Home
        Benutzerhandbuch KÜHLVITRINEN User manual COLD
         Contents
1.                                                                                                                                                                                                                                                                                                                                                                                           E Schaltschema  K  hlvitrine HCO   KR     steckerfertig mit Nachlaufrelais  SUB D 9 pol  pas Nachtrollo   optional        Ah  o T      A     K  hlstellenregler E      4 7      ST501 KU3    E nd pco irc 2       230V  230V  230V  230V  i  l 0 24V          DO    l    i O O O        L3 Pf            a   wi          Legende    2H3H   PE N HPE NHPE N HPE    KUHL VITRINE      M1   Kompressor H PA      M2   L  fter Verfl  ssigereinheit i   p   des  M3   L  fter Verdampfersatz   E AGG AGG  1  KUHLAGGREGAT  BR ABL 4 BL   GR   e 1  S1   L  fter Steuerung    2  i   aaa l   3   Raumf  hler K  hlung   Wy     Cfo T    i i bags 1     gt    Verdampferf  hler i ELER TROCHE   a Kk ENG n    M3 NETZ AAN  Q ABTAU a n     amp    Beleuchtung K  hlung 230V 50Hz HEIZUNG        4 ea i MP as M2    AM    Heizung   RAHMEN   LICHT SW  i HEIZUNG  3   K9   Nachlaufrelais   a A B P B  i entia el BR S  i  Brillant K  hlregal  2 Aaa a    5  S K3 og   1    ODER  K9  18 Bi        CS3 1B   e   E1Z1R10      5  Lle JN  jarj jaz    z SW BL    C D C D  L1  N e bd  gt   WE TNNT RN eee                                                       E  E Schal
2.                                                                                                                                                                                                                                                                                          NS m x  optional erh  ltlichen Langs  und Querstege      Quersteg     1 6  325mm    FN    A Da  ij Es k  nnen GN Schalen mit maximaler Tiefe von 150 mm verwen    N 1 aes     Uu       det werden  Die Kombination von GN Schalen und Einlegeb  den  L  ngssteg Langssteg bietet uneingeschr  nkte Kombinationsm  glichkeiten in der  nn dar je    Warenprasentation                                                                                                                                                                                                                                                                                                                                                              Die Modelle BAK  BAK L und BAK KSL werden mit flachen  Boden ohne Hohenverstellung ausgeliefert     Die Abmessungen dieser Vitrinen ist f  r Backnorm Bleche mit  600 x 400 mm angepasst und daher fur die Prasentation von  B  ckerei  und Konditoreiprodukten bestens geeignet        Eine einwandfreie Funktionsweise kann nur garantiert werden  wenn die Zu  und R  ckluft  ffnungen  frei gehalten werden und der Kaltluftschleier nicht beeintr  chtigt wird        12 Technische   nderungen vorbehalten G  ltig ab Oktob
3.                                                                                                User manual  COLD DISPLAY CASES    self contained or remote refrigerated      n    IL   EL   KE       Cold display cases    Guidance and help for this user manual    This manual is valid for all refrigerated display cases as well as the energy optimised version GREEN     regardless of the various possibilities of glass styles and heights  assisted  or self serve displays  drop in  slide in or  free standing style  interiour for Gastronorm or Euronorm size     Below pictured possibilities are showing most of the available versions  but due customised solutions of the refri   gerated display cases it s not possible to show all possible options in this manual     40       Flexibility      C  E N VARIOUS VERSIONS FOR YOUR REQUIREMENTS       THE DESIGN  samples shown on closed displays        curved square slanting PRO curved PRO curved  not for insulated glass    THE POSSIBILITIES ON CUSTOMER SIDE  Z   a 3                   s         gt        closed open flip up doors sliding doors       THE HEIGHTS  samples shown on closed displays                      flat internal well optionally available  195 mm       Drop in Slide in Free standing Counter top PRO    41    Cold display cases    Operating and installation instruction    Copyright    October 2014  AKE Ausseer Kalte  und Edelstahitechnik GmbH  All rights reserved     No part of this publication may be reproduced  stored In a retrieva
4.                                                                 Nachtrollo   optional      Im                                                  K  hlstellenregler TNR TS UE     E         ST501 KU3    EC Ec EN A   Bee  oa    0 24 V 230V  230V  230V  230V       ar A  DO           N   vag TOW Ar AGG FEL      n   MB    i   GO         av pl       7   2    3L    Schl  sselschalter 2    egende            KUHL VITRINE      M1   Kompressor Zi yn    M2   L  fter Verfl  ssigereinheit    M3   L  fter Verdampfersatz tg     BR ABL 4    S1   L  fter Steuerung he nee tie  Wb   Raumf  hler K  hlung   NM er OH      ELEKTRISCHE M DE T    Verdampferf  hler i q y        i M3 NETZ ANN  amp  aan I E M1     amp    Beleuchtung K  hlung 230V 50Hz a     Drm     AM   Heizung   RAHMEN     igHt cS scene M     HEIZUNG Xa UD aaa RE      entf  llt bei KR     Brillant K  hlregal   LI o      N e e    Pe ge ue e cei uL I ie dtu EEEN E A  34 Technische Anderungen vorbehalten G  ltig ab Oktober 2014    Technische Information                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
5.       Benutzerhandbuch  KUHLVITRINEN    steckerfertig oder externer Kalteanschluss    User manual  COLD DISPLAYS    self contained or remote refrigerated    F    ILDE AL   K E       K  hlvitrinen    Hinweis zu diesem Benutzerhandbuch    Dieses vorliegende Benutzerhandbuch ist g  ltig f  r alle Verkaufsvitrinen und die energieoptimierten Isolierglasvitri   nen  unabhangig der verschiedenen m  glichen Ausf  hrungen betreffend Art und Hohe des Glasaufbaus  Verkaufs   oder Selbstbedienungsvitrine  Einbau   Auftisch  oder Standvitrine  Gastronorm  oder Backnorm Abmessungen     Die hier abgebildeten M  glichkeiten zeigen den GroBteil der Ausf  hrungen  bedingt durch Sonderbau sind noch  viele andere Ausf  hrungen der Verkaufsk  hl  und Isolierglasvitrinen m  glich     Flexibilitat         C  E N AUSF  HRUNGSM  GLICHKEITEN    DAS DESIGN  Ger  tefotos als Beispiel f  r geschlossene Vitrinen           rund       eckig    DIE M  GLICHKEITEN DER KUNDENSEITE    n   al    gt  a             e      n         L E          2         i r      E  geschlossen offen Entnahmeklappen Schiebet  ren    DIE HOHEN  Ger  tefotos als Beispiel f  r geschlossene Vitrinen     530 mm    schrag    PRO eckig  nicht bei Isolierglasvitrinen    PRO rund             370 mm                      optional flache Innenwannen mit 195 mm moglich    MONTAGEVARIANTEN  Ger  tefotos als Beispiel f  r geschlossene Vitrinen     yery       Drop in       Slide in    Stand    Auftisch PRO    K  hlvitrinen    Benutzerhandbuch und
6.       gt   DJONS    r    ml    Um eine einfache Bedienung zu erm  glichen wurden die wichtigsten  Parameter in eine eigene User Ebene gelegt     L S USER Ebene    Mit der Auswahl des Codewortes L 5r und der Eingabe des Passwortes  gelangt man direkt in eine Liste mit vordefinierten Parametern     Dies sind die Parameter L5  d i de  d3  FH  FH H ld  He lundi      G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 31    Technische Informationen    a    vE    K  hlvitrinen    Parameter der USER Ebene    c5 Hysterese Regelkreis 1  In diesem Parameter wird die Regelhysterese angegeben  Eine kleine Hysterese erlaubt eine genauere Regelung   f  hrt aber auch zu h  ufigerem Schalten des Relais     d    Abtauintervall   Das Abtauintervall legt die Zeit fest  nach der jeweils eine Abtauung eingeleitet wird  Mit Beginn der Abtauung  wird das Abtauintervall neu gestartet  Eine Abtauung kann auch durch Dr  cken der Taste AUF   Handabtauung    f  r mindestens 3 Sekunden oder eine parametrierte Taste eingeleitet werden    ber die interne Wochenschaltuhr  kann die Abtauung auch in Echtzeit gestartet werden  Der Regler beginnt nach dem Einschalten sofort mit dem  K  hlen und startet die erste Abtauung nach Ablauf des in d   eingestellten Intervalls  Wird  d i 0  eingestellt  so  erfolgt keine automatische Abtauung     dc Art der Abtauung   Mit diesem Parameter wird angegeben  ob eine Abtauung erfolgen soll und wenn ja  wie die Abtauung erfolgen  soll  M  glich ist ein einfaches Abschal
7.    15   Fortw  hrende Entwicklung    Die Firma AKE behalt sich das Recht vor  Spezifikationen und Konstruktion  als Bestandteil einer fortwahrenden  Produktverbesserung jederzeit zu ver  ndern     G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 7    Benutzerhandbuch    Teil    K  hlvitrinen    16  G  ltigkeit    Diese Betriebsanleitung gilt f  r die folgenden Modelle  steckerfertig oder zentralgek  hlt      Gastro und BAK    G     kundenseitig Panoramascheibe oder Klappen fur Selbst   entnahme    K  hlvitrine Gastro    O     Kundenseitig offen    K  hlvitrine Gastro    HCG     kundenseitig Panoramascheibe oder Klappen f  r Selbst   entnahme    K  hlvitrine Gastro    HCO     kundenseitia offen    Auftischvitrine Gastro    A    bzw  Green    A     kundenseitig Panoramascheibe bzw  Panoramascheibe  isoliert    K  hlvitrine BAK   L    und    KSL     kundenseitig Panoramascheibe  Stand  oder Einbauvitrine  mit Ladenauszug bedienseitig     KSL    mit Unterbauk  hlung    Kuhlvitrine Gastro  KSV     kundenseitig Panoramascheibe  mit Unterbauk  hlung zur  Bevorratung    K  hlvitrine Green    G    und Green    O     kundenseitig Panoramascheibe isoliert oder offen   Seitenscheiben isoliert  Einbauvitrine       K  hlvitrine Green    KSL    und Green    L    mit Auszug  kundenseitig Panorama  und Seitescheiben isoliert  mit  Ladenauszug  KSL mit Unterbauk  hlung zur Bevorratung     BRILLANT KR  kundenseitig offen  Seitenscheiben isoliert       K  hlvitrine Green    KSV     kund
8.    8U  H    Sensor Evaporator     amp    Lightning    POWER SUPPLY  X   Magnetic valve M3 230V 50Hz ANN 8 X  AM    Frame Heating FRAME external  by customer  LIGHTIN  HEATER j         Wiring diagram     L1    PE    12             rn oO                000 8                                           SUB D 9 pole       ee a lm ccc cA D Cm            MEZEA                                                                                                                                                                                                                                                                                                    Display case HCO and KR     self contained without time delay relay    Night shade   option      p                                               4                                     x       ITAN      Cooling control unit o o   NEM Zi    KL K3 K2 K1       I      S     ST501 KU3    1612 24   1612 2 A 162A 30 6 a    BN re NR NE        D      EN 230V  230V  230V  230V       o o     i    Q Q          7 r I F F   ids ABK ABN NYE    1   21   513                          a    2 PE NHpeH HI N Het NHPE   MEME  Legend   eke   uo EH Dil nn E     COOLING UNIT     8    M1   Compressor    i i    M2   Blower Condensor   8N i BN  2  GNYE   GNYE  M3   Blower Evaporator en Mu 4 gu   eu   COOLING UNIT    j   Compressor Condenser   S1   Blower Speedcontrol   ANN   wen   F   Sensor Room COLD     ELECTRICAL     a OM    H   Sensor Evaporator M3 POWER supply     ANN
9.    Legend   COOLING UNIT       M1   Compressor  M2   Blower Condensor  M3   Blower Evaporator  S1   Blower Speedcontrol    Sensor Room COLD   amp    Sensor Evaporator   amp    Lightning  AM       Frame Heating                L1 e    Schematic circuit diagram    Display cases     self contained without time delay relay  Gastro  Gastro HCG  BAK and Green models       Ps an       Cooling control unit  ST501 KU3       O 24V             16  2       K1  30 6  A  230V                                                          POWER SUPPLY  230V 50Hz                                           FRAME  HEATER          COOLING UNIT     Compressor Condenser           r  i       2  bit  BR     El       jd  J             DE ge                                            ee    Wiring diagram                          OOO                C  J90 OO               pL eee e  ec             Legend                    Display cases     self contained with time delay relay  Gastro  Gastro HCG  BAK and Green models                                                                                                                                                                   COOLING UNIT       M1   Compressor   M2   Blower Condensor  M3   Blower Evaporator  S1   Blower Speedcontrol     amp    Sensor Room COLD              Sensor Evaporator          Lightning  AWW    Frame Heating                K9   Time delay relay                                                                                     L_    5 5
10.   sentation zu garantieren  muss die  gesamte Technik regelm    ig gepr  ft und gewartet werden     Service und Wartung  Problembehandlung    Vorgeschriebene Anpassungen  Service und Kontrollarbeiten m  ssen rechtzeitig vom Manager oder wenn  notwendig von einem autorisierten Servicetechniker vollendet werden     Das Bedienungspersonal muss vor Beginn der Wartungs  oder Servicearbeiten informiert werden     Das Ger  t muss vom Hauptschalter getrennt werden  bis die Wartung  Kontrolle und Reparatur abgeschlossen  ist  Ein unbeabsichtigtes Einschalten muss vermieden werden     Pr  fen Sie alle Schrauben  ob sie festgezogen sind     Technische Informationen    Nach Abschluss der Wartung   berpr  fen Sie alle Sicherheitsbauteile auf einwandfreie Funktion   Teil   Viele Ma  nahmen k  nnen vom Betreiber selbst ergriffen werden  B   Grundreinigung des gesamten Innenraumes   Funktionspr  fung der Ventilatoren   Pr  fung der Warentemperatur   Pr  fung und Reinigung der Abflussleitung bzw  Tauwasserverdunstung   Reinigung des Kondensators an der K  hlmaschine  nur f  r steckerfertige Ger  te     Der Kondensator der K  hlmaschine ist stets sauber zu halten  Verschmutzte Lamellen f  hren zur    berhitzung  im schlimmsten Fall zur Zerst  rung des Aggregats        Folgende Arbeiten sind von einem Servicetechniker durchzuf  hren     Pr  fung der Thermostateinstellung  Pr  fung der K  ltemittelmenge  Sicherheitspr  fung der Anlage    3 2  Bezug von Ersatzteilen    Bitte wenden Sie sich bei d
11.  5 5 5 5 5 5 5 5                                                                               Cooling control unit Q    K4 i  ST501 KU3    ENAN ME  0 2LV 230V     U      Vv Joa        amp  O    E       COOLING UNIT  i BN  Compressor Condenser      1   pe 0 1  f  n ou    Dee    eeu CMM     c    u  M3 POWER SUPPLY ANN AMNES RE    230V 50Hz  i FRAME 2 A B    HEATER    E  ol EE RN  i o  4     018  Bfi    L3       EIZIRIO    i           e  Ken arts ta       BU    D c D                      PE Gee                         P en o EBERT ED EET    Valid from October 2014    Technical changes reserved       Technical inforamtion    Cold display cases    Wiring diagram     L1    PE    Display cases   remote refrigerated  Gastro  Gastro HCG  BAK and Green models                                                                                                                                                                                                                                                                                                                                     SUB D 9 pole  Oo IDEOke b  L    M       Lets   0          Cooling control unit o o o      K4 K3 K2 K1    A     ST501 KU3    SEE IAN 16 2 214   1612214   N      230V  230V  230V  230V        OO doge      T   T       s  CD  ED   Ke  cs G    Legend  EUS STUNT LN eer Hee iHe iHe    COOLING UNIT    M3   Blower Evaporator AU AU    S1   Blower Speedcontrol   BN BN  oer  g  b wt GNYE  4   Sensor Room COLD 6N ABU    d BU
12.  Auch beim Einsatz von GN Schalen ist darauf  zu achten  dass diese nicht   berf  llt werden  speziell im Bereich der Ausblas  ffnungen des Verdampfers     Die Innenraumtemperatur des Ger  tes reagiert wesentlich sensibler auf Temperatur  nderungen als die gelagerte  Ware  Diese reagiert wesentlich tr  ger  sodass bei der Einlagerung von nicht ausreichend vorgek  hlten Produkten das    Thermometer zwar die gew  nschte Temperatur anzeigt  jedoch die gelagerte Ware diese noch nicht erreicht hat     Je nach Art der gek  hlten Getr  nke ist darauf zu achten  dass die Temperatur des Innenraumes nicht zu kalt ein   gestellt ist  da es sonst zum Gefrieren der Fl  ssigkeit und somit zum Bersten der Getr  nkeflaschen kommen kann     14 Technische   nderungen vorbehalten G  ltig ab Oktober 2014        Benutzerhandbuch Okre    9  Reinigung und Pflege    Nachfolgend m  chten wir Ihnen einige Ratschl  ge bez  glich Wartung  Pflege  Problembehandlung und Service  Ihres K  hlger  tes geben  Das Ger  t ist t  glich entsprechend den Hygieneverordnungen innen und au  en zu rei   nigen  Nur so kann eine optimale Warenpr  sentation garantiert werden     ACHTUNG   Vor allen Reinigungs  und Servicearbeiten ist die Stromzufuhr zu unterbrechen  Dazu die K  hlvitrine  ausstecken oder zweipolig vom Netz trennen        Da das Ger  t w  hrend der Reinigung ausgeschaltet sein muss  ist es am sinnvollsten  das K  hlm  bel am Ende des  Arbeitstages zu reinigen  Die K  hlvitrine kann   ber Nacht bzw  au  er
13.  Beachtung zu schenken  k  nnte zu St  rungen am Gerat oder der  Umgebung f  hren        14  Allgemeine Sicherheitshinweise    Technische Veranderungen an der K  hlvitrine d  rfen nur durch Fachleute vorgenommen werden   Dies gilt im Besonderen f  r Arbeiten an Kaltetechnik  Elektroinstallation und Mechanik   Jede Anderung muss durch den Hersteller autorisiert werden        Mit Warnhinweisen versehene Abdeckungen d  rfen nur durch Fachleute geoffnet werden    Die M  bel Unter  und R  ckseite darf nicht mit einem Wasserstrahl gereinigt werden    ochutzabdeckungen und Vorrichtungen d  rfen nicht entfernt werden  da sonst Verletzungsgefahr besteht   Die Steuerung darf nur von einem Fachmann geoffnet werden     L uftstr  mungen im Bereich des K  hlger  tes durch unsachgem     installierte L  ftungen oder Zugluft m  ssen  vermieden werden  um eine einwandfreie Funktion der K  hlm  bel zu gew  hrleisten     Die Umgebungstemperatur darf 25   C und die relative Umgebungsfeuchtigkeit darf 60 96 nicht dauerhaft   ber   schreiten     Die zur Prasentation gebrachten Produkte m  ssen vorgek  hlt und mit einer Kerntemperatur von mindestens  5   C oder kalter eingebracht werden     ocharfe Gegenstande d  rfen nicht lose im K  hlm  bel aufbewahrt werden  da sonst Verletzungsgefahr besteht     Alle Glasaufbauten m  ssen mit der notwendigen Sorgfalt behandelt werden  um Verletzungen durch Glas   bruch zu vermeiden     Bauteile und Betriebsmittel d  rfen nur durch Originalteile ersetzt werden  
