Home

40" electric range installation instructions

image

Contents

1. To gain access to lower terminal block bend lower back cover plate along row of holes shown here Figure 2 e This appliance is manufactured with the frame grounded by connection of a grounding strap between the neutral power supply terminal and the frame If used in USA in a new branch circuit installation 1996 NEC mobile home or Figure 1 recreational vehicle where local code do not 1 Power Supply Cord Kit permit grounding through neutral white wire The user is responsible for connecting the power supply or in Canada remove the grounding strap from cord to the connection block located behind the back the frame and cut the other end near the neutral panel access cover terminal Connect the appliance in usual manner This appliance may be connected by means of permanent hard wiring flexible armored or nonmetallic shielded copper cable when local code 44 WARN ING allow it or by means of a power supply cord kit Risk of fire or electrical shock exists Electrical Shock Hazard if an incorrect size range cord kit is used the e Electrical ground is required on this appliance Installation Instructions are not followed or the e Do not connect to the electrical supply until strain relief bracket is discarded appliance is permanently grounded e Disconnect power to the circuit breaker or fuse box before making the electrical connection e This appliance must be connected to a grounded metallic
2. Si la estufa es movida a otro lugar los soportes antivuelco deben tambi n ser movidos e instalados en la estufa Para controlar la instalaci n apropiada vea el paso n mero 5 Herramientas Necesarias Llave de tuerca de 5 16 8 mm Llave inglesa Taladro el ctrico Broca de 3 16 4 8 mm de di metro Broca para taladro de mamposter a de 3 16 4 8 mm de di si se est instalando en concreto Instrucciones de Instalaci n del Soporte Antivuelco Los soportes se fijan al suelo en la parte trasera de la estufa para sujetar ambos niveladores de las patas traseras Cuando los est instalando al piso aseg rese de que los tornillos no penetren el alambrado el ctrico o plomer a Los tornillos provistos pueden utilizarse en madera o concreto do E Deslice S Hacia atras Soporte Antivuelco A e PS 1 9 cm ore te i Soporte A e TN Antivuelco gps o e Ze 1 9 cm Figura 10 Desdoble la plantilla de papel y col quela plana en el piso con los bordes laterales y el trasero colocados exactamente donde la parte trasera y los lados de la estufa ser n colocados cuando sea instalada Use el diagrama siguiente para ubicar los soportes si no se dispone de la plantilla Marque en el piso la ubicaci n de los 4 agujeros de montaje como se muestra en la plantilla Para facilitar la instalaci n se pueden taladrar agujeros piloto de 3 16 4 8 mm de dia y 1 2 1 3 cm de profundidad en el piso
3. Una arazadera de releva provista debe de estar instalada a est ubicaci n Hacia el 240 V recept culo NOTA Asegurese de quitar la banda de puesta a tierra provista Figura 4 INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Conexi n el ctrica directa al cortacircuito a la caja de fusibles o la caja de empalmes Si el aparato est conectado directamente al cortacircuito a la caja de fusibles o a la caja de empalmes use un cable blindado flexible o no met lico recubierto de cobre con alambre a tierra Provee una abrazadera releva de anclaje hom logo UL a cada extremidad del cable A la extremidad del electrodom stico el cable pase a trav s del agujero de la conexi n directa ver figura 5 en el cord n de la placa de montaje El tama o de los alambres alambre de cobre solamente y las conexiones deben estar conforme al r gimen del electrodom stico Donde los c digos locales permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco vea figura 5 1 Desconecte el suministro el ctrico 2 Quite la banda de puesta a tierra de la caja de empalmes y del marco de la estufa 3 En el cortacircuito la caja de fusibles o la caja de empalmes a Conecte el alambre verde o cobre desnudo el alambre blanco del cable del electrodom stico y el alambre neutral blanco juntos b Conecte los dos alambres negros juntos c Co
4. Welle No toque los elemento Pueden estar bastante calientes para causar quemaduras Quite todo el embalaje de la unidad antes de comprobarla 1 Operaci n de los elementos de superficie Encienda cada uno de los cuatro elementos de superficie y controle que se calienten Verifique el funcionamiento de las luces indicadoras de los elementos de superficie si equipadas Figura 9 2 Funcionamiento de los Elementos del Horno El horno est equipado con un control electr nico Cada funci n ha sido probada en la f brica antes del transporte Sin embargo sugerimos que Ud verifique el funcionamiento de los controles del horno una vez m s V ase el Manual del Usuario para la operaci n Siga las instrucciones par el Reloj Minutero Cocer Asar Convecci n algunos modelos y las funciones de limpieza algunos modelos Cocer Bake Despu s de poner el horno a 350 F 177 C para cocer el elemento inferior debe ponerse rojo Asar Broil Cuando est puesto para BROIL el elemento superior se debe poner rojo Limpieza Clean Cuando el horno est puesto para un ciclo de auto limpieza el elemento superior se pondr rojo durante el per odo de precalentamiento del ciclo Despu s de alcanzar la temperatura de auto limpieza el elemento inferior se pondr rojo 15 Conveccion Convection Cuando el horno se pone a CONV BAKE ROAST a 350 F 177 C los dos elementos se enciendan y se apagan alternan
