1. Purgeur d air Figure 2 Eau sans fer TT So Entr e Eau adoucie sand fer Vers le cont lleur de la pompe l Vers le cont lleur R servoir l de la pompe Sous pression f Primaire R servoir Sous pression Secondaire Vidange Vidange Eau brute du puits Adouci Filtre de fe R g een Ree a Interrupteur de Hydro lectrovalve Interrupteur de pression chargeur pression Figure 3 Eau sans fer ties Purgeur d air g Eau adoucie Eau adoucie sand fer s pour Entr e l etxt rieur Vers le cont lleur de la pompe J Vidange Vidange R servoir Sous pression rat Eau brute du puits f Eau brute ES RE Eu Adoucisseur Filtre de fer Interrupteur de Hydro lectrovalve pression chargeur N B Avant de commencer l installation lisez les directives de la page 6 Nettoyage du system de tuyauterie pour savoir quelles proc dures doivent tre suivies par avant Installation de la pompe air avec contr leur d bitm trique Mascontrol comme source d alimentation 1 suivre lorsque le pressostat et la pompe air sont situ s des endroits diff rents lorsque la pompe est de type pression constante ou vitesse variable 2 Le Mascontrol agit comme contr leur et d tecteur de d bit 3 Branchez la pompe air la prise du Mascontrol Voir le manuel du Mascontrol pour le
2. 2 Le chiffre dans cette case indique le nombre de fois que votre filtre doit initier le remous par p riode de douze jours Exemple Vous tes 4 dans votre famille et il y a 8 ppm dans votre eau V rifiez le guide pour trouver la case l intersection du 4 pour les membres de la famille et 8 pour la concentration de fer La valeur donn e est 2 Celle ci indique que la minuterie du contr leur devrait tre programm e pour initier le remous deux fois par douze jours c est dire chaque six jours Si la valeur de la case avait t de 3 il faudrait alors initier le remous 3 fois par douze jours ou chaque quatre jours Pour calculer la frequence du remous applications sp ciales Pour assurer une capacit de r serve ad quate et pr venir contre une perte de pression d eau entre chaque remous une valeur de 15 000 et non pas la capacit totale de 30 000 ppm est prise pour calculer la fr quence du remous D terminez votre fr quence de remous de cette fa on 1 Faites une estimation du montant de fer qui doit tre filtr par jour l aide de l quation suivante Nombre de membres dans la famille x 75 gallons d eau par personne nombre de gallons d eau pour usage sp cial nombre de gallons d eau requis par jours x concentration de fer en ppm montant de fer filtrer par jour en ppm 2 Trouvez la fr quence du remous requise en utilisant le montant de fer filtrer par jour avec l quation suivante 15
3. air Purgeur d air z Braukman Braukman FERME Voir Figure 7 R servoir R servoir sous pression sous pression Diaphragme l air pour arroser Figure 8 le couvercle d chappement d air doit tre desserr ou enlev pour que l aire puisse s chapper du purgeur Indicateur de position Bague du purgeur po x 1 8 po t en cuivre de po X po X po PO NES Directives sp ciales pour installations en fourche et avec alimentation publique Si l installation comprend une fourche des conduites il doit y avoir un r servoir sous pression secondaire d install comme indiqu la figure 2 page 4 Si l installation est faite partir d une alimentation d eau publique un r servoir sous pression doit tre install comme indiqu la figure 3 page 4 Il est recommand d utiliser un r servoir sous pression air eau standard avec purgeur d air pour les deux types d installation un r servoir ayant la m me capacit que si l installation tait faite sur un syst me puits priv e Notez aussi qu une lectrovalve fermeture normale est requise pour chacune des deux types d installation Suivez les directives d installation standards ci haut tout en appliquant les additions et modification suivantes 1 Installez le r servoir sous pression le r servoir secondaire de la figure 2 page 4 de la fa on indiqu e sur le diagramme appropri 2 Installez l lectrovalve fermeture normale la suite du compteu
4. est sous 6 0 consultez votre revendeur Le pH Le pH de l eau est une mesure d acidit ou d alcalinit L eau est acide si son pH est au dessous de 7 0 est alcaline si son pH est au dessus de 7 0 ou est neutre si son pH est 7 0 Plus un pH est au dessous de 7 0 plus le niveau d acidit sera grand et plus un pH est au dessus de 7 0 plus le niveau d alcalinit sera grand L eau acide pH de moins de 7 0 est corrosive la plomberie aux appareils m nagers etc Un pH de 7 0 ou plus facilite l extraction de fer dans l eau voil pourquoi le filtre est con u pour augmenter le pH lorsqu il est au dessous de 7 0 L l ment du milieu filtrant con u pour l augmentation du pH est soluble c est dire qu il se dissipe lentement en m me temps qu il augmente le pH La vitesse laquelle cette dissolution s ex cute est proportionnelle au niveau d augmentation du pH requis et au taux de consommation d eau c d que plus le pH doit tre lev et plus le taux de consommation d eau est grand plus le taux de dissolution sera rapide Alors lorsque le pH est lev 8 2 ou plus comme c est requis lorsqu il y a pr sence de mangan se le taux de dissolution est encore plus grand Dans les pires circonstances l l ment MpH du milieu filtrant pourrait devoir tre remplac de deux quatre fois par ann e D un autre c t si le pH de l eau brute est 7 0 ou plus et s il n y a pas de mangan se pr sent le taux de dissolut
5. qu un adoucisseur devrait se retrouver lors de la planification d un nettoyage du syst me Avant de fermer la soupape d alimentation principale ou de mettre hors tension le syst me du puits priv et en pr paration pour l installation du filtre suivez ces directives 1 D connectez le tube d tirage de saumure du contenant de saumure et placez ce bout du tube dans un sceau de plastique d une capacit de cinq gallons contenant une solution d eau ti de et de 4 onces de nettoyant de min raux pour r sine 2 Avancez manuellement la minuterie du contr leur la position d tirage de saumure r f rez vous aux directives venues avec votre adoucisseur Laissez la solution ti de nettoyante de min raux se faire tirer au complet dans le lit de l adoucisseur Puis faites ceci imm diatement 3 Fermez la soupape d alimentation principale ou mettez hors tension la pompe et commencez l installation du filtre Le temps requis pour l installation du filtre servira aussi pour laisser la r sine souill e de fer se nettoyer chimiquement 4 Apr s l installation du filtre et une fois avoir termin les derniers ajustements tel que remettre l alimentation d eau en marche et remettre le tube d tirage de saumure en bonne place repositionnez manuellement la minuterie de l adoucisseur la position du remous Laissez la minuterie ex cuter un cycle de r g n ration automatique Pendant le remous de l adoucisseur tout le fer nettoy de la r
6. 000 comme capacit de filtration du fer en ppm montant de fer filtrer par jour en ppm nombre de remous initier par p riode de douze jours Exemple Vous tes quatre dans votre famille il y a 8 ppm de fer dans votre eau et vous poss dez une piscine qui a besoin de 46 gallons d eau par jour 4 Membres dans la famille x75 Gallons d eau par personne 300 Gallons d eau pour la famille 46 Gallons d eau pour la piscine 346 Gallons d eau requis par jour x8 Concentration de fer 2 768 Montant de fer filtrer par jour en ppm 15 000 Capacit de filtration du fer en ppm 2 768 Montant de fer filtrer par jour en ppm 5 4 Fr quence du remous en jours Ces calcules indiquent que le remous doit tre initi chaque 5 4 jours Le contr leur peut initier le remous seulement chaque deux trois quatre six ou douze jours Il doit tre alors programm pour l intervalle la plus courte et la plus pr s du r sultat ce qui veut dire chaque quatre jours pour cet exemple Programmation du contr leur du remous R glage de la minuterie de 24 heurs INDICATEUR DU SERVICE PIGNON DE 24 HEURES POIGN E DE R G N RATION MANUELLE Pressez le bouton rouge pour d brayer de pignon de commande Tournez le grand cadran jusqu ce que l heure du jour actuelle pointe Pouss dans la direction oppos e du pointeur de l heure du jour Rel chez le bouton rouge pour enclencher de nouveau le pignon de commande R glage de la
7. Equipment Correctly Select the location of your filter tank with care Various conditions which contribute to proper location are as follows 1 Locate as close as possible to the water supply source 2 Locate as close as possible to a floor or laundry tub drain 3 Locate in correct relationship to other water conditioning equipment see Fig 1 2 or 3 Page 5 4 Filters and softeners should be located in the supply line before the water heater Temperature above 120 F damage filters 5 Do not install a filter or softener in a location where freezing temperatures occur Freezing may cause permanent damage to this type of equipment and will void the factory warranty 6 Allow sufficient space around the unit for easy servicing 7 If your water source is a community water supply a public water supply or you wish to bypass water used for a geothermal heat pump lawn sprinkling out buildings or other high demand applications refer to Fig 2 or 3 on Page 5 for additional equipment required Also refer to the NOTE following Step 10 on Page 6 The Importance of Your Pressure Tank The pressure tank found on private well systems becomes an integral part of the filter system by providing necessary mixing and contact time to the hydrocharged water While the iron filter will perform better on a standard air to water pressure tank it will perform satisfactorily on a captive air bladder pressure tank The bladder tank requires more car
8. REGENERATION KNOB drive gear Setting the Backwash Frequency The filter control features a skipper wheel with twelve numbered tabs and trip fingers Each represents one day of a twelve day schedule By adjusting the skipper wheel tabs the control can be programmed to backwash every second third fourth sixth or twelfth day according to your requirements RED POINTER The control is shipped with all the skipper wheel tabs pushed outwards You must push the tabs in toward the center of the wheel retracting the trip finger for each day that TAB backwashing is not required Rotate the skipper wheel until number 1 is at the pointer TRIP FINGER leave this tab out Moving clockwise round the skipper wheel adjust the remaining tabs using the following table as a guide RED TIME SKIPPER WHEEL SET BUTTON SHOWS EVERY OTHER DAY REGENERATION No of backwashes Skipper Wheel Tab Settings required in 12 days 1 2 3 4 5 6 7 8 9 10 11 12 1 four fin fin fin fin fin in fm in in im mn four in in fim im in im in im im in ts four in im in four in in im four in im in ag four fin in out in in Jout m in out in in Manual Regeneration Turn the manual regeneration knob clockwise This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration process The back centre knob will make one revolution in approximately t
9. clair en sortant du robinet mais devient rougeatre au repos cause des taches 2 L eau est rougeatre lorsqu elle sort du robinet 3 Il y a une perte de pression excessive venant du filtre 4 L eau semble laiteuse ou gaz e semble contenir de petites bulles A L hydro chargeur n aspire pas assez d air B La soupape de d tournement est ouverte C Le filtre initie le remous a des intervalles incorrects D ll y a une pr sence de mangan se ou de tannins E Le d bit est excessif pour votre mod le F La soupape de retenue se trouve entre l hydro chargeur et le r servoir sous pression interrompant le d bit d eau G Le cycle de pompage est trop court Le pH de l eau trait e est trop bas il devrait tre 7 0 ou plus haut il doit tre 8 2 lorsqu il y a du mangan se Le lit du filtre est satur par le fer pr cipit car la fr quence du remous n est pas assez grande Le filtre initie le remous des intervalles incorrects L lectrovalve fonctionne incorrectement ou le d bit pression du syst me est inad quat e Le lit du filtre est satur par le fer pr cipit Les soupape s d entr e et de sortie du contr leur ne sont pas compl tement ouverte s Du sable de la crasse ou de la boue s est retrouv dans le milieu filtrant du filtre Les mati res filtrantes du filtre ne sont pas bien classifi es Les mati res filtrantes du filtre se sont solidif
