1. Installing the mounting plate QG Select appropriate screws for wall material See p 55 Appendix for details Tentatively fasten one screw in the top center hole of the mounting Screw plate tentatively fasten 3 Q The screw should be perpendicular to the wall Hang the mounting plate on the ten tatively fastened screw Adjust the mounting plate vertically Tighten six screws in the remaining mounting holes to fix the plate on the wall Tighten the tentatively fastened screw E Make sure that the mounting plate is on the level 40 lt Mounting the PV Inverter gt 1 Remove two screws from the bottom of the PV inverter MM gt PV inverter 1 Securely place the overhang in the upper section of the back of the PV inverter into the groove of the mount ing plate 2 Fix the PV inverter on the mounting plate with two screws which were removed in 1 1 Tightening torque 1 4 1 6 Mounting Screw plate 41 8 Connecting Cables 8 1 PV Module DC Input Connection Perform the following procedure before con necting the DC input to the PV inverter 1 Check polarities and maximum voltage of each PV module string Very dangerous high direct current voltage is present on the PV module Follow safety precautions to the fullest 2 Make sure that AC and DC disconnectors are off Take care not to allow to turn on the and DC disconnectors unexpec
2. 10 3 Tie up the tube with the cable tie with the DC cable held therein 4 Fix the DC cable on the terminal Tightening torque 2 6 3 4 N m Avoid confusing the DC with the DC cable G Ensure that the protective tube is installed This is required to prevent the cable from being damaged or arrest the spread of possible fire Cord clip Cable tie Protective tube For DC cables lt 6mm 1 Remove the cord clip 2 Run the DC cables in a bundle through the protective tube 20 DC terminal DC terminal 3 Install the DC cables on the terminal Tightening torque 1 4 1 6 N m G Avoid confusing the DC with the DC cable 4 Fasten the cord clip around the protec tive tube in which the cables are held Tightening torque 2 6 3 4 N m G Ensure that the protective tube is installed This is required to prevent the cable from being damaged or arrest the spread of possible fire 44 Fasten the DC cable glands DC terminal DC terminal Tightening torque 3 Avoid exerting tension on the cables Turn on the DC disconnector and then check for the correct voltage between terminals DC and DC on the DC input terminal DC terminal DC terminal Make sure that the protective cap remains on the unused cable gland Turn off the DC disconnector 45 8 2 Connection of AC Output Perform the following procedure before connecting the PV inverte
3. en Sie das Massekabel fest an Ein Brand oder ein Stromschlag k nnen die Folge sein Tragen Sie bei den Verkabelungsarbeiten des Wechselrichters isolierte Gummihandschuhe f r Niederspannungen Sonst kann es zu einem Stromschlag kommen Pressen Sie die Kabel sen mit dem erforderlichen Druck auf die Stromkabel Ein Brand kann die Folge sein 3 Erscheinungsbild 3 1 Abmessungen 3 2 Interner Aufbau lllBefestigungsbohrungen 289 4X p7 Ma einheit mm Die nachstehende Abbildung zeigt den internen Aufbau und die Anschl sse bei abgenommener Frontplatte D Drosselbereich 2 Reglerbereich 3 Klemmenleiste DC 4 Klemmenleiste DC 5 Klemmenleiste AC Ausgang 6 Masseanschluss 7 AC Kabelverschraubung DC Kabelverschraubung 9 DC Kabelverschraubung Modulare Buchse f r Kommunikationsleitung optional 17 Kabelverschraubung Kommunikationsleitung optional 4 Zubeh r und Teile Der PV Inverter PV PNSO4ATL GER PV PNSO6ATL GER wird mit dem fol genden Zubeh r und den nachstehenden Teilen ausgeliefert Pr fen Sie die Lieferung anhand der nachstehenden Liste auf Vollst ndigkeit D Solarstrom Wechselrichter 8 Schutzrohr o 20 x3 Q 4 Schutzrohr 10 x6 O 5 2 Montageplatte Kabelbinder x7 Bedienungsanleitung Installationshandbuch Kabellehre Nr Kabelbinder Bedienungsanleitun
4. Conductor cross section 2 5 10mm External diameter 4 5 10mm 95 2 AC Cable AC cables should meet the following specifications Cables suited to the maximum output of the PV modules you are connecting should be selected o PV PNSO4ATL GER PV PNSO6ATL GER Grid 230 VAC 15 2 Max 21 7A Configuration Conductor cross section 2 5 10mm External diameter 11 20mm None 11 3 Crimping Terminals and Crimping Tools Crimping terminals suited to the diameter of the cable conductor should be applied Typical terminals include the following Manufacturer Tyco Electronics Corporation Conductor cross section Crimping terminal type Crimping tool type 6 10 5mm 170728 1 4097 79 1 2 6 6mm 171519 2 409780 1 171517 1 409776 1 The terminal built in the inverter is available to the crimping terminals of the following dimensions Dimensions of the applicable head of the crimping terminal Applicable range Crimping terminal oD z5imm Wi p D 56 s MITSUBISHI ELECTRIC CORPORATION s MITSUBISHI ELECTRIC CORPORATION Aug 2006
