1. A dad 50 NMONA NMONE o ld usT O9LSHY I 1SM SLuvd Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 15 of 15
2. RADIO RECEIVING CHANNE CH SW FREQ DTMF DIGIT SET 23 4 5 6 O 4 0080 FIGURE 2 SURFACE MOUNTING RADIO DTMF ACTIVATOR Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 5 of 15 II SPECIFICATIONS Specifications Input Power 8 to 35 volts DC 160 milliamperes max 8 volts lower current at higher voltages diode protected against reversed polarity Radio Programmable VHF 8 synthesized channels Temperature Range Operational 30C 22F to 60C 140F Storage 40C 40F to 80C 176F Size Relay Rack mounting version overall dimensions are 4 3 4 x 9 3 4 x 7 Wall mounting version overall dimensions are 8 3 4 x 7 3 4 x 4 3 8 Weight 5 pounds Isolation Tested to 2000 VAC between case and each terminal CONNECTING AN ANTENNA WITH A GROUNDED SHIELD WILL GROUND THE POWER SUPPLY NEGATIVE THE USER MUST DETERMINE ELECTRICAL ISOLATION REQUIREMENTS FOR EACH INSTALLATION Surge Protection 1500 Watt 36 Volt TVS between Power and Ground Relay Contacts Relay contact rated 1 amp 30 VDC One Form C contact available Front contact Back Contact and Contact Heel Terminals Standard 1 4 signal type terminals for power and relay contacts DTMF Code 1 6 digit selected with rotary switches on front panel The DTMF detector resets after app 2 seconds without decoding a di
3. SCHEMATIC OF DUAL RELAY W JUMPER V SERVICE amp ORDERING Warranty The Radio DTMF Activator comes with a one year parts amp labor warranty If repairs become necessary during this period call the factory for a Returned Material Authorization RMA number Send the unit to the factory freight prepaid with the RMA number on the outside Include contact information and a description of the problem Damage due to abuse and misuse are not covered Post warranty repairs If repairs become necessary after the warranty period phone support is available to assist you in performing repairs You can also send the unit to the factory for repair Call first for an RMA number send the unit freight prepaid with the RMA number on the outside and contact information and a description of the problem on the inside Consult the factory for charges Ordering Information In order for us to configure your Activator appropriately we need certain information at the time of ordering 1 Mounting method either signal rack or wall mount 2 Operational Mode 3 Frequency band e g VHF and model of radio desired and 4 A list of up to eight radio frequencies and or AAR channels to be programmed into the radio The first three items are incorporated into the part number see below 14 99005V2 xyz Radio DTMF Activator with options x y and z Options X Mounting Method A Signal Rack Mounting B Wall Mounting y Operationa
4. Antenna The Radio DTMF Activator is often used to receive radio transmissions from a short distance typically several hundred yards or less so that an antenna is not typically necessary The DTMF Activator comes with an antenna shorting plug about 2 long provides least sensitivity and a 50 Ohm Load about 6 long provides greater sensitivity but ot as much as an antenna and the radio receive sensitivity is programmed high enabling the radio to receive from a nearby radio even when mounted in a metallic building If however an antenna is used a short handheld type antenna may be mounted directly to the radio via BNC connector The Carrier Detect may have to be reprogrammed if an antenna is used Alternatively an antenna may be mounted elsewhere and connected via cable Note that if the antenna s shield is connected to earth ground the power supply return will be grounded also If this is not acceptable in your application you must then use an isolating power supply WARNING Attaching an antenna with grounded shield will cause the power supply return to be grounded Radio Programming The radio has been programmed at the factory and the frequencies are listed on the label on the front of the Activator If the radio is to be re programmed e g to change channels or to adjust receive sensitivity the radio or the entire Activator may be returned to Miller Ingenuity for reprogramming Depending on the situation t
