Home
DEQ-230 Digitaler Parametrischer/Grafischer Equalizer
Contents
1. XX O 31 ID device Npreset 0 31 Presetnumber The DEQ 230 s microcontroller will check if the Preset is initialized available or not yet created B If YES then the microcontroller will send back to the User e g Crestron AMX Remote Control the same frame used by the command RX STX ID_M ID_N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 1BH NPreset 00H 00H 00H 00H 00H 00H 00H F7H So in this case if the user gets back EXACTLY what was sent the preset is existing and loaded on the unit C If the preset that the user wanted to load is NOT YET INITIALIZED not yet created so not available The microcontroller will notify that to the user sending back the following frame RX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH CIH XX 1BH FFH 00H 00H 00H 00H 00H 00H 00H F7H Input Gain and Output Volume Control UPDATE GAINS PHASE CMD 01H A The User has to send the following Command including the value to be assigned to Vol for modifying the Input Gain Chn O 1 or the Output Volume Chn 2 3 Also the Output signal Phase can be modified TX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 01H Chn 00H 00H 00H 00H 00H Phs Vol F7H XX O 31 ID device Chn 0 3 Channel selected 0 1 Ini1
2. Release Time R Der ausw hlbare Bereich der R ckstellzeit des Limiters betr gt 0 1 s bis 3 s in Schritten von 0 1 s und l sst sich mit dem Drehknopf PM2 einstellen Limiter Active Threshold Der ausw hlbare Bereich des Schwellwertes des Limiters betr gt 20 dB Limiter nicht aktiv bis 10 0 dB in Schritten von 0 2 dB und l sst sich mit dem Drehknopf PM3 einstellen Anmerkung 1 Sobald die gew nschten Optionen mit den 3 Drehkn pfen ausgew hlt werden werden sie nach Verlassen der Seite automatisch als aktuelle Werte im Systemstatus des DEQ 230 gespeichert Anmerkung 2 Zum Verlassen dieser Seite die Taste ESC bet tigen Anmerkung 3 Die LED Anzeigen ber den Tasten LCOMP und RCOMP zeigen die Aktivit t des Limiters Sie zeigen die Begrenzung des Ausgangssignals in dBu von oben nach unten 26 e MENU A B Output Channels Utilities Zugang uber die Tasten LOUT ROUT Vom Startbildschirm aus gelangt man durch Bet tigung der Taste LOUT bzw ROUT in das Men Equalizer s Channel Utilities Sobald die Taste gedr ckt wird leuchtet die entsprechende blaue LED EDIT Die Untermen Seiten lassen sich durch Drehen des Drehknopfs NAV PAR1 im Uhrzeigersinn bzw entgegen dem Uhrzeigersinn durchlaufen Die verf gbaren Optionen sind folgende 1 Flat Equalizer 2 Copy Equalizer from Ch x 3 Set Eq as graphic mode Das bisherige Programm kann mit der Taste ENTER best tigt werden Nach der Aufforderung zur B
3. PM2 and PM3 encoders Please refer to the following menu structures 34 MENU UTILITY MENU Access by pushing the UTILITY button NAV PAR1 Encoder to navigate between menus 1 UTILITY MENU lt lt System Utilities gt gt exren fesc 1 1 SYSTEM UTILITY lt lt Delay Units gt gt 1 2 SYSTEM UTILITY lt lt Ramps on changes gt gt 1 3 SYSTEM UTILITY lt lt Software Version gt gt 2 UTILITY MENU lt lt Program Utilities gt gt enter f Esc 2 1 PROGRAM UTILITY lt lt Recalla Program gt gt 2 2 PROGRAM UTILITY lt lt Savea Program gt gt 2 3 PROGRAM UTILITY lt lt Delete a Program gt gt 3 UTILITY MENU lt lt Interface Utilities gt gt enter tesc 3 1 INTERFACE UTILITY Interface Setup lt lt Security Utilities gt gt ener ESS 4 1 SECURITY UTILITY Show Parameter 4 2 SECURITY UTILITY Lock Unit 4 3 SECURITY UTILITY User Password 4 4 SECURITY UTILITY Enable Password Enter i ENTI j s un IE x LA pan r ENTER PM2 or PM3 Encoder to chose option then ENTER to load it indicates the selected option Delay Units Unit Time ms Unit Distance m Ramps on changes Ramps Off Ramps On Software Version Version V1 01 Recall a Program 01 Default Flat 02 Default Classic 03 Default Disco 04 Default Jazz 05 Default Pop 06 Default RnB 07 Default Rock 0
4. So in order to define the filter type for the filter number 1 x 1 it is necessary from the above screen to enter the filter s editing page pressing the ENTER button and the screen has to appear as follows In this case the filter s GAIN 0 0dB and being BW 1 05 the current filter selected is a Bell type Now rotating the PM2 encoder clockwise the parameter BW will range from 0 05 up to 3 for identifying a bandwidth value for a Bell filter If a Bell filter is selected then the Gain can be modified from 0 0dB and the BW will range between 0 05 and 3 If the user wants to select a Shelving filter from the above setting with the GAIN 0 0dB if the GAIN is not 0 0dB it is necessary to set it at 0 0dB using the PM3 encoder rotate the PM2 counter clockwise Once BW reaches the 0 05 value at the next step of the PM2 counter clockwise rotation the selection of the Shelving filters will be entered Still rotating the PM2 counter clockwise the Shelving filters and their order will be selectable in the following sequence 1 order Low Shelving 6LoSh on the screen 2 order Low Shelving 12LoSh on the screen 1 order High Shelving 6HiSh on the screen 2 order High Shelving 12HiSh on the screen ee ae ee Once the desired Shelving filter is selected the PM3 can then be used to select the desired GAIN and when the GAIN is set at a value different from 0 0dB then the filter type cannot be changed until this
5. Channel selected 0 1 Ini In2 2 3 Out1 Out2 when Channel O 1 selected then Vol Input Gain when Channel 2 3 selected then Vol Output Vol Phs Phase only if the Chn gt 1 Value 0 1 where O direct 1 inverse 180 Vol Gains from O to 180 12dB 6dB step 0 1dB B Wenn der Befehl korrekt ausgef hrt und die Verst rkung Lautst rke ge ndert wurde dann schickt der Mikrocontroller dem Benutzer z B Crestron AMX Remote Control den im Befehl verwendeten Rahmen zur ck RX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 01H Chn 00H 00H 00H 00H 00H Phs Vol F7H 31 e Technische Daten des DEQ 230 Der digitale Equalizer DEQ 230 basiert auf einer leistungsstarken analogen und digitalen DSP Plattform mit den folgenden technischen Daten Analoges Eingangssignal LIN RIN XLR Buchse sym Maximaler Eingangspegel 20 dBu Analoges Ausgangssignal LOUT ROUT XLR Stecker sym Maximaler Ausgangspegel 20 dBu Digitalverarbeitung DSP SAM3716 24 Bit Daten x 96 Bit Koeffizienten A D Wandler aussen AKM5392 24 Bit D A Wandler zuussssnnnnne nenn nenn AKM4396 24 Bit Abtastfrequenz cccccceeseeeeeeeeees 48 kHz S PDIF Stereo Digitaleingang geeignete Signalquellen 32 kHz 44 1 kHz und 48 kHz Rauschabstand cceeeeeeee eens 110 dBA Klirrfaktor Niv scssseeeeeeeueeeueeeea
6. Enter bet tigen 2 Output x Name Set Eq as graphic mode tes Zur Bestatigung Enter betatigen 3 Output x Name Flat Equalizer enter f Esc Zur Best tigung Enter bet tigen Drehknopf NAV PAR1 Drehknopf PM2 Drehknopf PM3 zum Ausw hlen von Werten f r die Parameter die Werte brauchen nicht best tigt zu werden sie werden w hrend der Bet tigung der Drehkn pfe automatisch geladen y ist nicht der aktuell gew hlte Kanal wenn X A ist dann ist y b PAR1 N A PAR1 N A PAR1 N A Nach Bet tigung der Taste ENTER wird Kanal y auf Kanal x kopiert PAR1 N A PAR1 N A PAR1 N A Nach Bet tigung der Taste ENTER wird der Equalizer auf Graphic Eq eingestellt wobei die 30 Mittenfrequenzen automatisch im Abstand von 1 3 Oktave eingestellt werden PAR1 N A PAR1 N A PAR1 N A Nach Bet tigung der Taste ENTER wird der Equalizer zur ckgesetzt und die Verst rkung aller Filter auf O dB zur ckgestellt e Men UTILITY Zugang ber die Taste UTILITY Vom Startbildschirm aus gelangt man durch Betatigung der Taste UTILITY in das Menu UTILITY Zum Ausw hlen der Untermen Seiten den Drehknopf NAV PAR1 im Uhrzeigersinn bzw entgegen dem Uhrzeigersinn drehen Durch Bet tigung der Taste ENTER gelangt man auf die Untermen Seiten Den Drehknopf NAV PAR1 erneut bet tigen und die Parameter mit der Taste ENTER best tigen ber die Taste ESC ist es jederzeit m glich zu dem Vorgang oder
7. In2 2 3 Out1 Out2 when Channel O 1 selected then Vol Input Gain when Channel 2 3 selected then Vol Output Vol Phs Phase only if the Chn gt 1 Value 0 1 where O direct 1 inverse 180 Vol Gains from O to 180 12dB 6dB step 0 1dB B If the command has been properly executed and the Gain Volume modified then the microcontroller will send back to the User e g Crestron AMX Remote Control the same frame used by the command RX STX ID M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 01H Chn 00H 00H 00H 00H 00H Phs Vol F7H 60 e DEQ 230 Technical Specifications The DEQ 230 Digital Equalizer is based on a powerful analog and digital DSP platform having the following specifications Analog Input Signal LIN RIN Bal Female XLR Maximum Input Level 20dBu Analog Output Signal LOUT ROUT Bal Male XLR Maximum Output Level 20dBu Digital Processing DSP SAM3716 24bits data x 96 bits coeff A D Converters ccceceeceveeceveueas AKM5392 24bits D A Converters ccccceeceeeeceveeees AKM4396 24bits Sampling Frequency 08 48kHz S PDIF Stereo Digital Input 32kHz 44 1kHz and 48kHz Sources Accepted ANE AAE 110dBA TAO EN Gear 0 005 Frequency Response Bypass 20Hz 20kHz 1 dB Power Supply ccceeeeeeeen eens Switching Power Supply Remote Co
8. Wenn die Verst rkung auf einen anderen Wert als 0 0 dB eingestellt wird l sst sich der Filtertyp solange nicht ndern bis die Verst rkung wieder auf 0 0 dB zur ckgestellt wird In der Bearbeitungsmaske f r das Tiefenfilter mit Kuhschwanzcharakteristik lassen sich mit den Drehkn pfen NAV PAR1 PM2 und PM3 alle Parameter des Filters zum Einstellen der oberen Grenzfrequenz Filterordnung und Verst rkung modifizieren Die obere Grenzfrequenz des Tiefenfilters mit Kuhschwanzcharakteristik l sst sich mit dem Drehknopf NAV PAR1 einstellen die Ordnung mit dem Drehknopf PM2 und die Verst rkung mit dem Drehknopf PM3 Hi Cut Frequency Der ausw hlbare Frequenzbereich betr gt 20 Hz bis 20 kHz in Schritten von einer 1 24 Oktave und l sst sich mit dem Drehknopf NAV PAR1 einstellen Low Shelving Order Der ausw hlbare Bereich des Tiefenfilters mit Kuhschwanzcharakteristik umfasst 1 Ordnung Lo 1st und 2 Ordnung Lo 2nd Gain Die ausw hlbare Verst rkung betr gt 15 dB bis 15 dB in Schritten von 0 5 dB und l sst sich mit dem Drehknopf PM3 einstellen 24 High Shelving Filter Beispiel Wenn ein H henfilter mit Kuhschwanzcharakteristik innerhalb des EQ 1 eingestellt werden soll muss der Drehknopf PM2 entgegen dem Uhrzeigersinn gedreht werden bis das gew nschte H henfilter mit Kuhschwanzcharakteristik z B 6HiSh auf dem Bildschirm erscheint die Verst rkung z B 3 0 dB mit dem Drehknopf PM2 einstellen und
9. nge des 3 Equalizers stummzuschalten MUTE Mit den Tasten LOUT ROUT und LCOMP RCOMP erhalt der Benutzer Zugriff auf die Programm Funktionen des Equalizers LOUT ROUT oder Zugang zu den Einstellmen s f r den Kompressionsbereich des Equalizers LCOMP RCOMP Mit den BYPASS Funktionen wird die Equalizer Einstellung LOUT ROUT bzw die Kompressor Einstellung LCOMP RCOMP umgangen Die Tasten LIN RIN sowie die Tasten LOUT ROUT und LCOMP RCOMP haben eine Doppelfunktion die von der Bet tigungsdauer abh ngt Wenn die Tasten LIN RIN gedr ckt und l nger als eine Sekunde gedr ckt gehalten werden wird die Stummschaltung der Eingangskan le LIN oder RIN aktiviert bzw deaktiviert Die rote LED leuchtet auf wenn der Kanal stummgeschaltet wurde Wenn die LED MUTE nicht leuchtet dann wurde die Stummschaltung des betreffenden Eingangskanals deaktiviert UN MUTED Durch eine kurze Bet tigung der Tasten LIN RIN gelangt man in den Einstellmodus f r die Kan le des Equalizers weitere Einzelheiten zur Kanaleinstellung des Equalizers folgen Die blaue LED EDIT leuchtet Wenn die Tasten LOUT ROUT gedr ckt und l nger als eine Sekunde gedr ckt gehalten werden wird die Equalizer Einstellung entweder umgangen bypassed und die Einstellungen des Equalizers werden zur ckgesetzt oder der Equalizer f hrt die aktuelle Einstellung aus Die rote LED leuchtet wenn die Einstellungen des Equalizers zur ckgesetzt wurden Wenn d
10. Equalizer Kan le LIN RIN und Kompressor Limiter Kanale LCOMP RCOMP Nach der Einstellung der Parameter f r die einzelnen Equalizer Kan le bzw Kompressor Kan le merkt sich der DEQ 230 den letzten Einstellvorgang auf diesem Kanal Wenn beim n chsten Einstellvorgang auf diesem Kanal die Taste EDIT bet tigt wird kehrt man unverz glich zur entsprechenden Bildschirmmaske des letzten Einstellvorgangs zur ck Diese Funktion erleichtert die Feineinstellung oder Modifizierung wenn eine Reihe von Einstellungen desselben Parameters innerhalb kurzer Zeit vorgenommen werden m ssen e Verbindungsmodus LINK f r die Equalizer Kan le und Kompressor Limiter Kan le Der DEQ 230 ist in der Lage eine Verbindung zwischen den Equalizer Kan len sowie eine Verbindung zwischen den Kompressor Kan len herzustellen um eine schnelle und unmittelbare Einstellung zu erm glichen die Kan le des Equalizers lassen sich nicht mit den Kan len des Kompressors verbinden Um Kan le bei der Einstellung zu verbinden einen Master Kanal ausw hlen der eingestellt und auf dem LCD Bildschirm dargestellt werden soll Dann die anderen Kan le Slave Kan le die man in der gleichen Weise ndern m chte ausw hlen und verbinden Um in den Verbindungsmodus zu gelangen den Einstellmodus f r den Master Kanal ausw hlen dann die entsprechenden EDIT Tasten bet tigen um die Slave Kan le zu verbinden Sobald eine Verbindung besteht sind die ausgew hlten K