5. Saque la plantilla y coloque los soportes en el piso con la brida hacia arriba dirigida hacia el frente Alinee los agujeros en los soportes con las marcas en el piso y sujete con los 4 tornillos provistos Los soportes deben estar asegurados al piso firme Si se va a instalar en piso de concreto primero debe taladrar agujeros gu a de 3 16 4 8 mm de di metro usando una broca para taladro de mamposter a Nivele la estufa si es necesario ajustando las cuatro patas niveladoras con una llave Ver la Figura 11 abajo Se requiere un espacio libre m nimo de 1 8 3 2 mm entre la parte inferior de la estufa y los niveladores de las patas traseras para dejar espacio para los soportes antivuelco Deslice la estufa a su lugar asegur ndose de que las patas traseras est n sujetas por los extremos de los soportes La estufa puede necesitar ser movida ligeramente a un lado cuando est siendo empujada hacia atr s para permitir que las patas se alineen con los soportes Despu s de la instalaci n verifique que el soporte antivuelco est enganchado Abra y quite el caj n y verifique que el soporte antivuelco est enganchado ooo niveladora Figura 11
6. 62 2 cm Max No pellizque el cord n el ctrico entre la estufa y la pared NOTA Un espacio m nimo de 24 61 cm entre la superficie de la estufa y el fondo del armario cuando el fondo No selle la estufa a los armarios de lado del armario de madera o metal est protegido por no menos de 1 4 0 64 cm de madera resistente al fuego cubierta por una l mina met lica de MSG n mero 28 0 015 0 4 mm de acero inoxidable 0 024 0 6 mm de aluminio 6 0 02 0 5 mm de cobre Un espacio m nimo de 30 76 2 cm cuando el armario no est protegido D PROFUNDIDAD E M NIMO DE CON PUERTA ANCHO ESPACIO F ALTURA DE MOSTRADOR ABIERTA RECORTADO C PROFUNDIDAD AL A ALTURA B ANCHURA Epente DE LA ESTUFA 48 1 8 40 1 8 26 1 4 66 cm i 36 91 4cm normal 122 2cm 101 9cm con manija 28 1 2 72 40m 44 Y8 1 1 8em 40 1 4 102 2cm 35 7 8 91 1cm min P N 318201704 0907 Rev B English pages 1 8 Espa ol p ginas 9 16 INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Notas importantes para el Instalador 1 Lea todas las instrucciones contenidas en este manual antes de instalar la estufa 2 Saque todo el material usado en el embalaje del compartimiento del horno antes de conectar el suministro el ctrico a la estufa 3 Dos soportes antivuelco DEBEN ser instalados Para detalles vea instrucciones en la p ginas 16 4 Observe todos los c digos y reglamentos pertinente
7. Caja de o Conductor de empalmes A uni n listado UL Cable de la o listado CSA estufa NOTA Aseg rese de quitar la banda de puesta a tierra provista gt Figura 6 Sistema El ctrico a 4 Alambres Ejemplo Caja de empalmes INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Situaci n de caja de uni n Localice la caja de empalmes como se ve en la Figura 7 Si se usa un cord n de servicio el recept culo de pared debe estar localizado seg n las medidas que se indican abajo Construcci n de los Armarios Center DE LA ESTUFA 10 25 4 cm 20 id PARED 50 8 cm _ Ba ez 25 4 cm __ 7 q E UN T x oe 2 out gt PISO 17 8 cm Max 1 i i a DE es Y Su Center UBIQUE LO EL CTRICO DE LA DENTRO DEL REA ESTUFA SOMBREADA Figura 7 Wi Wee Para eliminar el riesgo de quemaduras e incendios al tocar superficies sobrecalentadas se debe evitar colocar espacio para armarios de almacenamiento sobre las estufas con elementos al descubierto Si se instalan armarios sobre la estufa se pueden reducir tales riesgos instalando una campana purificadora que se proyecta horizontalmente un m nimo de 5 12 7 cm m s afuera de la parte inferior de los armarios Si la estufa se va a instalar con un armario a ambos lados marque el centro de la abertura del armario en el piso Y O O Center Line of Rang
8. aseguran la conexi n de la cocina al bloque terminal cuando est instal ndola El corte o la perdida de corriente el ctrica puede ocurrir 2 Acceso a la terminal del bloque y la correa de tierra Para obtener acceso al tablero inferior de bornes doble hacia atr s la placa de la cubierta trasera por la fila de agujeros que se ven aqu Figura 2 Este electrodom stico fue fabricado con el marco aterrizado a trav s de una correa de conexi n entre el neutral de la fuente de alimentaci n y el marco Si es utilizado en los E E U U con un circuito nuevo de instalaci n 1996 NEC en casa sobre ruedas o veh culo recreativo donde el c digo local no permite el atterizaje a trav s del cable neutro blanco o en Canad remueva la correa de aterrizaje del marco y corte el otro extremo cerca de la terminal de neutral Conecte el electrodom stico de la forma usual A ADVERTENCIA Peligro de choque el ctrico La conexion a tierra es requerida para este electrodomestico No conecte al suministro el ctrico hasta que el electrodom stico este conectado a tierra de manera permanente Desconecte el suministro el ctrico hacia la caja de empalmes antes de hacer la conexi n el ctrica Este electrodom stico debe ser conectado a un sistema de alambres permanentes met licos conectados a tierra o una puesta a tierra debe ser conectada al terminal de tierra o un emplonbado al electrodom stico E
