1.    Events will be saved in two column format  with coordinates as displayed  on the graph  This is useful if someone wants to save the events in terms of mass vs  energy in  the particular case of ERD TOF  This will involve the    reshape    feature discussed in section 3 1   Similarly  the vertices coordinates of a polygon can be saved by right clicking on its legend entry and    selecting    Save        2 5 Projections    Energy projection is done by selecting    Projections  gt  Energy projection   by typing CTRL E or by  clicking the  amp  icon  Then  for each events included in a polygon  its energy is calculated according to  the formula    E      established by the user in the Channel Selector dialog  The computed energy value  for each event is divided by the division factor and accumulated in a spectrum of length    spectrum  size   This spectrum will appear in the  Mass separated energy spectra  window  one spectrum for  each displayed polygon    If the user has entered parameters for  Spectrum directly from channel  in the dialog  he will be  asked to indicate to which element this spectrum corresponds by clicking on a periodic table    In order to estimate material stability under irradiation or the beam induced desorption  the user  can select    Projections  gt  Count rate progression  from the menu  The program will divide the event    list in  spectrum size  intervals  and sum the events within each displayed polygon for each interval     Energy projection usi
2.  between latin and greek characters is shown in    Table 1  These subscript superscript greek symbols can be shelled one in each other  For example     E    a _ i_ 0    will produce E   Note that braces are always required     Table 1  Equivalence between latin and greek characters                       a b c de f g h i jk   m n o p q r s t u v w x y z  a Dx 6     d y m i1   9 k    u vo nr 0 p oo T U  amp        oy  A B CD FGH IJ KLM NOP QRS TU VW XK Y Z  A B X A    r HIVJ K A MN OT   O PXYTY    Q2  amp  T Z          9 Data set operations    Different operations can be performed on data sets  The following operations are selected by right     clicking on the name of a data set in the legend of either the    events graph  or in the    mass separated    energy spectra  windows       Save Saves a data set in a two column file with x and y coordinates as displayed on the screen     Copy Creates a duplicate of a data set     Delete Deletes a data set     Edit Allows to change polygon or curve color  line type  legend  etc     Sort Sorts the points in ascending order     16      Swap Swaps the x and y coordinates       Operation Numerical operations can be performed on data sets  These are accessed by right   clicking on a data set and selecting    Operation     They can be performed on the whole data set  or on a region of the data set  defined by pressing the CTRL key and dragging over the region   Many regions  defined by    markers   can be defined at the same time  The markers
3.  can be  cleared by right clicking and selecting  Clear markers   There are two operation types         With a constant Take a data set and either add  subtract  divide by  or multiply by a  constant  The constant is entered in the  constant  input field and the operation can be  performed on x  y  or both axis  Can also be performed by selecting a data set and directly    typing the desired operation          x             With a data set Same as operation with a constant but with another data set instead of a  constant  These operations can be performed by typing CTRL and the desired operation           X      The operation will be performed only in the x axis region where both data  sets are defined  and will interpolate linearly between the points of the selected data set if    both data sets are not on the same x scale       Fit Data sets can be fitted either by a box car average  a polynomial or a bicubic spline fit  These  are accessed by right clicking on a data set and selecting    Fit     Like numerical operations  they  can be performed either on the whole data set or on regions defined by markers  The  order   parameter represents the number of points over which the average is done for box car average   the order of the polynomial for polynomial fit  or the number of bicubic splines for spline  If  markers were defined  only data within greyed regions will be considered  In this case  the  option is given to interpolate between region markers or to extrapolate to 
