Home
Installation and Operation Manual - Ravenna CD - IronStrike
Contents
1. See Shutter Adjustment Detail Figure 18 Figure 17 DETAILA Pulling the adjustment lever toward you will open the shutter pushing it away will close the shutter Figure 18 Shutter Adjustment Detail Battery Backup Battery Installation This appliance is equipped with a battery backup system It requires four 4 AA batteries not provided to power the appliance without the blower during a power outage Install the batteries into the battery holder per instructions in Figure 19 Batteries even if not used will gradually drain over time It is rec ommended to annually check the batteries for sufficient charge and replace when necessary Battery Holder Ensure Positive and Negative ends of the battery are installed as indicated in battery holder O AA Battery Figure 19 0 INSTALLER INSTRUCTIONS ATTACH SAFETY IN OPERATION WARNING LABELS It is required that the set of safety instruction labels that have been furnished with the appliance be affi
2. 23 25 Flame Color and Behavior 25 Paint Curing 25 Quiet 25 Wiring Diagrams esee 26 Maintenance and Servicing 21 28 Maintenance Checklist 21 Glass Maintenance 28 Fuel Conversion 28 Blower 28 Electrical Requirements 28 Replacing A Damaged Barrier 29 Troubleshooting 30 Replacement Parts 31 32 ACCOSSOMNGS 2230225 I 33 34 HIE DII 35 36 Warranty eme ce 37 Product Reference Information 38 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE IMPORTANT SAFETY INFORMATION Important Safety Informa tion 1 WARNING Do not operate appliance with the glass front removed cracked or broken 2 Do not use th
3. 4 Important Safety Information 5 Homeowner Attaching Safety In Operation Warnings 6 Installer Attaching Safety In Operation Warnings 7 Appliance Installation Service and Maintenance Notices 8 Appliance Operation 8 Warranty Information 8 Important Safety And Warning Information 9 Orifice Size Altitude Adjustment 10 Smoke D tact ls riore oaia 10 The Fireplace Insert 10 Fireplace Requirements 10 Codes and 11 Requirements For The Commonwealth of Massachusetts 11 New York City New York MEA 11 Pre Installation ss 12 15 ari fec PE 12 Packaging List 12 RatinQS mm p 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling essere eee 14 Fan Control Module Switch
4. Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e f you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLATEUR Laissez cette notice avec l appareil CONSOMMATEUR Conservez cette notice pour consul tation ult rieure AVERTISSEMENT RISQUED INDENDIE OU D EXPLOSION Le non respect Des avertissements de s curit pour rait d entrainer des blessures graves la mort ou des dommages mat riels Ne pas entreposer ni utilizer d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucan interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez e Sortez imm diatement de b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur e Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL
5. WARNING Never use substitute materials Use of non approved parts can result in poor performance and safety hazards A WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pi ces ne sont pas install es conform ment ces sch mas et ou si des pi ces autres que celles sp cifiquement approuv es avec cet appareil sont utilis es 31 32 REPLACEMENT PARTS RAVENNA CD Cast Pillar Facade Door NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE ACCESSORIES RAVENNA CD Description Ship Weight Black Porcelain REC 8855 RDV BLK PCLPNL RAVENNA CD Black Panels Porcelain Panel Kit required accessory Glass Media Kits required accessory 4549 i 3 LE H 4 Reflective Black Reflective Blue Platinum wer usmrmuk rates wm mmm ws morc mm Goldfinger Copper Gas Conversion Kits OD mis T lt f NUI Wem Den RDICITOC NG Finish Panels front Supports 75253 RDV DBVZC ZC Lower Finish Panel Reg Face Support Requires Trim Pieces below STD SPPT Extende
6. 15 NATIONAL FIREPLACE INSTITUTE We recommend that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists CERTIFIED www nficertified org E AAA 15 21 Venting Installation 15 Vertical Venting 16 Zero Clearance Fireplace Installation 17 Glass 000 i e einn Eten uns 17 18 Firebox Liner Kit Installation required accessory 18 Glass Media Installation required accessory 19 Surround Panels Installation required accessory 19 Facade Installation required accessory 16 Gas Line Installation 20 Gas Pressure 20 LP and Natural Gas Supplies 20 Air Shutter Adjustment 21 Battery Backup Battery Installation 21 Installer Attaching Safety In Operation Warnings 21 Qin eL 22 25 Pre Lighting Checklist 22 Operating Instructions seese sees 22 Intermittent Standing Pilot Mode 22 Operation
7. Juego de etiquetas de repuesto N de cat H8024 IHP IronStrike us com Nota La etiqueta en ingl s es transparente con texto rojo Las etiquetas en franc s y espa ol son negras con texto blanco DIAGRAMAS DE ETIQUETAS DE SEGURIDAD ADVERTENCIA Vidrio y chimenea EXTREMADAMENTE CALIENTES Riesgo de quemaduras graves Siempre mantenga a los ni os alejados de la chimenea V8 BB Figure B Illustrations are for example only Your accessories may be different Les illustrations sont par exemple uniquement Vos accessoires peuvent tre diff rents Las ilustraciones son s lo ejemplos Tu accesorios pueden ser diferentes NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Appliance Installation Service and Maintenance Notices WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier AVERTISSEMENT Une installation un r glage une modification une r paration ou un entretien mal effectu peut causer des dommages mat riels ou des blessures Voir la notice de l utilisateur qui accompgne l appareil Pour de l aide ou des renseignements suppl mentaires consultez un installateur un technicien agr ou le fournisseur de gaz Only trim kit
8. See Detail B Detail B Figure 10 Firebox Liner Kit Installation Instructions 1 Remove the glass door following the instructions provided in this manual 2 Remove the two brackets from the firebox using a 5 32 allen wrench see Figure 11 Retainthe screws for step 4 and discard the brackets as they will not be needed 3 Install the rear liner panel by inserting the tabs on the bottom of each end into the slots on the rear burner retaining tray see Figure 12 4 Install one side liner panel by inserting the tab located on the bottom edge near the back into the same slot as one side of the rear liner panel see Figure 12 Fasten in place using one screw from the brackets removed in step 2 Repeat for the other side liner panel NOTE The side panels overlap on top of the back panel e Figure 13 Panels Installed NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Glass Media Installation Glass Media Kits one required meii wem rass media Pam ws ot md per WARNING e HANDLE MEDIA ONLY WHEN COO
9. Do not cut or remove the grounding prong from this plug Electronic Valve This appliance is equipped with an electronic valve and electronic pilot ignition system which can be switched from Intermittent to standing pilot mode see Page 22 External electrical 120 Volt power is required to operate the blower system of this appliance and recommended to oper ate the burner system This appliance is equipped with a battery backup system in case of a power outage see Battery Backup on Page 21 for more information Fuel THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS This appliance is equipped with an orifice sized for operation with natural gas For conversion to LP propane gas see instructions provided with the appliance Orifices and instructions necessary for LP propane conversion are pro vided in the gas conversion kit see Page 33 for ordering information This appliance comes from the factory equipped to burn natural gas at a specified elevation Only IHP conversion kits can be used to convert from NG to LP or LP to NG Contact your IHP dealer for details RATINGS Max Min Input BTUh 0 2 000 Feet 0 610 M amp e Manifold Pressure IN WC Min Inlet Pressure IN WC Maximum heat output BTUs hour steady state depending on vent configuration Packaging List Insert Body Packaging List i Insert Body Power Cord Fasteners k 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhes
10. Flex Liner 3 X 35 3DFA 35 Adaptor w Flashing Z46DVA GK Termination Cap Z46DVA VC NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 15 16 Vertical Venting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate The combustion air intake pipe can be connected to the termination cap see Figure 7b or it can terminate inside the chimney see Figure 7a If combustion air intake pipe is terminated inside the chimney and not connected to the actual termination cap the bottom opening of the chim ney chimney throat must be sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 Ib per square foot density minimum to seal around the vent pipes Whichever seal off method is used must effectively seal the area to prevent room air passage to the chimney ofthe fireplace The insulation may give off an odor during the first hour of operation NOTE Terminating the air intake liner as shown here may not be al lowed by some local codes Check with the authority having jurisdiction for your area The outside air inlet does not require a full reline if intake liner is terminated in chimney and a positive flue connection is achieved as specified Exhaust 3 75mm UL 1777 A full length liner is required from the exhaust outlet on
11. We recommend that you record the following important information about your appliance Please contact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 31 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order Model Number When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer Innovative Hearth Products 1508 Elm Hill Pike Suite 108 Nashville TN 37210 visit us at IronStrike us com Serial Number Date Installed Your Dealer s Name Fuel Type Checkone _ Natural Gas NATIONAL FIREPLACE INSTITUTE NFI We recommend that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as CERTIFIED NFI Gas Specialists www nficertified org IHP reserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue c
12. 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encendi ndolo y apag ndolo Limpie bien la superficie del panel de control para quitar el polvo y aceite Pegue la etiqueta adyacente al interruptor de control del quemador que controla elartefacto Figura A Seleccione el idioma que m s se habla en la casa 2 Identifique el transmisor de control remoto y limpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura B Seleccione el idioma que m s se habla en la casa 3 Si no puede encontrar las etiquetas s rvase llamar a Innovative Hearth Products o al distribuidor de Innovative Hearth Products m s cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas Juego de etiquetas de repuesto N de cat H8024 IHP IronStrike us com Nota La etiqueta en ingl s es transparente con texto rojo Las etiquetas en franc s y espa ol son negras con texto blanco DIAGRAMAS DE ETIQUETAS DE SEGURIDAD Ay ADVERTENCIA Vidrio y chimenea EXTREMADAMENTE CALIENTES Riesgo de quemaduras graves Siempre mantenga a los ni os alejados de la chimenea 4 2 BB HH WARNING Figure B Illustrations are for example only Your accessories may be different Les illustrations sont par exemple uniquement Vos accessoires peuvent tre diff rents Las ilustraci
13. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e f you cannot reach your gas supplier call the fire department C If any portion of this appliance does not operate as the instructions indicate do not try to repair it call a qualified service technician Do not use tools Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water POUR PLUS DE S CURIT LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risque de d clencher un incendie ou une explosion entrainant des dommages des blessures ou la mort A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement B AVANT DE FAIRE FONCTIONNER reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accum
