1. Eloma Combi Steamer Multimax B Genius T Gas units Genius T 6 11 Genius T 10 11 Genius T 20 11 Genius T 12 21 Genius T 20 21 Installation and Technical Connections Dear Customer These installation instructions contain details about setting installing and adjusting the combi steamers Multimax B Genius T 6 11 10 11 20 11 12 21 and 20 21 Gas Pass on these instructions to the gas fitters and ensure that they are precisely followed when the combi steamer is being installed otherwise functional faults may occur Please read the installation and operating instructions in full before starting up the appliance and make sure to pay particular attention to the safety information Attention The named standards are valid for Germany in all other countries follow the local standards and valid instructions Damages based on installation not complying with the directives given hereunder are not covered by warranty terms Check for any transport damage Should there any signs of transport damage inform your dealer freight forwarder immediately For information and tips please contact Eloma GmbH Innovative Koch amp Backtechnik 82216 Maisach Germany Otto Hahn Str 10 Tel 49 0 8141 395 0 Fax 49 0 8141 395 130 For our cooking forum and user tips visit our website at www eloma com User hotline 49 0 35023 63887 Service You can reach us practically around the clock 7 days a week 365 days a year Your servi
2. Housing dimensions and technical connections of models Multimax B are identical 40 55 1030 6 18 137 Lga mot shown 34 65 880 Blogs 2009 76 38 1940 Lga Lrg Lzu A EWk TWk EZ PE X R KS EK Ga amp J 4 P Fin n T AE Flow safeguard Exhaust pipe Air inlet Drain 1 97 50mm Softened water G3 4 A Tap raw water G3 4 A Pover supplay Potential equalisation Adjustable height range 0 39 10mm Connection cleaner Connection rinse agent Serial interface Gas supply 3 4 Technical amendments are reserved 20 25 99 660 PEBL 560 19 697 80b Dimensioned sketch Combi Steamer Genius T Gas 12 21 Housing dimensions and technical connections of models Multimax B are identical 5156 39 2 017 was 2 wen E es 18 157 EM HrU ina LT Yd JAL 9 LE ni ABD Ee a EM 0 t 4 LIT 50 a AA zz 6p 3 145 58 6 1145 A i I s ah ASA B I e ur u en ja 158 40 5177 13 E 3187 605 dn 15 06 382 ETT 20 728 790 ST M0 217 130 A TY TM amm us 3r i il Lga Flow safeguard Lrg Exhaust pipe la Lzu Air inlet x A Drain 1 97 50mm z EWk Softened water G3 4 A TWk Tap raw water G3 4 A EZ Pover supplay PE Potential equalisation X Adjustable height range 0 39 10mm R Connection cleaner KS Connection rinse agent EK Serial interface Ga Gas supply 3 4 Technical amendments are reserved 21 c 130 1309 33 44
3. 190 i 140 18 12 460 Dimensioned sketch Combi Steamer Genius T Gas 20 21 Housing dimensions and technical connections of models Multimax B are identical SL 1230 10 77 E73 dig 157 t I ha T n ino E EEC rU eme 605 44 89 1140 La 5 22 Ac Ap 10504 4 92 125 2 02 ra na Loa xj 315 B cra rep Lzu q E 3 u od LE z 126 E38 1 23 BHO i 43 90 Bal Lga Flow safeguard Lrg Exhaust pipe Lzu Air inlet A Drain 1 97 50 mm EWk Softened water G3 4 A TWk Tap raw water G3 4 A EZ Pover supplay PE Potential equalisation X Adjustable height range 0 39 10mm R Connection cleaner KS Connection rinse agent EK Serial interface Ga Gas supply 3 4 Technical amendments are reserved Notes 23 Notes 24 Englisch Art Nr ins EL0791342 mb gt g 2v8 enus eloma Eloma GmbH Innovative Koch und Backtechnik Otto Hahn Stra e 10 82216 Maisach Germany A Phone 49 0 8141 395 0 Fax 49 0 8141 395 130 info eloma com www eloma com E oe a or
4. a dangerous situation arises or if you smell gas Shut off the gas supply immediately Do not touch any electrical switching elements Make sure the area is well ventilated Avoid creating naked flames or sparks Use an external telephone and inform the relevant gas supplier fire service as well as customer service Only authorised customer service personnel may open the side wall and carry out repairs and maintenance work Risk of injury Installation Please refer to the installation instructions for precise information on how to install the appliance Only authorised customer service personnel may install appliances put them into operation and perform maintenance work on them Appliance defects Ifthe glass part of the door is