4.  right clicking on the data  set legend entry and selecting    Save     If modified data are not saved  they will be cleared later in the    process  and modifications will be lost     5 Setting experimental parameters    Inorderto tell Allegria which spectrum to convert and other experimental conditions  the Experimental  Parameters dialog can be accessed by typing CTRL E  by selecting the    Conversion  gt  Experimental  parameters  menu or by clicking the 44 icon  In this dialog  the parameters can be stored in a  separate file by clicking on    Save    in this dialog and can be later restored by clicking on    Read from  file   However  Allegria saves the last parameters entered in its own directory when the OK button is  pressed  and these are the parameters that will be used by erd2003 for a conversion    In the  Sample  tab  the user sets the working directory  the log file name  where the information  spitted off by erd2003 will be written   and a sample description for future references  Depth units  can be either in 1 x 10 6 at cm  or in ug cm      12    The working directory is where the mass separated energy spectra are located and where the depth    profiles will be generated after each iteration  Since many files are generated  the number of analyzed    elements times the number of iterations   it is strongly recommended that the user creates a separate    directory for each event file analyzed  This directory will contain the event file  the energy spectra     
5.  user to correct this    problem by rounding off the number of counts     Write selected element events in separate files Saves the events within each polygon in a  separate Allegria event file  This can be useful to save aside a list of events selected against  a certain criterion  and load them back later to do projections only with these events  Data  corresponding to each channel is saved in the Allegria event file format  The user is asked for  a directory name  and the files are saved with the same name as the original event file to which    the program appends the element symbol and the     dat  extension     3 Options specific to ERD TOF    3 1 Reshaping a curve    SpectrumExtractor offers the option of converting time of flight axis into a mass axis  thus reshaping  the stripes corresponding to each element so that they appear more or less horizontal on the graph     Figure 2  for example  shows a time of flight vs  energy plot for a sample that consists of a SiO   layer    on a silicon substrate  To use these options  the user must set the X axis as the energy and the Y axis  as the TOF in the Channel Selector dialog     Mass is calculated according to the following expression   m   2 E  E   t    t0   Ip     where Eo  fo and lo are parameters associated with the zeros in energy calibration  pulse height defect    the delay in the TOF measurement  and the camera length  respectively  Note that these values are  only proportional to the corresponding parameters as the
6. 4 as    spectrum  size     If your original energy data has more than 1024 channels  you must enter a    division factor     that will divide the number of channels so that it becomes smaller than 1024  Section 2 5 gives more  details on how energy spectra are computed according to these formulas and parameters    It is worth mentioning that the program keeps the event list in memory  and regenerates the data  displayed on the event graph each time a modification is made to the display or reshape parameters   Thus  trying to make operations  section 9  on the data as displayed on the graph is worthless  since    this data will be cleared and regenerated each time     2 3 Displays    Information on graph zooming and customizing can be found in part III  Once the user is satisfied with  the way his her data appears on the screen  this display can be saved for later use  The information  saved with a display includes the zooming boundaries if any  but more importantly  the formula  and channel selection made in the Channel Selector dialog mentioned above  Reshape parameters  associated with TOF  see section 3 1  are also saved    Up to five displays can be stored by selecting    Display  gt  Store current display as  from the menu   The user will be asked for a name for the display  Stored displays are restored by selecting    Display     gt  Recall display  from the menu or by clicking on the mm icon     2 4 Separating elements    Events associated to specific elements can be s
7. ALLEGRIA USER MANUAL    Fran  ois Schiettekatte  Martin Chicoine  Universit   de Montr  al    May 13  2004    Contents    Introduction 3  I SpectrumExtractor 4  1 Data files format 4  2 Obtaining energy spectra with SpectrumExtractor 5   AES  0029 M        PDI TT 3  2 2 Specifying display and energy projection parameters                     5  Lr DR cus ee Suite ER EERE DT DR X VR deus TR STARS 6  24 Separating clemnme  ts  CC  7    0 POON  o ne eR RHE REE REE REE HERR ER R REESE R E 7   0 BIDS QUEE  6 ae ter tes ES ES HE EUER OGUX SPEARS EASHASS 8  3 Options specific to ERD TOF 8  2 1 Reshaping ROVE 2 2524 E gh a3 Ex She Gas S RASA danger 8  2o DEDIERUDE CCN   222042 LD RSS i S m m PORE Ee Phe BES 9  3 3 Energy projection using time of flight                            11  II Allegria 12  4 Loading files 12  5 Setting experimental parameters 12  6 Conversion to depth profiles 14  7 File menu 15  III Graphs  data set options and operations 16  8 Zooming and customizing the axes 16  9 Data set operations 16    Introduction    Allegria is an analysis software package that features a versatile graphical user interface in order to  manipulate and convert various types of Elastic Recoil Detection  ERD  and Rutherford Backscattering  Spectrometry  RBS  data into depth profiles  as described in Ref     It extracts mass separated energy  spectra from multi parameter event list files  with SpectrumExtractor exe  presented in part I  and then  converts these energy spectra into depth p
