1. fig 3 in position MIN or MAX TECHNICAL CHARACTERISTICS Power supply with 9 alkaline battery type 6LF22 6LR61 Protection against polarity inversion COSMO clicca 26 uA Consumption UE RESI IA 35 mA SII FE IE AA SENS Operating frequency laying in the 1st sector of VHF spectrum quartz controlled Radiated peak DORE nantes de ae a se tee teen Re 0 a EEEE 1mW Lasting of the transmitted signal PRE EE 1 7 sec Led for visual check that the transmission has occured The signalling of discharged battery is indicated with the lighting up of the red led Automatic activation of the battery down 6V channel Automatic activation of the antisabotage channel against opening and tear off Transmission code generated by a microprocessor through an algorithm Access to a part of the transmission code by means of a trinary dip switch 6561 combinations Usable range of transmitted signal 100 m in free air Battery duration for more than 30 000 transmission before the battery down signal is sent RECIPES EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEERE EREEREER REEERE EEE 10 45 C Double element pyroelectric sensor with automatic compensation of the temperature Protected against radiofrequencies up to 1 GHz electrostatic discharges up to 8 000 V white light alogen lamps Stabilization time of the sensor after supply of power 80s Protection mechanical Pil aaa IP30 LI 150 x 72 x 57
2. di 5 6 con unica zona protetta su piano orizzontale Spessore di circa 3mt a 30mt Installare il rilevatore come in figura 4 e AE IR OTR copertura a tenda orizzontale per protezioni perimetrali indicato per la rilevazione di intrusioni da soffitto Portata 15 mt apertura sul piano orizzontale a 62 con unica zona protetta Spessore della tenda di circa 1 5mt a 15 mt angolo di copertura 5 6 Installare il rilevatore come in figura 5 rilevatori sono stati realizzati per poter essere collegati con una centrale di allarme senza fili Il sistema di codificazione del segnale e la trasmissione della frequenza controllata al quarzo rendono questi apparecchi i pi tecnologicamente avanzati nel loro genere Il codice di trasmissione viene generato da un microprocessore in modo automatico per mezzo di un algoritmo che elabora il codice impostato dall utilizzatore per mezzo di un dip trinario rendendo l informazione trasmessa immune da qualsiasi tipo di interferenza Il rilevatore in grado di trasmettere quattro canali d informazione ben distinti ALLARME ALLARME DI SABOTAGGIO SEGNALAZIONE PILA SCARICA RESET CAMBIO PILA Il canale di ALLARME viene inviato quando viene attraversata una zona protetta successivamente il rilevatore si interdice per 90 secondi ed eventuali successive rilevazione entro questo tempo azzerano il tempo prolungando l effetto d interdizione Il canale di ALLARME DI SABOTAGGIO viene inviato se viene aperto il
3. fori aperti non utilizzati per evitare falsi allarmi Fissato il rilevatore verificare che la protezione anti strappo sia chiusa EVITARE IN MODO ASSOLUTO l installazione nelle vicinanze di una fonte di calore o alla luce diretta del sole vedi Fig 2 la presenza di animali nell area protetta che esistano a causa di oggetti mobili scaffalature ecc presenti nell area protetta zone di ombra non rilevabili dal sensore toccare con le dita della mano o con qualsiasi altro oggetto la sonda rilevatrice posizionare il rilevatore su di una superficie metallica MESSA IN FUNZIONE E TARATURA DEL RILEVATORE Prima di alimentare il rilevatore impostare un codice di identificazione agendo sul dip switch CODE Fig 3 e ricopiarlo sul dip switch presente sulla centrale ricevente Si consiglia di evitare di codificare il rilevatore tenendo tutti e otto i dip allineati in quanto sono impostazioni non affidabili Quando il rilevatore viene alimentato per la prima volta bisogna attendere circa 80 secondi prima che entri in funzione al termine di questa fase il rilevatore invia automaticamente un segnale di allarme accendendo tutti e due i led Per poter procedere alle verifiche di copertura del rilevatore senza attendere i 90 secondi di interdizione inserire il cavallotto JP2 Fig 3 nella posizione TEST in questo modo il tempo d interdizione si riduce a 10 secondi E INDISPENSABILE che al termine delle operazioni di messa a punto del
