Home

Manual - Lightronics

image

Contents

1. 12 60 12 60 10 1806 531 3 8 20 481 145 6 14 30 220 75 10 20 www lightronic com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 LIGHTRONICS Tae FXLD336ZM31 LED FIXTURE Version 0 1 OWNERS MANUAL 02 21 2012 MENU NAVIGATION MENU Display flashes A U U Up Down set DMX address 001 255 DMX ADDRESS Enter save and activate URIDOWN a JAG Display flashes ZOOM l ol L Up Down set zoom level 000 255 Enter save and activate RUN Display Flashes PROGRAM Up Down select program 00 13 Enter save and activate Display Flashes PROGRAM Up Down set speed 00 99 00 Fast SPEED Enter save and activate Display Flashes PROGRAM a FADE RATE Up Down set fade rate 00 99 00 Fast Enter save and activate SOUND Cc H ENTER Display Flashes ENTER SEQUENCE JALI Enter save and activate UP DOWN i ENTER LAVE L CIl ENTER Display flashes a JL MILI Enter save and activate DOWN gt k Fade rate not used for all programs www lightronic com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 LIGHTRONIcS mi M ARRANTY This product is warranted for a period of TWO YEARS from the date of purchase against defects in materials and workmanship This warranty is subject to the following restrictions and conditions A If service is required you may be asked to provide proof of purchase from an authorized Ligh
2. VA 23454 20100211 www lightronic com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588
3. is the value range 000 is 12 and 255 is 60 AUTO PROGRAM OPERATION Auto Program operation includes 14 00 13 colors and patterns which can be run There are also speed and fade sub functions to control the selected program Use the Pr menu to select a program Use the Sp and FA menus to control the speed and fade rates SOUND OPERATION Use the SOUA menu to invoke the Sound Color option The unit will sequence through a series of colors in sync with music base notes MASTER SLAVE OPERATION Connect the units together using DMX cables Set all the units to be slaved to DMX address 001 Set the master unit to any auto operation option The slave units will sync to the masters operation MAINTENANCE AND REPAIR TROUBLESHOOTING Check that you have power applied to the unit Check the DMX control cable Check the address settings of the unit and the controller 757 486 3588 LIGHTRONICS Page 3of 5 FXLD336ZM3I LED FIXTURE Version 0 1 OWNERS MANUAL 02 21 2012 REPAIR CAUTION DO NOT OPEN UNIT RISK OF ELECTRIC SHOCK RISK OF FIRE Internal service on the unit by other than Lightronics authorized agents will void the warranty If service is required contact the dealer from whom you purchased the item or contact the Lightronics Service Department 509 Central Drive Virginia Beach VA 23454 Tel 757 486 3588 PHOTOMETRIC CHARACTERISTICS Distance llluminance Beam Diam ft Lux ft
4. LIGHTRONICS Version 0 1 FEATURES AND SPECIFICATIONS LEDS 36 Three Watt LEDs RGB 3 in 1 Beam angle 12 60 motorized zoom Control system DMX 512 DMX channels 6 DMX connectors 3 pin XLR Voltage 90 264 VAC 50 60Hz Max power consumption 140 Watts Size 10 7 8 D x 8 3 4 W x 8 3 4 H Body material Cast Aluminim IP Rating IP20 Body color black Weight 12 1 lbs DESCRIPTION The FXLD336ZM3I is a PAR style RGB LED lighting fixture with zoom capability It is suitable for stage disco night club and other artistic applications It has several stand alone control modes a master slave mode and can operate via a DMX 512 external signal A double yoke enables it to be operated in several positions INSTALLATION LOCATION The FXLD336ZM3I is intended for INDOOR USE ONLY and is rated IP20 Locate the unit in a well ventilated area away from moisture and heat Holes are provided on the yokes to install a lighting bar pipe clamp A safety cable should also be used Do not block any vent holes POWER CONNECTIONS The FXLD336ZM3I has a line cord for connection to a 120 VAC 15 Amp 60Hz grounded service CAUTION RISK OF ELECTRIC SHOCK A The safety ground pin on the power cord must be used DMX CONNECTIONS A system using DMX control should be connected as a chain of devices In other words the control signal cable should proceed from the controller to the first www lightronic com Lightronic
