Manuel d`installation

image

Contents

1. riaux contribue la conservation des EE ESSOUrCES naturelles Pour avoir des informations plus d taill es pri re de contacter le bureau pr pos de la ville int ress e le service de ramassage des d chets ou le revendeur du produit PYRO CONTROLE 694082A00 Ed1 FRAN AIS 8 8 CHAUVIN ARNOUX GROUP PYRO CONTROLE CHAUVIN ARNOUX GROUP gt PDM Line PDM 10D0O Modbus module with 10 MOSFET digital outputs N Installation Manual Contents General specifications Technical specifications Modbus connections rules Installation rules Electrical connections DIP switches settings Modbus basic register and LEDs signaling Factory settings and advanced settings PYROCONTROLE Groupe Chauvin Arnoux 6bis Av Dr Schweitzer 69881 MEYZIEU Cedex FRANCE Tel 33 0 4 72 14 15 40 Fax 33 0 4 72 14 15 41 For manuals and configuration software please visit www pyrocontrole com This document is property of Pyrocontrole Duplication and reprodution are forbidden if not authorized Contents of the present documentation refers to products and technologies described in it All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 ED1 ENGLISH 1 8 GENERAL SPECIFICATIONS 10 MOSFET outputs with shared negative pole the outputs can be c
2. ms PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 Ed1 ENGLISH 2 8 Power supply 10 40 Voc 19 28 Vac 50 60 Hz Voltage Consumption Typical 1 5 W Maximum 2 5 W Environmental condition Temperature 10 65 C 10 55 C UL Humidity 30 90 a 40 C not condensing Altitude Up to 2000 m a s l Storage Temperature 20 85 C Degree protection IP20 Connections Removable 3 way screw terminals 5 08 pitch Connections Rear IDC10 connector for DIN 46277 rail Box Dimensions Dimensions L 100 mm H 112 mm W 17 5 mm Box PBT Black Isolations Standards 1500 V The module complies with the following standards EN61000 6 4 2002 10 electromagnetic emission industrial environment EN61000 6 2 2006 10 electromagnetic immunity industrial environment sce EN61010 1 2001 safety All circuits must be isolated from the other circuits under dangerous voltage with double isolation The ADDITIONAL NOTES power supply transformer must comply with EN60742 Isolated transformers and safety Use in Pollution Degree 2 Environment Power Supply must be Class 2 transformers When supplied by an Isolated Limited Voltage Limited Current power supply a fuse rated max 2 5Ashallbe installed in the field PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 ED1 ENGLISH 3 8 MODBUS CONNECTIONS RULES 1 Connect the module into the DIN rail max 120 2 Use a suitable length
3. sorties num riques ne doivent tre activ es que si la tension d alimentation externe appliqu e aux bornes 1 et 12 est sup rieure 6 Vcc R GLAGE COMMUTATEURS La position des commutateurs d finit les param tres de communication Modbus du module Adresse et Baud Rate Les valeurs du Baud Rate et de l adresse en fonction de la configuration des commutateurs sont report es dans le tableau suivant TAT DES COMMUTATEURS POSITION BAUD RATE POSITION ADRESSE POSITION TERMINATEUR OOxxxxxxxx 9600 xx000001xx 1 XXXXXXXXXO d sactiv 01xXxxxxxxx 19200 xx000010xx 2 XXXXXXXXX1 activ 10xxxxxxxx 38400 LL 11xxxxxxxx 57600 xx111111xx 63 POSITION BAUD RATE POSITION ADRESSE xx000000 From EEprom xx000000 From EEprom Remarque Quand les commutateurs de 3 8 sont sur OFF les param tres de communication sont pris par la programmation EEPROM Remarque 2 La terminaison de la ligne RS485 ne doit tre effectu e qu aux extr mit s de la ligne de communication PYRO CONTROLE FRANCAIS 6 8 694082A00 Ed1 CHAUVIN ARNOUX GROUP REGISTRES MODBUS Holding register Registre Nom Description 40003 OUTPUT L tat des bits de ce registre contr le les sorties Sortie 1 40003 0 Sortie 2 40003 1 Sortie 3 40003 2 Sortie 4 40003 3 Sortie 5 40003 4 Sortie 6 40003 5 Sortie 7 40003 6 Sortie 8 40003 7 Sortie 9 40003 8 Sortie 10 40003 9 Coil registers Registre Nom Description 10001 OUTPUT1 Idem bit 0 d