damaged the appliance must not be started up Contact customer service f malfunctions occur disconnect the appliance from the mains and close the water shut off valve Contact customer service IN Notes on maintenance The maintenance must be carried out at least once every year in accordance with national applicable standards and regulations We recommend that you agree a maintenance contract for this purpose Ifthe appliance is not going to be used for a prolonged period turn it off disconnect it from the mains and close the water tap A Hand shower with automatic pull back Pull the hand shower out until you hear it click this means that it is locked
5. down the condensed water 3 3 Diagram of connection Drain Tap raw water Softened water Power supply Gas supply Connection cleaner Connection rinse Potential equalisation Adjustment 10 mm OS Oe G9 i ce 3 4 Water connection for fresh water with water softener 3 5 Water connection for Osmosis Softened water and fresh water 3 6 Water connection for Osmosis Softened water Sofened water i Fresh water 3 7 3 8 3 9 Water pressure Min 200 kPa 2 bar Max 600 kPa 6 bar Max flow rate Typ 1 631 10 11 1221 20 11 2021 Water hardness conversion table 1 d 0 18 mmol l ISO unit 1 d 10 CaO 1 d 1 79 fH France 1 d 1 25 eH UK 1 d 7 14 H USSR 1 d 1 04 aH USA Autoclean Optional Equipment Please use only Eloma MULTI CLEAN spezial detergent and Eloma MULTI CLEAN Klarspuler rinse aid for cleaning your Eloma equipment The Eloma distributed detergents and rinse aids contain special components with exact measurements that are specifically synchronized and tested for optimal results with Eloma machines Other cleaning products can possibly cause irreparable rust damages in the cooking chamber as well as damage pumps and seals Eloma GmbH cannot assume liability for any damages resulting from the use of alternative products This will void the Eloma warranty Connection Refer to the dimensioned sketch for connections of cleani
6. in charge and record the approved construction e Appliances of Type A are defined as units that can be operated without exhaust gas evacuation installations A 3 with blower before the burner e Appliances of Type B are defined as units that must be operated with exhaust gas evacuation installations B13 B23 with blower before the burner Set up under extractor hood Exhaust air evacuation system in accordance with DVGW DVGW German technical scientific association on gas and water work sheet G 634 Install in accordance with local prescriptions Gas appliances in accordance with type B23 which are set up under an extractor hood do not need a flow safeguard The pipe must end under the flame protection filter with a clearance of 1 25 to 2 times its pipe diameter e The filters of the extractor hood must be capable to withstand a waste gas temperature of 500 C 932 F Use a flame protection filter e lf the exhaust gas of gas appliances type B23 is extracted by a hood precautions have to be taken to ensure that the gas supply to the burner is not released unless an extraction is guaranteed 7 3 Connection to exhaust gas systems natural lift or forced ventilation Connections to chimneys with flow safeguard must be in accordance with the German Standard DIN 18160 section 1 Connections to an exhaust gas evacuation system must be according to DVGW regulations work sheet G 660 Respectively observe vigorously the loca
7. oven to the water supply wash out clean the building pipe system All appliances are equipped as standard with 2 water connections for soft water and hard water Both connections are under the indication plate and both must be connected The appliance must be connected to the water supply using a flexible hose that conforms to EN 61770 resp IEC 61770 with a 3 4 screw connection The water supply hose must fulfil the local or standard hygiene requirements for hoses in drinking water systems Ensure there is sufficient pipe length left minimum 50cm so as to allow for easy access when servicing the appliance Install an easily accessible water shut off valve for every unit None corrosive connections couplings must be used at all times between the water treatment equipment and the Combi Steamer failure to do so could cause rust to form within the unit None compliance would be a breach of the warranty conditions 7 In coming water supply quality Check the water quality and water hardness with your local water supply company before commencing with installation The Incoming water quality should not exceed the following limits With water it is necessary to know about the ingredients and their effects Total hardness lt 3 dH pH value 7 0 bis 8 5 conductivity lt 90 uS cm CI Max 60 mg l SO Max 100 mg l SiO Max 10 mg l Fe Max 0 05 mg l Mn Max 0 05 mg l Cu Max 0 05 mg l Cl Max 0