5. s Inc 509 Central Drive Virginia Beach Va 234354 Page 1of 5 FXLD336ZM3I LED FIXTURE OWNERS MANUAL 02 21 2012 receiving device and then to others in a continuous daisy chain fashion The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device pack DMX CONNECTOR PIN ASSIGNMENTS There are two different connectors which can be used for DMX control They are both XLR type connectors Some units use 3 pin connectors Others use 5 pin connectors The FXLD336ZM3I receives a DMX signal on the 3 pin MALE connector on the back of the unit The 3 pin FEMALE connector is used to connect the next DMX device on the control chain If your console uses a 5 pin connector you can make up an adapter cable to accommodate this The table below shows the pin assignments for BOTH the 3 pin and 5 pin connectors IN SIGNAL NAME DMX COMMON DMX DATA DMX DATA NOT USED NOT USED 0 B O NN 757 486 3588 LIGHTRONICS Page 2of 5 FXLD336ZM3I LED FIXTURE Version 0 1 DMX TERMINATION A DMX chain should be terminated at the last receiving device on the chain This is done by installing a commonly available 1 4 Watt 120 Ohm resistor across the DATA and DATA wires at the last device If you have only a few fixtures ver
6. tronics dealer B This warranty is valid only for the original purchaser of the unit C This warranty does not apply to damage resulting from abuse misuse accidents shipping and repairs or modifications by anyone other than an authorized Lightronics service representative D This warranty is void if the serial number is removed altered or defaced E This warranty does not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied Lightronics is not responsible for supplying new equipment in accordance with any earlier specifications G This warranty is the only warranty either expressed implied or statutory upon which the equipment is purchased No representatives dealers or any of their agents are authorized to make any warranties guarantees or representations other than expressly stated herein H This warranty does not cover the cost of shipping products to or from Lightronics for service I Lightronics Inc reserves the right to make changes as deemed necessary to this warranty without prior notification Lightronics Inc 509 Central Drive Virginia Beach
7. y close together and a very short run to the controller then you may be able to operate without the terminator OPERATION Operating options are set using the LED display and 4 buttons MENU ENTER UP DOWN on the rear of the fixture FXLD336ZM3I REAR VIEW Push MENU to access the operating options Then use UP and DOWN to scroll through the available choices When you reach the option you want to set or change push ENTER Now you can view the current setting for the option and or change it Push ENTER to save your changes Push MENU to return to the current option display See the MENU NAVIGATION diagram for additional details There are 4 main operation modes DMX Auto Program Sound Master Slave There is also a provision to control the zoom function DMX OPERATION Use the ADDR menu to set the starting address of the unit You can set the starting address of the unit with the UP and DOWN buttons www lightronic com Lightronics Inc OWNERS MANUAL 509 Central Drive Virginia Beach Va 234354 02 21 2012 The fixture uses six DMX channels with allocations as follows CHANNEL 1 0 255 Master Level CHANNEL 2 0 255 Red Level 255 max CHANNEL 3 0 255 Green Level 255 max CHANNEL 4 0 255 Blue Llevel 255 max CHANNEL 5 0 255 Strobe Effects CHANNEL 6 12 60 Zoom Control ZOOM CONTROL The fixture can zoom its beam diameter between 12 and 60 degrees Use the FoCS menu to control it 000 255

Download Pdf Manuals

image

Related Search

Related Contents

APS CareConnection® Web Application User`s Manual  5046KB - Dynabook  ASR-E Product User`s Manual Firmware 5.00 and up Last Update  Electrodo de nivel NRG 211-1  

Copyright © All rights reserved.
Failed to retrieve file