5. for surface mount circuit board updated contact info Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 2 of 15 I INTRODUCTION DESCRIPTION amp APPLICATIONS The LMG 14 99005V2 xyz Radio DTMF Activator provides radio controlled relay contacts for control of gates switches and other equipment It is available in signal relay rack and surface mounting configurations Multiple operational modes are built into the unit and are user selectable a Description The Radio DTMF Activator includes a radio receiver circuit board and connecting cables enclosed in a metal case which is mounted on a heavy duty phenolic base The phenolic base provides electrical isolation See specifications for more information NOTE IF AN EXTERNAL ANTENNA WITH GROUNDED SHIELD IS CONNECTED TO THE RADIO DTMF ACTIVATOR THIS WILL GROUND THE POWER SUPPLY THE USER MUST EVALUATE GROUND ISOLATION REQUIREMENTS FOR THE PARTICULAR INSTALLATION The radio receiver is programmable and synthesized Any of the eight frequencies programmed into the radio may be selected with the rotary switch on the front of the unit The circuit board includes power conditioning circuitry and a 1 6 digit DTMF decoder The DTMF digits are programmed with rotary switches on the front of the unit Currently 14 operational modes are available for your Activator Specify your mode choice as a portion of the part number of your Activator Th
6. switch positions 0 9 correspond the DTMF 0 9 switch positions A B amp C correspond to DTMF A B amp C switch position D signifies end of code and switch positions E amp F correspond to amp ff Examples To set the code to 1 5 3 set the switches to 1 5 3 D The positions of the 5 amp 6 switches are irrelevant in this example Selecting radio channel Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 8 of 15 The list of channels programmed into the radio is normally affixed to the front of the unit near the Radio Channel Select switch Find the frequency you need in the list and turn the Select switch to the corresponding position Timer The 14 99005V2 Model has several modes that use a timer adjustable in 1 second 10 second or 1 minute intervals The time is selected using the Time Set rotary switch on the front panel Switch positions 1 15 each correspond to one time increment For modes with 1 second increments positioning the Time Set switch to 5 will result in a relay active time of 5 seconds for modes with a 10 second interval 50 seconds and for modes with a 1 minute interval 5 minutes Putting the switch to the 0 position disables the unit When in modes that do not use the timer the position of the Time Set switch has no effect on the operation of the Activator except that the 0 position disables the unit
7. 15 10 Code then enables relay 1 Code then enables relay 2 Timer 1 minute per increment 11 Code then then xxx enter time in seconds I E to enable the relay for 19 seconds you would enter 123 019 assuming the code of the unit was 123 12 Code then then xxx enter time in minutes I E to enable the relay for 27 minutes you would enter 123 027 assuming the code of the unit was 123 13 Code then to turn relay on or Code then to turn relay off Timer 10 sec per increment Note Same as Mode 6 except the and are switched When the Activator is in a mode utilizing timed relay operation modes 1 2 3 5 6 7 8 9 10 13 the TIME SET switch on the front panel determines the amount of time the relay will remain energized once the proper DTMF code has been detected if the relay off command has not been sent in modes 5 6 7 and 13 Switch positions 1 15 correspond to 1 15 time increments respectively If the DTMF code is detected again during this time the timing cycle will re initialize The time increments are each 1 second or 10 seconds or 1 minute depending on mode Radio Receiver The Radio Receiver used is a Ritron DTX Plus transceiver Only the receiver section of the radio is used in this device Larry McGee Company reserves the right to substitute a receiver transceiver of similar specifications See S