8. the appliance it is essential that operating staff are given training and health and safety briefings on a regular basis fthe machine is set up outside it must be ensured that it is adequately protected from rain thunder storms and lightening It must be set up on a solid foundation to ensure stability It must also be ensured that the machine is only accessible for qualified personnel The appliance must not be operated By children or persons with impaired physical sensory or mental abilities or by persons who do not have the requisite experience and or knowledge unless they are being supervised by a person who is responsible for their safety or are receiving instructions in how to use the appliance from this person At an ambient temperature of lt 4 C In toxic atmospheres or atmospheres where there is a risk of explosion With food containing highly flammable ingredients e g alcohol Gas appliances The gas outlet pipe and its cover can reach high temperatures on gas appliances Waste gas and hot sheet metal parts can cause burns Do not place any flammable materials over the appliance lf the appliance has been installed under a hood this must be turned on during cooking When connecting to a chimney with flow protection the exhaust line must be cleaned on a regular basis in accordance with country specific regulations Only operate gas combi steamers when wind conditions are calm What to do if
9. 10 mg l Soft water connection If the total water hardness is 2 3 dH at least one hydrogen ion exchanger must be connected upstream from the soft water connection on the machine For our units approved filter systems are partial demineralisation filters with integrated particle and activated carbon filtration as well as a bypass Among others Brita offers adequate filter systems Sodium ion exchangers as normally used for dishwashers are not permitted for our machines The glass window can become dull and stainless steel components in the cooking chamber could be irreparably damaged Systems with silicate metering must not be used They can cause malfunctions and scaling in the cooking chamber Systems that operate with electromagnetic fields do not protect against lime scale in this type of machine If the total water hardness is 3 dH but the water contains impurities such as sand iron particles or suspended particles a 5 15 um fine filter must be installed upstream from the soft water connection on the machine If the water is chlorinated Cl in excess of 0 1 mg l corresponding to 0 1 ppm an activated carbon filter must be additionally installed upstream from the soft water connection on the machine Activated carbon filters may also be an integral part of fine filters Hard water connection If the water contains impurities such as sand iron particles or suspended particles a 5 15 um fine filter must be installe
10. U h 41000 68000 136000 4 119000 239000 amp Connectedload kW 1 1 5 1 5 The table models units are supplied with a connecting cable length 2 m In case this cable has to be replaced for whatever reason use a cable type HO7RN F according to German VDE standards Next to the appliance an all pole electric circuit breaker with a contact opening of at least 3mm has to be provided for on site The appliance must be incorporated into the potential equalisation system ground In case a plug is mounted the plug device must be accessible after setting up Please note gt Do not fit a mains plug to the mains cable Securely connect the mains cable to prevent phase distortion gt Connect the phase to the brown cable L otherwise failures in the gas system will occur In such case the symbol failure gas system would be displayed 7 2 Installation instructions Setting up possibilities The DVGW DVGW German technical scientific association on gas and water and the Technical regulations for liquid gas installations TRGI G 600 give systematic information about the different types of gas appliances their exhaust gas evacuation and their combustion air supply Consequently do observe vigorously the local regulations prescriptions and standards of your country for the installation of catering gas appliances Prior to setting up discuss the construction of the exhaust gas system with the local chimney sweep