8. a given Display  and will be applied on when  the Display is recalled  The reshaping procedure can be applied to graphs already reshaped  no need  to go back to the TOF vs  energy display     3 2 Separating elements    Once the element stripes have been reshaped  they can be easily separated  Each element must be  defined by a polygon that surrounds the events associated to it as described in section 2 4  To display  a polygon  click on the corresponding element on the periodic table on the lower right  Each element    must be defined this way     events graph   m x        events graph JE x        1  1   E  1  1  1    1  1  1  I  1    Time of flight  Time of flight    T  1  I  1  I       D 2000 4000   GDDD 2000 D 1000 2000 000 4000 4000  Energy Energy       Figure 2  a  Time of flight vs  energy plot of a sample that consists of a SiO   layer on a Si substrate    and b  same data reshaped as element mass vs  energy     10    3 3 Energy projection using time of flight    Energy calculations can be carried out using the time of flight instead of an energy channel  which  may provide better energy resolution especially for heavier atoms  First  a time spectrum is computed  according to the time of flight At   t        t  where t is the time on the Y axis  The time scale is then    remapped to an energy scale according to the following expression   E   mij   2At    Eo     where the parameters Eo  to and lo are those of the current reshape  and the mass m is the atomic mass  of ea
9. b must be specified the calibration parameters for all the elements that will    be converted  Elements can be added or deleted by clicking on    Add element    or    Delete element        The following parameters must be set     Element Element to be analysed     13    them        Figure 3  Definition of angles used in the experimental parameters window     Mass Mass of the element   Angle Angle of the detector  as defined in Figure 3   Ratio Solid angle detection ratio  relative to the monitor     Absorber Constituent of the absorber  If no absorber is used  input zero thickness in the    following item   dx  ug cm     Total thickness of the absorber  in ug cm       Slope  keV ch  Slope of this particular element  Alpha slope in the case of calibration calculated  using pulse height defects     Zero  keV  Energy at channel 0     Arho Parameter related to pulse height defects  see Ref  2    If this parameter is set to 0  the    energy calibration is simply calculated from slope and zero parameters   Method Lets the user choose the analysis method  ERD or RBS      File Energy spectrum file name  The     button can be used to select a file  All energy spectrum    files must be in the working directory     6 Conversion to depth profiles    Once all parameters are set and energy spectra specified in the Experimental Parameters dialog  conver   sion to depth profiles can be performed  This is done by typing CTRL g  by selecting    Conversion   gt  Go    or by clicking on the   ic
10. ch selected element  These spectra can be saved the same way as the usual energy spectra in    order to be processed in Allegria     11    Part II  Allegria    The purpose of the Allegria program is mainly to be an interface to the erd2003 program  erd2003  is the core of the software that has been running at the Universit   de Montr  al since the mid 70s to  analyse ERD and ERD TOF data  It has been reworked namely to include a stopping power calculation  based on the SRIM 2000 formula and parameters    Mainly through the dialog discussed in section 5  Allegria helps the user setting up the parameter  file that will be passed to erd2003  and reads back the resulting depth profiles     4 Loading files    This step is usually unnecessary for data that have been extracted using SpectrumExtractor  Data will  be loaded automatically when the user starts a conversion  namely to make sure they are available    Loading an energy spectrum will be helpful if the user wants to make some adjustments to the  spectra before they are converted by Allegria  This is usually the case if RBS data are analysed  The  user must separate each component of his spectrum corresponding to the different elements  and save  them in separate files  For this purpose  the functions discussed in part III will be very useful    To load an energy spectrum  right click in the    Mass separated energy spectra    window and select     Load file     Then  do the different operations required  and save the data by