4. plane with 19 protected zones Thickness of the curtain of about 1 5m at 15m 5 6 protection angle Install the detector as fig 4 e AE IR VTR for long range perimeter protection suitable for the ceiling protection of lateral glass doors in industrial buildings Range 30m 5 6 opening with one protected zone on horizontal plane Thickness of about 3m at 30m Install the detector as fig 4 AE IR OTR for horizontal curtain perimeter protection suitable for the detection of intrusions from the ceiling Range 15m 62 opening on horizontal plane with one protected zone Thickness of the curtain of about 1 5m at 15m 5 6 protection angle Install the detector as fig 5 These detectors are designed for wireless connection to an alarm station The signal coding system and the quartz controlled frequency transmission make these detectors the most technologically advanced equipment of this kind The transmission code is generated automatically by a microprocessor through an algorithm that processes the code set by the user by means of a trinary dip switch the information transmitted is free of any kind of interference The detectors can transmit 4 well distinct information channels ALARM SABOTAGE ALARM BATTERY DOWN SIGNAL RESET CHANGE BATTERY The ALARM channel is transmitted when a protected zone is crossed the detector is then disabled for 90 seconds and possible further detections during this lapse of time will reset the t
5. rer le jumper JP2 dans la position TEMP Deux niveaux de sensibilit permettent d int grer le d tecteur dans toute condition de travail ins rez le jumper UPI fig 3 dans la position MIN ou MAX CARACTERISTIQUES TECHNIQUES Alimentation avec pile alcaline 9 V type 6LF22 6LR61 Protection contre l inversion de polarit C ns mmation PEDO EEE 26 uA BOI 0 ORGA AE IE OT 35 mA R glage de la sensibilit nai SENS Fr quence de travail situ e dans le ler secteur du spectre VHF contr l e quartz PUS An SC Vee cee ea da en a ad nn nn ee lee Re et a a 1 mW Dur e du Signal transmis ZII 1 7 sec Led verte pour le contr le visuel de transmission effectu e Led rouge pour le contr le visuel de pile d charg e Activation automatique du canal pile d charg e 6V Activation automatique du canal antisabotage contre l ouverture et contre l arrachement Code de transmission g n r par microprocesseur au moyen d un algorithme Acc s une partie du code transmission au moyen d un dip switch ternaire 6561 combinaisons Port e utile du signal transmis 100 m en air libre Autonomie de la pile plus de 30 000 transmissions avant l envoi du signal pile d charg e Temp rature E RA 10 45 C Capteur pyro lectrique a double lement avec compensation automatique de la temp rature Prot g contre radiofr quences jusqu 1 GHz d charges lectrostatiques jusqu 8 000 V lumi re blanche lampes h
6. rilevatore il cavallotto JP2 venga inserito nella posizione TEMP Esistono due livelli di sensibilit per poter integrare il rilevatore a qualsiasi condizione di lavoro ambientale inserire il cavallotto JP1 Fig 3 nella posizione MIN o MAX CARATTERISTICHE TECNICHE Alimentazione con pila alcalina 9 Volt tipo 6LF22 6LR61 Protezione contro inversione di polarit Assorbimento a tripos Ossie ae ee RR a aa aaa 26 uA Assorbimento In allar Merasa ae ere ne AE E ee ethene Ea Ue EAEE T EE ee Oe Seem tire E EE E rer REEE aE rr 35 mA Reuolazione Sensibile rn i ui SENS Frequenza operativa inserita nel 1 settore dello spettro VHF controllata a quarzo Polenza di piccola ona 1mW D rata d l segnale a SINS SO atelier ei 1 7 sec Diodo led verde per controllo visivo di avvenuta trasmissione Diodo led rosso per controllo visivo segnalazione pila scarica Attivazione automatica del canale di pila scarica a 6 Volt Attivazione automatica del canale di antisabotaggio anti apertura e anti strappo Codice di trasmissione generato da microprocessore per mezzo di un algoritmo Accesso ad una parte del codice di trasmissione per mezzo di un dip switch ternario 6561 combinazioni Portata utile del segnale trasmesso circa 100 mt in aria libera Autonomia della pila per oltre 30 000 trasmissioni prima che venga inviato il segnale di pila scarica lemperat ra di es rcizi arri ni da 10 a 45 C Sensore piroelettrico doppio elemento compensat