5. PNSO4ATL GER PVPNSOGATL GER Im Folgenden wird die Installation des Wechselrichters beschrieben lt Montage der Montageplatte gt W hlen Sie die Schrauben nach den f r die Wand verwendeten Materialien Details finden Sie im Anhang auf Seite 27 1 Drehen Sie die Schrauben in die i li obere mittige Bohrung der Montageplatte ziehen sie aber noch angezogen 3 nicht fest Die Schraube muss senkrecht zur Wand ausgerichtet sein H ngen Sie die Montageplatte auf die Schrauben Justieren Sie die senkrechte Ausrichtung der Montageplatte Drehen Sie jetzt auch die restlichen sechs Schrauben in die jeweiligen Montagebohrungen Ziehen Sie jetzt die Schrauben fest an Vergewissern Sie sich dass die Montageplatte waagerecht ausgerichtet ist 12 lt Montage des Wechselrichters gt 1 Entfernen Sie die beiden Schrauben unten am Wechselrichter Solarstrom Wechselrichter 1 F hren Sie die Falz im oberen Bereich der R ckseite des Aufh ngung Wechselrichters in die Nut der Solarstrom Montageplatte Hierdurch wird der Wechselrichter Wechselrichter von der Montageplatte gehalten 2 Befestigen Sie den Wechselrichter mit den in 1 1 entfernten Schrauben auf der Montageplatte Drehmoment 1 4 1 6 N m Montageplatte Schraube 13 8 Anschlusskabel 8 1 Solarzellenanschluss DC Eingang Gehen Sie beim Anschluss des DC Eingangs des Wechselrichters wie folgt vor 1 Pr fen Sie
6. automatisch auf der LCD angezeigt Dies bedeutet dass Sie schnell ber jeden Fehler des Wechselrichters und zus tzlich ber Fehler bei der Installation des System und des Wechselrichters informiert werden Symptome Pr fen Aktion Auf der LCD Die von den Solarzellen kom wird keine mende Spannung ist nicht korrekt Information an die DC Klemmenleiste des angezeigt Wechselrichters angeschlossen Der DC Trennschalter ist aus geschaltet Auf der LCD Pr fen Sie ob auf der LCD eine wird eine Fehlermeldung oder ein Fehlermeldung SToERUNG Exx Fehlercode angezeigt wird und angezeigt oder s wenden Sie sich an Ihren die FEHLER H ndler LED leuchtet Wird einer der folgenden Fehler angezeigt folgen Sie den Anweisungen Fehler Beseitigung Netz defekt oder Pr fen Sie ob die Spannung falsch zwischen den Klemmen L und N angeschlossen bei 184 264 V AC liegt Ist die Spannung nicht korrekt pr fen Sie die Verkabelung Stromausfall des Pr fen Sie ob der AC Netzes oder der Trennschalter ausgeschaltet ist ist nicht eingeschaltet 23 Fehler Beseitigung Spannung Es sind zu viele Solarzellen in h her als 700 V Serie geschaltet Konfigurieren STOERUNG E 20 DC Sie die Solarzellen um Massefehler Pr fen Sie ob Solarzellen und aufgetreten Verkabelung korrekt isoliert sind Pr fen Sie ob das Netz korrekt an die Klemmen L und N angeschlossen ist Schlechte Der S
7. die Polung und die maximale Spannung der Solarzellen Strings An den Solarzellen liegt eine gef hrlich hohe Gleichspannung an Befolgen Sie unbedingt die erforderlichen Sicherheitsvorkehrungen 2 Pr fen Sie ob die Trennschalter f r AC und DV AUSGESCHALTET sind Sorgen Sie daf r dass w hrend der Arbeiten AC und DC Trennschalter nicht wieder eingeschaltet werden k nnen Folgen Sie den nachstehenden Anweisungen um die von den Solarzellen kommenden Kabel anzuschlie en DC Eingang D Entfernen Sie die beiden Schrauben mit denen die Frontplatte unten befestigt ist 2 Nehmen Sie die Frontplatte ab L sen Sie auch das Massekabel von der Frontplatte Nehmen Sie das isolierte Teil des Massekabels und ziehen es in die abgebildete Richtung 4 Schraube Pr fen Sie den Kabelquerschnitt des DC Kabellehre Kabels mit Hilfe der Kabellehre Schieben Sie das DC Kabel durch die ffnung in der Kabellehre Hierdurch sehen Sie ob der Kabelquerschnitt gr er oder kleiner als 6 mm ist Anschlussmethoden f r DC Kabel andere Kabelquerschnitte finden Sie auf Seite 16 6 Klemmenleiste Klemmenleiste DC Kabelverschraubung kleinerer Durchmesser F hren Sie das Kabel der Solarzellen DC Eingang vom DC Trennschalter durch die DC Kabelverschraubung kleinerer Durchmesser in den unteren Bereich des Solarstrom Wechselrichters X Sollen mehrere Kabel hin durchgef hrt werden l sen Si
8. enbereich wie auf einer Seite offene Garagen montiert werden Der Montageplatz muss durch T ren gesichert sein Montieren Sie den Wechselrichter waagerecht an einer Wand die das Gewicht des Ger ts tragen kann Ist die Wand nicht stark genug verst rken Sie die Wand vor der Installation PV PNSO4ATL GER wiegt 19 kg PV PNSO6ATLGER 20 kg einschl Montageplatte Sie auf Seite 27 Umgebungstemperatur 25 60 C Relative Feuchte 30 90 Montieren Sie den Wechselrichter im Geb ude an einer Stelle an der keine Kondensatbildung durch Temperaturschwankungen auftreten kann Vermeiden Sie direkte Sonneneinstrahlung Durch sehr hohe Temperaturen kann die Leistung sinken Montieren Sie den Wechselrichter an einem Ort der tiefer als 1 500 m unter Normal Null liegt Sorgen Sie um den Wechselrichter f r ausreichenden Platz damit die K hlung optimal ist und er einfach gewartet werden kann Bei einer Installation von mehreren Inverter finden Sie entsprechende Details auf Seite 10 a Ir 50 oder mehr Vorderseite 1 000 oder mehr 500 bis 2 000 Ma einheit mm N ACHTUNG Installieren Sie den Wechselrichter nicht unter folgenden Bedingungen Anderenfalls kann der Wechselrichter herunterfallen oder rein sicherer Betrieb ist nicht m glich Au erdem kann die Garantie verfallen Au en oder Au enbereiche NICHT in Bereichen wie auf einer Seite offene Garagen montiert der Monta
9. 0607874HC4901 MITSUBISHI ELECTRIC PHOTOVOLTAIC INVERTER MODEL PV PNSO4ATL GER PV PNSO6ATL GER Installationshandbuch Deutsch pp 1 28 Installation Manual English pp 29 56 MITSUBISHI A ELECTRIC SOLARSTROM WECHSELRICHTER MODEL PV PNS04ATL GER PV PNS06ATL GER Installationshandbuch Der Solar Wechselrichter PV Inverter PV PNSO4ATL GER PV PNSO6ATL GER entspricht den Anforderungen der DIN VDE 0126 1 1 Daher der dieser Wechselrichter nur in L ndern verwendet werden in denen diese Richtlinie gilt Inhaltsverzeichnis Seite eaa a ya pu ban nern sk EE 3 2 Sicherheitshinwelse a quus que iex mon EE oe de PO 4 3 ErSchemundsbil l Bent ete beware e 5 3 1 ADmessungen teen 5 3 2 Interner Aufbau 3 2 22222 XE 3 E bebe dhe 5 Za Zubehoer und Tele arena 224 446 eee 6 5 Erforderliche Teile Ausr stung und Werkzeuge 7 G AMOdETUNGEN ses ne reame ae near E ehe a 8 11 InsralalellbolE usa haan ne fae eee ek seiten ri 8 10 6 2 Anschluss an Solarzellen 11 6 3 Anschluss an ein Netz 11 7 Installation des Solarstrom Wechselrichters 12 19 PV PNSO4ATL GER PV PNSO6ATL GER 8 Anschlusskabel us ower ee Ree ee ee ee aaa a a