10. e du r servoir du filtre est de 20 psi SI la pression est au dessus de 50 psi un manod tenteur doit tre install sur la conduite d alimentation d eau en avant de l hydro chargeur figures 1 2 ou 3 page 4 2 Le taux de pompage de la pompe votre puits doit tre au moins de 5 gallons par minute gpm pour que l hydro chargeur op re efficacement En plus le taux de pompage doit tre gal au d bit du remous requis pour votre mod le voir les sp cifications la page 1 pour les d bits de remous Pour mesurer votre taux de pompage suivez ces instructions a Assurez vous qu il n y a pas de pompage d eau Ouvrez le robinet le plus pr s du r servoir sous pression Lorsque la pompe d marre fermez le robinet et mesurez combien de temps en secondes le r servoir prend redevenir plein lorsque le r servoir s arr te Cette mesure repr sente le temps de base b Avec un r servoir sous pression plein remplissez d eau un r cipient dont vous connaissez le volume et mesurez le nombre de gallons ayant coul avant que le r servoir se remette en marche Ceci mesure la r duction l tirage Divisez ce nombre par le temps de base et multipliez le r sultat par 60 pour obtenir le taux de pompage en gallons par minute gpm Pour faciliter vos calcules ins rez les mesures dans la formule suivante REDUCTION L TIRAGE TEMPS DE BASE x 60 gals secondes TAUX DE PPOMPAGE gpm EXEMPLE La REDUCTION L TIR
11. fr quence du remous contr leur du filtre comprend un disque saccad avec douze onglets num rot s et doigts de d clenchement Ensembles ils repr sentent un calendrier de douze jours En ajustant les onglets du disque saccad le contr leur peut tre programm pour initier le remous chaque deuxi me troisi me quatri me sixi me ou douzi me jour d pendant de vos besoins POINTEUR ROUGE nee 2 ONGLET A l exp dition les onglets du disque sur le contr leur sont tous ressortis Vous devez repousser les onglets dans le disque en retirant le doigt de d clenchement lorsqu il n y a pas de besoin DOIGT DE D CLENCHEMENT pour le remous pendant leur jour respectif Tournez le disque saccad jusqu ce que le num ro 1 soit align avec le pointeur et lassez cet onglet ressorti Continuez autour du disque dans le sens des aiguilles et ajustez le reste BOUTON ROUGE DISQUE SACCADE AFFICHE LA des onglets en laissant le tableau vous guider DU R GLAGE DE R G N RATION CHAQUE L HEURE PROCHAIN JOUR 10 de r g n ration REGLAGES DES ONGLETS DU DISQUE SACCADE requise pendant 12 jours Sortie Pouss Pouss Pouss Pouss Pouss Pouss Pouss Pouss Pouss Pouss Sortie Pouss Pouss Pouss Pouss Pouss ss Pouss Pouss Pouss Pouss Pouss Sortie Pouss Pouss Pouss Sortie Pouss Pouss Pouss Sortie Pouss Pouss Pouss Sortie Pouss
12. laissez l appareil terminer son cycle par soi m me Figure 5 Conduite du drain de l quipment Drain de vidange Figure 6 Orifice de succion TEN Vis d adustement du d bit d eau 9 R glez I hydro chargeur en suivant ces directives A Ouvrez le robinet le plus pr s jusqu ce que la pompe d marre puis fermez le robinet B Placez votre doigt au dessus de l orifice de succion figure 7 Une faible succion devrait tre d tect e pendant une p riode minimale de 20 secondes ou pendant environ le tiers de la dur e du cycle de la pompe d pendant duquel soit le plus long C Si la dur e de la succion est trop courte augmentez la en tournant la vis d ajustement du d bit d eau figure 6 dans le sens des aiguilles Pour diminuer cette dur e tournez la vis dans le sens inverse des aiguilles D R p tez les tapes de C jusqu ce que la succion soit r gl e ad quatement Lorsque la succion est trop longue l eau froide peut avoir une apparence embrouill e cause de l exc s d air pr sente dans le syst me Cette condition est souvent attribu e avec les r servoirs sous pression comprenant une vessie natatoire Dans les cas extr mes l exc s d air peut nuire la performance du syst me ce qui n cessite alors l installation d un purgeur d air par exemple du type Braukman la bonne place Figure 6 10 Traces de fer Assurez vous que le d tournem
13. nombre et le type de connexions requises Les diagrammes de syst mes typiques dans ces instructions figure 1 2 ou 3 page 4 peuvent vous aider N B Si le syst me de tuyauterie sert de mise terre l alimentation lectrique la continuit du courant doit tre maintenue en installant une tresse de mise terre chaque endroit o des tuyaux de plastique non conductibles sont install s dans le syst me 6 Si vous avez une pompe pression constante ou un syst me de pompage VFD vous devrez ajouter un ensemble de pompe air et caisse de respiration no 978003 pour 115 volts et ou no 978004 pour 230 volts Le contr leur d bitm trique no 79980 sera aussi requis pour faire d marrer la pompe air Voir la figure 4 pour un diagramme d installation Section 3 L installation Il est tr s important de suivre la bonne s quence d installation d quipements de traitement d eau R f rez vous aux diagrammes suivants pour votre alimentation d eau particuli re N B La prise d air de Braukman n est pas approuv e pour l usage dans l Etat de Wisconsin Un air approuv pour arroser la prise d air de et ou de r servoir devrait tre utilis e avec cette application dans l Etat de Wisconsin Purgeur d air Figure 1 Eau adoucie sand fer Vers le cont lleur de la pompe Le Eau brute du puits Interrupteur de pression Hydro chargeur R servoir Sous pression Vidange Adoucisseur Filtre de fer
14. pas correctement le probl me doit tre corrig avant l installation de votre filtre de fer Ce que vous devez vous souvenir en planifiant votre installation 1 Toutes proc dures d installation doivent se conformer aux codes municipaux ou provinciaux gouvernant les installations de plomberie 2 L eau doit passer par l hydro chargeur le r servoir sous pression et le filtre sinon r f rez vous aux directives sp ciales concernant une installation courant divis la Page 6 Le syst me peut fonctionner incorrectement si ces instructions sont ignor es 3 Si le filtre doit trait l eau d un arrosoir ext rieur d une piscine d un chauffeur refroidisseur g othermique ou de tout autre appareil activit semblable le mod le de ce filtre doit tre un des plus grands disponibles pour accommoder les demandes plus grandes de d bit caus es par ces applications Le taux de pompage de la pompe votre puits doit tre suffisant pour accommoder les demandes de ces applications en plus du remous requis par le filtre Consultez votre revendeur pour une alternative si le taux de pompage est insuffisant 4 Souvenez vous que la bouche d entr e du filtre est li e au tuyau d alimentation d eau c d re oit l eau de la pompe et que la bouche de sortie du filtre envoi l eau vers le chauffe eau 5 Avant de commencer l installation il est sugg r d tudier le syst me de tuyauterie d j en place pour d terminer la grandeur le
15. retrouv s dans les alimentations d eau le fer soluble connu aussi comme l eau claire ou l eau ferreuse le fer pr cipit connu aussi sous le nom d eau rouge ou fer ferrique et le fer bact rien connu aussi sous le nom de bact ries ferrugineuses Il n y a pas de limite maximale observ e de concentration de fer pouvant tre filtr e cependant le choix d un mod le de filtre doit tre fait soigneusement si votre eau a une forte concentration de fer a un pH bas et ou contient du mangan se Le mangan se Mn La pr sence de mangan se peut causer des ennuis m me un filtre de fer non chimique Une concentration de mangan se de 0 05 ppm est suffisante pour produire des t ches brun tres ou noires L habilet du filtre enlever le mangan se d pends de la concentration retrouv e ainsi que le pH de l eau Le mangan se a tendance s encro ter au dessus du lit du filtre le laissant incapable d augmenter le pH et par cons quent inefficace pour enlever le fer ou le mangan se Ce dernier par contre peut tre pr cipit au fond du lit du filtre lorsque le pH est augment Pour accomplir ceci un m dia sp cial d nomm M contenant une quantit additionnelle de l l ment qui augmente le pH additionneur MpH peut tre fourni Le m dia de type M n est que pour les applications o la concentration de mangan se est pas au dessous de 1 5 ppm et le pH est de 6 0 ou plus Lorsque le pH
16. sine sera rinc et rejet dans le drain de vidange Il est pr f rable apr s le nettoyage chimique de l adoucisseur de r g n rer le syst me deux fois pour s assurer que toute capacit perdue cause du fer est r tablie Chauffe eau Si le chauffe eau a t expos au fer et a la duret de l eau pour une longue p riode de temps il se peut que la seule solution pour pr venir la contamination continue de cette source soit de remplacer compl tement le chauffe eau Apr s avoir compl t l installation du filtre de fer non chimique nettoyez le chauffe eau de la fa on suivante 1 Coupez le courant lectrique allant au chauffe eau et fermez la soupape d entr e du chauffe eau 2 coulez l eau chaude hors du chauffe eau au complet Ouvrez la soupape d entr e du chauffe eau et laissez le se remplir d eau sans fer Continuez ce rin age jusqu ce que l eau s coulant au drain devienne claire 3 Si apr s environ trente minutes de rin age l eau n est toujours PAS claire arr tez de rincer le chauffe eau Remplissez de nouveau le chauffe eau et ajoutez environ 2 gallon d eau de javel dans l embouchure du haut du r servoir Laissez la solution d eau de javel mijoter dans le chauffe eau entre 20 et 30 minutes Rincez le r servoir une fois de plus jusqu ce que l eau allant au drain devienne claire N B Si l eau n arrive pas devenir claire apr s environ 10 minutes le chauffe eau devra probablement tre remplac
17. syst me Plus de 90 des probl mes qui affectent l efficacit du filtre de fer non chimique peuvent tre identifi s en moins de 9 minutes en suivant cette liste de diagnostique Commencez l tape 1 puis suivez chaque tape dans la s quence pr sent e pour assurer que les proc dures de diagnostique sont ex cut es correctement 1 V rifiez si l installation est bien faite a L hydro chargeur est il install entre la pompe du puits et le r servoir sous pression avec la fl che point e vers le r servoir sous pression b Y a t il 6 pouces au minimum de tuyau droit chaque bout de l hydro chargeur sans pi ces de rattachement c La soupape de retenue si pr sente est elle bien plac e entre l hydro chargeur et la pompe d Le tuyau allant du r servoir sous pression au filtre est il connect la bouche d entr e de la soupape de contr le Le tuyau allant du filtre au chauffe eau est il connect la bouche de sortie de la soupape de contr le e La conduite allant au drain de vidange est elle du bon diam tre La taille de la conduite doit tre ad quate pour ne pas que la contre pression r duise le d bit du remous au dessous du minimum requis pour le mod le install Voici quelques exemples de diam tres minimaux typiques de conduite du drain l 2 po int rieur lorsque le drain de vidange est a moins de 15 pieds de l appareil et le port de d charge du remous et au dessous de la soupape de contr le Il
18. the sacrificial rate is even greater Under the most severe conditions the MpH component of the media may have to be replenished two to four times per year On the other hand if the raw water pH is 7 0 or above and no manganese is present the sacrificial rater is very slight Tannins Humic Acid Tannins also know as humic acid which are present in some supplies are the result of decaying vegetable matter If the tannin concentration is above approximately 0 5 ppm it will form a sticky coating on the media thus rendering it incapable of filtering the iron A chemical free iron filter is not recommended for this situation If the tannin concentration is less than 0 5 ppm a chemical free iron filter may be installed Hydrogen Sulfide H S Hydrogen sulfide often referred to as sulfur is easily detectable by its objectionable rotten egg odor Sulfur corrodes iron brass copper and silver A chemical free iron filter is not recommended when hydrogen sulfide is the only water problem although it is capable of removing sulfur concentrations of up to 2 to 3 ppm Whenever hydrogen sulfide is present backwashing must be performed at more frequent intervals and the pumping system MUST include a standard air to water pressure tank with an air relief valve Check Your Water Pressure and Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage 1 Minimum water pressur
