INSTALLATION & OPERATION MANUAL
Contents
1. ENTRETIEN DU VERRE AVERTISSEMENT N UTILISEZ PAS DE MATERIAUX DE REMPLACEMENT SEUL DU ROBAX PYROCERAM D UNE TAILLE ET D UNE EPAISSEUR ADEQUATES ET RESISTANT A DES TEMPERATURES ELEVEES PEUT REMPLACER LE VERRE Respectez les conseils d utilisation et de s curit ci dessous 1 V rifiez r guli rement l absence de fissures ou de cassures sur le verre Si vous d tectez une fissure ou une cassure teignez imm diatement le feu et prenez contact avec votre concessionnaire ou le service client le au 800 245 6489 pour en obtenir le remplacement ou allez sur le site www englanderstoves com 2 Ne claquez pas la porte et ne causez pas d impact sur la vitre En fermant la porte assurez vous que les b ches ou les autre objets ne d passent pas et ne peuvent pas heurter la vitre 3 Ne nettoyez pas la vitre avec des mat riaux susceptibles de rayer ou d endommager le verre Des rayures sur le verre peuvent se transformer en fissures ou en cassures 4 N essayez jamais de nettoyer la vitre pendant que le po le est chaud Si les d p ts ne sont pas tr s pais les produits courants de nettoyage pour vitres conviennent avec un tampon r curer simple non abrasif Les d p ts plus pais peuvent tre limin s avec un produit de nettoyage pour fours 5 NE JAMAIS mettre dans le po le de substances susceptibles de s enflammer explosivement car m me de petites explosions dans une enceinte confin e peuvent fai
2. CUSTOMER SERVICE DEPARTMENT P O BOX 206 MONROE VA 24574 Technical Questions Customer Service 800 245 6489 Fax 434 929 4810 Parts orders only 800 516 3636 Email service englanderstoves com 21 DIRECTIONS FOR INSTALLATION OF LEGS OR PEDESTAL Stove must be cooled and all ashes cleaned out Remove bricks disconnect flue and turn stove on its back If you are replacing existing legs or pedestal disconnect the existing legs or pedestal To install legs 1 Each leg will fit into a pre made slot on each corner of the bottom of the unit 2 3 8 x 1 1 2 Carriage Bolt and matching nut is supplied with each leg Fit a leg into a slot and match the hole on the leg with the hole in the slot Attach the legs one ata time using the supplied bolts and nuts Tighten securely To install pedestal 1 Place spacers provided between the slots on the unit and the pedestal base one spacer will fit on each side of the pedestal Match the four holes in the pedestal 2 on each side with the holes in the spacers and slots on the unit ASSEMBLY NN 2 Use the four 3 8 x 1 1 2 Carriage Bolts and nuts N N provided to attach the pedestal to the base of the stove Tighten securely Illustration 6 Base Options and Details After attaching the legs or pedestal turn unit upright reconnect flue and replace bricks according to manual NOTES 22 TH b rik 1 il You may write your unit s Manu
3. 4 x 2 2 x 11 4 brick Qty 1 4 Metal plate Ash Drawer Plate Qty 1 STANDARD AC 16 BLOWER Install AC 16 Blower here using the 4 supplied mounting screws ROOM AIR BLOWER MODEL AC 16 120 VOLTS 60Hz 0 75 AMPS 2900 RPM DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT ALWAYS FOLLOW ALL CODES AND OWNER S MANUALS BLOWER MOTOR OPERATING INSTRUCTIONS This unit is set up for installation of an optional 2 speed blower motor The fan speed should be run on Low when the unit is operating at lower burn settings and set to High for high burns When routing the power cord be sure that the cord does not come into contact with any hot surface The optional heat circulation blower on this stove requires periodic lubrication this lubrication should be performed no less than every three months of normal operation To properly lubricate the blower use an eye dropper or similar dispensing device to drip 5 7 droplets of SAE 20 oil into the oil port on the side of the blower motor OPTIONAL AC 30 BLOWER There is a larger optional blower available OPTIONAL BLOWER MODEL AC 30 120 VOLTS 60Hz 0 75 AMPS 3000 RPM DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT OPTIONAL BLOWER MOTOR OPERATING INSTRUCTIONS This unit is set up for installation of a variable speed optional blower motor The fan speed should be run on Low when the unit is operating a
4. 4 This appliance requires a masonry or prefabricated chimney listed to ULC S629 Canada and UL103HT U S sized correctly 5 A 6 diameter flue is required for proper performance 6 Always connect this unit to a chimney and NEVER vent to another room or inside a building 7 DO NOT connect to any duct work to which another appliance is connected such as a furnace 8 DO NOT connect this unit to a chimney flue serving another appliance 9 DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE 10 The connector pipe and chimney should be inspected periodically and cleaned if necessary 11 Remember the clearance distances when you place furniture or other objects within the area DO NOT store wood flammable liquids or other combustible materials too close to the unit 12 Contact your local fire authority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire In the event of a chimney fire turn air control to a closed position and CALL THE FIRE DEPARTMENT 13 DO NOT tamper with the combustion air control beyond normal adjustment 14 Once the required draw is obtained operate only with doors closed open doors slowly when re fueling this will reduce or eliminate smoke from entering the room 15 Visit our web site at www englanderstoves com for helpful information frequently asked questions parts accessory orders and more Customer Service 800 245 6489 Note on Outside Air
5. Pour retirer les cendres du po le les extraire des briques r fractaires avec une pelle Ce po le est muni d une plaque cendrier voir l illustration 4 qui peut tre retir e une fois retir e on peut faire tomber les cendres dans le bac cendres par l ouverture MISE EN GARDE La plaque cendrier peut tre extr mement chaude N enlevez jamais de cendres chaudes encore rouges de cet appareil laissez les cendres refroidir avant de les faire tomber dans le bac cendres Les cendres doivent tre mises dans un r cipient en m tal avec un couvercle tanche Ces cendres doivent tre mises sur une surface non combustible compl tement l cart de tous mat riaux combustibles Les cendres doivent rester dans le r cipient tanche jusqu ce qu elles aient compl tement refroidi 19 IMPORTANT CONSEIL ET ASTUCES UTILES Quelle est la bonne mani re d allumer un feu Vous aurez besoin de petits morceaux de bois bois d allumage et de papier N utilisez que du papier journal ou du papier non glac ou sur lequel rien n a t coll ou appliqu N utilisez jamais de papier glac ou colori prospectus publicitaires entre autres Ouvrez la porte du po le Froissez plusieurs morceaux de papier et mettez les au milieu du foyer directement sur les briques r fractaires du po le Ne sur levez jamais le feu a l aide d une grille Mettez de petits morceaux de bois bois d allumage sur le papier en forme de lt
6. 508 mm 356 mm 381mm 305mm 305mm a n E nam ANS LATERAUX ET ARRI RE 533 mm 203 mm 356mm 305 mm 203 mm AACCORD DE CHEMIN E SIMPLE PAROI 21 po 8 po 14 po 12 po 8 po ECRANS LATERAUX ET ARRI RE 508 mm 427mm 356 mm 305 mm 127 mm S ACCORD A DOUBLE PAROI 20 po 5 po 14 po 12 po 5 po NOTE RACCORD DU CONDUIT 1 RACCORD A PAROI SIMPLE AVEC CRAN ARRI RE 406 mm 16 po AU MUR ARRIERE C 2 RACCORD PAROI SIMPLE AVEC ECRANS ARRI RE ET LATERAUX mm 10 po 3 RACCORD PAROI DOUBLE AVEC ECRANS ARRI RE ET LATERAUX 178 mm 7 po NOTE RACCORD DU CONDUIT 1 RACCORD PAROI SIMPLE AVEC CRAN ARRI RE 521 mm 20 5 po AU COIN 2 RACCORD PAROI SIMPLE AVEC ECRANS ARRI RE ET LATERAUX 495 mm 195 po Hu PAR L AGENCE DE PROTECTION ENVIRONMENTALE SOUS 40 CFR 60 533 H AVEC NORMES EMISSIONS DE PARTICULES DE JUILLET 1990 EXIGENCES POUR L UTILISATION COMBUSTIBLE SOLIDE DE BOIS NE PAS SURCHAUFFER SI LE POELE OU LE RACCORD DE CHEMIN E MET UNE LUEUR C EST QUE VOUS SURCHAUFFEZ INSPECTER NETTOYER FREQUEMMENT LA CHEMIN E DANS CERTAINES CONDITIONS D UTILISATION LE DEPOT DE CREOSOTE PEUT SE FAIRE RAPIDEMENT NE PAS UTILISER DE GRILLE OL SURELEVER LE FEU BRULER LE BOIS DIRECTEMENT SUR L TRE RISQUE DE FUM E ET FUITE DE FLAMMES UTILISER il abe aah di AVEC LES PORTES DU FOYER DE RAMONAGE COMPLETEMENT FERMEES ATTENTION 7 CHAUD LORSQU IL FONCTIONNE NE PA
7. Install using the same four screws that held the cover plate in place the plate will not be reinstalled The blower should be plugged into a 110 VAC power source and is controlled by the rheostat knob 2 Coloque el soplador orientando el ventilador de manera tal que el aire fluya hacia arriba y entre el protector t rmico y la parte posterior de la pantalla cortafuegos de la estufa Instale usando los cuatro tornillos que sostenian la placa de la cubierta en su lugar la placa no ser reinstalada El soplador debe ser conectado a una fuente de alimentaci n de 110 VCA y deber ser controlado por medio de la perilla de un re stato 2 Placer le ventilateur en l orientant afin qu il souffle l air vers le haut entre l cran de chaleur et l arri re du pare feu du po le Installer l aide des quatre m mes vis qui maintenaient la plaque de protection en place la plaque ne sera pas repos e Le ventilateur doit tre branch dans une source de courant 110 volts CA il est command par le bouton du rh ostat ALWAYS FOLLOW ALL CODES AND OWNER S MANUALS iSIEMPRE SIGA TODOS LOS CODIGOS Y MANUALES DEL PROPIETARIO TOUJOURS SUIVRE TOUS LES CODES ET LES MODES D EMPLOI 12 POSITIONNEMENT ET INSTALLATION Le premier probleme que vous risquez de rencontrer est de rentrer votre po le chez vous tous nos po les sont bien construits ce qui les rend assez lourds Trois a quatre adultes peuvent normalement porter un po le mais
8. tipi gt Ceci permet une bonne circulation de l air ce qui est importante pour une bonne combustion Allumez le papier froiss a deux ou trois endroits diff rents REMARQUE Il est important de r chauffer l air dans le tuyau du po le pour amorcer le tirage Ouvrez fond le r gulateur d air du po le a bois et fermez sa porte en la laissant l g rement entrouverte pour permettre a lair de p n trer dans le foyer Ne laissez jamais la porte compl tement ouverte car il y a des risques d tincelles provenant du petit bois qui risqueraient de causer des blessures Au fur et mesure que le petit bois commence a br ler il peut falloir en ajouter pour alimenter le feu N AJOUTEZ PAS de papier apr s que le feu ait commenc br ler Une fois que le bois d allumage a commenc br ler commencez ajouter de petits morceaux de bois de chauffage sec REMARQUE Si vous ajoutez de gros morceaux au d but du feu cela l touffera Continuez d ajouter de petits morceaux de bois sec en laissant la porte l g rement entrouverte jusqu ce que chaque morceau soit enflamm N oubliez pas de toujours ouvrir la porte lentement quand vous rajoutez du bois dans le feu Une fois que le bois a commenc br ler et que la fum e a diminu fermez compl tement la porte du po le La r duction de la fum e est un bon indicateur que le tirage a commenc dans la chemin e et qu une bonne combustion est d sormais possible V
9. 25 26 FORMULAIRE D ENREGISTREMENT DE GARANTIE pour England s Stove Works Achet par nom Adresse Ville Etat Province Code Postal T l phone Adresse de courrier lectronique INFORMATIONS SUR LE CONCESSIONNAIRE Achet concessionnaire Adresse Ville tat Province Code Postal RENSEIGNEMENTS SUR L APPAREIL Assurez vous que vous faites r f rence a l autocollant l arri re de l appareil ou sur la bo te pour remplir la section ci dessous Mod le num ro Date d achat Prix d achat Num ro de s rie Date de fabrication Comment avez vous entendu parler de notre produit veuillez cocher une r ponse Bouche oreille D monstration de la remorque Internet Autre O avez vous re u des renseignements au sujet de notre produit veuillez cocher une r ponse Rens re us par t l phone Concessionnaire nom du concessionnaire Internet Autre REMARQUE IMPORTANT CES RENSEIGNEMENTS DOIVENT OBLIGATOIREMENT TRE ENREGISTR S POUR QUE LA PR SENTE GARANTIE SOIT VALABLE VEUILLEZ ENVOYER CES RENSEIGNEMENTS DANS LES TRENTE 30 JOURS SUIVANT LA DATE DE L ACHAT Envoyer England s Stove Works Inc Customer Service Department P O Box 206 Monroe VA 24574 E U Ou bien envoyez par t l copie au 434 929 4810 24 heures par jour Ou encore disponible d s maintenant Vous pouvez remplir votre garantie sur Internet Allez sur www englanderstoves com si vous pr f rez vous enreg
10. Air Supply B Atmospheric pressure affecting the draft from a chimney can be outside the home inside the home or both Outside the home a high pressure clear and cool day generally creates a better draft in the chimney than a low pressure overcast and damp day Inside the home household appliances such as forced air furnaces exhaust fans or clothes dryers compete for air often resulting in inadequate amounts of air available to fuel a fire and creating a condition known as negative pressure Extreme conditions of negative pressure can cause the combustion by products to be drawn from the chimney and into the house This condition is commonly known as down drafting C There are several factors that can affect the amount of air available in the home Increased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also make a home too airtight If you are in doubt as to whether or not there is sufficient air in your home for your stove refrain from using those appliances known to consume air when possible or open a door or a window to allow some air to enter the home ALWAYS PROVIDE A SOURCE OF FRESH AIR INTO THE ROOM WHERE THE UNIT IS INSTALLED FAILURE TO DO SO MAY RESULT IN AIR STARVATION OF OTHER FUEL BURNING APPLIANCES AND THE POSSIBLE DEVELOPMENT OF HAZARDOUS CONDITIONS D Environmental Conditions E High trees a low lying house location such as in a valley tall
11. Chimney Connector r Me See Note 3 See Note 3 And Floor Protection section Y Follow all venting system manufacturer s installation requirements AND their required clearances Exterior Wall Supported 18 0 Min pl M Lined with clay tile or other liner Single Wall R a Chimney lt Connector A TT 0 Min See Note 1056 Class A Chimney System Interior Ceiling Supported Single VVall Chimney Connector IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper installation Do not use makeshift methods or material which may compromise the installation England s will not be liable for consequential or indirect damages to property or persons resulting from the use of this product Call 800 245 6489 and or consult a professional installer if you have any questions Chimney Connector Systems and Clearances from Combustible Walls for Residential Heating Appliances Minimum 12 in 305 mm to combustibles of fl Air space 9 in 229 mm min Two ventilated air channels each 1 in 25 4 mm Construction of sheet steel supports Chimney section Chi Air space flush with inside Sheet steel onnector 2 in 51 mm Minimum chimney clearance to brick and combustibles 2 in 51 mm Min
12. allows wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be deposited within the system 3 BURN ONLY SEASONED WOOD Avoid burning wet or green wood Seasoned wood is wood that has been dried for at least one year 4 A small hot fire is preferable to a large smoldering one that can deposit creosote within the system 5 Establish a routine for fuel wood burner and firing technique Check daily for creosote build up until experience shows you how often you need to clean to be safe Keep in mind that the hotter the fire the less creosote is deposited and weekly cleanings may be necessary in milder weather although monthly cleanings may be enough in the coldest months Contact your local authority for information on how to handle a chimney fire and have a clearly understood plan to handle a chimney fire ASH DISPOSAL Regularly inspect the ash build up in your unit and remove as necessary Ashes can be removed from the unit by shoveling them off the firebrick This unit has an ash drawer plate see Illustration 4 that can be removed from the stove once removed the ashes can be raked through the opening and into the ash pan Caution The ash drawer plate can be extremely hot Never remove red hot ashes from the appliance allow ashes to cool before dropping into the ash pan Ashes should be placed in a metal container with an airtight lid The ashes should be placed on a noncombustible surface and