9. become red Convection When the oven is set to CONV BAKE ROAST at 350 F 177 C both elements cycle on and off alternately and the convection fan will turn The convection fan will stop turning when the oven door is opened during convection baking or roasting When All Hookups are Complete Make sure all controls are left in the OFF position Before You Call for Service Read the Avoid Service Checklist and operating instructions in your Owner s Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to the warranty and service information in your Owner s Guide for our phone number and address Please call or write if you have inquiries about your range product and or need to order parts 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by properly installed anti tip brackets and screws packed with the range Those parts are located in a plastic bag in the oven Failure to install the anti tip brackets will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it Serious injury might result from spilled hot liquids or from the range itself Follow the instructions below to install the anti tip brackets If range is ever moved to a different location the anti t
10. local codes e Make sure the wall coverings around the range can withstand the heat generated by the range A WARNING VE WARNING To reduce the risk of tipping of the range the range must be secured by properly installed anti tip bracket s provided with the range To check if the bracket s is installed properly remove the lower panel or storage drawer and verity that the anti tip bracket s Is engaged e All ranges can tip e Injury to persons could result e Install anti tip device packed with range Before installing the range in an area covered with linoleum or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F 32 C above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 4 6 4 mm thick plywood between the range and carpeting e Do not obstruct the flow of air at the oven vent nor around the base or beneath the lower front panel of the range Avoid touching the vent openings or nearby surfaces as they may become hot while the oven is in operation This range requires fresh air for proper operation IIA AN Ne Never leave children alone or unattended in the area where an appliance is in use As children grow teach them the proper safe use of all appliances Never leave the oven door open when the range is unattended WISIN Stepping leaning or sitti
11. o solicite informaci n con respecto a su estufa est siempre seguro de incluir el n mero de modelo y de serie y el n mero o letra del lote de la placa de serie de su estufa figura 1 La placa de serie est ubicada aqu Figura 1 1 Estuche de cable del suministro el ctrico El utilizador es responsable de la conexi n del cable del suministro el ctrico al bloque de conexi n situado detr s del panel de acceso El electrodom stico se puede conectar a trav s de un cableado permanente cableado duro cable de cobre blindado armado o cable no met lico flexible cuando el c digo local lo permite o por medio de un kit de cable de alimentaci n NOTA La cocina corrediza el ctrica viene de fabrica con un agujero de di metro 1 1 8 2 9 cm come se muestra en la figura 4 Si un agujero mas largo est necesario retire la arandela de la pre cortada El riesgo de fuego o de choque el ctrico puede aparecer si usa el tama o de cable incorrecto si las instrucciones de instalaci n no son seguidas o si retira la abrazadera de releva Para casas sobre ruedas nuevas instalaciones en los veh culos de recreativos o en las lugares donde los c digos locales no permiten la conexi n del conductor de tierra al neutro un ensamble de suministro el ctrico de 4 conductores para estufas calificado a 125 250 voltios m nimo 40 Amperes m nimo debe de ser utilizad No desajuste las tuercas que
12. other wires to the outer terminals Match wires and terminals by color red wires connected to the right terminal black wires connected to the left terminal 5 Lower the terminal cover and replace the 3 screws Silver Colored Terminal Terminal Block Black Wire 1 1 8 2 9m Dia Direct Connection Hole Punch Out Knockout for 1 3 8 3 5cm Dia Cord Kit Hole A User Supplied Strain relief Must Be Installed at This Location To 240 V Receptacle NOTE Be sure to remove the supplied grounding strap gt __ _ _ _ _ _ _ gt Figure 4 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Direct Electrical Connection to the Circuit Breaker Fuse Box or Junction Box If the appliance is connected directly to the circuit breaker fuse box or junction box use flexible armored or nonmetallic sheathed copper cable with grounding wire Supply a U L listed strain relief at each end of the cable At the appliance end the cable goes through the Direct Connection Hole see Figure 5 on the Cord Mounting Plate Wire sizes copper wire only and connections must conform to the rating of the appliance Where local codes permit connecting the appliance grounding conductor to the neutral white wire see Figure 5 1 Be sure that no power is supplied on the cable from residence 2 Remove the grounding strap from the terminal block and trom the appliance frame 3 In the circuit breaker f
13. see Figure 11 3 Slide range into cut out opening and double check for levelness If the range is not level pull unit out and readjust leveling legs or make sure floor is level Check Operation Refer to the Owner s Guide packaged with the range for operating instructions and for care and cleaning of your range YA NUN Do not touch the elements They may be hot enough to cause burns Figure 9 Remove all packaging from the oven before testing 1 Operation of Surface Elements Turn on each of the four surface elements and check to see that they heat Check the surface element indicator light s if equipped 2 Operation of Oven Elements The oven is equipped with an electronic oven control Each of the functions has been factory checked before shipping However it is suggested that you verify the operation of the electronic oven controls once more Refer to the Owner s Guide for operation Follow the instructions for the Clock Timer Bake Broil Convection some models and Clean some models functions Bake After setting the oven to 350 F 177 C for baking the lower element in the oven should become red Broil When the oven is set to BROIL the upper element in the oven should become red Clean When the oven is set for a self cleaning cycle the upper element should become red during the preheat portion of the cycle After reaching the self cleaning temperature the lower element will