14.  Einbauanleitung    Copyright    Oktober 2014  AKE Ausseer Kalte  und Edelstahitechnik GmbH  Alle Rechte vorbehalten     Kein Teil dieser Publikation darf in irgendeiner Weise reproduziert  gespeichert  oder in irgendeiner Form oder mit  irgendwelchen Mitteln versendet und ver  ffentlicht werden  ohne die vorherige schriftliche Erlaubnis der Firma  AKE     Dokument  BH Verkaufsk  hl Isolierglasvitrinen dt en indd  Hevision  14A  G  ltig ab  Oktober 2014    Inhaltsverzeichnis    Teil A Benutzerhandbuch    1   Yel   1 2   1 3   1 4   1 5   1 0   Pa   3    4    o    6   DU   D 2   6 3   6 4   6 5   6 6   re   8   8 1   B   d   9 1   9 2   9 3   g i   9 3 2   9 3 3   10   11   11 1   11 2    Einleitung   Willkommen   Garantie und Haftung   Symbole und Kennzeichen   Allgemeine Sicherheitshinweise  Fortw  hrende Entwicklung   G  ltigkeit   Verwendungszweck  Bestimmungsgem    e Verwendung  Nicht bestimmungsgem    e Verwendung  Sicherheitsrichtlinien   Allgemeine Bedienungshinweise   Erste Inbetriebnahme   K  hlm  bel einschalten  Temperatureinstellung  Abtau Automatik   Manuelles Abtauen   Beleuchtung   Best  ckung der Vitrine mit Ware  Funktionsbeschreibung der K  hlvitrinen  Temperatureinstellung   K  hlunterbau  Best  ckung   K  hlunterbau   Heinigung und Pflege   Generelle Empfehlung  Reinigungsmittel   Spezielle Anmerkung fur die Reinigung  Reinigung des Innenraumes und des Verdampfers  Reinigung der Glaser   Reinigung des Nachtrollos   St  rungen und Ursachen   Gefahren   Elek
15.  L  fter Verdampfersatz    S1   L  fter Steuerung ee een      F   Raumf  hler K  hlung  P cee l  IP   Verdampferf  hler qur p  T  x P4        CN ae M1   amp    Beleuchtung K  hlung s  cbe  amp      Wy   Rahmenheizung   RAHMEN LICHT a ee S    HEIZUNG  L1    N e       M       Q                                                                                   A   AA A A                      HR i ee      E Schaltschema  K  hlvitrine   steckerfertig mit Nachlaufrelais  Gastro  Gastro HCG  BAK und Green Modelle  SUB D 9 pole  l         gt  EB   oo      K  hlstellenregler  ES   UNS             ST501 KU3    za EZAN 1612 2 4  N       A D      0 2LV 230V  230V  230V  230V           I  TCI    Io CD     Ka              Loreng    I2H3 H  HsHsF MNHbE N HPE N HPE nHPeEH    EH N Hec    KUHL VITRINE        M1   Kompressor Mt Vit        M2   L  fter Verfl  ssigereinheit   i Hr   fz K  HLAGGREGAT  M3   L  fter Verdampfersatz  g  i  GG GG 1 Bene  1      R m   cd   BL   GR   Ow aa l   S1   L  fter Steuerung i      2  i   qu m mq    F   Raumf  hler K  hlung         LM M1    HP   Verdampferf  hler    a M3 us ANN  amp  ut UT          G9   Beleuchtung K  hlung 230V 50Hz e ee    ANY   Rahmenheizung   RAHMEN LICHT x B la 4  K9   Nachlaufrelais   HEIZUNG P A Ls  a Serene INN    mise      i  JODER   2  18  BT    E   CS3 1B       E1Z1R10      5  ife fl N     TA1 115 TA2    z SW BL      C D C D  L1    N e e    MEE n L i ae a a ee eS    Gultig ab Oktober 2014    Technische Anderungen vorbehalten    33    Te
16.  Passwort gesch  tzt                  PA          0 0         us    e 9   usu                                   n Passwort  123    Einstellung des Hauptsollwertes       g     mi y  7  un 5  m    n Passwort            Durch Dr  cken der SET Taste wird der Sollwert in die Anzeige gebracht   Soll der Sollwert ver  ndert werden  ist die SET Taste f  r die Dauer der  Einstellung gedr  ckt zu halten und mit den Tasten AUF oder AB der  gew  nschte Wert einzustellen  Die Taste AUF oder AB ist nach dem  Einstellen stets zuerst loszulassen  dann erst die SET Taste  Dies gilt beim  Sollwert und allen anderen Parametern     4x         S      D    eR         uj    Man beachte  dass der Sollwert nur innerhalb der eingestellten Sollwert   Grenzen verandert werden kann  Wird mit den Tasten AUF oder AB eine  Anderung   ber diese Grenzen hinaus versucht  blinkt die Anzeige     DA       Olu    Ofm               Einstellung von Regelparametern der USER Ebene    nN  LO      Der Einstieg in die Parametrierung erfolgt mit dem gleichzeitigen  Dr  cken der Tasten AUF und AB  Nach zirka drei Sekunden erscheint in  der Anzeige das Codewort Har  Durch Bet  tigung der AUF bzw  AB Taste  kann zwischen dem Codewort Adr  PR  USr und HSL gewechselt werden   Alle weitere Einstellungen bzw  Wertvorgaben in der Parametrierebene  erfolgen mit der allgemeinen Methode der Wertvorstellung  das hei  t mit  dem gleichzeitigen Dr  cken der Tasten SET beziehungsweise AUF oder  AB      a   x    amp    xz   a   a TU    n
17.  Q ee ae eee  D 230V 50Hz i EO NR i    C9   Lightning   FRAME Blue   TEE  i LIGHTING DAMM AA    ANY   Heating i HEATER    not applicable  i by KR  i  Brillant multidecks                Q             un i    Technical changes reserved    Valid from October 2014       Technical information    Wiring diagram  Display case HCO and KR     self contained with time delay relay                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        SUB D 3 pole Night shade   option    oO ke O IT     gt    se      0         o i i      Cooling control unit      Kh K3 K2 Ki           ST501 KU3    Tela 2A 16208 1612 21 aA       D          230V  230V  230V  230V     o o   U           77                    ei   km   m    Legend  La eae UU RUNS Te UBI  COOLING UNIT      M1   Compressor AU      M2   Blower Condensor   BN   Au COOLING UNIT      IGNYE IGNYE  1   Compressor Condenser   M3   Blower Evaporator An MBU  amp  BU   GY i a ia sauer 1     2      Fr    S1   Blower Speedcontrol     mode      oe     VW     td X X        Sensor Room COLD   i ELECTRICAL i E         N ud M1   c    Sensor Evaporator G
18.  and disconnect it from the mains         For cleaning purposes the unit must be turned off  Therefore  the best time for cleaning is at the end of your wor   king day  The display case can be switched off during the night or outside of opening hours     l 8  g 1  General recommendations    The unit has to be cleaned daily  3  Wear acid proof gloves while cleaning the parts to prevent skin irritations   After cleaning with special cleaners you have to wash all parts with clear water and dry them so that there is no Part  cleaner residue on these parts  A    It is absolutely necessary to bear some fundamental things in mind to keep this stainless steel unit working and to  maintain its long life   Always keep the stainless steel surface clean     Make certain there is always enough fresh air on the surface   Never let the surface come into contact with rusty material       9 2  Detergents    Use the following detergents        Lukewarm soapy water  Use lukewarm soapy water for all surfaces that are in direct contact with the goods     Glass cleaner  Removes grease from glass surfaces  You can lift the glass panels for easy cleaning of the glass  and the surfaces underneath     Stainless steel cleaner  The stainless steel surfaces should be cleaned with a stainless steel cleaner only   Lamps  The lamps are to be cleaned with soft paper or cloth only     Drawers  GN pans  Easily removable without tools for separate cleaning  Use brushes with plastic or natural  bristles for clea
19.  befreien  3   Achten Sie darauf  dass die Lamellen nicht verbogen werden  E       ftungsgitter wieder anbringen  N       QU   ca  Die Zu  und Abluft  ffnungen des Kondensators d  rfen nicht verschlossen oder durch Gegenst  nde zugestellt Teil  werden  da ansonst die K  hlleistung beeintrachtigt oder im schlimmsten Fall der Kompressor zerstort wird  A    ACHTUNG   Die Lamellen des Kondensators sind sehr d  nn und scharf  Vermeiden Sie aus Verletzungsgr  nden  den dirketen Kontakt zu den Lamellen        9 3 2  Reinigung der Glaser    Die Frontscheiben k  nnen zur leichteren Reinigung nach vor geklappt werden  Bild 1   Die Deckglaser sind nach  oben bewegbar  Bild 2  und erleichtern so die Reinigung der Innenseite   ACHTUNG  Halten Sie die Gl  ser w  hrend des Reinigen fest und lassen Sie die Frontgl  ser nicht nach vorne  fallen   Frontgl  ser aus Isolierglas  Bild 3  werden durch ein Sicherungsseil in Endposition gehalten  Beim   ffnen  muss das Glas jedoch unterst  tzt werden  um das Sicherungsseil zu schonen   Bei gr    eren Vitrinen sollten zwei Personen die Glaser kippen und reinigen  Das Gewicht der Glaser sollte  nicht unterschatzt werden        9 3 3  Reinigung des Nachtrollos    Das Nachtrollo der Vitrinen  z B  bei Gastro HCOE  soll in regelmaBigen Abstanden mit einem feuchten Tuch  gereinigt werden     Technische Veranderungen an der K  hlvitrine d  rfen nur durch Fachleute vorgenommen werden   Dies gilt im Besonderen f  r Arbeiten an Kaltetechnik  Elektroinstallati
20.  in case of ambiguity by the installa   tion  during the operating or by the attendance  to coll your dealer  Often some questions can be cleared by a  simple telephone call     With the proper treatment you will enjoy this appliance for a long time  Please keep these operating and mainte   nance instructions to consult in case any maintenance and repairs are needed  With the purchase of this new ref   rigerating equipment you have decided on a product that combines the highest technical demands with practical  service comfort     12  Warranty and liabilities    Fundamentally  our    General terms of sale and delivery    are valid  These are known to the operator upon the  signing of the contract at the latest  Claims of warranty and liability for damage to persons and property are not  possible  if they result from one or several of the following causes     Improper use of the unit   Improper assembly  start up  operation  amp  maintenance of the unit     Operating the unit with defective safety devices or safety devices which have not been installed properly and  are not in working condition     Disregard of the instructions in the operating manual concerning transportation  storage and installation   Unauthorized mechanical or electrical changes to the unit    Insufficient maintenance of wear and tear parts    Unauthorized repair    Extreme environmental exposure  fire  explosions e g    Forces of nature or force majeure risk    Also excluded from the liabilities are   Bre
21.  it will be stopped     FH Fan speed in control mode  Set1  Fan speed in normal control mode and active Set1    FH Fan speed during defrosting  Set1  Fan speed during defrosting and active Set     H ic Calibration of sensor F1 actual value correction   With this parameter it is possible to correct actual value deviations caused by sensor tolerances  very long sensor  cables or structural protections  e g  ex barriers   for example  The value defined here is added to the measured  value     HZ   Actual value sensor F1   The temperature value shown here is used for control  It is calculated as follows    Actual control value     actual measured value   weighting factor     actual value correction   Actual value correction and weighting factor must be defined in the following parameters  This corrects actual  value deviations in special applications  refrigerated shelves or similar  due to unfavourable sensor location     Li Display in standby mode   In this parameter  you can define what is to be displayed in standby   L5 Pre defined parameter sets   ui Internal  active data set    With this parameter  you can set up pre defined data sets  The data sets are provided by Stork Tronic  If a new data  set is loaded  all previously set parameters will be overwritten  After that  they can be edited as required     70 Technical changes reserved Valid from October 2014    Technical information    5     Wiring diagram                             000           e            QD  DO        
22.  mit lauwarmem Seifenwasser zu reinigen  Innenraum immer  trocken wischen  Nach erfolgter Reinigung den Verdampferkasten leicht anheben  seitliche Arretierung nach  innen schwenken und Verdampferkasten absenken     Danach die Innenwanne wieder einlegen  seitliche Luftleitoleche mit den Einh  ngeleisten positionieren und  die Einlegeb  den bzw  GN Behalter wieder einsetzen    Die AuBen  und Unterseite der K  hlwanne darf nicht mit einem Wasserschlauch oder der Waschburste gerei   nigt werden  Flie  wasser ist in diesem Bereich auf jeden Fall zu vermeiden     Alle weiteren Oberflachen k  nnen mit milden Reinigungsmitteln und Wasser gereinigt werden     Alle steckerfertigen K  hlger  te ben  tigen eine regelm    ige Reinigung des Kalteaggregates  Ein verschmutzter  Kondensator ist die Hauptfehlerquelle f  r verringerte Kalteleistung    berhitzung des K  lteaggregates bis hin zur  Schadigung des Kompressors     Genauso wie die t  gliche Reinigung des K  hlm  bels ist eine monatliche Reinigung des Kondensators  bei starker    Verschmutzung w  chentlich  n  tig  um Schmutz und Staub von der Kondensatoroberfl  che zu entfernen und so  eine einwandfreie Funktionsweise zu garantieren     16 Technische   nderungen vorbehalten G  ltig ab Oktober 2014    7    IDEAL   KE        Benutzerhandbuch    Anleitung zur Reinigung des Kondensators    Entfernen Sie das L  ftungsgitter oder Kondensatorschutz        Den Kondensator der K  hlmaschine mit einem Handbesen oder S   Staubsauger vom Schmutz
23.  or flaps for self service    Kuhlvitrine Gastro   O     Customer side open    K  hlvitrine Gastro    HCG     Customer side closed  or flaps for self service    K  hlvitrine Gastro   HCO   Customer side open    Auftischvitrine Gastro    A     Green    A     Customer side closed or insulated    K  hlvitrine BAK    L    und    KSL     Customer side closed  stand alone  or drop in unit with draw   er for cakes on service side     KSL    with refrigerated base    K  hlvitrine Gastro  KSV     Customer side closed  stand alone unit with refrigerated base    K  hlvitrine    Green G     Green    O     Customer side closed and insulated  side glas panes  insulated    K  hlvitrine Green    KSL    und    Green L    mit Auszug  Customer side closed and insulated  side glas panes insula   ted  stand alone units with drawer and refrigerated base    BRILLANT KR  Customer side open  side glas panes insulated       K  hlvitrine Green    KSV     Customer side closed and insulated  side glas panes insula   ted  stand alone unit with refrigerated base       46 Technical changes reserved Valid from October 2014    7    IDEAL   KE        User manual    2  Purpose of use    These refrigerated display cases can be installed in virtually any counter and can be provided as fully self contai   ned   just plug it in and turn on   or remote  where there is a need to locate the compressor at a different location   They are suitable for the refrigeration and presentation of foodstuffs and drinks at tempera
24. 4 Technical changes reserved Valid from October 2014    7    IDEAL   KE        Technical information    2 8  Calibration of the sensor    Each installation and start up requires control and eventually a correction of the actual value correction  after 2 to 3 hours runtime     Why  Temperatur is measured before the evaporator coil  return air   this value is sometimes different to  the average temperature inside the cabinet  depending on the conditions of the location     Factory setting was done for 25   C room temperature  According to different ambient conditions there are many  influences to the installed refrigerated equipment  With this parameter H12 it is possible to correct actual value  deviations caused by sensor tolerances  very long sensor cables or surrounding conditions  of the location     Sample  Sunshine  heating sources or raised room temperature causes higher temperatures inside the  cabinet than shown on the digital display     Sample  Conditioned rooms  about 22   C  causes lower temperatures inside the cabinet than shown on the  digital display     Which temperature is inside the cabinet   Place some thermostats on the shelves and measure the actual temperature inside the cabinet  Compare the mea     sured temperature with the value shown on the digital display and adjust the Parameter H12  see programming  instruction      c  2        S  E     S  a  c   lt    D  x     Sample   Average temperature measured inside the cabinet is   7   C  the digital displa
25. 60335 2    EN61000 4 3  EN60529  EN61000 4 4  EN60598 1  EN61000 4 5  EN60598 2 1  EN61000 4 6  EN60730 1  EN61000 4 11  EN60730 2 1  EN61000 6 1  EN60730 2 9  EN61000 6 3  EN60947  EN61058 1  EN60950 1  EN61058 1 A1  EN61000 3 2  EN61347 1  EN61000 3 3  EN61347 2 3  EN61000 3 11  EN61000 4 2 oe  EN61558  l4 fp     MY Uf o      Andreas Pilz  Managing director    Technical changes reserved Valid from October 2014       WA         J  O   lt   S   lt   Q  3  a                                                                                                                                                                                                                            
26. A and presentation of the   and confusing presenta     goods    LT tion of the goods     Valid from October 2014    Technical changes reserved 49    AL   KE       User manual    Part    Cold display cases    8     It is important to leave adequate free space for the refrigerated air to circulate within the display case  Products  should be kept clear of the shaded areas  shown in the picture   see the maximum loading height  A minimum  clearance of 40 mm should be maintained below the light fittings and air plenums  The ventilation slots at the front   1  and rear  3  of the display case must never be blocked     Operating description    The presented goods are refrigerated with cold air curtain                JSL Loading height  TRO E Loading limit  nS N  s on ans This air curtain is forced by fans which suck the air via air louvers  KS      max  50 Kg at the air plenum  1  into the Evaporator  2      ee N Loading limit In this area below the base decks the air is chilled and blown up  P4   e a EE through the ventilation slots of the air plenums at the rear  3  into     o 0   the display case  The area of discharge and return air must be  L 4    1  free of goods and never be blocked   i Ta  1   sk T All these components are designed to have an even distribution      4  i       i  A i BASE DECKS iE of chilled air in the whole display case to guarantee constant  A temperature        Maximum Load  Shelves each 50 kg  base decks 150 kg in total     The Brillant GASTRO and Smarag
27. O M3 POWER SUPPLY ANN C9 oe i T EE eee   Ae   2 en 230V 50Hz 1 M2 i 42    Lightnin 6 CL JERAME se sen   0 ea  ghtning   FRAME   LIGHTING a    AW   Heating i HEATER S  i   A B  A B S  K9   Time delay relay i cu 3 BN  fel          y    er Mi  Ten       Brillant multidecks  EI EXS Xo  BT    i E   CS3 1B H   E1Z1R10    TEN  i o              S    v   Le  JN    1A1115 Pad M       BK BU I  c    C D C D 5  LI e          N e bd i    PE u N nn u                        nen l    m Part    Wiring diagram  Display case HCO and KR  remote refrigerated    SUB D 9 pole       Night shade   option                                                                                                                                                                                                                                                                                                                                                                                                                           o    He o        procos  o            Cooling control unit c o o      Kh K3 K2 K1  A     ST501 KU3    62V 16 24 16 2 2 A 3016  A       230V  230V  230V  230V         DO    o o   EN            oT I TI LT        s  CD  2   O   O       Legend    rere sr tere DER E ee UNE ABEL    COOLING UNIT    M3   Blower Evaporator    S1   Blower Speedcontrol   BN ABN  ope IGNYE GNYE      Sensor Room COLD BU i 8U       Sensor Evaporator    69   Lightning              POWER SUPPLY AM Q grace tliat    Magnetic  X   Mag
28. USJ Ebene    d    Intern  aktiver Datensatz   Mit diesem Parameter ist vorgesehen  bestimmte vordefinierte Datensatze einzustellen  Die Datensatze werden  von St  rk Tronic vorgegeben  Wird ein Datensatz neu eingespielt  werden alle vorher eingestellten Parameter    berschrieben  Sie k  nnen danach frei ver  ndert werden     32 Technische Anderungen vorbehalten Gultig ab Oktober 2014    Technische Information    by    E Schaltschema     Schaltplane    K  hlvitrine   steckerfertig ohne Nachlaufrelais  Gastro  Gastro HCG  BAK und Green Modelle    SUB D 9 pole                      000     L                                                       777mm                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     K  hlstellenregler TEA 9 ao      A   ST501 KU3    nn N E ot       A D      0 2LV 230V  230V  230V  230V     o o   U N   N      v i o M      T T ji        c   cb   o   5   ki km     Legende       KUHL VITRINE  M1   Kompressor  M2   L  fter Verfl  ssigereinheit  M3  