10. C und das Klemmenleiste Massekabel PE durch das AG AUSgANG Schutzrohr 20 und befestigen Sie die Kabel L und N an die Klemmen L und N der Klemmenleiste des AC Ausgangs Schutzrohr Verwechseln Sie nicht die Phasen L und N Drehmoment 2 6 3 4 N m 18 Schlie en Sie das Massekabel PE an die Klemme rechts neben der Klemmenleiste des AC Ausgangs des Wechselrichters an Drehmoment 0 9 1 1 Befestigen Sie das Schutzrohr mit den AC Kabeln mit einem Kabelbinder Befestigen Sie die AC Kabelverschraubung Drehmoment 5 N m Schalten Sie den AC Trennschalter EIN und pr fen Sie die Spannung zwischen den Klemmen L und N auf der Klemmenleiste des AC Ausgangs 8 3 Nach dem Anschluss der Kabel Befestigen Sie die und DC und Kabelverschraubungen damit sie fest verschlossen sind D Haken Sie die Frontplatte des Frontplatte Wechselrichters wieder ein Schlie en Sie das Massekabel wieder an den Masseanschluss unter der Frontplatte an S Masseanschluss Schlie en Sie die Frontplatte ohne etwas einzuklemmen 2 Befestigen Sie die Frontplatte auf der Unterseite mit den beiden Schrauben Schraube 20 9 Probelauf Im Folgenden wird der Probelauf des Wechselrichters beschrieben 9 1 Tests vor Inbetriebnahme Die AC Kabel wurden korrekt angeschlossen Alle DC Kabel von den Strings wurden angeschlossen Au erdem sind alle nicht benutzten Kabelverschra
11. Spezifikationen entsprechen Das Kabel muss entsprechend der Ausgangsleistung der Solarzellen ausgew hlt werden PV PNSO4ATL GER PV PNSO6ATL GER Netz 230 V AC Max 15 2A Max 21 7A Konfiguration Leiterquerschnitt 2 56 10mm Au endurchmesser 11 20mm ER 11 3 Kabel sen und Werkzeuge Es m ssen Kabel sen die dem Kabelquerschnitt entsprechen ausgew hlt werden Nachfolgend finden Sie entsprechende Kabel sen Hersteller Tyco Electronics Corporation Die Klemmenleisten in dem Wechselrichter sind f r folgende Kabel sengr en ausgelegt Abmessungen der entsprechenden Kabel sen Anwendungsbereich Kabel se m i pD 28 MITSUBISHI A ELECTRIC PHOTOVOLTAIC INVERTER MODEL PV PNS04ATL GER PV PNS06ATL GER Installation Manual The photovoltaic inverter PV inverter PV PNSO4ATL GER PV PNSOGATL GER is designed to the regulations stipulated in DIN VDE 0126 1 1 Therefore the owner may use the PV inverter only in countries or areas where such regulations are applicable Table of Contents Page 1T Ae lr e aalt et el DEE 2972777 7 0 7 0111271227 er W ee 31 2 Sale EE a qos ser ser ae vox ei nme 32 3 e 422 Chat G aes EE E re ee ee 33 371 DIMENSION ba ee Bu W REUS a ee es 33 3 2 Internal COMIQUIALION e ge ed et 33 4 Included Components and Parts 34 5 Require
12. ch damit das Kabel nicht besch digt wird und Feuer sich nicht ausbreiten kann 16 Befestigen Sie die DC Kabelverschraubung Drehmoment 3 N m Q Achten Sie darauf dass auf das Kabel kein Zug ausge bt wird Schalten Sie den DC Trennschalter EIN und pr fen Sie die Spannung zwis chen den Klemmen DC und DC auf der Klemmenleiste des DC Eingangs Achten Sie darauf dass die Schutzkappen an den nicht verwendeten Kabelverschraubungen vorhanden sind Schalten Sie den DC Trennschalter AUS 17 8 2 Anschluss AC Ausgang Gehen Sie beim Anschluss des Wechselrichters an den DC Ausgang wie folgt vor 1 Pr fen Sie das Netz auf korrekte Spannung berzeugen Sie sich dass die Spannung zwischen 184 und 264 V liegt 2 Pr fen Sie ob die Trennschalter f r AC und DV AUSGESCHALTET sind Sorgen Sie daf r dass w hrend der Arbeiten der Stromfluss nicht wieder eingeschaltet werden kann Gehen Sie beim Anschluss des AC Kabels an den Wechselrichter wie folgt vor 1 F hren Sie das AC Kabel durch die s AC Kabelverschraubung gr rer Durchmesser in den unteren etwa 1 mm Pressen Sie auf die Markierung Bereich des Solarstrom SEES 7 Wechselrichters und bringen dann L I eine Kabel se 5 an 2 Bringen Sie die beiliegende Kabel se p 4 an das Massekabel PE an Verwechseln Sie nicht AC und DC AC Kabelverschraubung Kabel gr erer Durchmesser Litze F hren Sie die A
13. ct current sides before performing maintenance Always wait for 30 minutes to discharge the capacitors built in the PV inverter before opening its front panel Electric shock may result Connect the earth lead securely Fire or electric shock may result Important Wear insulated rubber gloves for low voltage operations when wiring PV inverter Electric shock may result Securely press fit to tighten crimp terminals with specified torques on lead wires Fire may result 32 3 Appearance 3 1 Dimensions ocation of mounting holes 289 4X 7 Unit mm 3 2 Internal Configuration The figure below shows the internal configuration and connections with the front panel removed D Reactor area 2 Controller area DC terminal 4 DC terminal 5 AC output terminal 6 Earth terminal 7 AC cable gland DC cable gland 9 DC cable gland Modular jack for communications line optional QD Communications line optional gland 4 Included Components and Parts The PV inverter PV PNSO4ATL GER PV PNSO6ATL GER should be pack aged with the following components and parts Please use the following table to make sure that all items are included CD PV inverter 8 Protective tube 20 x3 4 Protective tube 10 x6 O 5 2 Mounting plate 5 Cable tie x7 Operation Manual Q Installation Manual i Cable Dia