13. ce raccordement n est pas n cessaire bien qu il soit recommand pour les maisons herm tiquement ferm es Une trousse est offerte par England s Stove Works Inc elle est con ue pour raccorder cet appareil l air comburant ext rieur Pi ce n AC OAK3 14 FONCTIONNEMENT N utilisez pas de grille ni n levez le feu Allumez le feu de bois directement sur les briques A la premi re utilisation du po le les solvants de la peinture s vaporeront au fur et a mesure que le po le se lt fait gt BOIS Ce po le est con u pour ne br ler que du bois naturel On obtient en g n ral un meilleur rendement et moins d missions en brdlant du bois dur ayant bien s ch l air par rapport a du bois tendre ou du bois dur vert ou fraichement coup N utiliser que du bois sec Le bois vert en plus du fait qu il ne contient que 60 de la valeur calorifique du bois sec d pose de la cr osote a l int rieur du po le et de la chemin e Ceci pr sente un danger extr me de feu de chemin e Pour pouvoir tre appel lt sec gt le bois doit avoir s ch pendant un an Ind pendamment du fait que le bois soit vert ou sec il doit tre entrepos dans un endroit a r et l abri permettant un s chage correct pendant l ann e Le bois doit tre rang au del des d gagements recommand s par rapport aux produits combustibles NE PAS BRULER Bois trait ordures solvants d chets carton papier de couleur ou ch
14. de la Voir l illustration 1 pour les soufflante d gagement avec et sans crans thermiques lat raux Toutes les briques non rep r es ont une dimension de 1 po Illustration 4 IMPLANTATION DES BRIQUES 1 non rep r sur le sch ma brique de 9 x 4 x 1 4po Qt 25 3 brique 4 x 2 2 x 1 4 po Qt 1 2 brique 4 x 2 x 1 4 po Qt 1 4 plaque en m tal plaque de cendrier Qt 1 AC 16 Blower Installation Instruction Guide for Models with 30 in Model Number Guia de instrucciones de instalaci n del ventilador AC 16 Guide d installation du ventilateur AC 16 120 VOLTS 60Hz 0 75 AMPS 2900 RPM DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT 120 VOLTS 60Hz 0 75 AMPERE 2900 TR MIN DANGER RISQUE DE CHOC ELECTRIQUE DEBRANCHER L ALIMENTATION AVANT TOUTE INTERVENTION SUR L APPAREIL OPERATING INSTRUCTIONS This unit is set up for installation of an optional 2 speed blower motor The fan speed should be run on Low when the unit is operating at lower burn settings and set to High for high burns When routing the power cord be sure that the cord does not come into contact with any hot surface Install AC 16 Blower here using the 4 supplied mounting screws INSTRUCTIONS DE FONCTIONNEMENT Cet appareil est pr vu pour l installation d un moteur de soufflante en option 2 vitesses La vites
15. doit obligatoirement avoir refroidi et toutes les cendres avoir t nettoy es Enlevez les briques d branchez le conduit de fum e et mettre le po le sur l arri re Si vous remplacez des pieds ou un pi destal existants d tachez les pieds ou le pi destal Pour installer des pieds 1 Chaque pied rentre dans une fente chaque angle du dessous du po le 2 Un boulon de carrosserie de 3 8 po x 1 1 2 po ainsi qu un crou correspondant sont livr s avec chaque pied Mettez un pied dans une fente et alignez le trou du pied avec le trou de la fente Fixez les pieds un la fois l aide des boulons et crous fournis Bloquez solidement Pour installer un pi destal 1 Mettez les entretoises fournies entre les fentes du po le et l embase du pi destal une entretoise passe de chaque c t du pi destal Alignez les quatre trous du pi destal 2 de chaque c t avec les trous des entretoises et les fentes du po le Utilisez les quatre boulons de carrosserie de 3 8 po x 1 1 2 po et les crous fournis pour fixer le pi destal Pembase du po le Bloquez solidement Apr s avoir fix les pieds ou le pi destal remettez le po le debout rebranchez le conduit de fum e et remettez les briques conform ment au manuel 23 MOD LE 30 NC 50 SNC30 150 TNCSO APPAREIL HOMOLOGUE DE CHAUFFAGE AUTONOME A COMBUSTIBLE SOLIDE AUSSI UTILISABLE DANS LES MAISONS MOBILES MODELE SUR av SOCLE UNIQUE
16. existing door and pedestal or regular cast legs REPLACEMENT PARTS AC G30 DOOR GLASS KIT WITH GASKET AC GGK DOOR GLASS GASKET KIT gasket only no glass AC DGKNC DOOR GASKET KIT High Density fiberglass rope gasket AC SB 9 X 4 X 1 1 2 FIREBRICK see Brick Layout diagram AC SB2 4 X 2 X 1 1 2 FIREBRICK see Brick Layout diagram AC SB2 5 4 X 2 1 2 X 1 1 2 FIREBRICK see Brick Layout diagram AC 30BT1 FRONT BURNER TUBE AC 30BT2 SECOND BURNER TUBE from Front AC 30BT3 THIRD BURNER TUBE from Front AC 30BT4 REAR BURNER TUBE AC 30CFB CERAMIC FIBER BOARD 2 AC SH BRASS DOOR SPRING HANDLE AC SHN NICKEL DOOR SPRING HANDLE AC SH4 BRASS AIR CONTROL SPRING HANDLE AC SH4N NICKEL AIR CONTROL SPRING HANDLE AC 03 BRASS ASH PAN KNOB AC 03BN NICKEL ASH PAN KNOB AC MCSP HI TEMPERATURE CHARCOAL PAINT AC MBSP HI TEMPERATURE BLACK PAINT OPTIONS AC 30 ROOM AIR BLOWER AC 30SHSB SIDE HEAT SHIELD SYSTEM BLACk AC 116 BRASS ACCENT TRIM RING FOR DOOR P AND L MODELS ONLY AC 116BN NICKEL ACCENT TRIM RING FOR DOOR P AND L MODELS ONLY AC 115 BRASS LIP TRIM AC 115BN NICKEL LIP TRIM CA 12G GOLD PLATED LEG CA 30G GOLD PLATED DOOR AC 1677 FLUE COLLAR ADAPTER All parts can be ordered from your local dealer or from the factory at 1 800 516 3636 NOTE Parts and accessories are also available on our web site www englanderstoves com If you have any questions or problems contact the Customer Service Department
17. la chemise de la chemin e Au Canada l installation doit respecter la norme CAN CSA B365 lorsqu elle passe travers des mat riaux de construction combustibles APPLICATIONS D INSTALLATION suite Illustration 1b Conduits de fum e pr fabriqu s Depuis quelques ann es les conduits de fum e pr fabriqu s sont devenus tr s populaires parce qu ils sont tr s faciles a installer et quand l installation est r alis e correctement ils sont tr s s rs Il existe de nombreux conduits de fum e pr fabriqu s sur le march et il est important d en choisir un qui soit agr par U L ou ULC si le Canada B O C A ou 0 8 0 Tous ces syst mes sont construits avec les mat riaux corrects et sont conformes aux normes de s curit ad quates Votre concessionnaire local propose normalement une marque agr e de tuyaux pour conduit de fum e Il existe deux m thodes d installation tr s populaires pour ce type de chemin es La premi re la plus populaire et la moins ch re passe par le plafond et le toit C est le circuit le plus direct et celui qui cr e un bon tirage parce qu il n cessite le moins de tuyauterie C est moins cher car une conduite isol e est n cessaire seulement depuis le plafond jusqu au toit et au dessus une conduite murale simple de calibre 24 ou plus est utilis e depuis l unit jusqu au plafond si vous maintenez un espace de 16 pouces 16 0 d un mur combustible La seconde m thode d instal
18. le L 39 x H 52 5 mat riau combustible l existe de nombreux fabricants de panneaux muraux et de sol et vous devrez tre tr s prudent pour choisir la protection ad quate Le type de panneau que vous choisirez doit avoir t valu et Illustration 2 agr par PUL ou ULC si le Canada Apr s avoir examin la zone o vous pr voyez de placer votre po le et avoir d termin qu elle n cessite un panneau l tape suivante consiste a en s lectionner la taille ad quate La dimension du panneau n cessaire sera fonction du po le que vous aurez choisi La planche de protection agr e doit tre assez grande pour assurer un minimum de huit pouces 8 derri re l unit huit pouces 8 sur les deux c t s et seize pouces 16 l avant o se trouve la porte La protection doit avoir une valeur R de 1 5 unit s anglaises ou quivalente Voir Installation sur un plancher combustible Ce fourneau requiert une protection de plancher de 39 0 x 52 5 au minimum Installation sur un sol en b ton Un appareil mont sur un sol en b ton ne n cessite pas de protection du sol Ni moquette ni aucun autre mat riau combustible ne doit couvrir le protecteur de sol Si la surface combustible est appliqu e sur un sol en b ton un d gagement est obligatoire sur une surface quivalente celle r serv e au protecteur de sol C t porte Installation sur un sol combustible Si l appareil
19. nous pr conisons quand m me l utilisation d un chariot Ne jamais essayer de manipuler seul e un produit de chauffage La porte et les briques peuvent tre retir es temporairement pour all ger le po le voir le plan des briques Apr s que le po le soit a sa place installez les poign es en ressort et attachez l quipement en option s il y en a Tuyau de raccordement la chemin e Le tuyau noir doit obligatoirement avoir un diam tre de six pouces 6 po et tre en acier d paisseur au moins n 24 N utilisez pas de tuyau en aluminium ou en acier galvanis qui ne supporterait pas les temp ratures tr s lev es produites par le po le De m me n utilisez pas un tuyau de raccordement paroi simple comme chemin e vous devez obligatoirement raccorder votre po le une chemin e comparable celles d crites ci dessus dans ce manuel L extr mit sertie de votre tuyau doit tre ins r e dans la buse et de ce fait tout le tuyau sera invers Si vous utilisez cette m thode la cr osote descendra le long de l int rieur de votre tuyau et ne sortira pas par les jointures sur le po le Comme mesure de s curit tous les joints doivent tre fix s ensemble par au moins trois 3 vis en t le Pour le bon fonctionnement le raccord de chemin e doit tre aussi court que possible et ne jamais d passer une distance horizontale de six pouces 6 po Les parcours horizontaux du raccord de chemin e doivent avoir une p
20. vis t le Faites de m me chaque jointure suppl mentaire pour rigidifier l installation 9 Maintenez le diam tre de conduit de fum e requis sur toute la longueur de l installation 10 Si vous raccordez le po le a un conduit de fum e maconn ancien assurez vous qu il a t inspect et ne pr sente ni fissure et est en bon tat g n ral Il pourra s av rer n cessaire de recalibrer le conduit avec un doublage en inox 11 On recommande de ne pas utiliser plus de deux coudes 90 dans un conduit de tuyau de po le Un nombre de coudes 90 sup rieur deux risque de r duire le tirage voire de causer des fuites de fum e 12 Une installation de cette sorte ne n cessite pas de clef de tuyau Enlevez la plaque de registre de la chemin e ou bloquez la en position OUVERTE 13 La longueur totale des ensembles de conduits de fum e paroi simple ne doit pas d passer 10 pieds 13 CHEMINEE REPORTEZ VOUS AUX INSTRUCTIONS DU FABRICANT DE LA CHEMINEE ET DU RACCORD DE CHEMINEE Avertissement Installez VENT AU d gagements sp cifi s PAR LA VENT DU FABRICANT PRENEZ CONTACT AVEC L AUTORIT DE CONSTRUCTION LOCALE POUR LES METHODES 3 pi mini partir D INSTALLATION AGREEES de la p n tration 1 Cet appareil n cessite une chemin e ma onn e ou dans le toit pr fabriqu e enregistr e en fonction de UL UL103HT ULC S629 Canada de dimensions correctes Si une chemin e est utilis e il est recomman
21. 00 516 3636 uniquement pour des pieces d tach es pour les questions techniques appelez le 800 245 6489 Suivez les tapes ci dessous pour remplacer le joint de la porte 1 Assurez vous que l appareil n est pas en fonctionnement et qu il a compl tement refroidi 2 Enlevez le vieux joint de la porte et nettoyez le logement du joint 3 Appliquez une couche mince de colle joints haute temp rature dans le fond du logement 4 En commen ant du c t de la charni re de la porte enfoncez le joint dans son logement tout autour de la porte coupez le la bonne longueur et mettez les deux extr mit s bout bout 5 Fermez la porte et attendez trois quatre heures que la colle s che avant de rallumer le feu PANNEAU DE FIBRES SOIN amp ENTRETIEN CE POELE A BOIS UTILISE UNE TECHNOLOGIE NOUVELLE QUI FAIT APPEL UN PANNEAU EN FIBRES DE C RAMIQUES SITU DANS LE FOYER O IL REPOSE SUR QUATRE TUBES EN ACIER INOXYDABLE NE PAS RETIRER CE PANNEAU EN FIBRE DE C RAMIQUE C EST UN COMPOSANT N CESSAIRE DU FOYER VEUILLEZ AUSSI NOTER QUE IL SE PEUT QUE LE PANNEAU DE FIBRES EN CERAMIQUE TOMBE PENDANT LE TRANSPORT INITIAL ASSUREZ VOUS QU IL EST A PLAT SUR LES TUBES EN INOX ET QU IL EST POUSSE A FOND L ARRI RE DU POELE SANS ESPACE ENTRE LE PANNEAU ARRIERE ET LA PAROI ARRIERE Appelez le 800 245 6489 si vous avez des questions ENTRETIEN Cet appareil est quip d un d flecteur de plafond en panneau d
22. AO 8 0cON L 0 PUP 0 ONS OS ON O Soqny UMA 99 S SSAJUTEIS JO Ju ur op q ple 1808 2V M 9 Du SI HO MATA d 15 qn puz 1808 2V OLE GOT s oH SI 9 ANA SI ql he qn J9UING U014 L190 9V SVE I NE SF s loH 181 Z gt N SIE 1 92 0 HUN 10 _ p S 1000 1404 17 CREOSOTE When wood is burned slowly it produces tar and other organic vapors These combine with moisture to form creosote Creosote vapors condense in the relatively cool chimney flue of a slow burning fire as a result creosote residue accumulates on the lining of the flue If ignited this creosote makes an extremely hot fire The chimney should be inspected on a regular basis during the heating season to determine if a creosote build up has accumulated If it has the creosote should be removed to reduce the risk of chimney fire WARNING THINGS TO REMEMBER IN CASE OF A CHIMNEY FIRE 1 CLOSE DRAFT CONTROL 2 CALL THE FIRE DEPARTMENT WAYS TO PREVENT AND KEEP UNIT FREE OF CREOSOTE 1 Burn with the air control fully open for several minutes at numerous intervals throughout each day during the heating season being careful not to over fire the unit This should remove the slight film of creosote that accumulates during low burn periods 2 Burn the stove with the draft control fully open for approximately 20 30 minutes every time you apply fresh wood This
23. Check with authorities having jurisdiction in your area with any questions 7 All pipe sections must be connected with the male crimped end toward the stove 8 Fasten the stove pipe to the flue collar by the use of three sheet metal screws Do the same at each additional joint to make the entire installation rigid 9 Maintain the required diameter flue for the entire installation 10 If you are connecting the stove to an old masonry flue be sure to have it inspected for cracks and general condition Resizing with a stainless steel liner may be required 11 It is recommended that no more than two 90 degree bends be used in the stovepipe installation More than two 90 degree bends may decrease the amount of draw and possibly cause smoke spillage 12 A damper is not required in this installation Remove the damper plate in the chimney or secure it in the OPEN position 13 Single wall flue pipe assemblies must not exceed 10 feet in overall length 12 CHIMNEY REFER TO CHIMNEY AND CHIMNEY CONNECTOR MANUFACTURER S INSTRUCTIONS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF INSTALLATION 1 This appliance requires a masonry or pre 3 ft min from manufactured chimney listed to UL103HT roof penetration sized correctly ULC S629 if Canada If a masonry chimney is used it is advisable to have your chimney inspected for cracks and check th