11. Equalizer s Channel Analog InA Input Channel A Analog InB Input Channel B Analog InA B Sum of Input Channel A 2 Input Channel B 2 Digital Left Input S PDIF Channel Left Digital Right Input S PDIF Channel Right Digital L R Sum of Input S PDIF Channel Left 2 Input S PDIF Channel Right 2 nt The following is an example screen for the Source where Analog Input A is assigned to Equalizer s Channel A named Left After pressing ENTER an arrow will appear on the left of the screen gt the Input can be selected by rotating either the PM2 or PM3 encoders Gain page from this screen it is possible to set the Equalizer s Channels Level from 15dB to 15dB press ENTER an arrow will appear on the left of the screen gt then use the PM1 or PM2 buttons The value set on this screen will only affect the input level of the selected Equalizer s Channel LIN RIN The following is an example screen for the Gain page where the Gain of the Equalizer s Channel A named Left is set to 0 0dB Polarity page from this page it is possible to set the Equalizer s Channel Polarity by using the PM1 or PM2 encoders The polarity can be Normal or Inverted which means rotated of 180 Degrees The following is an example of a Polarity screen where the Polarity of the Equalizer s Channel A named Left is set to Normal 50 Delay page from t
12. GAIN is returned to 0 0dB 53 BELL Filter As an example if we want to set a bell filter within EQ 1 then the BW has to be set at a desired value of say 1 00 using the PM2 encoder the GAIN at say 3dB using the PM3 encoder and the center Frequency at say 1 00KHz with the NAV PAR1 encoder The EQ sub menu screen will show the following Once in the Bell Filter s edit screen all the filter s parameters can be modified using the NAV PAR1 PM2 and PM3 encoders for editing the Filter s Center Frequency Bandwidth BW and Gain The Center Frequency of the Parametric Filter can be edited using the NAV PAR1 encoder the BW the PM2 encoder and the Gain the PM3 encoder Center Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1 24 of an Octave and can be adjusted by rotating the NAV PAR1 encoder Bandwidth BW the selectable BW range is from 0 05 Octave to 3 Octave in steps of 0 05 Octave and can be adjusted by rotating the PM2 encoder Gain the selectable Gain range is from 15dB to 15dB in steps of 0 5 dB and can be adjusted by rotating the PM3 encoder Low Shelving Filter As an example if we want to set a low shelving filter within EQ 1 then the PM2 encoder has to be rotated counter clockwise until the desired Low Shelving filter say 6LoSh appears on the screen the GAIN at say 3 0dB using the PM3 encoder and the High Cut Frequency at say 1
13. PARI N A Normal Same as PAR2 Invert 6 Output x Name Delay Delay 0 000 ms enter f Esc gt Delay 0 000 ms PAR1 N A 000 0000mS 000 0000mS 1 ms steps 20 8 us steps 848 0000mS 000 9984mS 7 Output x Name HPF 20 0 Hz No Cut Off ENTER tesc gt 20 0 Hz No Cut Off PAR1 N A Freq 20Hz Type Slope No Cut Off 20kHz Bessel 24dB Oct 8 Output x Name LPF 20 0 Hz No Cut Off ENTER S tesc gt 20 0 Hz No Cut Off PAR1 N A Freq 20Hz Type Slope No Cut Off 20kHz Bessel 24dB Oct 36 9 Output x Name PEQ SHV 1 30 1 00kHz BW SHV_Slope 1 00 up to 12dB 0 0dB ENTER t ESC If through the PM2 being the filter s gain 0 0dB 9 1 9 2 9 3 has been selected a Bell filter just defining its Bandwidth BW to be greater then 0 then the Bell filters can be set by the following parameters Output x Name EQ X up to 30 filters available gt 1 00kHz BW 1 00 0 0dB If through the PM2 being the filter s gain 0 0dB has been selected a Low Shelving filter just defining its Slope 1 or 2 order available 6dB or 12dB then the Low Shelving filter can be set by the following parameters Output x Name EQ X up to 30 filters available gt 1 00kHz 6 12 LoSh 0 0dB If through the PM2 being the filter s gain 0 0dB has been selected a High Shelving filter just defining its Slope 1 or 2 order available 6dB or 12dB then the High Shelving filter can be set by the following paramete
14. PM3 Enc to chose values for the parameters no need to confirm the chosen values which are automatically loaded during the encoders use y is the not currently selected channel so if X A then y b PAR1 N A PAR1 N A PAR1 N A If pushed ENTER the channel y will be copied on the channel x PAR1 N A PAR1 N A PAR1 N A If pushed ENTER the Eq will be set as Graphic Eq where the 30 Center frequencies are automatically set by steps of 1 3 of Octave PAR1 N A PAR1 N A PAR1 N A If pushed ENTER the Eq will be reset taking to OdB the all filters Gain 38 e Menu UTILITY access by pushing the UTILITY button From the Default Screen it is possible access the UTILITY menu pushing the UTILITY button and the Sub Menus pages can be selected just rotating clockwise and counter clockwise the NAV PAR1 encoder Once selected the sub menu page using the ENTER button can be accessed the Sub Menus pages again scrollable using the NAV PAR1 encoder and accessible for the parameters editing pushing again the ENTER button Through the ESC button it is any time possible to go back to the action and page preceding the ENTER button use Once inside the Sub Menus pages the several options can be scrolled and using the PM2 or PM3 encoders and selected confirmed pushing the ENTER button Note In every Sub Menu the option currently selected running will
15. Program Diese Seite erm glicht das Laden eines voreingestellten Programms Der DEQ 230 enth lt bereits 8 Werkseinstellungen welche die ersten 8 Positionen der Voreinstellungsliste belegen die sich im Anhang A Appendix befindet Die 8 Voreinstellungen sind 1 Default Flat Default Classic Default Disco Default Jazz Default pop Default RnB Default Rock Default Vocal CON OU PWN Im Speicher des DEQ 230 lassen sich bis zu 24 Voreinstellungen von Speicherplatz 09 bis Speicherplatz 32 abspeichern Uber die Seite Recall a Program lassen sich die Werkseinstellungen und die verf gbaren Benutzervoreinstellungen fur die Filter des DEQ 230 aufrufen Durch Betatigung der Taste ENTER und des Drehknopfs PM2 bzw PM3 lassen sich alle aktuell verfugbaren Werkseinstellungen und Benutzervoreinstellungen durchlaufen Falls noch keine Benutzervoreinstellungen gespeichert wurden werden lediglich die Werkseinstellungen angezeigt Falls bereits Voreinstellungen vom Benutzer gespeichert wurden lassen sich diese ab Speicherplatz 09 aufrufen 11 Durch Betatigung des Drehknopfs PM2 bzw PM3 lassen sich die zuvor gespeicherten Voreinstellungen durchlaufen Wenn die gew nschte Voreinstellung angezeigt wird diese mit der Taste ENTER ausw hlen Der DEQ 230 l dt die gew hlte Voreinstellung Die folgende bergangsmaske erscheint Nach dem Laden geht der DEQ 230 automatisch zur Bildschirmmaske Recall a Pr
16. and PM3 encoders and the current shown value of the selected option is AUTOMATICALLY loaded during the encoders use and stored as the current value once leaving the page Equalizer s Audio Signal Channels LIN RIN Path Block Scheme S PDIF Left S POIF Right LIN Input RIN Input Name page from this screen it is possible to assign a 6 character name to the Equalizer s Channel The following is an example screen for a Name page labeled Left for the Equalizer s Channel LIN A To Edit press ENTER on the Name Page and the entering arrow will appear as in the example below The first letter position will be blinking Select the Character position from the 6 available by rotating the NAV PAR1 encoder then by using the PM2 or PM3 encoder it is possible to select the desired character Once you are happy with your name selection press ENTER to confirm the edited Name The new name will be stored The following example shows Ch A replacing our previous name of Left 49 NGate page from this screen it is possible to make the available Noise Gate Active To Edit press ENTER on the NGate Page and the entering arrow will appear as in the example below Noise Gate On The Noise Gate s parameters Attack Release times and Threshold can be edited and set by Pc Sw Source page from this page it is possible to assign one of the following Inputs to any
17. ausgew hlt werden werden sie nach Verlassen der Seite automatisch als aktuelle Werte im Systemstatus des DEQ 230 gespeichert Anmerkung 2 Zum Verlassen dieser Seite die Taste ESC bet tigen Hochpassfilter umgangen Butterworth Filter mit einer Flankensteilheit von 6 dB Oktave Butterworth Filter mit einer Flankensteilheit von 12 dB Oktave Linkwitz Riley Filter mit einer Flankensteilheit von 12 dB Oktave Bessel Filter mit einer Flankensteilheit von 12 dB Oktave Butterworth Filter mit einer Flankensteilheit von 18 dB Oktave Butterworth Filter mit einer Flankensteilheit von 24 dB Oktave Linkwitz Riley Filter mit einer Flankensteilheit von 24 dB Oktave Bessel Filter mit einer Flankensteilheit von 24 dB Oktave Untermen LPF Dieses Untermen erm glicht die Einstellung der Tiefpassfilter LPF f r die Equalizer Kanale Das Beispiel unten zeigt die Untermen Bildschirmmaske f r das Tiefpassfilter in der das Filter f r den Equalizer Kanal A mit der Bezeichnung Left auf 24 dB Linkwitz Riley eingestellt wurde LPF 24 Die Filterparameter lassen sich mit den Drehkn pfen PM2 und PM3 zum Einstellen der oberen Grenzfrequenz des Filters sowie des Filtertyps und der Filterordnung modifizieren Die obere Grenzfrequenz des Tiefpassfilters l sst sich mit dem Drehknopf PM2 einstellen der Filtertyp und die Filterordnung mit dem Drehknopf PM3 High Cut Frequency der ausw hlbare Frequenzbereich betr gt 20 Hz bis
18. die Taste UTILITY Drehknopf NAV PAR1 zum Navigieren durch die Ments 1 UTILITY MENU lt lt System Utilities gt gt ENTERS tesc 1 1 SYSTEM UTILITY lt lt Delay Units gt gt 1 2 SYSTEM UTILITY lt lt Ramps on changes gt gt 1 3 SYSTEM UTILITY lt lt Software Version gt gt 2 UTILITY MENU lt lt Program Utilities gt gt enter f esc 2 1 PROGRAM UTILITY lt lt Recall a Program gt gt 2 2 PROGRAM UTILITY lt lt Save a Program gt gt 2 3 PROGRAM UTILITY lt lt Delete a Program gt gt 3 UTILITY MENU lt lt Interface Utilities gt gt enter tesc 3 1 INTERFACE UTILITY Interface Setup lt lt Security Utilities gt gt enter f esc 4 1 SECURITY UTILITY Show Parameter 4 2 SECURITY UTILITY Lock Unit 4 3 SECURITY UTILITY User Password 4 4 SECURITY UTILITY Enable Password EE i Drehknopf PM2 oder PM3 zum Wahlen der Option dann ENTER betatigen zum Laden zeigt die gew hlte Option an Delay Units Unit Time ms Unit Distance m Ramps on changes Ramps Off Ramps On Software Version Version V1 01 Recall a Program 01 Default Flat 02 Default Classic 03 Default Disco 04 Default Jazz 05 Default Pop 06 Default RnB 07 Default Rock 08 Default Vocal 09 User Preset 01 32 User Preset 24 Save a Program 09 User Preset 01 32 User Preset 24 Delete a Program 09 User Preset 01 32 PUs
19. t das sobald das Ger t gesperrt wird besteht kein Zugriff auf die Einstellm glichkeiten der Parameter Sie werden jedoch auf dem LCD Bildschirm angezeigt 15 Wenn die Option not be shown ausgew hlt wurde hei t das sobald das Ger t gesperrt wird werden die Parameter gar nicht mehr angezeigt Bei dieser Option erscheint auf dem Bildschirm die folgende Meldung wenn man auf einen Parameter zugreifen m chte Lock Unit Dieses Untermen erm glicht dem Benutzer das Sperren des Ger tes Es lassen sich dann keine Parameter mehr einstellen oder ndern Wenn sich das Ger t im entsperrten Zustand befindet stehen s mtliche Parameter zum Einstellen zur Verf gung Wenn On ausgew hlt wird werden alle Parameter gesperrt und stehen nicht zum Einstellen zur Verf gung Wenn im Men Lock sperren gew hlt wird wird das Ger t gesperrt und das Sperrmen wird automatisch verlassen Die Bildschirmmaske kehrt zur ck zur Starteinstellung und zeigt die aktuell ausgew hlte Voreinstellung sowie ein Sperrsymbol neben dem Namen der Voreinstellung als Hinweis darauf dass der DEQ 230 gesperrt wurde 16 User Password aus dem Untermen User Password AL 4 Y Die Taste ENTER bet tigen um auf die Seite User Password zu gelangen Mit dem Drehknopf PM2 bzw PM3 ein Zeichen ausw hlen mit dem Drehknopf NAV PAR1 zwischen den verf gbaren Stellen wechseln und ein Passwort bestehend aus