29. akage of glass  breakage of plastic components  cartrige seal or illuminating parts     All damages  which could be arise by wrong setting the control unit  from unqualified people   Damage or malfunctions based on a wrong assembling of the cooling unit after the cleaning of the unit     Warranty claims can only be forwarded if all instructions are strictly followed        44 Technical changes reserved Valid from October 2014         IDEAL   K E        User manual    1 3  Symbols and notes    This symbol points to important references for the proper use of the unit   Not paying attention to these references can lead to a working disruption of the unit or to the  environment     This danger symbol means a potential or direct threat to the life and health of persons and or a  possible dangerous situation    Ignoring these references may result in dire consequences for your health and or can lead to pro   perty damages     This symbol means  Hot surface  do not touch the surface      Attention  risk of burning   The top of the shelves  the glass and s s columns at the back of the unit may be hot        User manual    This symbol points to operation tips and especially useful information of optimal use   Helps you to use all functions on your unit optimally  Part       1 4  Fundamental safety notes    The connections and any technical adaptations on the refrigerated equipment are only to be carried  out by specialists  This is especially valid for any work on the cooling technolo
30. atur ein   eingestellt     Justieren Sie die Raumklimatisierung  ver   meiden Sie W  rmequellen und direkte  Sonneneinstrahlung     Die Umgebungstemperatur im  Die Waren erreichen Raum ist zu hoch    ber 25   C    die gew  nschte    Temperatur nicht  Von au  en einwirkender Luftzug    st  rt den Zirkulationskreis der  Kaltluft     Das K  hlger  t darf nicht an Pl  tzen mit starker  Zugluft aufgestellt werden     Reinigen Sie den W  rmetauscher mit einem    Der Kondensator ist verschmutzt   Pinsel oder Staubsauger     Manuelle Abtauung einleiten oder das Ger  t f  r    Der V fer i ist  i  er Verdampfer ist stark vereist einige Stunden komplett abschalten     Das K  hlaggregat oder andere  K  hlkomponenten haben eine Servicetechniker kontaktieren  St  rung     zu wenig K  ltemittel in der Anlage Servicetechniker kontaktieren    Manuelle Abtauung einleiten  Falls keine Abhilfe     ee TEE verst  ndigen Sie einen Techniker     Die Luftzirkulation in der Vitrine wird Lassen Sie genug Freiraum zur Luftzirkulation    behindert  und halten Sie die Luft  ffnungen frei   Verdampfer vereist Die T  ren werden zu lange offen   ffnen Sie die T  ren nur solange es unbedingt  gehalten  erforderlich ist     st  ndig   Es wird zu viel warme bzw  feuchte  Umgebungsluft in den K  hlraum  gesaugt     Achten Sie darauf  dass die vorgegebenen  Umgebungsverh  ltnisse eingehalten werden     Die Ventilatoren laufen nicht  Servicetechniker kontaktieren     18 Technische   nderungen vorbehalten G  ltig a
31. aum austreten  k  nnen  Die Ansaug  und Auslass  ffnungen d  rfen vom Kunden   Betreiber w  hrend des Betriebes nicht verstellt  oder verbaut werden     Ein Schutzgitter oder Jalousie im Ansaugbereich wird empfohlen um Besch  digungen an den Lamellen des  Kondensators  und die damit verbundene Verletzungsgefahr  zu vermeiden  Verwenden Sie die L  sung  die f  r  Sie am g  nstigsten ist     L  ftungsgitter von Verkleidungen m  ssen mindestens den zweifachen Querschnitt der  Kondensatorfl  che aufweisen und m  glichst gro  e   ffnungen besitzen     Be  und Entl  ftungs  ffnungen des K  lteaggregates d  rfen niemals verdeckt werden   Die K  hlleistung wird stark verringert und infolge der   berhitzung kann das K  hlaggregat zerst  rt  werden        26 Technische   nderungen vorbehalten G  ltig ab Oktober 2014    7    IDEAL   KE        Technische Information    2 8  F  hlerabgleich    Bei jeder Neuinstallation und Inbetriebnahme einer Kuhlvitrine ist ein F  hlerabgleich nach zirka 2 bis 3 Stunden  Laufzeit erforderlich     Warum  Der Temperaturfuhler der Steuerung misst die Temperatur vor dem Verdampfer  Diese Temperatur  entspricht nicht immer der durchschnittlichen Temperatur im Warenbereich der Vitrine     Werkseitig wurde ein F  hlerabgleich bei 25   C Umgebungstemperatur durchgef  hrt  Je nach Standort und ver   schiedenen Umgebungsbedingungen bestehen f  r jede Installation andere Einfl  sse auf die Vitrine und m  ssen  daher f  r eine korrekte Temperaturanzeige am Display 
32. ausgestattet  sodass lediglich die  Abwasserverbindungen oder externe Tauwasserverdunsterschalen entsprechend den   rtlichen Gegebenheiten  installiert werden m  ssen  Es muss sichergestellt werden  dass Abwasser nicht zur  ck in die K  hlstelle gelangen  Kann     Die Abwasserinstallation darf nur durch einen Installationsfachbetrieb  entsprechend DIN 1986 f  r  Abwasser  ausgef  hrt werden        24 Technische Anderungen vorbehalten Gultig ab Oktober 2014    7    IDEAL   KE        Technische Information    2 6  Vermeidung des gr    ten Fehlers bei der Installation    Die richtige Bel  ftung des K  hlaggregates bei steckerfertigen Ger  ten ist ein wesentlicher Punkt f  r eine ein   wandfreie Funktion der K  hlm  bel  Vom K  hlaggregat m  ssen die entzogene Energie des Warenraumes und die  durch elektrische Energieaufnahme entstandene Warme des Kompressors abgef  hrt werden   nur so kann der  Kaltekreislauf funktionieren     A  Kompressor  Der Kompressor pumpt das gasformige Kaltemittel durch die K  hlanlage     A  Kompressor  B  L  fter  C  Kondensator        B  L  fter Ventilator  Der Ventilator saugt kalte Raumluft an und k  hlt dadurch den Kompressor  und das heiBe Gas im Kondensator     C  Kondensator   Warmetauscher  in welchem die entzogene Warme des K  hlbereiches  wieder an die Umluft abgegeben wird  Gasf  rmiges Kaltemittel wird durch  die Warmeabgabe wieder verfl  ssigt     Vermeiden Sie  dass sich die erwarmte Abluft aus dem Gerat mit der kalten Luft aus dem Raum  
33. b Oktober 2014    Benutzerhandbuch    DEFEKT MOGLICHE URSACHE    Das Licht wurde nicht einge     Die Beleuchtung schaltet   funktioniert nicht  richtig    fallen     zu niedrige Temperatur in der    Vitrine    Kondensation an  den Gl  sern    zu hohe L  fterdrehzahl    Statusanzeigen und Fehlermeldungen am Display    Eine Leuchtstoffr  hre ist ausge     zu hohe Umgebungstemperatur  und zu hohe Luftfeuchtigkeit        ABHILFE    Dr  cken Sie die LICHT Taste an der Steuerung  f  r zirka eine Sekunde  Falls keine Abhilfe  ver   standigen Sie einen Techniker     Tauschen Sie die defekte L euchtstoffr  hre aus   falls keine Abhilfe  verstandigen Sie einen Tech   niker     W  hrend die SET Taste gedr  ckt ist  wird der  oollwert angezeigt   dieser sollte bei Vitrinen  ohne Isolierglas nicht unter 4 bis 5   C liegen      25   C Umgebungstemperatur und 60   relative  Luftfeuchtigkeit sollten nicht   berschritten wer   den   falls m  glich Klimaanlage einschalten     Verstandigen Sie einen Techniker     MASSNAHME    Untertemperatur  Temperatur unterhalb der Alarmgrenze aus    Kontrolle des F  hlers F1    Kontrolle des F  hlers F1    Kontrolle des F  hlers F2    Kontrolle des F  hlers F2    Heparatur Steuerteil    alle Parameter   berpr  fen    MELDUNG URSACHE      bertemperatur  Temperatur oberhalb der Alarmgrenze aus   Parameter A1   an Parameter A2   E IL Fehler an F  hler F1  Kurzschluss   E IH Fehler an F  hler F1  Bruch   EcL Fehler an F  hler F2  Kurzschluss   EcCH Fehler an F  
34. ber  cksichtigt werden     Beispiel  Durch Sonneneinstrahlung und erh  hte Umgebungstemperaturen kann die Temperatur innerhalb  der Vitrine h  her sein als am Display angezeigt      lt   EY   lt    s  43  S     S  E  N     o  2  c     D  E    Beispiel  In klimatisierten Raumen bei niedrigen Umgebungstemperaturen kann die Temperatur innerhalb der  Vitrine niedriger sein als am Display angezeigt     Welche Temperatur ist wirklich in der Vitrine        Platzieren Sie Thermometer auf allen Zwischenborden der Vitrine und messen Sie die tats  chliche Temperatur  im Prasentationsraum der Vitrine  Vergleichen Sie den Durchschnittswert der gemessenen Temperaturen mit der  Anzeige am Display    F  hren Sie einen F  hlerabgleich laut beiliegender Programmierungsanleitung durch   Parameter H12    Kalibrierung F  hler F1     Beispiel  Die durchschnittliche Temperatur in der Vitrine ist  7   C  das Display zeigt  4   C  somit erh  hen  des bestehenden Korrekturwertes um  3   Beispiel  Die durchschnittliche Temperatur in der Vitrine ist  3   C  das Display zeigt  5   C  somit verringern    des bestehenden Korrekturwertes um  2     ACHTUNG  Keine Messung wahrend der Abtauphase durchf  hren   Die Innentemperatur erh  ht sich   Produkt kern temperatur bleibt gleich     2 9  Instandhaltung    Tausch des Leuchtmittels    Da der Platz innerhalb des Lampengehauses sehr beengt ist  empfiehlt es sich  die gesamte Leuchte auszubauen   siehe dazu die Anleitung auf der nachsten Seite  Tausch des komple
35. breaker     Electric installation has to take place via a nominated specialist  The installation must comply with  the local electrical  health  and safety regulations        The connection to another voltage or frequency is not permitted     The installation of remote refrigerated units has to take place via anominated refrigeration specialist        Valid from October 2014 Technical changes reserved 61    Cold display cases    2 4  Information regarding refrigeration connection    All units are equiped with a coated evaporator coil  Expansion valves or capillary tubes are conneted with the eva   porator and all refrigeration lines and electric wiring lead out on the bottom of the insulated well     Self contained units  integral     Self contained units are ready to use  all components are fixed and the refrigeration system  is filled with refrigerant  Units with expansion valves come with sight glass with humidity  indicator  placed beside the condenser coil     The condenser unit is placed in a pull out stainless steel housing and offers easy access for  service and maintenance work  Take care that the loop of copper tube is not overstretched        Remote refrigeration    These units are prepared for connection in an existing refrigeration plant  the copper tubes are insulated and lead  through the foamed well on bottom  Expansion valve for the corresponting refrigerant is installed on the evaporator  and the system is filled with nitrogen    Components like solenoid val
36. bundk  hlanlage vorgesehen  Die Kupfer   anschlussrohre sind isoliert und durch die gesch  umte Kuhlwanne nach unten gef  hrt  Die Verdampfer sind  mit einem Expansionsventil f  r das gew  nschte K  ltemittel ausgestattet und mit trockenem Stickstoff gef  llt   Magnetventile  Filtertrockner und gegebenenfalls Saugdruckregler sind bauseits zu installieren  Die angegebene  Verdampfungstemperaturen sowie die Verfl  ssigungstemperaturen sind konstant zu halten  Dampfanteile vor  dem Expansionsventil sind zu vermeiden     Anschlussarbeiten    Alle Arbeiten  Installationen  Lieferungen und Leistungen d  rfen nur durch K  ltefachbetriebe und Fachpersonal  ausgef  hrt werden  Der Stand der Technik  die einschl  gigen rechtlichen Bestimmungen  Vorschriften und  Richtlinien von Beh  rden  Fachverb  nden und Berufsgenossenschaften m  ssen eingehalten werden    Die installierte K  lteanlage ist in Betrieb zu nehmen  und es ist eine Funktions  und Sicherheitspr  fung durchzu   f  hren  Das Protokoll ist dem Betreiber zu   bergeben     2 5  Hinweise zur Abwasserinstallation    Die Tauwasserentsorgung kann auf verschiedene Weise erfolgen   Verkaufsvitrinen   steckerfertig    Steckerfertige Verkaufsvitrinen  allseitig geschlossen   Kundenseite mit Glas und Bedienerseite mit T  ren  sind  mit vollautomatischer Tauwasserverdunstung ausgestattet     Verkaufsvitrinen   zentralgek  hlt und alle Vitrinen f  r Selbstbedienung    Alle diese Vitrinen sind werkseitig mit Geruchsverschl  ssen  Siphon  
37. chnical changes reserved Valid from October 2014    Technical information        2 6  Prevention of the most common error    Correct ventilation of the condensing unit of self contained display cases is very important for the correct and efficient  functioning of the display case  The condenser has to transfer the heat of the refrigerant  energy of the products   and the electrical heat of the compressor to the surrounding air in the room in order for the cooling process to    work     A  Compressor  B  Fan  C  Condenser        A  Compressor       B  Fan    C  Condenser    hot refrigerant     the room        The compressor pumps the refrigerant through the cooling system     The condenser fan draws fresh air in from the room and passes it through  the compressor expels the hot air out of the condenser     The condenser coil is referred to as heat exchanger and cools the returning    Don t allow warm air retourning to the room to re circulate and remix with cooler air coming in from    All self contained units come with a moveable s s compressor housing  This offers the possibility to locate the  condenser face near the air grill  air in  of the counter to avoid cirulation     Air grill of the counter facing is less than 5 mm away  from the condenser coil        Air grill for cold  incoming air     gt     Face ofthe con     denser coil Sacloap ber  ween condenser   housing and   Removable counter facing   Air grill Close gap on all    four sides with  self adhesive  sealing ta
38. chnische Informationen    Teil    B    K  hlvitrinen    E Schaltschema           K  hlvitrine     zentralgek  hlt  Gastro  Gastro HCG  BAK und Green Modelle    SUB D 9 pole                                                                                                                                                                                                                                                                                       5 Ee   o  0          K  hlstellenregler            9       9 S    A   ST501 KU3     o Lu o S      230V  230V  230V  230V       0 24V         DO    m    I   I         Legende    N PE L NI  PE    KUHL VITRINE    M3   L  fter Verdampfersatz    S1   L  fter Steuerung    WM   Raumf  hler K  hlung    c     Verdampferf  hler     amp     Beleuchtung K  hlung    X   Magnetventil NETZ    230V 50H2 NV  AM    Rahmenheizung  bauseits    RAHMEN LICHT  i HEIZUNG  Wi 8 Ld  N e e    PE e    2 222020    nom nn nn nn nn nn i mann oo on onen a nn    E Sch    altschema     K  hlvitrine HCO   KR     steckerfertig ohne Nachlaufrelais    SUB D 9 pole                                                                            we                aR SB RR IIT Se EE el re EU PM D DECRE SE TOE ga EE EE ee DCN AUR Ne PN BEE SEE SE ERROR NUN E TUN T GENE                                                                                                                                                                                                                        
39. cksichtigen     Gultig ab Oktober 2014             EINFACHE REINIGUNG       ni  uii    Technische Anderungen vorbehalten        Montage und Einbauanleitung     Hinweise    J    Bedienteil f  r Montage in  M  belfront abnehmbar  spritzwassersicher  stufenlos regulierbarer  Luftstrom       TAUWASSERENTSORGUNG    N  A  9 jn         ber das   rtliche Kanalnetz  mittels einer Tauwasserschale m   zur manuellen Entsorgung  Zubeh  r   I  durch eine elektrische Tauwasser   verdunsterschale  Zubeh  r   vollautomatische Tauwasser   verdunstung bei geschlossenen Vitrinen  nur steckerfertig            Hebeverdampfer f  r leichte Reinigung des Verdampfers  und der Innenwanne mit Wasser oder Handbrause  Glaser  leicht kippbar  leicht zu reinigen    Filter sch  tzt vor Beschadigung   Verschmutzung und Verletzung  leichte Reinigung im  Geschirrsp  ler    21                  AL   K E       Technische Informationen    Teil    K  hlvitrinen    2  Montage und Einbauanleitung  fur den Kaltefachhandler und Kaltetechniker    2 1  Erste Schritte      bernahme    Kontrollieren Sie das Ger  t auf Transportsch  den und notieren Sie festgestellte Sch  den auf den   ber   nahmepapieren des Spediteurs sowie auf Ihrem Formular und lassen Sie sich den Schaden best  tigen  Falls der  Schaden erst nach dem Auspacken auftritt  sind Sie verpflichtet diesen unverz  glich schriftlich mitzuteilen  Eine  vorherige telefonische Mitteilung an Ihren Lieferanten ist ratsam     Bei nicht fristgerechter Meldung eines Tran
40. d display cases are equipped  with adjustable base decks  Because of the deep refrigerated  well you have the possibility to represent your products in diffe   rent heights  with straight or slant base decks  or without decks   example for beverages     Certainly you can also use Gastronorm containers for these  models  GN 1 1 pans can be placed directly into the weel   Smaller pans need optional adapter bars  lenghtwise and cross                                                                                                                                                                                                                                                                                                                        no     see figure on left side   Divisional bar    1 6 cross   325mm      E     You can use Gastronorm pans with a maximum depth of 150          Gastronorm pan l  1 9  NS on 1 1 um   Divisi Ib Divisi Ib          ee eg A flexible combination of GN pans  adjustable base decks and    1 2  outside     1 1  middle                                                                                                                                                                                                                                                                                                                                                                                                  50    Technical changes reserved    storage inside the wel
41. der erw  nschte K  hlraumtemperatur  Sollwert   Temperatur  um     Eine Veranderung der Sollwert Temperatur ist nur mit  der gleichzeitigen Betatigung der Tasten SET und AUF  beziehungsweise SET und AB m  glich  W  hrend der  Tastenbet  tigung kann man den ver  nderten Sollwert  in der Anzeige ablesen  Nach der Ver  nderung der  Sollwert Temperatur und Loslassen der Tasten erscheint  in der Anzeige wieder die Istwert Temperatur  Das ist die  Standardwert Einstellungsmethode     Die Bet  tigung der Taste STANDBY w  hrend des Betriebes   mindestens drei Sekunden  schaltet den K  hlstellenregler  ab  in der Anzeige erscheint die Meldung AUS  Ein Wieder   einschalten des Reglers ist mit der nochmaligen Betatigung  der Taste STANDBY m  glich     Die Tasten AUF und AB erf  llen neben der Aufgabe der  Werteinstellung noch weitere Funktionen  Die Bet  tigung  der Taste AUF f  r drei Sekunden l  st eine au  erplanm    ige  Abtauung der K  lteanlage aus  Die Bet  tigung der Taste  AB kann bei einem eventuellen Alarm  Summerton  f  r die  Quittierung des Summertons verwendet werden     G  ltig ab Oktober 2014    R    IDEAL   KE        Technische Information      bersicht der Softwarefunktion    Die K  hlungssteuerung ist vom Werk seiner gew  nschten Spezifikation ent   sprechend eingestellt  Sie sollte keiner Justage ben  tigen          Wenn n  tig sollte sie ausschlie  lich von einem qualifizierten Kaltefachmann    justiert werden     OLO  3 Sek  Der Zugang zur USER Ebene ist durch ein