14. d Components Equipment and Tools 35 EIERE oase a sinn sasa ae ern ner nee un den m ee as 36 39 6 1 Installation LOCATON serea seek 44 so h s e aan 36 38 6 2 Requirements for Connection to PV Module 39 6 3 Requirements for Connection to Grid 39 Installing PV IDnVellel EE EE EE NEE bos Bene EE ER 40 41 PV PNSO4ATL GER PV PNSO6ATL GER 8 Connecting Cables xus dE Gry x kk ass 42 48 8 1 PV Module DC Input Connection 42 45 8 2 Connection of AC Outp t ax serre sense 46 47 8 3 Actions After Connection 48 9 Feel Sy EE 49 52 9 1 Check Before Turning OR aa ss ss sassa ss es o e ana 49 9 2 Test Run Procedure 49 50 9 9 Troubleshooting ses 425 ngon asses EE 51 52 10 Precautions for 53 54 Appendie ua as LI a ee Ee Eh eg 55 56 11 1 Selecting SEIEWS usss EE pede een 55 11 2 Selecting 55 56 11 3 Crimping Terminals and Crimping Tools 56 30 1 Introduction V S A P The PV inverter PV PNSO4ATL GER PV PNSO6ATL GER converts direct current energy generated by PV modules into alternating current energy for supplying the grid This In
15. e zun chst die Kabelverschraubung und entfernen dann die Schutzkappe DC Kabel DC DC Kabel Kabelverschraubung schwarz DC Kabelverschraubung Bees silbergrau Versehen Sie die DC Kabel mit Kabel sen 5 die dem Kabeldurchmesser entspricht Siehe Anhang Seite 27 15 F r DC Kabel gt 6 mm 1 Entfernen Sie die Kabelklemme 2 Ziehen Sie das DC Kabel durch das Schutzrohr 10 Befestigen Sie das Rohr mit dem DC Kabel mit Hilfe eines Kabelbinders Schlie en Sie das DC Kabel an die Klemmenleiste an Drehmoment 2 6 3 4 N m Achten Sie darauf dass das DC nicht mit dem DC Kabel vertauscht wird Vergewissern Sie sich dass das Schutzrohr installiert ist Dies ist erforderlich damit das Kabel nicht besch digt wird und Feuer sich nicht ausbreiten kann Klemmenleiste Klemmenleiste Kabelklemme Kabelbinder Schutzrohr Kabelklemme F r DC Kabel lt 6mm 1 Entfernen Sie die Kabelklemme 2 Ziehen Sie das DC Kabel durch das Klemmenleiste Klemmenleiste Schutzrohr 20 3 SchlieBen Sie das DC Kabel an die Klemmenleiste an Drehmoment 1 4 1 6 m Achten Sie darauf dass das DC nicht mit dem DC Kabel vertauscht wird 4 Befestigen Sie die Kabelklemme wieder so dass das Schutzrohr mit dem Kabel gehalten wird Kabelklemme Drehmoment 2 6 3 4 Vergewissern Sie sich dass das Schutzrohr installiert ist Dies ist erforderli
16. erdende W rme die Leistung von B beeintr chtigen Seitlicher Abstand zwischen den Wechselrichtern Senkrechter Abstand zwischen den Wechselrichtern Ma einheit mm 10 6 2 Anschluss an Solarzellen An den Wechselrichter k nnen bis zu drei Strings angeschlossen werden Achten Sie darauf dass die Gr e und Spezifikationen der Solarzellen die Sie an den DC Eingang anschlie en den Anforderungen des Wechselrichters entsprechen Aktive Module m ssen den folgenden Gleichstromspezifikationen entsprechen DC Eingang Maximale Spannung je String 700 V DC Minimale Spannung je String 150 VDC Max Strom Summe aller Strings 18 ADC Zur sicheren Arbeit bei Installation und Wartung muss zwischen dem Wechselrichter und den Solarzellen immer ein DC Trennschalter ange bracht sein 6 3 Anschluss an ein Netz Bei dem Anschluss des Wechselrichters an das Netz m ssen die entsprechenden rtlich geltenden Vorschriften und Regelungen beachtet werden Achten Sie darauf dass das Netz an den Sie den Wechselrichter anschlie en die folgenden Anforderungen erf llt Spannungsbereich 184 264 V Frequenzbereich 49 8 50 2 Hz Es m ssen Kabelquerschnitte die der Kabell nge entsprechen verwen det werden um den Leistungsverlust auf ein Minimum zu reduzieren Zwischen dem Netz und de Wechselrichter muss immer ein AC Trennschalter vorgesehen werden 7 Installation des Solarstrom Wechselrichters PV
17. ff disconnector 51 LCD Eror Remedy Voltage higher than 700 VDC is fed ERROR E 20 Earth fault is experienced ERROR E 29 Poor connection on the termi nal s has burnt out the thermal fuse Insufficient volt age is fed to the PV inverter or the DC discon None nector s is off ERROR E 35 Too many PV modules are con nected to each other in series Adjust the number of modules to a proper level Check that both the PV modules and wiring are properly isolated Make sure that the grid is correct ly connected to terminals L and N The PV inverter must be fixed Contact your dealer No information is displayed when the PV modules are not receiving light such as in the morning or nighttime This is normal Make sure that DC cables are correctly connected to the terminals and Make sure that the dis connector s is on If the above does not resolve the problem or errors which are not covered here are experienced contact your dealer 52 10 Precautions for Maintenance NWARNING High direct current voltage is applied on the PV inverter from your PV module The front panel of the PV inverter may only be opened by qualified technicians Opening the front panel Turn off the AC disconnector Turn off the DC disconnector Wait for 30 minutes GO This is required for the capacitors built in the PV inverter to discharge D Remove the t