24. E CETTE DIRECTIVE PEUT PRIVER LES AUTRES APPAREILS DE COMBUSTION ET CR ER DES SITUATIONS SUSCEPTIBLES D TRE DANGEREUSES D Conditions environnementales E De grands arbres une maison en contrebas dans une vall e par exemple des immeubles ou des constructions lev s autour de chez vous voire un temps venteux peuvent causer un mauvais tirage ou une rupture de tirage F Chemin e froide G Evitez une chemin e froide en faisant br ler un feu chaud pendant les quinze a quarante premi res minutes apr s avoir allum le feu en veillant a ne pas le laisser s emballer Si une partie quelconque de la chemin e ou des parties du po le se mettent briller le po le est emball Quand c est possible installez un thermom tre sur la chemin e afin de pouvoir voir les baisses de la temp rature H Installation et entretien de la chemin e I Evitez d utilisez trop de coudes ou de longues parties horizontales En cas de doute prenez contact avec un sp cialiste en chemin es et ou un fabricant de chemin es pour obtenir de l aide Nettoyez votre chemin e son ses chapeau x et sp cialement le pare tincelles r guli rement afin d viter les accumulations de cr osote celles ci peuvent r duire sensiblement le tirage dans la chemin e voire causer un feu de chemin e 10 Est ce que je dois ouvrir le r gulateur d air a fond quand j teins le po le Quand vous teignez le po le ouvrez le r gulateur d air
25. FUEL BURNING APPLIANCES AND THE POSSIBLE DEVELOPMENT OF HAZARDOUS CONDITIONS THIS HEATER IS EXTREMELY HOT WHILE IN OPERATION SERIOUS BURNS CAN RESULT FROM CONTACT CAUTION SHOULD BE OBSERVED ESPECIALLY WHEN CHILDREN ARE PRESENT FLUE SYSTEM 1 Existing Flue System If you have chosen a freestanding unit this stove is designed to connect to an existing flue system such as masonry or a pre manufactured Class A flue system If you have a masonry flue system the inner liner should be inspected carefully for cracks if there is no liner in your chimney we recommend you install a steel liner or have one installed If you have an existing pre manufactured system the inner liner should be inspected for warping or buckling Either type chimney system should be thoroughly cleaned before installing your new stove We strongly recommend you have a qualified chimney sweep clean and inspect your entire system as the sweep can spot problems you might overlook The sweep in most cases can make any necessary repairs or recommend a qualified person to do so It is not permissible to connect this unit to a chimney that is servicing another unit 2 Flue Size The proper flue size is determined by measuring the inside diameter of the flue collar on the unit This stove is equipped with a six inch 6 TOP EXHAUST FLUE COLLAR Therefore the connector pipe should be six inches 6 and never less in diameter than the collar on the stove Your unit may r
26. Hookup You can use an outside air hookup with this unit We highly recommend it for homes built since the more air tight construction standards went into effect This involves connecting a metal pipe usually three inches 3 in diameter check your stove and the pipe can be flex or rigid from the air inlet pipe located on the bottom rear of the stove through your floor or wall The outside end of this pipe should be covered in some manner i e with a screen to keep it clear of foreign matter Be sure to keep it above the snowdrift line and clear of leaves and other debris It is necessary to use this hookup if installing in a mobile home or double wide See Outside Air Connection section of manual A kit is available from England s Stove Works Inc designed for connecting this unit to outside combustion air Part No AC OAK3 WHY THE CORRECT FLUE SIZE IS IMPORTANT 6 Draft is the force that moves air from the appliance up through the chimney The amount of draft in your chimney depends on the length of the chimney local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the appliance An uncontrolled burn or a glowing red part or chimney connector can indicate excessive draft Inadequate draft may cause back puffing into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance and chimney connector joints
27. INSTALLATION amp OPERATION MANUAL MODEL NUMBERS 30 NCP 50 SNC30P 50 TNC30P 30 NCL 50 SNC30L 50 TNC30L 30 NCG 50 SNC30G 50 TNC30G Thank you for purchasing this product from a fine line of heating equipment We wish you many years of safe heating pleasure with your new heating appliance Save These Instructions IMPORTANT IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER CONTACT CUSTOMER SERVICE 1 800 245 6489 Questions Need Parts or Options www englanderstoves com Please Note the Following Precautionary Statements England s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product including this unit Follow all manufacturers instructions when using smoke or Carbon Monoxide detectors CAUTION This stove must be installed in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 and must comply with local building and fire codes Failure to follow these instructions could result in property damage bodily injury or even death Keep children furniture fixtures and all combustibles away from any heating appliance NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE PEDESTAL MODEL ONLY NOT FOR LEG MODELS DO NOT INSTALL IN A SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED CAUTION This unit must be installed in acco
28. MENT WIN 12796 TESTE A UL 1482 ULC S627 PREVENIR LES INCENDIES INSTALLER ET UTILISER UNIQUEMENT SELON LE MANUEL DU PROPRI TAIRE JOINT CET APPAREIL COMMUNIQUER AVEC LE SERVICE LOCAL DE LA CONSTRUCTION O LE SERVICE D INCENDIE RELATIVEMENT AUX RESTRICTIONS ET AUX INSPECTIONS DE L INSTALLATION DANS VOTRE QUARTIER EXIGENCES D INSTALLATION NE PAS RACCORDER CET APPAREIL A UN CONDUIT DE CHEMIN E QUI SERT A UN AUTRE APPAREIL UTILISER UNE CHEMINEE EN MACONNERIE DE TYPE RESIDENTIEL OU FABRIQUEE EN USINE ET CLASSEE TYPE HT UTILISER UN RACCORD DE CHEMIN E NOIR OU BLEU CALIBRE 24 MSG OU OU A DOUBLE PAROI HOMCLOGUE CONSULTER LES CODES LOCAUX ET LES DIRECTIVES DU FABRICANT RELATIVEMENT AUX PRECAUTIONS A PRENDRE POUR PASSER UNE CHEMIN E A TRAVERS UN MUR OU UN PLAFOND COMBUSTIBLE POSER SUR UNE PROTECTION NON COMBUSTIBLE DE PLANCHER D UNE VALEUR R MINIMALE DE 1 5 QUI SE PROLONGE 406 mm 16 po VERS L AVANT ET 203 min 8 po DE CHAQUE COTEDE L OUVERTURE POUR LE COMBUSTIBLE L FAUT INSTALLER LES PATTES APRES L APPAREIL NE PAS ENCOMBRER L ESPACE SOUS L APPAREIL DE CHAUFFAGE SUIVRE LES ESPACEMENTS MINIMAUX SUIVANTS AUX COMBUSTIBLES LORS DE L UTILISATION D UN RACCORD DE CHEMIN E PAROI SIMPLE CONSULTER LE MANUEL DU PROPRI TAIRE POUR D AUTRE INFORMATION iH Fr s du sol mint pox 4B po SURFACES NON PROT G ES SURFACES PROTEGEES NFPA 211 C T A ARRI RE B COIN D C T A ARRI RE B COIN D
29. Ni conduits de fum e ni tuyaux ne sont fournis avec l appareil Conduit de fum e ma onne Au cas o vous pr voiriez d installer un circuit ou d en faire installer un vous avez plusieurs solutions Au milieu et la fin des ann es soixante dix les conduits de fum e ma onn s taient tr s populaires et aujourd hui ce type de circuit reste satisfaisant Si vous envisagez un circuit ma onn consultez les responsables de la construction locaux pour conna tre les proc dures correctes par rapport ce type de chemin e Nous vous recommandons de consulter un entrepreneur cautionn et agr et de lui faire construire votre conduit de fum e La plupart des chemin es ma onn es sont plac s contre un mur ext rieur et d passent la hauteur de la maison Le manchon d emboftement est ensuite ins r au travers du mur pour r aliser le raccordement entre le tuyau du po le et le conduit de chemin e verticale Ne percer le mur qu avec extr mement de pr cautions vous devez obligatoirement maintenir un d gagement correct entre la gaine de raccordement et les ventuels mat riaux combustibles dans le mur Nous pr conisons galement d installer une trappe de nettoyage qui sera situ e au moins deux pieds 2 pi en dessous du manchon d embo tement pour faciliter le ramonage de votre circuit L tanch it de cette trappe doit tre aussi parfaite que possible C est la responsabilit du consommateur de s assurer que le cir
30. S TOUCHER TENIR L CART LES ENFANTS LES V TEMENTS ET LE MOBILIER LE CONTACT PEUT CAUSER DES BR LURES DE LA PEAU VOIR LA PLAQUE SIGNAL TIQUE ET LES DIRECTIVES FABRIQU PAR ENGLAND S STOVE WORKS NC MONROE VA 24574 7 24 Gardez ces renseignements port e de la main si vous t l phonez l usine ou a votre concessionnaire propos de ce produit conserver pour vos fichiers Mod le num ro Date d achat Date de fabrication Num ro de s rie GARANTIE LIMITEE DE 5 ANS A PARTIR DE LA DATE D ACHAT EN FAVEUR DU PROPRIETAIRE ORIGINAL Le fabricant tend les garanties ci dessous P riode de cinq ans 1 Les l ments en acier au carbone et les soudures dans le foyer sont couverts pendant 5 ans contre les fissures 2 La porte le fermoir et les charni res en fonte sont couverts pendant 5 ans contre les f lures P riode de un an 3 Les composant comme les tubes et les pattes de fixations de briques en inox par exemple sont couverts pendant 1 an contre les fissures les casses et la s paration des soudures 4 La cloison en panneau de fibres c ramiques les composants lectriques les accessoires le verre et la surface peinte sont couverts pendant 1 an compter de la date de l achat Conditions et exclusions Les d g ts caus s par un emballement annulent votre garantie La pr sente garantie est inapplicable aux d g ts provenant d accidents de mauvaise manutention de mauvaise in
31. SHN POIGNEE A RESSORT DE PORTE NICKEL AC SH4 POIGNEE A RESSORT LAITON DU REGULATEUR D AIR AC SH4N POIGNEE A RESSORT NICKEL DU REGULATEUR D AIR AC 03 POIGNEE DE BAC A CENDRES LAITON AC 03BN POIGNEE DE BAC A CENDRES NICKEL AC MCSP PEINTURE CHARBON DE BOIS HAUTE TEMPERATURE AC MBSP PEINTURE NOIRE HAUTE TEMPERATURE OPTIONS AC 30 SOUFFLANTE D AIR POUR LA PIECE AC 30SHSB SYSTEME D ECRANS THERMIQUES LATERAUX NOIRS AC 116 BAGUE DE GARNITURE LAITON POUR PORTE MODELES P ET L UNIQUEMENT AC 116BN BAGUE DE GARNITURE NICKEL POUR PORTE MODELES P ET L UNIQUEMENT AC 115 GARNITURE DE LEVRE LAITON AC 115BN GARNITURE DE LEVRE NICKEL CA 12G PIED DORE CA 30G PORTE DORE AC 1677 ADAPTATEUR POUR BUSE Toutes les pieces peuvent tre command es chez votre concessionnaire ou aupr s de lusine au 1 800 516 3636 REMARQUE Les pi ces et les accessoires sont galement disponible sur notre site Web www englanderstoves com Si vous avez la moindre question ou probl me prenez contact avec le service client le SERVICE CLIENT LE P 0 BOX 206 MONROE VA 24574 Etats Unis Questions techniques service client le 800 245 6489 T l copie 434 929 4810 Commande de pi ces uniquement 800 516 3636 Adresse lectronique service englanderstoves com 22 Montage d un pied Options et d tail de l embase INSTRUCTIONS D INSTALLATION POUR LES PIEDS OU LE PIEDESTAL Le po le
32. T OLE I I aqny SHOLI az np sno n sa T 001 008 SE 602 4622 pon gt olk oh gt 0 2 f GE oy SIE 006 0 of of ajgod np aj 10d 9399 yuvay 141802 e aqn 13T np snon s T SiT e yuoj aqn a np 5 SAT SLE GBT SHOLL 18 CREOSOTE Quand du bois br le lentement il produit du goudron et d autres vapeurs organiques Ceux ci se combinent avec l humidit pour former de la cr osote Les vapeurs de cr osote se condensent dans le conduit de fum e d une chemin e feu lent o il fait relativement froid de ce fait les r sidus de cr osote s accumulent sur la gaine du conduit de fum e Si elle s enflamme cette cr osote cause un feu extr mement chaud La chemin e doit tre inspect e r guli rement pendant la saison de chauffage pour v rifier l absence d un d p t de cr osote S il y en a la cr osote doit tre ramon e pour r duire le risque d un feu de chemin e ATTENTION DANGER RAPPELEZ VOUS CES ACTIONS EN CAS DE FEU DE CHEMIN E 1 FERMEZ LA COMMANDE DE TIRAGE 2 APPELEZ LES POMPIERS MOYENS D EMPECHER LA FORMATION DE CREOSOTE 1 Laissez le feu br ler avec le r gulateur d air ouvert fond pendant plusieurs minutes a de nombreuses reprises chaque jour pendant la saison de chauffage en veillant ne pas laisser le feu s emballer Cett
33. TOUJOURS UNE SOURCE D AIR FRAIS DANS LA PIECE OU L APPAREIL EST INSTALLE A DEFAUT IL PEUT EN RESULTER UN MANQUE D AIR AUX AUTRES APPAREILS QUI BRULENT UN COMBUSTIBLE ET L APPARITION POSSIBLE DE CONDITIONS DANGEREUSES CET APPAREIL DE CHAUFFAGE EST EXTREMEMENT CHAUD QUAND IL EST EN FONCTIONNE MENT DES BRULURES GRAVES RISQUENT D ETRE CAUSEES A SON CONTACT IL IMPORTE DE FAIRE ATTENTION TOUT PARTICULIEREMENT QUAND DES ENFANTS SONT PRESENTS CONDUIT DE FUMEE 1 Conduit de fum e existant Si vous avez choisi un appareil ind pendant ce po le est con u pour se raccorder a un conduit de fum e existant par exemple un maconn ou pr fabriqu de classe A Si votre conduit de fum e est ma onne le rev tement int rieur doit tre inspect soigneusement pour v rifier l absence de fissures si votre chemin e n a pas de rev tement int rieur nous pr conisons l installation d une gaine en inox par vous ou par un installateur S il existe un conduit pr fabriqu le rev tement int rieur devra tre inspect pour v rifier l absence de d formation ou de flambage Quel que soit le type de chemin e elle doit tre soigneusement ramon e avant l installation de votre nouveau po le Nous pr conisons fortement de faire ramoner et inspecter toute votre tuyauterie par un ramoneur qualifi celui ci pouvant rep rer d ventuels probl mes qui vous chapperaient Le ramoneur dans la plupart des cas pourra faire les r parati
34. Today s solid fuel appliances are much more efficient than in the past The units are designed to give you controlled combustion as well as maximum heat transfer using less fuel to do so The design of your new appliance is such that the exhaust smoke is now at lower temperatures than in the past therefore requiring proper chimney size to give adequate draft If your chimney is too large the heater will have a difficult time raising the temperature of the flue enough to provide adequate draft which can cause a smoke back poor burn or both Should you experience such problems call in a local chimney expert With the door closed the rate of burning is regulated by the amount of air allowed to enter the unit through the air control With experience you will be able to set the control for heat and burning time desired Attempts to achieve higher output rates that exceed heater design specifications can result in permanent damage to the heater The recommended wood load is level with the top of the firebricks Overloading may prevent sufficient air entering the heater to properly fuel the fire Do not tamper with the combustion air control beyond the normal adjustment capacity Operate this heater only with the door closed DO NOT OVERFIRE If the heater or chimney connector glows you are overfiring ALWAYS PROVIDE A SOURCE OF FRESH AIR INTO THE ROOM WHERE THE UNIT IS INSTALLED FAILURE TO DO SO MAY RESULT IN AIR STARVATION OF OTHER
35. VE THIS CERAMIC FIBER BOARD IT IS ANECESSARY COMPONENT OF THE FIREBOX ALSO PLEASE NOTE THE CERAMIC FIBER BOARD MAY BECOME LOOSE DURING INITIAL SHIPPING BE SURE IT IS LYING FLAT ON TOP OF THE STAINLESS STEEL TUBES AND PUSHED ALL THE WAY TO THE BACK OF THE UNIT WITH NO GAPS BETWEEN IT AND THE BACK WALL Call 800 245 6489 if questions MAINTENANCE This unit is equipped with a ceramic Fiber Board ceiling baffle two pieces After extensive use the board should be removed and cleaned The following steps should be followed for cleaning or replacement 1 2 Ensure the appliance is not in operation and is completely cooled down There is one screw in each stainless steel tube holder located in the fire box ceiling Remove the screws from the front and middle tube holders Shift each loose tube to the right so that one end comes completely out of the socket Drop the end down and pull it out by pulling it back to the left Drop the first board down and push the left corner to the top left Bring the right corner down to the bottom right of your door opening and pull the right side out first Repeat for the second board piece Vacuum the boards off and blow the carbon out of the tubes if there is any build up Re install the boards and tubes reversing the same method they were removed 16 aqny J9UING s q 012 ZEG AIVA STIH S fOH h ur Hun 10 4e8y ST POUL