42. displayed here  The factory setting for the tempera   ture is  5   C    After switching on the empty appliance it can take up to 3 hours  until the desired temperature is reached  If the appliance is filled  with goods this time can be extended up to 24 hours  The time until  reaching the set temperature will also be influenced by the environ   mental conditions  room temperature and humidity         Key 1 SET Key Displays set point   Key 2 LEFT Key Reduction of the desired set point temperature  Key 3 RIGHT Key Increasing of the desired set point temperature  Key 4 O l Key Exit configuration menu  stand by mode    The desired temperature can be set within the range from  2   C up to  8   C  The set point temperature can be  displayed by pressing Key  1   Simultaneously pressing of Key  1 and Key  2 will lower the desired temperature   respectively the temperature will be risen by pressing of Key  1 and Key  3      After resetting the temperature needs some time to pass before the desired temperature has been achieved   Please check the interior temperature a few hours afterwards with an exact thermometer and reset the thermostat  if needed  The temperature setup should be made by a specialist during installation     8 2  Loading restrictions for the refrigerated base    The interior is designed for the storage of beverages and packed and loose foodstuff of all kind  This does not  apply to seafood  especially clams  Foods with high acid part  like salads  vinegar  fish and s
43. e 59  2  Installation and start up instruction   for authorized refrigeration companies and   qualified service personnel 60  2 1  First steps 60  2 2  Installation of the controller display 61  2 3  Information regarding power connection 61  2 4  Information regarding refrigeration connection 62  2 5  Information regarding water and drain connection 62  2 6  Prevention of the most common error 63  2    Air ventilation 64  2 8  Calibration of the sensor 65  2 9  Maintenance 65  er Maintenance and Service 66  3 1  Service notes 67  3 2  Spare parts 67  4  Programmable digital refrigeration controller 68  4 1  Programming instruction   Refrigerated display cases 68  9  ochematic circuit diagram 71  6  Declaration of conformity 74    43    Cold display cases    1  Introduction    1 1  Welcome    With the purchase of this new refrigerating equipment you have decided on a product that combines the highest  technical demands with practical service comfort  We recommend that you read these operating and maintenance  instructions carefully in order to become familiar with the product quickly     Before you start the refrigerated display case  please read the regards and instructions in this manual     Take yourtime to read the user manual  it is worth your investment  The indicated instructions here  general and  technical  will help you to keep your device in an optimal operating condition for a long time     Unfortunately a manual can not consider all eventualities  Do not hesitate
44. e hier enthaltenen Anweisungen   allgemeine wie auch  technische  werden Ihnen helfen  Ihr Ger  t dauerhaft in einem optimalen Betriebszustand zu halten     Es liegt in der Natur der Sache  dass ein Handbuch nicht alle Eventualit  ten ber  cksichtigen kann  Z  gern Sie  nicht im Falle von Unklarheiten bei der Installation  im Betrieb oder bei der Wartung  Kontakt mit Ihrem H  ndler  aufzunehmen  Oft lassen sich Fragen durch einen kurzen Telefonanruf kl  ren     Bei sachgerechter Behandlung werden Sie lange Freude an diesem Ger  t haben  F  r anfallende Wartungs  und  Reparaturarbeiten sollten Sie diese Bedienungs  und Einbauanleitung sorgf  ltig aufbewahren     12  Garantie und Haftung    Im Grunde gelten unsere    Generellen Zahlungs  und Lieferbedingungen     Anspruch auf Garantie und Haftung  f  r Personen  und Besitzsch  den sind unm  glich  wenn diese auf einen oder mehrere der folgenden Gr  nde  zur  ckzuf  hren sind     unsachgem    e Verwendung des Ger  tes  Sch  den welche durch den Transport entstanden sind    Betrieb des Ger  tes mit defekten Sicherheitsbauteilen oder Sicherheitsbauteilen  die nicht ordnungsgem      installiert wurden und nicht arbeitsf  hig sind    Nicht Einhalten der Hinweise der Bedienungsanleitung bez  glich der richtigen Installation  Inbetriebnahme   Betrieb  Wartung und Montage des Ger  tes    nicht autorisierte mechanische oder technische   nderungen am Ger  t  unzureichende Wartung der Nutz  und Verschlei  teile   nicht autorisierte Repara
45. eafood must be  packed in containers  closable boxes or vacuum packed     Unpacked food  highly acidic  will destroy the evaporator coil and causing corrosion on the stain   less steel        Please pay attention that the goods are not placed to tight to the evaporator or block the ventilation openings  The  air circulation slots of the drawer must not be blocked by the goods completely  Else an optimal cooling of the  goods will not be assured  Also when using GN containers please take care not to overload them  particularly near  the exhaust openings of the evaporator     The inside temperature of the unit is much more sensitive to changes than the stored goods  Their temperature  will change with more delay  That means that by loading the unit with not pre chilled goods the thermometer may  display the desired temperature although the temperature of the goods is not the desired one yet     Avoid too low temperature in the storage drawer or door element  beverages could freeze and burst the bottle       52 Technical changes reserved Valid from October 2014    7    IDEAL   K E        User manual    9  Cleaning and care    The following is advice on maintenance  care  trouble shooting and service for your refrigerated display cases  The  interior and the outside of the unit have to be cleaned every day in accordance with hygiene regulations  Only then  can you guarantee optimal presentation of the goods     CAUTION   Before you start to clean and care switch off the appliance
46. echnical information    3 1  Service notes    In order to guarantee efficient operation of the refrigerated display case along with optimum presentation of the  goods  the entire technological equipment has to be checked and maintained regularly     Service and maintenance  troubleshooting    Prescribed adjustment  service and inspection work is to be completed timely by the manager or if necessary  by an authorized service technician     The operating personnel are to be informed before the beginning of the maintenance and service work     The unit is to be disconnected from the mains before maintaining  inspecting and repairing is performed  the  main switch is to be guarded against unintended reclosing     Check all screw connections for tight fitting   After finishing maintenance check all safety devices for proper functionality          Following actions can be done by the operator      S   complete cleaning of the entire refrigerated well E   checking the ventilator for functionality E   checking the temperature of the cabinet and of the goods E   checking and cleaning the drainage lines and drip water evaporation    cleaning the condensers on the cooling unit periodically Part    The condenser coil must be clean all the time  regular cleaning   A dirty condenser is the main  cause of refrigeration overheating  burnout compresso and poor cooling levels         Following actions can be done by the service technician     checking the thermostat setting  checking the amoun
47. edienteil  Display  und der  Leistungselektronik  Beides ist im Geh  use der Steuerkonsole  eingebaut    Das Bedienteil ist intern durch ein 2 Meter langes SUB D mit der  Leistungselektronik  Platine  verounden     Das Bedienteil ist abnehmbar und kann bis zu 2 Meter entfernt  von der Steuerkonsole in der M  belfront montiert werden   Der n  tige Ausschnitt f  r das Display betr  gt 87 5 x 56 5 mm         lt   U   lt      oO  4  S  E  s  E  U   lt      2      lt            2 3  Hinweise zum Elektroanschluss       Die Vitrinen sind elektrotechnisch komplett ausgestattet und installiert  Der K  hlstellenregler ist fertig eingestellt  und betriebsbereit  nach erfolgter Installation muss der Parameter H12  Kalibrierung F  hler F1  kontrolliert und  notfalls an die vorhandenen Umgebungskonditionen angepasst werden   siehe F  hlerabgleich   auf Seite 26    In Sonderf  llen werden die Vitrinen kundenspezifischen W  nschen entsprechend f  r den Anschluss an externe  K  hlstellenregler vorger  stet geliefert     Die Ventilatoren der Umluftk  hlvitrinen k  nnen   ber den K  hlstellenregler STORK ST501 drehzahlgeregelt  werden  siehe entsprechende Programmieranleitung   Diese Einstellung sollte ausschlie  lich von einem qualifi   zierten Fachmann durchgef  hrt werden     Anschluss des Kuhlmobels  Ein steckerfertiges Gerat kann vom Betreiber selbst angeschlossen werden  Es wird  mit einem standardm    ig 1 5 Meter langen Anschlusskabel mit Schutzkontaktstecker geliefert  Der Anschluss  e
48. eeinflusst        Taste 1 SET oollwertanzeige   Taste 2 LINKS Verminderung der gew  nschten lIst  Temperatur  Taste 3 RECHTS Erh  hung der gew  nschten Ist T emperatur  Taste 4 O I Konfigurationsmen   verlassen  Stand by Modus    Die Temperatureinstellung ist im Bereich von  2   C bis  8   C m  glich  Der Sollwert kann durch Bet  tigung der  Taste  1  angezeigt werden  Durch gleichzeitiges Drucken der Taste  1  und der Taste  2  kann die gew  nschte  Temperatur vermindert beziehungsweise durch Dr  cken der Taste  3  erh  ht werden    Nach einer   nderung auf die gew  nschte Ist Temperatur dauert es einige Zeit  bis diese erreicht wird  Pr  fen Sie  erst einige Stunden sp  ter die Temperatur im Innenraum mit einem genauen Thermometer und verstellen Sie das  Thermostat eventuell neu  Die Temperatureinstellung soll m  glichst bei der Installation durch den Fachh  ndler  erfolgen     8 2  Best  ckung Kuhlunterbau    Der Innenraum ist f  r die Lagerung von Getr  nken und verpackten Lebensmittel aller Art konzipiert  Im speziellen  Lebensmittel  welche s  urehaltig sind  wie Salate  Essig  Fisch und Meeresfr  chte  m  ssen in jedem Fall vakuum   verpackt oder in dicht abschlie  enden Behaltnissen aufbewahrt werden     Unverpackte Lebensmittel k  nnen durch aggressive D  mpfe den Verdampfer zerst  ren        Achten Sie besonders darauf  dass die Ware nicht zu nahe am Verdampfer steht und die Luft  ffnungen verdeckt   Dadurch w  re eine optimale Durchk  hlung der Ware nicht m  glich 
49. eh  use heraus  um die Clips und  den Beleuchtungsbalken zu l  sen   Halten Sie den Beleuchtungsbalken  dabei fest     Verbinden Sie nun den Lampen     stecker mit dem neuen Beleuchtungs     balken  Dr  cken Sie den Beleuch   tungsbalken in die Clips bis er  einrastet        b4   U mm  Danach kippen Sie dieT  re  und l  sen Sie diese aus der  oberen F  hrungsschiene        Ziehen Sie den Stecker aus dem  Beleuchtungsbalken heraus  um den  Balken mit den Clips abnehmen zu  k  nnen        Schlie  en Sie nun die Vitrine wieder  am Stromnetz an und   berpr  fen  Sie die Beleuchtung auf ihre Funktion        Den ganzen Vorgang wie   derholen Sie auch mit der  rechten Schiebet  re        Beim Einbau der Schiebe   t  ren beginnen Sie mit der  rechten T  re und schieben  diese in angewinkelter Hal   tung in die obere F  hrungs   schiene ein  Auf dem Bild zu  sehen die Einf  hr  ffnung f  r  die Rollen     28    Schieben Sie die T  re  durch leichtes nach oben  Dr  cken  mit links rechts  Bewegungen hin un her bis  Sie die Einrastschlitze f  r  die Rollen ertasten     Danach heben Sie die T  re  leicht an bis die untere  F  hrungsschiene der T  re  in die Laschen am Rahmen  der Vitrine eingerastet sind     Technische   nderungen vorbehalten    Wiederholen Sie mit der  linken T  re die vorherigen  Einbauschritte     G  ltig ab Oktober 2014    7    IDEAL   KE        Technische Information    3 1  Wartungshinweise    Um eine einwandfreie Funktion der K  hlvitrine und eine optimale Warenpr
50. enden    tzenden  l  sungsmittelhaltigen  bleichenden oder chlorhaltigen  Reinigungsmittel   Verwenden Sie niemals Hochdruck   Wasserdruck  oder Dampfdruckreiniger    Verwenden Sie keine entflammbaren  chemischen Reiniger    Benutzen Sie niemals Scheuermittel  Scotch  Reinigungsvlies  oder Stahlwolle     G  ltig ab Oktober 2014 Technische   nderungen vorbehalten 15    7    Benutzerhandbuch    Teil    K  hlvitrinen    9 3  Spezielle Anmerkung f  r die Reinigung    9 3 1  Reinigung des Innenraumes und des Verdampfers    Entfernen Sie die Einlegeb  den bzw  GN Schalen  Bild 1  und Luftleitbleche  Bild 2  nach oben aus der K  hlvitrine  und klappen die Verdampferabdeckung  Bild 3  hoch  Der komplette Verdampferkasten und die Lamellen  des Verdampfers k  nnen mit einer Handbrause abgesp  lt werden  Bild 4   Durch den Einsatz von L  ftern in  Niederspannung  24 V  besteht kein elektrisches Gefahrenpotenzial  Klappen Sie den Verdampferkasten hoch bis  die Arretierungslasche  Bild 5 und 6  links einrastet   jetzt ist der Verdampfer fixiert und Sie k  nnen den ganzen  Innenraum reinigen  Entfernen Sie zuerst den gr  beren Schmutz  damit der Abfluss nicht verstopft wird        ACHTUNG  Pr  fen sie vor der Reinigung  ob das zur Reinigung verwendete Wasser auch abgeleitet werden  kann  Wenn das K  hlm  bel nicht direkt an den Kanal angeschlossen ist  m  ssen Sie notfalls ein Gef     ent   sprechender Gr    e unterhalb des Abflusses stellen     Der Verdampfer und die Wanneninnenseite sind
51. enseitig Panoramascheibe isoliert  Seitenscheiben iso   liert  Standvitrine mit Unterbauk  hlung zur Bevorratung       8 Technische   nderungen vorbehalten G  ltig ab Oktober 2014    7    IDEAL   KE        Benutzerhandbuch       2  Verwendungszweck    Die K  hlvitrinen sind speziell f  r den Einbau in Lebensmittel  und Ausgabetheken entwickelt worden  Sie sind f  r  die K  hlung und Pr  sentation von Lebensmittelerzeugnissen und Getr  nken bei regelbaren Temperaturen von     4   C bis  12   C geeignet  E     Diese K  hlger  te sind nicht geeignet um Lebensmittel abzuk  hlen  Alle zur Pr  sentation gebrachten    Produkte mussen mit der fur sie vorgeschriebenen Temperatur eingebracht werden  E  S  Wir empfehlen die K  hlvitrine bei Nichtgebrauch au  erhalb der Betriebszeiten abzuschalten  Bevor Sie die 3  K  hlvitrinen best  cken  warten Sie  bis die gew  nschte Temperatur erreicht ist   Teil    F  llen Sie nie zuviel und nie zu warme Ware ein        3  Bestimmungsgemdfse Verwendung    Die K  hlvitrinen entsprechen dem aktuellen Stand der Technik und sind entsprechend den anerkannten sicher   heitstechnischen Vorschriften gebaut und betriebssicher  Dennoch k  nnen bei deren Verwendung Gefahren  f  r Gesundheit und oder Leben des Benutzers oder Dritten bzw  Beeintr  chtigung des Ger  tes und anderer  oachwerte entstehen  wenn es von unausgebildetem Personal unsachgem     oder zu einem nicht bestimmungs   gem    en Gebrauch eingesetzt wird     Das Ger  t darf nur in technisch ein
52. er 2014        Benutzerhandbuch Okre    Vitrinen mit Tortenauszug    Die Kuhlvitrinen der Modelle BAK L und BAK KSL sowie GREEN L und GREEN  KSL sind durch ihre leichte Best  ckung mittels Tortenauszug bestens f  r die  Pr  sentation gro  er Torten oder   hnlicher Produkte geeignet                  Zur Reinigung des Verdampferraumes muss als erstes die Tortenlade aus  der Vitrine entfernt werden  Bild 1   Die Lade bis zum Anschlag herausziehen   danach zirka 5 cm anheben damit die Lade ausgeh  ngt werden kann  Bild 2    Rollen der Teleskopschienen     Danach die hintere Blechabdeckung aush  ngen  Bild 3  und den Verdampfer  anheben und mitfixieren  Bild 4     Verriegelungsstift an der linken Seite   Die  Bodenwanne unterhalb des Verdampfers kann nun gereinigt werden     Es ist wichtig  alle Vitrinent  ren bei Nichtbenutzung geschlossen zu halten  Bei nicht vollst  ndig  geschlossenen T  ren ist es nicht m  glich eine gleichbleibende Innentemperatur zu bewahren        H  henverstellung der Zwischenborde    Ihre Vitrine bietet die M  glichkeit  die Zwischenborde in H  he und Neigung zu verstellen  Dadurch kann die  Pr  sentation der Produkte optimal an ihre Bed  rfnisse angepasst werden  Die Glaszwischenborde k  nnen um  eine Stufe    25 mm  von der Mittelposition verstellt werden     Entfernen der Glasborde   Bevor die Tr  ger verstellt werden  sollten Sie  das Glaszwischenbord entfernen   Daf  rmuss das Glasbord an der Vorderkante  angehoben werden  bis dieSicherungslasche  u
53. er Neubeschaffung diverser Teile an die f  r das Ger  t zust  ndige K  ltefachfirma   Ersatzteile k  nnen nat  rlich auch   ber jeden beliebigen Fachh  ndler in Ihrer N  he bezogen werden     Jedes Ger  t ist mit einem Typenschild versehen  Es befindet sich unterhalb des Steuerungsgeh  uses  Unter   seite  oder seitlich am Ger  t  Geben Sie die angef  hrten Ger  tedaten Ihrem K  ltefachmann bekannt     Besonders die Typenbezeichnung des Ger  tes und die Seriennummer bzw  das Herstellungsdatum sind f  r  die Zuordnung und die schnelle Abwicklung erforderlich     Beispiel  Typenbezeichnung  Gastro GE 80 53 E  Seriennummer  419001_EU331050_001    Die Seriennummer besteht aus  Auftragsnummer Artikel Nr  Anzahl der Ger  te    G  ltig ab Oktober 2014 Technische   nderungen vorbehalten 29    K  hlvitrinen    Elektronische Steuerung    Programmieranleitung     K  hlvitrine    4   4 1     Kuhlstellenregler  Produkt  und Programmierbeschreibung    f  r alle K  hlstellentypen geeignet  Abtauregelkreis frei konfigurierbar  Umluft   Elektro   Hei  gas Abtauung  L  fter Regelkreis   vordefinierte Parameters  tze       Produktbeschreibung    Der mikroprozessorgesteuerte Regler ST501 KU3KAR 112FP verf  gt Uber ein Bedienteil und eine separate  Netzteilplatine und wird f  r thermostatische Temperaturregelung von einfachen K  lteanlagen verwendet  Er wird  mit 230V AC versorgt und hat vier Ausgangsrelais sowie einen Ausgang f  r Gleichspannungslufter    Die Relais k  nnen f  r verschiedene Fun
54. ftung erfolgt in einer Linie durch das K  hlaggregat hindurch  Kundenseitig ist eine Abluft  ffnung  erforderlich  Sollte die Kundenseite der Theke ohne   ffnungen sein  muss die Abluft seitlich der Theke oder an  der Bedienerseite abgef  hrt werden     Variante 1  Variante 2   Luftstrom direkt durch das K  hlaggregat  gerade in Luftansaugung und Warmluftauslassoffnung auf  einer Linie ausgeblasen derselben Seite       Pa FN IRR   ooo 2 vp       Lem E       PELL LALL LAL LLALA L OL ELLE L EL OLE LEL L LEL ELE LOE EL RAL ALLL OE EL LOL EL LLG                           RANA                RSS SRA RE RIN RAIN RAM EERUN TYN          Welche Methode Sie auch verwenden  stellen Sie sicher  dass die eintretende kalte Zuluft nur durch die  Kondensatorflache nach innen gelangt und keine warme Abluft vom Innenraum der Theke angesaugt wird     Wenn die Abluft nicht durch einen Luftkanal nach au  en gef  hrt wird  kann ein zus  tzlicher Abluftventilator helfen   die warme Abluft vom Thekenunterbau hinaus zu bef  rdern  Speziell bei Variante 2 ist dadurch eine bessere  K  hlung des K  lteaggregates gegeben     Bei Be  und Entl  ftung auf einer Seite  Variante 2  soll der Abstand zwischen den L  ftungs  ffnungen so gro   als  m  glich sein  um ein Ansaugen der warmen Abluft zu verhindern     Achten Sie darauf  dass die Ansaug  ffnung und die Luftauslass  ffnung gro   genug sind  Der Luftstrom darf nicht  unterbrochen oder behindert werden  die warme Abluft muss ungehindert aus dem Aggregatr