18. g 2 Wait for about 5 minutes until the inverter RUNN I NG becomes active Check whether or not the LCD displays the power generation level 3 Finish the test run Check Action 1 Press the POWER switch for 2 seconds or longer and then make sure that infor mation shown on the left is dis played on the LCD 2 Turn the AC and DC disconnectors off 50 9 3 Troubleshooting The PV inverter has a self diagnostic system built in automatically displaying any failure detected on the LCD This means that the owner can be quickly notified of any failure of the PV inverter itself but will also be informed if the PV system and or PV inverter has been erroneously installed Symptoms LCD Check Action No informa The PV module voltage is not tion is dis properly applied to the DC input played on the terminal of the PV inverter LCD The DC disconnector is off An error mes G Check for any error message sage is dis error code displayed on the LCD played on the ERROR E x and then contact your dealer LCD or the ERROR LED is on If the following error message is displayed follow the instructions Emr Remedy Grid is defective Check that the voltage among or incorrectly terminals L and N falls some connected where between 184 264 VAC If erratic voltage is detected check the wiring for correctness There is a power Check that the AC disconnector outage in the is o
19. g Installationshandbuch dieses Dokument RSC Wechseln 020 5 Erforderliche Teile Ausr stung und Werkzeuge Schaltplan f r ein Zwei Stringsystem String 1 Solarstrom Wechselrichter P Solarzelle L Sung B AC Trennschalter Jr 3E 5 DC Trennschalter B B ID B T ID O der Installation und bei Wartungsarbeiten DC Trennschalter in Ihr System ein DC Kabel Bauen Sie zur Sicherheit bei Massekabel Beizustellende Teile Kabel se 5 f r Klemmenleiste Kabel se o A f r Massekabel _ DCTremscmalter _ ACTremschalter Jooo 9 Befestigungsschrauben W hlen Sie die Schrauben nach den f r die Wand ver Wechselrichter wendeten Materialien Details finden Sie auf Seite 27 Zubeh r und Werkzeuge f r Elektroarbeiten mag L _ Zage reuzschlitzschraubenzieher rimp Werkzeug nach Herstellerangaben Ausgangs Messinstrument f r mehr als 700 V DC Bereiten Sie alle Teile vor 6 Anforderungen Stellen Sie vor der Installation des Wechselrichters PV PNSO4ATL GER PV PNSO6ATL GER sicher dass die folgenden Anforderungen erf llt werden 6 1 Installationsort Auswahl und Vorbereitung des Montageplatzes Achten Sie bei der Installation des Wechselrichters auf die folgenden Voraussetzungen damit er optimal und sicher arbeitet Installieren Sie den Wechselrichten in einem Geb ude Der Wechselrichter darf NICHT im Au
20. ge open at one side i e no wall or door able to block such side provided Mount the PV inverter horizontally on a firm and sturdy vertical wall strong enough to bear its weight If the wall is not strong enough shore up the wall The PV PNSO4ATL GER weights 19kg PV PNSO6ATL GER 20kg incl mounting plate See p 55 G Ambient temperature 25 60 humidity within 30 9096 Mount the PV inverter inside the building where no possible condensation due to tem perature change occurs Avoid direct sunlight Extremely high temperature deteriorates its performance install the PV inverter at a place lower than 1 500 m above sea level As illustrated below provide enough space around the PV inverter to ensure proper cooling capability and room to facilitate maintenance For installing two or more PV inverter see p 38 Front 000 or wider 4 500 to 2 000 UM 36 N CAUTION Do not install the PV inverter in the following places Otherwise the PV inverter may fail or its safe use may be impeded The product warranty shall also be voided Outdoors or places similar to outdoors It is PROHIBITED to install the PV inverter in places unable to be separated from outdoor environment such as garage open at one side no wall or door able to block such side provided Places where it is exposed to direct sunlight Narrow places lacking ventilation Places where it is exposed to water Places where h
21. geplatz muss durch T ren gesichert sein Stellen mit direkter Sonneneinstrahlung Enge Stellen mit schlechter L ftung Stellen an denen Wasser frei wird Stellen mit sehr hoher Luftfeuchtigkeit wie Waschr ume Stellen mit Dampf lnebel Rauch Staub Salz oder korrosiven Substanzen Stellen mit ld mpfen wie K chen Stellen mit explosiven oder brennbaren Gasen Stellen an denen Vibrationen und St e auftreten Stellen in der N he von brennbaren Materialien Orten mit nicht normalen Betriebsbedingungen die oben nicht beschrieben wurden beispielsweise Schiffe oder Motorfahrzeuge Stellen mit salzhaltiger Luft Installieren Sie den Wechselrichter nicht an den folgenden Stellen Anderenfalls kann der Wechselrichter elektrische St rungen hervorrufen Stellen an denen elektrische St rungen nicht auftreten d rfen Stellen in der N he von Fernseh und Rundfunkger ten oder Kabeln Vorsichtsma nahmen bei der Installation von mehreren Wechselrichtern Installieren Sie die Wechselrichter nebeneinander mit ausreichendem Abstand Da sich eine gr ere Hitze entwickelt als bei der Installation von nur einem Wechselrichter m ssen die Zwischenr ume bel ftet werden Bei der Stromerzeugung gibt der Wechselrichter W rme ab die durch die L ftungs ffnung oder Absaugung an der linken Seite austritt Ist der Wechselrichter B direkt rechts vom Wechselrichter installiert kann die von A freiw
22. ildete Richtung 25 lt Schlie en der Frontplatte gt Pr fen Sie ob die Trennschalter f r AC und DV AUSGESCHALTET sind D Haken Sie die Frontplatte des Frontplatte Wechselrichters wieder ein Schlie en Sie das Massekabel wieder an den Masseanschluss unter der Frontplatte an Masseanschluss Schlie en Sie die Frontplatte ohne etwas einzuklemmen 2 Befestigen Sie die Frontplatte auf der Unterseite mit den beiden Schrauben Schraube 26 11 Anhang 11 1 Schraubenauswahl Wird der Wechselrichter auf einer Wand montiert werden die einzelnen Schrauben mit mindestens 1176 N belastet Die Positionen und die Schraubentypen m ssen entsprechend ausgew hlt werden Es bestehen folgende M glichkeiten 1 F r Holzw nde 5 SE 50mm 48 Plattendicke 2 F r Betonw nde Schraube somm 95mm J MNA en Fischerwerke D bel Produkt Universald bel UX Universald bel UX Schraube Typ UX 6 x 50 mm UE Bog 6 Druckfestigkeit 11 7N mm Dune 11 2 Kabelauswahl 1 DC Kabel Das DC Kabel muss den folgenden Spezifikationen entsprechen Das Kabel muss entsprechend der von den Solarzellen gelieferten Spannung und Strom ausgew hlt werden JPV PNSO4ATL GER PV PNSO6ATL GER Max 700 V DC Brunn Max 18A DC Summe aller Strings DC Kabel Konfiguration Leiterquerschnitt 2 5 10mm Au endurchmesser 4 5 10mm 27 2 AC Kabel Das AC Kabel muss den folgenden