20. the DEQ 230 will go ahead with the Set Program Name page and the subsequent overwrite on completion of the previously described storing process Note at any time it is possible to quit the storing action by pressing the ESC button 43 Delete a Program this page allows you to delete a preset already stored in the DEQ 230 memory By pressing the ENTER button and rotating the PM2 or PM3 encoder it is possible to scroll through the previously saved presets and the available empty locations identified by Empty Memory If no user presets are stored the Delete a Program screen will show empty memory locations for all 1 24 presets as shown in the example below for location 10 By using the PM2 or PM3 encoder it is possible to select a preset to be deleted Pressing the ENTER button on a selected preset will bring up the Enter to Delete page Showing the selected preset For example if we want to delete the preset 10 Velvet Club the screen will be the following tr f gt Delete 10 Velvet Club Confirming the deletion by pressing ENTER again will force the DEQ 230 to erase the selected preset and the following transitory screen will appear Delete a Program Note At any time it is possible to quit the deleting action by pressing the ESC button 44 Interface Utilities Sub menu this sub menu allows you to define the remote contro
21. 00KHz with the NAV PAR1 encoder The EQ sub menu screen will show the following 00kHz 6LoSh Note Once the desired Low Shelving filter is selected the PM3 can then be used to select the desired GAIN and when the GAIN is set at a value different from 0 0dB then the filter type cannot be changed until this GAIN is returned to 0 0dB Once in the Low Shelving Filter s edit screen all the filter s parameters can be modified using the NAV PAR1 PM2 and PM3 encoders for editing the Filter s High Cut Frequency Filter s Order and Gain The Hi Cut Frequency of the Low Shelving Filter can be edited using the NAV PAR1 encoder the Filter s Order can be adjusted by the PM2 encoder and the Gain the PM3 encoder Hi Cut Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1 24 of an Octave and can be adjusted by rotating the NAV PAR1 encoder Low Shelving Order the selectable Low Shelving Filter s range can be selected between the 1 Lo ist and the 2 Lo 2nd one Gain the selectable range of the Gain is from 15dB to 15dB in steps of 0 5 dB and can be adjusted by rotating the PM3 encoder 54 High Shelving Filter As an example if we want to set a high shelving filter within EQ 1 then the PM2 encoder has to be rotated counter clockwise until the desired High Shelving filter say 6HiSh appears on the screen the GAIN at say 3dB using the PM3 encoder a
22. 1 PM2 und PM3 alle Parameter des Filters zum Einstellen von Mittenfrequenz Bandbreite und Verst rkung modifizieren Die Mittenfrequenz des parametrischen Filters l sst sich mit dem Drehknopf NAV PAR1 einstellen die Bandbreite mit dem Drehknopf PM2 und die Verst rkung mit dem Drehknopf PM3 Center Frequency Der ausw hlbare Frequenzbereich betr gt 20 Hz bis 20 kHz in Schritten von einer 1 24 Oktave und l sst sich mit dem Drehknopf NAV PAR1 einstellen Bandwidth BW Die ausw hlbare Bandbreite betr gt 0 05 Oktave bis 3 Oktaven in Schritten von 0 05 Oktave und l sst sich mit dem Drehknopf PM2 einstellen Gain Die ausw hlbare Verst rkung betr gt 15 dB bis 15 dB in Schritten von 0 5 dB und l sst sich mit dem Drehknopf PM3 einstellen Low Shelving Filter Beispiel Wenn ein Tiefenfilter mit Kuhschwanzcharakteristik innerhalb des EQ 1 eingestellt werden soll den Drehknopf PM2 entgegen dem Uhrzeigersinn drehen bis das gew nschte Tiefenfilter mit Kuhschwanzcharakteristik z B 6LoSh auf dem Bildschirm erscheint die Verst rkung z B 3 0 dB mit dem Drehknopf PM3 einstellen und die obere Grenzfrequenz z B 1 00 kHz mit dem Drehknopf NAV PAR1 Die Untermen Bildschirmmaske des Equalizers zeigt Folgendes J Jt OU kHz 6LoSh 3 0dl gt J Anmerkung Sobald das gew nschte Tiefenfilter mit Kuhschwanzcharakteristik ausgew hlt wird l sst sich die gew nschte Verst rkung mit dem Drehknopf PM3 einstellen
23. 20 kHz in Schritten von einer 1 24 Oktave und l sst sich mit dem Drehknopf PM2 einstellen Low Pass Type and Order erm glicht die Auswahl von Typ und Ordnung des Tiefpassfilters des Equalizers Die unten aufgef hrten Filtertypen und Ordnungen des Tiefpassfilters werden mit dem Drehknopf PM3 ausgew hlt No Cut Off Butwrth 6dB Tiefpassfilter umgangen Butterworth Filter mit einer Flankensteilheit von 6 dB Oktave Butwrth 12dB Lnk Ril 12dB Bessel 12dB Butwrth 18dB Butwrth 24dB Lnk Ril 24dB Bessel 24dB Butterworth Filter mit einer Flankensteilheit von 12 dB Oktave Linkwitz Riley Filter mit einer Flankensteilheit von 12 dB Oktave Bessel Filter mit einer Flankensteilheit von 12 dB Oktave Butterworth Filter mit einer Flankensteilheit von 18 dB Oktave Butterworth Filter mit einer Flankensteilheit von 24 dB Oktave Linkwitz Riley Filter mit einer Flankensteilheit von 24 dB Oktave Bessel Filter mit einer Flankensteilheit von 24 dB Oktave Anmerkung 1 Sobald die gew nschten Optionen mit den beiden Drehkn pfen ausgew hlt werden werden sie nach Verlassen der Seite automatisch als aktuelle Werte im Systemstatus des DEQ 230 gespeichert Anmerkung 2 Zum Verlassen dieser Seite die Taste ESC bet tigen 22 Untermen EQ x Dieses Untermen erm glicht die Einstellung von 30 verf gbaren parametrischen Filtern oder Kuhschwanzfiltern f r die Equalizer Kan le Der DEQ 230 erm glicht dem Ben
24. 6 Zeichen eingeben Die aktuelle Position des Cursors f r die einzugebenden Zeichen wird durch einen blinkenden Unterstrich angezeigt W hrend dieser Einstellphase zeigt das Display DEQ230 als Passwort Der DEQ 230 verl sst das Untermen Unit Lock und springt auf die Seite des Untermen s User Password Insert Password Wenn das auf der Seite Confirm Password eingegebene Passwort mit dem auf der Seite Enter Password eingebenden Passwort bereinstimmt erscheint die folgende Bildschirm maske Das Passwort wird jetzt konfiguriert und im Ger t abgespeichert Der Benutzer kann jetzt den DEQ 230 mit dem Passwort sperren und je nach Einstellung des Parameters Password Enable Disable siehe folgenden Absatz damit den Zugriff auf ALLE Funktionen des Equalizers blockieren 17 Enable Password aus dem Untermen Enable Password 5 gt UR Yu i i User Password Die Taste ENTER bet tigen um zur Bildschirmmaske Enable Password zu gelangen Sobald ein Passwort durch die im vorhergehenden Absatz beschriebenen Schritte in den DEQ 230 eingegeben wird l sst sich die Passwort Funktion aktivieren Enable bzw deaktivieren Disable Damit wird der DEQ 230 gesperrt und der Zugriff auf s mtliche Funktionen eingeschr nkt Wenn ein Passwort eingegeben wurde l sst sich die Option Enable aktivieren aus dem Men ausw hlen Es besteht dann kein Zugriff a
25. 8 Default Vocal 09 User Preset 01 32 User Preset 24 Save a Program 09 User Preset 01 32 User Preset 24 Delete a Program 09 User Preset 01 32 PUser Preset 24 Interface Setup Source USB Source RS485 Parameter will be shown not be shown Lock Unit Lock Off Lock On User Password Enable Password Password Enable Password Disable For the details about the Password Setting Enable and Unit Lock refer to the Utility Menus Use section 35 MENU Channel A B Input Channels Editing Access by pushing the LIN RIN buttons NAV PAR1 Encoder NAV PAR1 Enc PM2 Enc PM3 Enc to navigate between menus to chose values for the parameters no need to confirm the chosen values which are automatically loaded during the encoders use 1 Output x Name Name Name Name enter tesc gt Name _ For Editing the Device s Name refer to the Details on the Utility Menus Use Section 2 Output x Name NGate Noise Gate Off a Noise Gate Off ENTER Noise Gate On 3 Output x Name Source Source Analog InA ENTER Tesc gt Source Analog InA PARI N A Analog InA Same as PAR2 en Analog InB Analog InA InB Digital Left Digital Right Digital L R 4 Output x Name Gain Gain 0 0 dB ENTER J t ESC gt Gain 0 0 dB PARI N A 15 dB Same as PAR2 15 dB 5 Output x Name Polarity Polarity Normal ESC ENTER gt Polarity Normal
26. III Stave Line DEQ 230 Digitaler Parametrischer Grafischer Equalizer Digital Parametric Graphic Equalizer Best Nr 25 4500 Bedienungsanleitung User Manual AF MONACOR MONACOR INTERNATIONAL GmbH amp Co KG Zum Falsch 36 28307 Bremen Germany INTERNATIONAL Copyright by MONACOR INTERNATIONAL All rights reserved DEUTSCH Bevor Sie einschalten Wir w nschen Ihnen viel Spa mit Ihrem neuen Ger t von img Stage Line Bitte lesen Sie diese Bedienungsanleitung vor dem Betrieb gr ndlich durch Nur so lernen Sie alle Funktionsm glich keiten kennen vermeiden Fehlbedienungen und sch tzen sich und Ihr Ger t vor eventuellen Sch den durch unsachgem en Gebrauch Heben Sie die Anleitung f r ein sp teres Nachlesen auf Der deutsche Text beginnt auf der Seite 3 ENGLISH Before switching on We wish you much pleasure with your new img Stage Line unit Please read these operating instructions carefully prior to operating the unit Thus you will get to know all functions of the unit operating errors will be prevented and yourself and the unit will be protected against any damage caused by improper use Please keep the operating instructions for later use The English text starts on page 33 DEUTSCH e Inbetriebnahme Sobald der DEQ 230 eingeschaltet wird erscheint der Name des Ger tes auf der LCD Anzeige JeEW 230 Equalizer 30 30 Eine Statusleiste zeigt den Fortschrit
27. ain GND and the USB RS485 connectors GND to the chassis MAIN LIFT GND Switch Actually can happen that sometime it is necessary to NOT connect the Main Ground to the Chassis in order to avoid GND loops This is possible using the MAIN GND LIFT switch When the switch is positioned on GND the Main Power Supply GND is connected to the Chassis USB RS485 LIFT GND Switch When using a USB or RS485 remote control connection can be that the GND of the USB or RS485 cable it is not connected to the remote controller GND In this case it is necessary to provide it from the processor s side and this can be done selecting the GND position with the USB RS485 switch On the other hand if the GND of the USB RS485 cable is already connected to the remote controller GND to connect the same ground also to the GND of the processor could create GND loops or generate GND noises In this case the switch on the position Lift will leave the cable GND not connected to the chassis of the DEQ 230 59 e USB RS485 Remote Control protocol for Preset Changing and Gain Volume controls The following is the HEX Code for controlling the DEQ 230 recall presets and master volume control Preset Changing CMD_RECALL_PRESET CMD 1BH A The User has to send the following Command including the number of the preset to load on the unit TX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 1BH NPreset 00H 00H 00H 00H 00H 00H 00H F7H
28. als aktuelle Werte im Systemstatus des DEQ 230 gespeichert Anmerkung 2 Zum Verlassen dieser Seite die Taste ESC bet tigen Volume page Diese Bildschirmmaske erm glicht die Einstellung des Ausgangspegels der Equalizer Kan le von 12 dB bis 6 dB Die Taste ENTER bet tigen Ein Pfeil gt erscheint links auf dem Bildschirm Dann die Tasten PM1 bzw PM2 bet tigen Der auf dem Bildschirm eingestellte Wert hat nur Einfluss auf den Ausgangspegel des ausgew hlten Equalizer Kanals Das folgende Beispiel zeigt eine Bildschirmmaske f r die Seite Volume in der die Verst rkung f r den Equalizer Kanal A mit der Bezeichnung Left auf 0 0dB eingestellt wurde 25 e MENU A B Output Channels Compressor Limiter Zugang ber die Tasten LCOMP RCOMP Vom Startbildschirm aus gelangt man durch Bet tigung der Taste LCOMP bzw RCOMP in das Men Equalizer s Compressor Sobald die Taste gedr ckt wird leuchtet die entsprechende blaue LED EDIT Die Untermen Seiten lassen sich durch Drehen des Drehknopfs NAV PAR1 im Uhrzeigersinn bzw entgegen dem Uhrzeigersinn durchlaufen Zum Einstellen der Parameter die Taste ENTER bet tigen Ein Pfeil gt erscheint links auf dem Bildschirm Dann die Parameterwerte mit den Drehkn pfen PM2 und PM3 ausw hlen und einstellen Bei einigen Parametern die aus drei unabh ngigen Werten bestehen muss man den Drehknopf PAR1 zur Hilfe nehmen z B f r Einstellungen der Filterparamet
