1. Omnicell Model 9106 FB APPROUED a Ze a m Al DE i 3 a i i Es 51176 2007 by Fairbanks Scales Inc Revision2 10 07 All rights reserved Amendment Record Omnicell 9106 FB DOCUMENT 51176 Manufactured by Fairbanks Scales Inc 821 Locust Street Kansas City Missouri 64106 Created 08 2007 Revision 0 08 2007 Preliminary Release Revision 1 09 2007 Documentation Release Revision 2 10 2007 Specifications Update 51176 Rev 2 Disclaimer Every effort has been made to provide complete and accurate information in this manual However although this manual may include a specifically identified warranty notice for the product Fairbanks Scales makes no representations or warranties with respect to the contents of this manual and reserves the right to make changes to this manual without notice when and as improvements are made It is the responsibility of the requesting party to develop maintain install and connect networking devices and general network connectivity as it applies to the originating party s network No warranty or guarantee expressed or implied concerning the network its design its installation or operational characteristics has been offered by Fairbanks Scales Fairbanks Scales shall not be liable for any loss damage cost of repairs incidental or consequential damages of any kind whether or not based on express or implied warranty contract negligence or strict liabi
2. lead tech must be prepared to recommend the arrangement of components which provide the most efficient layout utilizing the equipment to the best possible advantage e The warranty policy must be explained and reviewed with the customer 10 07 9 51176 Rev 2 AE AT ADDED FAIRBANKS uw Vz Section 2 Installation Pre Installation Checklist The following points should be checked and discussed with the Area Sales Manager and or customer if necessary before the technician goes to the site and installs the equipment v Check the customer s application to make certain it is within Ly the capabilities and design parameters of the equipment v If the installation process might disrupt normal business operations tell the customer and ask that they make ample arrangements v Is properly grounded power available at the installation location Be sure that the equipment operator s are available for training v The service technician must thoroughly review the installation procedures v The service technician reviews the recommended setup with the Area Sales Manager or Area Service Manager and together they identify all necessary variations to satisfy the customer s particular application Unpacking Follow these guidelines when unpacking all equipment v Check in all components and accessories according to the customer s order v Remove all components from their packing material checking against the invoice that they are accou
3. 0 000 Ib Capacity Shear Beam Load Cell 9106 FB Series Omnicel 10 07 14 51176 Rev 2 gt Section 3 Parts Parts Not Supplied Qty _ Per Ass y Components Fastening Bolts for Vessel Attachment 1 2 13 UNC bolts 5 000 capacities and under 1 2 13 UNC Anchor Bolts 5 000 capacities and under 5 8 11 UNC bolts 10 000 capacity 10 07 5 8 11 UNC Anchor Bolts 10 000 capacity 15 51176 Rev 2 PSA Section 3 Parts ae NA Omnicell 9106 FB Parts Fairbanks Diagram P N Letter Qty Components 9106 FB Mounting Ass y 1 000 Ibs to 5 000 SE Assembly includes the following parts without a load cell SS Base Plate 7 SS Top Plate z SS Load Cell Shim Spacer 7 Hex Bolt 1 2 13 2 25 Lock Washer 1 2 Split Ring Box Hex 1 2 20 3 0 Full Thread 7 Spherical Washer Set 1 2 z Nut 1 2 20 9106 FB Mounting Ass y 10 000 Ibs Assembly includes the following parts without a load cell SS Base Plate SS Top Plate SS Load Cell Shim Spacer Hex Bolt 3 4 10 3 0 Lock Washer 3 4 Split Ring Box Hex 3 4 16 3 5 Full Thread 7 Spherical Washer Set 3 4 n Nut 3 4 16 Item s not shown on diagram zioInmo un gt 1 1 1 1 2 1 1 2 zI on m io u gt Nlialainla a a a HEX BOLTS E LOCKING WASHERS PN E B Pa SPHERICAL WASHERS H HEX BOX G NUTS 1 S