55. gy  electrical installa   tion  water connection and mechanical work    Any adaptation is to be authorized by the manufacturer        Those covers bearing a warning may only be opened by specialists   The bottom and back panels are not to be cleaned by water jet   Protective covers and devices may not be removed due to risk of injury   The control system may only be opened by an expert     Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are to be avo   ided  in order to ensure the efficient functioning of the refrigerating unit     The surrounding temperature may not exceed 25   C  the relative humidity may not exceed 60   over a long  period of time     All displayed goods must have a core temperature from  5    or below when they are loaded into the cabinet  Due to risk of injury  sharp objects are not to be stored loosely in the refrigerating unit   Any glass parts are to be treated with the necessary care in order to avoid injuries resulting from broken glass     Components and operating equipment may only be replaced by original parts     1 5  Ongoing development    AKE reserves the right to change specifications and construction  as part of ongoing product improvement     Valid from October 2014 Technical changes reserved 45    Cold display cases    1 6  Validity    These operating instructions are valid for the following models  self contained and remote refrigerated      Gastro und BAK    G     Customer side closed 
56. halb der   ffnungszeit ausgeschaltet bleiben     9 1  Generelle Empfehlung    Das Ger  t muss t  glich gereinigt werden   Tragen Sie s  urebest  ndige Handschuhe um Hautreizungen zu vermeiden     Nach dem Reinigen mit Spezial Reinigern m  ssen alle Teile mit klarem Wasser abgesp  lt und anschlie  end  getrocknet werden  damit keine R  ckst  nde bleiben    Es ist absolut notwendig auf einige grundlegende Dinge zu achten  damit dieses Edelstahlprodukt lange und  einwandfrei arbeitet       Halten Sie die Edelstahl Oberfl  che stets sauber     Achten Sie darauf  dass immer genug Frischluft auf die Oberfl  che kommt     Ber  hren Sie die Oberfl  che niemals mit rostigem Material     9 2  Reinigungsmittel    Verwenden Sie folgende Reinigungsmittel        Lauwarmes Seifenwasser  Verwenden Sie f  r alle Fl  chen  die direkt mit der Ware in Ber  hrung kommen  nur  lauwarmes Seifenwasser     Glasreiniger  Entfernt Fett von Glasoberfl  chen  Die Glasscheiben lassen sich alle anheben  sodass ein m  he   loses Reinigen der Scheiben und der darunterliegenden Fl  chen m  glich ist     Edelstahlreiniger  Die Edelstahloberfl  chen der K  hlm  bel sollten mit handels  blichen Edelstahlpflegemitteln  behandelt werden     Lampen  Nur mit einem weichen Tuch oder Lappen reinigen     Laden und GN Beh  lter  Zum Reinigen leicht herausnehmbar  ohne Wekzeug   Verwenden Sie B  rsten mit  Plastik  oder Naturborsten     Vermeiden Sie folgende Reinigungsmittel NICHT        Verwenden Sie keine scharf riech
57. he control hysteresis   A small hysteresis enables exact control  but will result in frequent switching of the relay     d  Defrosting interval    he defrosting interval defines the time after which a defrosting operation is started  Once the defrosting  operation is triggered  the defrosting interval starts again  A defrosting operation can also be triggered by  pressing the UP button     manual defrosting   for at least 3 seconds or another parameterised button  Via the  internal week timer  defrosting can also be started in real time  Once switched on  the controller starts  refrigeration immediately and will trigger the first defrosting operation as soon as the time set in d    has elapsed  If   d  O   no automatic defrosting operation will be performed     dc Defrosting mode   In this parameter  you can define if defrosting is to be performed and  if yes  how it is to be performed    You can choose among simple shut down of the compressor  defrosting by electric heating or by hot gas   Electric defrosting will always be performed after a compressor break  defined in dg  Hot gas defrosting will  always be performed directly after a refrigeration phase  Additionally  you can define via parameters d    and dB if  the cold store temperature is to be lowered before defrosting     d  Defrosting temperature  A defrosting operation is complete as soon as the temperature set here is reached at the evaporator   If the defrosting operation is not completed within the time set in a 
58. hler F2  Bruch   EPJ Interner Fehler Steuerteil   EP a Fehler im Parameterspeicher   Erg Fehler im Datenspeicher    Heparatur Steuerteil    oind die angef  hrten M  glichkeiten nicht Ursache der aufgetretenen St  rung  wenden Sie sich bitte an Ihren    Kundendienst        G  ltig ab Oktober 2014    F  r Warenverluste ist nicht der Hersteller haftbar  auch dann nicht  wenn das Gerat noch unter  Garantie steht  Daher empfiehlt es sich  die Temperatur Ihres Ger  tes periodisch zu   berpr  fen     Technische Anderungen vorbehalten 19    T    AL   K E       Benutzerhandbuch    Teil    K  hlvitrinen    11  Gefahren    1 1  Elektrische Energie    Bei St  rungen in der elektrischen Energieversorgung Gerat sofort abschalten    Arbeiten an elektrischen Anlagen oder Betriebsmitteln d  rfen nur von einer Elektrofachkraft oder von unterwiese   nen Personen unter Leitung und Aufsicht einer Elektrofachkraft  den elektrotechnischen Regeln entsprechend   durchgef  hrt werden     ACHTUNG STROMSCHLAG   Kein FlieB  oder Strahlwasser in den Bereich von Elektroanschluss oder Gerateblende bringen        Gerate und Anlagenteile  an denen Inspektions   Wartungs  und Reparaturarbeiten durchgef  hrt werden  m  ssen  spannungsfrei geschaltet werden  Die freigeschalteten Teile zuerst auf Spannunggsfreiheit pr  fen  dann erden und  kurzschlieBen  Benachbarte  unter Spannung stehende Teile isolieren     ACHTUNG VERLETZUNGSGEFAHR   Bei Inspektions   Wartungs  oder Reperaturarbeiten muss das Gerat erst spann
59. ibility to adjust the shelves in height and angle  tilt able    This allows you various presentations of the goods  You can adjust the shelves 1 step up and down    25 mm   from the centre position     Remove the glass   Before moving the shelf to another position  please remove the glass  Therefore lift up  the glass on customer side until the s s lug   U profile protection on the glass  slips out  from the bracket   see pictures on right side         Move the brackets  The shelf brackets are fixed with 2 tabs in the  slots  Upper tab is equipped with 2 notches  for level or slant position    Lift up the bracket    Draw out the brackets  Insert the bracket in the new position       Choose level slant position    Valid from October 2014 Technical changes reserved 51         AL   KE       User manual    Part    Cold display cases    Freestanding combination displays with refrigerated base    The freestanding combination displays BAK KSL and Gastro KSV  and also GREEN KLS and GREEN KSV come  with a refrigerated base with fan blown air refrigeration for storage  Depending on the order  the refrigerated base  is delivered with doors and shelves  standard  or with optional drawer elements for GN containers      8 1  Setting the temperature of the refrigerated base    The refrigeration unit is switched on or off by pressing the green  main switch  Beside the main switch the digital display of the con   troller is arranged  The set point temperature and possible error  messages are 
60. int  temperature and releasing thebuttons  the actual temperature is dis   played again  This is the standard setting method     Please note that the setpoint can only be changed within the setpoint  limits     Access to User setting    To activate parameterisation mode  press buttons UP and  DOWN at the same time  After approx  3 seconds  the  code word Adr will be displayed  Press UP or DOWN to  switch between code words PH  Adr  USr and US  All other  settings   value specifications in parameter setting mode are perfor   med using the default value setting method  i e  pressing buttons SET  and UP or SET and DOWN at the same time     To offer an easy handling of the control unit  the most commonly used  parameters are collected in the USER level     L5r USER LEVEL    By selecting code word Hr and entering the correct password  a list  with predefined parameters is opened     These parameters are       5 d idg  dd  FB  F9  Hic  He   andl     Valid from October 2014 Technical changes reserved      9          n Passwort    Jer ha   gt    p   n     lt       D     j  1         TORORO OMORO   gt U             gt     J  5         amp    Pu  OU OUOU     My       AL   KE    Access to USER level requires a password   this is shown in the  enclosed programming instructions             n Passwort         69    7       Technical inforamtion    Part    Cold display cases    Description of functions  LIS USER LEVEL    c5 Control circuit 1  Hysteresis  In this parameter  you can specify t
61. ion and maintenance regulations    After cleaning the appliance is to be checked for any loose connections  shears and damages  Any defects found  should be repaired     The appliance is not to be used for non operating purposes  Any changes to the appliance are to be made solely    by the manufacturer  When replenishing the refrigerant only use the refrigerant indicated on the label  Refilling is  only to be carried out by authorized service personnel     4  Improper use of the unit    The refrigerated displays are not suitable for chilling foods  No foodstuffs having a higher temperature than indi   cated are to be filled into the tubs  Safe operation at temperatures of less than  2   C is not possible     The ventilation ducts in the front and back plenum of the presentation area may not be covered as doing so will  cut off the air circulation and result in prevention of the cooling function     5  Safety notes    All safety regulations were followed during manufacturing  particularly the VDE regulations  Association for  Electrical  Electronic  amp  Information Technologies  and international CEE regulations  The appliance was subject to  a comprehensive final check at the plant     Valid from October 2014 Technical changes reserved 47    Cold display cases    6  Fundamental operating notes  6 1  Start up    After placement or moving the refrigerated display  wait at least two hours before starting  This rest period is  needed for the oil to run back into the compressor i
62. ion the air plenums with the hanging tracks and drop in the base decks or GN con   tainers     Never clean the outside of the refrigerated well with a water hose or an abrasive sponge  Avoid flowing water  near these areas     All other surfaces can be cleaned with soft detergents or water     Each self contained refrigeration unit requires periodic cleaning of the condenser unit  The condenser coil  looks  like a radiator and is directly in front of the fan  on operators side  requires periodic cleaning  A dirty condenser is  the main cause of refrigeration overheating  burnout and poor cooling levels     oimilar to the daily merchandise area cleaning  it is necessary to remove the static dust build up from the conden   ser coils to ensure effective and trouble free operation     5A Technical changes reserved Valid from October 2014    7    IDEAL   K E        User manual    Condenser cleaning instructions    Remove air grill louver in front of the condenser coil     Remove the dust from the condenser coil  this can be done with  either a brush or a vacuum     Be careful and don t bend the lamellas   Heplace the air grill panel       Please assure that the air in and air out openings  grille  for ventilation are never blocked        S  3  CAUTION  S  The lamellas of the condenser coil are very thin and sharp  Avoid direct contact to prevent injuries  s  5  Part  9 3 2  Glass cleaning instructions A    Tilt able front and cover glasses for easy cleaning  Picture 1 and 2  in  a
63. isplay don t Call authorized service personnel   work     Close the doors and test the temperature after  One or more doors are open   30 minutes again   ZaDNDIN TS Cao Remove blockage  air vents must be kept free   blocked   Tea ood  Add only pre chilled food and do not overload  the unit   Set point too high  Set to desired temperature   Ambient temperature above 25   C  Adjust store air conditioning  avoid heat sources  nearby the cold unit and direct sunlight   Food not kept cold  enough  Too much air movement inside the   The unit should not be placed on places with  room  strong air circulation   Condenser coil blocked or dirty  Remove dust and debris   Evaporator coil iced up  De ice coil  manual defrosting or power off      Failure malfunction of the con   denser unit or other cooling Call authorized service personnel   components     Refrigerant level low  Call authorized service personnel   Defrosting does not start Start manual defrosting   Defrost cycle is not suitable  Call authorized service personnel   Inadequate ventilation inside the Leave adequate free space for the refrigerated  cabinet  air to circulate within the cabinet   Th tor      Pn eveperaior Toe Doors opened too long or too often    Keep all cabinet doors closed   Ambient temperature above 25  C   Adjust store air conditioning to maintain required  and relative humidity above 55 96  ambient conditions inside the room   Fans not operating  Call authorized service personnel        o6 Technical change
64. itet    Taste 2 AB Mit der AB Taste kann ein Alarm quittiert werden    Taste 3 LICHT Die Aus Ein Taste dient der internen Beleuchtung der K  hlvitrine    Taste 4 GET Wahrend die SET Taste gedr  ckt ist  wird der Sollwert angezeigt   Die SET Taste wird auBerdem zur Parametereinstellung ben  tigt    Taste 5 STANDBY Mit dieser Taste kann die K  hlung in den Standby Mode geschaltet    werden bzw  wieder eingeschaltet werden     6 3  Temperatureinstellung    Die Regelung der Innenraumtemperatur erfolgt   ber das Bedienteil der elektronischen Temperaturregelung   Diese ist unterhalb der K  hlvitrine leicht zug  nglich     Werkseitig ist die K  hlvitrine auf eine Temperatur von 4   C  Ausf  hrung  PRALINE   12   C  eingestellt  Die von    Ihnen gew  nschte Temperatur kann durch Halten der SET Taste  4  und gleichzeitigem Dr  cken der AUF Taste   1  f  r h  here Temperatur bzw  AB Taste  2  f  r niedrigere Temperatur eingestellt werden     Der Sollwert kann nur in bestimmten Grenzen verstellt werden  um eine Fehlbedienung zu vermeiden        10 Technische   nderungen vorbehalten G  ltig ab Oktober 2014         IDEAL   KE        Benutzerhandbuch    Nach einer Temperaturverstellung dauert es einige Zeit  bis die gew  nschte Temperatur erreicht wird  Pr  fen Sie  erst einige Stunden sp  ter die Temperatur im Innenraum mit einem genauen Thermometer und verstellen Sie das  Thermostat eventuell neu  Die Temperatureinstellung soll m  glichst bei der Installation durch den Fachh  ndler  erfo
65. ktionen verwendet werden  z B  f  r einen Verdichter  eine Abtaueinheit  als  Alarmrelais  usw   siehe Parameter U1 bis U4   Die zwei Widerstandsf  hler erfassen die K  hlraumtemperatur und    die Verdampfertemperatur  Die Vernetzung des Reglers erfolgt mit Hilfe einer ST Bus Schnittstelle     Allgemeine Angaben und Bedientasten    OO          CO    O    Taste T1  AUF   Durch Dr  cken dieser Taste wird der  Parameter oder Parameterwert vergr     Bert  Eine weitere Funktion der Taste  l  sst sich mit Hilfe des Parameters h     festlegen     Taste T2  AB   Durch Dr  cken dieser Taste wird der  Parameter oder Parameterwert verklei   nert  Eine weitere Funktion der Taste  l  sst sich mit Hilfe des Parameters bc  festlegen     Taste T3  Wahltaste  Die Funktion der Taste wird mit Hilfe  des Parameters h3 bestimmt     Taste T5  SET   Mit Dr  cken der SET Taste wird der  oollwert angezeigt  Die Funktion der  Taste wird mit Hilfe des Parameters  55 bestimmt  kann hier nicht ge  ndert  werden      Taste T6  STANDBY   Die Funktion der Taste wird mit Hilfe  des Parameters h amp  bestimmt  Sie ist als  Standby Taste voreingestellt  Das Ger  t  Kann so ein  oder ausgeschaltet werden   keine Netztrennung      Technische   nderungen vorbehalten    Die Bedienung des K  ltereglers erfolgt grunds  tzlich mit  den Tasten AUF und AB und SET  Die Standardanzeige zeigt  die Temperatur des K  hlraumes  Istwert Temperatur  an  Mit  der Bet  tigung der Taste SET schaltet die Anzeige auf die  vom Anwen
66. l  for beverages  offers various possibilities  of product presentation     The Brillant BAK series and Brillant L or SL come with flat base   there are no adjustable base decks      Interior of these units is designed to accomodate Euronorm trays   600x400mm   so these are the right units to display bakery pro   ducts like cakes  confectionary  sweets  e g     The ventilation openings inside the display cases must never be blocked     Valid from October 2014        User manual    Display cases with drawer element    Models BAK L and BAK SL  and series Green L and Green SL are equipped  with a drawer  which offers easy loading of the deck base from service side  with large products like cakes or similar                  Remove the drawer to clean evaporator and interior well  picture 1   Pull out  the drawer to the end position  then lift up the drawer approximately 5 cm to  remove the whole drawer element from the display case  picture 2   showing  the telescopic rails   After removing the drawer you have to take out the stain   less steel blind  picture 3   then lift up the evaporator coil and fix it in up position   picture 4   lock on left side of the handle   Now you have access to clean the  interior well and the evaporator coil     It is important to keep all display doors closed  If the doors are not fully closed  an even temperature  will not be maintained within the display case        Adjustable shelves    Your Brillant  respectively Smaragd display offers the poss
67. l system  or transmitted in any form or by any  means  electronic  mechanical  photocopying  recording or otherwise  without the prior written permission of AKE     Document  BH_Verkaufskuhl lsolierglasvitrinen_dt_en indd  Revision  14A  Valid from  October 2014    AKE reserves the right to change specifications and construction  as part of ongoing product improvement     42       Contents    Part A User manuel       Introduction 44  1 1  Welcome 44  1 2  Warranty and liabilities 44  1 9  Symbols and notes 45  1 4  Fundamental safety notes 45  1 5  Ongoing development 45  1 6  Validity 46  2  Purpose of use AT  di Proper use of the unit AT  4  Improper use of the unit 4T  D  Safety notes 47  6  Fundamental operating notes 48  6 1  Start up 48  6 2  Switch on the appliance 48  6 3  Setting the temperature 48  6 4  Automatic defrosting 49  6 5  Manual defrosting 49  6 6  Lighting 49  f  Loading restrictions 49  8  Operating description 50  8 1  Setting the temperature of the refrigerated base 82  8 2  Loading restrictions for the refrigerated base 52  9  Cleaning and care 53  9 1  General recommendations 53  9 2  Detergents 53  9 3  Special cleaning hints 54  9 3 1  Cleaning ot the interior and the evaporator o4  9 3 2  Glass cleaning instructions 05  9 3 3  Night blind cleaning instructions 55  10  Trouble shooting 56  11  Dangers 58  11 1  Electrical energy 58    11 2  Risk of injury    Part B Technical Information    1  Installation and start up instructions   help and advic
68. larm relay  etc   see parameters U1 U4   The two resistance sensors seize the refrigerating chamber  temperature and the evaporator temperature   Networking of the controller takes place via the ST Bus interface     General information    Oo o                Button T1  UP   By pressing this key the parameter or para   meter value is increased  A further function  of the key can be set with parameters 6 1     Button T2  DOWN   By pressing this key the parameter or para   meter value is decreased  A further function  of the key can be set with parameter    Button T3  Function key  The function of the key can be set with  parameter bJ     Button T5  SET   While SET key is pressed  the setpoint is  indicated  The function ofthe key can be set  with parameter 55  unchangeable in this  case      Button T6  STANDBY   The function of the key can be set with para   meter hh  It is preset as standby key    Thus the unit can be switched on or off  no  mains disconnection      Technical changes reserved    The cooling controller is generally controlled using the  buttons UP  DOWN and SET  The standard display indi   cates the temperature of the cold store  actual tempera   ture value   Press SET button to switch over the display  to the required cold store temperature  setpoint tempe   rature      The setpoint temperature can only be changed by  pressing buttons SET and UP or SET and DOWN at the  same time  While pressing the buttons  the changing  setpoint temperature is displayed  Afte