14. Turn On The Appliance Press the ON OFF Key on the Remote The Remote display will show all active Icons on the screen see Figure 23 and the appliance main burner will turn on A single beep from the Receiver will confirm reception of the command Turn Off The Appliance Press the ON OFF Key on the Remote The Remote LCD display will only show the room temperature and Icon and the appliance burner will turn off A single beep from the Receiver confirms reception of the command Remote Flame Control The system has six 6 flame levels See Figures 24 and 25 for an example With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position see Figure 25 single beep will confirm reception of the command Room Thermostat Remote Operation The Remote Control can operate as a room thermostat The thermostat can be setto a desired temperature to control the comfort level ina room To activate this function press the Thermostat Key The LCD display on the Remote will change to show that the room temperature is ON and the set temperature is now displayed see Figure 23 To adjust the set temperature press the Up
15. 610 M 32 000 21 000 MANIFOLD PRESSURE IN WC MIN INLET PRESSURE IN WC For use only with barrier Part No J7510 Contemporary Face or Part No J7511 Cast Pillar Face Follow installation instructions 27 000 21 000 ORIFICE DMS 0 2 000 FT 0 610 M UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION INSTRUCTIONS FOR ALTITUDES ABOVE 2 000 FT 610M IN CANADA 4500 FT 1370M DE RATE THE APPLIANCE BY FOUR 4 FOR EVERY 1 000 FT 305 M CAUTION HOT WHILE IN OPERATION DO NOT TOUCH SEVERE BURNS MAY RESULT KEEP CHILDREN CLOTHING FURNITURE GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY KEEP BURNER AND CONTROL COMPARTMENT CLEAN SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING APPLIANCE FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED CRACKED OR BROKEN REPLACEMENT OF THE PANEL S SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THE OWNER S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A Q
16. CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A harrier designed to reduce the risk of burns from the hot viewing glass is pro vided with this appliance and shall be installed for the protection of children and other at risk individuals Included with required facade Voir ci joint tract pour une bonne repr sentation de la couleur DANGER VITRE CHAUDE 5 RISQUE DE BR LURES NE TOUCHEZ PAS UNE VITRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personnes risques incluse avec le facade Requis Vea el volante adjunto para la representaci n de color adecuado PELIGRO EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NINOS DEBEN NUNCA TOCAR EL VIDRIO Una barrera dise ada para reducir el riesgo de quemaduras desde la mirilla vidrio caliente es proveida con este aparato y deber instalarse para la protecci n de los ni os y otros individuos en riesgo Incluida con la fachada requerida NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Safety and Your Fireplace Insert All parts of your IHP fireplace insert get EXTREMELY HOT To prevent severe burns and in
17. Distance from base of appliance to Hearth Extension i 54mm 102mm E Minimum Horizontal Distance 10 from Front of Appliance Figure 5 Clearances gt 3 76 gt 3 76mm lt RDV CD Facing and Mantel Side View 33 1 2 851mm Figure 4 MINIMUM CLEARANCES Front View MANTEL FACING 4 A i 0 Hearth Protection 330mm 254mm _ NOTE Hearth protection to be min 3 8 10mm thick non combustible or eguivalent with a k factor of 84 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE FAN CONTROL MODULE SWITCH Before installation verify the power switch on the Fan Control Module is in the ON position as shown in Figure 6 Fan Control Module FCM Figure 6 ON Position INSTALLATION Venting Installation Your IHP appliance must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code This appliance requires a 3 diameter listed flex liner The vent should terminate with a listed direct venttermination cap The chimney should be sealed around the cap to prevent air and rain from entering the chimney Adhere to the vent manufacturer s instructions for installation and vent termination These appliances are approved for use with the following vent kits Simpson Dura Vent
18. appli ance to center collar of termination cap Existing Fireplace Flue chimney Positive Flue Con nection sealing fireplace throat using a noncombus tible seal off plate Air Inlet Liner for combustion air When or insulation terminating the air inlet liner at this point a positive flue connection is required to ensure combustion air is drawn down the chimney only Masonry and Factory Built Fireplaces Figure 7a Terminating Air Inlet in Chimney NOTE The minimum vertical rise exhaust vent is 10 feet 3 1 M and the maximum vertical rise is 35 feet 10 7 M These dimensions are measured from the starting collars of the unit to the end of the vent pipe The fireplace and fireplace chimney must be clean and in good working order and constructed of non combustible materials Inspect chimney cleanouts for proper fit and seal The existing fireplace chimneys may take various contours which the flexible liners will accommodate However keep the flexible liner as STRAIGHT as possible avoid unnecessary bending Vertical Cap Termination Connector SES Liner Requirements Use 3 76 mm diameter listed gas vent liner UL1777 ONLY for the EXHAUST Use 3 76 mm diameter listed liner UL 181 or UL1777 for the AIR INTAKE Vertical Height Min 10 ft 3 1 M Vertical height Max 35 ft 10 7 M Note Measured from flue collar on unit to the end of the vent pipe or liner T
19. encouru Les surfaces de votre foyer deviennent EXTREMEMENT CHAUDES La vitre situ e l avant du foyer atteint des temp ratures EXTR MEMENT ELEVEES et peut causer de graves blessures en cas de contact Tenez les enfants l cart du foyer lorsqu il fonctionne Surveillez attentivement les enfants dans les pi ces o un foyer est utilis afin d viter qu ils ne soient en contact avec la vitre Tenez tous les v tements les meubles l essence et tout autre liquide inflammable l cart du foyer M me apr s fermeture du gaz les surfaces du foyer restent extr mement chaudes Veillez coller les tiquettes de mise en garde relatives la s curit d utilisation l endroit o vous utilisez le foyer pour rappeler tous les utilisateurs les dangers li s aux temp ratures lev es voir pages 6 7 Lisez la section Informations importantes relatives la s curit page 5 FRENCH chimenea iTodas las partes de la chimenea IHP se ponen MUY CALIENTES Para evitar quemaduras y lesiones graves no quite el protector de malla o guardia de seguridad que evita el contacto directo con el vidrio Siga las instrucciones de seguridad a continuaci n y aseg rese de que todos en su hogar sepan acerca de este peligro de quemadura iLas superficies de la chimenea se ponen MUY CALIENTES El vidrio delante de la chimenea alcanza tempe
20. for available sizes 1 Co N A o co Remove the speed nuts A in Figure 15 from the parts bag and install with the flat surface forward on the six holes in the surround brack ets three on each side of the insert B in Figure 15 flat bladed screwdriver may help in installing the nuts Install all surround panels and trim with the appliance positioned in the fireplace but a few inches in front of its final location If an Arch face is to be installed on the appliance the sight obstructor that comes with the face must be installed prior to installing the sur round panels See the instructions included with the face for proper sight obstructor installation Install the side surround panels by lining up the holes in the tabs on the side surround panels in front of the holes on the surround brackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the surround panels to eliminate space between side and top surround panels Assemble the surround trim by inserting the elbowed retainer in the rectangular slot in the ends of the longest piece of trim and secure by tightening the screw in the retainer Slide the mitred ends of the two side trim pieces onto the elbowed retainer and secure by tightening the retainer screw The fastened
21. gas load for the residence does not exceed the amount supplied Propane tanks are at pressures that will cause damage to valve com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Fuel Inlet Pressure Manifold Pressure Type Desired On Lo Fire Stepper Motor Pressure Regulator Green Wire From DFC Wire Harness Inlet Supply Pressure Tap Outlet Manifold Pressure Tap Main Gas Inlet Yellow Ground Wire From DFC Wire Harness Figure 16 SIT Proflame Electronic Valve Stepper LP and Natural Gas Supplies This appliance is equipped from the factory for use with natural gas only as specified on the Safety Listing label attached to the appliance This appliance can only be operated using propane gas LP if a certified fuel conversion kit provided by IHP is installed by a qualified service technician Also check the orifice size on the label which is located in the control compartment It must be the correct size for the fuel and altitude Do n
22. les traces de graisse ou d huile Collez l tiquette sur le boitier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 3 Sivous ne parvenez pas localiser les tiquettes s il vous plait contactez IHP ou votre revendeur le plus proche pour recevoir IHP tiquettes d instructions de s curit suppl mentaires gratuitement Etiquettes de remplacement n cat H8024 IHP IronStrike us com Remarque Le texte anglais est rouge sur un support transparent Le texte fran ais et espagnol est blanc sur un support noir DIAGRAMMES DES TIQUETTES DE S CURIT AVERTISSEMENT Vitre et foyer EXTREMEMENT CHAUDS Risque de br lures graves Toujours tenir les enfants l cart du foyer T COMFORT CONTROL COLOCACI N DE ADVERTENCIAS DE SEGURIDAD EN OPERACI N Su artefacto incluye etiquetas de instrucciones de seguridad que deben colocarse en los puntos de operaci n y control del artefacto Se debe colocar una etiqueta de instrucciones de seguridad adyacente al interruptordecontrol del quemadordondeseenciendey se apaga el artefacto ver la Figura A y en el transmisor decontrol remoto Figura B Las advertencias ya deben haberse colocado cuando se complet la instalaci n inicial del artefacto Si no est n colocadas en estos lugares encuentre las etiquetas adhesivas multiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera
23. of the unit Conduct a gas leakage test of the appliance piping and control system downstream of the shutoff valve in the supply line to the appliance Gas Pressure Requirements A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES IS IMPROPER GAS PRESSURE The most important item to check during the initial installation and the first thing to check when operating problems occur is gas pressure This appliance will not function properly unless the required gas pressure is supplied See the table on this page for gas pressure requirements Two pressure taps are provided on the appliance s valve to check gas pressures see Figure 16 for locations To check inlet pressure with the appliance burning insert a small flat blade screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from a manometer and check the pressure Close the tap gently but securely after completing the check To check manifold pressure with the appliance burning at the high burn setting insert a small flat blade screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total
24. s supplied by the manufacturer shall be used in the installation of this appliance Seules les trousses de garniture fournies par le fabricant doivent tre utilis es pour l installation de cet appareil These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance Any change to this appliance and or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualified professional as it may not be operating correctly Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Si l cran est endommag il doit tre remplac par celui fournit par le fabricant de cet appareil Reinstall any barrier removed before operating the appliance The barrier is design