14. the supplied grounding strap ___ _ __ _ _ _ __ gt Figure 6 4 Wire Electrical System Example Junction Box 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Junction Box Location Locate junction box as shown in Figure 7 If a service cord is used the wall receptacle should be located in accordance with the dimensions below Center Line of Range v 0 25 4 cm 20 ALL 50 8 cm gt 10 a _ ae oe 25 4 cm ai jos o a 0 A te A lee oot 7 Max Sl 17 8 cm Max AA PA _ y RR oe a Center Line of Locate Electrical Hook up Range Inside Shaded Area Figure 7 Range Placement YANO EN To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the range should be avoided If cabinet storage space is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinet Center Line of Range Q O Follow instructions for the type of installation you have Figure 8 If range will be installed with a cabinet on both sides draw a center line on the floor between the cabinets see figure 8 If back of range will not be flush with the wall the location of the outlet may not allow the range to be positioned against the wall draw
15. 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE U READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE L IAN FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 40 1 8 Min 101 9cm Woo 234 Min 7cm Min for E eax open door ie bale On left side e al i 18 Min 13 Max only if T JZ 45 7cm Min 33cm Max wa A Grounded Wall Outlet 61cm Min 242 max 62 2cm Max Do not pinch the power supply cord between the range NOTE 24 61 cm minimum clearance between and the wall the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less Do not seal the range to the side cabinets than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet metal 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance when the cabinet Is unprotected C DEPTHTOFRONTOF D DEPTHWITH E MINIMUM F HEIGHT OF A HEIGHT B WIDTH RANGE DOOR OPEN CUTOUT WIDTH COUNTERTOP 48 1 8 40 1 8 26 1 4 66 cm 36 91 4cm standard 122 2cm 101 9cm with Handle 28 1 2 72 4cm cru A Ge an 39 7 8 91 1cm min P N 318201704 0907 Rev B English pa
16. Para e Instale el comprobar si estos est n dispositivo instalados y apretados en antivuelcos su lugar como se debe ase que se ha el borde trasero superior de empacado la estufa y cuidadosamente inclinela hacia adelante para asegurar que la estufa se ancle junto con esta estufa e Antes de instalar la estufa en un rea cuyo piso este recubierto con lin leo u otro tipo de piso sint tico aseg rese de que stos puedan resistir una temperatura de por lo menos 90 F sobre la temperatura ambiental sin provocar encogimiento deformaci n o decoloraci n No instale la estufa sobre una alfombra al menos que coloque una plancha de material aislante de por lo menos 1 4 pulgada entre la estufa y la alfombra e No obstruya el flujo del aire en la ventilaci n del horno ni tampoco alrededor de la base o debajo del panel inferior delantero de la estufa Evite tocar las aberturas o reas cercanas de la ventilaci n ya que pueden estar muy calientes durante el funcionamiento del horno La estufa requiere aire fresco para la operaci n ADVERTENCIA Nunca deje ni os solos o desatendidos en un rea donde un artefacto est siendo usado A medida que los ni os crecen ens eles el uso apropiado y de seguridad para todos los artefactos Nunca deje la puerta del horno abierta cuando la estufa est desatendida INEA No se pare apoye o siente en las puertas o cajones de esta estufa pues puede resultar en serias lesion
17. a line on the floor where the back edge of the range will be Now install anti tip brackets see Anti Tip Bracket Installation page 8 If range will be installed with a cabinet on one side only move the range into final position Draw a line on the floor along the side of the range that is not against the cabinet If back of range will not be flush with the wall the location of the outlet may not allow the range to be positioned against the wall draw a line on the floor where the back edge of the range will be Now install anti tip brackets see Anti Tip Brackets Installation page 8 If range will not be installed against a cabinet move range into final position Mark on the floor along both sides of the range If back of range will not be flush with the wall the location of the outlet may not allow the range to be positioned against the wall draw a line on the floor where the back edge of the range will be Now install anti tip brackets see Anti Tip Brackets Installation page 8 Range Installation NOTE 1 The back of the range may be installed directly against the rear wall of the structure 2 These ranges conform to U L requirements for 0 Spacing from the range to adjacent vertical walls above the countertop level However to reduce possible scorching of vertical walls and to minimize potential fire hazards under abnormal surface unit use conditions such as high heat or no pans a minimum of 2 5 1 cm sp