11. and cleaning Observe the load capacity of the floor Is the installation location accessible regarding the appliances measurements 423 kg 378 kg 569 kg Floor models need at least 500 mm clearance to the left side to ensure access for service We recommend 800 mm it is then possible to park the trolley on this side For maintenance and easy access to the unit for service operations use flexible water and electric connections The appliance should be removable approximately 1 meter from its standard position 2 3 2 4 2 5 2 6 Hints for setting up The floor underneath the appliance must be plane to ensure a smooth driving in of the trolley roll in pan rack The trolley must be pane in the unit Fix the appliance after adjusting the level and angle so that the oven can t shift anymore There should be a minimum distance of 15 5 mm between the trolley and the top edge of the oven cavity bottom The trolley must never touch the door gasket and must be level with the appliance Door gasket Spacer 15mm 5 Removal of protecting film from the floor models Prior to starting the machine the protective film must be removed from side back and cover surfaces Use special cleaner to clean to perfection Do not operate the oven with the adhesive film Noise level The emission value of the noise level is less than 70 dB A Exhaust air A built in cooli
12. ce hotline 49 0 35023 63888 For information on liability for material defects and warranty conditions please consult our general terms and conditions of business T amp C Eloma GmbH D 82216 Maisach Installer Installation instructions Combi Steamer Multimax B Genius T Gas 6 11 10 11 20 11 12 21 20 21 Table of contents AA o 4 2 eldest iplc icio er seele riesen 6 2 1 installation Jas UU CONS 3 ssoesia sep retrato Ai 6 22 Hints TOP ico ojo me 7 2 3 Removal of protecting film from the floor MOAEIS oooocccccconcnnncccocnnccnnoncncononenonononcononnnnos 7 2 4 INOISCICVE ass T 25 0 mc mE tinta N T 2 6 Heat emission into the Aarea ooocoocccocccoccconcconoconoocnconnnnnnonnnonnnonnonononononannnnnnnnnonnnnaninaninaninnnnns T Oe A O e tet cun LS T 3 1 N coming Water SUDDIY QUA 8 3 2 Hard water cold water connection cccoccccccccccocnncccnnncoonnnonnnnnnnnnnonnnononnnnonnnonnnnnnonnnononnnennnnnnns 9 9 Diagram olConnNeCUON esarete 9 3 4 Water connection for fresh water with water SOftener cocoooccccccncccoccnnccnncconnncnnnnnnonononanonons 9 3 5 Water connection for Osmosis Softened water and fresh water sseusssus 9 3 6 Water connection for Osmosis Softened Water ccccoccnccnnnccccnnconcncconnnnoncnononononnnncnncnonanonnns 9 33 NS A O n al ae en 10 3 0 Max OWAE tas ia 10 3 9 Water hardness conversion table cooococoncc
13. d upstream from the hard water connection of the machine If the water is chlorinated Cl in excess of 0 1 mg l corresponding to 0 1 ppm an activated carbon filter must be additionally installed upstream from the hard water connection on the machine Activated carbon filters may also be an integral part of fine filters Special requirements If the chloride CI concentration is in excess of 60 mg l corresponding to 60 ppm and or the concentration of silicate SiO4 is 2 10 mg l there is a greater risk of corrosion Thus the water for the entire water supply of the device must be treated with a reversed osmosis system Make sure that the reference value of 10 uS cm is maintained as totally pure water is too aggressive and would cause severe damages Reverse osmosis systems can be an alternative to full and or partial demineralisation systems Reverse osmosis systems remove almost all water hardening substances and non hardening minerals from the water If a combination of filters and water treatment system is installed the following components must be installed in the specified order sediment filter hydrogen ion exchanger with activated carbon filter shut off valve Regular maintenance and cartridge replacement on all forms of water treatment is vitally important Damages to Eloma machines resulting from neglect of maintenance will void any warranty claims 3 2 Hard water cold water connection Cold water connection for cooling