8. 4 99005V2 06rA Page 11 of 15 OPERATING UNITS USING RELAY ON RELAY OFF Modes 0 4 e InMode O the relay status on or off changes every time the proper DTMF code is decoded e In Mode 4 the relay is turned ON when the proper DTMF code followed by a is decoded and it is turned off when the proper DTMF code followed by a is detected This mode corresponds to the B operational style in the original generation of Activators OPERATING UNITS USING TIMED ONLY MODES Modes 1 2 3 8 9 10 11 12 and 13 e In Modes 1 2 and 3 the relay is turned on whenever the proper DTMF code is detected and stays on according to the setting of the Time Set Switch Mode 2 10 second increments corresponds to the A operational style in the original style of Activators e In Modes 8 9 and 10 Relay 1 will energize when the proper DTMF code followed by a is detected NO contacts closed on energizing Relay 2 will energize whenever the proper DTMF code followed by a is detected NC contacts opened on energizing The relay will remain energized according to the setting of the Time Set Switch Repeating the DTMF code while the relay is still energized will reset the timer If the DTMF code for the unenergized relay is received while the other relay is energized the energized relay will become deenergized and the 2 relay will energize Mode 8 with 1 second increments corresponds to the C operationa
9. Larry McGee McGee DIVISION OF MILLER INGE NUIT Radio DIMF Activator Model No 14 99005V2 xyz To avoid damaging the internal relay ensure that 5 4 iy e power supply positive and e IRE ET DTMF pe ja se 2 AG 49999 power supply negative are connected to the B12 and N12 terminals respectively TIME RADIO 9 Grece Nne powER Q mer RADET GANG E 5600 AA 160 6950 392 1400 160 ai 160320 1 nd a DO aar 13 a 161 NSOE 6 85 ruse Installation Operation amp Service Manual Manual P N PM 14 99005V2 06rA 01 2015 Miller Ingenuity 1155 East Eighth St Winona MN 507 452 2461 www milleringenuity com Foreword The Radio DTMF Activator is designed to provide reliable remote control by radio in an easy to install and compact package It is available in two form factors to make installation in many situations extremely easy Version 2 of the radio DTMF Activator 14 99005V2 released in January 2006 incorporates several operational modes into each unit Previously each Activator was programmed with a single operational mode as specified by the customer With V2 multiple modes are programmed into each Activator Inform the factory of the mode you wish to have activated The user can also change the mode in the field Once the operational mode is set normally done at the factory setting up the unit for use is accomplished by setting rotary switches on the fro
10. al PM 14 99005V2 06rA Page 7 of 15 5 Locate the MODE CHART in the manual Once you have determined what mode you would like rotate the TIME SET rotary switch to the mode position you desire Then remove the shorting jumper on J5 from position B and place it on position A The Power LED should now be on solid The unit has saved this new mode setting in its non volatile storage memory and will return to that mode in the event of a loss amp restore of power O Ul RELAY OPTION Figure 3 Jumper Locations Changing The Relay Jumper J4 Jumper J4 is only used when the user wants to use the unit in dual relay modes If the unit is used in any of the single relay modes the jumper should be in position A When in any of the dual relay modes it should be placed into position B The following modes are used when in position A 0 1 2 3 4 5 6 7 11 12 13 While in the other modes 8 9 10 you should move the shorting jumper to position B You may now close the lid and fasten it down Programming is now complete Setting switches for DTMF code Radio Channel Select and Timer See Figure 4 Setting DTMF code To set the DTMF code start at the leftmost of the DTMF Digit Set switches and adjust each switch to the corresponding position The code may be up to six digits in length If the code is to be shorter set the switch after the last digit to D For setting the code
