Operating Instructions for pressure transmitter with

image

Contents

1. Set 2nd position Set 3rd position Adjust decimal point Save selected value or re enter to the next main menu item PDA 12 02 page 7 PDA 10 Set up mode 3 sec Y J Code input Cod O _ Value setting 8 Y Start current gon O 7sec 5 Value setting Store Start current Y End current O 7sec Q Value setting Store End current 0 30 a a 0 OE i Je E ua 20 o O o Filter Ea Q Q 7 levels Value setting Y Start adjustme justmept SP 4 sec Q Value setting Store start point Y Y Code change Ela O Q Value setting T ae page 8 PDA 12 02 PDA 11 Main menu items 11 1 Current output The current output is set in menu items S C Start current indicated value lt gt 0 4 mA E C End current indicated value lt gt 20 mA SCS Start current selection 0 20 mA or 4 20 mA The indicated value at which 0 4 mA is transmitted is entered in menu item Start current The indicated value at which 20 mA is transmitted is entered in the menu item End current 11 2 Filter The filter function Filt generates the sliding average value from the measured values This acts to dampen the output in a system which has pressure pulsations The following values are available see Section 9 Settings 1 2 4 8 16 32 64
2. The filter value determines the dynamic behaviour of the indicated value high values mean a slow display with smoother response The filter is disabled if a filter value of 1 is selected In other words the indicated value is equal to the unfiltered measured value no dampening occurs The integrated step detector responds to a measured value step change greater than approximately 6 25 of the upper range value When a measured value step change is detected the actual measured value is displayed immediately 11 3 Start adjustment The zero point can be recalibrated when the sensor is in the unpressurized state As a security precaution the operator must hold the 4 key pressed for 7 seconds before he can activate Value setting menu item S A 11 4 Change Code Change code CCo protects the device against unauthorized changing of the set device parameters by allowing the operator to enter a secret code If the code set is different to 000 then the operator must enter the set code before entering the set up mode PDA 12 02 page 9 PDA 12 Technical Information Case cover Connections Gasket Principle of measurement Display Resolution Max temperature Overpressure Supply Power consumption Electrical connection Output Load Settings Overrange underflow indication Measuring cycle Accuracy Protection type page 10 stainless steel 1 4305 G 1 4 or G 1 2 male thread stainles
3. amp Safety and prevention of accidents 3 Regulation use Pressure transmitters are used to measure pressure in vessels hydraulic and pneumatic plant refrigeration equipment and so forth Any use of the pressure transmitter PDA which exceeds the manufacturers specification will invalidate the warranty and any resultant damage is therefore not the responsibility of the manufacturer The user assumes all risk for such usage 4 Operating Principle The KOBOLD pressure transmitters model PDA are electronic measuring instruments with a digital display of the system pressure There is an output signal 0 4 20 mA for transmission The sensor element is a piezoresistive ceramic cell The PDA is used wherever exact pressure measurements with compact local display is required The PDA is perfect for industrial use because of its high long term stability save reproducibility and its small robust package PDA 12 02 page 3 PDA 5 Instrument Inspection Instruments are checked before shipping and should arrive in perfect condition In case of damage please inform your local Kobold office or your parcel forwarding agent immediately since they are responsible for damages during transit Should the damage to a device be visible we recommend a thorough inspection of the delivery packing Scope of delivery e Pressure transmitter PDA e Operating Instructions 6 Mechanical connection Pressure taps should be prepared
4. Operating Instructions for pressure transmitter with digital display Model PDA OBOLD uU O PDA 1 Contents page 2 DD O oda O 11 Regulation USE iieii cel ent esc cee ei Operating Principle xs 0d ai ad Instrument INSpectiON occccccconnnnnccnoncconcnccnnnnnnnnnnnnnnnonnnnnnos Mechanical connection ici Electrical COMME COM ascetics ss ps ae COMMISSION tada Sl Key TUCU naie ell teh cleat el Muh ete eed Configuration samp oe O12 Valle Setting cc ii Se lp MOUS id A ads Mai mentr MEMOS a td dd dd oa TE la Current output eeen dana Zo PEE a Nc 11 3 StartadjustMenta rial id id trizas 1 4Ghange Coda ado i dl a Technical Informati0N occcocccnccccncncncncnocnnncncnanonannnnnccnanononanon As A ns Oer IMAI EMA CS ts NED IN DIMENSIONS td it dt blas Declaration Of Conformance occoocccconcnnconcnncononoconnnncononoconnnnnnnos Manufactured by Kobold Messring GmbH Sold by Komponentautomatic AB Box 265 771 26 Ludvika Tel 46 0 240 150 09 Fax 46 0 240 61 11 08 E Mail info komponentautomatic se www komponentautomatic se PDA 12 02 PDA 2 Note Please read these operating instructions before unpacking and putting the unit into operation Follow the instruction precisely as described herein The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health