36. actured Flue System In the past few years pre manufactured flue systems have become very popular because this type system is easily installed and when done correctly is very safe There are many pre manufactured flue systems on the market and when making your choice it should be U L U L C if Canada B O C A or 1 C B O approved Any of these systems are constructed of the proper materials and meet the proper safety standards Your local dealer normally handles an approved brand of flue pipe There are two very popular methods for installation of this type system The first most popular and least expensive is through the ceiling and out the roof This is the most direct route and creates a good draw because it requires less pipe It is less expensive because insulated pipe is needed only from the ceiling to the roof and above single wall 24 gauge or thicker pipe is used from the unit to the ceiling if you maintain sixteen inches 16 0 of clearance from a combustible wall The second method for installing a pre manufactured system is to exit through the wall and run the system vertically up the outside of the structure This method is more expensive because more insulated pipe is required you must use insulated pipe through the wall and up the outside of the structure In either installation proper clearances to combustibles should be maintained Your flue pipe manufacturer furnishes a wall thimble or ceiling support box and when installe
37. age de chemin e peut provenir de l ext rieur du domicile de l int rieur de celui ci ou la fois de l int rieur et de l ext rieur A l ext rieur du domicile une haute pression temps d gag et frais suscite un meilleur tirage dans la chemin e qu une basse pression temps couvert et humide A l int rieur du domicile des appareils m nagers comme des fournaises air puls des ventilateurs aspirants ou des s cheuses peuvent expulser de l air n cessaire pour alimenter un feu et cr er une condition connue sous le nom de pression n gative Des conditions extr mes de pression n gative peuvent causer l infiltration dans la maison de sous produits de combustion provenant de la chemin e Cette condition est commun ment appel e courant ascendant C Plusieurs facteurs peuvent avoir une incidence sur la quantit d air disponible dans le domicile Une isolation plus importante des fen tres de vinyle un calfeutrage suppl mentaire en plusieurs endroits et des joints d tanch it des portes peuvent emprisonner la chaleur mais aussi rendre le domicile trop tanche Si vous n tes pas certain si la quantit d air dans le domicile est suffisante ou pas vitez d utiliser ces appareils connus pour consommer de l air dans la mesure du possible ou ouvrez une porte ou une fen tre pour permettre a l air d entrer dans le domicile FOURNISSEZ TOUJOURS UN APPORT EN AIR FRAIS DANS LA PIECE OU L UNITE EST INSTALLEE LE NON RESPECT D
38. ans tous les domaines d une installation correcte et sure N utilisez pas de compromis temporaires ou improvis s pendant l installation 10 11 12 13 14 15 AVANT L INSTALLATION DE VOTRE POELE CHAUD PENDANT LE FONCTIONNEMENT TENEZ LES ENFANTS LES VETEMENTS ET LES MEUBLES A L ECART LE CONTACT RISQUE DE CAUSER DES BRULURES A LA PEAU NE BRULEZ PAS D ORDURES NI DE LIQUIDES INFLAMMABLES V rifiez le respect des codes locaux aupr s du service de l inspecteur en b timent au cas o un permis serait obligatoire Cet appareil n cessite une chemin e magonn e ou pr fabriqu e enregistr e en fonction de ULC S629 au Canada et UL103HT aux E U de dimensions correctes Un conduit de fum e de 6 po est n cessaire pour obtenir les performances correctes Toujours raccorder ce po le a une chemin e et ne JAMAIS vacuer la fum e dans une autre pi ce ni l int rieur d un batiment NE PAS raccorder a un conduit auquel un autre appareil est raccord comme par exemple un appareil de chauffage NE PAS raccorder ce po le a un conduit de fum e servant a un autre appareil NE PAS UTILISER DE PRODUITS CHIMIQUES NI DE LIQUIDES POUR ALLUMER LE FEU Le tuyau de raccordement et la chemin e doivent tre inspect s p riodiquement et ramon s le cas ch ant N oubliez pas les distances de d gagement quand vous mettez des meubles ou d autres objets dans la zone Prenez contact avec le service d in
39. arbon REGLAGE DES COMMANDES pour la appelez vous de bien aerer Laissez le po le se lt r der gt avant de commande darrivee dair Ane A Taux de combustion R glage de l entr e d air faire du feu pendant de longues dur es a Bas Compl tement ferm haute temp rature Des taches mates sur la surface peinte sont normales Haut Des taches brillantes sur la surface peinte avant de faire du feu sont normales Appelez le service client le au 800 245 6489 si vous avez la moindre question PR PARATION D UN FEU 1 Ouvrez la commande d arriv e d air fond REMARQUE La commande se trouve sous le cendrier Elle s ouvre en la tirant vers l ext rieur 2 Mettez un peu de papier froiss dans le po le 3 Couvrez le papier avec une quantit g n reuse de bois d allumage en forme de tipi ainsi que quelques morceaux de bois 4 Allumez ce combustible et fermez la porte presque compl tement laissez la entrouverte 5 Ajoutez des morceaux de bois plus gros au fur et mesure que le feu progresse en veillant ne pas surcharger le po le Ne remplissez pas le foyer au dessus de la partie en briques r fractaires Une couche de charbon de 1 2 po en th orie doit tre tablie pour obtenir une performance optimale 6 Cet appareil est con u pour fonctionner avec le meilleur rendement quand l air peut circuler vers toutes les zones du foyer Un bon moyen dy parvenir est de fair
40. are many variables that can affect your rate of success when starting a fire and experience will teach you how to deal with the variables This section of the manual will cover some of the variables that can affect a fire and time and patience will contribute to your ability to start a good fire consistently Why can t get the fire lit Damp or wet wood and poor draft are the main reasons for poor results when starting a fire Remember to always use dry seasoned wood for your fire Even wood that has been dried Seasoned for a long period of time will be difficult to light if it has gotten wet Why is there always a large quantity of thick black smoke in the firebox A large quantity of thick black smoke in the firebox is a possible indication that you have poor draft 19 7 Is it normal for soot to cover the glass at the beginning of a fire This stove has been built with an air wash system that will help keep the glass clear when the firebox has reached a good operating temperature and also has a good draft Cold firebox temperature and poor draft cause soot to form on the glass Once the firebox temperature and the draft increase the soot should burn off 8 What is draft Draft is the ability of the chimney to exhaust draw by products produced during the normal process of combustion 9 What can cause a poor draft There are several common factors that can contribute to poor draft A Atmospheric Pressure and
41. areil est telle que la fum e gt qui en sort est maintenant une temp rature plus basse que ceux d autrefois par cons quent il n cessite un dimensionnement correct de la chemin e pour avoir un tirage ad quat Si votre chemin e est trop grande l appareil de chauffage aura des difficult s a faire atteindre au conduit de fum e une temp rature suffisante pour permettre un tirage ad quat ce qui causera retour de fum e mauvaise combustion ou les deux En cas d apparition de ce genre de probl me appelez un expert local en chemin es Quand la porte est ferm e le taux de combustion d pend de la quantit d air qui p n tre dans l appareil par le r gulateur d air Avec l exp rience vous pourrez r gler le r gler en fonction de la chaleur et de la dur e de combustion d sir s Les tentatives d obtenir des taux de combustions sup rieurs aux normes de conception de l appareil de chauffage risquent de causer des dommages permanents a celui ci La charge de bois recommand e est au niveau du haut des briques r fractaires Une surcharge risque d emp cher suffisamment d air d entrer dans le po le pour alimenter le feu correctement Ne manipulez pas le r gulateur d air de combustion au del des r glages normaux Ne faites fonctionner cet appareil de chauffage qu avec la porte ferm e NE LAISSEZ PAS LE POELE S EMBALLER Si le po le ou le raccord de chemin e brille le po le est emball FOURNISSEZ
42. auteur de la neige et d gag e des feuilles et autres d bris II est n cessaire de r aliser ce branchement si Pinstallation est r alis e dans une maison mobile simple ou double voir la section Raccordement l air ext rieur dans ce manuel Une trousse est offerte par England s Stove Works Inc elle est con ue pour raccorder cet appareil l air comburant ext rieur Pi ce n AC OAK3 POURQUOI LA TAILLE CORRECTE DU CONDUIT DE FUM E EST IMPORTANTE 6 po Le lt tirage gt est la force qui fait monter dans la chemin e l air provenant de l appareil de chauffage La quantit de tirage dans votre chemin e d pend de la longueur de la chemin e de la g ographie locale des obstructions proches et d autres facteurs Un tirage excessif risque de causer une temp rature trop lev e dans le po le Une combustion incontr l e ou la couleur rouge vif d une partie du po le ou d un raccord peuvent indiquer un tirage excessif Un tirage inad quat risque de causer des retours de fum e dans la pi ce ainsi que l obturation de la chemin e et ou des fuites de fum e dans la pi ce par les jointures de l appareil et des raccords avec la chemin e Les appareils de chauffage a combustible solide actuels ont un bien meilleur rendement qu autrefois 15 sont con us pour donner une combustion contr l e ainsi qu un transfert de chaleur maximal en utilisant moins de combustible La conception de votre nouvel app
43. aux Connecteur de chemin e murale simple Voir la note 3 Et la section Protection du sol Suivez toutes les exigences d installation du fabricant du syst me de ventilation et de leurs autorisations n cessaires Soutenue par un mur ext rieur Gain e de carreaux de terre ou autre gaine Connecteur de chemin e murale simple Circuit de chemin e de classe A Soutenue par un plafond int rieur Connecteur de chemin e murale simple MAUVAISE INSTALLATION Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnement du po le d une mauvaise installation N utilisez pas de m thodes ou de mat riaux improvis es qui pourraient compromettre l installation England s ne sera pas responsable des dommages indirects aux biens ou aux personnes qui r sulteraient de l utilisation de ce produit Appelez le 800 245 6489 et ou consultez un installateur professionnel si vous avez la moindre question Raccords de chemin e et degagements par rapport aux murs combustibles pour les appareils de chauffage r sidentiels D zazemert minimum de la chemin e par mne briques et ameomat rimo combustibles 2 po 51 mm D gagemert minimom 12 po 305mm 8 pa de briques E Raccord de da la chemin e oissem en argile Chemin e ma orm e consmumes 211 D gagemert minimum de la chemin e entre ma ormerie et supports entole d acier bri
44. buildings or structures surrounding your house and even windy conditions can cause poor draft or down drafting F Cold Chimney Temperature G Avoid cold chimney temperatures by burning a hot fire for the first fifteen to forty minutes after building a fire being careful not to over fire If any part of the chimney or parts of the stove start to glow you are over firing the stove Where possible install a temperature gauge on the chimney so temperature drops can be seen H Chimney Installation and Maintenance 1 Avoid using too many elbows or long horizontal runs If in doubt contact a chimney expert and or chimney manufacturer for help Clean your chimney rain cap s and especially the spark arrester regularly in order to prevent creosote build up which can significantly reduce chimney draw and possibly create a chimney fire 10 Should close or open the air control fully when shutting down the stove When shutting down the stove fully open the air control This will allow chimney temperatures to remain as high as possible for as long as possible Remember cold chimney temperatures create creosote NOTE This section is intended as an aid and does not supersede any local state or like requirements Check with officials or authorities having jurisdiction in your area 20 PARTS ACCESSORIES AND OPTIONS LIST Options and trim i e brass and nickel interchange for variety Gold door and legs may also be ordered to replace
45. c tous les produits foyer y compris celui ci Respectez toutes les instructions du fabricant lors de l emploi de d tecteurs de fum e ou de monoxyde de carbone MISE EN Ce po le doit obligatoirement tre install conform ment la Norme de maisons GARDE fabriqu es et de s curit HUD CFR 3280 Part 24 et doit obligatoirement respecter les codes locaux du b timent et de pr vention des incendies Le non respect de ces instructions risque d entra ner des dommages aux biens des STOP blessures corporelles ou m me la mort Tenez les enfants les meubles les appareils et tous les produits combustibles a l cart des appareils de chauffage REMARQUE CE POELE EST AGREE POUR LES MAISONS MOBILES SIMPLES ET DOUBLES AVEC RACCORDEMENT LAIR EXTERIEUR UNIQUEMENT POUR LE MODELE AVEC PIEDESTAL PAS POUR LES MODELES A PIEDS NE PAS INSTALLER DANS UNE CHAMBRE OU L ON DORT L INT GRIT STRUCTURALE DU SOL DES MURS ET DU PLAFOND TOIT DE LA MAISON MOBILE DOIT OBLIGATOIREMENT ETRE MAINTENUE MISE EN Cet appareil doit obligatoirement tre install conform ment aux pr sentes instructions GARDE t doit obligatoirement respecter les codes locaux du b timent et de pr vention des incendies Le non respect de ces instructions risque d entrainer un feu de chemin e ou dans la maison Tenez les enfants les meubles les appareils et tous les produits combustibles a Pecart des appareils de chauffage Consultez le manuel d utilisati
46. cendie local pour tous renseignements sur la mani re de traiter un feu de chemin e Ayez un plan clairement compris pour traiter un feu de chemin e En cas de feu de chemin e fermez la commande de tirage et APPELEZ LES POMPIERS NE MANIPULEZ PAS la commande de tirage au del des r glages normaux Une fois le tirage requis obtenu ne faites fonctionner le po le qu avec les portes ferm es ouvrez les portes lentement lors du remplissage ceci r duira la fum e p n trant dans la pi ce ou Consultez notre site Web www englanderstoves com pour des renseignements utiles des questions souvent pos es des commandes de pi ces ou d accessoires etc Service client le 800 245 6489 Note sur le raccordement l air ext rieur Vous pouvez utiliser un raccordement l air ext rieur avec cet appareil Nous le pr conisons fortement pour les maisons construites depuis que des normes de construction plus herm tiques sont entr es en vigueur Ceci implique le raccordement d un tuyau en m tal en g n ral d un diam tre de trois pouces 3 po v rifiez votre po le et ce tuyau peut tre flexible ou rigide entre le tube d entr e d air situ e l arri re et en bas du po le au travers du plancher ou d un mur L extr mit de ce tuyau situ e l ext rieur doit tre couverte par exemple avec du grillage pour la prot ger des corps trangers Assurez vous de la garder au dessus de la h