4. 176 Rev 2 PASS a4 FAIRBANKS aussy s ro nS SN Section 2 Installation INSTALLATION o m A q Basic Assembly Steps Raise the vessel that is to be supported by the Omnicell Assemblies Secure the Assembly by safely placing blocks under the vessel to the required height Place each Assembly onto a level surface under each support leg Setthe Assemblies for the correct load cell orientation as shown on the following page Insert the four 4 1 2 13 bolts 5 000 capacity and under or 5 8 11 bolts 10 000 capacity and then fasten them loosely to the support leg for each assembly Mark the location of the anchor bolt locations Slide the assembly back and drill the anchor hole locations Re position the load cell assemblies level and install the anchor assemblies Lower the vessel onto the top plate of each Omnicell Assembly 10 Tighten the bolts securing the load plates to each support leg of the vessel 11 Remove all cribbing blocks 12 Route the cables to the junction box and indicator 13 Wire the Omnicell Assemblies according to the appropriate junction box and indicator service manual Before the installation is considered complete the equipment is to be configured to meet or exceed any applicable weights and measures requirements 10 07 12 51176 Rev 2 ra s za Section 2 Installation uurs ne Omnicell Placement Load carrier symbol Center of gravity Figur
5. 50 5 00 0 56 2 00 4 00 0 70 4 00 0 63 10 000 Ibs 8 50 5 00 5 50 5 00 0 75 3 00 4 00 0 94 5 00 0 69 Wiring 07 1 1 E ee D Green Excitation Black Excitation White Signal Red Signal 10 07 7 51176 Rev 2 NAS SPECIFICATIONS damen FATRBANRS Section 1 General Information usw Capacities 1 000 1 500 2 500 5 000 and 10 000 Ibs Mount Construction 304 Stainless Steel Full Scale Output FSO 3 0mV v 0 25 Combined Error FSO lt 0 03 Non Linearity FSO lt 0 03 Hysteresis FSO lt 0 02 Creep Error 30 min lt 0 03 Compensated Temperature 14 to 104 F 10 C to 40 C Operating Temperature 40 to 176 F 40 to 80 C Excitation Voltage 5 15 VDC Mechanical Overload e Safe 150 e Ultimate 300 Sideload Safe 100 Bridge Resistance 350 ohms nominal Load Cell Construction Stainless Steel 17 4 PH 10 07 Sealing Welded Seal Cable 20 ft Polyurethane Protection IP 67 Approvals Factory Mutual Approved APPROVED 51176 Rev 2 Section 2 Installation GENERAL SERVICE POLICIES Phases of Installation 1 Verifying the application Unpacking amp equipment checkout Installation amp adjustments bh OO N Customer check off and site readiness Conferring with Our Client e The
6. LOAD CELL SHIM 6 BASE PLATE A 10 07 16 51176 Rev 2 Manufactured by Fairbanks Scales Inc 821 Locust Street Kansas City Missouri 64106 www fairbanks com Omnicell Model 9106 FB INSTALLATION MANUAL DOCUMENT 51176
7. e 3 Follow these guidelines for installing Omnicell Load Cells 1 The loading points of the modules should be as far from one another as the structure allows 2 When installing the square and rectangle Omnicell units line up the Base Plates of the Load Cells with each other and align them evenly from the end and the sides of the units 3 When installing six Load Cells Figure 5 be extremely careful to position the center Omnicells to exactly the same height as the outer Omnicells Figure 5 10 07 13 51176 Rev 2 Section 3 Parts Omnicell 9106 FB Complete Units Part No Description Omnicell w Fabricated SS Mount SS Welded Load Cell 1 000 Ib Capacity Omnicell w Fabricated SS Mount SS Welded Load Cell 1 500 Ib Capacity Omnicell w Fabricated SS Mount SS Welded Load Cell 2 500 Ib Capacity Omnicell w Fabricated SS Mount SS Welded Load Cell 5 000 SE Capacity Load Cells LCF Part No Number LCF 9100 27 Omnicell w Fabricated SS Mount SS Welded Load Cell 10 000 Capacity Description Stainless Steel Welded Shear Beam Load Cell 1 000 Ib Capacity LCF 9100 28 Stainless Steel Welded Shear Beam Load Cell 1 500 Ib Capacity LCF 9100 29 Stainless Steel Welded Shear Beam Load Cell 2 500 Ib Capacity LCF 9100 30 Stainless Steel Welded Shear Beam Load Cell 5 000 SE Capacity LCF 9100 31 Stainless Steel Welded Shear Beam Load Cell 1