7. EDINTEC S R L VEEXALBANO ELETTRONICA spa 20090 Pieve Emanuele MI PRODUZIONE APPARECCHIATURE ELETTRONICHE PER LA SICUREZZA C F e P IVA 03423950967 Tel 02 91988336 CI RIVELATORI VOLUMETRICI ALL INFRAROSSO SENZA FILI AE IR AR AE IR OTR AE IR VTR Questi rilevatori volumetrici all infrarosso passivo si contraddistinguono per la cura riservata nella definizione dell aspetto estetico e per la particolare attenzione nella scelta tecnologica dei componenti che li compongono che rendono elevata l affidabilit del prodotto Tutti i rilevatori sono prodotti in tecnologia SDM INTEGRATA per garantire una immunit totale a qualsiasi tipo di disturbo diretto e indotto tutti gli elementi critici sono stati appositamente schermati rilevatori utilizzano un sensore piroelettrico a doppio elemento e a basso rumore compensato in temperatura e protetto dai disturbi in radio frequenza e dai disturbi generati dalla luce bianca rilevatori si differiscono per tipo di lente applicata e sono AE IR AR copertura a tenda orizzontale per protezione di ambienti con presenza di animali Portata 15mt apertura sul piano orizzontale a 156 con 19 zone protette Spessore della tenda di circa 1 5mt a 15 mt angolo di copertura 5 6 Installare il rilevatore come in figura 4 AE IR VTR copertura a lungo raggio per protezioni perimetrali indicato per la protezione a soffitto delle vetrate laterali presenti nei capannoni industriali Portata 30 mt apertura
8. ON Ne percez que les trous n cessaires pour le montage dans la position choisie D autres trous inutilis s peuvent causer des fausses alertes Apr s l installation assurez vous que la protection contre l arrachement est ferm e IL FAUT ABSOLUMENT EVITER l installation pr s d une source de chaleur l exposition directe la lumi re solaire fig 2 la pr sence d animaux dans la zone prot g e zones d ombre caus es par des meubles tag res etc qui ne peuvent pas tre d tect es par le capteur de toucher le d tecteur avec les doits ou d autres objects positionnez le d tecteur sur une surface m tallique MISE EN SERVICE ET MISE AU POINT DU DETECTEUR Avant d alimenter le d tecteur choissez l aide du dip switch CODE fig 3 un code d identification et copiez ce code dans le dip switch de la centrale d alarme Il est conseill d viter de codifier le d tecteur en gardant tous les huit dips align s car ce sont des programmations non fiables La premi re fois qu on alimente le d tecteur il faut attendre 80 s environ avant que le d tecteur se met en marche A la fin de cette phase le d tecteur envoie automatiquement un signal d alarme en allumant les deux leds Pour contr ler le champ de d tection sans attendre les 90 s d inhibition ins rez le jumper JP2 fig 3 dans la position TEST le temps d inhibition sera r duit 10 s A la fin des op rations de mise au pont il est INDISPENSABLE d ins
9. alog nes Temps de stabilisation du capteur apr s l alimentation en courant serrer 80 s Prot ction partie MEIN I date IP30 LC 150 x 72 x 57 mm 0 EI IZ E ERA 130 g Compatibilit de fonctionnement avec tout le centrales del la serie SIRIO le radio r peteur AE RPT1 les circuits interface AE RX MC2 AE RX MC6 AE DCD MC8 pour connecter ces d tecteurs avec des centrales cabl es DIAGRAMMI DIAGRAMMES DIAGRAM AE IR OTR AE IR VTR A N ALBANO ELETTRONICA SpA RE IR TF ALBANO ELETTRONICA S p A Via Porpora 93 20131 Milano Italy Tel 02 2841431 02 26149567 Fax 02 2846868
10. coperchio del rilevatore o se viene distaccato dalla parete ed ha una durata di soli 1 7 secondi anche se l apertura perdurasse Se la manomissione non viene ripristinata ogni volta che il rilevatore invia un segnale di allarme abbina una segnalazione di sabotaggio Il canale di SEGNALAZIONE PILA SCARICA viene inviato quando la pila raggiunge il valore di 6 Volt avvertendo l utilizzatore di provvedere alla sua sostituzione La segnalazione di pila scarica viene visualizzata con l accensione del diodo led rosso Qualora non venisse sostituita ogni qualvolta interviene il rilevatore viene inviato oltre al segnale di allarme anche quello di pila scarica Una volta effettuato il cambio della pila se il rilevatore collegato con una centrale della serie SIRIO tramite il pulsante RESET CHANGE BATT Fig 3 si deve attivare il quarto canale di trasmissione per resettare la centrale vedi manuale di istruzioni della centrale SIRIO AVVERTENZE PER UNA CORRETTA INSTALLAZIONE Installare il rilevatore su pareti rigide prive di vibrazioni posizionando il sensore in modo che l intruso incroci l area protetta vedi Fig 1 Sono previste 2 posizioni diverse di fissaggio piatto a parete e ad angolo per rispondere alle pi svariate esigenze di copertura mantenendo solido il corpo ed evitando il rischio di manomissioni dovute alla presenza di una staffa di sostegno ATTENZIONE Sfondare esclusivamente le predisposizioni scelte e non lasciare