14. feguard Exhaust pipe Air inlet Drain Y 1 97 50 mm Softened water G3 4 A Tap raw water G3 4 A Pover supplay Potential equalisation Adjustable height range 0 39 10mm Connection cleaner Connection rinse agent Serial interface Gas supply 1 2 For left hand hinged units see their dimensioned sketches Technical amendments are reserved 18 20 08 310 18 147 460 17 32 443 16 34 453 Dimensioned sketch Combi Steamer Genius T Gas 10 11 Housing dimensions and technical connections of models Multimax B are identical 36 15 923 we 140 4 SF 115 nPE 29 33 645 3 31 140 34 10 1120 ai 30 91 785 iia d EE 27 87 200 Jd oye 110 39 R 197 50 EE T wi i a E dba in B ER E a PEL EE T 1 18 30 71 7 B 4 6 45 164 Rir SS e197 50 Ing 2 95 75 T Lga _ AS Lrg Tul MAD m dl E an KCS n EZ mr A UEM ze a m Sie 130 19 30 490 Lga Flow safeguard Lrg Exhaust pipe Lzu Air inlet A Drain 1 97 50 mm EWk Softened water G3 4 A TWk Tap raw water G3 4 A EZ Pover supplay PE Potential equalisation X Adjustable height range 0 39 10mm R Connection cleaner KS Connection rinse agent EK Serial interface Ga Gas supply 1 2 For left hand hinged units see their dimensioned sketches Technical amendments are reserved 1 3407 40 12 29 356 Dimensioned sketch Combi Steamer Genius T Gas 20 11
15. in the correct position for operation To retract the hose pull it out until it stops making a clicking noise The hose will retract automatically Water will only flow when the hose is locked in the correct position for operation You should only ever allow the shower head to slide back into its resting position slowly Before turning on Ifthe combi steamer has been transported at outside temperatures of lt 4 C the appliance s safety temperature limiter may have been triggered This must be reset by a qualified electrician Lock the air baffle in place Never reach behind the air baffle during operation and never attempt to stop fans manually Lock the rack or mobile tray rack in place correctly 2 Equipment set up A Transport of units Use elevating truck or fork lift truck for transport Transport only on pallets Observe door width and door height when transporting the units X Typ 1 64i 4041 2024 223 1 204 B mm 1050 4050 1100 1520 1520 L X d Damaged equipment may not be installed 2 1 Installation instructions To prevent injury always lift the appliance off the pallet with the aid of a second person risk of crushing Follow the local regulations and observe the instructions for the installation of kitchen and shop equipment Remove all cartons packing materials documents from the interior cabinet No heat or steam sources may be ins
16. l regulations prescriptions and standards _ Flow safeguard 14 The gas fitter will make the necessary assessment of the room size and ventilation Prior to connection to an exhaust gas evacuation system send for the area master chimney sweep When connecting to an exhaust gas evacuation it is necessary to have the flow safeguard installed Pay attention to the exhaust gas temperatures All parts pipes fans which come into contact with hot exhaust gas must be heat resistant Connect mains cable e Connection conversion and repair of gas consuming equipment in catering kitchens and the remedying of faults in equipment of this type may only be carried out by the gas supply company a skilled representative of the manufacturer with DVGW or any local certificate a contract installation company or a sales organisation authorised by a liquid gas distribution company e Before making any connections inform the responsible gas supply company Observe the Technical regulations for gas installations DVGW TRGI DVGW German technical scientific association on gas and water and refer to work sheets G 600 G 628 G 634 G 660 G 670 and the Technical regulations for liquid gas TRGI Respectively observe the technical regulations and instruction for gas installations of your country For USA Gas lines and connections should be sized according to the charts referenced in NFPA 54 or the local authority having ju