19. 5 8 po int rieur lorsque le drain de vidange est moins de 15 pieds de l appareil et le port de d charge du remous et l g rement au dessus de la soupape de contr le lll po int rieur lorsque le drain de vidange est 25 pieds de l appareil ou lorsque le drain est plus haut que l appareil La conduite allant au drain a t elle t tordue Une conduite tordue et coch e doit tre remplac e g La conduite allant au drain est elle install e de fa on qu elle g le lors des temp ratures froides h Sile syst me comprend un r servoir sous pression air eau standard est il quip du contr leur de volume d air de fond requis purgeur d air et fonctionne t il correctement Une bonne installation de ce genre de r servoir sous pression doit avoir l entr e de la pompe plus lev e que la sortie allant au service mh 2 V rifiez le pH et la concentration de fer et de mangan se dans l eau trait e Le pH de l eau trait e est il au dessous de 6 7 ou 8 2 lorsqu il y a trace de mangan se Si oui rechargez le filtre avec l l ment MpH et v rifiez qu il n y a pas de passage pr f rentiel de l eau dans le filtre channeling 3 V rifiez le taux de pompage N utilisez pas une courbe du taux de pompage pour obtenir cette valeur Suivez les directives de la page 3 Le taux de pompage mesur est il plus bas que le d bit du remous du filtre Si oui augmentez le taux de pompage en commen ant par r duire la pression de se
20. AGE est de 6 gals le TEMPS DE BASE est de 53 secs donc TAUX DE PPOMPAGE est gal 6 gals 53 secs x 60 6 8 gpm Voir les sp cifications a la page 1 pour les d bits minimaux N B Si votre taux de pompage n est pas ad quat n installez pas votre filtre avant que ce probl me soit r gl Identifiez votre quipement de traitement d eau correctement Choisissez l emplacement de votre r servoir du filtre avec soin Les conditions suivante doivent tre prise en consid ration Placez le aussi pr s que possible de la source de l alimentation d eau Placez le aussi pr s que possible d un drain de plancher ou de la laveuse Placez le dans le bon ordre avec les autres appareils de traitement d eau voir figures 1 2 et 3 Les filtres et les adoucisseurs doivent tre plac s avant le chauffe eau dans la ligne d alimentation d eau Les temp ratures au dessus de 120 F endommagent les filtres et les adoucisseurs et annulent la garantie de la manufacture 5 N installez pas de filtre ou d adoucisseur l ou il peut y avoir des temp ratures de gel Celles ci peuvent endommager de fa on permanente ce type d quipement et annule la garantie de la manufacture Laissez assez d espace libre autour de l appareil pour faciliter l entretien Si votre source d alimentation d eau est une source communautaire ou publique ou si vous d sirez d tourner l eau utilis e pour une pompe chaleur g othermique un arrosoir pour pelouse des b timen
21. DUROclean IF Chemical Free Iron Filter OPERATION MANUAL PLEASE NOTE To ensure your unit is operating correctly and to protect your warranty please be sure to familiarize yourself with the maintenance instructions on page eleven of this manual 51633EF Rev 11 09 DUROclean IF Item Model No Media Pipe Size Flow Rates USGPM Fiberglass Tank Iron Removal Shipping No Description Cu Ft Inches Continuous Peak Backwash Size Inches Capacity ppm Weight Lbs 3230 DIF75 15 3 4 2 5 3 5 8x47 22 500 110 3240 DIF75M 15 3 4 2 5 3 5 8x47 22 500 110 3231 DIF10 1 3 4 3 6 4 9 x 48 30 000 145 3241 DIF1OM 1 145 3232 DIF15 1 5 3 4 4 10 5 10 x 54 60 000 250 3242 DIFISM 15 250 3233 DIF20 2 365 3243 DIF20M 2 1 5 15 7 12 x 52 90 000 365 Peak flow rates intended for intermittent use only 10 minutes duration or less For satisfactory operation pumping rate of well system must equal indicated backwash flow rate Models ending in M are required when raw water has up to 1 0 mg l of manganese or when pH is below 7 0 Over a period of time it may become necessary to add more media to the unit An ML 1 media loader is available Adding media is necessary only when water has low pH or manganese is present The manufacturer reserves the right to make product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured products or
22. Instructions To Calculate Backwash Frequency Normal Applications Backwash frequency for households with average water use can be determined using the following guides The guide cannot be used if the filtered water supplies a swimming pool geothermal pump outside spigots or other high water demand devices or activities If your application includes any of the foregoing refer to the paragraph on Special Applications below 1 Locate the box intersected by the number of people in your family and the parts per million ppm of iron in your water if your ppm is between two numbers on the guide use the higher number 2 The number in the box represents how many times your filter has to backwash in a twelve day schedule Iron Content ppm Example You have four in the family and 8 ppm of iron Refer to the guide and locate the box intersected by four in the family and 8 ppm of iron The figure supplied is 2 This means your filter control should be programmed to backwash twice in twelve days that is every sixth day If the figure had been 3 it would mean 3 backwashes in twelve days or every fourth day To Calculate Backwash Frequency Special Applications To ensure adequate reserve capacity and prevent loss of water pressure between backwashes the figure of 15 000 not the full 30 000 ppm capacity is used to calculate backwash frequency Determine your backwash frequency as follows 1 Estimate daily iron removal requirement
23. Lave vaisselle Consultez votre mode d emploi et suivez les directives du fabricant R servoirs pour chasse d eau des toilettes Avant de commencer l installation du filtre versez de 4 6 onces du nettoyant de min raux pour r sine Pro Rust Out ou d acide chlorhydrique inhib dans les r servoirs pour chasse d eau et les bols de toilette puis laissez mijoter Lorsque l installation est compl t e ex cutez la chasse d eau plusieurs reprise avec l eau sans fer Si les d p ts ou les t ches de fer sont encore visibles recommencez cette proc dure jusqu ce que l eau devienne claire Section 5 Directives du remous Pour calculer la fr quence du remous applications normales La fr quence du remous pour demeures ayant un usage d eau ordinaire peut tre d termin e partir de ces r gles Celles ci ne peuvent tre utilis es si l eau filtr e sert alimenter une piscine une pompe g othermique des robinets ext rieurs ou tout autre appareil ou activit grande demande de d bit Si vous utilisez une application de ce genre r f rez vous au paragraphe ci dessous pour Applications sp ciales 1 Trouvez la case l intersection du nombre de Nombre de Concentration de fer ppm membres dans votre famille et de la dans la famille concentration de fer en parties par million ppm dans votre demeure si votre concentration se trouve entre deux chiffres du tableau utilisez le plus grand des deux chiffres
24. Pouss Sortie Pouss Pouss Sortie Pouss Pouss Sortie Pouss Pouss R g n ration manuelle Tournez la poign e de r g n ration manuelle dans le sens des aiguilles Ce simple mouvement de la poign e enclenche le disque de programmation pour d marrer le cycle de r g n ration La poign e centrale arri re prendra environ trois heures pour faire un tour complet puis s arr tera dans la position indiqu e sur le diagramme La dur e r elle du remous est de 14 minutes En tout tat de cause l eau filtr e devient disponible aussit t que le rin age a fini de couler de la conduite du drain du filtre L Entretien Votre filtre de fer non chimique a besoin de quelques proc dures d entretien pour assurer qu il conserve une performance optimale et qu il continue fournir une eau saine pour plusieurs ann es sans probl mes Les directives suivantes devraient tre suivies une ou deux fois par ann e ou plus dans des conditions plus rigoureuses 1 V rifiez le taux de pompage du syst me ne vous r f rez pas la courbe du pompage pour obtenir cette valeur Suivez les directives la page 3 Si le taux de pompage mesur est plus bas que le taux de d bit du remous du filtre consultez le Guide de d pannage la page 10 2 Faites un test de pH de fer et de mangan se sur l eau brute et aussi l eau trait e pour assurer que vos conditions d eau n ont pas chang 3 Faites une inspection de l hydro chargeur et
25. abilet d augmenter le pH lorsqu il est au dessous du niveau neutre 7 0 ou plus bas am liore consid rablement l extraction efficace de fer de ce filtre L eau nette et filtr e peut ensuite passer dans les conduites d eau de votre demeure D pendant de l usage d eau et de la concentration de fer dans l eau brute un remous p riodique est requis pour d barrasser le filtre du fer accumul Le contr leur du filtre peut tre programmer pour initier le remous chaque deux trois quatre six ou douze jours selon le besoin les directives pour calculer la fr quence du remous et r gler le contr leur sont aux pages 7 et 8 N B Le remplacement du m dia pour l augmentation du pH sera requis p riodiquement selon le bas degr du pH de l eau brute la concentration de mangan se dans l eau brute et le montant d usage d eau La pression d eau Votre filtre eau est con u pour op rer sous une pression normale entre 20 psi et 50 psi La r g n ration et le d tournement automatique En manufacture la r g n ration des filtres eau est fix e 01h00 lorsque l usage d eau devrait tre son minimum Le cycle de r g n ration dure approximativement 15 minutes puis le service de filtration d eau est remis en marche Lors de la r g n ration l eau brute d tourne automatiquement le filtre si n cessaire Si possible vitez d utiliser l eau durant la r g n ration pour ne pas laisser l eau ferreuse de passer dans votre syst
26. ater periodic backwashing is required to flush the entrapped iron from the system The filter control can be programmed to backwash once every two three four six or twelve days as required instructions for calculating backwash frequency and setting the controls are on Pages 9 and 10 NOTE Replenishment of the media that raises pH will be required periodically depending on how low the raw water pH is the amount of manganese Mn present in the water and the water usage rate Water Pressure Your chemical free iron filter system is designed to operate under normal water pressures from 20 psi to 50 psi Backwashing and Automatic Bypass Your filter is factory set to backwash at 1 00 a m during a period of little or no water use The backwash cycle lasts approximately 15 minutes after which filtered water service is restored While backwashing is taking place raw water automatically bypasses the filter if required If possible avoid using water during backwashing to prevent iron laden water entering your household plumbing system New Sounds You will notice new sounds such as the hum of the timer as your filter operates During backwashing it will not be uncommon to hear water running to the drain Section 2 Before Installation Inspection and Handling Your Chemical Free Iron Filter Inspect the equipment for any shipping damage If damaged notify the transportation company and request a damage inspection Damage to cartons shou