11. e le couvercle du d tecteur ou si on arrache le d tecteur de la paroi Il ne dure que 1 7 s peu importe si la condition d ouverture persiste Si le sabotage n est pas r sett toutes les fois que le d tecteur envoie un signal d alarme il transmettra aussi une signalisation de sabotage Le canal SIGNALISATION PILE DECHARGEE est trasmis quand la pile baisse la valeur de 6V pour informer qu il faut remplacer la pile La signalisation de pile d charg e est visualis e avec l allumage de la led rouge Si l usager ne remplace pas la pile toutes les fols que le d tecteur intervient en plus du signal d alarme il transmettra aussi le signal pile d charg e Apr s le remplacement de la pile si le d tecteur est connect avec une de nos centrales d alarme SIRIO il faut activer au moyen du poussoir RESET CHANGE BATT fig 3 le quatri me canal de transmission de fa on r setter la centrale d alarme voir le Manuel d instructions de la centrale SIRIO INSTRUCTIONS D INSTALLATION e Le d tecteur doit etre install sur une paroi rigide sans vibrations dans une position qui oblige l intrus croiser la zone prot g e fig 1 e On a pr vu 2 positions de fixation diff rentes verticale sur la face de la paroi ou sur coin de paroi afin de satisfaire toute exigence de protection Le corps du d tecteur est fix directement la paroi on vite ainsi le risque d effraction du l utilisation d un trier ATTENTI
12. ime and so protract the inhibition effect The SABOTAGE ALARM channel is transmitted if the detector s cover is opened or if the detector is detached from the wall It lasts 1 7 s only no matter if the opening condition persists If the tampering is not reset every time the detector sends an alarm signal it will also send a sabotage signal The BATTERY DOWN channel is transmitted when the battery voltage drops to 6V to inform the user that the battery has to be replaced Red led for visual signalling of discharged battery If the battery is not replaced every time the detector comes into action in addition to the alarm signal also the battery down signal will be sent After replacing the battery if the detector is connected to a with one of our SIRIO alarm stations you have to activate by means of the RESET CHANGE BATT button fig 3 the 4th transmission channel in order to reset the alarm station see Instructions Manual for SIRIO INSTRUCTIONS FOR A CORRECT INSTALLATION e The detector has to be installed on a vibration free stiff wall in a positions that compels the intruder to cross the protected area see fig 1 e Two different fixation positions are possible upright on wall surface or angular in order to meet the most varied protection requirements The detector s body is fixed directly to the wall This prevents the risk of tampering due to the use of a support bracket ATTENTION Pierce only the holes that are nece
13. mm WEN FS EIA A I 130 g Suitable for use with all SIRIO alarm stations AE RPT1 radio link repeater AE RX MC2 AE RX MC6 and AE DCD MC8 interface circuits for connecting these detectors to cabled alarm stations DETECTEURS VOLUMETRIQUES A RAYONS INFRAROUGES POUR SYSTEMES D ALARME SANS FIL AE IR AR AE IR OTR AE IR VTR Ces detecteurs volum triques a rayons infrarouges passifs se distinguent par leur aspect ext rieur tres agr able et soign et par la haute technologie des composants qui assure un produit de haute fiabilit En effet la technologie de construction SMD INTEGREE garantit une immunit totale contre toute perturbation directe ou induite tous les composants critiques sont convenablement blind s Les d tecteurs sont quip s d un capteur pyro lectrique double l ment et faible bruit avec compensation automatique de la temp rature prot g des perturbations de radiofr quence et de la lumi re blanche Les d tecteurs diff rent entre eux par le type de lentille Mod les disponibles e AE IR AR pour protection rideau horizontal de pi ces en pr sence de animaux Port e 15mt ouverture sur plan horizontal de 156 avec 19 zones prot g es Epaisseur du rideau 1 5mt environ 15mt angle de couverture 5 6 Installer le d tecteur comme fig 4 e AE IR VTR pour protection p rim trale long rayon apte pour la protection au plafond des vitrages lat raux des structures industrielles Port e 30