29. an le einstellbereit wenn ihre blaue LED im Einstellmodus leuchtet Jetzt ndert der Slave Kanal seine Parameter entsprechend der Einstellung des Master Kanals Alle anderen Parameter bleiben beim Slave Kanal gleich wenn sie nicht ber die Verbindung zum Master Kanal eingestellt werden Anmerkung Die Verbindungsfunktion LINK ist KEINE Kopierfunktion Um den Limiter des Equalizer Kanals A mit der Bezeichnung Left einzustellen l sst sich durch Bet tigung der entsprechenden Taste LCOMP der Einstellmodus des Kompressor Kanals A aufrufen Die blaue LED unterhalb der LED Anzeigen LCOMP leuchtet Auf diese Weise wird die Master Funktion zugewiesen Die Parameter dieses Kanals erscheinen auf der LCD Anzeige Anschlie end die Taste EDIT des Kompressor Kanals B bet tigen Die entsprechende blaue LED leuchtet Jetzt gelten alle f r Kompressor Kanal A eingestellten Parameter auch f r Kanal B Um den Kanal von dieser Verbindung zu trennen die entsprechende Taste EDIT bet tigen Wenn die Einstellung des Master Kanals w hrend eines Verbindungsvorgangs verlassen wird wird dieser Vorgang automatisch beendet Der Verbindungsvorgang wird ebenfalls automatisch beendet wenn man beim Einstellen der Kompressor Kan le zur Einstellung eines Equalizer Kanal springt oder umgekehrt 28 e Zur cksetzen auf die Werkseinstellung Falls das Passwort verlorengeht oder der Benutzer das Ger t aus einem anderen Grund auf die Werkseinstellung zur ckse
30. bzw PM3 ausw hlen 20 Gain page Diese Bildschirmmaske erm glicht die Einstellung der Kanalpegel des Equalizers von 15dB bis 15dB Die Taste ENTER bet tigen Ein Pfeil gt erscheint links auf dem Bildschirm Dann die Tasten PM1 bzw PM2 bet tigen Der auf dem Bildschirm eingestellte Wert hat nur Einfluss auf den Eingangspegel des ausgew hlten Equalizer Kanals LIN RIN Das folgende Beispiel zeigt die Bildschirmmaske f r die Seite Gain in der die Verst rkung f r den Equalizer Kanal A mit der Bezeichnung Left auf 0 0dB eingestellt wurde Polarity page Diese Seite erm glicht die Einstellung der Polarit t des Equalizer Kanals mit dem Drehknopf PM1 bzw PM2 Die Polarit t ist entweder Normal oder Inverted d h um 180 Grad gedreht Das Beispiel unten zeigt die Bildschirmmaske Polarity in der die Polarit t f r den Equalizer Kanal A mit der Bezeichnung Left auf Normal eingestellt wurde Delay page Diese Seite erm glicht die Einstellung der Verz gerungszeit der Equalizer Kan le von 000 0000 ms bis 848 9984 ms in Schritten von 1 ms oder 20 8 us Zum Einstellen der Verz gerungszeit die Taste ENTER bet tigen Ein Pfeil gt erscheint links auf dem Bildschirm Dann mit dem Drehknopf PM2 die Verz gerungszeit in Schritten von 1 ms einstellen und mit dem Drehknopf PM3 die Feineinstellung der Verz gerungszeit in Schritten von 20 8 us vornehmen Das Beispiel unten zeigt eine Bilds
31. cherplatz 10 eingegeben wurde Die Taste ENTER erneut betatigen um den Namen der Voreinstellung zu speichern Der oben aufgef hrte Vorgang f hrt auf die Seite Enter to Save welche den ausgew hlten Speicherplatz der Voreinstellung und den endg ltig eingestellten Namen anzeigt Durch erneute Bet tigung de Taste ENTER wird die Voreinstellung unter dem ausgew hlten Namen am ausgew hlten Speicherplatz abgespeichert Die folgende Ubergangsmaske erscheint auf der LCD Anzeige Sobald die Voreinstellung gespeichert wird wird die oben aufgef hrte Bildschirmmaske ausgeblendet und die folgende Bildschirmmaske erscheint wieder Um w hrend des Speichervorgangs der Voreinstellung einen bestehenden Speicherplatz zu berschreiben diesen Speicherplatz auf der Seite Save a Program ausw hlen dann die Taste ENTER bet tigen Es erscheint die Frage ob diese Voreinstellung mit der nachfolgenden Bildschirmmaske ENTER to Overwrite berschrieben werden soll die die aktuell gespeicherte Voreinstellung sowie den Speicherplatz anzeigt En o Overwrite et Club 7 Velv Um fortzufahren die Taste ENTER erneut bet tigen Nach Beendigung des oben beschriebenen Speichervorgangs berschreibt der DEQ 230 den auf der Seite Set Program Name eingegebenen Namen Anmerkung Der Speichervorgang lasst sich jederzeit durch Betatigung der Taste ESC abbrechen 13 Delete a Program Diese Seite erm glicht das L sch
32. chirmmaske f r die Seite Delay in der die Verz gerungszeit f r den Equalizer Kanal A mit der Bezeichnung Left auf 160 1872 ms eingestellt wurde _ 460 1872mS 7 Untermen HPF Dieses Untermen erm glicht die Einstellung des Hochpassfilters HPF des Equalizers Das Beispiel unten zeigt eine Untermen Bildschirmmaske f r das Hochpassfilter in der das Filter f r den Equalizer Kanal A mit der Bezeichnung Left auf 24 dB Linkwitz Riley eingestellt wurde A DE gt 20 0Hz Lnk Ril 24dE Die Filterparameter lassen sich mit den Drehkn pfen PM2 und PM3 zum Einstellen der unteren Grenzfrequenz des Filters sowie des Filtertyps und der Filterordnung modifizieren Die untere Grenzfrequenz des Hochpassfilters lasst sich mit dem Drehknopf PM2 einstellen der Filtertyp und die Filterordnung mit dem Drehknopf PM3 A Low Cut Frequency der ausw hlbare Frequenzbereich betr gt 20 Hz bis 20 kHz in Schritten von einer 1 24 Oktave und l sst sich mit dem Drehknopfs PM2 einstellen High Pass Type and Order erm glicht die Auswahl von Typ und Ordnung des Hochpassfilters des Equalizers Die unten aufgef hrten Filtertypen und Ordnungen des Hochpassfilters werden mit dem Drehknopf PM3 ausgew hlt No Cut Off Butwrth 6dB Butwrth 12dB Lnk Ril 12dB Bessel 12dB Butwrth 18dB Butwrth 24dB Lnk Ril 24dB Bessel 24dB Anmerkung 1 Sobald die gew nschten Optionen mit den beiden Drehkn pfen
33. d Order this page allows you to select the Equalizer s Low Pass Filter Shape and Order The available shapes and orders for the Low Pass Filter that are accessible by rotating the PM3 encoder are listed below No Cut Off Low Pass Filter Bypassed Butwrth 6dB Butterworth Filter 6dB Oct Slope Butwrth 12dB Butterworth Filter 12dB Oct Slope Lnk Ril 12dB Linkwitz Riley Filter 12dB Oct Slope Bessel 12dB Bessel Filter 12dB Oct Slope Butwrth 18dB Butterworth Filter 18dB Oct Slope Butwrth 24dB Butterworth Filter 24dB Oct Slope Lnk Ril 24dB Linkwitz Riley Filter 24dB Oct Slope Bessel24dB Bessel Filter 24dB Oct Slope Notei1 once the desired options have been selected using the 2 encoders they are automatically saved as current and stored in the DEQ 230 system status once leaving the page Note2 to exit this page push the ESC button 32 EQ x sub menu from this sub menu it is possible to set the Equalizer s Channels 30 available Parametric or Shelving Filters The DEQ 230 allows the user to select either Bell or Shelving Parameters and assign them independently using the 30 available filters In order to select the filter s type it is necessary to have the filter s GAIN 0 0dB then using the PM2 encoder rotate it clockwise in order to decide the Bell filter s Bandwidth or counter clockwise to select the Shelving filter type Low or High and its order 1 or 2
34. der Seite vor Bet tigung der Taste ENTER zur ckzukehren Auf den Untermen Seiten die verschiedenen Optionen mit dem Drehknopf PM2 bzw PM3 durchbl ttern und anschlie end mit der Taste ENTER ausw hlen best tigen Anmerkung In jedem Untermen wird die aktuell ausgew hlte laufende Option mit einem Sternchen markiert das sich rechts neben der Bezeichnung auf der LCD Anzeige befindet Nicht ausgew hlte laufende Optionen werden OHNE Sternchen angezeigt Wird die Taste ENTER bei einer nicht ausgew hlten Option gedr ckt erscheint ein Sternchen Diese Option ist dann die aktuell ausgew hlte laufende Option Untermen System Utilities Dieses Untermen erm glicht verschiedenen Bedienschritte welche die Inbetriebnahme und die allgemeine Konfiguration des DEQ 230 betreffen Aus dem Untermen System Utilities die Taste ENTER bet tigen Dann mit dem Drehknopf NAV PAR1 auf die folgenden Seiten gehen Delay Time Distance Diese Seite erm glicht die Auswahl der Ma einheit f r die Verz gerung Time in Millisekunden ms or Distance in Metern m Delay Units Durch Bet tigung der Taste ENTER und des Drehknopfs PM2 bzw PM3 l sst sich die f r die Verz gerung verwendete Ma einheit ausw hlen Diese wird mit der Taste ENTER best tigt Die folgende Abbildung zeigt Time in Millisekunden als gew hlte Verz gerungseinheit Ramps on changes Diese Seite erm glicht die Aktivierung Deaktivierung ei
35. die untere Grenzfrequenz z B 1 00 kHz mit dem Drehknopf NAV PAR1 Anmerkung Sobald das gew nschte H henfilter mit Kuhschwanzcharakteristik ausgew hlt wird l sst sich die gew nschte Verst rkung mit dem Drehknopf PM3 einstellen Wenn die Verst rkung auf einen anderen Wert als 0 0 dB eingestellt wird l sst sich der Filtertyp solange nicht ndern bis die Verst rkung wieder auf 0 0 dB zur ckgestellt wird In der Bearbeitungsmaske f r das H henfilter mit Kuhschwanzcharakteristik lassen sich mit den Drehkn pfen NAV PAR1 PM2 und PM3 alle Parameter des Filters zum Einstellen der unteren Grenzfrequenz Ordnung und Verst rkung modifizieren Die untere Grenzfrequenz des H henfilters mit Kuhschwanzcharakteristik l sst sich mit dem Drehknopf NAV PAR1 einstellen die Ordnung mit dem Drehknopf PM2 und die Verst rkung mit dem Drehknopf PM3 Lo Cut Frequency Der ausw hlbare Frequenzbereich betr gt 20 Hz bis 20 kHz in Schritten von einer 1 24 Oktave und l sst sich mit dem Drehknopf NAV PAR1 einstellen High Shelving Order Der ausw hlbare Bereich des H henfilters mit Kuhschwanzcharakteristik umfasst 1 Ordnung Lo 1st und 2 Ordnung Lo 2nd Gain Die ausw hlbare Verst rkung betr gt 15 dB bis 15 dB in Schritten von 0 5 dB und l sst sich mit dem Drehknopf PM3 einstellen Anmerkung 1 Sobald die gew nschten Optionen mit den 3 Drehkn pfen ausgew hlt werden werden sie nach Verlassen der Seite automatisch
36. die Position GND gestellt wird erfolgt eine Masseverbindung zwischen dem Schutzleiter der Stromversorgung und der Geh usemasse Schalter USB RS485 LIFT GND Bei der Fernsteuerung ber USB oder RS485 kann es vorkommen dass die Masse des USB oder RS485 Kabels keine Verbindung zur Masse der Fernbedienung hat In diesem Fall ist es erforderlich diese Verbindung vom Prozessor aus herzustellen Dazu den Schalter USB RS485 in die Position GND stellen Wenn jedoch die Masse des USB RS485 Kabels bereits mit der Masse der Fernbedienung verbunden ist k nnte der Anschluss derselben Masse an die Masse des Prozessors zu Masseschleifen oder Eigenrauschen f hren In diesem Fall f hrt die Position Lift des Schalters dazu dass die Kabelmasse von der Geh usemasse des DEQ 230 getrennt wird 29 e USB RS485 Fernsteuerprotokoll zum Andern von Voreinstellungen und Reglern fur Verstarkung Lautstarke Nachfolgend der Hexadezimalcode zum Steuern der abrufbaren Voreinstellungen und des Gesamtlautstarkereglers Andern von Voreinstellungen CMD_RECALL_PRESET CMD 1BH A Der Benutzer muss den folgenden Befehl zusammen mit der Nummer der Voreinstellung die geladen werden soll senden TX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 1BH NPreset 00H 00H 00H 00H 00H 00H 00H F7H XX 0 31 ID device Npreset 0 31 Presetnumber Der Mikrocontroller des DEQ 230 pr ft
37. e USB oder RS485 f r die Fernsteuerung des DEQ 230 Aus dem Men Interface Utilities die Taste ENTER bet tigen um zur Einstellung der Schnittstelle Interface Setup zu gelangen Interface Setup Diese Bildschirmmaske erm glicht die Auswahl des Fernsteuerprotokolls f r den DEQ 230 Durch Bet tigung der Taste ENTER und des Drehknopfs PM2 bzw PM3 kann zwischen den beiden m glichen Schnittstellen USB oder RS485 des DEQ 230 gew hlt werden Nach Bet tigung der Taste ENTER bei der gew hlten Schnittstelle erscheint ein Sternchen rechts neben der Bezeichnung auf der LCD Anzeige siehe Beispiel unten bei dem die gew hlte Schnittstelle USB lautet 7 nterface Se Source USB Untermen Security Dieses Untermen erm glicht dem Benutzer das Einstellen der angezeigten Parameter das Sperren des DEQ 230 und das Einstellen eines Passwort mit dem die Funktionen und Kontrollen des Ger tes lediglich auf Personen beschr nkt werden die Zugang zum entsprechenden Passwort haben Die Taste ENTER bet tigen und die Optionen mit dem Drehknopf NAV PAR1 durchlaufen Show Parameter Durch Bet tigung der Taste ENTER aus dem o a Men gelangt man in das Untermen Show Parameter Die Taste ENTER erneut bet tigen und mit dem Drehknopf PM2 bzw PM3 die Optionen be shown und not be shown w hlen Ein Sternchen markiert die ausgew hlte Option Wenn die Option be shown ausgew hlt wird hei
38. e Gate On PAR1 N A Analog InA Analog InB Analog InA InB Digital Left Digital Right Digital L R PAR1 N A 15 dB 15 dB PAR1 N A Normal Invert PAR1 N A 000 0000mS 1 ms steps 848 0000mS PAR1 N A Freq 20Hz 20kHz PAR1 N A Freq 20Hz 20kHz Same as PAR2 Same as PAR2 Same as PAR2 000 0000mS 20 8 us steps 000 9984mS Type Slope No Cut Off Bessel 24dB Oct Type Slope No Cut Off Bessel 24dB Oct 9 1 9 2 9 3 10 Output x Name PEQ SHV 1 30 1 00kHz BW SHV_Slope 1 00 up to 12dB 0 0dB Nur wenn die Filterverstarkung 0 0dB betr gt ist mit dem Drehknopf PM2 eine Auswahl zwischen einem Bell Filter und einen Kuhschwanzfilter m glich ENTER J t ESC Wenn bei einer Filterverst rkung 0 0 dB ber den Drehknopf PM2 ein Bell Filter ausgew hlt wurde und die Bandbreite BW gr er als O ist lassen sich die Bell Filter mit den folgenden Parametern einstellen Output x Name EQ X bis zu 30 Filter verf gbar gt 1 00kHz BW 1 00 0 0dB Freq 20Hz 20kHz Wenn bei einer Filterverst rkung 0 0 dB ber den Drehknopf PM2 ein Tiefenfilter mit Kuhschwanzcharakteristik ausgew hlt wurde und die Flankensteilheit festgelegt wurde 1 Ordnung oder 2 Ordnung 6 dB oder 12 dB l sst sich das Tiefenfilter mit Kuhschwanzcharakteristik mit den folgenden Parametern einstellen Output x Name EQ X bis zu 30 Filter verf gbar gt 1 00kHz 6 12 LoSh 0 0dB Fre
