Home
Samsung AHT18A1MEA User Manual
Contents
1. OWNER S INSTRUCTIONS AHT24MME AHT24A1MEB AHT24MMB AHT24A1MBA AHTISMME AHT18A1MEA AHT20MMB AHT20A1MBA WINDOW TYPE ROOM AIR CONDITIONER Cool and Heat mu w IN Li Y K DB68 00401A 8 E 2 Safety Precautions The following safety precautions must be taken when installing and using your air conditioner 1 The air conditioner must be plugged into its own specific power source which must be installed in compliance with national wiring earthing and safety regulations Depending on national regulations and your specific installation you may need to install A circuit breaker For further information on electrical requirements contact a professional electrician This device must be installed according to the national electrical rules 2 Make sure that the unit is correctly ventilated at all times do NOT place clothing or other materials over it 3 NEVER spill liquid of any kind into the unit Should this happen unplug the unit and contact your installation specialist 4 Do NOT insert anything between the air outlet blades as the inner fan may be damaged and you may be hurt Keep children away from the unit 5 ALWAYS ensure that the power cable is in good condition Make sure that it is not walked on or damaged by items placed on or against it If the power cord is damaged in any way it must be replaced by an approved power cord available from the manufacturer or its ser
2. illustrations in the step by step procedures use four different symbols a gt PUSH IMPORTANT NOTE E 5 Heating Your Room You must select the HEAT mode if you wish to higher the temperature in your room You can also set the fan speed 1 Select the operating mode and fan speed To Heat your room Set the operating mode dare g gisa with a selection dial to ae Z N l High fan speed HI HEAT wits E ee Low fan speed LOW HEAT fener NGA Result 9 The air conditioner starts up in Heat mode vv wy Pia lial ee The fan starts up at the speed selected OPERATION gt Youcan change modes at any time 2 To adjust the temperature turn the temperature control dial 2TC 23 C to the red position Left side The air conditioner is started heating if room temperautre is lower than selected temperature Result slajl iay obia THERMOSTAT 3 To control the direction of the air flow refer to page 9 E 6 Cooling Your Room You must select the Cool mode if you wish to lower the temperature in your room You can also set the fan speed 1 Select the operating mode and fan speed To cool your room Set the operating mode with a selection dial to High fan speed HI COOL Low fan speed LOW COOL Result 4 The air conditioner starts up in Cool mode The fan starts up at the speed selected gt You can change modes at any time 2 To adjust the temperature turn the temperature co
3. 09 0o9o090 090o9o090 09 0o9o 200090959060 006 0959050009050 00909590 0000050050 00005000000 Note If the wall is greater than 150mm thick cut the wall back on a 45 angle if possible O 99 45 45 QOO o9 oo OO oO OO a gt OOO o oco 25 o ooo 0000 T Q rd OOS Soo 000060 oO 9099 209 So 0255 CEOS o Oo oe 9 oQ o Oo ooo O Nama 100mm or more wall so or other o Obstacle E 13 Method of Installation T Rubber cap Screw Drain Hose Bottom Side View with Drain Pan and Hose in Place E 14 Installation of the Drain Tube Fix the drain tube as shown in the figure Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner Example High storage 1 Open the front grille 2 Remove the front panel 2 1 Press both sides of the cabinet in the direction of the arrow as shown in the figure 2 2 Pull the lower part of the front panel slightly forward below three inches 2 3 Lift the front panel upward Ca Applying excessive force to remove the front panel may cause damage to the tab be sure not to use excessive force 3 Remove two screws on the lower right and left sides of the unit 4 Remove the chassis from the cabinet 5 Remove the rubber cap in
4. e blades Drip from the blades NG W E 9 Operating Recommendation Here are a few recommendations that you should follow when using your air conditioner Topic Recommendation Warm air The air conditioner circulates warm air to heat your room circulation as a result some time will be required after starting the air conditioner to warm the entire room If necessary set the air conditioner going a short time before you wish to use the room Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again automatically Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used Mode Outdoor Indoor Indoor Humidity Temperature Temperature Heating 0 C to 21 C approx 28 C or less Cooling 210 to 54 C approx 21 C to 32 C approx 80 or less If the air conditioner is used at Then Higher temperature The automatic protection feature may be triggered and the air conditioner stopped Lower temperature A water leakage or some other malfunction may happen if the heat exchanger freezes Higher humidity levels Water may condense on and drip from the surface of the unit if itis used for long periods Cleaning Your Air Conditioner To get the best possible use out of your air condition