4. ECTIONS Power supply and Modbus interface From IDC10 rear connector of the module or PDM DINx optional are available power supply and Modbus interface In the next page are shown the use specifications of IDC10 and PDM DINx PYRO Bai CONTROLE 694082A00 Ed1 ENGLISH 4 8 Rear connector IDC10 RS485 GND RS485 A Power Supply AC Power Supply AC In the figure the meaning of the IDC10 connector pins is showed This connector can be used in alternative to the screw terminals blocks RS485 B pee PDM DIN 2 CS Accessory use DIP SWITCH 120 Ohm terminator i If PDM DIN 2 CS accessory is used the power supply signals and communication signals may be provided by the terminals block into the DIN rail support In the figure are shown the meaning and the position of the terminal blocks The DIP switch set the 120 Q terminator not used in Modbus communication GNDSHLD Shield to protect the connection cables recommended ooo000 00000 oooog ooo0o00 i Digital Outputs Z 10 D OUT Z 10 D OUT 3 12 Q 12 OUTPUT gt OUTPUT O gt PYRO mel CONTROLE 694082A00 ED1 ENGLISH 5 8 Warnings e The power supply for these loads MUST be provided directly from terminal 1 maximum 30 Vdc The return currents of the loads MUST be connected together and to the terminal 12 e The total current the sum of the maximum peak currents of all the loads that can enter fro
5. PYRO CONTROLE CHAUVIN ARNOUX GROUP Serie PDM PDM 10DO Module 10 sorties num riques avec protocole Modbus RS485 Manuel d installation Sommaire Caract ristiques g n rales Caract ristiques techniques Connexion au Modbus Installation Branchements lectriques Sorties num riques R glage commutateurs Signalisation l aide de DELS Param tres d usine PYROCONTROLE Groupe Chauvin Arnoux 6bis Av Dr Schweitzer 69881 MEYZIEU Cedex FRANCE Tel 33 0 4 72 14 15 40 Fax 33 0 4 72 14 15 41 Pour les manuels et le logiciel de configuration visiter le site www pyrocontrole com Ce document est la propri t de Pyrocontrole Il est interdit de le copier ou de le reproduire sans autorisation Le contenu de la pr sente documentation correspond aux produits et aux technologies d crites Les donn es report es pourront tre modifi es ou compl t es pour des exigences techniques et ou commerciales PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 Ed1 FRAN AIS 1 8 CARACT RISTIQUES G N RALES 10 sorties MOSFET avec n gatif en commun alimenter entre 30 Vcc et 6 Vcc eCourant maximal sortie num rique 0 5 A charge r sistive et 0 5 A charge inductive avec fr quence maximale de cycle ON OFF de deux cycles la seconde Bornes amovibles section 2 5 mm Sorties prot g es contre le court circuit R glage d un tat de s curit des sorties au d marrage ou en c
6. as d absence de communication e Temps de s curit r glable de 33 ms 2184 s Diagnostic des courts circuits Mesure de la tension d alimentation des charges Possibilit de configuration en ligne Communication s rie RS485 avec protocole Modbus Rtu maximum 64 n uds Isolation 1 500 Vca des sorties par rapport aux circuits basse tension C blage facilit de l alimentation et de la connexion s rie l aide d un bus pouvant tre log dans le rail DIN 46277 Insertion et extraction du bus sans interruption de la communication ou de l alimentation du syst me Temps de communication inf rieurs 10 ms 38400 Baud Distance de branchement jusqu 1 200 m Commutateur pour configurer adresse et vitesse de communication Baud Rate du module CARACT RISTIQUES TECHNIQUES SORTIES Type de sortie MOSFET avec n gatif en commun Courant max sortie num rique 0 5 A charge r sistive Alimentation externe 6 30 Vdc Nombre de canaux 10 Courant max sur le mosfet 0 5 A Tension max sur le mosfet 30 Vdc Energie Max support e l mise on di mosfet 40 mJ avec charge inductive Temps de r ponse du mosfet 5 2 ms PYRO CONTROLE 694082A00 Ed1 FRANGAIS 2 8 CHAUVIN ARNOUX GROUP ALIMENTATION 10 40 Voc 19 28 Vac 50 60 Hz tension typique 1 5 W Max 2 5 W CONDITIONS AMBIANTES Consommation temp rature 10 65 C 10 55 C UL humidit 30 90 a 40 C sans condensation Alti
7. cable to connect the remote modules In the table below the relative data to the length of the bus and length of the cable are reported Bus length Maximum length of the Modbus network The bus length is determined from the length of network that has the two modules who has been switched on the bus terminator see scheme 1 Drop length Maximum length of branch see scheme 1 Bus length Drop Node 3 Node 4 length h T inator Ld erminator 1200 m 2m ee I __Node 1 Node 2 Node 5 Bus Length Scheme 1 Ld Drop Length For the maximum performances it s recommended to use a specific shielded cable INSTALLATION RULES The module is designed to be installed in vertical position on DIN 46277 rail For the best performance and long life cycle the cables raceways and other objects in the control panel must be placed not to obstruct the slits of the module that must be ventilated Never install the modules near heat sources it s advised the installation of the module in the lower part of the control panel Inserting on the DIN rail Inserting in the DIN rail Module As itis illustrated in the next figure 1 Insert the module IDC10 rear connector on the DIN rail free slot the inserting is unequivocal because the connectors are polarized 2 The module can be fixed on the DIN rail through the clench of the two hooks in the lower part of it orere DIN rail s ELECTRICAL CONN