69. lgen    Je nach Umgebungstemperatur und Luftfeuchte darf die Innentemperatur nicht zu kalt eingestellt werden  dies    k  nnte an exponierten Stellen zu starker Eisbildung am K  hlelement f  hren  Dadurch wird die K  lteleistung beein  S  tr  chtigt und die kontinuierliche Abtauung  welche von Ihrem Fachh  ndler auf bestimmte Abtauintervalle einge     stellt wurde  verhindert  E  3  6 4  Abtau Automatik    Co  Die Abtauung erfolgt durch das elektronische Thermostat vollautomatisch  Toll  Werkseitig beginnt das Kuhlgerat in regelmaBigen Zeitabstanden  geschlossene Vitrinen alle drei Stunden   oelbstbedienungs Vitrinen alle zwei Stunden  abzutauen  Die Dauer einer Abtauphase betragt maximal A    30 Minuten  Wahrend dieser Zeit leuchtet auf dem Display links die mittlere LED  Nach erfolgter Abtauung startet  wieder automatisch der K  hlmodus     6 5  Manuelles Abtauen    Durch Dr  cken der AUF Taste  1  f  r drei Sekunden kann jederzeit eine Abtauung eingeleitet werden  Wahrend  einer Abtauung leuchtet die entsprechende LED  Die LED blinkt  wenn eine Abtauung angefordert ist  aber durch  operrbedingungen noch nicht gestartet werden darf     6 6  Beleuchtung    Die Beleuchtung der K  hlvitrine wird mit der Taste  3  am K  hlstellenregler aus  und eingeschaltet     7 Best  ckung der Vitrine mit Ware    Best  cken Sie die Vitrine   ber die Schiebe  bzw  Fl  gelt  ren von der Bedienseite mit vorgek  hlter Ware  Die  Produkte k  nnen auf den Glaszwischenborden und am Einlegeboden pla
70. lluminated  The LED flashes if defrosting is requested  but may not be started yet due  to interlock conditions     6 6     Lighting of the Display case is connected to the control unit and is then switched ON OFF by pressing the LIGHT  button  3  on the controller display     Lighting    7 Loading restrictions    Load the display case with pre chilled product from the rear doors  You can place the goods on the glass shelves  and on the base decks  BRILLANT models have a deep well with height adjustable base decks  The display case  is designed to maintain the temperature of pre chilled product     This refrigerated unit is not a refrigerator  and consequently  if warm product is introduced  there could be a con   siderable delay before the operating temperature falls to the normal operating level     Don t overload the cabinet with too much products  It is important to leave adequate free space for the refrigerated  air to circulate within the display case  Product should be kept clear of the shaded areas  shown in the picture  below  Consider the maximum load for shelves and base decks  shown on the next page      v  Correct Loading Wrong Loading                   Eo N   a  uu bt  D S k    ery PY TM E    3 Cold air curtain is not EA d 4 Air flow is blocked      N affected or blocked by     D P  and refused through  ee i goods   an V Y Y Y VY h too much goods   RA R  PPS A   Yt tt  ft N  unir ps cu pn end Optimum refrigeration tht ee DECKS   Ineffectiv   refrigeration  UR A 
71. ly attached     Each control unit consists of a control panel display and the PCB  power box  Both are built in a stainless steel box     The digital display is connected via a 2 m SUB D cable with the  PCB     This digital display can be removed and mounted separately up  to a maximum of 2 metres away from the PCB box  The required  cut out dimensions for the digital display are 87 5 x 56 5 mm       2 3  Information regarding power connection    These refrigerated units are delivered fully prepared for ready to use  The controllers are factory set for optimum  performance  After installation the Parameter H12  correction of the probe F1  must be controlled and if necessary  changed to the new conditions of the location   see also chapter CALIBRATION SENSOR  They should only be  adjusted by a qualified service engineer     Technical inforamtion       All fans are speed controlled by the programmable refrigeration controller STORK ST501  see also the referring  programming instruction     Some units are customized and delivered as requested without refrigeration controller  prepared for external  thermostats     Power supply  The refrigerated unit is provided with a 2 m long 3 wire power cord with plug and it may only be  connected to a power socket with a nominal voltage 230 V single phase 50 cycles  The metal construction of  the unis requires the use of a power socket with safety grounding at all times  The electrical power supply is to be  secured with a 16 ampere circuit 
72. n case it could have shifted during transport  only valid for slef  contained units      We recommend cleaning the equipment with a suitable disinfectant before first start up     The equipment must have reached the product manufactures indicated temperature before first filling  It is recom   mended to switch the new equipment on for a period of 24 hours before first filling     6 2  Switch on the appliance    The refrigerating unit is switched on and off by pressing  the STANDBY button  5  for approximately four seconds     Above the buttons there is a digital display of the cooling  regulator  This field shows the average temperature and  any errors     Before filling the display cases with food  please wait until  the desired temperature has been reached        Defrosting can be started any time by pressing the UP button for three    Button 1 UP  seconds  Button 2 DOWN The DOWN button can clear an alarm  Button 3 LIGHTING Button for intenall lighting  Button 4 SEI While SET button is pressed  the setpoint is indicated  Button 5 STANDBY With this button the controller is switched to standby mode  Pressing the    button a second time  restarts the unit     6 3  Setting the temperature    The interior temperature is regulated by an programmable digital refrigeration controller  This is located under   neath the refrigerated well and is easily accessible on operators side     The Display Cases are set to maintain  4  C  Model    PRALINE    for chocholate  12  C  as per factor
73. n speed                 p             Q    A         U  EVAPORATION OF CONDENSATE             7   S  Closed displays  only self contained     supplied with fully automatic evapo  iS  ration of condensate       Condensate tray removable for easy  N a o  cleaning    Remote refrigerated and self serve displays  ares  7 d Part    Connect to floor drain  Condensate pan  to empty manually  optional extras  E  Electrical evaporation tray  optional extras     EZ   EASY TO CLEAN       Lift up evaporator allows easy access for cleaning and service   tiltable front and cover glasses for cleaning       II   PROTECTION OF CONDENSER    Optional extra  Air filter protects the coil againts  dust  greasy air  damage and injuries  Easy cleaning in a dish washer       Technical changes reserved 59    Cold display cases    2  Installation and start up instruction    for authorized refrigeration companies and qualified service personnel    2 1  First steps    Control of delivery    Checkingfortransportdamageatthetimeofdeliveryisrecommended Anydamagesaretoberecordedandconfirmedin  writing atthe time of delivery and signified fromthe carrier  Forany damages arising after unpacking  you are obliged to  immediately communicate this in a written report and a telephone call to the supplier     Transport is covered under your responsibilities  Failing to report any transport damages with the currier within the  set time leads to the loss of responsibilities by the carrier     Installation    Don t tilt 
74. nd outside     Attention  Hold glass during opening and cleaning    Front glasses made of insulated double glass  Picture 3  are secured via a tight safety cord in end position   please support glass during opening and cleaning to save the cord    Don   t underestimate the weight of the glass  we recommend two persons for cleaning front and cover glasses  on larger display cases        9 3 3  Night blind cleaning instructions  The night blind of the display cases  for example  Gastro HCOE  should be cleaned with a moist cloth regulary   CAUTION     After all cleaning has been completed the display case has to be returned to its original state in  order to guarantee efficient operation        In addition to daily cleaning  service and maintenance of the display case is required to be carried out in regular  intervals by qualified specialists    See Part B   Service Notes     Valid from October 2014 Technical changes reserved 55    Cold display cases    10  Trouble shooting    It sometimes can have simple causes  if the unit is working incorrectly or it does not work for a longer time  This  could be removed independently  Before requesting service  please check the following     FAULT POSSIVLE CAUSE REMEDY    There is no power supply to    the unit  Check if plug is firmly in the socket     Check fuse   circuit breaker of the building     The cabinet does not  DOLOS Wace ine  Restore power to the cabinet     operate   Wrong setting of the programmable  controller  or digital d
75. netic valve 230V 50Hz HEATER    Valve x  AN   Heating FRAME external  by customer  LIGHTING  HEATER             not applicable  by KR   Brillant multidecks        L1 e                  PE e e       Valid from October 2014 Technical changes reserved 19    Cold display cases    6     Declaration of conformity    CE    Company    DECLARATION of CONFORMIT Y    Confirming the EC directives 2006 95 EG and 2004 108 EG    Ausseer Kalte und Edelstahltechnik GmbH  8984 Kainisch  Pichl 66  Austria    We herewith declare under our sole responsibility that the AKE product REFRIGERATED DISPLAY CASES    types designated as    Gastro O 53  O 70  O 87   Gastro G 53  G 70  G 87   Gastro G 53 KL  G 70 KL  G 87 KL  Gastro A G 53   BAK G 53  BAK G 70   BAK L  BAK KSL  Gastro KSV  HCO 70  HCO 87  HCG 87    Green A   Green G 54  G 71  G 88  Green  M1  O 53  O 70  Green L G 52  L G 69  Green KSL G 144  Green KSV G 144  BRILLANT KR    whichiscoveredbythisdeclaration meetsallsafetyand healthy provisionoftheECdirectives2006 95 EG  Low voltage  directive  and 2004 108 EG  Electromagnetic compatibility EMC directive   These directives represent legal bin   ding laws of the European Union for electrical equipments     To meet all safety and sanitation EC directives we fully comply with all applicable requirements of the following  international and national standards     14    EN 378 1  EN 378 2  EN12263  EN12284  EN 5008 1 1  EN5501 4 1  EN55014 1 A1  EN55014 2  EN55015  EN55022  EN60204 1  EN60335 1  EN
76. ning     Avoid the following detergents        Do not use acid  bleaching or chlorine cleaners    Never use high pressure  water pressure or steam jet cleaning machines    Do not use inflammable detergents    Never use sharp edged or metallic tools like steel wool or scrubbing cleanser for cleaning     Valid from October 2014 Technical changes reserved 53    Cold display cases    9 3  Special cleaning hints  9 3 1  Cleaning ot the interior and the evaporator    Take outthe GN containers or base decks  1  and air plenums  2  and inner tray from the well  First of all remove  visible dirt inside the well  bottom  to avoid a blockage of the drain  5 und 6   Open the cover from the evaporator  unit  3   Entire s s housing and evaporator coil can be rinsed safety and easily with a hand spray  4   Fans in low  voltage  24 V  allow danger free cleaning  Lift up the evaporator unit and move the lock to the left  5 und 6    now  the evaporator is fixed and allows easy access for cleaning corners and floor of the well  7         qu    ATTENTION  Before cleaning the unit with water please check that the water can run off  If the unit isn t plum   ped to a floor drain  place an external bin below the drain to collect the wastewater     The evaporator and the interior have to be cleaned with lukewarm soap water  Always dry the interior after  cleaning  After cleaning lift the evaporator  remove the lock and drop the evaporator back in its original position     Insert the inner tray  posit
77. nser unit  and no warm recycled air is drawn back into the condenser      For option 1  free flow in one line  we recommend to make a tunnel  wood or metal  to lead the hot air out of the  condenser unit  If the solution with air discharge on customer side is not possible  you can choose option 2  rear  ventilation  with air inlet and hot air discharge on same side  An additional fan can help to expel hot air out of the  counter     Distance between inlet and discharge openings  Variation 2  should be as wide as possible to avoid  re circulation of hot discharge air     Pleasetake carethatthe inlet   outlet openingsforthe air in and air discharge are wide enough andare NEVER blocked   No brake or obstruction of the air flow at any time  The condenser of a cooling system works as a heat exchanger  and has to transfer the thermal energy of food drinks and the electrical power consumption of the compressor to  the ambient air     Protection of the condenser  Air grills or a stainless steel filters protects the coil against dust  fatty air and damage     It further prevents injury as the condenser fins are very sharp     Air grills with small perforation or louvers with narrow blades can increase air resistance  So please  use appropriate air grills  Minimum size of air grills  twice of surface area of the condenser     Ventilation openings  air in and discharge  are never blocked   Refrigeration capacity will be reduced dramatically and the compressor could be destroyed        6
78. nt for possible damages  At the time  of installation please remove all internal base trays as well as glass shelves to prevent damage and to gain access  to the cooling well     Please ensure the counter and the countertop are perfectly level before installing the cabinet  The drain should be  at the lowest point of the well  Please test that the water can drain freely  If not expressed in the description  all  refrigerated units should have a connection to an external drain or at least a manual condensate tray  optional  or  an electrical condensate evaporation pan  optional      Each electrical installation work is only to be carried out by nominated specialists  Ensure that needed tools and  technical staff is available for the installation     Power supply  The units may only be connected to a power socket with a nominal voltage 230 V single phas 50  Cycles    Electrical Isolation  If a plug and socket is used to connect the cabinet  it must be accessible after the cabinet is  installed in its final position  If the cabinet is hard wired to the mains supply  without using a plug and socket  a  means of isolation must be provided     60 Technical changes reserved Valid from October 2014    7    IDEAL   KE        Technical information    2 2  Installation of the controller display    With self contained display cases the control unit is mounted underneath the ref  well  alongside the compressor  housing  With remote refrigerated display cases the control unit will be loose
79. nterhalb der Halterung nach vorne gezo   gen werden kann     Verstellen der Bordtrager  Die Bordtrager sind mit zwei Laschen in  den Ausnehmungen eingehangt  wobei die  obere Lasche Rasterungen f  r gerade und  schrage Positionen besitzt    Anheben des Tragers   Trager nach vorne herausziehen    Einhangen in der gew  nschten Hohe       schrage gerade Position auswahlen    Gultig ab Oktober 2014 Technische Anderungen vorbehalten 13    T       Benutzerhandbuch    Teil    K  hlvitrinen    Standvitrinen mit gek  hlten Unterboden    Die Standk  hlvitrinen der Modelle BAK KSL und Gastro KSV sowie GREEN KSL und GREEN KSV verf  gen   ber  einen gek  hlten Unterbau mit Umluftk  hlung f  r die Vorratshaltung  Je nach Ausstattung wird der Unterbau mit  T  ren und Zwischenborden  Standard  oder mit Ladenausz  gen  Option  f  r GN Schalen oder Flaschen geliefert     8 1   Temperatureinstellung K  hlunterbau    Die K  hleinheit wird durch Dr  cken des gr  nen Hauptschalters  ein  und ausgeschaltet  Neben dem Hauptschalter befindet sich  der K  hlstellenregler mit Digitalanzeige  Hier werden die lst   Temperatur und etwaige Fehlermeldungen angezeigt  Die werk   seitig eingestellte Temperatur betragt  5   C    Im unbef  llten Zustand kann es nach dem Einschalten des Gerates  bis zu drei Stunden dauern  bis diese Temperatur erreicht wird   Im bef  llten Zustand kann dieser Vorgang auf bis zu 24 Stunden  ausgedehnt werden  Diese Zeit wird weiters von den vorliegenden  Umgebungsverh  ltnissen b
80. older with built in electronic ballast and  bulb         Before replacing the lighting fixture  Free the screws from the lighting Unplug the lamp and take out the ligh   isolate the display case from the mains housing to loose the clips incl  lighting ting fixture with clips   or unplug it from the power socket  fixture  Do not drop the lighting fixture        Screw the clips into the lighting Plug in the new lighting fixture and Turn the power on and test that the  housing again  press it into the clips until it locks  lights operate  If normal operation  cannot be restord  call an electrician    Removing  hang out  sliding doors       Slide the left door in the     Liftthedooruntilitisreleased Tilt the sliding door and Repeat this process also  middle position  Now lift up from the small bracket disengage the door from the with the right door    the door so that you can feel  steering plate  on the instal  guide rail on top    some indentation  slide the lation frame    door easely to the left and   right side       For refitting the sliding doors Slide the doors back and Lift the door to suspend it Repeat this process also  first start with the right door forth so that you can hang into the small bracket  with the left door    and slide it into the guiding the door into the guiding   rail  On the picture you can rail    see the opening in the gui    ding rail for the roller of the   doors     66 Technical changes reserved Valid from October 2014    7    IDEAL   KE        T
81. on und Mechanik   Jede Anderung muss durch den Hersteller autorisiert werden        Neben den taglichen Reinigungsarbeiten ist in regelmaBigen Abstanden Service und Wartung der Kuhlgerate  durch qualifizierte Fachkrafte erforderlich  siehe Teil B   Wartungshinweise      G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 17    K  hlvitrinen    10  St  rungen und Ursachen    Falls das Ger  t fehlerhaft oder gar nicht arbeiten sollte  kann dies oft ganz einfache Ursachen haben  die eigenst  n   dig behoben werden k  nnen  Daher bitten wir Sie  folgende Punkte selbst zu   berpr  fen  bevor der Kundendienst  angefordert wird  um unn  tige  eventuell anfallende Kosten zu sparen     DEFEKT MOGLICHE URSACHE ABHILFE  Die Stromversorgung ist   berpr  fen Sie den Sitz des  unterbrochen  Schutzkontaktsteckers     Das Kuhlgerat    era eI keine Spannung an der Steckdose   Uberpr  fen Sie  ob die Sicherungen intakt sind     Die Elektronik ist falsch eingestellt    oder das Display bleibt dunkel  Servicetechniker kontaktieren    Eine oder mehrere T  ren sind ochlieBen Sie die T  ren und testen Sie die  ge  ffnet  Temperatur nach 30 Minuten erneut     Die Bel  ftungsschlitze in der    N N bedeck TAN ER Entfernen Sie jegliche Behinderung der    Luftzirkulation an den Bel  ftungsschlitzen     verstellt   zu viele oder zu warme Bringen Sie nur vorgek  hlte Ware ein und lassen  Lebensmittel Sie die Luft  ffnungen frei     Die Soll Temperatur ist zu hoch    Stellen Sie die gewunschte Temper