11. eparated by defining polygons that surround the related  events in the    Events graph    window  The vertices of the polygon are defined by SHIFT Clicking  A  green cross will appear  Once all the vertices are defined  go to the menu    Display  gt  Define polygon     or click on the      icon  The user will be asked to identify to which element the polygon corresponds   Once a polygon is defined for an element  it will not necessarily show up  the user has to click on the  corresponding element on the periodic table on the lower right in order to display this polygon  Each  element that the user wants to extract must be defined this way    Polygons can also be defined for dummy elements Qa to Qp  This is useful when the user wants  to discriminate events on other criteria than mass or element number  As mentioned below  events  within a polygon can be saved separately in an Allegria event file to be treated at another time    Polygon coordinates are saved when SpectrumExtractor exits  If the program crashes for some  reasons  the polygon defined in this session will be lost  and the user will have to redefine them  If the  acquisition parameters are not changed from one spectrum to the other  e g  gain on the amplifiers   pressure in the gas counter   the polygon already defined should be reusable  even for different ion  beams and energies    The X Y coordinates of all the events can be saved in a separate file by right clicking on its legend  entry and selecting    Save  
12. ilitate elemental separation  values displayed against the x and y axis can be custo   mized with the X     and Y     menus  where there is a choice of a few pre defined formulas  A  B   C  and D menus list the detection channels available for the currently opened file  During an energy  projection  that is  the extraction of mass separated energy spectra   the energy value is computed  using the formula under    Energy calculation for projection     This allows more flexibility since both  X and Y axes can be used for event discrimination against other criteria  Energy spectrum of elements  for which events are collected by a single separated channel  e g  in the example of section 1  the third  detection parameter represents the energy of separately detected H  can be extracted according to the  formula and parameters selected under    Spectrum directly from channel     In all cases  selecting a  blank means that the parameter  or the formula  will not be computed    Parameters under    TOF reshape parameters  are described in section 3 1  Note that these values  are only proportional to the corresponding parameters as they are extracted from energies and times  expressed in channel number    The two parameters at the bottom indicate the size  number of channels  of the energy spectra that  will be generated during an energy projection  and a division factor  To be processed by the Allegria  program  erd2003  actually   spectra must have 1024 channels  so you must enter 102
13. ir values correspond to energies and time  expressed in channel number  These parameters are adjusted so that a given mass will appear as a  horizontal stripe on the display  Heavier elements may not have the same Ep as lighter ones  so a  single set of parameters is not suitable for all masses  Different sets can be saved as a Display and  recalled later by the user    Reshaping is done as follows  You must set three points on a given stripe that can be attributed to  a known element or isotope  Point setting is done by clicking with the SHIFT button pressed down   A green cross will appear  It is recommended to choose well separated points  as shown in Figure 2  a   and to zoom in and out during the process to precisely set the crosses  If the user is not satisfied  with his her point setting  crosses can be cleared by right clicking in the Events Graph window and  selecting    Clear markers   and then start over    After the three points have been set  the user selects    display  gt  apply reshape  from the menu or  clicks on the Z icon  The user will be asked to what element the stripe that was settled corresponds   The program will calculate the value of the three parameters so that the three crosses appear horizontal  at the value of the selected mass  The vertical axis will now be in mass units  as shown in Figure 2  b   although the axis title is not changed   The user may then zoom the region of interest and save  this Display  The Reshape parameters are saved with 
14. mbers represent channel numbers  between 0 and 8192  corresponding to the amplitude of  the signal recorded by the acquisition system during each event  It is seen that when the hydrogen  detector records a value  zeros are recorded by the TOF detector and vice versa  unless simultaneous    events occur     2 Obtaining energy spectra with SpectrumExtractor    2 1 Opening a file    To open a file containing a multi parameter event list  select    File  gt  Open Event File    from the menu  or click on the  amp  icon  Again  the file format must comply to the format specified above     2 2 Specifying display and energy projection parameters    By default  the first two columns of the file will be plotted as x and y in the    events graph    window     and the first channel will be considered as the energy channel  To change the display settings  select                         Display  gt  Channel Selector  from the menu or click on the  z  icon  The following dialog will show    up        E SpectrumExtractor   21xl    Display  for elements identification    xs  ARED    a            c    l o       vs  ACD    4 72 sz B   shes sm     s    Energy calculation for projection     Spectrum directly from channel     Sz              8      c    l o         TOF reshape parameters  set Camera length to    to avoid reshape     Camera length    364625 delay    8236 EO   42 3501    spectrum size    1024 division factor    8  Cancel         Figure 1  Channel Selector window     In order to fac