25. use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently NEVER use brass polish to clean plated surfaces this will remove the plating CAUTION Hot while in operation Do not touch Severe Burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away ATTENTION L appareil est chaud lorsqu il fonctionne Ne pastoucher l appareil Risque de br lures graves Surveiller les enfants Garder les v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l appareil Clearances are in accordance with local installation codes and the requirements of the gas supplier Les d gagements sont conformes aux codes d installation locaux et aux exigences du foumisseur de gaz This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit tre utilis uniquement avec les types de gaz indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gaz sauf si un kit de conversion certifi est install WARNING Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carb
26. vented outside the structure Combustion air is drawn from outside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open IMPORTANT When installing these appliances into a factory built fireplace or heat form the air flow within and around the fireplace shall not be altered by the installation of the insert i e DO NOT BLOCK louvers or cooling air inlet or outlet ports circulating air chambers in a steel fireplace liner or metal heat circulator CAUTION e Trim panels or surrounds must not seal ventila tion openings in the existing fireplace that the appliance is installed in The fireplace in which this gas insert is to be installed must be thoroughly cleaned if it has been used to burn wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be drawn into the heat circulation blower and blown into the living area If any portion of the chimney system shows signs of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert without modification other than removing bolted or screwed together pieces such as baffles smoke shelf deflectors ash lips glass door scree
27. 21 Check for debris obstructing air flow in valve compartment under insert or in front of lower venting See Quiet Operation on Page 25 The noise may be reduced by slightly turning down the flame Turning the flame down will reduce the heat output of the appliance If noise is excessive or is whistling have your gas supplier check the regulator and orifices and replace if necessary Have your gas supplier check for correct inlet gas supply pressure 7 W C po 1 74 kPa natural gas 11 W C po C E 2 74 kPa LP gas NOTE NEVER BLOCK OR OBSTRUCT AIR INTAKE OR OUTLET VENTS See Firebox Liner Kit and Glass Media Installation on Pages 18 and 19 Check the gas supply and gas shutoff valves Check control compartment for any obvious loose wiring call a service technician if required Call for a service technician Call for a service technician Check the gas supply and gas shutoff valves Check replace back up batteries see Battery Backup on Page 21 Check building circuit breakers to ensure power is on to the appliance Check Fan Control Module power switch to ensure power is on see Figure 6 on Page 15 Check the gas supply and gas shutoff valves Check control compartment for any obvious loose wiring calla service technician if required Check control compartment for any obvious loose wiring calla service technician if required Purge gas line of air call a service technician if required R
28. ACK Trim DBV E n 30 RDV DBV FP3348 C 33 x 48 BLACK Trim 762mm Cast Surround Assembly For Pillared Face Dimensions 22 7 8 581mm Contemporary Facade Kits With Barrier 44 1118mm 2322 RDV CONTF BLK Contemporary Facade Black 2323 RDV CONTF MNK Contemporary Facade Mink NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL RAVENNA CD SERIAL pk t us MANUFACTURED BY INNOVATIVE HEARTH PRODUCTS Report No 14 192 1502 14TH ST NW STR I KE AUBURN WA USA 98001 EAT FOR LIFE FACTORY EQUIPPED FOR NATURAL GAS IF CONTROL PANEL CONTRADICTS THIS LABEL UNIT FUEL TYPE HAS BEEN CONVERTED VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21 88 2014 CSA 2 33 2014 AND CANICGA 2 17 M91 R2009 THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES IF ANY IF NOT FOLLOW THE CURRENT ANSI Z223 1 NFPA 54 LATEST EDITION USA OR CAN CGA B149 1 LATEST EDITION CANADA THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION INSTRUCTION FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY MASONRY OR FACTORY BUILT THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN AFTERMARKET PERMANENTLY LOCATED MANUFACTURED HOME USA ONLY OR MOBILE HO
29. EPLACEMENT PARTS RAVENNA CD er o ar i me Coast Fes en eda ing See s mem mounting wem T Freno Door Assemb win cias mms mvcommerksemy s omes Rov core Como Pana u omes heat shies Fan Canoe s ome over Snan Sun mart _ s wmm rower cor ose a omms ation onto Boat gt wan Remote Receiver GGT Replacement ars Remote GTF epicoment omma owon swin as omma ron comoro wem mmm H8489 Ignition Control Board amp Remote Receiver Wirng Harness 18 H8496 RDV TCC CD Blower Wiring Harness H8859 Cassette Assembly NG 32 000 BTU if LP also requires H8858 Conversion Kit H8490 3 8 NPT Pipe Nipple 8 H5924 Orifice Main Burner 36 NG 32 000 BTU H5964 Orifice Main Burner 53 LP 27 000 BTU H8491 Pilot Assembly Convertible NG or LP H8509 Gas Control Valve TCC CD Auto Hi Lo Regulator NG if LP also requires H8858 LP Regulator H8458 Gas Conversion Kit TCC CD Auto Hi Lo Regulator LP to NG peu H8858 Gas Conversion Kit CD Auto Hi Lo Regulator NG to LP wm wietonmet x omes ha and toop Dot ans s Power Miamor Box sem MT E H8159 Touch Up Paint Metallic Black 12 oz aerosol Contact an IHP dealer to obtain any of these parts Please contact IHP for the phone number of your nearest IHP dealer
30. ET PEUT TRE INSTALL DANS UNE MAISON PR USIN E OU DANS UNE MAISON MOBILE FIXE L OU LES CODES R GIONAUX LE PERMETTENT VOIR LE MANUEL D ENTRETIEN POUR PLUS DE D TAILS CET APPAREIL NE PEUT PAS TRE CONVERTI POUR L USAGE AVEC D AUTRES TYPES DE GAZ MOINS D UTILISER UNE TROUSSE DE CONVERSION HOMOLOGU E DANGER RISQUE DE CHOC LECTRIQUE D BRANCHEZ L APPAREIL AVANT D EN FAIRE L ENTRETIEN SI L APPAREIL REQUIERT UN BRANCHEMENT LETRIQUE LES RACCORDEMENTS ET LA MISE LA TERRE DOIVENT TRE CONFORMES AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 70 OU CSA C22 1 DIMENSIONS MINIMUMS DE FOYERREQUISES Ravenna CD DEGAGEMENTS MINIMUMS 31 50 800mm MANTEAU cT cm Toe Irgeur arri re 1 mm A B gt Profondeur 16 00 406mm PERLE c D GAGEMENTS AUX COMBUSTIBLES A Du bas de l appareil au dessous de D la finition sup rieure 31 5 800mm I B Du centre de la vitre 25 5 648mm mi C 10 5 267mm manteau de foyer partir Eh de la base 39 991mm PROTECTION DU FOYER D Distance verticale de la base de 2 4 Note Extension d tre fabriqu avec de l appareil l extension d tre OMM 51mm 102mm 3 8 10mm minimum de mat riaux E Extension d tre min l avant 13 10 0 non combustible ou quivalent de l appareil 330mm 54mm poss
31. IHP dealer Do not use substitute parts or materials The glass is neo ceramic and alternative types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Fuel Conversion Converting this appliance between natural gas and propane LP can be accomplished by installing a gas conversion kit Only a qualified service technician should perform the conversion Gas Conversion Kits Please see instructions provided with conversion kit Removing And Cleaning Media CAUTION Risk of personal injury Allow media to completely cool before handling To remove glass media from appliance for cleaning or replace ment Use a clean dry empty shop vac 1 Place media in colander or sieve and carefully rinse under hot water 2 Allow media to air dry before reinstalling Blower Removal Unplug the power supply cord from the electrical outlet prior to removing the blower The blower can be accessed through the back wall of the firebox Remove the insert face glass door firebox panels glass media burner assembly and front and rear media trays All of these items are fragile so handle them with care Next remove the five allen head screws around the outside of the panel fastened to the back wall of the firebox Rotate the top of this panel toward the front remove the two wires connected to the blower and then lift the panel with the blower att
32. ING INSTRUCTIONS STOP Read the safety information above on this label Read the operation section of the Installation and Operation manual Turn the burner ON OFF switch in the control compartment to OFF Turn OFF all electric power to the appliance This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this page If you do not smell gas go to the next step Turn on all electric power to the appliance Turn the burner ON OFF switch in the control compartment to ON After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner Momm If the appliance will not operate follow the instructions DO To Turn Off Gas To Appliance and call your service 100 technician or gas supplier Valve lectronique SIT Proflame Electronic Pilot Assembly Module de veilleuse lectronique Control Switches TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch in the control compartment to 2 Turn off all electric power to the appliance if service is to he OFF performed P N 580418 01 Rev A 10 2014 3 Closethe main line gas shut off valve DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NE
33. INSTALLATION AND OPERATION 12 4 00 IRONSTRIKE HEAT F R LIFE Direct Vent a EAT P N 900124 00 REV A 01 2015 0 French manual is available upon request Order P N 9001 84 00 MODELS RDV CD Ce manuel d installation est disponible en francais s implement en faire la demande Num ro de la pi ce 900184 00 This appliance may he installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil peut install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Ce appareil doit tre utilis uniquement avec le type de gaz indiqu sure la plaque signal tique Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utils e WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately
34. L Turn OFF all electricity to the appliance before installing media Media gets very HOT during fireplace use and will remain hot up to one hour after the gas supply is turned off e Any attempt to use media not specified for your fireplace configuration will result in incomplete combustion sooting and poor flame quality and will void the warranty 1 Fill the provided measuring box level with the top approximately 3 cups 2 Distribute the measured amount of media in an even layer in the recessed area on top of the burner shaded area in Figure 14 IMPORTANT Do NOT mound up media f using multiple colors of media NEVER use more than one level measuring box approximately 3 cups total at one time e lf media is not installed according to the media installation instruc tions flame impingement and improper combustion could occur and result in soot and or excessive production of carbon monoxide CO a colorless odorless toxic gas OTe Figure 14 Media Installed Surround Installation The fireplace insert surround panels are made of heavy gage steel for durability and if desired for the ease of making an inside fit in the fire place See Packaging List
35. ME WHERE NOT PROHIBITED BY LOCAL CODES SEE OWNER S MANUAL FOR DETAILS THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED DANGER RISK OF ELECTRICAL SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IF ELECTRICALLY CONNECTED CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES IF ANY IF NOT FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI NFPA 70 LATEST EDITION USA OR CSA C22 1 LATEST EDITION CANADA MINIMUM FIREPLACE SIZES REQUIRED Ravenna CD 3150 00mm MINIMUM CLEARANCES 19 50 495mm MANTEL j 8 00 457mm FACING 2 46 00 406mm MINIMUM CLEARANCES TO COMBUSTIBLES Top Facing to Bottom of Appliance 31 5 800mm B Side Facing or Side Wall to Center of Glass 25 5 648mm C 10 5 267mm Mantel to Bottom of Applian 39 991mm HEARTH PROTECTION n D D Vertical Distance from base of to Hearth Extensioi Minimum Horizontal Distance 43 107 0 from Front of Appliance mu 330mm 254mm See owner s manual for additional mantel clearances and options gt gt re Omm 51mm 102mm Note Hearth protection to be min 3 8 10mm thick non combustible or equivalent with a factor of 84 RATINGS Ravenna CD RDV CD NATURAL GAS LP GAS MAX MIN INPUT BTUH 0 2 000 FT 0