27. ater department or plant operator and ask what the normal low system pressure is Set high pressure on pressure switch 2 to 3 psi lower than this figure NOTE Failure to set the pressure switch as described above will not allow proper closing of the solenoid valve during periods of low system pressure Section 4 Plumbing System Clean Up The following procedures are guidelines only but have proven successful in most instances Under no circumstances should any procedure outlined below be followed if contrary to the appliance manufacturer s instructions Should there be any questions concerning the advisability of performing a procedure it is strongly recommended the manufacturer s authorized service outlet be consulted prior to performing the procedure The plumbing system and water using appliances that have been exposed even for a short time to iron fouled water need to be cleaned of the precipitated iron that has collected in them or iron bleed staining will continue to be a problem Depending on the amount of iron in the water and the length of time the water system has been exposed to iron fouling select from the following procedures those that apply to the type of system and appliances that need to be cleaned to assure iron free water at the point of use Softener It isn t uncommon that a softener was installed in an effort to remove ferrous clear water iron from the water supply Typically a softener will remove some
28. ation grande demande d usage d eau apr s l installation de votre filtre ou avez vous omis d inclure telle application en d terminant la taille requise du syst me S il y a une haute demande d eau ne pouvant tre combl e re d terminez la taille requise du syst me l aide du taux de d bit continu lors du service 13 Garantie WaterGroup Companies Inc garantit que votre conditionneur neuf est fabriqu de mat riaux de qualit par une main d oeuvre professionelle Lorsque que celui ci est bien install et entrtenu vous tes assur de sa long vit et d un service sans souci Garantie Complete de Sept Ans sur Pi ces WaterGroup Companies Inc remplacera toute pi ce d fectuese l int rieur des 84 mois partir de la date de fabrication tel qu indiqu par le num ro de s rie seulement si l chec est d un d faut de mat riel ou main d oeuvre Le seule exception consistera si une preuve d achat ou d installation est fournie La garantie sera donc partir de cette date Garantie A Vie sur les R servoirs Min raux et R servoirs Saumure WaterGroup Companies Inc procurera un remplacement au r servoir min raux ou r servoir saumure tout acheteur qui poss de d j un r servoir qui cesse de fonctionner durant sa garantie Ceci seulement si le conditionneur est un tout temps op r selon les sp cifications requises et n est pas soumis au gel Clauses G n rales WaterGroup Compan
29. chargeur sans compter les pi ces de montage Assurez vous que la fl che d indication du courant sur l hydro chargeur pointe vers le r servoir sous pression et que l interrupteur de pression est situ entre l hydro chargeur et le r servoir sous pression tel qu indiqu aux figures 1 2 et 3 les cycles de la pompe peuvent devenir trop rapides si l interrupteur de pression est situ entre le puits et l hydro chargeur Si le syst me doit comprendre des soupapes de retenue elles doivent tre install es derri re l hydro chargeur et non entre l hydro chargeur et le r servoir sous pression N B Nous sugg rons d installer l hydro chargeur avec des raccords union aux deux bouts pour faciliter la d connexion et l entretien de l appareil Si l hydro chargeur est chauff retirez par avant la soupape de retenue en caoutchouc pour ne pas l endommager Pour les syst mes de tuyauterie plus vieux et incrust s il serait avantageux d installer un tamis en fourche Y avant l hydro chargeur pour emp cher le nez de l hydro chargeur de se faire bloquer par des incrustations 3 Coupez les conduites d alimentation d eau principale de fa on pouvoir rattacher la soupape de contr le la tuyauterie et installez la soupape de d tournement figure 5 Soudez la tuyauterie avec de l tain ou de l acier N exposez aucune pi ce de montage rattach e la soupape de contr le la chaleur du soudage car celle ci pourrait endommager des
30. criptions indiqu es ci haut sand tre oblig de modifier tout autre produit d j fabriqu ou de noter ces changements Section 1 Informations g n rales Lisez ce guide attentivement et suivez les tapes d installation dans l ordre indiqu Le fonctionnement de votre filtre de fer non chimique Le filtre de fer non chimique consiste en deux pi ces principales 1 Un hydro chargeur situ entre la sortie du puits et le r servoir sous pression ajoute une faible quantit d air l eau ferreuse lorsque la pompe est en marche R f rez vous aux figures 1 2 et 3 sur page 4 pour son emplacement N B Si votre pompe est de type pression constante ou variation de fr quence VFD I hydro chargeur inclus avec ce filtre ne fonctionnera pas correctement Une pompe air et une caisse de respiration devront tre ajout s au syst me pour faire introduire lair requis dans la circulation d eau du syst me R f rez vous la page 4 pour plus d information 2 Un filtre de type en remous contenant un milieu filtrant sp cial causant au fer dans l eau hydro charg e de se pr cipiter travers le lit du filtre contrairement aux filtre oxydation chimique o le fer n est captur qu la surface Ce proc d offre une capacit de retrait de fer allant jusqu 30 000 ppm Votre filtre ajuste le pH automatiquement neutre ou plus haut lorsque l eau est acide sans l aide d un neutralisant d acide Cette h
31. de 51633EF Rev 11 09 DUROclean IF No No de mod le Mati res Taille du D bits USGPM Taille du r servoir en Taille du r servoir en Poids d item Description filtrantes pi tuyau Po En service En pointe Auremous fibre de verre Po vibre de verre ppm d exp dition Lbs 3230 DIF75 15 3 4 2 5 3 5 8x47 22 500 110 3240 DIF75 15 3 4 2 5 3 5 8x47 22 500 110 3231 DIF10 1 3 4 3 6 4 9x 48 30 000 145 3241 DIF10 1 3 4 3 6 4 9 x 48 30 000 145 3232 DIF15 1 5 3 4 4 10 5 10 x 54 60 000 250 3242 DIF15M 1 5 3 4 4 10 5 10 X 54 60 000 250 3233 DIF20 2 1 5 15 7 12 x 52 90 000 365 3243 DIF20M 2 1 5 15 7 12 x 52 90 000 365 Les d bits de p riode de pointe sont con us seulement pour les applications r sidentielles et pour un usage intermittent 10 minutes ou moins Pour une op ration ad quate le d bit de pompage au puits doit tre gal ou au dessus du d bit du remous indiqu Les mod les terminant en M sont requis lorsque l eau brute contient 1 0 mg l de mangan se ou lorsque le pH est dessous de 7 Apr s un certain temps il se peut qu un ajout de mati res filtrantes soit n cessaire Un chargeur de m dia ML 1 est disponible L ajout de mati res filtrantes est seulement n cessaire lorsque le pH est bas ou lorsqu il y a du mangan se pr sent dans l eau Le fabricant se r serve le droit d em liorer ses produits ce qui pourrait modifier les sp cifications et des
32. de la tuyauterie entre le filtre de fer et le r servoir sous pression pour assurer qu ils ne sont pas bouch s de fer brut Si c est le cas le d bit d eau vers la demeure sera r duit Le r sultat est alors une r duction d eau disponible pour le remous du filtre ce qui nuit l op ration du syst me 4 Le r servoir sous pression air eau faites couler et rincer votre r servoir p riodiquement pour pr venir contre l accumulation de fer pr cipit au fond du r servoir 5 R servoir vessie natatoire v rifiez p riodiquement que la pression la vessie natatoire reste 2 psi plus bas que la pression d enclenchement de la pompe 6 V rifiez l hydro chargeur pour que l aspiration d air soit ad quate et au bon moment au tiers du cycle de la pompe ou chaque 20 secondes celui qui est le plus long 7 Pour les applications ayant un pH bas une concentration de mangan se ou de sulfure d hydrog ne consultez votre revendeur local pour obtenir des directives sp ciales pour maintenir l efficacit et la bonne op ration de votre appareil 8 Nettoyez p riodiquement le purgeur d air l aide de vinaigre ou d un acide faible pour assurer qu il retire proprement l air en exc s Le r servoir du filtre peut tre nettoy l aide d une solution savonneuse faible 10 Ne jamais exposer l appareil des temp ratures de gel Notes d entretien 11 Section 6 Guide de d pannage PROBLEME CAUSE SOLUTION 1 L eau est
33. diagramme du c blage 4 Tous codes et r glements gouvernementaux concernant l installation de ces appareils doivent tre observ s V rifiez vos codes lectriques locaux ou consultez un lectricien certifi Figure 4 Eau douce sand fer Pr filtre de5 Eau sans fer microns H i _ Purgeur d air Sortie I Pompe a air Entr e St rilisateur UV Entr e Sortie Filtre Big Blue a l entr au domicile Vidange Mascontrol Vidange Alimentation d eau de la pompe VFD Adoucisseur Filtre de fer Caisse de respiration Pompe au puits 1 Fermer le courant d eau l alimentation principale Arr tez la pompe et videz le r servoir sous pression si votre eau est aliment e par un puits priv e Assurez vous qu il n y a plus aucune pression dans le syst me en ouvrant le robinet le plus pr s et le laissant s couler Fermer l alimentation du chauffe eau lectrique ou carburant Installation des m dias lorsque n cessaire e D connectez la soupape du r servoir de min raux e Bouchez temporairement le bout ouvert du tuyau montant pour assurer qu il n y ait pas de r sine ou de gravier qui tombe dans la distribution e Remplissez le r servoir d eau jusqu au quart pour prot ger la distribution lors de l installation du gravier Ajouter le lit de gravier de support ainsi que les m dias de l adoucisseur au r servoir lentement et doucement de fa on a ce que c
34. e required at the filter tank inlet is 20 psi IF pressure is over 50 psi a pressure reducing valve must be installed in the water supply line ahead of the hydrocharger Fig 1 2 or 3 Page 5 2 The pumping rate of your well pump must be at least 5 gallons per minute gpm for satisfactory operation of the hydrocharger In addition the pumping rate must equal the required backwash flow rate of your model see Specifications on Page 1 for backwash flow rates To measure the pumping rate of your pump follow these instructions a Make certain no water is being drawn Open spigot nearest pressure tank When pump starts close spigot and measure time in seconds to refill pressure tank when pump shuts off This figure represents cycle time b With the pressure tank full draw water into a container of known volume and measure the number of gallons drawn until the pump starts again This is draw down Divide this figure by cycle time and multiply the result by 60 to arrive at the pumping rate in gallons per minute gpm To aid in your calculation insert the data in the following formula DRAW DOWN CYCLE TIME x 60 gals seconds PUMPING RATE gpm EXAMPLE DRAW DOWN is 6 gals CYCLE TIME is 53 secs then PUMPING RATE equals 6 gals 53 secs x 60 6 8 gpm See Specifications on Page 1 for minimum flow rates NOTE If your pumping rate is inadequate do not install your filter until the problem is solved Locate Water Conditioning
35. eater attached to the outlet port of the control valve e Is the drain line of adequate diameter Drain line must be sized to prevent back pressure from reducing backwash flow rate below minimum for the model installed Typical examples of minimum drain line diameters are i 1 2 ID when drain is up to 15 ft from unit and backwash discharge point is lower than the control valve ii 5 8 ID when drain is up to 15 ft from unit and backwash water discharge point is slightly higher than the control valve iii 3 4 ID when drain is 25 ft away and or drain is installed overhead Has the drain line been kinked A kinked drain line must be replaced g Is the drain line installed in a way that it will freeze in cold weather h Ifthe system incorporates a standard air to water pressure tank does it have the required deep well air volume control air release valve and is it functioning Proper installation of this type of pressure tank should have inlet from pump higher than outlet to service sh 2 Check pH Iron and Manganese Content of Treated Water Is the treated water pH reading less than 6 7 8 2 when manganese is present If yes replenish the media with MpH adder and check the bed for channelling 3 Check Pumping Rate Do not refer to a pumping rate curve for this data Follow the instructions found on Page 3 Is the measured pumping rate less than the backwash rate of the filter If yes increase the pumping rate by f