8. lity arising in connection with the design development installation or use of an intended network Copyright 2007 This document contains proprietary information protected by copyright All rights are reserved no part of this manual may be reproduced copied translated or transmitted in any form or by any means without prior written permission of the manufacturer 10 07 4 51176 Rev 2 Table of Contents SECTION 1 GENERAL INFORMATION coccccccccccccccccccccncncnncnnnnnnnnnncnnonnnnonnnnnnnenennnnos 6 Descripti n se dancer 6 PG AUU NSS 5 PFENPPPEFEESERREPFEUSPEFBEUFPREFBEUHPTEERPEERS PEFRFEUSSTEUFITERFFRESCEHFFGERRERTEUEREERLES E aE EE RE 6 Applicaton Sensen dali 6 Dimensions In INCHES 2200022200nnnaunnnnsnnnnennnnnnnnnnannnnnnnennnnanannnnnnnersnnrnnnnnannnnnnnnrennnnannnnn 7 WINO nennen 7 Specification hear 8 SECTION 2 INSTALLATION use a n 9 General Service Policies 444444444444nnnnenneenneennnennnenneennne nennen nennen nenn 9 Phase5 0f Installation nenn a laa cis 9 Conferring with Our Client ea en ee E dials 9 Pre Installation Checklist ccccccssscccssssececssessececsenesecsesueeecseeeeecsesueeecseeeeeceeeeeeesseeeneeseeeneseeeeenes 10 Unpacking A de elie ieee i eee ee ee 10 Users Responsibilities iii etree eens anna eden oases 11 Installation nsss a e 12 Basic Assembly Steps 0un220unnsannnnannnnnnunnnnnnnesnnnnnnnnnnnnnnesnnenannnnnannnsnnn
9. nnsnnanannnnnnnnnsnannnannnnn 12 Omnicel Placement einen ee ee 13 SECTION 3 PARTS 14 Omnicell 9106 FB Complete Units uanananeaneanennenennennennnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnannn 14 Load Cels an en elle ersehnte sinken 14 Parts Not Supplied 2222er A a 15 Omnicell 9106 FB Parts comicidad E E AAA AAA AAA 16 10 07 5 51176 Rev 2 Section 1 General Information DESCRIPTION Fairbanks Omnicell 9106 FB Series is a single ended beam weighing assembly It is a cost effective choice for medium to high capacity non commercial weighing applications requiring protection from extreme hostile and washdown environments FEATURES Medium to High Weight Ranges e Designed for non commercial applications e 1 000 to 10 000 Ib capacity models e Integral height adjustment on the receiver plate for easy load balancing e Articulating mounting plate which accommodates non planar misalignments of up to four degrees 4 e Load Cells constructed from 17 4 PH Stainless Steel Load Cells e Mount constructed with 304 Stainless Steel e Low profile design with integral height adjustment e Factory Mutual approved for hazardous applications APPLICATIONS e High Accuracy e Tanks e Bins e Process Reactors e Mixing e Blending e Hostile Environments e Hoppers e Batching 10 07 6 51176 Rev 2 Section 1 General Information E d Dimensions In Inches CAPACITY A 1 000 5000 Ibs 7 12 4 00 4
10. nted for and not damaged Advise the shipper immediately if damage has occurred Order any parts necessary to replace those which have been damaged Keep the shipping container and packing material for future use Check the packing list v Collect all necessary installation manuals for the equipment and accessories v Open the equipment and perform an inspection making certain that all hardware electrical connections and printed circuit assemblies are secure v Do not reinstall the cover if the final installation is to be performed after the pre installation checkout 10 07 10 51176 Rev 2 ARE Section 2 Installation User s Responsibilities 1 All electronic and mechanical calibrations and or adjustments required for making this equipment perform to accuracy and operational specifications are considered to be part of the installation They are included in the installation charge Only those charges which are incurred as a result of the equipment s inability to be adjusted or calibrated to performance specifications may be charged to warranty 2 Absolutely no physical electrical or program modifications other than selection of standard options and accessories are to be made to this equipment Replacement of individual components is not allowed The assemblies must be properly packaged in ESD protective material and returned intact for replacement credit per normal procedures 10 07 11 51