36. SAFETY AND WARNING INFORMATION INSTALLER THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER FOR YOUR SAFETY do not install or operate this appliance without first reading and understanding this manual Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazardous IHP its employees or any of its representatives assume no responsibility for any damages caused by an inoperable inad equate orunsafe conditionas a resultof any improper operation service or installation procedures whether direct or indirect DO NOT ATTEMPT TO SERVICE THE APPLIANCE YOURSELF Do not make any make shift compromises during installation Any modification or alteration may result in damage to the ap pliance or dwelling and will void the warranty certification and listings of this unit Failure to use manufacturer provided parts variations in tech niques and construction materials or practices other than those described in this manual may create a fire hazard and void the limited warranty This gas appliance must be equipped for the proper fuel type and altitude at which it will be operated Any operation outside the parameters outlined in this manual may result in a hazard ous condition and will void the warranty Please carefully read the sections pertaining to these subjects and or be sure your appliance is properly equipped lt Never
37. T AUTRES VAPEURS ET LIQUIDES INFLANMABLES MAINTENEZ LE BR LEUR ET LE BOITIER DES COMMANDES PROPRE EN TOUT TEMPS VOIR LES MANUELS D INSTALLATION ET D ENTRETIEN QUI ACCOMPAGNENT L APPAREIL SEUL LE PANNEAU VITR FOURNI PAR LE MANUFACTURIER PEUT TRE UTILIS AVEC CET APPAREIL EN AUCUN CAS L APPAREIL NE PEUT TRE UTILIS SANS LA VITRE OU AVEC LA VITRE BRIS E LE REMPLACEMENT DE LA VITRE DOIT TRE EFFECTU PAR UN TECHNICIEN DE SERVICE QUALIFI AVERTISSEMENT UNE INSTALLATION INAD QUATE DE M ME QU UN AJUSTEMENT UNE MODIFICATION UNE R PARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES A LA PROPRIETE REFEREZ VOUS AU MANUEL D ENTRETIEN LIVRE AVEC CET APPAREIL POUR DE L ASSISTANCE CONSULTEZ UN INSTALLATEUR QUALIFIE UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ La date de fabrication est indiqu e dans la section anglophone de cette tiquette No pi ce 900376 00 Rev 0 12 2014 N ENLEVEZ PAS OU NE COUVREZ PAS CETTE TIQUETTE NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 35 LIGHTING LABEL RAVENNA CD FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas
38. UALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER DATE OF MANUFACTURE DATE DE FABRICATION 2017 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT OOOOOOoOoOoOu DO NOT REMOVE OR COVER THIS LABEL 2014 2015 2016 NOV DEC OO Part No 900376 00 Rev 0 12 2014 MODELE SERIAL Le num ro de s rie est indiqu dans la O NO section anglophone de cette tiquette PFS Us FABRIQU PAR INNOVATIVE HEARTH PRODUCTS J Rapport n 14 192 1502 14TH ST NW IR NSTRIKE AUBURN WA USA 98001 HEAT F R LIFE CET APPAREIL EST MUNI D QUIPEMENT POUR L USAGE DU GAZ NATUREL SI L TIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE TIQUETTE C EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A T CONVERTI FOYER AU GAZ VACUATION NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE CONFORME AU STANDARD ANSI Z21 88 2014 CSA 2 33 2014 ET CANICGA 2 17 M91 R2009 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI 54 DERNIERE DITION ETATS UNIS OU CANICGA B149 1 DERNI RE DITION CANADA CET APPAREIL DOIT TRE INSTALL SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS COMBUSTIBLE SOLIDE SEULEMENT DE MACONNERIE OU PR FABRIQU EN USINE CE FOYER RADIANT AU GAZ VACUATION N EST PAS CON U POUR TRE UTILIS AVEC DES FILTRES AIR CET APPAREIL DOIT TRE UTILIS AVEC LE TYPE DE GAZ INDIQU SUR LA PLAQUE SIGNAL TIQUE
39. UCTIONS ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS Yourappliance has beenfurnished with safety instruc tion labels that are to be affixed to the operation and control points of the appliance A safety instruction label should be affixed next to the burner control switch where the appliance is turned on and off See Figure A andthe remote control handheld transmitter See Figure B The warnings should already have been put in place when the appliance initial set up was completed If they are not affixed at these spots locate the multi lingual adhesive labels provided with these instructions and proceed as follows 1 Locate the control switch on the control panel of your appliance verify the switch operates the appliance by turning it on and off Clean the surface on the control panel thoroughly to remove any dust and oils Affixthe label next to the burner control switch that controls the appliance Figure A Choose the language primarily spoken in the home 2 Locate the remote control transmitter and clean it thoroughly to remove any dust and oils Affix the label to the surface of handheld transmitter Figure B Choosethe language primarily spoken in the home 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealerto receive additional safety instruction labels free of charge Cat No H8024 Replacement Label Kit IHP IronStrike us com Note Englis
40. VER ALLOW CHILDREN TO TOUCH GLASS A harrier designed to reduce the risk of burns from the hot viewing glass is pro vided with this appliance and shall be installed for the protection of children and other at risk individuals Included with required facade NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 2 TASSE 2256090 27 ZZ 27 lt SSS LT ZSSS SX Sey 2 59 25 As n 5 ss 20 oos a a SY se 20 59 rans 20 S y s yoo BS a 5 Ms 26 59 e d n 5 Sy 0 BS a 5 SS 50 SOS Oe d n 5 Sey 20 oos BS As n 77 A SL 27 gt AIRS N D SST NS LZ 7 SS NS WS SS lt Ss Innovative Hearth Products IronStrike Brand Gas Fireplaces Stoves and Inserts 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products IHP 20 Year Limited Warranty warrants your lronStrike brand gas fireplace or insert Product to be free from defects in materials and workmanship at the time of manufacture The Product body and firebox carry the 20 Year Limited Warranty Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only After installation if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation IHP will at its option repair or replace the
41. ached out of the firebox Remove the blower assembly by removing the two screws hold ing it to the panel bracket To reinstall the blower repeat these steps in the reverse order Electrical Requirements This appliance is equipped with an electronic valve and electronic pilot ignition system which can be switched from Intermittent to standing pilot mode see Page 22 External electrical 120 Volt power is required to operate the blower system of this appliance and recommended to oper ate the burner system This appliance is equipped with a battery backup system in case of a power outage see Battery Backup on Page 21 for more information This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code Part 1 CSA C22 1 latest edition See Operating Options for burner ON OFF switch information NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Replacing Damaged Barrier Ifthe barrier becomes damaged the barriershall be replaced with the manufacturer s barrier for this appliance For use with barrier Part No J7510 Contemporary Facade or J7511 Cast Pillar Facade Follow installation instruc tions Removing The Damaged Barrier Contemporary Facade see Figure 29 1 2 Make sure the unit is off and cold Remove the contemporary facade from the unit by grippin
42. al operational sounds may be heard The flow of gas through the gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 3096 When the blower turns on the sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed of the blower assembly Also a slight clicking sound may be heard as the gas valve or blower switch turn on and off NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 25 POWER 120 V AC ADAPTOR BOX ROOM AIR BLOWER FAN CONTROL MODULE BURNER CONTROL NOTE SWITCH CONDITIONS BOARD GIVEN AT ROOM TEMPERATURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT gt MALE DISCONNECT O STUD CONNECTION AUTO RESET TEMPERATURE SWITCH N O PILOT ON AUTO REMOTE RECEIVER SWITCH Figure 27 Electronic Control Schematic Models RDV CD CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation ATTENTION Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entrainer un fonctionnement inad quat et dangereux NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE MAINTENANCE AND SERVICING WARNING Turn off gas and electrical power to the fireplace and allow i
43. biliario y cortinas 4 Se debe alertar a los ni os y adultos sobre los peligros de las altas temperaturas en la superficie y que se mantengan alejados para evitar quemaduras o ignici n de la ropa 5 No debe colocarse ropa otros materiales inflamables sobre y cerca del artefacto 6 Se debe supervisar de cerca a los ni os cuando est n en el mismo cuarto que el artefacto Los nifios pequefios los j venes y otras personas pueden ser susceptibles a quemaduras por contacto accidental Se recomienda instalar una barrera f sica si hay personas en riesgo en la casa Para restringir el acceso a una chimenea o estufa instale una puerta de seguridad ajustable para mantener a los nifios peque os j venes y otras personas en riesgo fuera del cuarto y lejos de las superficies calientes 1 Cualquier malla o resguardo de seguridad quitado para dar servicio a un artefacto debe reinstalarse antes de operar el artefacto 8 Una persona de servicio competente debe realizar la instalaci n y reparaci n Una persona de servicio profesional debe inspeccionar el artefacto antes de usar al menos una vez por a o Se puede requerir limpieza m s frecuente debido a la pelusa excesiva del alfombrado del material de cobijas etc Es imprescindible mantener limpios los compartimientos de control los quemadores y los pasajes de circulaci n del aire del artefacto Ver las instrucciones de mantenimiento en la p ginas 27 29 HOMEOWNER S INSTR
44. covered components If repair or replacement is not commercially practical IHP will at its option refund the purchase price or wholesale price of the IHP product whichever is applicable IHP will also pay IHP prevailing labor rates as determined in its sole discretion incurred in repairing or replacing such components for up to five years THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 SR Year Limited Warranty as described herein COVERAGE COMMENCEMENT DATE Warranty coverage begins on the date of installation In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from IHP regardless of the installation or occupancy date EXCLUSIONS AND LIMITATIONS This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices QL This warranty is non transferable and extends to the original owner only The Product must be purchased through a listed supplier of IHP and proof of purchase must be 2 provided The Product body and firebox carry the 20 Year Limit
45. d Side Trim Black 75251 75062 75063 GFHKET G Extended Side Trim Gold GFHKETN Extended Side Trim Nickel NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 33 34 GFT2941 B Trim Black 29 x 41 Note 3 boxes to complete face GFT2949 8 Trim Black 29 x48 a ma T 37 5 8 W x 23 3 4 rim Black 33 x 41 TET m em F2324 PILCST GLASS BARRIER Cast Door Box 1 of 3 T GOG eT YT 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75038 GFT2948 G Trim Gold 29 x 48 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 Or Surround Trim Kits Pillar Cast Face Kits Ex 75040 GFT3341 G Trim Gold 33 x 41 75091 PILCST GRL FIL3 Grill filigree Ornate Box 3 of 3 75042 GFT3348 G Trim Gold 33 48 75037 GFT2941 N Trim Nickel 29 x 41 Cast Black Surround Panels see drawing below 15039 GFT2948 N Trim Nickel 29 x 48 75156 RDV DBV PCFP3044 TOP Top Box 1 of 2 75041 GFT3341 N Trim Nickel 33 x 41 75157 RDV DBV PCFP3044 SIDES Sides Box 2 of 2 75043 GFT3348 N Trim Nickel 33 x 48 Le 45 1 2 1156mm Surround Panel Kits required accessory 12 1156mm H8520 RDV DBV FP2941 C1 29 x 41 BLACK Trim One piece E H8521 RDV DBV FP2941 C 29 x 41 BLACK Trim H8522 RDV DBV FP2948 C 29 x 48 BLACK Trim 4 1 1 8 181mm E 44 1 2 1130mm a RDV DBV FP3341 C 33 x 41 BL