8. la DEL fail dans le registre modbus pertinent Possibilit de r gler un timer qui indique au bout de combien de temps la sortie est reconnue en court circuit Possibilit de pr voir un timer de s curit qui r gle au bout de combien de temps les sorties sont configur es dans un tat de s curit pr d fini Possibilit de r gler l tat de s curit des sorties qui sera utilis en cas d absence de communication pendant un temps gal celui r gl dans le timer de s curit Pour toute modification des param tres le logiciel PDM Studio est disponible dans la zone t l chargement du site Web www pyrocontrole com Pour de plus amples informations sur la liste des registres et leurs fonctions consulter le Manuel d Utilisation G n ral S rie PDM limination des d chets lectriques et lectroniques applicable dans l Union europ enne et dans les autres pays qui pratiquent la collecte s lective Le symbole report sur le produit ou sur l emballage indique que le produit ne ps doit pas tre jet avec les ordures m nag res Il doit au contraire tre remis une station de collecte s lective autoris e pour le recyclage des d chets lectriques et lectroniques Le fait de veiller ce que le produit soit limin de fa on ad quate permet d viter l impact n gatif potentiel sur l environnement et la sant humaine pouvant tre d l limination non conforme de ce dernier Les recyclage des mat
9. m terminal 1 MUST BE LIMITED TO 5 A with quick break fuse or equivalent protection e In order to obtain recognition of the output short circuit the power supply to the loads must withstand the short circuit current without permitting the voltage to fall below 6 V e The digital outputs can be activated only for a external voltage supply higher than 6 V in the screw terminals 1 and 12 DIP SWITCHES SETTING The DIP switches positions defines the Modbus communication parameter Address and Baud rate In the following table the Baud rate and address value are listed as a function of the DIP switches position DIP switches table POSITION BAUD RATE POSITION ADDRESS POSITION TERMINATOR 00xxxxxxxx 9600 01xxxxxxxx 19200 10Xxxxxxxx 38400 1100000007 57600 xx000001xx 1 xx000010xx 2 XXXXXXXXX0 Disable XXXXXXXXX1 Enable xx111111xx 63 POSITION BAUD RATE POSITION ADDRESS xx000000 From EEprom xx000000 From EEprom Note when DIP switches from 3 to 8 are in OFF communication settings are retrieved from EEprom Note 2 The termination of RS485 communication must be enabled only to the ends of the communication line PYRO CONTROLE ENGLISH 6 8 694082A00 Ed1 MODBUS BASIC REGISTER AND LED SIGNALLINGS Holding register Register Name Description 40003 OUTPUT Set the bit in the register to control the relative output Output 1 40003 0 Output 2 40003 1 Output 3 40003 2 Output 4 40003 3 Output 5 40003 4 Out
10. ollectively connected to an external supply with maximum 30 Vdc and minimum 6 Vdc e Digital output carrying capacity 0 5 A inductive load and 0 5 A resistive load with maximum switch on switch off cycle frequency of 2 cycles second e Removable terminals with section of 2 5 mm e Outputs protected against short circuit e Outputs safety status setting at power on and in case of lost communication e Safety time can be set from 33 ms to 2184 s e Diagnostic for short circuits Measurement of the load power supply voltage e Possibility of ON LINE configuration e RS485 serial communication with Modbus Rtu protocol maximum 64 nodes e 1500 Vac output isolation compared with other low voltage circuits e Easy connections for power supply and serial communication from PDM DIN bus system for standards DIN 46277 rail e Module insertion or extraction from PDM DIN bus without interruptions for communication and power supply e Communication time below 10 ms 38400 Baud e Connection distance up to 1200 m e Set the Modbus address and the Baud rate with DIP Switch TECHNICAL SPECIFICATIONS Outputs Type output MOSFET with shared negative pole Digital output carrying capacity 0 5 A resistive load External power supply 30 Vdc Number of channel 10 Maximum rated current of 05A Mosfet Maximum rated voltage of 30 VDC Mosfet Maximum output clamp energy 49 my with inductive load capability Time delay mosfet 5 2