39. e screen will be the following Once pushing ENTER the DEQ 230 will ask the confirmation before to copy on the ChA the complete ChB setting Set Eq as graphic mode this utility is allowing to set the center frequencies of the all filters of the related Equalizer s Channel spaced by 1 3 of octave as 30bands Graphic Equalizers If selected the Equalizer s Channel A named Left the screen will be the following Once pushing ENTER the DEQ 230 will ask the confirmation before to set the center frequencies of the all filters of the related Equalizer s Channel spaced by 1 3 of octave 57 e Equalizer s Channels LIN RIN and Compressor Limiter s Channels LCOMP RCOMP Last Edited Parameter Return Function Once you have escaped out of parameter editing within the individual Equalizer s Channel or Compressor s Channel the DEQ 230 will remember this last editing action on that Channel When you return for your next editing action pressing the EDIT button on that channel will immediately return you to the screen related to this last editing action This function makes fine tuning or modifying easier when it is necessary to make a number of adjustments to the same parameter in a short time sequence e Equalizer s Channels and Compressor Limiter s Channels LINK Function The DEQ 230 is able to perform a unique LINK MODE between Equalizer s Channels as well as a link between Compressor s Channels to enable quick and immediate editing you cannot li
40. e user can now decide to lock the DEQ 230 by Password inhibiting the access to ALL Equalizer s functions depending on the setting of the parameter Password Enable Disable explained in the following paragraph 47 Enable Password from the Enable Password sub menu SECURITY L eo User Password Press ENTER to gain access to the Enable Password screen Once a Password has been entered into the DEQ 230 through the steps described in the previous paragraph it is possible to Enable or Disable the password function and therefore lock the DEQ 230 restricting access to all functions When a password has been entered you will be able to select the Enable option from the menu and the unit will not be accessible for editing In Locked by Password Status all DEQ 230 functions are inhibited to the User including the use of the Mute LIN RIN and Bypass LOUT ROUT LCOMP RCOMP buttons The only access available is to the parameters of the input output channels accessible by pressing the edit button ONLY to READ the values no editing possible if the be shown flag in the Show Parameter Sub Menu has been selected Once Locked by Password the keylock icon will appear on the default LCD screen and no menu pages will be accessible with the exception of the User Password option To regain access to the full operation of the DEQ 230 ENTER to the User Password
41. en einer bereits im DEQ 230 gespeicherten Voreinstellung Durch Bet tigung der Taste ENTER und des Drehknopfs PM2 bzw PM3 lassen sich die zuvor gespeicherten Voreinstellungen und die verf gbaren leeren Speicherpl tze gekennzeichnet mit Empty Memory durchlaufen Wenn keine Benutzervoreinstellungen gespeichert wurden zeigt die Bildschirmmaske Delete a Program verf gbare Speicherpl tze f r alle Voreinstellungen 1 24 siehe Beispiel unten f r Speicherplatz 10 7 Wenn Voreinstellungen vorhanden sind werden diese auf der Seite Delete a Program angezeigt wie folgt Durch Bet tigung des Drehknopfs PM2 bzw PM3 l sst sich eine zu l schende Voreinstellung ausw hlen Nach Bet tigung der Taste ENTER bei einer ausgew hlten Voreinstellung erscheint die Seite LEnter to Delete mit der ausgew hlten Voreinstellung Wenn z B die Voreinstellung 10 gel scht werden soll zeigt die Bildschirmmaske Nach Best tigung des L schvorgangs durch erneute Bet tigung der Taste ENTER l scht der DEQ 230 die ausgew hlte Voreinstellung Die folgende Ubergangsmaske erscheint Sobald die Voreinstellung gel scht wird wird die o a Bildschirmmaske ausgeblendet und die folgende Bildschirmmaske erscheint wieder Anmerkung Der Speichervorgang l sst sich jederzeit durch Bet tigung der Taste ESC abbrechen 14 Untermen Interface Utilities Dieses Untermen erm glicht die Definition der Schnittstell
42. er Anmerkung Alle Parameter lassen sich mit Hilfe der Drehkn pfe NAV PAR1 PM2 und PM3 einstellen Der aktuell angezeigte Wert der ausgew hlten Option wird bei Bet tigung der Drehkn pfe AUTOMATISCH geladen und beim Verlassen der Seite als aktueller Wert abgespeichert Untermen Limiter Diese Seite erm glicht die Einstellung der Limiter f r die Equalizer Kan le Das folgende Beispiel zeigt eine Bildschirmmaske f r die Seite Limiter in der die Ansprechzeit f r den Limiter auf 5 ms die R ckstellzeit auf 0 2 s und der aktive Schwellwert auf 5 dB eingestellt wurde Nach der Bet tigung der Taste ENTER lassen sich die Limiter Parameter mit den Drehkn pfen NAV PAR1 PM2 und PM3 zum Bearbeiten der Ansprechzeit Attack Time des Limiters A der R ckstellzeit Release Time R und des Schwellwertes Threshold modifizieren Nach der Bet tigung der Taste ENTER ndert sich die o a Bildschirmmaske wie folgt imite R 0 28 5 0dE Die Ansprechzeit A l sst sich mit dem Drehknopf NAV PAR1 einstellen die R ckstellzeit R mit dem Drehknopf PM2 und der Schwellwert des Limiters mit dem Drehknopf PM3 Attack Time A Der ausw hlbare Bereich der Ansprechzeit des Limiters betr gt 5 ms bis 200 ms in Schritten von 1 ms von 5 ms bis 20 ms dann 5 ms von 20 ms bis 30 ms dann 10 ms von 30 ms bis 100 ms und 20 ms von 100 ms bis 200 ms Die Ansprechzeit des Limiters l sst sich mit dem Drehknopf NAV PAR1 einstellen
43. er are listed below No Cut Off High Pass Filter Bypassed Butwrth 6dB Butterworth Filter 6dB Oct Slope Butwrth 12dB Butterworth Filter 12dB Oct Slope Lnk Ril 12dB Linkwitz Riley Filter 12dB Oct Slope Bessel 12dB Bessel Filter 12dB Oct Slope Butwrth 18dB Butterworth Filter 18dB Oct Slope Butwrth 24dB Butterworth Filter 24dB Oct Slope Lnk Ril 24dB Linkwitz Riley Filter 24dB Oct Slope Bessel 24dB Bessel Filter 24dB Oct Slope Notel once the desired options have been selected using the 2 encoders they are automatically saved as current and stored in the DEQ 230 system status once leaving the page Note2 to exit this page push the ESC button sl LPF sub menu from this sub menu it is possible to set the Equalizer s Channels Low Pass Filter LPF The following is an example of a LPF sub menu screen with the filter set at 24dB Linkwitz Riley on Equalizer s Channel A named Left The filter s parameters can be modified by use the PM2 and PM3 encoders for editing the Filter s High Cut Frequency and the Filter s Type and Order The High Cut Frequency of the Low Pass Filter can be edited using the PM2 encoder and the Filter s Type and Order can be edited by using the PM3 encoder High Cut Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1 24 of an Octave and can be adjusted by rotating the PM2 encoder Low Pass Type an
44. er Preset 24 Interface Setup Source USB Source RS485 Parameter will be shown not be shown Lock Unit Lock Off Lock On User Password Enable Password Password Enable Password Disable Details zu den Funktionen Password Setting Enable und Unit Lock siehe Abschnitt Mend Utillity MENU Channel A B Input Channels Editing Zugang ber die Tasten LIN RIN Drehknopf NAV PAR1 zum Navigieren durch die Men s 1 Output x Name Name Name Name enter tesc gt Name _ 2 Output x Name NGate Noise Gate Off ENTER 3 Output x Name Source Source Analog InA enter f esc gt Source Analog InA lt a ENTER 4 Output x Name Gain Gain 0 0 dB enter tesc gt Gain 0 0 dB 5 Output x Name Polarity Polarity Normal enter f ESC gt Polarity Normal 6 Output x Name Delay Delay 0 000 ms ENTERS Tesc gt Delay 0 000 ms 7 Output x Name HPF 20 0 Hz No Cut Off enter f esc gt 20 0 Hz No Cut Off 8 Output x Name LPF 20 0 Hz No Cut Off ENTER f Esc gt 20 0 Hz No Cut Off Drehknopf NAV PAR Drehknopf PM2 Drehknopf PM3 zum Ausw hlen von Werten f r die Parameter die Werte brauchen nicht best tigt zu werden sie werden w hrend der Bet tigung der Drehkn pfe automatisch geladen Zum Einstellen des Ger tenamens siehe Abschnitt Men Utility Noise Gate Off Nois
45. es 0 005 Frequenzgang Bypass 665 20 Hz 20 kHz 1 dB Stromversorgung unzuuanseunnnennnee Schaltnetzger t Fernsteuerung nenn USB RS485 nderungen vorbehalten Soll das Ger t endg ltig aus dem Betrieb genommen werden bergeben Sie es um Zur umweltgerechten Entsorgung einem rtlichen Recyclingbetrieb 32 ENGLISH e Getting Started As soon as the DEQ 230 is turned ON the device model name will appear in the LCD screen JEL J Equalizer 30 30 and a status bar will show the progress of the DEQ 230 initialization process The DEQ 230 has eight factory pre set Default Flat Default Classic Default Disco Default Jazz Default Pop Default RnB Default Rock and Default Vocal After the initialization the DEQ 230 will show on the LCD the first of the embedded preset or the last one selected prior to the unit being turned off First time activation will default to the first of the preset 7 r JEL i Default Flat i Described below are the functions of the front panel control buttons and encoders for the DEQ 230 Encoders and ENTER ESC buttons The DEQ 230 is equipped with 3 Relative Encoders NAV PAR1 PM2 and PM3 These encoders allow you to navigate the user interface and edit sections of the processor They allow the user to navigate within the screen for the selection of sub menus pages and parameters and to se
46. est tigung l uft der entsprechende Prozess l uft ab Flat Equalizer Dieses Programm erm glicht das Zur cksetzen aller Filter des entsprechenden Equalizer Kanals Wenn der Equalizer Kanal A mit der Bezeichnung Left gew hlt wurde sieht die Bildschirmmaske aus wie folgt Nach Bet tigung der Taste ENTER verlangt der DEQ 230 eine Best tigung bevor alle Filter zur ckgesetzt werden Nach erneuter Bet tigung der Taste ENTER setzt der DEQ 230 s mtliche Filter zur ck Copy Equalizer from ChX Dieses Programm erm glicht das Kopieren der kompletten Einstellungen eines Kanals auf den aktuell gew hlten Equalizer Kanal Wenn der Equalizer Kanal A mit der Bezeichnung Left gew hlt wurde sieht die Bildschirmmaske aus wie folgt Nach Bet tigung der Taste ENTER verlangt der DEQ 230 eine Best tigung bevor die Einstellungen von Kanal B auf Kanal A kopiert werden Set Eq as graphic mode Dieses Programm erm glicht die Einstellung der Mittenfrequenzen aller Filter des entsprechenden Equalizer Kanals im Abstand von 1 3 Oktave als 30 Band Graphic Equalizer Wenn der Equalizer Kanal A mit der Bezeichnung Left gew hlt wurde sieht die Bild schirmmaske aus wie folgt Nach Bet tigung der Taste ENTER verlangt der DEQ 230 eine Best tigung bevor die Mittenfrequenzen aller Filter des entsprechenden Equalizer Kanals im Abstand von 1 3 Oktave eingestellt werden 21 e Ruckkehrfunktion zur letzten Parametereinstellung f r die
47. g of the Master channel during a Link session will automatically terminate that session The Link will also be automatically terminated if during the editing of Compressor s Channels you jump across to begin editing an Equalizer s Channel or vice versa 58 e Factory Reset In the event of the password being lost or any other reason the user may require the unit to be reset to the original factory settings a Factory Reset that will clear all settings of the DEQ 230 and return the device to the original factory setting is available to the user Note Continuing with this process will mean the DEQ 230 will re initialize to the original factory settings and any previously stored information and changed parameters will be permanently lost Use the following procedure to perform the factory reset 1 While the DEQ 230 is switched OFF simultaneously press the ENTER ESC UTILITY buttons on the front panel 2 Maintain pressure on all three buttons as you turn the power switch to On and the following LCD screen appears on the DEQ 230 Memory Reset 3 Release the buttons and wait for the DEQ 230 to re initialize Once completed the DEQ 230 will resume regular operation as though it was a new unit from the factory and no previously programmed parameters will be available for use e GND and USB RS485 LIFT switches The DEQ 230 on its back panel is providing a couple of switches allowing to connect or left unconnected the power Supply M