82. or of the control unit  EP Memory error  EPg Data loss at parameter memory    repair    ohould the options listed not be the cause of the error  please contact customer service        Valid from October 2014    The manufacturer is not liable for loss of goods  even if the appliance is still covered by warranty   It is recommended that the temperature of the appliance be checked periodically     Technical changes reserved 57    Cold display cases    1  Dangers  1 1  Electrical energy    Switch off the appliance immediately when there are interruptions in the electrical power supply     Any work carried out on the electrical units or utilities may only be carried out in accordance with electrical regula   tions by an electrician specialist or by those being instructed and supervised by an electrician specialist     CAUTION  ELECTRIC SHOCK HAZARD   Do not splash or pour water onto control panel or wiring        Appliances and unit components which are subjectto inspection  maintenance and repair work have to be completely  disconnected and volt free  First  check whether the activated parts have indeed been disconnected and are volt   free  then ground and short them out  Insulate any adjacent parts that are also energized      CAUTION  RISK OF INJURY   Be sure that the unit is disconnected and volt free before starting any inspection  maintenance or  repair work        11 2  Risk of injury  Some cooling appliances are equipped with gas springs  which keep the evaporator in the 
83. pe     Counter 7 b   facing i    Valid from October 2014    Air grill of the counter facing is more than 5 mm away  from the condenser coil           Air grill for cold  incoming air    Face of the con  E  Avoid wide gap    denser coil    cl between condenser     if  housing and counter  5 d A facing   emovabie   E    Close this gap with  Air grill       gt    wood or other air    tight material    Pull the condenser  unit up to the coun   ter facing    Counter             gt  gt  K  facing w    Technical changes reserved 63    7    AL   KE       Technical inforamtion    Part    Cold display cases    2 7  Air ventilation    All equipment is delivered with air in on service operator side and air discharge on customer side  The air flow is  throught the counter  from service side to the discharge opening on customer side    If there is no possibility to discharge the hot air on customer side  provide an opening either on left right side or on  the service side to place an air grill     Variantion 1  Variantion 2   Air flow directly through the condensing unit  and Air inlet and hot air discharge on the same side    thecounter  in straight line forward    rear ventilation           Si pum    PELL LALL LL LIL ILE LIL OL ELLE EL EL OL ELLE IL ELL OL ELE LOL EL EL OEE EL OLE LL OL EL ELS                        SANA ARAN                   RSS SRA RE RIN RAIN RAM EERUN TYN          Whichever option is chosen  please take care that only cold air from the room gets drawn into the conde
84. r changing the  setpoint temperature and releasing the buttons  the ac   tual temperature is displayed again  This is the standard  setting method     If you press the STANDBY button during operation  for  at least 3 seconds   the cooling controller is switched off  and the message LFF will be displayed  To switch on the  controller again  press the STANDBY button again     In addition to setting the temperature value  the buttons  UP and DOWN perform other functions  too  Pressing the  UP for 3 seconds will trigger a non standard defrosting  operation of the refrigerating plant  In the case of an  alarm  with buzzer triggered   the DOWN button can be  used for acknowledging the buzzer sound     Valid from October 2014    Technical information    Overview of the software features        These controllers are factory set for optimum performance   they should only be adjusted    If changes are required   by a qualified service engineer          OLO  3 Sek                              AJO  uS                    9 6    n Passwort    Display and setting the setpoint temperature    The standard display indicates the temperature of the cold store  actual  temperature value   Press SET button to switch over the display to the  required cold store temperature  setpoint temperature      The setpoint temperature can only be changed by pressing buttons SET  andUPorSETandDOWNAasatthesametime Whilepressingthe buttons  the  changing setpointtemperature is displayed  After changing the setpo
85. rden  Die Bel  ftungsschlitze an der  Vorder   1  und R  ckseite  3  des Ger  tes d  rfen auf keinen Fall bedeckt werden     Die K  hlung der pr  sentierten Waren erfolgt bei K  hlvitrinen mit    ap      W      Stapelgrenze Umluftk  hlung durch einen gerichteten Luftschleier aus gek  hl   Beladung Borde fe eu     EN N   max  50 Kg  p Dieser Luftschleier wird durch Ventilatoren bewegt  welche Luft  I hs eal aus dem Warenraum durch den Ruckluftkanal  1  ansaugen     R3     Die Luft gelangt unterhalb des Warenprasentationsbodens zum  pr Verdampfer  2  und durchstr  mt diesen  Gleichzeitig wird sie  3     D dabei abgek  hlt und   ber die Zuluft  ffnung  3  wieder in den   A if Warenraum geblasen     Z Die Luftf  hrung erfolgt   ber Luftleitbleche  durch die   2 po u EB  genaue Abstimmung der Komponenten wird eine sehr gleichm     E Bige Luftverteilung erzielt    Maximale Beladung    Zwischenborde je 50 kg  B  den gesamt 150 kg     Die Verkaufsk  hl  und Isolierglasmodelle werden mit h  henver   stellbaren Einlegeb  den ausgeliefert  Durch die tiefe K  hlwanne  ergeben sich viele M  glichkeiten der Prduktprasentation auf  verschiedenen H  hen  mit geraden oder schr  ggestellten  Einlegeb  den oder auch ohne Einlegeb  den z B  f  r Getranke        Nat  rlich k  nnen f  r diese Modelle auch Gastronorm Schalen  verwendet werden  GN 1 1 Schalen k  nnen direkt auf den  Einhangeleisten platziert werden  kleinere Schalen ben  tigen die                                                     
86. rfolgt an ein Wechselstromnetz mit einer Nennwechselspannung von 230 Volt und einer Frequenz von 50 Hz   Die elektrische Zuleitung ist mit 16 A  tr  ge  abzusichern     Der Elektroanschluss muss von einem Fachmann durchgef  hrt werden und den geltenden Normen   Vorschriften und Sicherheitsbestimmungen entsprechen        Der Anschluss an eine andere Spannung  Stromart oder Frequenz ist nicht zulassig     Gerate ohne eigene K  hleinheit d  rfen ausschlieBlich von einer Kaltefachfirma installiert werden        G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 293    K  hlvitrinen    2 4  Hinweise zum k  ltetechnischen Anschluss    Alle Vitrinen sind mit beschichteten Lamellenverdampfern ausger  stet  Die Anschlussrohre sind durch die  gesch  umte K  hlwanne nach unten gef  hrt  alle Rohrleitungen sind montiert und isoliert     Steckerfertige Vitrinen    Bei steckerfertigen Ger  ten sind die Rohleitungen fix mit dem K  lteaggregat verbunden  und der K  ltekreislauf mit K  ltemittel gef  llt  Vitrinen mit Expansionsventil verf  gen   ber  ein Schauglas mit Feuchte Indikator  zur Kontrolle im Servicefall   dieses befindet sich seit   lich am Kondensator     Zu Servicezwecken kann die K  ltemaschine samt Edelstahlgeh  use nach vorne heraus   gezogen werden  Es ist darauf zu achten  dass dahinterliegende Leitungen nicht   ber   dehnt werden oder einen Schaden erleiden        Zentralgek  hlte Vitrinen    Zentralgek  hlte Vitrinen sind f  r den bauseitigen Anschluss an eine Ver
87. s reserved Valid from October 2014    User manual    FAULT POSSIBLE CAUSE    The light is not switched on   The illuminating is    not working   The fluorescent lamp is defect     Too low temperatur in the cabinet     Condensation on the      Too high surrounding temperature  glasses     and too high humidity        Too high fan speed     Status display and error notification        7    AL   K E           REMEDY    Press the light button on the controller unit for  about one second  if the light does not work call    authorized service personnel        Change the fluorescent lamp  if the light does not    work call authorized service personnel       If you press and hold the SET   button you will    see the index value   this should not be below     4   C to 5   C by cabinets without insulated glass      25   C surrounding temperature and 55   air  humidity should not be exceeded  If it is possible       turn on the air conditioning        Call authorized service personnel    User manual    Part    REMEDY    Control sensor F1    Control sensor F1    Control sensor F2    Control sensor F2    Send the controller for  repair    Check all parameters    Send the controller for    MESSAGE CAUSE  T  Hefrigerating chamber temperature above alarm limits  parameter  A1      Hefrigerating chamber temperature below alarm limits  parameter  v A2   eL Sensor F1 error  short circuit  E IH Sensor F1 error  break  Fer Sensor F2 error  short circuit  ECH Sensor F2 error  break  EPL Intern err
88. sportschadens erlischt Ihr Anspruch auf Schadenersatz     Aufstellen    Ihr K  hlger  t soll rationell arbeiten  Stellen Sie deshalb die K  hlger  te nicht in die N  he einer Warmequelle bzw   an einen Ort  der durch starke Sonneneinstrahlung beeinflusst wird  Luftstr  mungen im Bereich des Kuhlgerates  durch unsachgem     installierte L  ftungen  Klimaanlagen oder Zugluft m  ssen ebenfalls vermieden werden  um  eine einwandfreie Funktion der K  hlm  bel zu gew  hrleisten     Meiden Sie stark Dampf erzeugende Ger  te in der N  he  Dies kann zu starker Vereisung des Verdampfers und  somit zu einer Leistungsminderung f  hren     W  hlen Sie f  r die Aufstellung einen Raum  der gut bel  ftet und staubarm ist  Die Funktion des K  hlger  tes ist  nur gegeben  wenn eine relative Luftfeuchte von max  60   und eine Raumtemperatur von 25   C nicht dauerhaft    berschritten werden     Eine korrekte Installation und st  rungsfreie Funktion ist Voraussetzung f  r die Inbetriebnahme des  K  hlm  bels  Die Installation muss mit den   rtlichen Elektro   Sicherheits  und Hygienevorschriften    bereinstimmen        Vorbereiten    Die Einbauk  hlvitrinen sind einfach und mit einem Minimum an Werkzeug zu installieren  Stellen Sie sicher  dass  M  belverkleidungen und Theken entsprechend der technischen Angaben vorbereitet sind  Wenn Sie das Ger  t  in den fertigen Unterbau installieren  sollten Sie die Oberfl  che w  hrend des Einbaus vor eventuellen Sch  den  sch  tzen     Es ist notwendig  da
89. ss der Unterbau waagrecht ausgerichtet ist  Der Abfluss muss der niedrigste Punkt in der  Innenwanne sein  Testen Sie  ob Wasser im Inneren der Wanne auch abflie  en kann     Alle Arbeiten  Installationen  Lieferungen und Leistungen d  rfen nur durch K  ltefachbetriebe und Fachpersonal  ausgef  hrt werden  Elektrische Installationen d  rfen nur von einem Fachmann durchgef  hrt werden  Sie m  ssen  sichergehen  dass geeignetes Personal und Werkzeug vorhanden ist  um Sch  den und Verletzungen zu vermeiden     Spannung  Alle Ger  te ben  tigen eine 230 Volt Spannungsversorgung  Alle offenen und zentralgek  hlten K  hlger  te  m  ssen aufgrund von Kondenswasser   ber einen externen Tauwasserablauf odereine Tauwasserschale verf  gen     M  glichkeit der Trennung vom Stromnetz  Wenn eine Steckerverbindung zum Netzanschluss verwendet wird  muss  die Steckdose leicht zug  nglich sein  um das Ger  t bei Bedarf  Reinigung  Wartungsarbeiten  vom Stromnetz zu  trennen  Wenn eine Direktverkabelung verwendet wird  muss eine M  glichkeit geschaffen werden  um das Ger  t  bei Bedarf vom Stromnetz zu trennen     22 Technische   nderungen vorbehalten G  ltig ab Oktober 2014         IDEAL   KE        Technische Information    2 2  Installation der Steuerkonsole    Die Steuerkonsole ist bei steckerfertigen K  hlger  ten unterhalb der K  hlwanne  seitlich neben der Kompressor   einheit befestigt  Bei zentralgek  hlten Ger  ten wird die Steuerung lose beigelegt     Jede Steuerung besteht aus dem B
90. stro G 53 KL  G 70 KL  G 87 KL  Gastro A G 53  BAK G 53  BAK G 70  BAK L  BAK KSL  Gastro KSV  HCO 70  HCO 87  HCG 87    Green A   Green G 54  G 71  G 88  Green  M1  0 53  O 70  Green L G 52  L G 69  Green KSL G 144  Green KSV G 144  BRILLANT KR    auf das sich diese Erkl  rung bezieht  den einschl  gigen grundlegenden Sicherheits  und Gesundheitsanforderungen  der EG Richtlinie 2006 95 EG  Niederspannungsrichtlinie   den Anforderungen der EG Richtlinie 2004 108 EG   elektromagnetische Vertr  glichkeit  sowie den Anforderungen der EG Richtlinie 97 23 EC  Druckgeraterichtlinie   entspricht     Zur sachgerechten Umsetzung der in den EG Richtlinien genannten Sicherheits  und Gesundheitsanforderungen  wurden folgende Normen und oder technische Spezifikationen herangezogen     36    EN 378 1 EN60529 EN61000 4 3  EN 378 2 EN60598 1 EN61000 4 4  EN12263 EN60598 2 1 EN61000 4 5  EN12284 EN60730 1 EN61000 4 6  EN 5008 1 1 EN60730 2 1 EN61000 4 11  EN5501 4 1 EN60730 2 9 EN61000 6 1  EN55014 1 A1 EN60947 EN61000 6 3  EN55014 2 EN60950 1 EN61058 1  EN55015 EN61000 3 2 EN61058 1 A1  EN55022 EN61000 3 3 EN61347 1  EN60204 1 EN6 1000 93 11 EN61347 2 3  EN60335 1 EN61000 4 2 EN61547  EN60335 2 EN61558  l4  4 fl  VA U  ft j    Andreas Pilz    Gesch  ftsf  hrer    Technische   nderungen vorbehalten    G  ltig ab Oktober 2014       WA         J  O   lt   S   lt   Q  3  a                                                                                                                             
91. svorschriften  insbesondere die VDE  und internationalen CEE Richtlinien  beachtet  Das Gerat wurde im Werk einer umfangreichen Endkontrolle unterzogen     G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 9    K  hlvitrinen    6  Allgemeine Bedienungshinweise  6 1  Erste Inbetriebnahme    Bevor Sie das Ger  t zum ersten Mal in Betrieb nehmen  sollten zwischen Aufstellen und Starten des K  hlm  bels  zirka 2 Stunden vergangen sein  Diese Ruhezeit wird ben  tigt  damit sich das in der Aggregatkapsel befindliche    l  welches sich beim Transport verlagert haben k  nnte  wieder zum Verdichter zur  cklaufen kann  gilt nur f  r  steckerfertige Ger  te     Das M  bel wurde nach der Herstellung im Betrieb vorgereinigt  Es ist jedoch zu empfehlen  das Ger  t mit einem  geeigneten Desinfektionsmittel  siehe Kapitel 9    Reinigung und Pflege    gr  ndlich zu reinigen  um eventuelle    berreste aus der Produktion oder entstandene Verunreinigungen durch die Aufstellung zu entfernen     6 2  K  hlm  bel einschalten    Die K  hleinheit wird durch Dr  cken der STANDBY Taste   5  f  r zirka 4 Sekunden ein  und ausgeschaltet       ber den Tasten befindet sich die Digitalanzeige des  K  hlstellenreglers  Hier werden die mittlere Temperatur  und etwaige Fehlermeldungen angezeigt     Bevor Sie die K  hlvitrine mit K  hlgut beschicken  warten  oie bis die gew  nschte Temperatur erreicht ist        Durch Dr  cken der AUF Taste f  r 3 Sekunden kann jederzeit eine    ese Der Abtauung eingele
92. t of refrigerant  security check of the unit    3 2  Spare parts    For spare parts please contact the responsible company for the display case  Spare parts could also be orde   red from specialized dealers in close vicinity to you     Name plates are on every of our products  They are placed on the underside of the electric controller box or  sidewise of the produkt  Please give this information of the name plate to your specialized dealer     Very important is the model name and the serial number or date of manufacturing     Sample  Model name  Gastro GE 80 53 E  Serial number  419001_EU331050_001  The serial number consists of  Confirmation Article  Quantity of units per order position    Valid from October 2014 Technical changes reserved 67    Cold display cases    4   4 1     Programmable digital refrigeration controller    Programming instruction     Refrigerated display cases    Control unit  Product and programming description       Product description    Suitable for all cooling applications  Defrosting mode free selectable   Air   electro   hot gas defrosting  Flexible fan circuit   Predefined parameters  USER Level     Themicroprocessor controlledcontrollerS 150 1 KUSKAR 112FPconsistsofaserviceandaseparatepowerpackplate  andisusedforthermostatictemperatureregulationinsimplerefrigerating plants  Itissuppliedwith230VACandhasfour  relay outputs as well as an exitforaDC voltage fan  The relays can be used for differentfunctions  e g  fora compressor   a defroster  an a
93. ten des Verdichters  eine elektrische Abtauheizung oder   ber Hei  gas   Eine elektrische Abtauung erfolgt immer nach einer Verdichterpause  die in d8 angegeben wird  Eine Hei  gas   abtauung erfolgt immer unmittelbar nach einer K  hlphase  Zus  tzlich kann   ber die Parameter d 1 und dB festge   legt werden  ob vor dem Abtauen der K  hlraum heruntergek  hlt werden soll     d3 Abtautemperatur  Ein Abtauvorgang wird beendet  wenn am Verdampfer die hier eingestellte Temperatur erreicht ist  Falls die  Abtauung zu lange dauert  wirkt die in dH eingestellte Zeitbegrenzung     FH L  fterdrehzahl im Regelbetrieb  Set1  otellgr  Be f  r die L  fterdrehzahl bei normalen Regelbetrieb und aktivem Set1     FH L  fterdrehzahl beim Abtauen  Set1  Stellgr    e f  r die L  fterdrehzahl beim Abtauen und aktivem Set1     Hic Kalibrierung F  hler F1 bis F4 Istwert Korrektur   Mit diesem Parameter ist es m  glich  Istwert Abweichungen zu korrigieren  die zum Beispiel durch F  hlertoleranzen   extrem lange F  hlerleitungen oder durch bauliche Schutzschaltungen  z B  Ex Barrieren  verursacht werden  Der  hier eingestellte Wert wird zum Messwert addiert     Hc   Istwert F  hler F1 bis F4  Der hier angezeigte Temperaturwert wird f  r die Regelung verwendet  Er berechnet sich durch   Regel Istwert    tats  chlicher Messwert   Gewichtungsfaktor    Istwert Korrektur    L1 Anzeige bei Standby  Mit diesem Parameter wird festgelegt  welche Anzeige im Display bei Standby erscheinen soll     Parameter der 
94. the refrigerated unit during the installation  the compressor unit could be damaged  only self contained  units   Completely remove the plastic film before start up  Take care that your counter frame will carry the weight  of the display case and fix the unit  It is essential that the countertop is perfectly level before the unit is mounted     The openings for air ventilation  air in and air discharge  are recommended the double size of the condenser sur   face  Please avoid placing the unit near any equipment which produce a lot of steam  i e  dishwasher  etc    as this  will cause icing of the evaporator   this will reduce performance of the unit     The display cases are designed to operate under normal ambient conditions of 25   C with up to 55   relative  humidity  Ideally the cases should be located so as to avoid excessive air movement from doors  air conditioned  vents  and other air sources or excessive heat from windows  sun  flood lamps and other heat sources     Correct installation is necessary for a trouble free start up of the refrigerated unit  Every installation  must conform to the local electric  safety and hygiene regulations        Preparation    The display cases are easy to install with a minimum of tools  All counter work needs to meet the technical speci   fication in terms of weight  cut out and support  All drop in units require installation level with the counter and we  recommend to protect the counter surface at the time of installation to preve