11. ont disponibles en utilisant le bus pour rail DIN l aide du connecteur arri re IDC10 et des accessoires PDM DIN PYRO CONTROLE 694082A00 Ed1 FRAN AIS 4 8 CHAUVIN ARNOUX GROUP Connecteur arri re IDC 10 RS485 GND RS485 A Power Supply AC Pr sentation des connexions du bornier IDC10 pour une utilisation externe Power Supply AC RS485 B IDC 10 Accessoire PDM DIN C 2S 2 DIP SWITCH En cas d utilisation des accessoires Power supply AC Power supply AC p PDM DIN Ex PDM DIN C 2S l alimentation et le Rs485 peuvent tre connect s sur les borniers Cf ci contre 120 Ohm terminator i l oo 00 oo oo oo GNDSHLD Blindage pour prot ger les cables de connexion conseill Z 10 D OUT 1 OUTPUT gt gt OUTPUT gt gt PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 Ed1 FRAN AIS 5 8 Attention eL alimentation pour ces charges DOIT tre fournie directement par la borne 1 maximum 30 Vcc Les retours des charges DOIVENT tre connect s les uns aux autres et la borne 12 e Le courant global pouvant entrer par la borne 1 somme des courants de pointe de chaque charge DOIT ETRE LIMIT E 5A avec un fusible rapide ou une protection quivalente e Pour d tecter les courts circuits la sortie l alimentation des charges doit supporter le courant de court circuit sans que la tension ne descende en dessous de 6 V e Les
12. orte les donn es relatives la longueur des c bles Longueur bus longueur maximale du r seau Modbus en fonction de la vitesse de transmission Baud Rate C est la longueur des c bles qui relient les deux modules sur lesquels est ins r e la terminaison du bus voir Sch ma 1 Longueur d rivation longueur maximale d une d rivation 2 m voir Sch ma 1 n ud 3 H n ud n ud n ud fe Longueur bus Longueur 2 TE d rivation S i T 1200m 2m RE P 1 CO Je Sch ma 1 Longueur bus Pour obtenir le maximum de performances il est conseill d utiliser des c bles blind s INSTALLATION Le module a t con u pour tre mont a la verticale sur un rail DIN 46277 Pour que l instrument fonctionne correctement s assurer que la ventilation est ad quate en veillant a ce qu aucun chemin de c ble ou autre objet ne bouche les fentes d a ration viter de monter les modules sur des appareils qui d gagent de la chaleur il est conseill de les monter en bas de l armoire Insertion dans le guide DIN module Commeillustr sur la figure 1 Ins rer le connecteur arri re IDC10 du module sur un slot libre du rail DIN les connecteurs sont polaris s 2 Pour fixer le module dans le rail DIN serrer les deux clips situ s de chaque c t du connecteur arri re IDC10 355 Rai El DIN BRANCHEMENTS LECTRIQUES ALIMENTATION ET INTERFACE MODBUS L alimentation et l interface Modbus s
13. put 6 40003 5 Output 7 40003 6 Output 8 40003 7 Output 9 40003 8 Output 10 40003 9 Coil registers Registers Name Description 10001 OUTPUT1 as bit 0 of register 40003 10002 OUTPUT2 as bit 1 of register 40003 10003 OUTPUT3 as bit 2 of register 40003 10004 OUTPUT4 as bit 3 of register 40003 10005 OUTPUT5 as bit 4 of register 40003 10006 OUTPUT6 as bit 5 of register 40003 10007 OUTPUT7 as bit 6 of register 40003 10008 OUTPUTS as bit 7 of register 40003 10009 OUTPUT9 as bit 8 of register 40003 10010 OUTPUT10 as bit 9 of register 40003 LEDs signaling LED STATE Meaning of LEDs PWR On Power supply presence FAIL Blinking See advanced settings RX Blinking Received data On Error connection TX Blinking Received data PYRO Bed CONTROLE 694082A00 ED1 ENGLISH 7 8 FACTORY SETTING AND ADVANCED SETTING Factory settings All DIP switch in OFF position Modbus protocol Communication parameters 38400 8 N 1 Addr 1 Digital Outputs NORMAL OPEN Safety state ENABLE Safety timer DISABLE Reversal of status relay DISABLE Delay short circuit recognition up to 1s Control supply voltage output ENABLE Advanced settings e Constant control of the outputs short circuit with a settable diagnostic modbus register e Control the outputs short circuit with a settable timer in the modbus register e Control and set the blinking of fail LED with a settable modbus register e Set a timer to regulate the time after that the ou