46. dant un facteur de 0 84 Voir le manuel d entretien pour les informatinos suppl mentaires reli es aux distances respecter pour le manteau de foyer SP CIFICATIONS R CD RDV CD E avenne 2 Utiliser uniquement avec GAZ NATUREL GAZ PROPANE l cran no 7510 ensembles ENTR E MAX MIN BTU HR 0 4500 pi 0 1370 M 32 000 21 000 27 000 21 000 face contemporaine ou PRESSION LA SORTIE IN WC C E 3 5 10 0 no J7511 face de colonne coul e Suivre les PRESSION MINIMUM D ENTR E DU GAZ IN WCIC E x E hs d instructions d installation ORIFICE DMS 0 4500 pi 0 1370 M L APPAREIL PR USIN EST MUNI D QUIPEMENT POUR 0 2000 PIEDS 0 610 M AU CANADA 0 4500 PIEDS 0 1370M SP CIFICATIONS LECTRIQUE 120 VCA 60 HZ MOINS DE 2 AMP RES CHEMIN E POUR LA SORTIE D VACUATION DES GAZ UTILISEZ UNE GAINE DE TUBAGE CERTIFI SELON UL1777 OU ULC S635 APPAREIL TRE RELI UN SYST ME D VACUATION TEL QUE SP CIFI DANS LE MANUEL D INSTALLATION DU ALTITUDE AU DEL DE 2000 Pl 610 ad CANADA 0 4500 PI 0 1370M LA CAPACIT NERG TIQUE DE L APPAREIL DIMINUE DE QUATRE 4 POUR CHAQUE 1000 PI 305 DANGER CET APPAREIL D GAGE DES TEMPERATURES LEV ES ET DEVRAIT TRE INSTALL L CART DES ENDROITS TR S PASSANTS ET LOIN DES MEUBLES ET RIDEAUX SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PI CE GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MAT RIAUX COMBUSTIBLES D ESSENCE E
47. e Glass is susceptible to damage Do not scratch or handle roughly while reinstalling the glass door frame e The glass door s of this appliance must only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately e Do not attempt to touch the front enclosure glass with your hands while the appliance is in use e Do not use abrasive cleaners Never clean the glass when it is hot e DO NOT abuse glass door by striking or slamming shut A WARNING Do not operate the appliance with the glass front removed cracked or broken A AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en place est craqu ou bris Only doors certified with the appliance shall be used Seules des portes certifi es pour cet appareil doivent tre utilis es Do not remove glass door while the appliance is hot Glass Door Removal To remove the glass door 1 Pull latches on the bottom right and left of the door out of the slots and place below the tab on the front door 2 The door can now be pulled from the bottom away from the firebox and lifted up and off the firebox 3 To reinstall the door complete the steps in reverse order Figure 8 Detail A NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 17 18 Figure 9
48. e of handheld transmitter Figure B Choose the language primarily spoken in the home If unknown affixthe English language label 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealer to receive additional safety instruction labels free of charge Cat No H8024 Replacement Label Kit IHP IronStrike us com Note English is red text on clear label French and Spanish are white text on black label SAFETY LABEL DIAGRAMS WARNING EXTREMELY HOT glass and fireplace Risk of Severe Burns ALWAYS KEEP CHILDREN AWAY FROM FIREPLACE Figure A APPOSJTION DES MISES EN GARDE RELATIVES ALA SECURITE D UTILISATION ll est imp ratif que le jeu d tiquettes de s curit qui ont t fournies avec le foyer soient coll es c t des dispositifs de contr le du imp ratif Une tiquette de s curit devrait tre coll e sur la plaque du r cepteur contr lant l allumage de l appareil voir Figure A et sur le bo tier de la t l commande Figure B Les mises en garde auraient d tre coll es au momentdel installation initiale de l appareil Si ce n est pas le cas prenez les tiquettes adh sives multilingues fournies avec ces instructions et proc dez comme suit 1 Rep rezle contr leur sur le panneau de contr le de votre appareil v rifiez que l interrupteur contr le le fonctionnement de l appareil en le faisant basculer de Marche Arr t et vice versa Nettoyez soi
49. ed Warranty from the date of installation Vent components trim components and paint are excluded from this OS 20 Year Limited Warranty The following do not carry the 20 Year Limited Warranty but are warranted as follows Burner Repair or replacement for one year from the date of installation Gas components Repair or replacement for one year from the date of installation Gaskets Repair or replacement for one year from the date of installation Gold amp nickel plating Replacement for two years from date of installation Excludes tarnishing Logs Replacement for year from the date of installation against thermal breakage only Optional blowers amp remote controls Repair or replacement for one year from the date of installation SQ Optional glass doors Repair or replacement for 90 days from the date of installation Tempered glass Replacement for one year from the date of installation Labor coverage Prevailing IHP labor rates apply for the warranty period of the component Parts not otherwise listed carry a 90 day warranty from the date of installation Whenever practicable IHP will provide replacement parts if available for a period of 10 years from the last date of manufacture of the Product IHP will not be responsible for a damages caused by normal wear and tear accident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repai
50. ed to reduce the risk of burns from hot glass Do not operate the appliance without the barrier installed Appliance Operation Notices These fireplace inserts are vented gas appliances Do not burn wood or other material in these appliances These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper op eration Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a dwelling Warranty Information Your gas appliance is covered by a limited 20 year warranty You will find a copy of the warranty accompanying this manual Please read the warranty to be familiar with its coverage Retain this manual File it with your other documents for future reference Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance voiding its warranty Do not attempt to alter or modify the construction of the appliance or its components Any modification or alteration may void the warranty certification and listings of this unit NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE IMPORTANT
51. efacto se coloque en los puntos de operaci n y control de la misma Se debe colocar una etiqueta de instrucciones de seguridad adyacente al interruptor de control del quemador donde se enciende y se apaga el artefacto ver la Figura A y en el transmisor de control remoto Figura B Las advertencias ya deben haberse colocado cuando se complet la instalaci n inicial del artefacto Si no est n colocadas en estos lugares encuentre las etiquetas adhesivas multiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encendi ndolo y apag ndolo Limpie bien la superficie del panel de control para quitar el polvo y aceite Pegue la etiqueta adyacente al interruptor de control del quemador que controla el artefacto Figura A Seleccione el idioma que m s se habla en la casa Si no sabe cu l es use la etiqueta en ingl s 2 ldentifiqueeltransmisordecontrol remoto y limpielo bien para quitar el polvo y aceite Pegue la etiqueta enlasuperficie deltransmisor Figura B Seleccione el idioma que m s se habla en la casa Si no sabe Cu l es use la etiqueta en ingl s 3 Si no puede encontrar las etiquetas s rvase llamar a Innovative Hearth Products o al distribuidor de Innovative Hearth Products m s cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas
52. eft Side View Front View Right Side View Figure 2 Insert Dimensions Minimum Fireplace Opening A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height 18 457mm Rear Width 16 406mm Fireplace Depth Figure 3 Minimum Fireplace Cavity NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 14 CLEARANCES TO COMBUSTIBLES Minimum Clearances to Combustibles Minimum clearances include any projections such as shelves window sills mantels spacers standoffs orsurfacesto combustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters in Figure 5 A through E show minimum clearances required from the appliance to combustibles and the minimum projection of the hearth extension Insert Leveling At each front and rear corner of the insert is an adjustable leg provided to level the insert should the hearth of the fireplace be uneven To adjust the legs loosen the two 5 32 allen head screws move the leg to the desired height and then tighten the screws Repeat these steps for each adjusting leg Facing and Mantel Clearances See Figure 4 MINIMUM CLEARANCES TO COMBUSTIBLES A Top Facing to Bottom of Appliance 31 1 2 800mm B Side Facing or Side Wall to Center of Glass 25 1 2 648mm 10 1 2 267mm Mantel to Bottom of Appliance 39 991mm RDV CD HEARTH PROTECTION 2 D Vertical
53. ent are not covered by this warranty All replacement or repair components will be shipped F 0 B from the nearest stocking IHP factory y LIMITATION ON LIABILITY It is expressly agreed and understood that IHP s sole obligation and the purchaser s exclusive remedy under this warranty under any other warranty expressed or implied or in contract tort or otherwise shall be limited to replacement repair or refund as specified herein In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product whether such damage occurs or is discovered before or after gt repair or replacement and whether such damage is caused by IHP s negligence IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose and there is no implied condition of fitness for a particular use or purpose IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty The duration of any implied warranty is limited to the duration of this expressed warranty No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you The provisions of this 20 Year SOS Limited Warranty are in addition to and not a modification of or subtrac
54. for requirements in your area THE FIREPLACE INSERT Must conform with all local state and national installation codes In theabsence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 In Canada the current CAN CGA B149 1 installation code Refer to the National Fuel Gas Code and local zoning and code authorities for details on installation requirements Manufactured home installations USA only must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 or Standard for Gas Equipped Recreational Vehicles and Mobile Housing CSA 2240 4 Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance Has been certified for use with either natural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace built to UBC 37 or ULC S628 standards or factory built solid fuel wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be
55. g both sides firmly and lifting up slightly and then out away from the unit Lay the facade face down on a soft surface that will not scratch the paint Using a 3 8 socket remove the six nuts holding the left 1 and right 2 sight obstructer Remove the barrier Installation is the reverse of removal 4 Replace barrier with Part No J7510 Place sight obstructers back over the threaded studs taking note that the upper and lower horizontal bar ends line up with grooves in sight obstructers see Detail A in Figure 29 Reinstall the 3 8 nuts Reinstall facade to the unit Cast Pillar Facade see Figure 30 Make sure the unit is off and cold Remove the cast pillar facade door from the facade by gripping both sides firmly and lifting up slightly and then out away from the side pillars Lay the door face down on a surface that will not scratch the paint Using a Phillips head screwdriver remove the 18 screws holding the barrier to the door Remove the barrier Installation is the reverse of removal 1 2 3 4 Replace barrier with Part No J7511 Replace all Phillips head screws removed in step 5 Replace the four socket head screws removed in step 4 Reinstall door onto facade Barrier _ UN Figure 30 Pillar Cast Facade NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 29 30 TROUBLESHOOTING NOTE When troubleshooting