14. mt ouverture de 5 6 avec une seule zone prot g e sur plan horizontal Epaisseur de 3mt environ a 30mt Installer le d tecteur comme fig 4 e AE IR OTR pour protection p rim trale rideau horizontal apte pour d tecter les intrusions provenant du plafond Port e 15mt ouverture sur plan horizontal de 62 avec une seule zone prot g e Epaisseur du rideau de 1 5mt environ 15mt angle de couverture 5 6 Installer le d tecteur comme fig 5 Ces d tecteurs ont t r alis s pour la connexion sans fil une centrale d alarme Gr ce au syst me de codage et la transmission de la fr quence control e au quartz ces d tecteurs sont du point de vue technologique les plus avanc s dans ce domaine Le code de transmission est g n r automatiquement par un microprocesseur au moyen d un algorithme qui traite le code s lectionn par l usager l aide d un dip switch ternaire l information transmise est exemple de tout type d interf rence Le d tecteur peut transmettre 4 canaux d information bien distincts ALARME ALARME SABOTAGE SIGNALISATION PILE DECHARGEE RESET APRES REMPLACEMENT DE LA PILE Le canal ALARME est transmis si l on traverse une zone prot g e ensuite il se produit une inhibition du d tecteur de la dur e de 90 s Des d tections ventuelles pendant ce laps de temps r settent le temporisateur et par cons quent prolongent l effet d inhibition Le canal ALARME SABOTAGE est transmis si l on ouvr
15. o in temperatura Immunit contro radiofrequenze sino a 1 GHz scariche elettrostatiche sino a 8 000 Volt luci bianche lampade alogene Tempo di assestamento del sensore da quando viene alimentato EEEE EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEREREREEEREEEEEEEEEEEEEEEEEEE EEEE EEEE 80 sec Grado di protezione della Meccanica carica IP30 DICE aa en 150 x 72 x 57 mm Pelo 130 gr Compatibilit di funzionamento con tutte le centrali della serie SIRIO il ponte ripetitore AE RPT1 e le schede di interfaccia AE RX MC2 AE RX MC6 AE DCD MC8 per collegare questi sensori con centrali di tipo cablato INFRARED VOLUMETRIC DETECTORS FOR WIRELESS ALARM SYSTEMS AE IR AR AE IR OTR AE IR VTR These passive infrared volumetric detectors distinguish themselves by their careful finish and by the high technology of their components that ensures a high reliability of the product In fact the SMD INTEGRATED construction technology guarantees full immunity from any direct or induced disturbance all critical components are properly shielded All detectors are equipped with a double element low noise pyroelectric sensor with automatic compensation of the temperature protected from radiofrequency and white light disturbances The detectors differ by the type of lens Following models are available AE IR AR for horizontal curtain protection of rooms in case of presence of animals Range 15m 156 opening on horizontal
16. ssary for the selected installation position Other unnecessary perforations may cause false alarms After installation make sure that the anti tearing protection is closed IT IS ABSOLUTELY NECESSARY TO AVOID installation close to a heat source direct exposition to sun light fig 2 presence of animals in the protected area shadow zones caused by furniture shelves etc that cannot be detected by the sensor to touch the detector with fingers or other objects position the detector on a metallic surface PUTTING INTO OPERATION AND SETTING OF THE DETECTOR Before suppling power to the detector set an identification code by means of the CODE dip switch fig 3 and copy the code in the dip switch of the alarm station We advise to avoid the detector s coding with all the eight dips in aligned positions since this is not reliable When the detector is powered for the first time you have to wait about 80 s before it starts operating On completion of this stage the detector sends automatically an alarm signal displayed by lighting up both leds In order to check the detection field without waiting 90 s inhibition time insert jumper JP2 fig 3 in position TEST the inhibition time will be reduced to 10 s After the setting of the detector IT S NECESSARY to connect the jumper JP2 to TEMP position There are two sensitivity levels for integrating the detector in any environmental working condition insert jumper JP1

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual - PI Manufacturing Corp  Mode d`emploi - Roland Central Europe  Manual de instrucciones  ST8100 Display System Bedienungsanleitung  Contrat de Professionnalisation des intérimaires mode d`emploi  - Shindaiwa  Manual de Usario    POLE STAR CR/CM Installations  Kenmore Elite 5.2 cu. ft. Front-Load Washer - Metallic Silver ENERGY STAR Owner's Manual  