15. n one technique  it is  highly recommended to create copies of the program in separate directories so the program will save    the parameters specific to each technique in its own directory     1 Data files format    Allegria data files must be in a specific format to be accepted  This is in order to preserve the generality  of the program  As each lab probably uses its own data format  any attempt to comply with each  format would be impractical  Hence  users must write a patch in order to convert their data to the  Allegria event file format    Here is an example of an ERD TOF event file     Allegria event file  705152 3   885 3167 0   1772 4709 O0   512 2575 0   0 0 234  1892 4793 0  351 834 0  1274 4487 0  853 3265 0  3550 6478 0  0 0 356  1867 4837 0             On the first line must be written    Allegria event file     The program will not accept data files that  do not contain this line  This is to prevent users from opening wrong file types that might make the    program crash  On the second line are the total number of events  705152 in this example  and the  number of detection parameters for each event  3 in this example   On the following lines are listed  the detection parameters of each individual event  In this example  the first number is the energy  measured by a surface barrier detector located at the end of the TOF camera  the second number is  the TOF  and the third is the energy measured by a separate hydrogen detector  with an absorber foil    These nu
16. ng time is discussed below   Finally  a projection can be made against the Y axis  The projection will be computed for the grey  marked areas  CTRL click and drag   or for the entire data if no grey mark are set  Mass spectrum    can be obtained from TOF data using this command     2 6 Saving the data    After an energy projection is done  the user must save the mass separated energy spectra as they are  not saved automatically  There are three different saving options in the    file    menu  Only the second    one will save the data in the format appropriate for further analysis with the Allegria program       Write energy spectra in a single file A single multi column file is written with Energy in the  first column and corresponding number of counts for each element in the following columns   This is not the format usable by Allegria but it may be useful if you want to import the energy    spectra in a spreadsheet  for instance     Write energy spectra in separate files This is the good one  One spectrum file is written for each  element  Its extension will identify the element  The extension for a silicon spectrum would be   SLSPC  for example  In the first column is energy channel number  and in the second column  is the corresponding number of counts  Be careful  if math operations such as division were  performed on a data set  fractional numbers of counts will be written  Such fractional number  of counts cannot be read by erd2003 exe  An option in Allegria allows the
17. on  Allegria will load all the energy spectra to make sure they are    available  If any data is present in the energy spectra graph  the user is asked if the program may clear    14    The erd2003 conversion engine is then started  Under Windows  a Console will show up  indicating  the number of iterations  In Linux  this information will be displayed in the console where Allegria  was started    If an error occurs  Allegria will prompt the user  The program execution logfile can be opened by  selecting    Conversion  gt  Show ERD output    from the menu  However  if a Fortran error occurred   it will not appear in the log  Most of the time  this is caused by passing a spectrum containing non  integers to erd2003    The user can select    Conversion  gt  Surface energies    from the menu  The dialog displays the  surface energies obtained during the last erd2003 run for the different elements after they passed  through the absorber  be careful  this is a little bit misleading   The user can input surface channel  number corresponding to each element  This can help setting the energy calibration  but things such  as pulse height defects are not taken into account  Fairly good values can usually be obtained from  light elements  though     Frequent reasons for which erd2003 will not produce the desired output include     calibration parameters not set properly    wrong beam  beam energy or angles      normalization channels not set properly    7 File menu    The following opti