56. gneusementlasurface surle panneau de contr le pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette c t du bouton de contr le du br leur qui contr le l appareil Figure A Choisissezlalangue quiestprincipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commande et nettoyez la soigneuse ment pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le boitier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 3 Sivous ne parvenez pas localiser les tiquettes s il vous plait contactez IHP ou votre revendeur le plus proche pour recevoir IHP tiquettes d instructions de s curit suppl mentaires gratuitement Etiquettes de remplacement n cat H8024 IHP IronStrike us com Remargue Le texle anglais est rouge sur un support transparent Le texte fran ais et espagnol est blanc sur un support noir DIAGRAMMES DES TIQUETTES DE S CURIT AVERTISSEMENT Vitre et foyer EXTREMEMENT CHAUDS Risque de br lures graves Toujours tenir les enfants l cart du foyer gunner TOTAL coMFORT CONTROL COLOCACI N DE ADVERTENCIAS DE SEGURIDAD EN OPERACI N Se requiere que el juego de etiquetas de instrucciones de seguridad que se incluyeron con la art
57. h is red text on clear label French and Spanish are white text on black label SAFETY LABEL DIAGRAMS WARNING EXTREMELY HOT glass and fireplace Risk of Severe Burns ALWAYS KEEP CHILDREN AWAY FROM FIREPLACE Figure A APPOSITION DES MISES EN GARDE RELATIVES ALA SECURITE D UTILISATION Votre appareil a t livr avec des tiquettes de s curit qui doivent tre coll es c t des dispositifs de contr le du br leur Une tiquette de s curit devrait tre coll e sur laplaquedur cepteurcontr lantl allumage de l appareil voir Figure A et sur le boitier de la t l commande Figure B Les mises en garde auraient d tre coll es au moment de l installation initiale de l appareil Si ce n est pas le cas prenez les tiquettes adh sives multilingues fournies avec ces instructions et proc dez comme suit 1 Rep rezle contr leur sur le panneau de contr le de votre appareil v rifiez que l interrupteur contr le le fonctionnement de l appareil en le faisant basculer de Marche Arr t et vice versa Nettoyez soigneusementla surface sur le panneau de contr le pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette c t du bouton de contr le du br leur qui contr le l appareil Figure A Choisissezlalangue quiest principalement parl e dans la r sidence du propri taire 2 Rep rezlat l commande et nettoyez la soigneuse ment pour liminer la poussi re et
58. he flexible vent pipe must NOT be allowed to sag behind insert or in fireplace flue Combustion Air Intake Figure 7b Make sure that both liners will pass through existing damper area Remove or lock damper to allow the passage of the flexible liners If the damper will notallow the passage of both liners DO NOT PROCEED FURTHER If fireplace is masonry Consult a local mason for removal of the damper without risk of structural damage or leakage if the fire place is factory built The appliance may NOT be installed into the fireplace WARNING Direct VentFireplace Insert Vent Requirements Use liner listed to UL181 Factory made Air Ducts And Air Connec tors or UL1777 Chimney Liners forthe AIR INTAKE Use liner listed to UL1777 ONLY for the EXHAUST Do not substitute the heat rated flex liner UL1777 for the exhaust with any other type liner or a fire may result causing property damage personal injury or loss of life NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Zero Clearance Fireplace Installation This appliance may be installed in a masonry or factory built zero clear ance ZC fireplace When installing in a ZC fireplace the ZC grate must be removed and the ZC damper must be removed or secured open The ZC doors screen refractory or masonry lining baffles and smoke shelf may be removed if necessary to install the gas insert However do not cut or alter the fireplace components The removal of an
59. is appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 3 Due to high temperatures the appli ance should be located out of traffic and away from furniture and draperies 4 Children and adults should be alerted to the hazards of high surface tem perature and should stay away to avoid burns or clothing ignition 5 Clothing or other flammable material should not be placed on or near the appliance 6 Young children should be carefully supervised when they are in the same room as the appliance Toddlers young children and others may he sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces 7 Any safety screen guard or barrier removed for servicing an appliance must be replaced prior to operating the appliance 8 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a profes sional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that cont
60. ive wire restraints Installation and Operation Manual Remote Control Glass Media Measuring Box Black Porcelain Panel Set One Required Decorative Facade Kits One Required Contemporary Facade Cast pillar Facade Surround Kits One Required Traditional 1 pc 41 W x 29 H Traditional 3 pc 41 W x 29 H 48 W x 29 H 41 W x 33 H or 48 W x 33 H Cast Iron 45 1 2 W x 30 H Cast Pillar Facade only See detailed dimensions on Page 34 Surround Kit Contents 1 Top Surround 2 Side Surrounds 3 Black Extruded Trim Pieces 2 Elbowed Trim Fasteners Media Kits One Required Reflective Black Glass Media Reflective Blue Glass Media Platinum Glass Media Goldfinger Glass Media Copper Glass Media RAVENNA CD RDV CD LP GAS O Unit factory equipped for 0 2000 FT 0 610 M In Canada 0 4500 FT 0 1370 M GO Tested to CSA P 4 1 09 Testing Method for Measuring Annual Fireplace Efficiency Electrical Rating 120 VAC 60 HZ Less Than 2 Amps ENER QUIDE Look for the EnerGuide Gas Fireplace Energy Efficiency Rating in this brochure Based on CSA P 4 1 09 ENERCHOICE ORG 31 1 4 i 794mm 0 0 2 15 16 75mm 13 3 8 340mm Top View 15 7 8 403mm L
61. juries do Not remove the barrier on the facade required accessory which prevents direct contact with the glass Follow the safety instructions below and be sure everyone in your household understands this burn hazard The surfaces on your fireplace get EXTREMELY HOT The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched Keep children away from an operating fireplace Closely supervise children in any room where a fireplace is operating to prevent contact with glass Keep clothing furniture gasoline and other flammable liquids away from the fireplace Even after the gas is turned off fireplace surfaces remain extremely hot Be sure to attach the enclosed Safety in Operation Warnings where you turn on your fireplace to help remind everyone of the dangers associated with high temperatures see pages 6 7 Read Important Safety Information on page 5 ENGLISH La s curit et votre Seguridad y su po le encastrable Toutes les parties de votre po le encastrable IHP deviennent EXTREMEMENT CHAUDES Afin d viter les br lures graves ou les blessures ne pas retirer l cran de protection de la face avant accessoire obligatoire qui emp che tout contact direct avec la vitre Suivez les instructions de s curit ci dessous et veillez ce que tous les membres de votre famille soient conscients du danger de br lure
62. justed through six 6 speeds To activate this function use the Mode Key to index to the blower control icon see Figures 22 and 23 Use the Up Down Arrow keys to turn on off or adjust the blower speed A single beep will confirm reception of the command NOTE The blower can be controlled only by the remote Turning the appliance off with the unit mounted three position slider switch Figure 21 will NOT turn off the blower To turn off the blower use the remote in lieu of or prior to shutting the appliance off at the three position slider switch Figure 21 Blower speed will be indicated by either an Off Level Bar or HI shown in the Set Point Temp Level State indicator area Key Lock This function will lock the keys to avoid unsupervised operation To activate this function press the MODE and UP keys at the same time To de activate this function press MODE and UP Keys at the same time Manual Bypass Of The Remote System If the batteries of the Receiver or Remote are low or depleted the appli ance can be turned on manually by sliding the three position slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on OPERATION RDV CD Flame Color and Behavior This appliance is designed for maximum heating efficiency Therefore upon lighting of the main burner the flames will be semi transparent or bluish After 10 20 minutes of operatio
63. lve Massachusetts Horizontal Vent Requirements Inthe Commonwealth of Massachusetts horizontal terminations installed less than seven 7 feet above the finished grade must comply with the following additional requirements A hard wired carbon monoxide detector with an alarm and battery back up must be installed on the floor level where the gas fireplace is installed The carbon monoxide detector must comply with NFPA 720 be ANSI UL 2034 listed and be ISA certified A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade and be directly in line with the horizontal termination The sign must read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS NEW YORK CITY NEW YORK MEA Installation of these appliances are approved for installation in New York City in the US state of New York MEA 138 07 E 11 12 PRE INSTALLATION Features Installation Options Manufactured Mobile Home Natural Gas Or Propane LP Bedrooms Electrical The standard blower motor requires 120 Volts AC for operation The fireplace is not dependent on the blower to operate WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle
64. n or door tracks log grates refractory or masonry lining and damper assemblies Any fireplace component whichis removed mustbe retained so they can be reinstalled to restore the fireplace to its original operating condition The removal of any part must not alter the integrity ofthe outer shell of the pre engineered fireplace cabinet in any way Any parts removed must be replaceable If any components are removed from or altered from the existing fireplace a Warning Label see Figure 1 must be affixed inside the fireplace firebox so that it shall be visible upon removal of the fireplace insert Note RTV high temperature silicone is an approved adhesive to affix the label WARNING THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO RE USE AS A CONVENTIONAL FIREPLACE Figure 1 Fireplace Warning Label CODES AND APPROVALS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and Canada This appliance has met all necessary ANSI Standards and is fully certified for installation in any communit
65. n the insert will heat up and the flames will become a yellow orange color Adjusting the appliance to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 26 showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually determine that main burner gas is burning properly i e no floating lifting or flashback Adjust the primary air shutter s as required Check for proper main burner operation at both high and low flame Burner Flame Appearance Soot above Flame Tip Soot at Flame Tip No Soot at Flame Tip Dark Orange Flame Semi Transparent Yellow Flame Blue Flame Center PROPERLY BURNING FLAME Ports on Pan Burner Assembly No Blue Flame Center IMPROPERLY BURNING FLAME Figure 26 Paint Curing This appliance has been painted with a high temperature metallic stove paint It leaves the factory dry to the touch but finishes curing as the appliance is used Firethe appliance four successive times forten minutes each time with a five minute cool down between each firing Ventilate the house during these first firings as the paint gives off an unpleasant odor It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the appliance during the curing process Quiet Operation As the appliance is burning a number of norm