23. meter Check Sheet No Item 34 5 Required Components Equipment and Tools Electrical System Connection Diagram for two string system FTT enna PV inverter 4 7 PV module 2 AC cable TEF Sek AC disconnector 777 DC disconnector B B B I ID O s For safety installation and maintenance work always provide a DC disconnector s in your electrical system D DC cable Banh lead Parts to be procured Crimping terminal o 5 for terminal Crimping terminal o 4 for earth lead KHT FG AC discomector I Select appropriate screws for wall di material See p 27 for details Equipment and tools for electric work hillips screwdriver rimping tool as specified by the manufacturer Output measuring instrument for ranges higher than 700 VDC Earth Tester Prepare any required items other than the above 35 6 Requirements Before beginning installation of the PV inverter PV PNSO4ATL GER PV PNSO6ATL GER make sure that the following requirements are met 6 1 Installation Location Selecting and preparing installation location When installing the PV inverter follow the requirements below to achieve optimum performance of and to ensure safe use of the PV inverter install the PV inverter indoors It is PROHIBITED to install the PV inverter in places unable to be separated from outdoor environment such as gara
24. n PV inverters Longitudinal distance between PV inverters Unit mm 38 6 2 Requirements for Connection to PV Module Up to three strings are connectable to the PV inverter Make sure that the sizes and requirements for the PV modules you are connecting meet the DC input requirements for the PV inverter Active modules must satisfy the following DC input requirements DC Input Requirements Max DC voltage per string 700 VDC Min DC voltage per string 150 VDC Max input current sum of each string 18 0A DC A DC disconnector must always be inserted between the PV inverter and connected PV modules to avoid electric shock during installation of or maintenance work on the PV inverter 6 3 Requirements for Connection to Grid For connection of the PV inverter to the grid the relevant technical regula tions as well as specific requirements defined by the local utility company must also be complied with Make sure that the grid to which you are connecting the PV inverter meets the requirements as follows Connection requirements Voltage range 184 264 V Frequency range 49 8 50 2 Hz Qn order to minimize power losses cables with cross sectional area appro priate to their lengths must be used An AC disconnector must always be inserted between the grid and the PV inverter 39 7 Installing PV Inverter PV PNSO4ATL GER PV PNSO6ATL GER The following illustrates the installation of the PV inverter
25. olarstrom Wechselrichter Verbindung an den muss repariert werden Klemmen f hrte Wenden Sie sich an Ihren zum Durchbrennen H ndler der Sicherung Die Spannung Wenn die Solarzellen morgens oder zum nachts kein Licht empfangen wer Wechselrichter ist den keine Informationen angezeigt zu niedrig oder Dies ist normal Vergewissern Sie der die DC sich dass die DC Kabel korrekt an Trennschalter ist die Klemmen und ausgeschaltet angeschlossen sind Vergewissern Sie sich dass der die Trennschalter eingeschaltet ist Lassen sich durch diese Vorschl ge die Probleme nicht beseitigen oder wird ein Fehler angezeigt der hier nicht erw hnt ist wenden Sie sich an Ihren H ndler 24 10 Vorsichtsma nahmen bei der Wartung IN WARNUNG Die Solarzellen versorgen Ihren Solarstrom Wechselrichter mit einer gef hrlich hohen Gleichspannung Die Frontplatte des Solarstrom Wechselrichters darf nur von einem qualifizierten Techniker ge ffnet werden lt ffnen der Frontplatte gt Schalten Sie den AC Trennschalter AUS Schalten Sie den DC Trennschalter AUS Warten Sie 30 Minuten Hierdurch k nnen sich die Kondensatoren im Wechselrichter entladen D Entfernen Sie die beiden Schrauben mit denen die Frontplatte unten befestigt ist 2 Nehmen Sie die Frontplatte ab L sen Sie auch das Massekabel von der Frontplatte Nehmen Sie das isolierte Teil des Massekabels und ziehen es in die abgeb
26. omagnetischen Vertr glichkeit und den Niederspannungs Richtlinien Au erdem werden die Vorschriften der DIN VDE 0126 1 1 abgedeckt 2 Sicherheitshinweise Der Wechselrichter darf nur von ausgebildeten Technikern installiert werden Die Installationsarbeiten d rfen nur durchgef hrt werden wenn das Ger t auf der Gleich und Wechselstromseite vom Netz getrennt wurde Die folgenden Symbole zeigen den Grad und die Art der Gef hrdung wenn die Sicherheitshinweise nicht beachtet werden Warnt vor Lebensgefahr oder schweren Verletzungen wenn die Arbeiten am Wechselrichter falsch durchgef hrt werden Ber hren Sie keine Teile des Systems mit nassen H nden Sonst kann es zu einem Stromschlag kommen Die Kabel der Solarzellen f hren Hochspannung Verboten Installieren Sie den Wechselrichter nicht drau en Ein Brand oder ein Stromschlag k nnen die Folge sein Bauen Sie den Wechselrichter nicht auseinander oder modifizieren ihn und installieren Sie ihn nur so wie im Installationshandbuch und in den Schaltpl nen angegeben Nicht Das Ger t kann herunterfallen und ein Stromschlag oder ein Brand auseinanderbauen oder modifizieren Kann die Folge sein Trennen Sie das Ger t immer vom Gleich und Wechselstromnetz wenn Sie Wartungsarbeiten durchf hren Warten Sie 30 Minuten bis sich die integrierten Kondensatoren entladen haben ehe Sie die Frontplatte ffnen Sonst kann es zu einem Stromschlag kommen Schlie