18. acing should be provided on both sides of the cooktop 3 Ifa wall is present on the left side of range allow a minimum of 2 3 4 7 cm to open the auxiliary door A WARNING Excessive Weight Hazard e Use 2 or more people to move and install range e Failure to follow this instruction can result in back or other injury Preparation 1 Put on safety glasses and gloves Remove oven racks and parts package from inside the oven Remove shipping materials tape and protective film from the range 2 Take 4 cardboard corners from the carton Stack one on top of another Repeat with other 2 corners Place corners lengthwise on the floor in back of the range to support range 3 Firmly grasp the range and gently lay it on its back on the cardboard corners 4 Remove the 4 shipping bolts trom the skid Discard Skid 5 Lay a large piece of cardboard in front of the range Carefully stand the range upright on cardboard 6 Adjust the leveling legs to a point where the range base does not touch the floor 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Leveling the Range Level the range and set cooktop height before installation in the cut out opening if applicable 1 Install an oven rack in the center of the oven 2 Place a level on the rack see figure 9 Take 2 readings with the level placed diagonally in one direction and then the other Level the range if necessary by adjusting the 4 leg levelers with a wrench
19. con la pared marque en el piso donde el borde trasero de la estufa estar Ponga el patr n en el piso y alinee los lados del patr n con las l neas marcadas en el piso Alinee la parte trasera del patr n con la pared trasera O la l nea marcada para la parte trasera de la estufa vea instalaci n del Soportes Antivuelco p gina 8 Instalaci n de la estufa NOTA 1 La parte trasera de la estufa puede ser directamente instalada a ras con la pared trasera de la estructura Estas estufas se conforman a los requerimientos U L para espaciamiento 0 desde la estufa hasta las paredes ver ticales adyacentes arriba del nivel del tablero No obstan te para reducir la posibilidad de quemar las paredes verti Cales y para disminuir el posible peligro de incendio bajo condiciones anormales de uso de la tapa con hornillas como alto calor o la ausencia de cazuelas se debe dejar un espacio de un m nimo de 2 5 1 cm en ambos lados de la tapa Si Una pared se encuentra en el lado izquierdo de la estu fa dejar 2 3 4 7 cm m n par abrir la puerta auxiliar PRECAUCION Peligro de Peso Excesivo e Use 2 personas o m s para mover e instalar la estufa e Si no cumple con esta instrucci n puede resultar en da o a la espalda u otra lesi n Preparaci n 1 P ngase guantes y anteojos de seguridad Quite las parri Ilas del horno y paquete de piezas de adentro del horno Quite materiales de empaque cinta y pel cula protec
20. do en un ciclo y el ventilador se pone en marcha El ventilador de convecci n se parar cuando se abre la puerta del horno durante el cocido o el asado por convecci n Despu s de Terminar la Instalaci n Aseg rese de que todos los controles est n en la posici n OFF apagada Antes de Llamar al Servicio Lea la secci n Lista de control de aver as en su Manual del Usuario Esto le podr ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricaci n de este artefacto Lea la garant a y la informaci n sobre el servicio en su Manual del Usuario para obtener el n mero de tel fono gratuito y la direcci n del servicio Por favor llame o escriba si tiene preguntas acerca de su estufa o necesita repuestos INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Importante Advertencia de Seguridad Para reducir el riesgo de que la estufa se vuelque es necesario asegurarla al piso instalando los soportes antivuelco y los tornillos suministrados con la estufa Las piezas se encuentran en un saco de pl stico en el horno Si no se instalan los soportes antivuelco la estufa se puede volcar si se coloca exceso de peso en una puerta abierta o si un ni o se sube a ella Se pueden ocasionar lesiones graves causadas por los l quidos calientes derramados o por la estufa misma Siga las instrucciones que m s abajo se indican para instalar los soportes antivuelco
21. e O e A Siga las instrucciones para el tipo de instalaci n que usted tenga Figura 8 Si la parte trasera de la estufa no estar a ras con la pared la ubicaci n del tomacorriente puede que no permita que la estufa se pegue a ras con la pared marque el piso donde estar el border trasero de la estufa Ponga el patr n en el piso alineando la l nea del centro del patr n con la marca en el centro de la abertura del armario Ponga el borde trasero del patr n a ras contra la pared trasera o la l nea mar cada para la parte de atr s de la estufa Si la estufa se va a instalar con un armario a s lo un lado mueva la estufa a su posici n final Marque el piso por el lado de la estufa que no estar contra el armario Si la parte trasera de la estufa no estar a ras con la pared la ubicaci n del tomacorriente puede que no permita que la estufa se pegue a ras con la pared marque el piso donde el borde trasero de la estufa estar Ponga el patr n en el piso y alinee el lado del patr n con la l nea marcada en el piso Ali nee la parte trasera del patr n con la pared trasera o la l nea marcada para la parte de atr s de la estufa Si la estufa no ser instalada junta contra un armario mueva la estufa a su posici n final Marque el piso por los dos lados de la estufa Si la parte trasera de la estufa no estar a ras con la pared la ubicaci n del tomacorriente puede que no permita que la estufa se pegue a ras