14. tput will be set in the short circuit state Seta safety timer to regulate the time that the outputs will be setin the safety state Set the outputs safety state that will be enabled in case of lost communication for a time equal to set safety timer Modification of standard parameters is possible by using configuration software PDM Studio www pyrocontrole com For more information about a list of all registers and their functions consult the PDM General User manual Disposal of Electrical amp Electronic Equipment Applicable throughout the European Union and other European countries with separate collections programs This symbol found on your producr or on its packaging indicates ps that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical amp electronic equipment By ensuring this product is didposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of the product please contact your local city office waste disposal service of the retail store where you purchased this product PYRO CONTROLE 694082A00 Ed1 ENGLISH 8 8 CHAUVIN ARNOUX GROUP
15. tude jusqu 2 000 m au dessus du niveau de la mer Temp rature de 7 stockage 20 85 C Indice de protection IP20 CONNEXIONS Bornes a vis amovibles a 3 voies pas 5 08 mm connexions Connecteur arri re IDC10 pour rail DIN 46277 ENCOMBREMENTS BOITIER dimensions Largeur 100 mm hauteur 112 mm profondeur 17 5 mm Boitier PBT Couleur noir ISOLATIONS NORMES 1500 V L instrument est conforme aux normes suivantes EN61000 6 4 2002 10 mission lectromagn tique milieu industriel EN61000 6 2 2006 10 immunit lectromagn tique milieu industriel EN61010 1 2001 s curit Tous les circuits doivent tre isol s avec une double isolation des circuits sous tension dangereuse Le transformateur d alimentation doit satisfaire la norme EN60742 Transformateurs d isolation et transformateurs de s curit REMARQUES SUPPL MENTAIRES SUR L UTILISATION utiliser dans des milieux avec degr de pollution 2 Le dispositif d alimentation doit tre de classe 2 S il n est pas aliment par un dispositif d alimentation isol limit e en tension limit e en courant il convient de prot ger la ligne par un fusible de 2 5 A max PYRO CONTROLE CHAUVIN ARNOUX GROUP 694082A00 Ed1 FRAN AIS 3 8 CONNEXION AU MODBUS 1 Installer les modules dans le rail DIN max 120 2 Brancher les modules distance en utilisant des c bles ayant une longueur appropri e Le tableau ci dessous rep
16. u registre 40003 10002 OUTPUT2 Idem bit 1 du registre 40003 10003 OUTPUT3 Idem bit 2 du registre 40003 10004 OUTPUT4 Idem bit 3 du registre 40003 10005 OUTPUT5 Idem bit 4 du registre 40003 10006 OUTPUT6 Idem bit 5 du registre 40003 10007 OUTPUT7 Idem bit 6 du registre 40003 10008 OUTPUT8 Idem bit 7 du registre 40003 10009 OUTPUT9 Idem bit 8 du registre 40003 10010 OUTPUT10 Idem bit 9 du registre 40003 SIGNALISATION A L AIDE DE DELS LED ETAT SIGNIFICATION DES DELS PWR Fixe Le dispositif est aliment correctement FAIL Clignote voir param tres avanc s RX Clignote r ception paquet de donn es Fixe v rification connexion TX Clignote transmission paquet de donn es PYRO Bed CONTROLE 694082A00 Ed1 FRANCAIS 7 8 PARAMETRES D USINE PARAMETRES AVANCES PARAMETRES D USINE Tous les commutateurs sur OFF Protocole Modbus Param tres de communication 38400 8 N 1 Addr 1 Sorties num riques NORMALEMENT OUVERTES tat de s curit ACTIV Temps de s curit D SACTIV Inversion tat relais D SACTIV Retard reconnaissance court circuit jusqu 1 s Contr le tension d alimentation sorties ACTIV PARAMETRES AVANCES Possibilit de contr ler constamment le court circuit des sorties apr s configuration du registre de diagnostic Possibilit de g rer le court circuit avec un timer pouvant tre r gl l aide du registre modbus Possibilit de r gler le mode de clignotement de

Download Pdf Manuals

image

Related Search

Related Contents

Nilfisk-ALTO IP32 7EA User's Manual  Manual - Rays Aviation  EVOLUTION - DiscreetFX  CheckPoint User Manual & Training Guide  Customer Report User Guide  Mode d`emploi - BLUESTAR Forensic    Tricity Bendix BS 615 SO Oven User Manual  NOTICE POUR LE PUBLIC BICLAR DENOMINATION  Crosley 134856500 Clothes Dryer User Manual  