36. eater has been exposed to both iron and hardness for a long period of time replacement of the heater tank may be the only solution to prevent continued staining originating from this source After completing the installation of the chemical free iron filter system clean the water heater by following these instructions 1 Shut off energy supply to water heater and close heater inlet water valve 2 Drain hot water tank completely Open inlet water valve allowing heater tank to be refilled with iron free water Continue flushing until water runs clear to drain 3 If after approximately 30 minutes flushing water does NOT clear terminate flushing operation Refill hot water heater with water and pour approximately 1 2 gallon of household bleach into top of heater tank Allow bleach solution to stand in tank for 20 to 30 minutes Flush tank again until water is clear at drain Turn energy supply on NOTE If water does not clear in approximately 10 minutes water heater should probably be replaced Dishwasher Consult owner s handbook and follow manufacturer s instructions Toilet Flush Tanks Prior to commencing installation of the filter system pour 4 to 6 ounces of resin mineral cleaner Pro Rust Out or inhibited muriatic acid into flush tanks and bowls and let stand When installation is completed flush toilets several times with iron free water If iron deposits or stains remain repeat procedure until clear Section 5 Backwashing
37. eful adjustment of the hydrocharger and careful location of the air relief valve see Fig 7 and 8 Page 7 If cycle time on pumping system is less than 30 seconds and severe operating conditions exist flow pH high iron manganese and small concentrations of sulfur a standard air to water pressure tank with an air relief valve must be used if bladder tank is already in place do not remove it install the air to water pressure tank between the hydrocharger and the bladder tank NOTE If your pressure tank or any part of your water system is not functioning properly corrective action must be taken before installation of your iron filter Facts to Remember When Planning Your Installation 1 All installation procedures must conform to local and state plumbing codes 2 All water must pass through the hydrocharger pressure tank and the filter or refer to the special instructions for a split stream installation on Page 7 System may malfunction if these instructions are ignored 3 If lawn sprinkling a swimming pool geothermal heating cooling or water for other devices activities is to be treated by the filter a larger model filter must be selected to accommodate the higher flow rate demands of these items The pumping rate of the well pump must be sufficient to accommodate these items plus the backwash requirement of the filter Consult your dealer for alternative instructions if the pumping rate is insufficient 4 Remember tha
38. ent est ferm et que les bouches d entr e et de sortie sont compl tement ouverte V rifiez s il y a des fuites 11 R glez l heure du jour et la fr quence du remous voir page 10 Programmation du contr le du remous N B Apr s la mise en marche initiale le filtre peut prendre plusieurs jours avant de pouvoir retirer toutes dans l eau Cela est normale cause des caract ristiques naturelles des mati res filtrantes Installation du purgeur d air Braukman N B La prise d air de Braukman n est pas approuv e pour l usage dans l Etat de Wisconsin Un air approuv pour arroser la prise d air de et ou de r servoir devrait tre utilis e avec cette application dans l Etat de Wisconsin Le purgeur d air Braukman doit tre install e au plus haut point de la plomberie entre le r servoir de pression et le filtre voir figure 8 Veuillez noter que le purgeur d air Braukman A est mont sur un tuyau d extension B de quatre six pouces de long qui est install au coude C le plus lev de la tuyauterie Ceci permet au purgeur d air de mieux capturer l air en exc s caus par l hydro chargeur Si le purgeur d air Braukman est utilis avec un r servoir sous pression air eau installez le sur le c t du Le purgeur d air Braukman doit tre install au point le plus lev de la tuyauterie entre le r servoir sous r servoir environ mi chemin du sommet comme indiqu dans le diagramme ci dessous OUVERT Purgeur d
39. ferrous iron until the resin bed becomes fouled to the extent that it will lose both hardness removal capacity and the limited capacity for iron removal This is the condition to expect a softener to be in when planning a system clean up Prior to closing the main supply valve or turning power off to private well system and preparatory to installing the filter system do the following 1 Disconnect brine draw line from the brine cabinet and place the loose end into a five gallon plastic pail filled with a solution of warm water and 4 oz of resin mineral cleaner 2 Manually advance control timer to brine draw position refer to instructions provided with your softener Allow all the warm mineral cleaner solution to be drawn into mineral bed Then immediately 3 Close main water supply valve or turn power off to pump and proceed with filter installation During time required to install filter system iron fouled softener resin will be chemically cleaned 4 After filter installation is completed and final adjustments are made with the water turned on and brine draw tube reconnected manually reposition timer on softener to backwash position Allow timer to perform an automatic regeneration cycle During backwash of softener all iron cleaned from the resin will be washed down the drain It is advisable after chemically cleaning softener to regenerate system twice to fully restore capacity lost due to iron fouling Water Heater If the water h
40. ganese tends to coat the filter media rendering it incapable of increasing the pH and therefore ineffective in removing either the iron or the manganese Manganese however will precipitate in the filter bed when the pH is increased To accomplish this a special M type media that contains additional quantities of the pH raising component MpH adder can be provided The use of M type media is for applications where the manganese is not more than 1 5 ppm and the pH is 6 0 or higher When the pH is below 6 0 or higher When the pH is below 6 0 consult your dealer pH The pH of water measures its acidity or its alkalinity Water with a pH of less than 7 0 is acidic above 7 0 is alkaline and 7 0 is neutral The lower the pH value is below 7 0 the greater the acidity and the higher the pH value is above 7 0 the more alkaline Acidic water pH less than 7 0 is corrosive to pipes appliances etc A pH of 7 0 or higher facilitates iron removal which is why the filter is designed to increase the pH when it is less than 7 0 The pH increasing component of the media is sacrificial That is it slowly dissolves during the process of increasing pH The rate at which this occurs is proportional to the pH increase and the water consumption rate i e the greater the pH increase and the water consumption the greater the sacrificial rate Thus when the pH is increased to 8 2 or more as is necessary when manganese is present
41. haque couche soit au bon niveau dans le r servoir e D bouchez le tube montant tout en y pla ant la soupape sur l embouchure puis visez la soupape au filetage du r servoir en fibres de verre et serrez pour bien la s curiser au r servoir N B assurez vous que le joint torique interne de la soupape s insert proprement par dessus le tuyau montant Vous pouvez appliquez de la graisse au silicone no 13691 ou tout autre lubrifiant de qualit alimentaire au joint torique s il en a besoin pour faciliter l installation du tuyau montant NE PAS utiliser des lubrifiants base de p trole car ceux ci peuvent causer des gonflements des joints toriques et d tanch it e Ladoucisseur est maintenant charg avec de la r sine adoucissante Il est recommand maintenant de remplir LENTEMENT le r servoir de l adoucisseur avec de l eau pour bien mouiller la r sine avant le d marrage Ceci permet la r sine d absorber l eau et l aide aussi se d barrasser des bulles d air empi g es Cela ensuite r duit le risque que la r sine se brasse et se d place par remous lors du d marrage 5 Coupez la ligne principale d alimentation d eau tel que n cessaire pour l installation de l hydro chargeur la tuyauterie entre la pompe au puits et le r servoir sous pression l hydro chargeur peut tre installer en position verticale ou horizontale Laissez un minimum de 6 pouces en ligne droite de tuyau chaque bout de l hydro
42. hree hours and stop in the position shown in the drawing Actual backwash time is 14 minutes In any event iron free water may be drawn after rinse water stops flowing from the filter s drain line 10 Maintenance Your chem free iron filter requires some minor maintenance to ensure optimum performance and years of trouble free clean water The following steps should be performed once or twice a year more often under harsh conditions 1 Verify the pumping rate of the system do not refer to pumping curve for this data Follow the instructions found on Page 3 If the measured pumping rate is less than the backwash rate of the filter see Page 12 Trouble Shooting Have your water tested for pH iron and manganese on both the treated and raw water to ensure your water conditions haven t changed Inspect the hydrocharger and the piping between the iron filter and the pressure tank to ensure they are not plugged with raw iron If the line becomes plugged the flow of water to the home will be reduced This will result in a reduction of water available for backwashing the unit which will inhibit operation of the system Air to water pressure tank periodically drain and flush your tank to prevent a build up of precipitated iron from forming in the bottom of the tank Bladder tank periodically check that the bladder air pressure remains at 2 psi lower than the cut in pressure of your pump Check the hydrocharger to ensure it is d
43. i es de sorte que l eau y passe sans filtration L hydro chargeur aspire trop d air Il y a trop de gaz dans l eau dioxyde de carbone sulfure d hydrog ne m thane 12 A V rifiez les ajustements de l hydro chargeur S il est impossible d ajuster pour obtenir une aspiration suffisante v rifiez le taux de pompage B Fermez la soupape de d tournement et ou faites les r parations n cessaires C R f rez vous au tableau des fr quences du remous dans le guide d op ration pour v rifier si l appareil est correctement r gl N augmentez pas la fr quence du remous moins que le tableau indique que c est n cessaire puisque les mati res filtrantes ont besoin d tre l g rement souill es de fer pour tre performance optimale Dans les cas les plus s v res de contamination de fer il se peut que le lit du filtre doive tre nettoy chimiquement consultez votre revendeur D Refaites l analyse de votre eau E Relisez la Section 2 Avant l installation la page 4 lorsque vous planifiez d installer le filtre F Installez la soupape de retenue une autre place G Augmentez la longueur du cycle de pompage Ajoutez de l l ment MpH dans le lit filtrant consultez votre revendeur a Re v rifiez le taux de pompage au puits et r parez ou remplacez au besoin b V rifiez s il y a une obstruction de la conduite au drain ou si elle est tordue ou c si le contr leur du d bit du drai