66. ndre cing 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si vous sentez une odeur de gaz ARR TEZ Passez l tape B des instructions de s curit sur la portion sup rieure gauche de cette tiquette S il n y a pas d odeur de gaz passez l tape suivante Mettez l appareil sous tension Mettre l interrupteur du br leur ON OFF dans le compartiment de contr le ON Attendre 4 secondes Le syst me d allumage produira des tincelles pendant 60 secondes afin d amorcer le br leur principal Si l appareil ne se met pas en marche suivez les instructions intitul es Comment couper l admission de gaz de l appareil et appelez un technicien qualifi ou le fournisseur de gaz MMENT COUPER L ADMISSION DE GAZ DE L APPAREIL Mettre l interrupteur du br leur ON OFF situ dans le 2 Couper le courant l appareil si un entretien doit tre compartiment de contr le OFF perform e 3 Fermer la valve de gaz principale DANGER VITRE CHAUDE RISQUE DE BRULURES NE TOUCHEZ PAS UNE VITRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personnes risques incluse avec le fa ade Requis OPERAT
67. olors styles and products Consult your local distributor for fireplace code information P90 Printed in U S A 2014 Innovative Hearth Products P N 900124 00 REV A 01 2015 2 01 4 00 Propane Gas LP NATIONAL FIREPLACE INSTITUTE NFI Nous recommandons que nos foyers au gaz soient install s et que l entretien soit effectu par des profes sionnels certifi s par le National Fireplace Institute CERTIFIED NFI Etats Unis seulement www nficertified org TM INNOVATIVE HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 e Nashville TN 37210
68. on monoxide poisoning WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 10 ORIFICE SIZE ALTITUDE ADJUSTMENT For altitudes above 2 000 feet In Canada 4 500 FT 1370 M the orifice should be de rated by 4 for every 1 000 feet to maintain the proper ratio of gas to air Improper orifice sizing may result in damage and unsafe conditions Changing the orifice should only be done by a qualified service technician Contact your IHP dealer for proper orifice sizes In Canada CAN CGA 2 17 M91 R2009 high altitude THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER S AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIRE MENTS OF THE MANUFACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN CGA B149 1 OR CAN CGA B149 2 INSTALLATION CODES SMOKE DETECTORS Since there are always several potential sources of fire in any home we recommend installing smoke detectors If possible install the smoke detector in a hallway adjacent to the room to reduce the possibility of occasional false activation from the heat produced by the appliance If your local code requires a smoke detector be installed within the same room you must follow the requirements of your local code Check with your local building department
69. ones son s lo ejemplos Tu accesorios pueden ser diferentes NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE INSTALLER INSTRUCTIONS ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation These warning labels are a critical step in informing consumers of safe operation of this appliance ATTACHING SAFETY IN OPERATION WARNINGS It is required that the set of safety instruction labels that have been furnished with the appliance be affixed tothe operation and control points ofthe appliance A safety instruction label should be affixed next to the burner control switch where the appliance is turned on and off See Figure A and the remote control handheld transmitter See Figure B To properly complete the installation of this appliance locate the multi lingual adhesive labels provided with these instructions and proceed as follows 1 Locate the control switch on the control panel of your appliance verify the switch operates the appliance by turning it on and off Clean the surface onthe control panel thoroughly to remove any dust and oils Affix the label next to the burner control switch that controls the appliance Figure A Choose the language primarily spoken in the home If unknown affix the English language label 2 Locate the remote control transmitter and clean it thoroughly to remove any dust and oils Affix the label to the surfac
70. or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Remote Smart Thermostat Remote Operation The smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key until the word SMART appears to the right of the temperature bulb graphic To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Remote see Figure 23 Child Safety Lock Out Low Battery Alarm Transmission rx a o Thermostat i F LIE i C Room Temperature Off On Smart Set Point Temp Level State Flame On AS Blower Control MAX Maximum Level Indicators Figure 23 Indicator Icons i Flame Level 5 amc F la Figure 24 Flame Level Maximum Figure 25 WARNING THE REMOTE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE OPERATION RDV CD Blower Speed Control This appliance is equipped with a hot air circulating blower The speed of the blower is controlled by the Remote The blower speed can be ad
71. ot run propane tank dry Running the tank dry may cause a hazardous condition due to pressure drop in empty tank Solid fuel is NOT to be used with this unit NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Air Shutter Adjustment This appliance has an air shutter adjustment lever located behind the lower door of the inserts face directly above the gas valve see Figures 17 and 18 The lever is linked to the primary air shutter on the main burner The air shutter regulates the amount of primary air the burner receives and therefore how clean the insert burns The air shutter should only be adjusted by a qualified gas technician The insert should burn for about 15 minutes with the glass media installed before adjusting the air shutter More air will result in shorter flames and less color less air will result in bigger flames and more color To adjust the air shutter move the adjustment lever toward or away from you using a screw driver or needle nose pliers see Figures 17 and 18 CAUTION The air shutter should never be set so as to make the tips of the flames sooty or create sooting on the viewing glass glass media or firebox panels If soot begins to form after burning the air shutter should be opened gradually until the sooting condition stops Gas quality and gas pressure may vary which can affect the burning characteristics of the insert
72. r of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product ONG IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems mechanical ventilation systems or general construction conditions which may generate negative pressure in the room in which the appliance is installed Additionally IHP assumes no responsibility for drafting conditions caused by venting configurations adjoining trees or buildings adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit This 20 Year Limited Warranty covers only parts and labor as provided herein In no case shall IHP be responsible for materials components or construction which are not manufactured or supplied by IHP or for the labor necessary to install repair or remove such materials components or construction Additional utility bills incurred due to any malfunction or defect in equipm
73. raturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamables alejados de la chimenea A n despu s de haber apagado el gas las superficies de la chimenea permanecen extremadamente calientes Aseg rese de colocar las Etiquetas de advertencia de seguridad de operaci n en el lugar donde enciende la chimenea para que todos recuerden los peligros asociados con las altas temperaturas ver la p ginas 6 7 Lea la Informaci n importante de seguridad en la p gina 5 SPANISH CONGRATULATIONS When you purchased your new gas fireplace insert you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new gas fireplace insert Thank you for selecting an Innovative Hearth Products LLC IHP gas fireplace insert as the answer to your home heating needs TABLE OF CONTENTS Safety and Your Fireplace Insert 2 3 Using this Manual
74. rol compartments burners and circulating air passageways of the appliance be kept clean See mainte nance instructions on Pages 27 29 L information de s ret importante 1 AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en place est craqu ou bris 2 Ne pas se servir de cet appareil s il a t plong dans l eau m me partiellement Faire inspecter l appareil par un technicien qualifi et remplacer toute partie du syst me de contr le et toute commande qui ont t plong es dans l eau 3 En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures 4 Les enfants et les adultes devraient tre inform s des dangers que posent les tem p ratures de surface lev es et se tenir distance afin d viter des br lures ou que leurs v tements ne s enflamment 5 On ne devrait pas placer de v tements ni d autres mati res inflammables sur l appareil ni proximit 6 Les jeunes enfants devraient tre surveill s troitement lorsqu ils se trouvent dans la m me pi ce que l appareil Les tout petits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une ba
75. rri re de s curit cette mesure emp chera les tout petits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes 7 Tout cran ou protecteur retir pour per mettre l entretien de l appareil doit tre remis en place avant de mettre l appareil en marche 8 L installation et la r paration devrait tre confi es un technicien qualifi L appareil devrait faire l objet d une inspection par un technicien professionnel avant d tre utilis et au moins une fois l an par la suite Des nettoyages plus fr quents peuvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les conduits de circulation d air de l appareil soient tenus propres Voyez les instructions d entretien la Pages 27 29 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Informaci n importante de seguridad 1 ADVERTENCIA No opere el artefacto con el frente de vidrio quitado agrietado o roto 2 Nouse este artefacto si alguna de sus partes ha estado bajo agua Llame de inmediato a un t cnico de servicio calificado para que inspeccione el artefacto y reemplace cualquier parte del sistema de control y cualquier control de gas que haya estado bajo agua 3 Debido a las altas temperaturas el artefacto debe situarse fuera de las reas de tr fico y lejos del mo
76. sition Ensure the igniter lights the pilot The pilot flame should engulf the flame sensor as shown in Figure 28 See Intermittent Standing Pilot Mode on Page 22 for instructions on switching from intermittent ignition to a standing pilot O Periodically inspectthe burner flame for proper appearance See Flame Color and Behavior on Page 25 L1 Check that the area around the insert is kept clear and is free of combustible materials gasoline and other flammable vapors and liquids 2 The viewing glass should be cleaned periodically see Glass Main tenance Proper Pilot Flame Appearance Flame Sensor Igniter Electrode Figure 28 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 21 Glass Door Cleaning and Maintenance Cleaning Do not remove or clean the glass door when hot When cool the glass may be cleaned with a clean soft cloth and a household glass cleaner For cleaning white condensation from the interior glass use a gas fireplace glass cleaner available from your dealer Use of caustic or abrasive cleaners may damage the glass DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dis solve the gasket glue WARNING e DO NOT use abrasive cleaners on glass e DO NOT clean glass when hot Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced as a unit This replacement glass door is available from your
77. t etc When the Receiver batteries are low two beeps will be emitted from the Receiver when it receives an ON OFF command from the Remote This is an alert for a low battery condition for the Receiver When the batteries are replaced the beep will be emitted from the Receiver when the ON OFF key is pressed See Initializing The System WARNING Fire hazard Can cause severe injury or death The receiver causes ignition of the appliance The appliance can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system Receiver ON REMOTE OFF LU QU DU ON AUTO Pilot Figure 21 Control Compartment Blue LCD Display THERMOSTAT Key UP DOWN Arrow Key MODE Key Figure 22 Remote transmitter CAUTION Property damage hazard Excessive heat can cause property damage The appliance can stay lit for many hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it 23 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE OPERATION RDV CD Temperature Indicator Display With the system in the OFF position press the Thermostat Key and the Mode Key at the same time see Figure 22 Look at the LCD screen on the Remote to verify that a C or F is visible to the right of the Room Temperature display see Figure 23