22. eptaculo cm Dia agujero Alambre Negro Una arazadera de releva provista debe de estar instalada a est ubicaci n Figura 3 Conexi n del cable de cuatro conductores a la cocina 1 Retire los 3 tornillos de la parte baja de la cubierta del cable trasero luego levante la cubierta hacia arriba para tener acceso cubierta de acceso al bloque de conexi n del borne terminal vea figura 2 Retire la correa de la base del bloque terminal y del armaz n del electrodom stico Retenga el tornillo de la base Utilizar los tuercas suministraron en el paquete de la literatura para conectar el alambre de tierra verde del cable de bronce del suministro el ctrico al armaz n del electrodom stico con el tornillo de la base usando el hoyo del armaz n por donde retir la correa de la base vea figura 4 Conecte el alambre neutral blanco del cable de cobre del suministro el ctrico al terminal plateado del centro del bloque terminal y conecte los otros alambres a los terminales externos Baje la cubierta del terminal y vuelva al colocar los 3 tornillos Terminal plata Bloque terminal Alambre AD A Alambre MH DT AOS Negro Y lt I 4 l Ly A EO a Y 4 A SA AA 1 1 8 2 9 cm Dia Agujero de la conexi n directa Retira la arandela pre cortada para 1 3 8 3 5 cm dia agujero Alambre Blanco Puesta a tierra cable de cobre
23. es y puede tambi n causar da o a la estufa e No almacene art culos que puedan interesar a los ni os en los gabinetes sobre la estufa Los ni os pueden quemarse seriamente tratando de trepar a la estufa para alcanzar estos art culos e Los gabinetes de almacenamiento sobre la estufa deben ser evitados para eliminar la necesidad de tener que pasar sobre los elementos superiores de la estufa para llegar a ellos No use el horno como espacio de almacenaje Esto crear una situaci n potencialmente peligrosa e Nunca use la estufa para calentar el cuarto El uso prolongado de la estufa sin la adecuada ventilaci n puede resultar peligroso e No almacene ni utilice gasolina u otros vapores y l quidos inflamables en la proximidad de ste o de cualquier otro artefacto el ctrico Puede provocar incendio o explosi n Ajuste todos los controles a la posici n OFF apagada despu s de haber hecho una operaci n con tiempo programado PARA AUTO LIMPIEZA e Saque la asadera alimentos o cualquier otro utensilio antes de usar el ciclo de auto limpieza del horno Limpi todo exceso de derrame de alimentos Siga las instrucciones de prelimpiado en el Manual del Usuario INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Ubicaci n del N mero de Modelo y de Serie La placa con el numero de serie esta ubicada en el marco delantero del horno detr s de la puerta del horno grande Cuando haga pedidos de repuestos
24. ges 1 8 Espa ol p ginas 9 16 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing range 2 Remove all packing material from the oven compartments before connecting the electrical supply to the range see Preparation page 6 3 Two anti tip brackets located inside the oven cavity MUST be installed see Anti Tip Bracket Installation page 8 4 Observe all governing codes and ordinances 5 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions with your owner s guide for future reference IMPORTANT SAFETY INSTRUCTIONS e Be sure your range is installed and grounded properly by a qualified installer or service technician e This range must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition e The installation of appliances designed for manufactured mobile home installation must conform with Manufactured Home Construction and Safety Standard title 24CFR part 3280 Formerly the Federal Standard for Mobile Home Construction and Safety title 24 HUD part 280 or when such standard is not applicable the Standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI Z225 1 NFPA 501A latest edition or with
25. ip brackets must also be moved and installed with the range To check for proper installation see step 5 Tools Required 5 16 8 mm Nutdriver Adjustable Wrench Electric Drill 3 16 4 8 mm Diameter Drill Bit 3 16 4 8 mm Diameter Masonry Drill Bit if installing in concrete Anti Tip Brackets Installation Instructions Brackets attach to the floor at the back of the range to hold both rear leg levelers When fastening to the floor be sure that screws do not penetrate electrical wiring or plumbing The screws provided will work in either wood or concrete WS slide a Anti Tip Bracket lt ee 34 ii S gt 1 9 cm Anti Tip Pa SS Bracket o SS 1 3 cm Sides of gt range 5 ZT ety Figure 10 Unfold paper template and place it flat on the floor with the back and side edges positioned exactly where the back and sides of range will be located when installed Use the diagram in figure 10 to locate brackets if template is not available Mark on the floor the location of the 4 mounting holes 2 holes per bracket shown on the template For easier installation 3 16 4 8 mm diameter pilot holes Y 1 3 cm deep can be drilled into the floor Remove template and place brackets on floor with turned up flanges to the outside see figure 10 Line up holes in brackets with marks on floor and attach with 4 screws provided 2 screws per bracket Brackets must be secured to solid floor If attaching to concrete f