47. completely away from any combustible materials The ashes should remain in the airtight container until they have completely cooled 18 IMPORTANT HELPFUL HINTS AND TIPS WORTH REVIEWING What is the correct way to start a fire You will need small pieces of dry wood kindling and paper Use only newspaper or paper that has not been coated or that has had materials glued or applied to it Never use coated or colored paper such as advertising flyers Open the door of the wood stove Crumple several pieces of paper and place them in the center of the firebox directly on the firebricks of the stove Never use a grate to elevate the fire Place small pieces of dry wood kindling over the paper in the form of a teepee This allows for good air circulation which is important for good combustion Light the crumpled paper in two or three different locations NOTE It is important to heat the air in the stovepipe for draft to begin Fully open the air control of the wood stove and close the door until it is just slightly open allowing for air to be introduced into the firebox Never leave the door fully open as sparks from the kindling may occur causing injury As the fire begins to burn the kindling some additional kindling may be needed to sustain the fire DO NOT add more paper after the fire has started Once the kindling has begun to burn start adding some small pieces of seasoned dry firewood NOTE Adding large p
48. cuit de chemin e est s r et en bon tat de fonctionnement Le fabricant ne saurait tre tenu pour responsable d un ventuel accident attribu un appareil de chauffage raccord une chemin e d fectueuse DEGAGEMENT PAR RAPPORT AUX PRODUITS COMBUSTIBLES voir l illustration 1 D y gemen par rapport au pote Pas dean thermique pour Te podis Ecrans lat raux et arri re raccord de 21 po 8 po 14 po P D P D P D chemin e a paroi simple Ecrans lat raux et arri re raccord de 20 po 5 po 14 po 12 po 5 po 12 po chemin e a paroi double REMARQUE Raccord de conduit de fum e au mur arri re C 1 Raccord paroi simple avec cran arri re 16 po 2 Raccord paroi simple avec crans arri re amp lat raux 10 po 3 Raccord paroi double avec crans arri re amp lat raux 7 po REMARQUE Raccord de conduit de fum e l angle E 1 Raccord paroi simple avec cran arri re 20 5 po 2 Raccord paroi simple avec crans arri re amp lat raux 19 5 po Veuillez noter que l AC 16 soufflerie n cessite approx 7 s il est install sur l arri re de l unit APPLICATIONS D INSTALLATION Illustration 1 REMARQUE 1 La longueur horizontale ne doit pas d passer 6 pi 2 La longueur totale du conduit de fum e ne doit pas d passer 25 pi 3 Protection du sol requise Dimension mini L 39 x H 52 5 4 V rifiez toujours les d gagements installation etc dans les codes loc
49. d de 2 pi plus haut que le f faire inspecter votre chemin e pour v rifier point le plus proche l absence de fissures ainsi que son tat g n ral du toit a 10 pi avant d installer votre appareil Il pourra tre n cessaire de refaire le gainage de la chemin e La longueur totale des pour r duire le diametre du conduit de fum e a eiseimbles d conduits Hauteur totale la dimension fonctionnelle appropri e mini par rapport Pour aider assurer un bon tirage le haut de la au sol 15 pi chemin e doit tre au moins 3 pieds au dessus du point de p n tration au travers du toit et tre au d passer 10 pieds moins 2 pieds plus haut que n importe quel point du toit se trouvant dans un rayon de 10 pieds Le conduit de raccordement ne doit pas passer dans un grenier un comble un placard un vide de construction un plancher un plafond un mur ou toute division faite de mat riaux de construction combustibles La norme CAN CSA B365 doit tre respectee s il est n cessaire de traverser un mur ou un materiau de construction combustible La hauteur minimale totale de votre chemin e doit tre de 15 pieds par rapport au sol de fum e a paroi simple ne doit pas N utilisez pas de compromis improvis pendant l installation Installation dans une maison mobile Fixer l appareil de chauffage au sol l aide des deux trous du pi destal Si l ap
50. d properly the correct clearances are achieved If you are unable to install this type system your local dealer may be able to recommend a qualified contractor for this installation It is the customers responsibility to ensure that his system is installed properly and is in good operating condition The manufacturer will not be responsible for an accident caused by a unit connected to a faulty flue system FLOOR AND WALL PROTECTION 1 Floor Protection Floor Protector You will not need any floor protection if your floor is constructed of a non combustible material Vallie 4 15 such as brick or concrete If your floor is constructed with a combustible material such as Minimum size hardwood carpet or linoleum you must place 39 VV x 52 5 D protection betvveen the stove and the combustible material There are many floor and vvall board manufacturers and you should be very cautious Illustration 2 in choosing the proper protection The type board you choose should be U L rated and listed or U L C if Canada After examining the area you plan to place your stove and determining it requires a board the next step is to select the proper size The stove you choose will determine the size board that is required The approved protector board should be large enough to provide a minimum of eight inches 8 behind the unit eight inches 8 on both sides and sixteen inches 16 in the front where the door is located The pro
51. de of the stove and along the chimney This can cause extreme danger of chimney fire To be called seasoned wood must be dried for a year Regardless of whether the wood is green or seasoned it should be stored in a ventilated sheltered area to allow proper drying during the year Wood should be stored beyond recommended clearances from combustibles DO NOT BURN Treated Wood Garbage Solvents Trash Cardboard Colored Paper or Coal FIRST FIRE CONTROL SETTINGS for Air Inlet Control Remember to ventilate well Burn Rate Inlet Air Setting Allow the stove to cure before burning for Low Fully Closed long periods of time at high temperatures Med Low 1 4 Open Med High 3 4 Open High Fully Open Flat spots on the painted surface are normal Shiny spots on the painted surface before burning are normal Call Customer Service at 800 245 6489 if you have any questions BUILDING A FIRE 1 Open the air inlet control fully NOTE The control is located under the ash drawer Pulling out on the control opens it 2 Place a small amount of crumpled paper in the stove 3 Cover the paper with a generous amount of kindling in a teepee shape and a few small pieces of wood 4 Ignite this fuel and close the door most of the way leave it open slightly 5 Add larger pieces of wood as the fire progresses being careful not to overload Do not fill the firebox beyond the firebrick area A coal bed of ideall
52. doit tre install sur un sol combustible ou sur un rev tement de sol combustible il doit alors obligatoirement tre install sur un protecteur de sol en carton non combustible de 1 po d paisseur ou un quivalent durable ayant un facteur R minimum de 1 5 unit s anglaises ou quivalent Le protecteur doit obligatoirement tre install sous l appareil et le d passer de 16 po E U du c t quip d une porte et de 8 po de tous les autres c t s Le protecteur doit obligatoirement couvrir le parcours d un ventuel raccord horizontal de chemin e en d passant de 2 po de part et d autre Autres possibilit s de protection du sol La proc dure repr sente un moyen facile pour d terminer si un protecteur de sol propos est conforme aux exigences 1 Convertissez les caract ristiques en valeur lt R gt i Une valeur lt R gt est donn e aucune conversion n est n cessaire ii Le coefficient K est fourni en m me temps qu une paisseur T en pouces R 1 k x T iii Un facteur C est fourni R 1 C 2 D terminez la valeur R du protecteur de sol propos i Utilisez la formule correcte donn e l tape 1 ci dessus pour convertir les valeurs non exprim es sous forme de R ii Dans le cas de plusieurs couches ajoutez les valeurs R de chaque couche pour d terminer la valeur lt R gt totale 3 Si la valeur lt R gt totale du syst me est sup rieure a la va
53. e action doit liminer le petit film de cr osote qui s accumule pendant les p riodes de feu au ralenti 2 Ouvrez la commande de tirage fond pendant 20 30 minutes chaque fois que vous mettez une charge de bois frais dans le po le Ceci permet au bois de se transformer en charbon de bois plus vite et consume les vapeurs de bois qui sans cela se d poseraient dans le circuit 3 N UTILISEZ QUE DU BOIS SEC vitez de br ler du bois humide ou vert Du bois sec est du bois qui a s ch pendant au moins un an 4 Un petit feu chaud est pr f rable un grand feu couvant qui d poserait de la cr osote dans le circuit 5 tablissez une routine pour la technique d allumage de chargement du bois et de br lage V rifiez tous les jours l absence de cr osote jusqu ce que l exp rience vous indique quelle fr quence le ramonage est n cessaire pour rester en s curit N oubliez pas que plus un feu est chaud moins il se d pose de cr osote et qu il peut y avoir besoin de faire un nettoyage par semaine en p riode de temp ratures moyennes alors qu un nettoyage mensuel peut suffire pendant les mois les plus froids Prenez contact avec le service d incendie local pour tous renseignements sur la mani re de traiter un feu de chemin e et ayez un plan bien compris de lutte en cas de feu de chemin e LIMINATION DES CENDRES nspectez r guli rement l accumulation de cendres dans votre po le et retirez les le cas ch ant
54. e fibre de c ramiques en deux parties Apr s une utilisation extensive il faut d poser et nettoyer le panneau Suivez les tapes ci dessous pour son nettoyage ou son remplacement 1 Assurez vous que l appareil n est pas en fonctionnement et qu il a compl tement refroidi 2 Il y a une vis dans chaque support de tube en inox situ e dans le plafond du foyer Retirez les vis des supports de l avant et du milieu 3 D placez chaque tube non fix vers la droite de mani re qu une extr mit sorte compl tement de son embase Baissez l extr mit et sortez le en le retirant vers la gauche 4 Descendez le premier panneau et poussez son coin gauche vers le haut et la gauche Abaissez le coin droit vers le coin inf rieur droit de louverture de la porte et extrayez le c t droit d abord R p tez l op ration pour la seconde partie du panneau 5 Nettoyez les panneaux avec un aspirateur et soufflez dans les tubes pour liminer le carbone le cas ch ant 6 R installez les panneaux et les tubes l inverse de la m thode ayant servi a les retirer 17 OSONLL 0S 19 OFONS 0S ON 0 s f od s opoui SAY sno Inod US 3e 0iq SIQNI s p JUIMIUUONISO saqny 3 8 1938 on A qni ouz VLAOE OV saap 047 e yuoj aqn ap np sno n SAT 066 4201 SHOAL ltun p 1808 2V ZENS 4291 SHOLL 21802 SS
55. e general condition before installing your unit Relining may be required to reduce the flue diameter to the appropriate functional size To help ensure a good draft the top of the chimney should be at least 3 feet above the point of penetration through the roof and be at least 2 feet higher than any point of the roof ee wa fue pipe within 10 feet assemblies must not 7 exceed 10 feet in The chimney connector shall not pass through overall length an attic roof space closet concealed space floor ceiling wall or any partition of combustible construction Where passage through a wall or partition of combustible construction is desired the installation shall conform with CAN CSA B365 The minimum overall height of your chimney should be 15 feet from the floor Do not use makeshift compromises during installation 2 ft higher than nearest point of roof within 10 ft Mobile Home Installation Secure the heater to the floor using the two holes in the pedestal If the unit is on a combustible surface you will need to drill matching holes in the floor protection that you choose see Floor Protection section Do not disturb the structural integrity of the home and be sure the unit is permanently electrically grounded to the chassis of your home Remember that outside combustion air is mandatory and not to install the unit in a sleeping room of the home Outside Air Connection When installing this model in a mobile home
56. e un petit lt sillon gt 1 2 po de large au milieu du lit de charbon d avant en arri re avant de mettre du combustible 7 Une fois le combustible charg fermez la porte et ouvrez fond la commande d arriv e d air jusqu ce que le feu soit bien tabli environ 20 minutes en veillant a ne pas le laisser s emballer 8 Alustez le r glage de la commande d arriv e d air pour obtenir le taux de combustion d sir Sil y a trop de fum e dans le foyer ouvrez l g rement la commande d arriv e jusqu ce que les flammes repartent et que le bois soit suffisamment enflamm En r sum ferm bas 1 2 ouvert moyen et ouvert fond fort 9 Pendant le remplissage du po le r glez le r gulateur d air en position ouvert fond Quand le feu s avive ouvrez la porte TRES lentement et soigneusement Ceci emp chera les gaz de s enflammer et de causer de la fum e et les flammes de se r pandre 10 A ce stade vous pouvez ajouter du bois en veillant a ne pas surcharger le po le N UTILISEZ JAMAIS D ESSENCE DE CARBURANT POUR LAMPE SIMILAIRE A L ESSENCE DE KEROSENE DE LIQUIDE POUR L ALLUMAGE DU CHARBON DE BOIS NI DE LIQUIDES SIMILAIRES POUR ALLUMER OU FAIRE REPARTIR UN FEU DANS CET APPAREIL DE CHAUFFAGE GARDEZ TOUS LES LIQUIDES DE CE TYPE A L ECART DE L APPAREIL DU POELE PENDANT SON FONCTIONNEMENT Moyen bas Ouvert 4 Moyen haut Ouvert 4 Compl tement ouvert
57. ente vers le haut d un quart de pouce 4 po par pied Vous devrez garder 16 pouces 16 0 de d gagement par rapport aux murs et au plafond sauf si vous utilisez un tuyau double paroi ou isol INSTALLATION Enlevez toutes les pi ces de l int rieur du po le 2 S lectionnez le meilleur emplacement pour le po le Il est interdit d installer ces appareils une distance inf rieure au d gagement minimum par rapport des mat riaux combustibles repr sent s l illustration 1 Le po le doit obligatoirement tre install sur une surface non combustible comme indiqu par les illustrations 1 et 2 _ LE NON RESPECT DES DEGAGEMENTS MINIMAUX RISQUE D ETRE LA CAUSE DE DANGERS 3 Sides mat riaux non combustibles sont install s sur les murs procurez vous les d gagements minimaux soit aupr s de leur fabricant soit aupr s des services de l inspecteur en batiment local 4 Installez le tuyau du po le A L INT RIEUR de la buse en haut du po le entre celui ci et la chemin e 5 N UTILISEZ PAS de grille pour sur lever le feu 6 Un d gagement de 16 pouces 16 0 est n cessaire entre le tuyau du po le et les mat riaux combustibles V rifiez aupr s des autorit s dont vous d pendez si vous avez la moindre question 7 Toutes les sections de tuyau doivent obligatoirement tre raccord es avec l extr mit sertie m le du c t du po le 8 Fixez le tuyau du po le la buse au moyen de trois