78. t to cool before cleaning or servicing the appliance CAUTION Wear gloves and safety glasses for protection while doing required maintenance Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin Maintenance Checklist The following should only be performed by a qualified service technician 1 Annual inspection should be made and the following checks per formed L1 When unit is cool remove glass and inspect burner for dirt soot and lintaccumulations and remove if necessary Before cleaning the burner remove and clean the media following the instructions on Page 28 If excessive soot accumulation is present on burner have a qualified service technician adjust the burner for proper combustion Ll Clean inside of glass with gas fireplace glass cleaner NEVER attempt to remove or clean the glass when the unit is hot L1 Check the hot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance L1 Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified agency L1 Check gaskets once a year Gaskets must be tight Replace if necessary Ll Periodically inspect the pilot system for proper flame Turn the pilot ON Auto switch to the ON po
79. the gas control system be sure the external gas shut off valve located at the gas supply inlet is in the ON position IMPORTANT Call your gas supplier or plumber for additional help with any gas control problem Valve system troubleshooting should only be accomplished by a qualified service technician SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating soot forms on the viewing glass firebox panels or glass media Humming or whistling coming from insert A change in flame appear ance or burner operation The main Burner comes on but then goes out Nothing happens when the appliance is turned On Off The main burner does not light and the igniter is sparking Too much or improper placement of glass media Improper air shutter setting Not enough combus tion air Normal operating noise Obstructed orifice opening A change in gas pres sure Too much or improper placement of glass media Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent system Gas is not reaching the appliance Appliance is not receiv ing power Gas is not reaching the appliance Loose wires to the valve Loose wires to ignition module Air in the gas line See Firebox Liner Kit and Glass Media Installation on Pages 18 and 19 If sooting continues open air shutter see Air Shutter Adjustment on Page
80. tion from any statutory warranties and other rights and remedies provided by law INVESTIGATION OF CLAIMS AGAINST WARRANTY reserves the right investigate any and all claims against this 20 Year Limited Warranty and to decide in its sole discretion upon the method of settlement To receive the benefits and advantages described in this 20 Year Limited Warranty the appliance must be installed and repaired by a licensed contractor approved by IHP Contact IHP atthe address provided herein to obtain a listing of approved dealers distributors IHP shall in no event be responsible for any warranty work done by a contractor that is not approved without first obtaining IHP s prior written consent SS HOW TO REGISTER A CLAIM AGAINST WARRANTY AN In order for any claim under this warranty to be valid you must contact the IHP dealer distributor from which you purchased the product If you cannot locate the dealer distributor then you must notify IHP in writing IHP must be notified of the claimed defect in writing within 90 days of the date of failure Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike Suite 108 Nashville TN 37210 or visit our website at WWW IRONSTRIKE US COM ASS ON 2 II M 7 227 Printed in U S A 2013 Innovative Hearth Products LLC Innovative Hearth Products P N 900197 00 Rev NC 12 2013 1508 Elm Hill Pike Suite 108 e Nashville TN 37210 38 PRODUCT REFERENCE INFORMATION
81. trim pieces should now be horseshoe shaped Slide the trim down over the surround panels so the edge of the surround panel fits just behind the rounded edge of the trim Install three spring clips found in parts bag in firebox in each piece of trim by inserting them between the rear of the surround and the channel of the trim The spring clips will push the trim tight to the surround Speed nuts Latches B Holes in the surround brackets three on each side Figure 15 Location where hooked brackets on face will hang Face Installation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets See C in Figure 15 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 19 Gas Line Installation After leveling position the insert in the fireplace holding it about six inches out from its final location CAUTION Specific hearth requirements apply see Clearances to Combustibles This appliance must be connected to the gas line in accordance with local codes and or the National Fuel Gas Code ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code This appliance comes with an 8 nipple provided in the literature package After connecting the gas line all joints in the line and connections at the valve should be checked for leaks before final positioning
82. uler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Si un l ment de cette unit ne fonctionne pas tel que d crit dans les instructions n essayez pas de le r parer appelez un technicien qualifi N utilisez pas d outils Le fait de forcer la manette ou de la r parer peut d clencher une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau INSTRUCTIONS DE MISE EN MARCHE ARR TEZ Lisez les avertissements de s curit l endos de cette Electronic ASR tiquette Gas Control 2 Lire la section op ration du manuel d instructions et d op ration Mettre l interrupteur du br leur ON OFF situ dnas le roflame aa compartiment de contr le OFF Coupez l alimentation lectrique de l appareil Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement Atte
83. use the door is hot during operation Intermittent Standing Pilot Mode On Auto Pilot Mode Switch This appliance can be switched from intermittent ignition to a standing pilot simply by toggling the switch located in the lower control compartment refer to Figure 20 To save energy switch to intermittent mode To have a standing pilot which will help startup during cold climate conditions by warming the flue and the glass switch to standing pilot The standing pilot mode is indicated by a pilot that comes on and remains lit when the fireplace is off WARNING e Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide CO poisoning and possible death Electronic Pilot Assembly Electronic Gas Control Valve SIT Proflame Stepper Unit Mounted Controls Figure 20 RDV CD NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE OPERATION RDV CD Remote Control System The Remote and Receiver allows you to command the functions of your appliance from the comfort of your chair and is configured to control the On Off primary burner operation its flame levels through six levels and provides On Off and Smart thermostatic control of the appliance The system controls blower speed through six 6 levels and has a constantly powered 120V 60Hz power outlet The Receiver connects directly to the gas valve stepper motor and the Blower Control Module
84. with and umbilical cord wiring harness see Wire Diagram on Page 26 The Receiver accepts commands via radio frequency from the Remote transmitter and does not require line of sight operation The Receiver three position slider switch can be set to one of three posi tions ON Manual Override REMOTE Remote Control or OFF Initializing The System For The First Time Install 4 AA batteries into the receiver battery bay behind the switch plate Note the polarity of the battery and insert into the battery bay as indicated on the Battery cover 4 Place the 3 position slider switch in the Remote position see Figure 21 Using the end of a paper clip or other similar object insert the end of the paper clip into the hole marked PRG on the Receiver front cover The Receiver will beep three 3 times to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already installed in the Remote push the ON button The Receiver will beep four times to indicate the Remote s command is accepted and sets to the particular code of that Remote The system is now initialized Low Battery Power Detection The life span of the Receiver batteries depends on various factors quality ofthe batteries used the number of ignitions of the appliance the number of changes to the room thermostat set poin
85. xed to the operation and control points of the appliance per the instructions on Page 7 It is the installers responsibility to ensure these warnings are properly affixed during installation These warning labels are a critical step in informing consumers of safe operation of this appliance NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE OPERATION Pre Lighting Checklist Be sure to check these items before the initial lighting of the insert Gas pressure has been checked carefully see Page 20 All gas fittings have been checked for leaks All clearances to combustibles have been met see Page 14 All combustible materials have been removed from the area in front of the insert All vented areas of the insert face are unobstructed House is ventilated to clear initial paint curing odors see Page 25 All packaging materials have been removed from the firebox While appliance is cool fingerprints or other marks have been cleaned from any plated surfaces with denatured alcohol anda soft cloth Marks lefton these surfaces may become permanent into the finish if not removed prior to burning the unit _ Firebox liner panels and glass media have been installed The glass door is in place and is properly sealed Operating Instructions See Page 36 for operating instructions IMPORTANT NOTE When opening the lower door on the face while the insert is burning pull at the far left or far right vent openings beca
86. y If there are any questions or if you need further substantiation contact your IHP dealer If you have further questions please contact IHP Check all local building and safety codes before installation The instal lation instructions and appropriate code requirements must be followed exactly and without compromise In the absence of local codes the fol lowing standards and codes must be followed The Installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Installation Code CAN CGA B149 1 latest edition The appliance when installed must be electrically grounded and wired in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M R Sections 4 00 through 8 00 Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shut off must be a T handle type va
87. y parts to facilitate installation must not alter the integrity of the inner or outer shells of the fireplace cabinet Any parts removed must be replaceable if the insert is taken out of the fireplace or the fireplace clearly marked with a paint stick that This fireplace has been altered and is no longer safe to operate This appliance is designed to fit into a ZC fireplace with a minimum firebox height of 19 1 2 495mm If the factory built fireplace has no gas access hole s provided an access hole of 1 5 38 1 mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with a non combustible insulation after the gas supply line has been installed Si le foyer pr fabriqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 38 1 mm 1 5 po peut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustion Cet orifice doit tre obtur au moyen d isolant incombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed See Figure 1 on Page 10 Glass Door WARNING Do not attempt to substitute the materials used on these doors or replace cracked or broken glass e Handle this glass with extreme car
Download Pdf Manuals