17. ling the appliance incorrectly making incorrect settings on it or modifying it can lead to damage injury or even death Read the installation and operating instructions for the combi steamer through carefully before starting it up Use for intended purpose Eloma combi steamers may only be used for preparing food in commercial kitchens Every other usage is against definition and therefore dangerous Method of operation The combi steamer enables you to prepare food goods using the best possible cooking chamber environment This means the ability to adjust temperature and humidity levels exactly as required for each type of food good Atthe same time the required cooking method can be selected using the Scout feature on the operating panel The cooking chamber temperature can be set as required to between 30 C and 300 C and the humidity level to between 0 and 100 The large number of setting options available enables a wide range of cooking methods to be used The Genius is ideal for steaming stewing roasting baking grilling gratinating poaching regenerating defrosting and much more Operation Keep this manual in a place where it can be accessed by all users of the appliance at any time The combi steamer must only be operated By trained staff For its intended purpose as outlined in the operating instructions and whilst in perfect working order To prevent the risk of accidents or damage to
18. ly e The failure indicator responds several times in the case of long gas supply lines e tis therefore necessary to restart several times 16 10 Technical Data Technical Dat MB Genius T MB Genius T MB Genius T MB Genius T MB Genius T 20 21 Gas Gas Gas Gas Gas High grade steel stainless Outer dimensions Width 925 mm 1030 mm 1310 mm 1310 mm Depth 805 mm 880 mm 1090 mm 1090 mm Height 1120 mm 1940 mm 1495 mm 1935 mm Temperature 30 300 C range cooking chamber Number of levels 6 x GN 1 1 10 x GN 1 1 20 x GN 1 1 12 x GN 2 1 20 x GN 2 1 Spacing between levels 67 mm Gas data Gas consumption Connected load based on standard conditions of gas max consumption on nominal heat load unit size 6 11 10 11 20 11 20 21 20 21 heat load gas kW 12 20 40 35 70 gas type Required calorific value m3 h flow MJ m3 pressure De eb 08 310 460 18 11 Dimensioned sketch Combi Steamer Genius T Gas 6 11 Housing dimensions and technical connections of models Multimax B are identical 36 45 925 3 51 140 24 93 115 91 97 25 35 645 33 08 840 34 85 885 2 76 70 30 91 785 3 94 100 Lga Lrg Lzu A EWk TWk EZ PE X R KS EK Ga 17 92 445 16 34 415 13 78 350 12 60 320 158 40 31 7 804 6 45 164 mm el 33 M 30 All Lzu WI A 41 324 Py m A RKS ly 5 12 130 60 19 30 490 Flow sa
19. ng and rinse agent The label on the oven indicates where the chemicals have to be connected Reiniger Klarspuler Cleaner Rinse agent Nettoyant Rince eclat Use the supplied clamps to connect the hoses to the oven Red for the cleaner and blue for the rinse agent Handling of cleaner and rinse agent Observe the directions of the manufacturer and wear suitable protective clothing gloves and glasses Canisters must be positioned below the bottom edge of the combi steamer They must never be positioned above this Maximum vertical range from canister to connection 1 50 m Maximum hose length 10 m Remove the lids of the two canisters cleaner and rinse agent and screw the screw cap with hose to the respective canister Red for the cleaner and blue for the rinse agent Start the installation program Autoclean Check if cleaner and rinse agent are sucked into the cooking chamber If necessary please repeat the Autoclean start up level Autoclean is ready for use To detailed data and function of Autoclean see operation manual of the combi steamer Drain connection Local water and regulation should be adhered Connect drain to the waste water system in accordance with the German standard DIN 1986 section 1 The appliance complies with the relevant regulations Drain and air vent pipe material must be steam temperature resistant Minimum diameter 50 mm preferably not lo