44. ies Inc n assume par cons quent aucune responsabilit pour dommage main d oeuvre ou d penses encourus suite un d faut ou chec rencontrer les termes de ces garanties pour cause de raisons hors de son autorit WaterGroup WATERGROUP INC WATERGROUP COMPANIES INC FRIDLEY MN REGINA SK CAMBRIDGE ON 1 800 354 7867 1 877 288 9888 www watergroup com
45. in filter media C Check well for these conditions D Filter bed not properly classified D Manually backwash to reclassify E Cementing or channelling of filter media E Prod stir filter bed to break up hardened layer increase backwash frequency to prevent recurrence 4 Milky or bubbly water appears to A Excess hydrocharger air draw A Check adjustment for duration of draw in excess of contain small bubbles one third pumping cycle see Section 3 Step 8 Page 6 B Excess gases in water carbon dioxide B May require cleaning or installation or air relief control hydrogen sulfide methane contact dealer 12 System Check List More than 90 of problems affecting the efficiency of a chemical iron free filter system can be identified in 9 minutes or less by following this diagnostic schedule Start with Step 1 then follow each step in sequence to ensure proper diagnostic procedures 1 Check for Proper Installation a Is the hydrocharger installed between well pump and pressure tank with arrow pointing toward pressure tank b Is there a minimum of 6 inches on the hydrocharger inlet and 6 inches on the outlet of the straight pipe free of pipe fittings c Is the check valve if used correctly located between the pump and the hydrocharger d Is the pipe from the pressure tank to the filter unit attached to the inlet port of the control valve Is the pipe from the filter unit to the water h
46. ion est minime Les tannins acide humique Les tannins connu aussi sous le nom d acide humique qui peuvent se retrouver dans certaines sources d eau sont le r sultat de la d composition de mati res v g tales Si la concentration de tannin surpasse approximativement 0 5 ppm une cro te collante se formera sur le milieu filtrant le rendant alors incapable de filtrer le fer Un filtre de fer non chimique n est pas recommand dans cette situation Si la concentration de tannin est au dessous de 0 5 ppm un filtre de fer non chimique peut tre install Le sulfure d hydrog ne HS Le sulfure d hydrog ne appel aussi soufre peut tre facilement reconnu par son odeur d ufs pourris d sagr able Le soufre corrode le fer le laiton le cuivre et l argent Un filtre de fer non chimique n est pas recommand lorsque la pr sence de soufre est le seul probl me de l eau bien qu il soit capable d enlever une concentration de soufre de 2 3 ppm Lorsqu il y a un pr sence de sulfure d hydrog ne le remous doit tre engager plus fr quemment et le syst me de la pompe DOIT comprendre un r servoir sous pression air eau standard avec purgeur d air V rifiez votre pression d eau et votre taux de pompage Deux conditions du syst me d alimentation d eau doivent tre v rifi es attentivement pour viter une op ration insatisfaisante ou des endommagements l quipement 1 La pression d eau minimale requise l entr
47. irst reducing the system operating pressure If the pumping rate is still too low replace the pump 4 Check Hydrocharger for Proper Air Draw Does air suction continue for 1 3 of the time the pump runs do not confuse with 1 3 of the pressure range Turn the water flow adjusting screw clockwise to increase the draw time and counter clockwise to decrease the draw time 5 Manually Stage Filter Control to Backwash Cycle Does a rush of air precede the backwash water out of the drain line If no proceed to Step 6 If yes the system is air logged Disconnect power from the pump and allow the system pressure to drop to zero through the filter drain line Restore power and rebuild system pressure Continue backwashing unit until the pump has completed two or three pressure cycles Stage control valve to the service position and check the hydrocharger draw time Adjust draw for 1 3 of pump cycle time 6 Determine Other Uses of Water in Addition to Normal Domestic Purposes e g geothermal heating or cooling swimming pool fill lawn irrigation farm animal watering etc Have any high demand water uses been added subsequent to the installation of the filter system or overlooked when originally sizing the system If a high demand situation exists resize the system using continuous service flow rate data 13 Guarantee WaterGroup Companies Inc guarantees that your new water conditioner is built of quality material and workmanship Whe
48. ld also be noted Handle the filter unit with care Damage can result if it is dropped or set on sharp uneven projection on the floor Do not turn the filter unit upside down NOTE If a severe loss in water pressure is observed when the filter unit is initially placed in service the filter tank may have been laid on its side during transit If this occurs backwash the filter to reclassify the media see Page 5 Step 7 Iron Fe Iron concentrations as low as 0 3 ppm will cause staining The iron concentration together with the flow rate demand and the consumption rate of the water determines the basic size of the filter system The higher these factors are the larger the required system The filter system is capable of filtering out the three main types of iron found in water supplies soluble iron also known as clear water or ferrous iron precipitated iron also known as red water or ferric iron and bacterial iron also know as iron bacteria There is no apparent upper limit of iron concentration for the filter but special care must be taken when selecting a filter model if your water has a combination of high iron very low pH and or manganese Manganese Mn The presence of manganese can be bothersome even for a chemical free iron filter As little as 0 05 ppm of manganese can produce a brownish or black stain The ability of the filter to remove manganese depends on its concentration and the pH of the water Man
49. lve Iron Free Water Iron Free Soft Water ans To 110V Outlet To Pump Controller f li Primary fi Pressure ri i Tank i ri Raw Well Water Pressure Switch Hydro Solenoid Valve Pressure Switch charger Secondary Pressure Tank Drain Softener Iron Filter Figure 3 Iron Free Water s i Air Release Valve Outdoor Iron Free Soft Water Raw out 2 H Water Drain Drain Pressure Tank E Raw Well Water Meter Softener Iron Filter Pressure Switch Hydro Solenoid Valve charger NOTE Before starting installation read Page 8 Plumbing System Clean Up for instructions on some procedures that may need to be performed first Installation of the Air Pump with Flow Control Switch Mascontrol as Power Source 1 Used when pressure switch and air pump are in alternate locations Also used on constant pressure or variable speed pump systems 2 Mascontrol acts as a flow control detecting flow 3 Connect the air pump to the Mascontrol receptacle See Mascontrol manual for wiring diagram 4 All government codes and regulations governing the installation of these devices must be observed Check your local electrical codes or contact a qualified electrician Figure 4 _ a RE FAIT aa Ta L awe IN Nl Installation Instructions 1 Shut off all water at main supply On a private well system turn off power to pump and drain pre
50. lve located between hydrocharger and pressure tank disrupting water flow G Lengthen pump cycle time Replenish MpH G Pumping cycle too short pH of treated component in media contact dealer water too low should be 7 0 or higher with manganese pH must be 8 2 2 Water is red when drawn from tap A Filter bed overloaded with precipitated iron A a Recheck well pumping rate and repair or replace due to insufficient backwash flow rate as required b Check for obstructions or kink in drain line or c for improper drain line flow controller see specs Upon correction of this problem if manually backwashing does not clear bed of iron filter bed may need chemical cleaning contact dealer B Filter bed backwashed at improper Refer to backwash frequency chart in operation intervals manual to ensure unit is set correctly Do not increase the backwash frequency unless required to based on the chart since the media needs to be somewhat iron fouled for best performance in more severe iron fouling cases filter bed may need chemical cleaning contact dealer C Solenoid valve malfunction or inadequate C Replace solenoid valve malfunction or inadequate supply system pressure flow rate supply system pressure flow rate 3 Excessive pressure loss through A Filter bed overloaded with precipitated iron A Refer to Section 2A above filter B Control inlet outlet valve s not fully open B Open valves C Sand silt or mud collecting
51. me de tuyauterie r sidentiel Bruits Le syst me met plusieurs sons normaux lorsqu en service tel que le ronflement de la minuterie Pendant la r g n ration il est normal d entendre l eau se vider dans le drain de vidange Section 2 Avant l installation L inspection et la manipulation de votre filtre de fer non chimique Examinez l quipement pour v rifier s il y a des endommagements caus s par l exp dition Si c est le cas mettez la compagnie de transportation au courant et demandez une inspection des dommages Les endommagements au carton devraient aussi tre not s Manipuler le filtre avec soin Il peut tre endommag facilement en l chappant au sol ou en le pla ant sur une surface pointue ou accident e Ne tournez pas l appareil l envers N B Si vous observez une perte s v re de pression d eau une fois le filtre install et mis en service il se peut que le r servoir du filtre ait t plac sur son c t lors du transport Si cela arrive initiez le remous du filtre pour re classifier le milieu filtrant voir section 3 page 7 Le fer Fe Une concentration de fer de 0 3 ppm est suffisante pour causer des t ches La concentration de fer en plus de la demande de d bit et du taux de consommation d eau d termine la taille de base requise du syst me de filtration Le plus ces facteurs sont hauts le plus cette taille sera grande Ce syst me est capable de retirer les trois types principaux de fer
52. n all the way Allow the unit to backwash until all the air and media fines are no longer showing at the drain This procedure may take several minutes so do not supply power to the timer until this procedure is complete During initial backwashings a small amount of fine white media may be observed in the drain water This is normal Now supply power to timer and allow the unit to finish the cycle on its own Set hydrocharger by following these steps A Open nearest faucet until pump starts then close faucet Figure 5 EQUIPMENT DRAIN LINE DRAIN Figure 6 SUCTION PORT E p i ti i WH p WATER FLOW ADJUSTING SCREW Figure 7 B Place a finger over suction port Figure 7 A slight suction should be detected for a minimum of 20 seconds or for approximately one third of pumping cycle whichever is greater duration turn counterclockwise C If suction duration is too short increase by turning water flow adjusting screw Figure 7 clockwise To decrease D Repeat Steps A through C until proper setting is obtained When the duration of the suction is too long cold water may have a milky appearance caused by excess air in system Correct this condition by reducing the duration of suction This condition is one commonly associated with bladder type pressure tanks In extreme cases excess air prevents the system from performing satisfactorily consequently it is essential to i