48. have an asterisk showing to the right of the description on the LCD screen Options that are not selected running will be displayed with NO Asterisk Pushing the ENTER button on an unselected option will mean an asterisk will then appear and this option will now take over as the currently selected running option System Utilities Sub menu this sub menu allows to access several operations related to the DEQ 230 Start Up and General Configuration From the System Utilities Sub menu pushing ENTER and then using the NAV PAR1 encoder for scrolling will give access to the following pages Delay Time Distance this page allows you to select the measurement unit to be used for the Delays Time in milliseconds ms or Distance in meters m Delay Units By pressing ENTER and rotating the PM2 or PM3 encoder it is possible to select the measurement unit to be used for the delay which will be confirmed by pushing the ENTER button The following screen shows the selected delay measurement is Time milliseconds 39 Ramps on changes this page allows you to activate or de activate Fading in and Fading out ramps on the input output volumes when any parameter changes When connected to the DEQ 230 by the PC remote control software it is possible to request Sudden parameter changes where the difference between the old parameter and the new one can cause unwanted click noises big d
49. he location 32 Through the Recall a Program page the Factory and the available user s preset can be recalled for the DEQ 230 filters setting By pressing ENTER and rotating the PM2 or PM3 encoders it is possible to scroll through all current available factory and user presets If NO USER PRESETS are stored yet the screen will show Only the factory presets If presets have previously been stored by the user anyone of them can be recalled starting from the location 09 41 By using the PM2 or PM3 encoder it is possible to scroll through the stored presets Once the desired preset appears on the screen select it by pressing the ENTER button and this will force the DEQ 230 to begin to load this selected preset and the following transitory screen will appear Once loaded the DEQ 230 will exit to the Recall a Program screen automatically and the above screen will disappear Note at any time it is possible to quit the recalling action by pressing the ESC button Save a Program this page allows you to store a new preset in the DEQ 230 s memory By pressing the ENTER button and rotating the PM2 or PM3 encoder it is possible to scroll through the previously saved presets and the available empty locations identified by Empty Memory If no user presets are stored the Save a Program screen will show empty memory locations for all 09 32 presets as s
50. his page it is possible to set the Equalizer s Channels Delay Time from 000 0000mS up to 848 9984mS by steps of 1mS or 20 8uS To set the Delay time press ENTER an arrow will appear on the left of the screen gt then use the PM2 encoder to set the Delay Time in steps of 1mS and the PM3 for setting the fine Delay Time in steps of 20 8 microseconds The following is an example screen for the Delay page where the Delay Time of Equalizer s Channel A named Left is set to 160 1872mS HPF sub menu from this sub menu it is possible to set the Equalizer s Channels High Pass Filter HPF The following is an example of a HPF sub menu screen with the filter set at 24dB Linkwitz Riley on Equalizer s Channel A named Left The filter s parameters can be modified by use the PM2 and PM3 encoders for editing the Filter s Low Cut Frequency and the Filter s Type and Order The Low Cut Frequency of the High Pass Filter can be edited using the PM2 encoder and the Filter s Type and Order can be edited by using the PM3 encoder Low Cut Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1 24 of an Octave and can be adjusted by rotating the PM2 encoder High Pass Type and Order allows you to select the Equalizer s High Pass Filter Shape and Order The available shapes and orders for the High Pass Filter that are accessible by rotating the PM3 encod
51. hown in the example below for location 10 When storing an edited configuration for the DEQ 230 select the location for a preset from the 24 available by using the PM2 or PM3 encoders Once the desired location appears on the screen press ENTER again to reach the Set Program Name page In this page the User can enter a Preset Name up to 16 Characters by using the PM2 or PM3 encoder to choose a character and the NAV PAR1 encoder to move between the 16 available locations for the character s positioning The current position of the cursor is shown by a blinking underscore 42 The following is an example of a screen while entering the preset name Velvet Club in location 10 To store the Preset Name press the ENTER button again The above action will take you to the Enter to Save page showing the selected location for the preset and the final edited name Pressing ENTER again will store the preset in the selected location with the chosen name and the following transitory screen will appear on the LCD If during the Preset Storing process you want to overwrite an existing memory location select this location in the Save a Program page then ENTER and you will be asked if you want to overwrite this preset with the following ENTER to Overwrite screen displaying the currently stored preset and location If you wish to proceed press ENTER again and
52. ie LED BYPASS nicht leuchtet dann f hrt der entsprechende Ausgangskanal des Equalizers die aktuelle Einstellung aus Wenn die Tasten LCOMP RCOMP gedr ckt und l nger als eine Sekunde gedr ckt gehalten werden wird die Kompressor Einstellung entweder umgangen bypassed und die Einstellungen des Kompressors werden zur ckgesetzt oder der Kompressor f hrt die aktuelle Einstellung aus Die rote LED leuchtet wenn der Kompressor umgangen wird Wenn die LED BYPASS nicht leuchtet dann f hrt der entsprechende Ausgangskanalkompressor des Equalizers die aktuelle Einstellung aus Durch eine kurze Bet tigung der Tasten LOUT ROUT gelangt man zu den Programm Funktionen f r die Kan le des Equalizers weitere Einzelheiten zu den Programm Funktionen des Equalizers folgen Die blaue LED UTIL leuchtet Durch eine kurze Bet tigung der Tasten LCOMP RCOMP gelangt man in das Einstellmen f r den Kompressorbereich des Equalizers weitere Einzelheiten zum Einstellen des Kompressors folgen Die blaue LED EDIT leuchtet e Men und Men strukturen des DEQ 230 Wie bereits oben erw hnt zeigt der Startbildschirm die folgende Werkseinstellung Default Flat Von hier gelangt man mit den Tasten UTILITY LOUT ROUT LCOMP RCOMP ENTER und ESC in die Untermen s S mtliche Parameter und Werte werden ber die Drehkn pfe NAV PAR1 PM2 und PM3 eingestellt siehe nachfolgende Men strukturen MENU UTILITY MENU Zugang iiber
53. ifferences in volume changes or bumps big differences in Hp Lp filters cutting frequency values as the DSP reconfigures The Fading In and Fading Out ramps eliminate any potential clicks and bumps This function can be de activated when the unit needs to be used in live conditions and small parameter adjustments are requested on the fly during live performance The following screen shows the Fading ramps function is Off and therefore de activated Software Version this page allows you to confirm the Software Version running on the DEQ 230 Software Version The correct Software Version is V1 01 40 Program Utilities Sub menu this sub menu allows you to access several options related to the DEQ 230 operating mode and to manage the presets stored and recallable within the Unit Program Utilities By pressing the ENTER button and then using the NAV PAR1 encoder the following pages can be accessed Recall a Program this page allows the Loading of a preset program The DEQ 230 already is containing 8 Factory presets occupying the first 8 positions of the Preset list which setting is shown in the A Appendix The 8 Factory presets are the following 1 Default Flat 2 Default Classic Default Disco Default Jazz Default pop Default RnB Default Rock Default Vocal CON OV U1 BR W You can store up to 24 presets in the DEQ 230 memory starting from the location 09 up to t
54. l interface USB or RS485 to be used for controlling the DEQ 230 From Interface Utilities press ENTER to access the Interface Setup Interface Setup this screen allows you to choose the remote control protocol for the DEQ 230 By pressing ENTER and then using the PM2 or PM3 encoders you can choose between the two possible interfaces USB or RS485 for the DEQ 230 Pressing ENTER on a selected source will make an asterisk appear to the right of the description on the LCD as in the following example which shows the selected interface as USB 45 Security Sub menu this sub menu allows the User to set the parameters shown lock the DEQ 230 and set a Password therefore limiting the unit s functions and controls to those who have only access to the appropriate Password Press ENTER and then use the NAV PAR1 to scroll between options Show Parameter Pressing ENTER from the above menu will access the Show Parameter De yy Y Y Show Parameter Sub Menu Press ENTER again and use the PM2 or PM3 encoders to scroll between the be shown and not be shown options An asterisk will highlight which option is selected Choosing the be shown option means that once the unit is locked you cannot access parameter editing features but they will be displayed on the LCD screen Choosing the not be shown option means that once the unit is locked the parameters will not be shown a
55. lect the values to be assigned during the editing operations The ENTER and ESC buttons allow the user to confirm or NOT confirm the operations performed by the encoders e UTILITY LIN RIN and LOUT ROUT LCOMP RCOMP buttons The UTILITY button allows the User to enter the Sub menus and set the general characteristics of the Equalizer The LIN and RIN buttons allow the User to enter the Editing Menus of the Equalizer s Input Channels or to MUTE the Equalizer s Outputs LOUT ROUT and LCOMP RCOMP buttons allow the User to access UTILITY functions related to the 33 Equalizer LOUT ROUT or to enter the Editing Menus of the Equalizer s Compressors Section LCOMP RCOMP The BYPASS function allows to bypass the Equalizer setting LOUT ROUT or the Compressor setting LCOMP RCOMP As understood the LIN RIN as well as the LOUT ROUT and LCOMP RCOMP buttons have double functions dependent on the push and hold time When the LIN RIN buttons are pushed and held for more than one second Input Channels LIN or RIN are either muted or unmuted The red LED will illuminate when the Channel is muted When the MUTE LED is OFF then the related Input Channel is UN MUTED A momentary push of the LIN RIN buttons enters the Editing Mode for the Equalizer s Channels see later for the Equalizer s Channel Editing details The blue EDIT LED will now be ON When the LOUT ROUT buttons are pushed and held for more than one second the Equalize
56. lizer s Channels Output Level from 12dB to 6dB press ENTER an arrow will appear on the left of the screen gt then use the PM1 or PM2 buttons The value set on this screen will only affect the output level of the selected Equalizer s Channel The following is an example screen for the Volume page where the Gain of the Equalizer s Channel A named Left is set to 0 0dB toutA olume 0 0dB 55 e MENU A B Output Channels Compressor Limiter Access by pushing the LCOMP RCOMP buttons From the Default Screen it is possible to access the Equalizer s Compressor menu by pressing the LCOMP or RCOMP button Once pressed the related blue EDIT LED will turn ON The Sub Menus pages can now be scrolled through by rotating clockwise and counter clockwise the NAV PAR1 encoder For parameter editing it is necessary to press ENTER and an arrow will appear on the left of the screen gt Then use the PM2 and PM3 encoders for selecting and setting the parameter values On some parameters that have three independent values you will also need to use the PAR1 encoder for example for the filter s parameter setting Note All parameter editing can be done using the NAV PAR1 PM2 and PM3 encoders and the current shown value of the selected option is AUTOMATICALLY loaded during the encoders use and stored as the current value once leaving the
57. n dem Uhrzeigersinn die Auswahl der Kuhschwanzfilter eingegeben Wenn der Drehknopf PM2 immer noch weiter gegen den Uhrzeigersinn gedreht wird sind die Kuhschwanzfilter und deren Ordnung in der folgenden Reihenfolge verf gbar 1 Tiefenfilter erster Ordnung mit Kuhschwanzcharakteristik Low Shelving 6LoSh auf dem Bildschirm 2 Tiefenfilter zweiter Ordnung mit Kuhschwanzcharakteristik Low Shelving 12LoSh auf dem Bildschirm 3 H henfilter erster Ordnung mit Kuhschwanzcharakteristik High Shelving 6HiSh auf dem Bildschirm 4 H henfilter zweiter Ordnung mit Kuhschwanzcharakteristik High Shelving 12HiSh auf dem Bildschirm Sobald das gew nschte Kuhschwanzfilter ausgew hlt wird l sst sich die gew nschte Verst rkung mit dem Drehknopf PM3 einstellen Wenn die Verst rkung auf einen anderen Wert als 0 0 dB eingestellt wird l sst sich der Filtertyp solange nicht ndern bis die Verst rkung wieder auf 0 0 dB zur ckgestellt wird 23 BELL Filter Beispiel Wenn ein Bell Filter innerhalb des EQ 1 eingestellt werden soll muss die Bandbreite mit dem Drehknopf PM2 auf einen gew nschten Wert z B 1 00 eingestellt werden die Verst rkung z B 3 dB mit dem Drehknopf PM3 und die Mittenfrequenz z B 1 00 kHz mit dem Drehknopf NAV PAR1 Die Untermen Bildschirmmaske des Equalizers zeigt Folgendes 1 00kHz BW 1 00 3 0dE In der Bearbeitungsmaske f r das Bell Filter lassen sich mit den Drehkn pfen NAV PAR