11. e mode of the Activator can be changed in the field See Section Specifications for a description of each mode and how to incorporate your choice of mode into the part number See Section V Service amp Ordering for instructions for specifying your Activator s configuration b Applications The Radio DTMF Activator provides radio controlled relay contacts for convenient control of gates switches and other equipment Note that it does not provide an answer back so it is recommended that it be used in situations where the user has visual or other feedback to determine that the desired actions have been initiated Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 3 of 15 era LIVLNOD MIVAa 133H LIVLNOD LIVLNOD 1NOY3 _ bosoGosothod UUU aronanoaus INADH 19385 annvHo OIGVH Oust OonIaooaq SNIAI393H O Olave 19990909 O 9 S v dc L 138 11910 AN LO FIGURE 1 RACK MOUNTING RADIO DTMF ACTIVATOR Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 4 of 15 D SELECT RADIO RECEIVE FREQUENCIES
12. ection V Service amp Ordering for instructions for specifying your Activator s configuration lil INSTALLATION SET UP amp ADJUSTMENTS Physical Installation The Radio DTMF Activator is available in two mounting versions The signal rack mounting version mounts in 2 rack spaces using Ya mounting hardware The wall mounting version mounts on a flat surface using 4 fasteners up to Ya diameter Electrical Installation WARNING THE RADIO DTMF ACTIVATOR HAS BEEN DESIGNED TO PROVIDE 2 000 VAC ELECTRICAL ISOLATION BETWEEN THE POWER TERMINALS AND THE CASE IF AN ANTENNA WITH EARTH GROUNDED SHIELD IS ATTACHED TO IT THIS WILL CAUSE THE POWER SUPPLY RETURN TO BE EARTH GROUNDED USE OF AN ISOLATION POWER SUPPLY IS RECOMMENDED WHERE THIS IS A PROBLEM Changing the Operational Mode Before installing your Activator ensure it is in the appropriate Operational Mode see Mode list in Section II Specifications above To change the operational mode of the DTMF activator follow these steps 1 Remove power to unit 2 Remove the front cover to gain access to the circuit board Locate J5 and place the shorting jumper on position B See Figure 3 3 Rotate ALL the rotary switches on the front of the unit to the 0 position 4 Apply power to unit you should now see the Power LED flashing If not check the above steps Radio DTMF Activator Installation Operation amp Service Manu
13. git Note about relay contact terminology The following terminology applies to the relay contacts of the Radio DTMF Activator Front Contact Contact Heel Back Contact Normally Open Contact open unless the relay is energized Contact Arm Normally Closed Contact closed unless the relay is energized Operational Modes The Activator has 14 modes built in and accessible to the user These are 0 Code toggles relay I E enter code to turn relay on enter code again to turn relay off Timer setting irrelevant 1 Code alone trips relay Timer 1 second per increment 2 Code alone trips relay Timer 10 seconds per increment 3 Code alone trips relay Timer 1 minute per increment 4 Code then to turn relay on or Code then to turn relay off There is no timer setting 5 Code then to turn relay on or Code then to turn relay off Timer 1 sec per increment 6 Code then to turn relay on or Code then to turn relay off Timer 10 sec per increment 7 Code then to turn relay on or Code then to turn relay off Timer 1 minute per increment 8 Code then enables relay 1 Code then enables relay 2 Timer 1 sec per increment 9 Code then enables relay 1 Code then enables relay 2 Timer 10 sec per increment Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 6 of
14. here may be a charge for this service The user may also reprogram the radio If you choose to do the reprogramming verify that you have the proper software and cables for the model radio in your Activator The software and cables can be purchased directly from Ritron Radio in Carmel IN 800 872 1872 Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 9 of 15 FIGURE 4 FRONT PANEL CLOSE UP Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 10 of 15 Note on Radio Channel Numbering The channels are numbered differently in the radio and on the Radio DTMF Activator front panel The following chart illustrates Radio Channel 1 2 Activator Channel 7 6 5 4 3 2 1 0 wo IN al O N 00 FIGURE 5 INSIDE OF RADIO DTMF ACTIVATOR IV OPERATION When the unit is installed powered up and sitting idle the POWER LED will be illuminated When a radio signal on the frequency selected is received by the radio receiver the RADIO RECEIVING LED is also illuminated Whenever the DTMF decoder detects a DTMF digit regardless if it is part of the selected code the DECODING LED will be illuminated Whenever the relay is activated the TIMER LED is illuminated this applies to models with the timed relay as well as to models with the relay control Radio DTMF Activator Installation Operation amp Service Manual PM 1