27. q 14 20 8 1 Solarzellenanschluss DC Eingang 14 17 8 2 Anschluss 18 19 8 3 Nach dem Anschluss der Kabel 20 xu Sege ee E e ee b NOE RUE e a 21 24 9 1 Tests vor Inbetriebnahme 21 9 2 Probelauf Starten 21 22 9 3 Problembeseiligung s a e mese eremitt tips 23 24 10 Vorsichtsma nahmen bei der Wartung 25 26 11 Anhang e hr rh hh pp nn nn 27 28 11 1 Schraubenauswahl 27 11 2 RKabelauisw anhl 4464444 4 5 S X eu ende E ex 27 28 11 3 Kabel sen und 28 1 Einf hrung V _ 2 ea S S N Der Solarstrom Wechselrichter PV PNSO4ATL GER PV PNSO6ATL GER wandelt Gleichstrom erzeugt durch Solarzellen in Wechselstrom um und speist diesen in ein Stromnetz ein In diesem Installationshandbuch werden die Montage des Wechselrichters der Anschluss an die Solarzellen und an das Stromnetz sowie der Testlauf des Wechselrichters beschrieben Die Bedienung des Solarstrom Wechselrichters PV PNSO4ATL GER PV PNSO6ATL GER wird in dem entsprechenden Kapitel SOLARSTROM WECHSELRICHTER PV PNSO4ATL GER PV PNSO6ATL GER Bedienungsanleitung beschrieben Der PV Inverter PV PNSO4ATL GER PV PNSO6ATL GER entspricht den Vorschriften zur elektr
28. r to the AC output 1 Check the grid for the correct voltage Make sure the voltage is of 184 to 264V 2 Make sure that AC and DC disconnectors are off Take care not to allow any power to flow unexpectedly during operation Perform the following procedure to connect the AC cable to the PV inverter Run the AC cable through the AC cable gland of larger diameter on the bottom of the PV inverter then firmly attach a crimping terminal for 5 Assuredly install the accessory Core lead crimping terminal 4 the earth PE conductor Avoid confusing AC and DC cables AC cable gland of larger diameter Run the AC cables and earth PE conductor through the protective tube 20 and connect cables L and N to terminals L and N of the AC output respectively Protective j QG Avoid confusing phase L with phase N i Tightening torque 2 6 3 4 N m 46 Connect the earth PE conductor to the hookup on the right side of the AC output terminal of the PV inverter Tightening torque 0 9 1 1 N m Bind the protective tube with the accessory cable tie with the AC cables held therein Fasten the AC cable gland Tightening torque 5 N m Turn on the AC disconnector and then check for the correct voltage across the terminals L N on the AC side 7 Turn off the AC disconnector 47 8 3 Actions After Connection Fasten the AC cable gland and DC and cable glands so tha
29. stallation Manual illustrates the installation procedure for the PV inverter the connection procedure for the PV module and grid and test running of the PV inverter Operation of the PV inverter PV PNSO4ATL GER PV PNSO6ATL GER is illustrated in the section PHOTOVOLTAIC INVERTER PV PNSO4ATL GER PV PNSO6ATL GER Operation Manual The PV inverter PV PNSO4ATL GER PV PNSO6ATL GER complies with the regulations stipulated in EMC and Low Voltage Directives It also meets the provisions defined in DIN VDE 0126 1 1 31 2 Safety Precautions Only qualified technicians may work on the PV inverter The installer may work on the PV inverter only when the power sources are disconnected at the alternating and direct current sides The following symbols denote the type and degree of danger that may result from incorrect use Alerts you to potential death or WARNING serious injury anticipated if worked on the PV inverter in a wrong manner Do not touch any part of the system with wet hands or body Electric shock may result High voltages are present among the PV module array cables Prohibited po not install the PV inverter outdoors Fire or electric shock may result Never install disassemble or modify the PV inverter in ways other than those illustrated in the installation manual Falling electric shock or fire may result Do not disassemble or modify Always disconnect the power sources at the alternating and dire
30. t the openings are tightly closed D Hook to securely mount the front panel on the PV inverter Connect the earth lead under the panel to Earth the earth terminal terminal Front panel Close the panel avoiding jamming 2 Fasten the two screws on the bot tom of the panel 48 9 Test Run The following illustrates the test run of the PV inverter 9 1 Check Before Turning On The AC cable has been correctly connected of the DC cables extending from the strings have been connected Also any and all unused cable glands are closed with protective caps on the bottom of the PV inverter The front panel is securely attached to the PV inverter 9 2 Test Run Procedure Liquid crystal display LCD The following procedure should be performed after making sure that your solar cells are receiving light and no blackout is encoun tered POWER switch MODE SELECT ENTER switch switch switch 1 Turn on the DC disconnector Check Action Wait for 20 seconds Then the display shown to the left should appear on the LCD If no information is displayed see p 51 Troubleshooting 49 2 Turn on the AC disconnector Check Action 1 Press the POWER switch for 2 seconds or longer and then make sure that the information is displayed informing you that the PV inverter is starting up If the ERROR LED lights up or an error code is or has been displayed on the LCD see p 51 Troubleshootin