58. nd the Low Cut Frequency at say 1 00KHz with the NAV PAR1 encoder Note Once the desired High Shelving filter is selected the PM3 can then be used to select the desired GAIN and when the GAIN is set at a value different from 0 0dB then the filter type cannot be changed until this GAIN is returned to 0 0dB Once in the High Shelving Filter s edit screen all the filter s parameters can be modified using the NAV PAR1 PM2 and PM3 encoders for editing the Filter s Low Cut Frequency Filter s Order and Gain The Lo Cut Frequency of the High Shelving Filter can be edited using the NAV PAR1 encoder the Filter s Order can be adjusted by the PM2 encoder and the Gain the PM3 encoder Lo Cut Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1 24 of an Octave and can be adjusted by rotating the NAV PAR1 encoder High Shelving Order the selectable High Shelving Filter s range can be selected between the 1 Lo ist and the 2 Lo 2nd one Gain the selectable range of the Gain is from 15dB to 15dB in steps of 0 5 dB and can be adjusted by rotating the PM3 encoder Note once the desired options have been selected using the 3 encoders they are automatically Saved as current and stored in the DEQ 230 system status once leaving the page Note2 to exit this page push the ESC button Volume page from this screen it is possible to set the Equa
59. ner Uberblendfunktion f r die Eingangs Ausgangslautst rken wenn sich Parameter ndern Bei Anschluss des DEQ 230 ber die Fernsteuersoftware des PC lassen sich pl tzliche Parameter nderungen vornehmen wobei der Unterschied zwischen altem und neuem Parameter Zu unerw nschten Klickger uschen gro e Unterschiede bei der Lautst rkeeinstellung oder Schlagger uschen gro e Unterschiede in den Grenzfrequenzwerten der Hochpass Tiefpassfilter f hren kann wenn der digitale Signalprozessor neu konfiguriert wird Die berblendfunktion eliminiert jegliche Klick und Schlagger usche Diese Funktion l sst sich deaktivieren wenn das Ger t unter Live Bedingungen verwendet wird und geringe Parameter nderungen w hrend des Live Auftritts unmittelbar m glich sein sollen Die folgende Abbildung zeigt dass die berblendfunktion abgeschaltet Off und somit deaktiviert wurde Software Version Diese Seite erm glicht die Best tigung der Software Version die auf dem DEQ 230 l uft Software Version Die Bedienungsanleitung basiert auf der Software Version V1 01 10 Untermen Program Utilities Dieses Untermen bietet verschiedene Optionen die sich auf die Betriebsart des DEQ 230 beziehen und erm glicht eine Verwaltung der im Ger t gespeicherten und abrufbaren Voreinstellungen Program Utilities Durch Bet tigung der Taste ENTER und des Drehknopfs NAV PAR1 gelangt man auf die folgenden Seiten Recall a
60. ng the 3 encoders they are automatically Saved as current and stored in the DEQ 230 system status once leaving the page Note2 to exit this page push the ESC button Note3 the led meters on top of the LCOMP and RCOMP buttons are indicating the Limter s activity showing from top to down the output signal limitation in dBu 56 e MENU A B Output Channels Utilities Access by pushing the LOUT ROUT buttons From the Default Screen it is possible to access the Equalizer s Channel Utilities menu by pressing the LOUT or ROUT button Once pressed the related blue EDIT LED will turn ON The Sub Menus pages can now be scrolled through by rotating clockwise and counter clockwise the NAV PAR1 encoder The available utilities are the following 1 Flat Equalizer 2 Copy Equalizer from Ch x 3 Set Eq as graphic mode The previous utilities can be just confirmed by ENTER and automatically the related process will take place after a confirmation request Flat Equalizer this utility is allowing to clear the all filters of the related Equalizer s Channel If selected the Equalizer s Channel A named Left the screen will be the following Pushing ENTER again the DEQ 230 will clear the all filters Copy Equalizer from ChX this utility is allowing to on the currently selected Equalizer s Channel the complete setting of the other one If selected the Equalizer s Channel A named Left th
61. nk Equalizer s to Compressor s channels To link channels when editing you will need to select a Master channel that will be the one to be edited and have it s parameters displayed on the LCD screen You can then select and link the other channel Slave that you wish to apply the same changes to To enter a link mode session select the Master channel Edit mode then link the Slave by pressing their related Edit buttons Once Linked the channels will be selected ready for adjustment when their Blue LED is lit in the Editing mode Now the Slave channel will modify its parameters accordingly as you edit the Master channel All other existing parameters will stay the same within the Slave Channel unless edited by this link with the Master channel Note The LINK function is NOT a COPY function If we want to edit the Limiter of the Equalizer s Channel A named Left we can enter the editing mode of Compressor s Channel A by pressing the related LCOMP Edit button and turning on the Blue LED below the LCOMP LED meters This assigns the role of Master and displays this channel s parameters on the LCD JutputA 5ms R 0 2s 5 0dB Then press the Edit button of Compressor s Channel B turning ON its related Blue LED s Now all parameters edited on Compressor s Channel A will also be applied to channel B If we want to remove the linked channel from the Link press the related Edit button Exiting the editin
62. ntrol c cccceseenseenees USB RS485 Subject to technical modification If the unit is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment 61
63. ob die Voreinstellung initialisiert wird verf gbar oder noch nicht erstellt B Wenn JA dann schickt der Mikrocontroller dem Benutzer z B Crestron AMX Remote Control den im Befehl verwendeten Rahmen zur ck RX STX ID_M ID_N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 1BH NPreset 00H 00H 00H 00H 00H 00H 00H F7H In diesem Fall d h wenn der Benutzer GENAU das zur ckbekommt was gesendet wurde ist die Voreinstellung vorhanden und auf dem Ger t geladen C Wenn die Voreinstellung die der Benutzer laden wollte NOCH NICHT INITIALISIERT wurde noch nicht erstellt d h nicht verf gbar dann informiert der Mikrocontroller den Benutzer dar ber indem er den folgenden Rahmen zur ckschickt RX STX ID_M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH CIH XX 1BH FFH 00H 00H 00H 00H 00H 00H 00H F7H 30 Regler fur Eingangsverstarkung und Ausgangslautstarke UPDATE GAINS PHASE CMD 01H A Zum ndern der Eingangsverst rkung Kanal 0 1 oder der Ausgangslautstarke Kanal 2 3 muss der Benutzer den unten aufgef hrten Befehl senden zusammen mit dem Wert der Vol zugewiesen werden soll Die Ausgangssignalphase l sst sich ebenfalls ndern TX STX ID M ID N CMD DO D1 D2 D3 D4 D5 D6 D7 ETX FOH C1H XX 01H Chn 00H 00H 00H 00H 00H Phs Vol F7H XX O 31 ID device Chn 0 3
64. ogram Die o a Bildschirmmaske wird ausgeblendet Anmerkung Durch Bet tigung der Taste ESC kann der Aufrufvorgang jederzeit verlassen werden Save a Program Diese Seite erm glicht das Speichern einer neuen Voreinstellung im Speicher des DEQ 230 Durch Bet tigung der Taste ENTER und des Drehknopfs PM2 bzw PM3 lassen sich die zuvor gespeicherten Voreinstellungen und die verf gbaren leeren Speicherpl tze gekennzeichnet mit Empty Memory durchlaufen Wenn keine Benutzervoreinstellungen gespeichert wurden zeigt die Anzeige Save a Program verf gbare Speicherpl tze f r alle Voreinstellungen 09 32 siehe Bespiel unten f r Speicherplatz 10 Zum Speichern einer Konfigurationseinstellung f r den DEQ 230 den Speicherplatz f r eine Voreinstellung aus den 24 verf gbaren Speicherpl tzen mit dem Drehknopf PM2 bzw PM3 ausw hlen Wenn der gew nschte Speicherplatz auf dem Bildschirm erscheint die Taste ENTER bet tigen um auf die Seite Set Program Name zu gelangen Auf dieser Seite kann der Benutzer den Namen einer Voreinstellung bis zu 16 Zeichen eingeben Mit dem Drehknopf PM2 bzw PM3 ein Zeichen ausw hlen und das Zeichen mit dem Drehknopf NAV PAR1 an eine der 16 verf gbaren Stellen positionieren Die aktuelle Position des Cursors wird durch einen blinkenden Unterstrich angezeigt 12 Das folgende Beispiel zeigt eine Bildschirmmaske bei der der voreingestellte Name Velvet Club fur den Spei
65. page Limiter sub menu from this page it is possible to set the Equalizer s Channels Limiter The following is an example screen for the Limiter page where the Attack Time of the Limiter is set at 5ms the Release Time is set at 0 2Sec and the Limiter Active Threshold is set at 5dB A Sms R 0 2s 5 0dB Once pushing ENTER the Limiter s parameters can be modified using the NAV PAR1 PM2 and PM3 encoders for editing the Limiter s Attack Time A Release Time R and Active Threshold Once pushing ENTER the above screen will change as follows The Attack Time A can be edited using the NAV PAR1 encoder the Release Time R the PM2 encoder and the Limiter Active Threshold the PM3 encoder Attack Time A the selectable range of the Limiter s Attack Time is from 5ms to 200ms in steps of 1ms from 5ms to 20ms then 5ms from 20ms to 30ms then 10ms from 30ms to 100ms and 20ms from 100ms to 200ms The Limiter s Attack Time can be adjusted by rotating the NAV PAR1 encoder Release Time R the selectable range of the Limiter s Release Time is from O 1s to 3s in steps of 0 1s and can be adjusted by rotating the PM2 encoder Limiter Active Threshold the selectable range of the Limiter s Threshold is from 20dB Limiter not active to 10 0dB in steps of 0 2 dB and can be adjusted by rotating the PM3 encoder Notei1 once the desired options have been selected usi
66. q 20Hz 20kHz Wenn bei einer Filterverst rkung 0 0 dB ber den Drehknopf PM2 ein Hohenfilter mit Kuhschwanzcharakteristik ausgew hlt wurde und die Flankensteilheit festgelegt wurde 1 Ordnung oder 2 Ordnung 6 dB oder 12 dB l sst sich das H henfilter mit Kuhschwanzcharakteristik mit den folgenden Parametern einstellen Output x Name EQ X bis zu 30 Filter verf gbar gt 1 00kHz 6 12 HiSh 0 0dB Freq 20Hz 20kHz Output x Name Gain Volume 0 0 dB euren d i ESC gt Volume 0 0 dB PAR1 N A BW 0 05 3 00 PM2 N A PM2 N A 12 dB 6 dB Amp 15 0 dB 15 0 dB Amp 15 0 dB 15 0 dB Amp 15 0 dB 15 0 dB Same as PAR2 MENU A B Output Channels Compressor Zugang iiber die Tasten LCOMP RCOMP Drehknopf NAV PAR1 zum Navigieren durch die Ments 1 Output x Name Limiter A 5ms R 0 2s 20dB es fes gt A 5ms R 0 2s 20dB Drehknopf NAV PAR1 Drehknopf PM2 Drehknopf PM3 zum Ausw hlen von Werten f r die Parameter die Werte brauchen nicht best tigt zu werden sie werden w hrend der Bet tigung der Drehkn pfe automatisch geladen Atk time 5ms Rel time O 1s Amp 10 0 dB 200ms 3 0s 20 0dB OFF MEN A B Output Channels Utilities Zugang ber die Tasten LOUT ROUT Drehknopf NAV PAR1 zum Navigieren durch die Men s 1 Output x Name Copy Equalizer from Ch y ENTER f Esc Zur Best tigung
67. r setting will be either bypassed and the Equalizer will enter the FLAT condition or the Equalizer will perform the current setting The red LED will illuminate when the Equalizer s will be flat When the BYPASS LED is OFF then the related Equalizer s Output Channel is performing the current setting When the LCOMP RCOMP buttons are pushed and held for more than one second the Compressor setting will be either bypassed and the Compressor will enter the FLAT condition or the Compressor will perform the current setting The red LED will illuminate when the Compressor will be bypassed When the BYPASS LED is OFF then the related Equalizer s Output Channel Compressor is performing the current setting A momentary push of the LOUT ROUT buttons enters Utilities functions for the Equalizer s Channels see later for the Equalizer s Utilities Functions details The blue UTIL LED will now be ON A momentary push of the LCOMP RCOMP buttons enters the Editing Menu for the Equalizer s Compressor Section see later for the Compressor s Editing details The blue EDIT LED will now be ON DEQ 230 Menu and Sub Menu Structures As stated above the start up default screen is the following factory preset Default Flat From this point sub menus are accessed using the UTILITY LOUT ROUT LCOMP RCOMP ENTER and ESC buttons and all parameters and values are navigated by the NAV PAR1