15. l Mode choose one of Operational Modes 0 13 Z Radio D Ritron DTX Plus VHF E Ritron DTX Plus UHF Example 14 99005V2 B6D is an Activator wall mounting operational mode 6 with a Ritron DTX Plus VHF radio Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 13 of 15 87 62008 Cable to enable programming radio without removing radio from enclosure Programming software and cable from radio manufacturer is still required Radio programming software and cable is available from Ritron Ritron can be contacted at 800 872 1872 VI DRAWINGS Following is a drawing of the Programming Cable p n 87 62008 Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 14 of 15 D 80079 48 TIVO DOUd YOLVAILOV aroma aus caza bas SINA LSAS TOLLNO9 ANY NOILVOINAWWOD NVdWO 1190W ANAVI OST HSINII CMO MONA NMVUU STVAOUddV MNIUHSLVSH sii L PLELZI WONG SAGE SNid INO SI 9 SNId qasn a a fe O mota NASO PERRO NMOMA dis Lr gq NAO el 5 WO o oo o o 0 59 O O ES S09 0000000 95 L an u r J F n 9 o oO d NMOWa NMONA zr ada MOTA pf La O c dH LS N ry file f T VTA NI AITITA NIVULS Ln ITITI NIVILIS cga TIYWIA NA NAN Naa o T ds PTT c So I pp o NMOY o x or 91 2892 FVHATIV IM fr O 09 GN 9SLW49 P
16. l mode in the original style of Activator e n Modes 11 and 12 the relay will energize when the proper DTMF code is detected followed by a and numbers xyz In Mode 11 xyz indicates the number of seconds the relay will remain activated and in Mode 12 xyz indicates the number of minutes the relay will remain activated OPERATING UNITS USING COMBINATION ON OFF amp TIMED MODES Modes 5 6 7 and 13 In Modes 5 6 and 7 the relay is activated then the proper DTMF code followed by a is detected The relay is deenergized when either of the following conditions is met e The timer times out e The proper DTMF code followed by a is detected or in mode 13 Resetting the Timer Before It Times Out Transmit the DTMF digits with a 2 way radio on the selected frequency The relay will become energized and will remain energized for the amount of time set by the TIME SET switch To hold the relay energized for a longer amount of time re transmit the DTMF digits before the relay times out Once the digits have been detected the timer will reset to the full time If the time is set for 80 seconds and the DTMF digits are resent and detected after 40 seconds the timer will reset and the relay will remain energized for a total of 120 seconds This procedure can be repeated as necessary Radio DTMF Activator Installation Operation amp Service Manual PM 14 99005V2 06rA Page 12 of 15 RELAYS FIGURE 6
17. nt panel and LEDs enable quick and easy status verification Multiple operational modes programmed into each Activator enable it to be used for many applications However if your installation requires an operational mode different from what is normally provided please contact the factory for availability Please feel free to send us your comments on your experience with the Radio DTMF Activator MANUAL SECTIONS I INTRODUCTION DESCRIPTION 8 APPLICATIONS 3 IL SPECIFICATION Sound 6 III INSTALLATION SET UP amp ADJUSTMENTS 7 IV OPERATION serre nere e ee sarei eee ere eee irene 11 V SERVICE amp ORDERING coxis 12 VI DRAWINGS akak aide cts ceive ce ch cased SING cect civ cist ceive cu ia 13 Revisions Rev 01 Original Publication Rev 02 Added 3 operational mode Rev 03 Added explanation of DTMF codes and further clarified operation of Momentary Contact operational mode Added further notes in Antenna section Rev 04 New circuit board incorporating additional modes implemented This revision includes changing the Model Number to 19 99005V2 x This version started production in January of 2006 NOTE For pre V2 Activators use Rev 03 Manual or earlier as appropriate Rev 05 Added note on cover page regarding proper connection of power leads Rev 06 Added Mode 13 updates