53. n est inad quat voir sp cifications Apr s avoir corrig le probl me si un remous manuel ne rince pas le lit du fer le filtre devrait tre nettoy chimiquement consultez votre revendeur B R f rez vous au tableau des fr quences du remous dans le guide d op ration pour v rifier si l appareil est correctement r gl N augmentez pas la fr quence du remous moins que le tableau indique que c est n cessaire puisque les mati res filtrantes ont besoin d tre l g rement souill es de fer pour tre performance optimale Dans les cas les plus s v res de contamination de fer il se peut que le lit du filtre doive tre nettoy chimiquement consultez votre revendeur C Remplacez l lectrovalve v rifiez les directives de la page 3 pour savoir le bon d bit bonne pression R f rez vous la Section 2A ci haut B Ouvrez le s soupape s C V rifiez le puits pour trouver la cause du probl me D Initiez le remous pour reclassifier les mati res filtrantes E Donnez quelques coups au lit ou brassez le pour briser les morceaux durcis du lit et augmentez la fr quence du remous pour ne pas que ceci se reproduise V rifiez les ajustements pour voir si l aspiration d air dure plus longtemps que le tiers du cycle de la pompe voir Section 3 tape 8 page 5 B Un nettoyage ou une installation d un contr leur de purge des gaz consultez votre revendeur Listes de v rifications du
54. n properly installed and maintained it will give years of trouble free service Seven Year Complete Parts Guarantee WaterGroup Companies Inc will replace any part which fails within 84 months from date of manufacture as indicated by the serial number provided the failure is due to a defect in material or workmanship The only exception shall be when proof of purchase or installation is provided and then the warranty period shall be from the date thereof Lifetime Guarantee on Mineral Tanks and Brine Tanks WaterGroup Companies Inc will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails within his her lifetime provided that the water conditioner is at all times operated in accordance with specifications and not subject to freezing General Provisions WaterGroup Companies Inc assumes no responsibility for consequential damage labor or expense incurred as a result of a defect or for failure to meet the terms of these guarantees because of circumstances beyond its control WaterGroup WATERGROUP INC WATERGROUP COMPANIES INC FRIDLEY MN REGINA SK CAMBRIDGE ON 1 800 354 7867 1 877 288 9888 www watergroup com DUROclean IF Filtres de Fer Non Chimique GUIDE D OP RATION N B Pour assurer la bonne op ration de votre appareil et pour conserver la garantie prenez soin de vous familiariser avec les directives d entretien situ es la page onze de ce gui
55. nk hydrocharger may be installed in a vertical or horizontal position Allow a minimum of 6 inches straight run of pipe on each side of hydrocharger excluding fittings Be certain direction of flow arrow on hydrocharger points toward pressure tank and pressure control switch is located on pressure tank side of the hydrocharger as in Fig 1 2 or 3 rapid cycling of pump may occur if pressure switch is located on well side If check valves are used they should be installed before the hydrocharger not between the hydrocharger and pressure tank NOTE It is advisable to install the hydrocharger with the unions at both ends to facilitate removal and inspection If heat is applied near hydrocharger remove rubber check valve to prevent damaging it On badly scaled older pumping systems it may be advantageous to install an optional Y strainer ahead of hydrocharger to prevent plugging hydrocharger nozzle with scale Cut main supply line as required to fit plumbing to control valve and attach the bypass valve Figure 5 Solder or solvent weld plumbing Do not apply heat to any fitting connected to control valve as damage may result to internal parts Check to be certain water supply pipe is connected to control valve inlet fitting and pipe connected to control valve outlet fitting is in direction of house service see Figure 6 NOTE If the installation is to be split streamed prior to the filter tank Figure 2 or is a public water suppl
56. nstall an air relief valve Such as Braukman in the proper location Make certain bypass is closed and inlet and outlet valves are fully opened Check for leaks Set time of day and backwash frequency see Page 10 Programming Backwash Controls NOTE After start up this filter may take several days to completely remove the iron This is normal because of the nature of the media Braukman Air Vent Installation NOTE The Braukman air vent is not approved for use in the State of Wisconsin An approved air to water tank and or air vent should be used with this application in the State of Wisconsin The Braukman Air Vent must be installed at the highest point of the plumbing between the pressure tank and filter see Figure 8 Please note that the Braukman Air Vent A is mounted on a four to six inch pipe extension B at the elbow C of the highest point This enables the vent to better collect any excess air created by the hydrocharger To use the Braukman Air Vent on an air to water pressure tank install it approximately halfway up the side of the tank as shown in the detailed drawing below Figure 8 c OPEN Braukman Braukman Air Vent Air Vent CLOSED See Figure 8 Pressure Pressure HI Tank Tank Diaphragm Air to Water 1 Air release cap must be loose or removed to allow air to escape from vent 2 Position indicator 3 Vent bushing 1 2 x 1 8 4 3 4 x 3 4 x 1 2 copper tee Special Instructions for S
57. pi ces internes de la soupape V rifiez que le tuyau d alimentation d eau est connect au raccordement de la bouche d entr e de la soupape de contr le et que le tuyau sortant de la bouche de sortie de cette soupape soit dirig vers le service int rieur de la demeure voir figure 6 N B Si un tamis en fourche Y doit tre install avant le filtre figure 2 ou si l installation est fait partir d un syst me d alimentation d eau publique figure 3 veuillez vous r f rer aux directives sp ciales de la page 7 5 D vissez les vis de pression pour retirer du corps de la soupape l assemblage de contr le du d bit allant au drain D vissez le raccordement entre le coude de la conduite du drain et l assemblage de contr le de d bit du drain Appliquez de l enduit d enrobage ou du ruban de t flon sur le filetage du raccordement R assemblez le tout au corps de la soupape en v rifiant que l assemblage de contr le du d bit du drain est bien ins r dans le corps de la soupape avant de remettre les vis de pression en place Rattachez une conduite de drain avec diam tre int rieur de 2 pouce au coude du drain ATTENTION Les vis de pression n ont besoin de d un faible serrement pour tenir le contr le en plastique du drain en place Un serrement trop fort peut endommager les raccordements Positionnez le boyau du drain au dessus du drain de vidange et s curisez le Laissez un espace entre les deux comme indiqu ou
58. plit Stream and Public Water Supply Type Installations For a split stream installation a secondary pressure tank must be installed as in Figure 2 On a public water supply installation a pressure tank must be installed as in Figure 3 It is recommended in both applications to use a standard air to water pressure tank with an air relief valve of a capacity that would be installed if the water system were a standard private well Also note that in both applications a normally closed solenoid valve is required Follow the standard installation instructions above with the following additions and modifications 1 Install pressure tank secondary pressure tank in Figure 2 as indicated by appropriate diagram 2 Install normally closed solenoid valve after water meter and after a line split for untreated water if there is one 3 On both types of installation install the hydrocharger between pressure tank secondary pressure switch on split stream type installations and normally closed solenoid valve 4 Install a pressure switch after the hydrocharger and wire it to the solenoid valve secondary pressure switch on split stream Set high pressure on pressure switch which controls opening and closing of solenoid valve to 3 psi lower than low pressure on primary pressure switch Example if primary pressure switch is set at 40 to 60 psi set secondary pressure switch high at 37 to 38 psi For public water supply installations contact your local w
59. prouv d tre efficaces dans la plupart des cas Ces proc dures ne devraient en aucune circonstances tre suivies si elles sont en d saccord avec les instructions du manufacturier des appareils ci dessous S il y a doute concernant l utilit de suivre une de ces proc dures il est fortement recommand de faire consultation avec un centre de service autoris par le manufacturier avant d ex cuter cette proc dure Le syst me de tuyauterie et les appareils m nagers se servant de l eau qui ont t expos s une eau souill e de fer m me pour une courte p riode doivent tre nettoy s de ce fer pr cipit qui s est accumul dans cet quipement sinon l coulement les t ches de fer continuera de causer des probl mes Choisissez parmi les proc dures suivantes celles qui s appliquent au type de syst me et d appareils qui doivent tre nettoy s d pendant de la concentration de fer dans l eau et de combien de temps le syst me a t expos l eau ferreuse pour assurer qu ils n ont plus aucune trace de fer lorsqu ils sont pr ts utiliser Adoucisseur Un adoucisseur d eau est souvent install dans le but d enlever le fer soluble eau claire de l eau courante L adoucisseur peut typiquement retirer une certaine quantit de fer jusqu ce que le lit de r sine devienne si souill qu il perd sa capacit d enlever la duret de l eau ainsi que sa capacit limit e de retirer le fer soluble C est dans cette condition
60. quivalent figure 6 pour emp cher l eau des gouts de siphonner en remous Le boyau du drain ne doit pas tre lev plus de 10 pi du sol D vissez les deux vis du couvercle du compteur afin de le soulever ATTENTION La programmation du compteur sera mal synchronis e si la poign e est tourn e trop loin ou si le moteur de commande n est pas permis de s arr ter soi m me avant de continuer la prochaine tape Si cela ce produit durant n importe quelle proc dure tournez la poign e dans le sens des aiguilles jusqu ce que le point blanc s aligne la fl che indicatrice de l heure du jour et que l appareil revienne la position du service Puis recommencez Mettez la pompe en marche Lorsqu il est exp di de l usine le filtre IF DUROclean est pr t mettre en marche le remous Ouvrez l alimentation d eau allant l appareil Commencez par l ouvrir lentement pour permettre aux bulles d air de s chapper du filtre avant de laisser l eau couler plein Laissez le remous en marche jusqu ce que tout l air ait chapp le filtre et qu il n y ait plus de traces de mati res filtrantes dans la conduite de vidange Cela peu prendre plusieurs minutes alors vitez de branchez le compteur avant que cette tape soit compl te Lors des premiers remous il se peut qu une fine trace de mati res filtrantes soit pr sente dans l eau allant au drain Cette trace est normale Maintenant placez la minuterie sous tension et
61. r et de la fourche la conduite l o l eau continue sans tre trait e s il y a telle fourche 3 Pour les deux types d installation installez l hydro chargeur entre le r servoir sous pression ou l interrupteur de pression secondaire sur les installations en fourche et l lectrovalve 4 Installez un interrupteur de pression la suite de l hydro chargeur et raccordez les fils l lectrovalve ou l interrupteur de pression secondaire sur les installations en fourche R glez la pression haute de l interrupteur de pression qui sert de contr le pour l ouverture et la fermeture de l lectrovalve 3 psi plus bas que le r glage de pression basse sur l interrupteur de pression primaire Exemple si l interrupteur de pression primaire est r gl de 40 60 psi r glez la pression haute de l interrupteur secondaire de 37 38 psi Pour les installations alimentation d eau publique contactez votre centre de distribution d eau local ou l op rateur de l usine et demandez quelle est la pression basse normale du syst me de distribution R glez la pression haute de l interrupteur de pression 2 ou 3 psi plus bas que le montant obtenu ci haut N B Si l interrupteur de pression n est pas r gl comme indiqu ci haut l lectrovalve sera incapable de se fermer lors des p riodes de basse pression Section 4 Nettoyage du syst me de tuyauterie Les directives suivantes ne servent que de guide g n ral bien qu elles aient