18. ons are given in the File menu     Save selected energy spectrum as integer Saves the energy spectrum  keeping only the integer  part of counts  The ERD program can only process spectra with integer numbers of counts     Write energy spectra in a single file Writes the energy spectra in a file where energy is in the    first column and numbers of counts for each element are in the other columns     Read ERD depth Profile Loads a depth profile in the    Depth profiles window   Concentrations  in depth profiles are multiplied by 10000  This function divides the concentration by 10000  after reading a depth profile     Write depth profiles in a single file Writes the depth profiles in a file where depth is in the first    column and concentrations for each element are in the other columns     15    Part III    Graphs  data set options and operations    8 Zooming and customizing the axes    Zoom can be applied by simply left clicking and dragging inside a window  To unzoom  click the    right button and select the  unzoom  option     Axis labelling and formatting can be changed by right clicking on the axis label and changing    the various options offered there  Logarithmic scale can be selected and switched back to a linear    scale  Axis labeling is changed by selecting    Edit axis   Superscript and subscript can be obtained    by typing  t     and              Greek symbols can be obtained by typing    xxx   where xxx is    one or more normal  latin  letters  The equivalence
19. rofiles for each mass  with Allegria exe as an interface to the  erd2003 exe program  presented in part II   The resulting atomic fractions are normalized to one of  the elements present in the analyzed sample  Part III explains all the different operations and options  that apply to graphs in both programs  such as zooming  renaming the axis  and manipulating data  sets    Hyperlinks are inserted in the text and can be used to facilitate navigation  This manual is not  complete yet  More examples will be added soon  Users    questions  comments and suggestions are    welcome and can be sent to the authors     about the manual and instructions  Martin Chicoine  martin chicoine  umontreal ca        about the programs bugs glitches  Fran  ois Schiettekatte   francois schiettekatte   umontreal ca        Part I    SpectrumExtractor    As indicated by its name  SpectrumExtractor is used to extract mass separated energy spectra from a  list of multi parameter events  It has been designed to be flexible so one can use it to extract spectra  from the data produced by techniques such as ERD Time of Flight  TOF  or ERD EAE  If angular  information is available from the detection parameters  as it is usually the case for ERD EAE  for  instance   spectra can also be extracted for different scattering angle intervals    Many SpectrumExtractor parameters are relatively specific to the technique used  for example   the polygon used to define an element   If you use the program with more tha
20. the profiles obtained after each iteration  and the logfile and parameter file  Allegria exp  from the  last erd2003 run     In the    Beam Conversion    tab  the following parameters must be set     Element lon beam used for the measurement  The element is selected by clicking on the square    button    Mass Mass of the beam ion    Energy Energy of the ion beam    Beam angle Incident angle of the ion beam  as defined in Figure 3      Monitor The concentrations obtained in the depth profiles will be expressed as a fraction of a  given element  usually a substrate element of known concentration   This element is selected  by clicking on the square button beside    monitor        Lower  amp  upper normalization chan  The lower and upper energy channels used for this    normalization must be specified     Alpha slope Slope of the  amp  particles calibration for the detector  This is used to correct for  pulse height defects  see Ref  2       Iterations Number of iterations for concentration calculation  3 iterations is usually enough   but some cases require more  change this value to see if it changes the solution   For stopping  power calculations  only the element chosen as monitor is considered during the iteration 0   The concentrations are then calculated according to the concentration found in the previous    iteration   Step size Depth calculation interval  specified depth units      Minimum energy Lowest energy considered for the calculation     In the    Elements    ta
21. the whole data set   Also  if an axis is set to log  the fit will be done on the log value of the data  Thus  a 2nd order  polynomial fit made on a peak on a semilog graph  log Y  linear X  will appear parabolic on  the semilog graph  and gaussian if the Y axis is set back to linear  Similarly  a linear fit on a  log log graph will show up as a power law  y     ax   in linear mode     References     1  E  Schiettekatte  M  Chicoine  S  Gujrathi  P  Wei and K  Oxorn  Nucl  Inst   amp  Meth  B 219 220   125  2004       2  B  D  Wilkins  M  J  Fluss  S  B  Kaufman  C  E  Ross and E  P  Steinberg  Nucl  Inst   amp  Meth  B  92  381  1971      17    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Canules trachéales TRACOE Twist - TRACOE Medical  COMMUNE de Bougy  D2nc User Manual  HP ePrint & Share, das dieses Benutzerhandbuch - Hewlett  Axor 41238800 User's Manual  questions-réponses  Lirio by Philips Table lamp 57067/32/LI  Manuel d`utilisation du Bureau GNOME 2.0 pour l`environnement d  取扱説明書 - Panasonic    Copyright © All rights reserved. 