26. l no seguir ninguna de estas instrucciones podr a causar fuego heridas personales o choques el ctricos INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 3 Conexion el ctrica a la cocina Conexion del cable a tres alambres la cocina Si los c digos locales permiten la conexi n del conductor a tierra del armaz n al alambre neutral del cable de bronce del suministro el ctrico vea figura 3 1 Retire los 3 tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso luego levante la cubierta hacia arriba para tener acceso al bloque de conexi n del borne terminal vea figura 2 Utilizar los tuercas suministraron en el paquete de la literatura para conectar la parte neutral del cable de bronce de suministro el ctrico al terminal plateado que se encuentra al centro del bloque terminal y conectar los otros alambres a los terminales externos Aparee los alambres y los terminales seg n el color alambres rojos conectados al terminal derecho alambres negros conectados al terminal izquierdo vea figura 3 Baje la cubierta del terminal y vuelva al colocar los 3 tornillos Terminal plata Y ys AZ N Alambre Bloque terminal pe At Cordon de la placa de montaje Neutro Alambre Blanco Banda de puesta a tierra SL 1 1 8 2 9 cm Agujero de la conexi n directa Retira la arandela pre Hacia el 240 V cortada para 1 3 8 3 5 Rec
27. loor first drill 3 16 4 8 mm dia pilot holes using a masonry drill bit Level range if necessary by adjusting 4 leg levelers with wrench See Figure 11 A minimum clearance of 1 8 3 2 mm is required between the bottom of the range and the rear leg levelers to allow room for the anti tip brackets Slide range into place making sure rear legs are trapped by ends of brackets Range may need to be shifted slightly to one side as it is being pushed back to allow rear legs to align with brackets After installation verify that the anti tip bracket Is engaged Open and remove drawer and check to make sure the anti tip bracket is engaged Figure 11 INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR U LOCAL DE ELECTRICIDAD LEA Y GUARDE ESTAS INSTRUCCIONES PARA L REFERENCIA FUTURA PARA SU SEGURIDAD No almacene ni utilice gasolina u otros vapores y liquidos inflamables en la proximidad de este o de cualquier otro artefacto 40 1 8 Min 101 9 cm 2 3 4 Min 7 cm Min para puerta abierta 30 Min Si hay uno pared 76 2 cm Min a el lado izquierdo 13 Min es M x solamente 45 7 cm M n 33 cm Max con las patas extendidas Toma corriente de pared puesto a tierra K 61 cm Min 24 1 2 Max
28. necte los dos alambres rojos juntos Cable de la fuente de alimentaci n Alambre neutro anes Alambres negros Alambres rojos lt Caja de empalmes Alambre blanco AN See a Se Alambre Conductor de desnudos A uni n listado UL o verdes Cable de la listado CSA estufa NOTA Aseg rese de quitar la banda de puesta a tierra gt provista Figura 5 Sistema El ctrico a 3 Alambres Neutral puesta a tierra Ejemplo Caja de empalmes 13 Donde los c digos locales NO permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco o si est conectado con un sistema a 4 alambres vea figura 6 1 Desconecte el suministro el ctrico 2 Separe el alambre verde o cobre desnudo y el alambre blanco del electrodom stico 3 En el cortacircuito la caja de fusibles o la caja de empalmes a Conecte el alambre blanco del cable del electrodom stico al alambre neutral blanco b Conecte los 2 alambres negros juntos c Conecte los 2 alambres rojos juntos d Conecte el alambre verde o de cobre desnudo de la puesta a tierra del alambre al alambre de puesta a tierra del cortacircuito de la caja de fusibles o de la caja de empalmes Cable de la fuente de alimentaci n Alambre desnudo o verde Alambre blanco Alambres rojos Alambres negros Alambre desnudo o verde Alambre blanco lt i e
29. ng on the door s or drawer of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface units cabinet storage space above the units should be avoided Do not use the oven as a storage space This creates a potentially hazardous situation Never use your range for warming or heating the room Prolonged use of the range without adequate ventilation can be dangerous Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance Explosions or fires could result Reset all controls to the off position after using a programmable timing operation DURING SELF CLEAN e Remove broiler pan food and other utensils before self cleaning the oven Wipe up excess spillage Follow the pre cleaning instructions in the Owner s Guide 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Model and Serial Number Location 2 Access to Terminal Block amp The serial plate is located on the oven front frame behind gt the large oven door Grounding strap When ordering parts for or making inquiries about your range always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range Figure 1 Serial Plate Location
30. permanent wiring system ora grounding connector should be connected to the grounding terminal or wire lead on the appliance For mobile homes new installations or recreational vehicles use only a power supply kit designed for a range at 125V 250V 50A recommended minimum 40A Cord must have either 3 when local code permits grounding through neutral or 4 conductors Terminal on end of wires must be either closed loop or open spade lug with upturned ends Cord must have strain relief clamp Do not loosen the nuts which secure the factory installed range wiring to terminal block while connecting range Electrical failure or loss of electrical connection may occur Failure to do any of the above could result in a fire personal injury or electrical shock NOTE Range is shipped from factory with 1 1 8 dia hole as shown in figure 3 If a larger hole is required punch out the knockout 40 ELECTRIC RANGE INSTALLATION INSTRUCTIONS 3 Electrical Connection to the Range Three Conductor Wire Connection to Range If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 3 1 Remove the 3 screws at the lower end of the rear wire cover then bend the lower end of the rear wire cover access cover upward to expose range terminal connection block see Figure 2 2 Using the nuts supplied in the literature package connect the neutral of the copper power s