31. tedly during operation Follow the procedure below to connect the cables extending from the PV module DC D Remove the two screws fixing the front panel from the bottom 2 Remove the front panel Also remove the earth lead from the front panel Pick up the resin coated section of earth lead pull it to the direction indicated in the illustration Check the cable diameter of a DC cable Cable diameter check sheet using the accessory cable diameter check sheet Insert the DC cables into the hole of the cable diameter check sheet This determines whether its diam eter is smaller or larger than 6mm Different connection method for different cable diameter See p 44 6 DC Cable Run the PV module DC input cable extending from the DC disconnector through the DC cable gland of smaller DC terminal terminal ee the lower section of the X To run two or more cables first loosen the cable gland and then remove the protective cap DC cable gland DC Cable DC cable Black gland of smaller diameter DC Cable DC cable Silver gray Protective cap gland Securely attach crimping terminals Core lead 5 suited to the cable diameter to the OF DC cables respectively See p 55 Appendix approx 1 mm Press fit mark 43 For DC cables gt 6mm 1 Remove the cord clip DC terminal DC terminal 2 Run the DC cable through the pro tective tube
32. ubungen unten am Wechselrichter mit Schutzkappen verschlossen Die Frontplatte des Wechselrichters wurde sicher befestigt 9 2 Probelauf starten LCD Anzeige EA MITSUBISHI ELECTRIC Wenn Sie sichergestellt haben dass die Solarzellen konstant Licht empfangen gehen Sie wie folgt vor POWER MODE SELECT ENTER Schalter Schalter Schalter Schalter 1 Schalten Sie den DC Trennschalter EIN Pr fen Aktion Warten Sie 20 Sekunden Danach sollte die links dargestellt Anzeige auf der LCD erscheinen Werden keine Informationen angezeigt siehe Problembeseitigung auf Seite 23 21 2 Schalten Sie den AC Trennschalter EIN Pr fen Aktion 1 Dr cken Sie den EIN AUS Schalter min destens 2 Sekunden und pr fen Sie ob angezeigt wird dass der Wechselrichter gestartet wird Leuchtet die Fehler LED oder wird auf der LCD ein Fehlercode angezeigt finden Sie Informationen unter Problembeseitigung auf Seite 23 2 Warten Sie etwa 5 Minuten bis der BETRIEB Wechselrichter aktiviert ist Pr fen Sie ob mEH die LCD anzeigt welcher Strom erzeugt wird 3 Beenden Sie den Testlauf Pr fen Aktion 1 Dr cken Sie den EIN AUS Schalter min destens 2 Sekunden und pr fen Sie ob links auf der LCD angezeigt wird 2 Schalten Sie den AC und den DC Trennschalter AUS 22 9 3 Problembeseitigung Der Solarstrom Wechselrichter ist mit einem Selbstdiagnosesystem ausges tattet und Fehler werden
33. umidity is significantly high such as lavatory or bathroom Places where excessive steam oil vapor smoke dust or corrosive sub stance is present Places where it is exposed to oily smoke such as a kitchen Places where explosive or flammable gases are present Places installations are exposed to vibration or shock Places in the vicinity of flammable materials Places with unusual conditions other than those indicated above such as seafaring vessels or motor vehicles Places where damage from salt air could occur Avoid installing the PV inverter in the following places Otherwise the PV inverter might cause appliances to generate noises Places where noises or electric noises are under strict control Places in the vicinity of television or radio antennas or cables 3 Precautions for installing more than one PV inverter Install the PV inverters in a transverse direction with space between them as follow Since overall heat divergence is larger than that when one PV inverter is installed the gap between the installed PV inverters must be fully kept The PV inverter generates heat as it generates electric power while dis charging the heated air from the ventilation or exhaust opening on its left side If PV inverter B is installed immediately to the right of PV inverter hot air released from B could affect A resulting in lower cooling perform ance Wrong Lateral distance betwee
34. wo screws fixing the front panel from the bottom 2 Remove the front panel 3 Also remove the earth lead from the front panel GO Pick up the resin coated section of earth lead pull it to the direction indi cated in the illustration 53 lt Closing the front panel gt Make sure that AC and DC disconnectors are off D Hook to securely mount the front panel on the PV inverter Connect the earth lead under the panel to the Earth earth terminal terminal Front panel Close the panel avoiding jamming 2 Fasten the two screws on the bot tom of the panel 54 11 Appendix 11 1 Selecting Screws Each screw must bear at least 1176 N of load when mounting the PV invert er on the wall The locations and the type of the screw should be properly selected Choices include the following 1 For walls made of wood 50mm Drill hole Panel thickness Sorew 2 For walls made of concrete Screw 55mm 95mm an fischerwerke Plug Product Universal plug UX SEN Type UX6x50mm 022220 Dihde ooo Block compressive strength 11 7N mm Plug Block thickness 11 2 Selecting Cables 1 DC cable DC cables should meet the following specifications Cables suited to the extent of volt age and current generated on the PV modules you are connecting should be selected JPV PNSO4ATL GER PV PNSO6ATL GER Max 700 VDC Max 18A DC sum of each string Configuration DC cable