20. ng function cools down water and steam of condensation which runs down the drain It is therefore not necessary however recommended to install the appliance under a ventilation hood lf such a hood is installed its design and power rates should comply with the German VDI regulation 2052 Condensation hood option An optional condensation hood is available for Eloma combi steamers The condensation hood is controlled fully automatically via the combi steamer During the cooking process steam is condensed as it passes over air cooled plate condensers Observe the installation manual condensation hood for proper installation of the hood Heat emission into the area A O O Typ 6 11 10 11 20 11 12 21 20 21 Connecedioad KW 105 20 0 400 330 660 latent MJh 4 320 7 200 14 400 12 000 25200 P sensible MJ h 3 672 6 120 12 240 10 710 21 420 Water supply Local water and regulation should be adhered to at all times The appliance must be connected to the drinking water supply in accordance with DIN EN 1717 For UK the inlet supply shall be fed via fluid backflow prevention category three arrangements such as a double check valve Our entire range of Combi Steamers comply to the following water regulations WRAS and DVGW and can be connected to the drinking water supply without any other measures having to be put in place Non return valves are integrated within the appliance Before connecting the
21. nger than 1 m we recommend high temperature resistant pipes type HT PA I 1818 according to the German standard DIN 19560 It is not permitted to taper the cross section of the drain Slope of at least 5 is necessary Waste water temperature 80 C To fill the siphon give about 3 liters of clear water into the oven prior to any first start Fixed connection without trap EEE Combi Steamer ven DIPS Drain fannel rear view The Eloma GmbH bears no liability for any damages caused by a not proper installation 6 1 Electrical connection EZ und Potential equalisation PE Do not connect the unit to the mains if it has just been transported from a cold environment into a warm room Otherwise condensate may develop inside the combi steamer which may cause damages Wait for about two hours until the unit has reached room temperature Electrical connections must be carried out by an approved electrician in accordance with VDE regulations and regulations of the local electricity supply companies Pay attention to the data on the type plate for the electrical connections Electrical connection data gas units Ty 611 20 1221 20 21 _Heatloadgas kW 120 200 1400 0 2350 h 0700 Connected load kW 0 6 0 7 1 6 1 1 1 9 electric Voltage o 2390V1NACS0HZ 0 000 Fuse protection Amp 1x10 1x10 1x16 110 1x16 USA TYP 641 1041 2041 1221 2021 Power Gas BT
22. ocncconccccnccnnnononcconnoconononnnnnnnnnnonannonanenannnnons 10 4 Autoclean Optional EQUIP sn 10 Ds DEIN CONNOR rasa 11 6 Electrical connection EZ und Potential equalisation PE ccooccconnccccnccncncocnconcncnnncnnnonnnncnnnonos 12 6 1 Electrical connection data gas units ooccconncconnccncocnconcnnnnncnonncncnnncnnoncnnnnncnnoncnnnnnrnnnnrnnonanoss 12 Pe NsStallallomInsttuUcl ons 13 LA seting up possibilities usa eek ine el a 13 7 2 Setup under extractor hood es 13 7 3 Connection to exhaust gas systems natural lift or forced ventilation 14 8 KGonnecetmalnse ble ses 15 9 a a a a a aa 16 OPE CHIC AD A a a a UT EE 17 Dimensioned Rest Co er a des HH ee 18 Article No EL0791342 Explanation of symbols Version 2 8 07 2013 gt Activities to be carried out e Notes functional sequences Pictograms symbols used A Danger A Warning Immediate dangerous situation Possibly dangerous situation that can endanger severe injury that possibly can endanger severe or death or death Corrosive substances Risk of explosion Caution Risk of burns Caution Hot steam Fire hazard Danger High voltage Caution danger of life Inobservance can endanger severe injury or death Do not dispose the combi steamer with domestic waste A Attention Possibly dangerous situation that can endanger minor injury Safety information Instal