31. s 5 Deje estas instrucciones con el comprador Nota Importante para el Consumidor Conserve estas instrucciones y el Manual del Usuario para referencia futura IMPORTANTES INSTRUCCIONES DE SEGURIDAD e Aseg rese de que la estufa sea instalada y conectada a tierra en forma apropiada por un instalador calificado o por un t cnico e Esta estufa debe ser el ctricamente puesta a tierra de acuerdo con los c digos locales o en su ausencia con el C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n e La instalaci n de aparatos dise ados para instalaci n en casas prefabricadas m viles debe conformar con el Manufactured Home Construction and Safety Standard t tulo 24CFR parte 3280 Anteriormente el Federal Standard tor Mobil Home Construction and Safety titulo 24 HUD parte 280 o cuando tal estandard no se aplica el Standard for Manufactured Home Installation 1982 Manufactured Home sites Communities and Setups ANSI Z225 1 NFPA 501A edici n m s reciente o con los c digos locales Aseg rese de que el material que recubre las paredes alrededor de la estufa pueda resistir el calor generado por la estufa ADVERTENCIA f ADVERTENCIA e Todas las Para reducir el riesgo de estufas pueden que se vuelque la estufa volcarse hay que asegurarla e Esto podr a adecuadamente resultar en coloc ndole los soportes lesiones antivuelco que se personales proporcionan
32. tiva de la estufa Tome las 4 esquinas de cart n de la caja de empaque Co l quelas una encima de otra Repita esta operaci n con las otras 2 esquinas Coloque las esquinas longitudinalmente en el piso detr s de la estufa para apoyarla Sujete firmemente la estufa y suavemente recu stela en su respaldo en las esquinas de cart n Quite los 4 pernos de empaque de la corredera Descarte la corredera Ponga el cart n delante de la estufa Cuidadosamente pare la estufa en el cart n Ajuste la patas de nivelaci n al punto en que la base de la estufa no toque el piso INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 40 Nivelacion de la estufa Nivele la estufa y ajuste la altura de la estufa antes de instalarla en la abertura 1 Coloque una parrilla del horno en el centro del horno 2 Ponga un nivel sobre la parrilla vea figura 9 Tome dos lecturas con el nivel puesto diagonalmente en una direc ci n y despu s en la otra Nivele la estufa si es necesario ajustando las 4 patas niveladoras con una llave de tuercas Figura 11 Deslice la estufa en la abertura y verifique la nivelaci n otra vez Si la estufa no es nivelada tire la unidad hacia afuera y reajuste las patas niveladoras o verifique que el piso sea nivelado Comprobaci n del Funcionamiento Consulte el Manual del Usuario incluido con la estufa para instrucciones de operaci n y instrucciones para el cuidado y limpieza de su estufa
33. upply cord to the center silver colored terminal of the terminal block and connect the other wires to the outer terminals Match wires and terminals by color red wires connected to the right terminal black wires connected to the left terminal see figure 3 3 Lower the terminal cover and replace the 3 screws Silver Colored Terminal Block Neutral White Wire Ait Grounding J Strap 1 1 8 2 9 cm Dia Direct Connection Hole Punch Out Knockout A User Supplied Strain relief Must Be Installed at This To 240V for 1 3 8 3 5 cm Dia Location Receptacle Cord Kit Hole Figure 3 Four Conductor Wire Connection to Range Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 4 1 Remove the 3 screws at the lower end of the rear wire cover then raise the lower end of the rear wire cover access cover upward to expose range terminal connection block see figure 2 2 Remove the grounding strap from the terminal block and from the appliance frame 3 Using the nuts supplied with the literature package connect the ground wire green of the copper power supply cord to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was removed see Figure 4 4 Connect the neutral of the copper power supply cord to the center silver colored terminal of the terminal block and connect the
34. use box or junction box a Connect the green or bare copper wire the white appliance cable wire and the neutral white wire together b Connect the 2 black wires together c Connect the 2 red wires together Cable from Residence Neutral white Wire Red Junction Box White Wire Green A U L listed Conduit or Bare Copper Connector or CSA Wire Cable from listed Appliance NOTE Be sure to remove the supplied grounding strap __ _ __ _ _ _ __ gt Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral white wire or if connecting to 4 wire electrical system see Figure 6 Be sure that no power is supplied on the cable trom residence 2 Remove the grounding strap from the terminal block and from the appliance frame 3 In the circuit breaker fuse box or junction box a Connect the white appliance cable wire to the neutral white wire b Connect the 2 black wires together c Connect the 2 red wires together d Connect the green or bare copper grounding wire to the grounding wire of the circuit breaker fuse box or junction box Cable from Residence Green or Bare Copper Wire Green or Bare Copper Wire SS T ee White Wire non A Box AA Connector or CSA Cable from listed Appliance NOTE Be sure to remove