom of the base indicated by red arrow and over trussing system or a safe fixation spot Hook end of the safety cable on to the attached carabineer PERMANENT INSTALLATION 1 Remove attached mounting bracket and set on a flat surface or secure to a wall using the 2 slotted screw mounting points 11 EWDMX IP User Manual ver I www elationlighting com INSTALLATION LOCATION GUIDELINES Wireless DMX signal can penetrate walls glass metal and most objects However there are many factors that can affect and or interrupt the wireless DMX signal one of which is people Therefore it is highly recommended to position the wireless antenna a minimum of 9 8 ft 8m above audiences and or above ground level Careful planning and testing of the selected installation location is critical to ensure optimum and reliable wireless DMX operation The maximum wireless DMX range is up to 1 640 ft 500m based on general testing of the EWDMX IP in an outdoor urban area with normal interference installed in a location 9 8 ft 8m ABOVE
13. ludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional amp factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with the products described above Except to the extent prohibited by applicable law all implied warranties ma
14. s Transmitter DATA Both modes TX RX Indicates presence of a wireless DMX signal G4 Both Modes TX RX Indicates G4 mode is active RDM Both Modes TX RX Indicates presence of RDM signal CTRL Both Modes TX RX Indicates Control mode is active POWER Both Modes TX RX Indicates device is receiving required AC power FUNCTION BUTTON Used to activate modes as listed above 10 EWDMX IP User Manual ver I www elationlighting com DEVICE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5 0 ff 1 5m away from any flammable materials decorations pyrotechnics etc ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and or installations ie CAUTIONS For added protection mount the device in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture e Before mounting the device to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture e Device installation must always be secured with a secondary safety attachment such as an appropriate safety cable e Never stand directly below the device when mounting removing or servicing e The applicable operating temperature for the device is between 10 C to 45 C Do not use the device under or above this temperature range lie e Ensure ALL connections and end caps are properly sealed w
15. s and release the RED FUNCTION button to change between the 3 modes Note that each time the RED FUNCTION is pressed the unit will toggle between all the different modes 3 Once the desired mode is set power cycle the unit to begin use in that mode The Following Modes Can Be Set gt G4 2 4GHz First green SIGNAL indicator on the left and G4 Light is static on gt G4 RDM First green SIGNAL indicator on the left is off but G4 Light is static on gt G3 2 4GHz First green SIGNAL indicator on the left is static on but G4 Light is off eS Note Units ship standard as G3 2 4GHz for backward compatibility reasons 14 EWDMX IP User Manual ver I www elationlighting com SWITCHING RDM MODE 1 On the TRANSMITTER enter G4 RDM mode 2 Press the RED FUNCTION button to enter the control mode TX LINK DATA G4 RDM PWR and three middle SIGNAL indicators are static ON 3 On the RECEIVER RX and PWR indicators are static ON If not please unlink the individual RECEIVER 4 If all LED indicators above light formally press the RED FUNCTION button on the TRANSMITTER quickly LINK lights on TRANSMITTER and RECEIVER will blink successfully switch to RDM mode if RX LINK DATA G4 RDM PWR and SIGNAL indicators are static ON 15 EWDMX IP User Manual ver 1 ECATIOW www elationlighting com Cn 9 9 TECHNICAL SPECIFICATIONS FEATURES IP65 Wireless DMX Transceiver with 2dbi Outdoor Antenna Up To 1 640 ft 5
16. y qualified and certified personnel should perform installation of this device Do not attempt installation and or operation without proper knowledge how to do so Any modifications to this device will void the original manufactures warranty and increase the risk of damage and or personal injury Always disconnect from main power source before performing any type of cleaning procedure and or when this device is not in use Only handle the power cord by the plug end never pull out plug by tugging wire the cord Do not operate device if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating DO NOT operate device in locations above 113 F 45 C or below 14 F 10 C DO NOT operate device in areas subject to extreme vibrations or bumps Please make sure there are NO FLAMMABLE MATERIALS close to this device while operating to prevent any fire hazard Do not permit operation by persons who are not qualified for operating this type of device Most damages are the result of operations by nonprofessionals Please use the original packaging and materials to transport this device in for service 8 EWDMX IP User Manual ver 1 www elationlighting com GENERAL GUIDELINES Device must be installed in a location where the antenna is not blocked or hidden from view DO NOT attempt installation and or operation without knowledge how to do so
Download Pdf Manuals
Related Search
Related Contents
POLARIS COMFORT POLARIS Touch Panel 耐圧防爆積層信号灯 FICHA TECNICA ZERAMIC EXTREM W cubiertas texte integral Sony CXS-GT08HP Installation/Connections Manual Klipsch R-12SW subwoofer Sanyo VPC-GH1GX User's Manual Mode d`emploi pour la synchronisation à partir d`une Status Reports Copyright © All rights reserved.