23. risdiction Please note For correct sizing of the gas line following points must taken into the consideration 1 total load of the kitchen 2 individual firing rates of each appliance being serviced by the gas line and meter 3 The distance between the last appliance being serviced and the gas meter 4 Last the number of fittings in the gas line for that distance e The installation must be carried out in accordance with the manufacturer s assembly instructions and in accordance with recognised technical rules e The installation of different makes and different types of individual burner parts and of so called gas saver units is not permitted e Before the combi steamer a gas shut off valve must be provided for on site e Before connecting ensure that the set gas type of the appliance is the same as the gas type available at the site of installation e f operating with liquid gas the installation of the combi steamer below ground level is prohibited e Ensure that mains connection is protected from mechanical damages and heat e Units with a fixed rigid connection must be secured to prevent being moved around e Check the gas line pressure e After setting up converting and repairing gas consuming appliances check all parts carrying gas for leaks e Do not spray foaming spray on the flame monitoring control s wires e When setting up the combi steamer for the first time refer to the information plate Important To ens
24. talled underneath the oven There must not be any sources of heat or moisture underneath or in the immediate vicinity of the appliance such as deep fat fryers or portable stoves In case of installation close to materials that risk burning observe the instructions of fire prevention Minimum distance from sources of heat and moisture 500 mm When using deep fat fryers or portable stoves next to the appliance make sure that they are kept at a suitably safe distance from it based on the radius of action of the shower head There is a serious risk of the operator sustaining burns if water is sprayed into hot fat The equipment must be secured against tilting and falling down The machine may only be set up in a location with adequate lighting for users We recommend to install the ovens on top of original Eloma lower racks supports or else Eloma warming cabinets WU 14 In case of installations on top of worktables ensure sufficient stability and load capacity Table top models It is mandatory to set up the appliance in horizontal position True up minor unevenness with the vertically adjustable feet Distance to right and left sides at least 50 mm We recommend to leave a distance of 50 mm to the rear of the oven however it is possible to set it up right against the wall Weight of the Table models 6x 1 1 40x 1 1 150 kg 175 kg Floor models Floor models must invariably be operated with the trolley also when preheating
25. ure that the burner settings made at the factory conform with the actual installation conditions the waste gas CO CO2 from the gas combisteamer must be analysed during commissioning The burner settings must be checked and if necessary adjusted by an authorized service in accordance with the commissioning report for gas combi steamer The verified parameters and the new values must be documented in the commissioning protocol See also checklist service manual 15 Initial start up The initial start up procedure must also be carried out when setting up unit after longer operational interruptions or after maintenance work filling of gas inlet Insert fat filter and drain sieve into the cooking chamber Insert left and right hand in racks into the cooking chamber Follow the instructions for using the water softener Turn the airventilation on gt Open the gas shut off valve at the installation site gt Switch on the combi steamer set temperature 300 C 100 humidity and time 1 00 houers and start e f there is not sufficient gas available in the gas supply line the combi steamer blocks the gas supply a buzzer sounds and the Info line displays the symbol no flame e Allow the buzzer to sound for approx 5 7 seconds gt On combisteamer Genius T gas press sensor key restart gas gt On combisteamer Multimax B gas Use key tj to acknowledge gas fault messages gas combisteamer starts automatical
Download Pdf Manuals
Related Search
Related Contents
CenturyTel of Evangeline, Inc Supermicro X10DRW-i Bedienungsanleitung 6769 HERMA Address labels Premium A4 63.5x38.1 mm white paper matt 525 pcs. Magellan MG32LRF : Manuel d`installation SkyLink LS-318 User's Manual pdf Adobe Acrobat - Rolf C. Hagen Inc. QUICK START PROGRAMMING - Intercom Repairs London, All Coach/Power - Sport Tiedje Copyright © All rights reserved.