95. trisch Energie  Verletzungsgefahren    Teil B Technische Information    Ts  2   pag  p  2  2 4   2   2 6   2  2 8   2  3   3 1   3 2   4   4 1   o   6     Montage und Einbauanleitung   Hinweise   Montage und Einbauanleitung   f  r den Kaltefachhandler und Kaltetechniker  Erste Schritte   Installation der Steuerkonsole   Hinweise zum Elektroanschluss   Hinweise zum k  ltetechnischen Anschluss  Hinweise zur Abwasserinstallation   Vermeidung des gr    ten Fehlers bei der Installation  Be  und Entl  ftung   F  hlerabgleich   Instandhaltung   Wartung und Instandhaltung   Wartungshinweise   Bezug von Ersatzteilen   Elektronische Steuerung   Programmieranleitung   K  hlvitrine   Schaltpl  ne   Konformit  tserkl  rung          gt     OOO ON NN OD OD O    PO PO N  a  a a Ss SB   SB SB c So Oo Oo     os os os oo   OOOON nN OO DOTAAAABRYND       a ODOC Oo OO    21  22  22  23  23  24  24  25  26  27  21  28  29  29  30  30  33  36    a       K  hlvitrinen    1 Einleitung    1 1  Willkommen    Mit dem Kauf Ihrer neuen K  hlvitrine haben Sie sich f  r ein Produkt entschieden  das h  chste technische  Anspr  che mit praxisgerechtem Bedienungskomfort und attraktiver Warenpr  sentation verbindet     Um sicherzustellen  dass Sie den besten Nutzen aus Ihrer neuen K  hlvitrine ziehen  gilt es zwei Dinge zu beachten     Vor Inbetriebnahme des Ger  tes lesen Sie bitte ausf  hrlich die Empfehlungen und Anweisungen in diesem  Handbuch     Nehmen Sie sich die Zeit   Sie ist ihre Investition wert  Di
96. tschema  K  hlvitrine HCO KR     zentralgek  hlt  SUB D 9 pol  poe Nachtrollo   optional    5 pente    C9    e         IT    A     K  hlstellenregler   a9 ccs 7     WA YA M Y      ST501 KU3    1612214   RN EN N   Eu et NS ELEME    230V  230V  230V  230V    i  0 24V    JOS DO          EN 2 Q O        173   le   a A BR  66 BL          KO    ta      DRNA        i 22 14 d  Lodi    2 3 E PE L N HPE   N   PE N HPE L   Schl  sselschalter    Da an Ec e c poe od Blo  KUHL VITRINE       E    M3   L  fter Verdampfersatz ym ym     i  amp  IU    zm   L  fter Steuerung     bp   6p  A   Raumf  hler K  hlung tg    AGG AGG  BR ABL    i BL   ABL    P   Verdampferf  hler        Q    Beleuchtung K  hlung     VW    X   Magnetventil NETZ     gap cu   kaon       M3 230V 50Hz ANN C9 e d      X    AM    Heizung i   HEIZUNG      Ventil      RAHMEN   LICHT bauseits  i HEIZUNG      fess ee eye cal  entfallt bei KR   Brillant K  hlregal   LI s E  N e e    en i serine Se ie E duseuqueistatetutpeteiecteeduisus e ud tetes ce ese ixi editis teta    G  ltig ab Oktober 2014    Technische Anderungen vorbehalten    35    Technische Informationen    o    UJ    K  hlvitrinen    6  Konformitatserklarung    C C EG Konformitatserklarung    entsprechend der EG Richtlinie 2006 95 EG und 2004 108 EG    Die Firma Ausseer K  lte und Edelstahltechnik GmbH  8984 Kainisch  Pichl 66  Austria    erkl  rt in alleiniger Verantwortung  dass das Produkt K  hlvitrine    der Typen Gastro 0 53  0 70  O 87  Gastro G 53  G 70  G 87  Ga
97. tten Leuchtbalkens  und die Leuchtstoffrohre  wie folgt zu wechseln        Der Plastikschutz der Lampe Um das Leuchtmittel aus der Halterung zu bekommen Die neue Leuchtstoffr  hre  kann problemlos von der drehen Sie die Leuchtstoffr  hre  bis Sie die beiden einsetzen und festdrehen   Lampenfassung herunter  Kontakte der Leuchtstoffr  hre sehen  Die Leuchtstofflampe Danach den Plastikschutz  gezogen werden  vom Balken herausziehen  wieder befestigen     TEST  Stellen Sie die Stromverbindung wieder her und pr  fen Sie  ob die Beleuchtung funktioniert  Ist die  Fehlfunktion durch den Austausch der Leuchtmittel nicht zu beheben  wenden Sie sich an einen Elektriker oder  Servicetechniker     G  ltig ab Oktober 2014 Technische   nderungen vorbehalten 27    K  hlvitrinen    3  Wartung und Instandhaltung    Tausch des kompletten Leuchtbalkens    Beim Tausch des kompletten Leuchtbalkens  also Leuchtstoffhalterung inklusive Leuchtmittel  sollte wie folgt    vorgegangen werden            Bevor Sie die Lampenbalken tau   schen  trennen Sie die Vitrine vom  Stromnetz indem Sie den Netzstecker  ziehen        ochrauben Sie die Clips wieder auf  das Lampengeh  use     Wechseln von Schiebet  ren       Positionieren Sie die linke  ochiebet  re mittig und  heben Sie diese leicht an  bis durch leichtes Hin    und Herschieben kleine  Einbuchtungen bemerkbar  sind        Heben Sie nun die T  re an  bis sie unten aus den  F  hrungslaschen heraus   springt     Drehen Sie die Schrauben vom Lam   peng
98. turen   Verwendung von aggressiven oder   tzenden Reinigungsmitteln  Naturgewalt oder h  here Gewalt    Zudem von der Haftung ausgeschlossen sind   Glasbruch  Bruch von Kunststoffkomponenten  Dichtungen oder Beleuchtungsmittel    jegliche Sch  den  die nachweislich auf eine Fehljustierung der K  hlungssteuerung durch eine unqualifizierte  Person zur  ckzuf  hren sind    Sch  den oder Fehlfunktionen aufgrund eines fehlerhaften Zusammenbaus des K  hlm  bels nach dem Reini   gen    Bei Nichtbeachtung der angegebenen Hinweise kann der Garantieanspruch verfallen        6 Technische Anderungen vorbehalten G  ltig ab Oktober 2014    7    IDEAL   KE        Benutzerhandbuch    13  Symbole und Kennzeichen    Dieses Symbol deutet auf wichtige Hinweise f  r den korrekten Gebrauch des Gerates hin   Diesen Hinweisen keine Beachtung zu schenken  k  nnte zu Storungen am Gerat oder der Umgebung  f  hren        Dieses Symbol steht f  r eine m  gliche oder unmittelbare Gefahr f  r Leben und Gesundheit einer  Person und oder gefahrliche Situationen    Warnung vor gef  hrlicher elektrischer Spannung    Das Ignorieren dieser Hinweise k  nnte zu Sch  den an Ihrer Gesundheit und oder Besitz f  hren        Dieses Symbol steht f  r   Warnung vor heiBer Oberfl  che    Achtung  Verbrennungsgefahr   Ber  hren dieser Fl  chen  vor denen dieses Warnzeichen angebracht ist  ist verboten     Dieses Symbol deutet auf Hinweise f  r den Betrieb oder besonders hilfreiche Informationen hin   Diesen Hinweisen keine
99. tures adjustable in  range from  4   C to  12   C     This refrigerated equipment is not suitable for chilling foods  Any products to be presented have to be pre chilled  to the temperature required before being placed in the unit     Before loading the display cases with food or beverages  please wait until the desired temperature has been reached     Do not fill with hot foods and do not overfill        S   S    lt    S       S   he uni    3  Proper use of the unit ae  The drop in refrigerated displays conform to current state of the art technology  They are constructed in accordance A    with the recognized safety regulations and are reliable    However  health and or life threatening circumstances could arise for the user or a third party or damage could be  done to the appliance or other property or equipment should the unit be operated by non trained personnel in a  manner that is improper or in disregard of the regulations     The appliance may only be operated in a technically acceptable condition and in accordance with all regulations   safety regulations and with conscious regard of the operating instructions  Any other uses beyond those intended  are to be considered as not being in compliance with the regulations  The manufacturer supplier is not liable for  any damages resulting from such actions    The user bears the entire risk  Use in accordance with the regulations includes observance of the mounting and  operating instructions and keeping up with the inspect
100. tziert werden  Die Vitrine ist dazu ausge   legt die Temperatur der vorgek  hlten Ware zu bewahren     Dieses Kuhlmobel ist kein K  hlraum  Folglich kann das Best  cken mit zu warmer Ware dazu f  hren  dass es  erhebliche Zeit dauert  bis die Betriebstemperatur auf den normalen Wert sinkt       berladen Sie die Vitrine nicht mit zu vielen Produkten  Es ist wichtig  ausreichenden freien Platz f  r die Zirkulation  der Kaltluft zu bewahren  Der Kaltluftschleier  grau dargestellter Bereich  darf nicht durch Waren verstellt werden   Beachten Sie unbedingt die maximale Tragkraft der Zwischenborde und Einlegeb  den auf der n  chsten Seite         v  Richtige Best  ckung Falsche Best  ckung  3  Sue DIN      da  Der Kaltluftschleier der er A Der Kaltluftschleier der  Vitrine wird nicht von e   Vitrine wird durch die  Produkten beeintr  ch  AR ARR RRRA Produkte abgeblockt        tigt und unterbrochen        Aje m 7 Schlechte K  hlung und  Optimale K  hlung und JI   BODEN   J un  bersichtlichte Pr     Pr  sentation der Waren   l CENE E   sentation der Waren     G  ltig ab Oktober 2014 Technische Anderungen vorbehalten 11    K  hlvitrinen    8  Funktionsbeschreibung der K  hlvitrinen    Es ist wichtig ausreichend freien Platz f  r die Zirkulation der Kaltluft zu bewahren  Die grau dargestellten Bereiche  d  rfen nicht durch Waren verstellt werden  siehe auch eingezeichnete Stapelgrenze   Es sollte ein Mindestabstand  von 40 mm zur Beleuchtung und den Luftausblas  ffnungen eingehalten we
101. ungsfrei geschalten  werden        1 2  Verletzungsgefahren    Manche Kaltegerate sind mit Gasdruckfedern ausger  stet  welche den Verdampfer bei Reinigungs  oder  oervicearbeiten in der oberen Position halten  Wenn die Gasdruckfedern nachlassen und den Verdampfer nicht  mehr sicher in Position halten  sind diese unverz  glich von einem Servicebeauftragten zu erneuern     Eine weitere Gefahrenquelle stellt der unsachgem    er Umgang mit den Gl  sern der Vitrine dar     ACHTUNG VERLETZUNGSGEFAHR DURCH GLASBRUCH   ocheiben immer mit beiden Handen in die jeweilige Endposition bringen        20 Technische Anderungen vorbehalten Gultig ab Oktober 2014    Technische Information    7     1     STEUERUNG      amp    EINFACHE MONTAGE    Drop in   Der umlaufende Einh  ngerand  erm  glicht die Montage von oben  in den Thekenausschnitt     Slide in   F  r schwere Ger  te  empfiehlt sich der Einschub  mit dem optional erh  ltlichen  FuBgestell                 V     v              F    e h  henverstellbar          BE  UND ENTL  FTUNG f    optimale Be  und Entl  ftung des K  lteaggregates    ffnungen  die um 50 Prozent gr    er sind als die  Kondensatorfl  che    Standard   Bel  ftung von der Bedienerseite  und Entl  ftung an der  Kundenseite                   Sonderbau  Be  und Entl  ftung an der Bedienerseite    Il   KONDENSATORSCHUTZ    Die Be  und Entl  ftung an der Bedienerseite ist nur mit  optional erhaltlichem FuBgestell oder breitem  Maschinenfach moglich        Vor Bestellung beru
102. upright position during  cleaning and service  Once the gas springs begin to weaken and are not able to keep the evaporator in the upright    position anymore  they are to be removed and replaced immediately by a specialized service representative     Be carfully by cleaning and handling the glass  Improper use can cause breackage of glass      CAUTION  RISK OF INJURY DUE BREAKAGE OF GLASS   Hold the glass with both hands until reaching the end position        58 Technical changes reserved Valid from October 2014    Technical information       1 Installation and start up instructions    help and advice    EASY TO INSTALL    Drop in   Surrounding mounting flange   drop in from above into the  cut out of the counter top    Slide in   Install heavy cabinets by using  optional base unit to slide into  the counter                2   AIR CIRCULATION  Optimum air circulation for condensing unit  Provide front  and rear openings twice the surface area of the condenser for  adequate air circulation    Standard  Air in on service side and air dis   charge on customer side                On demand  Ventilation on service side       Air inlet and discarge on service side is only possible with our  optional available base unit         Choose the configuration that      suits your servery layout  best   before your order     Valid from October 2014       2    CONTROL UNIT    Display detachable for  installation in cladding  Water resistant display  Continuous regulation of air  flow via fa
103. vermischt und wieder angesaugt wird        Alle steckerfertigen Vitrinen verf  gen   ber ein ausziehbares Kompressorgehause  Damit haben Sie die M  glichkeit  den Kondensator am L  ftungsgitter des Lufteinlasses zu positionieren und Luftzirkulationen zu verhindern     Die Luft  ffnung der Verkleidung ist weniger als 5 mm  vom Kondensator entfernt     Die Luft  ffnung der Verkleidung ist mehr als 5 mm  vom Kondensator entfernt          ufteinlass  f  r Kaltluft    Frontseite des  Kondensator   geh  uses    entfernbares    Luftergitter        Theken  PB    verkleidung    G  ltig ab Oktober 2014           Ausblas  ffnung   is fur Warmluft    Lufteinlass  fur Kaltluft    o gt  l          Frontseite des    Kondensator  le   schmaler Spalt Gehauses d     zwischen dem      Kondensator  entfernbares f  Geh  use und L  ftergitter      Verkleidung  i  Verschlie  en Sie Theken  1  diesen Spalt mit    verkleidung    einem Dichtband     Technische Anderungen vorbehalten           mu az   Ausblas  ffnu ng   u  f  r Warmluft  11     gt     Vermeiden des  Spaltes zwischen dem  I Kondensatorgeh  use  TA und Verkleidung   TE ochlieBen Sie  diesenSpalt mit    einem Tunnel aus   Holz oder Blech  Ziehen Sie die    Verfl  ssigereinheit bis   zur Verkleidung vor        Lu LL a S    25    Technische Informationen    Teil    K  hlvitrinen    2 4 Be  und Entl  ftung    Standardm    ig werden die Ger  te mit Bel  ftung an der Bedienerseite und Abluft an der Kundenseite ausgeliefert   Die Be  und Entl  
104. ves  filter dryers and eventually Evaporator Pressure Regulators must be supplied  and installed by others  Evaporation temperature must be kept constantly to the require value   see also rating  plate of the unit     Installation work    All installation and servicing work must be made by qualified refrigeration personnel only  The installation must  comply with the state of art  the local electrical   health  and safety regulations and directives    The whole installation is to take into operation and a function and safety test must be performed  A written report  of these tests must be given to the owner     2 5  Information regarding water and drain connection    There are different ways to dispose condensate   Closed cabinets  for assisted service    self contained    oelf contained displays for assited service  entirely closed with glass on front top sides and doors on operator  side  come with integrated evaporation of the condensate     Displays for assited service  remote refrigerated  and all self serve displays  All these units are equipped with siphons  trap   so plumb connections or connections to external condensate    evaporation pans must be made in compliance with all Federal  State and Local plumbing Codes and Ordinances   Ensure that condensate and wastewater can not reflux into the refrigerated well     All drain plumbing installations must be performed by a qualified plumber   in compliance with DIN  1988 for water and DIN 1986 for wastewater        62 Te
105. wandfreiem Zustand sowie bestimmungsgeg      sicherheits  und gefahren   bewusst unter Beachtung der Betriebsanleitung benutzt werden  Eine andere oder dar  ber hinausgehende  Benutzung gilt als nichtbestimmungsgem      F  r hieraus resultierende Sch  den haftet der Hersteller Lieferant  nicht  Das Risiko tragt alleine der Anwender     Zur bestimmungsgem    en Verwendung geh  ren auch das Beachten der Einbau  und Betriebsanleitung sowie die  Einhaltung der Inspektions  und Wartungsbedingungen    Nach Reinigung muss das Gerat auf lockere Verbindungen  Scherstellen und Besch  digungen untersucht  werden  Festgestellte M  ngel sofort beheben  Das Ger  t nicht f  r betriebsfremde Zwecke nutzen  Anderungen  am Ger  t sind nur durch den Hersteller zul  ssig    Beim Nachf  llen von K  ltemittel darf nur das auf dem Kennzeichnungsschild angegebene K  ltemittel verwendet  werden  Das Nachf  llen darf nur vom autorisierten Kundendienst durchgef  hrt werden     4  Nicht bestimmungsgem    e Verwendung    Die Kuhlvitrinen sind nicht geeignet  um Lebensmittel herunterzuk  hlen  Die K  hlger  te d  rfen nicht mit  Lebensmitteln bef  llt werden  welche eine h  here Temperatur aufweisen als die daf  r vorgeschriebene  Ein  Betrieb mit einer niedrigeren Temperatur als  2   C ist nicht betriebssicher m  glich     Die L  ftungsschlitze im vorderen und hinteren Bereich der Warenauslageflache d  rfen nicht zugestellt werden     5   Sicherheitsrichtlinien    Bei der Fertigung wurden alle Sicherheit
106. y setting  Your    desired temperature can be set by holding down the SET button  4  and simultaneously pressing UP button  1  for  higher temperatures or DOWN button  2  for lower temperatures     The desired value can only be set within a certain range in order to prevent any operating errors        48 Technical changes reserved Valid from October 2014               User manual    After resetting the temperature some time needs to pass before the desired temperature has been achieved   Please check the interior temperature a few hours afterwards with an exact thermometer and reset the thermostat  if needed     Depending on the surrounding temperature and humidity  the interior temperature is not to be set too low as this  could lead to icing on exposed areas of the cooling element  This will interfere with the cooling performance and  with the continuous defrosting which has been set by your specialized dealer for a certain interval     6 4  Automatic defrosting    Automatic defrosting takes place via the electronic thermostat and is fully automatically controlled    The defrosting process takes maximum 30 minutes  Defrost cycles are pre programmed and starts every 3 hours   self serve displays  or 2 hours  displays for assited service   Cooling mode starts automatically after the end of  defrost mode     6 5  Manual defrosting  Defrosting can be started any time by pressing the UP   button  1  for three seconds  During the process of defros     ting the respective LED is i
107. y shows  4   C   increase actual value correction by  3        Sample  Average temperature measured inside the cabinet is   3   C  the digital display shows  5   C   decrease actual value correction by  2     ATTENTION  Do not measure temperature during defrost mode    air temperature will raise up  but product temperature remains unaffected     2 9  Maintenance    How to change the fluorescent light tube    Space inside the stainless steel lights housing is limited   so we recomment to remove the whole lighting fixture   for replacing the fluorescent tube  standard T5 lamps    see also  Replacment of the lighting fixture on next page    Caution  DO NOT service the lights  without isolating the cabinet at the main switch or unplugging it  from the power socket        Remove the plastic diffu  Spin the fluorescent tube to see the electrical contacts  Re fit the plastic diffusor  sor from the lighting fix  pull away the contacts from each end of the sockets and install the ligthing fix   ture to access the fluore  to release it  Insert the new tube and fix it correctely  ture inside the s s lamp  scent tube  housing     TEST  Turn the power on and test that the lights operate  If normal operation cannot be restord  by changing the  tube  call an electrician     Valid from October 2014 Technical changes reserved 65    Cold display cases    3  Maintenance and Service    Replacment of the lighting fixture    Instruction for replacing a complete fluorescent lighting fixture  lamp h
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Ar Condicionado Unidade Tipo Cassete Ar  - UKDentistry  SYSTEXX ComforT V22  MLM990H User Manual  PROBLÈME CAUSE PROBABLE SOLUTION Accumulation (Piling)      Bedienungsanweisung PizzaGrill FourFour Mode d  Arabesk 6 User manual  Programs>2Know! Toolbar - Renaissance Learning Center    Copyright © All rights reserved. 
   Failed to retrieve file