62. rawing air properly and for the correct amount of time 1 3 of the pump cycle time or 20 seconds whichever is greater For applications with low pH manganese or hydrogen sulfide consult your local dealer for specific instructions to maintain the efficiency and operation of your filter Periodic cleaning of the air vent assembly with mild acid or vinegar will ensure that it continues to vent excess air properly The filter tank can be cleaned with a mild soap solution Never subject the unit to freezing Maintenance Notes 11 Trouble Shooting Guide PROBLEM CAUSE CORRECTION 1 Water is clear when drawn turns A Insufficient air drawn by hydrocharger A Check hydrocharger adjustment If unable to adjust for red upon standing stain producing long enough draw check pumping rate B Bypass open or leaking B Close bypass valve and or repair as necessary C Filter bed backwashed at improper C Refer to backwash frequency chart in operation intervals manual to ensure unit is set correctly Do not increase the backwash frequency unless required to based on the chart since the media needs to be somewhat iron fouled for best performance in more severe iron fouling cases filter bed may need chemical cleaning contact dealer D Recheck water analysis D Presence of manganese or tannins E Re read Sec 2 Facts to Remember When Planning E Flow rate excessive for model Your Installation Page 4 F Relocate check valve F Check va
63. rvice du syst me Si le taux de pompage demeure toujours trop bas remplacez la pompe 4 V rifiez que l hydro chargeur aspire l air ad quatement La succion dure t elle pour le tiers du temps que la pompe est en marche ne pas confondre avec le tiers de l intervalle de pression Tournez la vis pour ajuster le d bit dans le sens des aiguilles pour augmenter la dur e d aspiration ou dans le sens inverse des aiguilles pour diminuer la dur e 5 Avancez manuellement le contr leur du filtre au cycle du remous Y a t il une vol e d air sortant de la conduite allant au drain avant la d charge d eau du remous Si non sautez l tape 6 Si oui il y a de l air comprim prise dans votre syst me Mettez la pompe hors tension et laissez la pression du syst me descendre z ro travers la conduite du drain du filtre tablissez de nouveau la tension la pompe et laissez la pression se r tablir Continuez de faire fonctionner le remous pendant deux ou trois cycles de la pompe Avancez le contr leur du filtre en position de service et v rifiez la dur e d aspiration de l hydro chargeur Ajustez cette dur e pour qu elle soit gale au tiers d un cycle de la pompe 6 V rifiez si le syst me alimente des applications autre que vos usages domestiques habituels exemples chauffage ou refroidissement g othermique remplissage d une piscine irrigation d une pelouse abreuvoir pour animaux de ferme etc Avez vous ajout une applic
64. s using the following calculation No of people in family x 75 gallons of water per person No of gallons of water for special use No of gallons of water required per day x Iron concentration ppm Daily iron removal requirements ppm 2 Establish backwash frequency using daily iron removal to complete the following calculation 15 000 iron removal capacity ppm Daily iron removal requirements ppm No of backwashes required in 12 day schedule Example You have four in the family 8 ppm of iron and a swimming pool requiring 46 gallons of water per day 4 People in the family x75 Gallons of water per person 300 Gallons of water for family 46 Gallons of water for the pool 346 Gallons of water required per day x8 Iron concentration 2 768 Daily iron removal requirements ppm 15 000 Iron removal capacity ppm 2 768 Daily iron removal requirements ppm 5 4 Backwash frequency days The calculation indicates the need to backwash every 5 4 days The control can only be programmed to backwash at intervals of two three four six and twelve days The control would be programmed to the closest more frequent setting i e every four days Programming Backwash Controls Setting the 24 Hour Timer Press and hold the red button in to disengage the drive gear SERVICE Turn the large dial until the actual time of day is opposite the POSITION 24 HA GEAR time of day pointer Release the red button to re engage the INDICATOR MANUAL
65. ssure tank Make certain pressure is relieved from complete system by opening nearest faucet to drain system Shut off fuel supply to water heater Media Installation When Necessary Remove the valve from the mineral tank e Temporarily plug the open end of the riser tube to ensure that no resin or gravel falls down into the distribution e Fill mineral tank one quarter full of water to protect distribution during gravel installation e Slowly and carefully add the gravel support bed and the softener media leveling each layer as it is placed into the tank e Unplug the riser tube carefully position the valve over it and turn the valve into the threads in the fiberglass tank tightening securely into tank Note Ensure that the internal O ring in the valve fits securely over the riser tube Silicone grease 13691 or other food grade lubricant may be applied to the O ring to ease installation of the riser tube DO NOT use petroleum based lubricants as they will cause swelling of O rings and seals e The softener is now charged with softening resin e It is recommended that the softener tank now be completely filled with water SLOWLY to soak the resin before startup This will allow the media to absorb water as well as help displace any trapped air This will reduce the chance of backwashing resin out during startup 10 11 Cut main supply line as required to fit hydrocharger in plumbing between well pump and pressure ta
66. t the filter inlet is attached to the pipe that supplies water i e runs to the pump and the outlet is the line that runs toward the water heater 5 Before commencing installation it is advisable to study the existing piping system and determine the size number and type of fittings required Typical system schematics shown in these instructions Fig 1 2 or 3 Page 5 will be of assistance NOTE if the plumbing system is used as the ground leg of the electric supply continuity should be maintained by installing ground straps around any non conductive plastic piping used in installation 6 When utilizing a constant pressure or VFD pump system you will require the addition of an air pump and vent tank kit 978003 for 115 volt or 978004 for 230 volt systems A flow switch 79980 will also be required to run the air pump see Figure 4 for installation diagram Section 3 Installation Proper installation sequence of water conditioning equipment is very important Refer to the diagrams following for your particular water supply NOTE The Braukman air vent is not approved for use in the State of Wisconsin An approved air to water tank and or air vent should be used with this application in the State of Wisconsin Figure 1 Iron Free Water Air Release Valve Iron Free Soft Water gt Out 5 To Pump Controller Drain Raw Well Water Softener Iron Filter Pressure Switch Hydrocharger Figure 2 Air Release Va
67. to note the change Section 1 General Information Read this manual carefully and follow the installation steps in order How Your Chemical Free Iron Filter Works The chemical free iron filter consists of two major components which are 1 A hydrocharger located between the well head and the pressure tank adds a small amount of air to the iron laden water whenever the pump runs Refer to Figs 1 2 or 3 on Page 5 for its location Note If your pump system is a constant pressure or variable frequency drive VFD the hydrocharger supplied with this filter will not operate properly The system will require the addition of an air pump and vent tank to introduce the needed air into the water system Refer to page 4 for more information 2 A backwashing type filter containing special media that causes the iron in the hydrocharged water to precipitate throughout the filter bed rather than on the surface as in chemical oxidizing filters This process produces an iron removal capacity of up to 30 000 ppm The media requires no chemical regenerant for oxygen enrichment Your filter automatically adjusts the pH to neutral or higher on acid water without an acid neutralizer The ability to raise pH when it is below neutral 7 0 or less greatly enhances the filter s ability to remove iron efficiently The clean filtered water then flows into your household water line Depending on water use and the concentration of iron in your w
68. ts ext rieurs ou d autres applications forte demande r f rez vous aux figures 2 et 3 pour l quipement additionnel requis R f rez vous aussi la note au bas de l tape 10 POND O L importance du r servoir sous pression Les r servoirs sous pression retrouv s sur les syst mes pour puits priv s deviennent une partie int grale votre syst me de filtration car ils fournissent le brassage et le temps de contact avec l eau hydro charg e Bien que le filtre fonctionne mieux lorsque le r servoir sous pression est du type standard air eau il peut fonctionner de fa on satisfaisante avec un r servoir sous pression air captive vessie natatoire Le r servoir vessie natatoire n cessite un ajustement plus pr cis de l hydro chargeur et un emplacement plus sp cifique du purgeur d air voir figures 8 et 9 Si le temps de base de la pompe est de moins de 30 secondes et qu il y existe des conditions d op ration s v res pH bas haute concentration de fer pr sence de mangan se et un faible concentration de soufre un r servoir sous pression de type air eau standard avec purgeur d air doit tre utilis si un r servoir vessie natatoire est d j en place ne le d sinstallez pas installez le r servoir sous pression air eau entre l hydro chargeur et le r servoir vessie natatoire N B Si votre r servoir sous pression ou tout autre partie de votre syst me d alimentation d eau ne fonctionne
69. y type installation Figure 3 refer to special instructions on Page 7 Loosen set screw and pull out drain line flow control assembly from valve body Unscrew drain line fitting elbow from drain line flow control Apply pipe dope or teflon tape to threads Reassemble to valve body making certain drain line flow control assembly is fully inserted into valve body before tightening set screw Attach 1 2 inch ID drain line to drain elbow CAUTION Set screw requires only finger pressure to hold plastic flow control in place Over tightening set screw may crack fitting Position drain hose over drain and secure firmly To prevent back siphoning of sewer water provide an air gap to code or equivalent Figure 6 Do not raise drain hose more than 10 ft above floor Loosen the two screws on the timer cover to remove it from the timer CAUTION This timer s programs will be out of sync if you turn the knob too far or do not allow the drive motor to stop completely before continuing to the next step If this happens while doing any procedure rotate the knob clockwise until the white dot lines up with the time of day arrow and the unit will return to the service position You can then start again Turn on power to well pump The DUROclean IF is supplied from the factory in the backwash position ready for start up Turn the water supply on to the unit Open the supply line slowly and allow the air to escape from the filter before turning the supply water o

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Usuario Anti Cheats Protector "ACP"  Deutsche Bedienungsanleitung für: Handscanner    EN - User`s manual ()  Subsecretaría - Ministerio de Hacienda y Administraciones Públicas  Padron_IB - ALAMO Sistemas  Dyno-Scan for Palm OS User Guide  User Manual STIM210 Evaluation Kit DOK360.r0  Your new scale includes the following high quality  USER'S GUIDE AND INFORMATION Trip  