58. equire an adapter AC 1677 which will reduce the 6 connector pipe by s This is necessary to accommodate pipe variation from different manufacturers and maintain a good seal The area of the chimney liner must also be equal to or greater than the area of the flue collar on the stove If the area of the flue is greater than the collar it should never be more than two and 2 5 times greater The black connector pipe should be 24 gauge steel and sixteen inches 16 0 from a combustible wall or ceiling This clearance can be reduced by using double wall chimney connector or single wall chimney connector shields 3 Installation of a New Flue System Note Flue systems and flue pipe are not furnished with the unit Masonry Flue In the event that you plan to install or have a system installed there are several approaches that you can take In the middle and late seventies masonry flue systems became very popular and today this type system is satisfactory If you are considering a masonry system you should consult with your local building officials for the proper procedures on this type chimney We recommend you consult with and have your flue built by a licensed bonded contractor Most masonry chimney systems are placed against an outside wall and extend upward beside the house The flue thimble is then inserted through the wall making the connection with the stovepipe and the vertical flue Exercise extreme caution when drilling through
59. facture Date and Serial Number in space beside this sample tag for future reference This sample tag also shows the safety info such as UL ULC testing standard etc for your local officials or anyone else who may need reference information 23 Have this information on hand if you phone the factory or your dealer regarding this product Retain for your files Model Number Date of Purchase Date of Manufacture Serial LIMITED 5 YEAR WARRANTY FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties Five Year Period 1 Carbon steel and welded seams in the firebox are covered for 5 years against splitting 2 The cast iron door hasp and hinges are covered for 5 years against cracking One Year Period 3 Component parts such as stainless steel tubes and brick retainers are covered for 1 year against cracking breakage and welded seams from separating 4 Ceramic fiber board baffle electrical components accessory items glass and the painted surface are covered for 1 year from the date of purchase Conditions and Exclusions Damage from over firing will void your warranty This warranty does not apply if damage occurs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product includin
60. fond Ceci permettra aux temp ratures dans la chemin e de rester aussi lev es que possible aussi longtemps que possible N oubliez pas que ce sont les basses temp ratures dans la chemin e qui sont l origine de la cr osote REMARQUE Cette section est pr vue comme aide et ne remplace aucune exigence locale d un tat ou autres V rifiez aupr s des autorit s dont vous d pendez si vous avez la moindre question 21 LISTE DE PIECES D ACCESSOIRES ET D OPTIONS Les options et les garnitures aiton et nickel par ex peuvent tre chang es pour le d cor Vous pouvez galement commander des portes et des pieds dor s pour remplacer la porte et le pi destal ou les pieds de s rie existants PIECES DE RECHANGE AC G30 JEU DE VITRE DE PORTE AVEC JOINT AC GGK JOINT DE VITRE DE PORTE joint seul sans vitre AC DGKNC JEU DE JOINT DE PORTE joint en corde de fibres de verre haute densit AC SB BRIQUE R FRACTAIRE DE 9 X 4 X 1 4 po voir le sch ma d implantation des briques AC SB2 BRIQUE REFRACTAIRE DE 4 X 2 X 1 4 po voir le sch ma d implantation des briques AC SB2 5 BRIQUE REFRACTAIRE DE 4 X 22 X 1 4 po voir le sch ma d implantation des briques AC 30BT1 TUBE DE BR LEUR AVANT AC 30BT2 DEUXIEME TUBE DE BRULEUR partir de l avant AC 30BT3 TROISI ME TUBE DE BRULEUR partir de l avant AC 30BT4 TUBE DE BRULEUR ARRI RE AC 30CFB PANNEAU EN FIBRES DE C RAMIQUE 2 AC SH POIGNEE A RESSORT DE PORTE LAITON AC
61. g any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liability for any consequential damage for breach of any written or implied warranty is disclaimed and excluded Some states do not allow the exclusion or limitations of incidental or consequential damages so the above may not apply to you Procedure Purchaser must give notice of claim of defect within the warranty period and pay transportation to and from a service center designated by the factory The dealer from which the unit was purchased or the factory at our option will perform the warranty service Other Rights This warranty gives you specific legal rights and you may also have other rights which may vary from state to state NOTE THIS WARRANTY IS NULL AND VOID IF YOU DO NOT RETURN THE ATTACHED WARRANTY REGISTRATION WITH A COPY OF THE SALES RECEIPT WITHIN 30 DAYS FROM THE DATE OF PURCHASE WARRANTY IS NOT TRANSFERABLE 24 WARRANTY REGISTRATION for England s Stove Works Purchased by Name Address City State Zip Telephone Email Address DEALER INFORMATION Purchased From Dealer Address City State Zip UNIT INFORMATION Please be sure to refer to sticker on back of manual or box to complete this section Model Number Purchase Date Purchase Price Serial Number Mfg Date How did you first hear about our product please check one W
62. he same inside diameter as the chimney connector and having 1 in or more of insulation with a minimum 9 in air space between the outer wall of the chimney length and combustibles Sheet steel chimney connector minimum 24 gauge in thickness with a ventilated thimble minimum 24 gauge in thickness having two 1 in air channels separated from combustibles by a minimum of 6 in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness Solid insulated listed factory built chimney length with an inside diameter 2 in larger than the chimney connector and having 1 in or more of insulation serving as a pass through for a singli wall sheet steel chimney connector of minimum 24 gauge thickness with a minimum 2 in air spac between the outer wall of chimney section and combustibles Minimum length of chimney sectio shall be 12 in chimney section spaced 1 in away from connector using sheet steel support plates on both ends of chimney section Opening shall b covered and chimney section supported on both sides with sheet steel supports securely fastened tc wall surfaces of minimum 24 gauge thickness Fasteners used to secure chimney section shall not penetrate chimney flue liner INSTALLATION APPLICATIONS Cont d Illustration 1b In Canada the installation must conform to CAN CSA B365 when passing through combustible construction Pre Manuf
63. ieces at the early stages will only serve to smother the fire Continue adding small pieces of seasoned dry firewood keeping the door slightly open until each piece starts to ignite Remember to always open the door slowly when placing wood into the fire Once the wood has started to ignite and the smoke has reduced close the stove door fully Reduction of smoke is a good indication that the draft in the chimney has begun and good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to your desired setting NOTE The lower the air control setting the longer the burn time of the firewood What type of wood is best to use as firewood Dry seasoned hardwood should be used Avoid green unseasoned wood Green wood besides burning at only 60 of the fuel value of dry seasoned wood will deposit creosote on the inside of the stove and along to inside of the chimney What does dry seasoned wood mean and what is considered to be hardwood Wood that has been dried for a period of one year in a well ventilated and sheltered area is considered dry seasoned wood Hardwoods generally come from slow growth trees such as Oak or Fir Softwoods generally come from fast growth trees such as Pine or Spruce Will following the steps listed above result in a perfect fire every time A good answer would be most of the time There
64. imum clearance 12 in 305 mm of brick 2 gt E Z Chimney 0 connector Fire clay Masonry chimney liner constructed to FPA 211 Minimum chimney clearance from masonry to sheet steel supports and combustibles 2 in 51 mm Minimum clearance 9 in 229 mm Nonsoluble Factory built relracto i Chimne chimney length cement connector Chimney length ue attach connector securely Chimney Solid insulated listed factory built Masonry chimney chimney length constructed to NFPA21 Sheet steel supports Minimum chimney clearance to sheet steel supports and combustibles 2 In 51 mm Two alr channels each 1 In 25 4 mm Chimney connector Minimum 6 In 152 mm glass iber insulation nt Bt re Sheet steel constructe ons NFPA 211 supp Minimum chimney clearance to sheet steel supports and combustibles Minimum clearance 2 in 51 mm 2 in 51 mm 1 in 25 4 mm air space to chimney length mney Chimney connector Chimney length Masonry chimney Sheet steel constructed supports to NFPA 211 Minimum 3 5 in thick brick masonry all framed into combustible wall with a minimum of 12 in brick separation from clay liner to combustibles The fireclay liner shall run from outer surface of brick wall to but not beyond the inner surface of chimney flue liner and shall be firmly cemented in place Solid insulated listed factory built chimney length of t
65. istrer sur Internet 27
66. lado del motor de soplador Le ventilateur en option de circulation de chaleur sur ce po le n cessite un graissage p riodique cette lubrification doit tre effectu e au moins tous les trois mois de fonctionnement normal Pour lubrifier correctement le ventilateur utilisez un compte gouttes ou un dispositif semblable de distribution pour faire couler 5 7 gouttes d huile SAE 20 dans l orifice cet effet situ sur le c t du moteur du ventilateur ALWAYS FOLLOW ALL CODES AND OWNER S MANUALS SIEMPRE SIGA TODOS LOS C DIGOS Y MANUALES DEL PROPIETARIO TOUJOURS SUIVRE TOUS LES CODES ET LES MODES D EMPLOI 11 SOUFFLANTE EN OPTION Ecouter AC 30 Blower Installation Instruction Guide Guia de instrucciones de instalaci n del ventilador AC 30 Guide d installation du ventilateur AC 30 For our freestanding models with 30 in model number Para nuestros modelos de pie con 30 en el n mero de modelo Pour nos mod les sur pieds avec un num ro de mod le 30 1 Remove the four 4 screws size 5 16 and the cover plate from the rear heat shield 1 Retire los cuatro 4 tornillos de 5 16 y la placa de cubierta del protector t rmico posterior 1 Retirer les quatre 4 vis 5 16 po 8 mm et la plaque de protection l arri re de l cran de chaleur 2 Position the blower orienting the fan so that it will blow air upwards and between the heat shield and the back of the stove s firewall
67. lation d un circuit pr fabriqu consiste sortir par le mur et faire cheminer les tuyaux verticalement l ext rieur de la structure Cette m thode est plus ch re parce qu elle n cessite davantage de tuyauterie isol e il faut utiliser un tuyau isol au travers du mur et l ext rieur de la structure Quelle que soit le type d installation choisie il faut maintenir les d gagements corrects par rapport aux mat riaux combustibles Le fabricant de votre conduit de fum e fournit un manchon d emboftement ou une bo te de support au plafond quand l un ou l autre est install correctement les d gagements corrects sont r alis s Si vous ne pouvez pas installer ce type de conduite votre concessionnaire local pourra vous recommander un entrepreneur qualifi pour cette installation C est la responsabilit du consommateur de s assurer que le conduit est s r et en bon tat de fonctionnement Le fabricant ne saura tre tenu pour responsable d un ventuel accident caus par un appareil de chauffage raccord un conduit de fum e d fectueux PROTECTION DU SOL ET DES MURS 1 Protection du sol Vous n aurez pas besoin de protection du sol si Protection de celui ci est en mat riau non combustible briques Eee ou b ton par ex Si votre sol est en mat riau combustible en bois dur en moquette ou en linoleum par exemple il faut obligatoirement Taille interposer une protection entre le po le et
68. ld be followed for replacement of the glass gasket 1 Ensure that the appliance is not in operation and is thoroughly cooled 2 Remove the screws and glass holders 3 Lift glass out 4 Remove the old gasket and clean the glass 5 Replace the new gasket starting at the bottom of the glass and working along the edges Be sure to center the gasket channel on the glass 6 Trim the gasket to length and butt the ends together 7 Replace the glass and holders in the door Tighten being sure not to over tighten the screws You may order parts and options on our web site www englanderstoves com or by calling 800 516 3636 parts orders only call 800 245 6489 for technical questions 15 The following steps should be followed for replacement of the door gasket 1 2 Ensure the appliance is not in operation and is thoroughly cooled Remove the old door gasket and clean the gasket channel Using an approved high temperature gasket cement apply a thin coat in the bottom of the channel Starting at the hinge side of the door work into the channel around the door unit trim to length and butt the ends together Close the door and allow three to four hours for the cement to set before restarting any fire FIBER BOARD CARE amp MAINTENANCE THIS WOOD HEATER UTILIZES NEW TECHNOLOGY WHICH INCLUDES CERAMIC FIBER BOARD THAT IS LOCATED IN THE FIREBOX AND RESTS ON TOP OF FOUR STAINLESS STEEL TUBES DO NOT REMO
69. leur R gt du protecteur de sol sp cifi l autre choix est acceptable EXEMPLE Le protecteur de sol sp cifi doit tre un mat riau de 3 4 po d paisseur ayant un coefficient K de 0 84 L autre choix propos est de la brique de 4 po ayant un facteur C de 1 25 sur une planche de type min ral de 1 8 po ayant un coefficient K de 0 29 Etape a Servez vous de la formule ci dessus pour convertir les sp cifications en valeur lt R gt R 1 k x T 1 0 84 x 0 75 0 893 Etape b Calculez le R du syst me propos Brique de 4 po avec C 1 25 par cons quent le R de la brique 1 C 1 1 25 0 80 Planche de type min ral de 1 8 po avec k 0 29 par cons quent Rmini de la planche 1 0 29 x 0 125 0 431 R Total Rbrique Rplanche min rale 0 8 0 431 1 231 tape c Comparez la valeur R 1 231 au R sp cifi de 0 893 Le R du syst me propos tant sup rieur la valeur requise le syst me est acceptable D finitions Conductance thermique C Btu W hr pi deg F m deg K Conductivit thermique _ Btu pouce W Btu hr pi deg F m deg K hr ft deg F R sistance thermique R pi hr deg F m deg K Btu W 2 Protection des murs Voir l illustration 1 pour les d gagements par rapports aux murs Dans certains endroits les codes locaux exigent trente six pouces 36 po par rapport un mat riau combustible par cons quent il est tr s important de v
70. ll be reversed If you use this method the creosote will run back down the inside of your pipe and not out of the joints onto your stove As a safety precaution all joints must be held together by at least three 3 sheet metal screws For proper operation the chimney connector should be as short as possible and never exceed a six foot 6 horizontal run Horizontal runs of chimney connector pipe should have an upward slope of one quarter of an inch 4 per foot You will need to maintain sixteen inches 16 0 of clearance from the wall and ceiling unless you are using double wall or shielded pipe INSTALLATION Remove all parts from inside the stove body 2 Select the proper location for the stove These appliances must not be installed any closer than the minimum clearance to combustible materials shown in Illustration 1 The stove must be installed on a non combustible surface as shown in Illustration 1 and Illustration 2 FAILURE TO FOLLOW THE MINIMUM CLEARANCE REQUIREMENTS MAY RESULT IN AN UNSAFE INSTALLATION 3 If non combustible materials have been installed on the walls obtain the minimum clearances from either the manufacturer of these materials or the local building inspector s office 4 Install the stovepipe INSIDE the flue collar on the top of the stove between the stove and the chimney 5 DO NOT use a grate to elevate the fire 6 Aclearance of 16 0 inches between the stovepipe and combustible materials is required