5. er you must clean it regularly by two weeks to remove the dust on the air filter Ca Before cleaning your air conditioner ensure that it is switched off and unplugged from the wall socket 1 Open the front grille by pulling on the tabs of the unit gt gt The removal of the front grille makes it easier to clean the air conditioner After opening the front grille lift up as much as possible and pull down to release them and vice versa Front grille 2 Grasp the handle on the air filter and lift it slightly and then out to the front ge EO Front grille 3 Remove all dust on the air filter with a vacuum cleaner or brush Grille groove Body guide 4 When you have finished slide the air filter back into position 5 Clean the outer surfaces with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Wipe them dry with a clean soft cloth gt Ifyou Then Will not be using the Set the fan going for three to four hours air conditioner for a to dry the inside of the air conditioner long period of time thoroughly 4 Switch the air conditioner off and unplug it from the wall socket Clean the filter and outer surfaces Have not used the air Set the fan going for three to four hours conditioner for a long to dry the inside of the air conditioner period of time thoroughly E 11 E 12 Solving Common Problems Before contacting the after sales service perform the
6. following simple checks They may save you the time and expense of an unnecessary call PROBLEM EXPLANATION SOLUTION The air conditioner does not operate at all Check that the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct operating mode has been selected COOL HEAT or FAN The air conditioner does not cool Check that the correct operating mode has been selected The room temperature may be too low or too high Dust may be blocking the air filter refer to page 11 for cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit The air flow direction does not change when you set the air flow blade swing switch to the ON position Check that the air conditioner has been switched on if necessary turn the operating mode selection dial Odours are permeated in the room during air conditioning Air the room Technical Specifications Design and specifications are subject to change without notice Model Power Supply AHT24A1ME AHT24A1MEB AHT18A1ME AHT18A1MEA 220 240V 50Hz AHT24A1MB AHT24A1MBA AHT20A1MB AHT20A1MBA 220V 60Hz Method of Installation Before installation be sure to check the installation area for the air conditioner and installation method of
7. ing to the model oO ni A Inner air flow blades Air outlet right left orientation Outer air flow blades up down orientation Air inlet Outside Air inlet Inside Air filter The air filter is located in inside Operating mode selection dial N t E LOW HEATV VY bw coo OPERATION algal jga LOOM o Ventilation lever NG Power Cable 3 Power cable connec tion should be committed to an installation engineer BLUE BROWN YELLOW GREEN ki Main Power Earth Cooling lamp Temperature control dial dylai anya e za THERMOSTAT Air flow blade swing switch EA Getting Started You have just purchased a window type room air conditioner and it has been installed by your installation specialist Your Owner s Instructions contain much valuable information on using your air conditioner Please take the time to read them as they will help you take full advantage of the unit s features The booklet is organized as follows The illustration on page 4 shows the air conditioning unit it indicates the location and purpose of the main parts and controls on the unit In the main part of the document you will find a series of step by step procedures for each function available The