68. rs Output x Name EQ X up to 30 filters available gt 1 00kHz 6 12 HiSh 0 0dB 10 Output x Name Gain Volume 0 0 dB enter fesc gt Volume 0 0 dB when the filter s gain 0 0dB ONLY through the PM2 it is possible to chose and select between a Bell or a Shelving filter Freq 20Hz 20kHz Freq 20Hz 20kHz Freq 20Hz 20kHz PAR1 N A BW 0 05 3 00 PM2 N A PM2 N A 12 dB 6 dB Amp 15 0 dB 15 0 dB Amp 15 0 dB 15 0 dB Amp 15 0 dB 15 0 dB Same as PAR2 a7 MENU A B Output Channels Compressor Access by pushing the LCOMP RCOMP buttons NAV PAR1 Encoder to navigate between menus 1 Output x Name Limiter A 5ms R 0 2s 20dB enter 4 fesc gt A 5ms R 0 2s 20dB NAV PAR1 Enc PM2 Enc PM3 Enc to chose values for the parameters no need to confirm the chosen values which are automatically loaded during the encoders use Atk time 5ms Rel time O 1s Amp 10 0 dB 200ms 3 0s 20 0dB OFF MENU A B Output Channels Utilities Access by pushing the LOUT ROUT buttons NAV PAR1 Encoder to navigate between menus 1 Output x Name Copy Equalizer from Ch y ENTER ESC Enter to Confirm 2 Output x Name Set Eq as graphic mode enter f esc Enter to Confirm 3 Output x Name Flat Equalizer ENTER f Esc Enter to Confirm NAV PAR1 Enc PM2 Enc
69. screen and press the UTILITY Button to access the following screen to enable the correct password to be entered After the correct password has been entered you will be able to access the full functionality of the DEQ 230 the lock Icon will disappear from the Default Screen and automatically the Enable Password page will be back to the Disable condition If no Password has been set within the DEQ 230 as described in the previous paragraphs the DEQ 230 will not allow you to enable any Password and the choice in the Enable Password will be limited to only the Disable option 48 e Menu LIN RIN Equalizer s Channels Editing access by pushing the LIN RIN buttons From the Default Screen it is possible to access the LIN RIN editing menu by pushing the LIN or RIN button Once the button is pressed the related blue EDIT LED will turn ON The Sub Menu pages can now be scrolled through by rotating clockwise and counter clockwise the NAV PAR1 encoder For parameter editing it is necessary to press ENTER and an arrow will appear on the left of the screen gt Then use the PM2 and PM3 encoders for selecting and setting the parameter values On some parameters that have three independent values you will also need to use the PAR1 encoder e g filter parameter settings Note All parameter editing can be done using the NAV PAR1 PM2
70. sten LIN RIN Vom Startbildschirm aus gelangt man durch Bet tigung der Taste LIN bzw RIN in das Einstellmen LIN RIN Sobald die Taste gedr ckt wird leuchtet die entsprechende blaue LED EDIT auf Durch Drehen des Drehknopfs NAV PAR1 im Uhrzeigersinn bzw entgegen dem Uhrzeigersinn lassen sich jetzt die Untermen Seiten durchlaufen Zum Einstellen der Parameter die Taste ENTER bet tigen Ein Pfeil gt erscheint links auf dem Bildschirm Dann die Parameterwerte mit den Drehkn pfen PM2 und PM3 ausw hlen und einstellen Bei einigen Parametern die aus drei unabh ngigen Werten bestehen muss man den Drehknopf PAR1 zur Hilfe nehmen z B f r Einstellungen der Filterparameter Anmerkung Alle Parameter lassen sich mit den Drehkn pfen NAV PAR1 PM2 und PM3 einstellen Der aktuell angezeigte Wert der ausgew hlten Option wird bei Bet tigung der Drehkn pfe AUTOMATISCH geladen und beim Verlassen der Seite als aktueller Wert abgespeichert Blockdiagramm f r die Audiosignal Kanale des Equalizers LIN RIN i S PDIF Left TER S PDIF Right u ac Hel pee ere trba ives fessa nere usas ji a e i f J e Name page Diese Seite erm glicht es dem Kanal des Equalizers einen aus 6 Zeichen bestehenden Namen zuzuweisen Die Beispielseite unten zeigt eine Bildschirmmaske mit der Bezeichnung Left fur den Equalizer Kanal LIN A Zum Einstellen die Taste ENTER auf dieser Seite bet
71. t all With this option when trying to access a parameter the following screen message will appear Lock Unit this sub menu allows the user to lock the device so no parameters can be edited or modified When the Unit is in an unlocked condition all parameters will be available for editing When you select On all parameters will be locked and are not available for editing When you select lock from the menu the unit will be locked and the lock menu automatically exited The screen will revert to the Default showing the current Equalizer s preset selected and beside the preset s name a keylock icon indicating that the DEQ 230 is locked 46 User Password from the User Password sub menu Using the PM2 or PM3 encoders to choose a character and the NAV PAR1 encoder to move between available locations you can enter a 6 Character Password Name The current position of the cursor for the characters to be entered is shown by a blinking underscore During this editing phase the display is as follows if we were using DEQ230 as the password The DEQ 230 will exit the Unit Lock sub menu and jump to the User Password sub menu page screen Insert Password If the password entered in the Confirm Password page matches the one entered in the Enter Password page the following screen will appear The Password is now configured and held in the device s memory Th
72. t des Initialisierungsvorgangs des DEQ 230 Der DEQ 230 verf gt ber 8 Voreinstellungen Default Flat Default Classic Default Disco Default Jazz Default Pop Default RnB Default Rock und Default Vocal Nach der Initialisierung erscheint auf der LCD Anzeige des DEQ 230 die erste Voreinstellung bzw die Voreinstellung die zuletzt gew hlt wurde bevor das Ger t abgeschaltet wurde Bei der ersten Inbetriebnahme erscheint die erste Voreinstellung DEQ 23C Default Flat Nachstehend erfolgt eine Beschreibung der Funktionen der Bedienelemente auf der Vorderseite des DEQ 230 e Drehkn pfe und Tasten ENTER ESC Der DEQ 230 verf gt ber 3 Drehkn pfe NAV PAR1 PM2 und PM3 Diese Drehkn pfe erm glichen die Navigation durch die Benutzeroberfl chke und die Einstellung der Prozessorbereiche Mit Hilfe dieser Drehkn pfe kann der Benutzer durch den Bildschirm navigieren und auf diese Weise Untermen s Seiten und Parameter sowie die Werte ausw hlen die bei den Einstellschritten zugewiesen werden sollen Die Tasten ENTER und ESC dienen zur Best tigung oder zum Abbruch der mit den Drehkn pfen vorgenommenen Einstellungen e Tasten UTILITY LIN RIN und LOUT ROUT LCOMP RCOMP Mit der Taste UTILITY gelangt der Benutzer in die Untermen s um die allgemeinen Einstellungen des Equalizers vorzunehmen Die Tasten LIN und RIN erm glichen dem Benutzer in die Einstellmen s f r die Eingangskan le der Equalizers zu gelangen oder die Ausg
73. tigen Der Eingabepfeil erscheint wie im Beispiel unten Die erste Zeichenstelle blinkt Die Position des Zeichens mit dem Drehknopf NAV PAR1 aus dem 6 verf gbaren Zeichen ausw hlen dann das gew nschte Zeichen mit dem Drehknopf PM2 bzw PM3 ausw hlen 19 Zum Best tigen des ausgew hlten Namens die Taste ENTER bet tigen Der neue Name wird gespeichert Das Beispiel unten zeigt das Ersetzen des bisherigen Namens Left durch CHI A J Zum Einstellen die Taste ENTER auf der Seite NGate bet tigen Der Eingabepfeil erscheint wie im Beispiel unten Noise Gate Die Parameter f r die Rauschsperre Ansprech R ckstellzeit und Schwellwert lassen sich ber die PC Software bearbeiten und einstellen Source page Diese Seite erm glicht es einen der folgenden Eing nge einem beliebigen Equalizer Kanal zuzuweisen Analog InA Input Channel A Analog InB Input Channel B Analog InA B Sum of Input Channel A 2 Input Channel B 2 Digital Left Input S PDIF Channel Left Digital Right Input S PDIF Channel Right Digital L R Sum of Input S PDIF Channel Left 2 Input S PDIF Channel Right 2 Se ae Das Beispiel unten ist eine Bildschirmmaske f r die Signalquelle Source in der Analog Input A dem Equalizer Kanal A mit der Bezeichnung Left zugewiesen wurde Nach Bet tigung der Taste ENTER erscheint links auf dem Bildschirm ein Pfeil gt Der Eingang l sst sich mit dem Drehknopf PM2
74. tzen muss steht dem Benutzer eine Funktion zur Verf gung die s mtliche Einstellungen des DEQ 230 zur cksetzt und das Ger t auf die urspr ngliche Werkseinstellung zur ckstellt Anmerkung Die Fortsetzung dieses Vorgangs f hrt dazu dass der DEQ 230 eine Reinitialisierung auf die urspr ngliche Werkseinstellung vornimmt Alle zuvor gespeicherten Informationen und Anderungen gehen dabei unwiderruflich verloren Zum Zur cksetzen auf die Werkseinstellung wie folgt vorgehen 1 Bei ausgeschaltetem DEQ 230 gleichzeitig die Tasten ENTER ESC UTILITY auf der Vorderseite bet tigen 2 Alle drei Tasten gedr ckt halten und gleichzeitig den Netzschalter auf ON stellen Die folgende LCD Anzeige erscheint auf dem DEQ 230 Memory Reset 3 Die Tasten l sen und solange warten bis der DEQ 230 die Reinitialisierung vornimmt Nach Beendigung nimmt der DEQ 230 den normalen Betrieb wie ein fabrikneues Ger t wieder auf Zuvor programmierte Parameter stehen dann nicht mehr zur Verf gung e Groundlift Schalter Auf der R ckseite des DEQ 230 befinden sich Massetrennschalter mit denen eine Verbindung zwischen dem Schutzleiter der Stromversorgung sowie der Masse der Schnittstellen zur Geh usemasse hergestellt bzw getrennt werden kann Schalter MAIN LIFT GND Um Masseschleifen zu vermeiden kann es manchmal erforderlich sein die Signalmasse von der Geh usemasse zu trennen Das erm glicht der Schalter GND LIFT Wenn der Schalter in
75. uf Einstellfunktionen f r das Ger t Im Locked by Password Status werden alle Funktionen des DEQ 230 f r den Anwender gesperrt einschlie lich der Bet tigung der Stummschaltungstasten LIN RIN und der Bypass Tasten LOUT ROUT LCOMP RCOMP Der einzig m gliche Zugang besteht zu den Parametern der Eingangs Ausgangskan le durch Bet tigung der Taste EDIT lediglich um die Werte zu lesen keine Einstellung m glich wenn die Markierung be shown im Untermen Show Parameter ausgew hlt wurde Sobald die Funktion Locked by Password aktiviert wird erscheint das Sperrsymbol auf dem Startbildschirm Es besteht kein Zugriff auf Men seiten au er auf die Option User Password Um Zugriff auf die volle Funktion des DEQ 230 zu erhalten in die Bildschirmmaske User Password gehen dann die Taste UTILITY bet tigen damit das richtige Passwort eingegeben werden kann Nach Eingabe des richtigen Passworts besteht Zugriff auf die gesamte Funktionsvielfalt des DEQ 230 Im Startbildschirm erlischt das Sperrsymbol und die Seite Enable Password wird auf den Status Disable deaktivieren zur ckgestellt Wenn im DEQ 230 kein Passwort eingestellt wurde wie oben beschrieben l sst sich kein Passwort f r den DEQ 230 aktivieren Die Auswahl bei Enable Password beschr nkt sich dann lediglich auf die Option Disable 18 e Men LIN RIN Einstellung der Equalizer Kanale Zugang uber die Ta
76. utzer die Auswahl von Bell oder Shelving Parametern und deren unabh ngige Zuweisung mit Hilfe der 30 verf gbaren Filter Um den Filtertyp auszuw hlen muss die Verst rkung der Filter 0 0 dB betragen Dann den Drehknopf PM2 im Uhrzeigersinn drehen um die Bandbreite des Bell Filters festzulegen bzw gegen den Uhrzeigersinn drehen um den Typ des Kuhschwanzfilters Tiefenfilter oder H henfilter sowie dessen Ordnung 1 Ordnung oder 2 Ordnung auszuw hlen Um den Filtertyp f r Filter Nr 1 x 1 zu definieren von der o a Bildschirmmaske durch Bet tigung der Taste ENTER auf die Einstellseite f r das Filter gehen Die folgende Bildschirmmaske erscheint gt 1 00KHz BW1 05 0 0dE In diesem Fall betr gt die Verst rkung des Filters 0 0 dB und die Bandbreite 1 05 Das aktuell gew hlte Filter ist vom Typ Bell Nach Drehen des Drehknopfs PM2 im Uhrzeigersinn liegt der Bandbreitenparameter zum Festlegen eines Bandbreitenwertes f r ein Bell Filter zwischen 0 05 und 3 Wenn ein Bell Filter ausgew hlt wurde kann die Verst rkung ab 0 0 dB und die Bandbreite von 0 05 bis 3 modifiziert werden Zum Ausw hlen eines Kuhschwanzfilters mit der Verst rkung 0 0 dB aus der o a Einstellung falls die Verst rkung nicht 0 0 dB betr gt diese mit dem Drehknopf PM3 auf 0 0 dB einstellen den Drehknopf PM2 entgegen dem Uhrzeigersinn drehen Sobald die Bandbreite den Wert 0 05 erreicht wird beim n chsten Schritt der Drehung des Drehknopfs entgege
Download Pdf Manuals
Related Search
Related Contents
Weider 8530 SYSTEM 15927 User's Manual Rose RE2-1R2X16U/2 KVM switch Adesso 8118-01 Instructions / Assembly AP32288 - XMC1000/XMC4000 - Capture Compare Unit 8 "user manual" StockTrade Client User Manual Demonstrating the SMV 3000 as a Flow Transmitter with the SCT Samsung Galaxy Tab Manual de Usuario(LTN) Copyright © All rights reserved.