71. lowing use and safety tips should be observed 1 Inspect the glass regularly for cracks or breaks If you detect a crack or a break extinguish the fire immediately and contact your dealer or Customer Service at 800 245 6489 for replacement or log on to www englanderstoves com 2 Do not slam the door or otherwise impact the glass When closing door make sure that logs or other objects do not protrude and impact the glass 3 Do not clean the glass with materials which may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or breaks 4 Never attempt to clean the glass while the unit is hot If the deposit is not very heavy normal glass cleaners are adequate with a plain non abrasive scouring pad Heavier deposits may be removed with the use of an oven cleaner 5 NEVER put substances that can ignite explosively inside the unit since even small explosions in confined areas can blow out the glass 6 This unit has an airwash system designed to reduce deposits on the glass GASKET REPLACEMENT After extensive use the sealing material which provides glass and door seal may need to be replaced if it does not sustain its resilience Inspect the glass and door seal periodically to ensure proper seal If the gaskets become frayed or worn replace immediately Contact your dealer or Customer Service at 800 245 6489 or www englanderstoves com for approved replacement parts The following steps shou
72. mula given in step 1 above to convert values not expressed as R ii For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable EXAMPLE The specified floor protector should be 32 thick material with a k factor of 0 84 The proposed alternate is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare proposed system of R of 1 231 to specified R of 0 893 Since proposed system R is greater than required the system is acceptable Definitions Thermal conductance C Btu W hr ft deg F m deg K Thermal conductivity k _ Btu inch W Btu hr ft deg F m deg K hr ft deg F Thermal resistance R ft hr deg F m deg K Btu W 2 Wall Protection Please see Illustration 1 for clearances to walls In some areas local codes may require thirty six inches 36 from a combustible therefore it is very important that you check with local officials If you need to place y
73. nimale de 9 po entre le mur ext rieur de la longueur de chemin e et les mat riaux combustibles Raccord de chemin e en t le d acier d paisseur n 24 au minimum avec un manchon d embo tement ventil d paisseur n 24 au minimum ayant deux conduits d air de 1 po s par des mat riaux combustibles par de Pisolant en fibre de verre d une paisseur minimale de 6 po L ouverture doit obligatoirement tre couvert et le manchon d embo tement soutenu par un support en t le d acier d paisseur n 24 au minimum Longueur de chemin e pr fabriqu e isolation pleine homologu e ayant un diam tre int rieur 2po plus grand que le raccord et ayant au moins 1 po de rev tement isolant pour servir de gaine un raccord paroi simple en t le d acier d paisseur n 24 au minimum avec une lame d air minimale de 2 po entre le mur ext rieur de la section de chemin e et les mat riaux combustibles La longueur minimale de la section de chemin e doit obligatoirement tre une section de chemin e de 12 po espac e de 1 po du raccord au moyen de plaques support en t le d acier aux deux extr mit s de la section de chemin e L ouverture doit obligatoirement tre couverte et la section de chemin e soutenue des deux c t s avec des supports en t le d acier solidement fix s aux surfaces des murs d paisseur n 24 au minimum Les l ments servant la fixation de la section de chemin e ne devront pas p n trer
74. on pour ce qui concerne les d gagements par rapport aux mat riaux combustibles CONSERVEZ CE MANUEL POUR R F RENCE ULT RIEURE Lisez la totalit de ce manuel avant d installer et d utiliser votre nouvel appareil de chauffage individuel Si cet appareil de chauffage individuel n est pas install correctement il peut causer un incendie Pour r duire le risque d incendie suivez les instructions d installation Le non respect des instructions risque d entra ner des dommages aux biens des blessures corporelles ou m me la mort ANTERTE4 Pour un service en Francais Courriel Rev 8 30 2012 Canada French infoenfrancais englanderstoves com Telephone 514 358 3385 Se CA 2705 nock yet Lettre de notre service d aide technique Merci d avoir achet cet excellent produit d England s Stove Works England s Stove Works a t cr par une famille qui l entreprise appartient encore qui croit tr s fort l esprit du faites le vous m me c est une raison pour laquelle vous avez trouv ce produit dans votre magasin de bricolage favori C est intentionnellement que nous concevons et fabriquons nos po les de mani re que tout propri taire puisse entretenir le sien avec des outils de base et nous sommes toujours contents de vous montrer comment faire le travail aussi facilement et aussi bon march que possible De nos documents d entretien gratuits telechargeables a not
75. ons n cessaires ou sinon recommander une personne qualifi e pour les effectuer Il n est pas permissible de raccorder ce po le une chemin e si un autre appareil de chauffage y est d j raccord 2 Taille du conduit de fum e La taille correcte pour le conduit de fum e est d termin e en mesurant le diam tre int rieur de la buse du po le Le po le est quip d une buse vacuation par le haut de six pouces 6 po Par cons quent le tuyau de raccordement doit avoir un diam tre de six pouces 6 po et ne doit jamais avoir un diam tre inf rieur la buse du po le Il se peut que votre po le n cessite un adaptateur AC 1677 qui r duira le diam tre du tuyau raccord de 6 po de 1 8 po C est n cessaire pour accommoder les diff rences entre des tuyaux provenant de diff rents fabricants tout en maintenant une bonne tanch it La section de la gaine de la chemin e doit aussi obligatoirement tre gale ou sup rieure la section de la buse du po le Si la section du conduit de fum e est sup rieure celle de la buse elle ne doit jamais d passer deux fois et demi 2 5 fois celle ci Le tuyau de raccordement noir doit tre en acier d paisseur n 24 et doit tre situ 16 pouces 16 0 des murs ou des plafonds combustibles Cet espace peut tre r duit en utilisant des blindages de connecteurs de chemin es murales doubles ou simples 3 Installation d un conduit de fum e neuf Remarque
76. or double wide it is necessary to supply the combustion air into the unit from outside the dwelling NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE PEDESTAL MODEL ONLY NOT FOR LEG MODELS This can be done by running a thin gauge three inch 3 pipe flex or rigid from the air inlet pipe located on the rear of the stove through the floor or wall measure pipe to ensure you obtain the correct size The outside end of this pipe should be covered in some manner i e screen to keep it clear of foreign matter Be sure to keep it above the snovvdrift line and clear of leaves and other debris If you are installing this stove in a regular dwelling this connection is not necessary but is recommended in air tight homes A kit is available from England s Stove Works Inc designed for connecting this unit to outside combustion air Part No AC OAK3 13 OPERATION Do not use a grate or elevate the fire Build the wood fire directly on the bricks When the stove is used for the first time solvents in the paint will smoke off as the stove cures WOOD This heater is designed to burn natural wood only Higher efficiency and lower emissions generally result when burning air dried seasoned hardwood as compared to softwood or to green or freshly cut hardwood Use only dry seasoned wood Green wood besides burning at only 60 percent of the fuel value of dry wood deposits creosote on the insi
77. ord of Mouth Burn Trailer Demonstration nternet Other V here did you receive information about our product please check one Recd info via phone Dealer Name of dealer nternet Other IMPORTANT NOTICE THIS REGISTRATION INFORMATION MUST BE ON FILE FOR THIS WARRANTY TO BE VALID PLEASE MAIL THIS INFORMATION WITHIN THIRTY 30 DAYS FROM THE DATE OF PURCHASE Mail To England s Stove Works Inc Customer Service Department P O Box 206 Monroe VA 24574 Or Fax To 434 929 4810 24 hours a day Or now available Go online to complete your Warranty Registration Visit www englanderstoves com if you prefer to register online 26 MANUEL D INSTALLATION amp DE FONCTIONNEMENT NUM ROS DE MOD LES 30 NCP 50 SNC30P 50 TNC30P 30 NCL 50 SNC30L 50 TNC30L 30 NCG 50 SNC30G 50 TNC30G Merci d avoir achet de produit qui fait partie d une excellente gamme d equipemenis de chauffage Nous vous souhaitons de nombreuses ann es de confort en s curit avec votre nouvel appareil de chauffage Conservez ces instructions IMPORTANT EN CAS DE PROBL ME AVEC CET APPAREIL NE LE RAPPORTEZ PAS AU CONCESSIONNAIRE COMMUNIQUEZ AVEC LE SERVICE CLIENTELE AU 1 800 245 6489 Questions Besoin de pi ces ou d options www englanderstoves com Veuillez noter les mises en garde ci dessous England s Stove Works pr conise fortement l emploi de d tecteurs de fum e et de d tecteurs de monoxyde de carbone ave
78. our unit closer to a combustible wall some protection will be necessary If an approved wall board is used this will reduce your clearance by two thirds 2 3 however a one inch 1 air space has to be between the board and the wall If you have a ceiling flue hook up you will need protection from the floor to the ceiling if you do not meet the normal clearances If you have a wall flue hook up you will need wall protection at least twelve inches 12 above the wall thimble 3 Side Heat Shields This accessory item comes with the hardware six 6 mounting screws necessary to install it on the rear of the stove This is a two piece heat shield but is installed one piece at atime There are pre punched holes on each side of the Rear Heat Shield while holding each piece of the Side Heat Shield in place align the pre punched holes in the Side Heat Shield with the existing holes in the Rear Heat Shield and fasten with the screws provided See Illustration 1 for clearances with and without side heat shields All Unmarked Brick are Size 1 Illustration 4 Side Heat Shield Rear Heat Shield Heat Shield Install AC 30 Optional Blower on these 4 mounting holes See Optional Blower Instructions Illustration 3 Side Heat Shield and Blower Installation BRICK LAYOUT 1 Unmarked on diagram 9 x 4 x 1 4 brick Qty 25 2 4 x 2 x 11 4 brick Qiy 1 10 3
79. ous pouvez maintenant ajouter de gros morceaux de bois sec quand il y a suffisamment de place pour eux dans le foyer R gler le r gulateur d air l ouverture d sir e REMARQUE Moins le r gulateur d air est ouvert plus longtemps le bois br lera Quel est le meilleur type de bois de chauffage l est pr f rable d utiliser du bois de chauffage bien sec Evitez le bois vert non s ch Le bois vert en plus du fait qu il ne contient que 60 de la valeur calorifique du bois sec d posera de la cr osote l int rieur du po le et de la chemin e Qu est ce que vous voulez dire par bois sec et qu est ce qu on entend par bois dur On consid re que du bois sec est du bois ayant s ch pendant un an a un endroit l abri et bien a r Le bois dur provient g n ralement d arbres a la croissance lente par exemple le ch ne ou le sapin Le bois tendre provient g n ralement d arbres croissance rapide exemple le pin ou l pic a Est ce que je r ussirai avoir un feu parfait chaque fois en suivant le mode d emploi ci dessus Une bonne r ponse est lt la plupart du temps gt l y a de nombreuses variables qui jouent sur votre taux de r ussite allumer un feu et c est experience qui vous enseignera comment traiter ces variables Cette section du manuel couvrira quelques unes des variables qui peuvent avoir un effet sur un feu et le temps ainsi que la patience contribueront votre ca
80. pacit allumer un bon feu de mani re constante Pourquoi est ce que je ne peux pas allumer le feu Du bois humide ou mouill et un mauvais tirage sont les causes principales des mauvais r sultats l allumage d un feu Rappelez vous de toujours vous servir de bois sec pour faire du feu M me si le bois a s ch pendant longtemps il s allumera difficilement s il est mouill Pourquoi est ce qu il y a toujours une grande quantit d paisse fum e noire dans le foyer Une grande quantit d paisse fum e noire dans le foyer indique un mauvais tirage possible 20 7 Est ce qu il est normal que la vitre soit couverte de suie au d but d un feu Ce po le est quip d un syst me purateur d air qui aide a garder la vitre propre quand le foyer a atteint une bonne temp rature de fonctionnement et qu il y a aussi un bon tirage Ce sont une temp rature froide du foyer et un mauvais tirage qui causent la formation de suie sur la vitre Une fois que la temp rature du foyer et le tirage augmentent la suie doit se dissiper 8 Qu est ce que c est que le tirage Le tirage est la capacit de la chemin e a vacuer les sous produits engendr s pendant le processus normal de combustion 9 Qu est ce qui cause un mauvais tirage Plusieurs facteurs peuvent contribuer un mauvais tirage A La pression atmosph rique et l alimentation en air B La pression atmosph rique ayant une incidence sur le tir
81. pareil est sur une surface combustible vous devrez percer des trous correspondants dans le protecteur de sol que vous choisirez voir la section lt Protecteur de sol Ne portez pas atteinte l int grit structurale de la maison et assurez vous que l appareil de chauffage est mis la terre en permanence par rapport au ch ssis de votre maison Rappelez vous que de l air provenant de l ext rieur est obligatoire pour la combustion et de ne pas installer l appareil dans une chambre Raccordement d air ext rieur Lors de l installation de ce mod le dans une maison mobile simple ou double il est n cessaire de fournir l appareil de l air pour la combustion provenant de l ext rieur de la maison REMARQUE POELE EST AGREE POUR LES MAISONS MOBILES SIMPLES ET DOUBLES AGR ES AVEC RACCORDEMENT A LAIR EXT RIEUR UNIQUEMENT POUR LE MOD LE AVEC PI DESTAL PAS POUR LES MODELES A PIEDS Ceci s effectue a l aide d un tuyau mince de trois pouces 3 po flexible ou rigide entre le tuyau d entr e d air l arri re du po le et l ext rieur au travers du sol ou d un mur mesurez le tuyau pour tre s r d obtenir la bonne taille L extr mit de ce tuyau situ e a l ext rieur doit tre couverte par exemple avec du grillage pour la prot ger des corps trangers Assurez vous qu elle soit bien au dessus de la hauteur de la neige et d gag e des feuilles et autres d bris Si vous installez ce po le dans une maison normale
82. ques et mat rinn combustibles 2po 5lmm Raccord de la chemin e Utiliser des pi ces _ Supports ent le d acier D gagemert minimum de la chemin e entre masormerie et supports ent le d acier briques 2po 5lmm 6 po 152 mm mirumum parrapport l isolation Deux conduits en fibre de verre ipo astm po mm r daam Construction Chemin e marorm e Supports ent le d acier entole d acier conforme D gagemert mirumum de la chemin e entre ma ormerie et supports ent le d acier briques et mat rinx combustibles ds 2po 51mm D gagemert minimum Supports en t l d acier Section de chemin e 2po lmm Lame ih 1 mpo 25 rit Raccord de la chemin e Lame d air 2po 5lmm 21 Chemin e ma onn e Supports en t le d acier s x all 211 A En brique ma onn es ayant une paisseur minimale de 3 5 po enti rement encastr e dans le mur avec un cadre et ayant une s paration minimale de 12po par des briques entre le boisseau en argile et les mat riaux combustibles Le boisseau en argile doit aller de la surface ext rieure du mur en briques jusqu la surface int rieure de la gaine de la chemin e il doit tre ciment fermement en place Longueur de chemin e pr fabriqu e isolation pleine homologu e ayant le m me diam tre int rieur que le raccord et ayant au moins 1 po de rev tement isolant avec une lame d air mi