8. ntrol dial to the blue position Right side Result The air conditioner is started cooling as turn on the cooling lamp if room temperature is higher than selected temperature 3 To control the direction of the air flow refer to page 9 isa daana A w ni LOW HEATV Ow cooL OPERATION 27 C 23 C 29C 27C PA ell dan rs THERMOSTAT E 7 Airing Your Room lil OFF If the atmosphere in your room is stale you can air it using the Fan feature and if necessary evacuate the stale air outside 1 If you wish to evacuate stale air outside push the ventilation lever on the front of the unit to the right and the open position Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the closed position Result The air simply circulates inside the room Set the operating mode selection dial to the FAN position Result lt The air conditioner starts up in Fan mode Note The left right S FAN have it s same function To control the direction of the air flow refer to page 9 Switching the Air Conditioner Off e diera Q giga FAN JD TD FAN pr wa MT viz HI HEAT 9 35 Hi CooL ze jen LOW HEATY VY Sw coo OPERATION alal OFF t ipa Q Q idea FAN JD UD FAN p S v HI HEAT 3 iii coo iiss J Ead LOW HEATY v DW cool OPERATION E 8 You can switch the air c
9. onditioner off whenever you want 1 To switch the unit off simply set the operating mode selection dial to the OFF position Result The air conditioner stops operating Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the right hand side of the unit thus increasing the efficiency of the air conditioner 1 Setthe air flow blade swing switch to the ON position Result The inner blades swing automatically left and right iil Jal OFF ON 2 To stop the blades moving left and right set the air flow blade swing switch to the OFF position gt To stop the blades in a specific position and orient the air flow in the Zu tun corresponding direction simply set the switch to the OFF position OFF ON when the blades are in the desired position Adjusting the Air Flow Direction Vertically Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Adjust the blades to face Cooling Upwards Adjust the air flow blades to the desired position by pushing them upwards or downwards Y NN SW o gt gt If you orient the air flow blades downwards and the unit operates in Cool mode for long periods of time dew may Form on the surface of th
10. serted into the basepan 6 Fixthe drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original condition x When assembling the front panel be sure to fix with a supplied screw TH 2S 4X10 In the case of an area where the drain pan can be directly installed on the rear side of the unit after installing the air conditioner 1 Follow steps 5 and 6 only THIS AIR CONDITIONER IS MANUFACTURED BY Samsung ELECTRONICS Printed in Korea
11. the drain hose Checkpoints prior to installation 1 Check the cabinet and front grille of the unit for any harmful defects Such as scratches 2 Be sure to check the power supply Refer to the specifications on the label attached to the unit Installation Conditions 1 Asthe unit is heavy the wall or window of the installation area should have sufficient strength and durability for operation of the air conditioner and for prevention of any vibration or noise If itis weak reinforcement work should be performed separately 2 Itis advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operating the air conditioner in closed areas such as inner building with cooling operation and result in trouble with the unit See the illustration below Awning o Fence 09 20 oO 6 00000 150mm min Oo 0 oO O c o 90o09o090 090o90090 090o9o0 0990090
12. vice agent 6 Do NOT attempt to repair the unit yourself If it is damaged in any way contact An approved service center The outlet at which the air conditioner was purchased 7 Do NOT place any obstacles in front of the unit Contents PREPARING YOUR AIR CONDITIONER Safety Precautions sasa oe e ee e edes 2 Air Conditioning Unit Main Parts and Control Panel sssss 4 Getting Started e et e e EE ee 5 OPERATING YOUR AIR CONDITIONER Heating Your Room inet tee en esieti nus 6 Cooling Your ROOM aree eon iet ete a 7 Airing YOUr ROOM i e sie it red ide a Na o a iy 8 Switching the Air Conditioner Off eecceeceeeeeeeeeeeeeeeeeeseeeeeneeseeeeeireseaeeeneetee 8 Adjusting the Air Flow Direction Horizontally eeeeeeee 9 Adjusting the Air Flow Direction Vertically seeeenn 9 RECOMMENDATIONS FOR USE m Operating Recommendation sssssesseseeeeeneeeeneee nennen 10 m Temperature and Humidity Ranges seeeemee 10 m Cleaning Your Air Conditioner sse 11 m Solving Common Problems essen nennen 12 m Technical Specifications aseena a ga aa pa a AN E 12 METHOD OF INSTALLATION 6r0n0en en nene anan n anana e nawan a nane nana anane nn stes nnne 13 ES Air Conditioning Unit Main Parts and Control Panel 3 amp The design and shape are subject to change accord
Download Pdf Manuals
Related Search
Related Contents
Untitled - Fichier PDF PYLE Audio PLDMN65 User's Manual VELUX ZZZ 234 M08 Installation Guide Descuelgue el auricular. Main key user manual 取扱説明書を必ずご参照ください 1/3 ZTL1392 改訂:**2013 年 11 月 LITEMAX DLF/DLH1268 Sunlight Readable 12.1” LED B Garmin Mobile XT Owner`s Manual Mode d`emploi - Site Ressources des Ceméa Pays de Loire FT Dermogenol Copyright © All rights reserved.