83. rdance with these instructions and must comply with local building and fire codes Failure to do so could result in a chimney or house fire Keep children furniture fixtures and all combustible materials away from any heating appliance Refer to this owner s manual for all clearances to combustible materials SAVE THIS MANUAL FOR FUTURE REFERENCE Read this entire manual before you install and use your new room heater If this room heater is not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death ANTERTE4 Rev 8 30 2012 Canada English EH n A letter from our Technical Support Department Thank you for purchasing this fine product from England s Stove Works England s Stove Works was started and is still owned by a family that believes strongly in a Do It Yourself spirit that s one reason you found this product at your favorite Do It Yourself store We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools and we re always more than happy to show you how to do the job as easily and as inexpensively as possible From our free downloadable service sheets to our Pellet Service Video to our new vvizard style click through Troubleshooting guide on our web site we have always tried to help our customer
84. re sauter la vitre 6 Le po le est muni d un syst me de nettoyage de l air con u pour r duire les d p ts sur la vitre REMPLACEMENT DU JOINT Apr s une utilisation prolong e il pourra tre n cessaire de remplacer le mat riau qui assure l tanch it de la vitre et de la porte s il perd sa souplesse Inspectez p riodiquement les joints de la vitre et de la porte pour assurer qu ils assurent bien l tanch it Si les joints s effilochent ou sont us s remplacez les imm diatement Prenez contact avec votre concessionnaire ou le service client le au 800 245 6489 ou www englanderstoves com pour ce qui concerne les pi ces de rechanges agr es Suivez les tapes ci dessous pour remplacer le joint de la vitre 1 Assurez vous que l appareil n est pas en fonctionnement et qu il a compl tement refroidi 2 Enlevez les vis et les supports de la vitre 3 Extrayez la vitre en la soulevant 4 Retirez le vieux joint et nettoyez la vitre 5 Mettez en place le joint neuf en commen ant par le bas de la vitre et en remontant le long des bords Assurez vous que le centre du joint est sur le rebord de la vitre Coupez le joint a la bonne longueur et mettez les deux extr mit s bout a bout 7 Remettez la vitre et ses supports dans la porte Serrez les vis en veillant a ne pas trop les serrer Vous pouvez commander des pi ces et des options sur notre site Web www englanderstoves com ou en t l phonant au 8
85. re vid o d entretien Pellet en passant par notre guide de d pannage lt intelligent gt sur notre site Web nous avons toujours essay d aider nos clients a rester lt pr ts chauffer gt tout particuli rement quand les tarifs de Phuile et de l lectricit continuent d augmenter N h sitez pas consulter l importante section d aide sur notre site Web et appeler notre service client le au 800 245 6489 si vous avez besoin d aide avec votre po le Nous pouvons presque toujours vous aider effectuer n importe quelle r paration r gler un probl me ou r pondre aux questions que vous vous posez VEUILLEZ NOTER QUE Si les renseignements disponibles sur notre site Web et par l interm diaire de notre num ro 800 sont toujours gratuits il y aura des frais de service dans le cas de r paration ou d entretien effectu chez vous et arrang par nous Nous vous souhaitons de longues ann es de chauffage efficace de qualit et confortable England s Stove Works Service d aide technique www englanderstoves com 800 245 6489 EN CAS DE PROBLEME AVEC CET APPAREIL NE LE RAPPORTEZ PAS AU CONCESSIONNAIRE PRENEZ CONTACT AVEC LE SERVICE CLIENTELE AU 1 800 245 6489 MISE EN GARDE Si vous avez le moindre doute a propos de votre capacit a effectuer votre installation professionnellement apr s avoir lu ces instructions nous vous recommandons d obtenir les services d un installateur comp tent d
86. rifier aupr s des autorit s locales Si vous avez besoin de mettre votre appareil plus pr s d un mur combustible une protection sera n cessaire Si un panneau mural est utilis il r duira votre d gagement des deux tiers 2 3 toutefois une lame d air d un pouce 1 po est n cessaire entre le panneau et le mur Si vous avez une vacuation par le plafond vous aurez besoin d une protection du sol au plafond au cas o vous n auriez pas les d gagements normaux Si votre tuyau de conduit de fum e passe par le mur vous aurez besoin d une protection murale sur au moins douze pouces 12 po au dessus du manchon d embo tement dans le mur 3 Ecrans thermiques lat raux Ecran thermique Cet accessoire est livr avec la quincaillerie six 6 vis necessaire pour Tinstaller a l arri re du po le Il s agit d un Beri cran thermique en deux a thermique morceaux mais il s installe une partie la fois Il y a des trous pr perc s de chaque c t de l cran thermique arri re tout Goran en maintenant chaque morceau thermique d cran thermique lat ral en lat ral Installez la soufflante en option place alignez les trous pr AC 30 sur ces 4 trous de perc s de l cran lat ral avec Jixation Voir les instructions les trous existants dans l cran Soufflante en option thermique arri re et fixez les l aide des vis fournies Illustration 3 installation de l cran thermique lat ral et
87. s stay heat ready especially when oil and electricity prices continue to skyrocket Please look at our vast Help section on our web site and call our Customer Service department at 800 245 6489 if you need any help with your unit We are nearly always able to help walk you through any repairs problems or questions you may have PLEASE NOTE While information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Wishing you years of efficient quality and comfy heating England s Stove Works Technical Support Department www englanderstoves com 800 245 6489 IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER CONTACT CUSTOMER SERVICE at 1 800 245 6489 CAUTION If you have any doubt concerning your ability to complete your installation in a professional like manner after reading these instructions you should obtain the services of an installer who is versed in all aspects as to the correct and safe installation Do not use temporary makeshift compromises during installation BEFORE INSTALLATION OF YOUR APPLIANCE 1 HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS 2 DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS 3 Check with the building inspector s office for compliance with local codes a permit may be required
88. se de la soufflante doit tre r gl e sur lt Bas gt quand le po le fonctionne avec une combustion lente et sur lt Haut gt quand le feu est vif Pour le cheminement du cordon d alimentation veillez ce que celui ci n entre en contact avec aucune surface chaude For our freestanding models with 30 in Install AC 16 Optional Blower as shown using the 4 model number supplied mounting screws Para nuestros modelos de pie con 30 en el Instale el ventilador opcional AC 16 como se muestra n mero de modelo usando los tornillos de montaje suministrados 4 Pour nos mod les sur pieds avec un num ro de Installer le ventilateur optionnel AC 16 comme indiqu mod le 30 l aide des 4 vis de fixation fournies The optional heat circulation blower on this stove requires periodic lubrication this lubrication should be performed no less than every three months of normal operation To properly lubricate the blower use an eye dropper or similar dispensing device to drip 5 7 droplets of SAE 20 oil into the oil port on the side of the blower motor El soplador de circulaci n de calor opcional en esta estufa requiere la lubricaci n peri dica esta lubricaci n no deber a ser realizada menos que cada tres meses de la operaci n normal Para lubricar correctamente al soplador use un cuentagotas o el dispositivo de distribuci n similar para gotear 5 7 gotitas de SAE 20 petr leo en el puerto del aceite en el
89. stallation de fonctionnement incorrect ou de r parations ou de tentatives de r paration non autoris es Le fabricant n est pas responsable des dommages int r ts immat riels indirects ou accessoires li s au produit y compris les ventuels co ts ou d penses de fourniture d un quipement ou service de remplacement pendant les p riodes de dysfonctionnement ou de non utilisation Toute responsabilit pour les ventuels pr judices indirects de violation d une garantie crite ou implicite est d clin e et exclue Certains tats n autorisent pas l exclusion ou les limites des dommages int r ts accessoires de ce fait il se peut que les limites ci dessus ne s appliquent pas vous Proc dure L acheteur doit obligatoirement pr venir du sinistre ou du d faut pendant la p riode de garantie et payer les frais de transport aller et retour jusqu au centre de service d sign par l usine A notre choix c est le concessionnaire a qui l appareil a t achet ou lusine qui effectuera le service en garantie Autres droits La pr sente garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits qui peuvent varier d un tat un autre REMARQUE LA PR SENTE GARANTIE EST NULLE ET NON AVENUE SI VOUS NE RENVOYEZ PAS LE FORMULAIRE D ENREGISTREMENT DE LA GARANTIE CI JOINT AVEC UNE COPIE DE LA FACTURE DANS LES 30 JOURS SUIVANT LA DATE DE L ACHAT LA GARANTIE N EST PAS TRANSFERABLE
90. t lower burn settings and set to High for high burns See Illustration 3 on the previous page Side Heat Shields for installation location of your optional blower Remove rectangle cover plate if installed Fasten blower motor to rear heat shield with the four screws that are provided with your unit Air should flow upwards when installed When routing power cord be sure that the cord does not come into contact with any hot surface 11 FREESTANDING PLACEMENT AND INSTALLATION The first problem you may encounter is getting your stove into your home all of our stove products are well constructed which makes them rather heavy Three to four adults can normally handle a unit but we still recommend using a handcart Never attempt to handle a heating product alone The door and brick can be temporarily removed to lighten the unit refer to Brick Layout After the unit is placed into position install the spring handles and attach any optional equipment Chimney Connector Pipe The black pipe must be six inches 6 in diameter and at least 24 gauge steel pipe Do not use aluminum or galvanized steel pipe as it will not withstand the extreme temperatures generated by the stove Also do not use single wall connector pipe as a chimney you must connect your stove to a chimney comparable to those listed earlier in this manual The crimped end of your pipe should be inserted into the flue collar and by doing this all the pipe wi
91. tection must have an R value of 1 5 English units or equivalent See Installation on a Combustible Floor This stove requires a minimum 39 0 x 52 5 floor protection Installation on a Concrete Floor An appliance mounted on a concrete floor does not require floor protection Carpeting and any other combustible material must not cover the Floor Protector If a combustible surface is applied to the concrete floor a clearance must be maintained equivalent to the area reserved for the floor protector Installation on a Combustible Floor If the appliance is to be installed on a combustible floor or a combustible floor covering it must be installed on a 1 thick non combustible millboard floor protector or a durable equivalent with a R factor of at least 1 5 English units or equivalent The pad must be installed beneath the unit extending 16 U S on the side equipped with a door and 8 on all other sides The pad must cover any horizontal chimney connector runs and extend 2 beyond each side Alternate Floor Protection An easy means of determining if a proposed alternate floor protector meets requirements is to follow this procedure 1 Convert specification to R value i R value is given no conversion is needed ii k factor is given with a required thickness T in inches R 1 k x T ili C factor is given R 1 2 Determine the R value of the proposed alternate floor protector i Use the correct for
92. the wall you must maintain proper clearance between the connecting liner and any combustible material in the wall We also recommend you have a flue clean out door located at least two feet 2 below your thimble for easy cleaning of the system This door should be made as airtight as possible It is the consumer s responsibility to ensure the chimney system is safe and in good operating condition The manufacturer will not be held responsible for an accident attributed to a unit connected to a fault chimney system 1 Side A Rear B Comer Side A Rear B Corner Side and Rear shields single 21 in 8 in 15 in N A N A N A t be R wall connector NOTE Flue Connector to back wall C Single wall connector with rear shield 16 Single wall connector with rear amp side shields 10 Double wall connector with rear amp side shields 7 NOTE Flue Connector to corner E Single wall connector with rear shield 20 5 Single wall connector with rear amp side shields 19 5 Please Note that the AC 16 blower requires approx 7 if installed on the rear of the unit INSTALLATION APPLICATIONS Illustration 1 NOTE 1 Horizontal run not to exceed 6 2 Total flue length should not exceed 25 3 Floor protection required Min size 39 x 52 5 4 Always check local codes for clearances installation etc 18 0 Min Masonry Chimney Single Wall
93. y 1 to 2 should be established to achieve optimum performance 6 This unit is designed to function most effectively when air is allowed to circulate to all areas of the firebox A good way of achieving this is to rake a small 1 to 2 wide trough in the center of the coal bed from front to back prior to loading the fuel 7 Once fuel has been loaded close the door and fully open the air inlet control until the fire is well established approximately 20 minutes being careful not to over fire 8 Readjust the air inlet control to the desired burn rate If excessive smoke fills the firebox open the air inlet control slightly until flames resume and the wood is sufficiently ignited Basically Closed Low Y Way Open Medium and Fully Open High 9 When refueling adjust the air control to the fully open position When the fire brightens open the door VERY slowly and carefully This will prevent gases from igniting and causing smoke and flame spillage 10 At this point you may add fuel being careful not to overload NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE 14 GLASS CARE WARNING DO NOT USE SUBSTITUTE MATERIALS REPLACE GLASS ONLY WITH HIGH TEMPERATURE ROBAX PYROCERAM OF THE PROPER SIZE AND THICKNESS The fol
Download Pdf Manuals
Related Search
Related Contents
Kodak 2.2 User's Manual conhecer para prevenir pórticos e pontes rolantes TDM-NC1 Albrecht ae 6690 - Alan-Albrecht Service H26.7月学校懇談会資料 Instructions for use Instrucciones de uso Manual de utilização Avesnelles - Parc naturel régional de l`Avesnois Discours - Associations.gouv.fr Micw42 GB-NL-FR-ES-D-IT Copyright © All rights reserved.