5. according to the following specifications for the screw in holes Gaskets to DIN 16 258 or formed gaskets are recommended for sealing British Standard Parallel Pipe thread BSPP The required tightening torque depends on the material and shape of the gasket used and on the pressure port in the pressure sensor National Pipe Thread NPT fittings should be sealed with an appropriate pipe thread sealant Exposure to violent shocks and heat radiation should be avoided The permissible service conditions for the pressure sensors should be observed When the pressure connection has been made and the power supply connected the sensor is ready for operation Sealing according DIN 16288 Sealing with Flat gasket page 4 PDA 12 02 PDA 7 Electrical connection Important Make sure that the voltages in your plant correspond with the voltages on the nameplate e Make sure that the electrical supply lines are dead e The supply is connected through connector socket M12x1 as shown in the wiring diagram below e Mating plugs with different cable lengths are available as options Important The instrument electronics may be damaged if the cable connections are connected incorrectly Connector pin assignment PDA weiR white 2 2 nicht belegt n c a ES AEn 1 braun brown A e Ub Supply schwarz black LO Ne 4 bl Nee A E usgang Outpu OV Ground Option Plug wit
6. g 14 Maintenance The instrument requires no maintenance when properly used Deposits due to fouled media can give rise to invalid measured values PDA 12 02 page 11 PDA 15 Dimensions Connection cable gland Connection Connection Info The matching M12x1 box with 2 m cable for the M12x1 plug connector is available under order code ZUB KAB 12K002 Fig with box page 12 PDA 12 02 PDA 16 Declaration of Conformance We KOBOLD Messring GmbH Hofheim Ts Germany declare under our sole responsibility that the product Pressure transmitter with digital display model PDA to which this declaration relates is in conformity with the standards noted below EN 50081 1 1992 Electromagnetic compatibility EMC Interference emission in the home EN 50082 2 1995 Electromagnetic compatibility EMC Noise immunity in industry EN 61010 1 1993 Safety requirements for electrical measuring control and laboratory instruments Also the following EWG guideline is fulfilled 89 336 EWG ao Vu Signed date 05 10 01 H Peters M Wenzel PDA 12 02 page 13
7. h cabel Plug Wiring diagram 2 i 1 fa EN Ub Supply ls I Ausgang Output AY T A N Q t OV Ground Plug PDA 12 02 page 5 PDA 8 Commissioning Caution Please note that if operated at high system temperatures the case surface and controls can become very hot Connect the pressure transmitter according to the wiring diagram above and supply it with the specified voltage The measuring range upper range value is displayed for 3 seconds after switch on 8 1 Key function Normal mode measuring mode Press for 3 Sec gt set up mode O Display Low High current value Set up mode Q Next level Any time 3 sec y O Change value or 20 sec Without pressing any key Y Normal Mode page 6 PDA 12 02 PDA 9 Configuration The following values can be programmed on the pressure transmitter Range of values Factory setting Start current S C zero O to upper range value 0 End current E C span O to upper range value upper range value Start current selection SCS 0 4mA 4 Filter Filt 1 2 4 8 16 32 64 1 Start adjustment S A tare 000 adjusted Change Code CCo 000 999 000 9 1 Value setting Value setting can be selected with the 4 key in the main menu item for example End current E C The standard sequence for changing parameters is given in the flowchart below from the main menu item Set 1st position Set 1st position
8. s steel 1 4404 option 1 4 or 1 2 NPTF others on request Viton option EPDM monolithic ceramic sensor 3 digit LED height of digits 7mm max 0 01 bar depending on measured value and measuring range 20 to 80 C medium 20 to 80 C ambient 3 fold measuring range lt 60 bar 2 fold 100 bar lt measuring range lt 250 bar 1 5 fold measuring range 400 bar 24VDC 20 approximately 80 mA plug connector M12x1 option cable on request 0 4 20 mA max 500 ohm programmable with 2 buttons 4 20 mA or 0 20 mA factory setting 4 20 mA start point end point current filter zero point security code on LED display 0 5 sec 0 5 f s IP 65 PDA 12 02 PDA 13 Order Codes Model Description Electrical Mechanical Measuring range connection connection PDA 15 Pressure 3 Plug M12x1 R2 G 1 4 C315 1 to 0 bar transmitter with 1 1m PVC cable R4 G 1 2 BO25 Oto 1 bar digital display 9 length of cable N2 1 4 NPT B035 0 to 1 6 bar and analogue in meters N4 1 2 NPT B045 0to 2 5 bar output BO55 0to 4 bar Stainless steel B065 0 to 6 bar housing B075 0 to 10 bar B085 0 to 16 bar A095 0 to 25 bar A105 0 to 40 bar A115 0 to 60 bar A125 0 to 100 bar A135 0 to 160 bar A145 0 to 250 bar A155 0 to 400 bar Additional Electrical connection Model ZUB KAB 12K002 ZUB KAB 12Q000 Description M12x1 Box with 2 m Cable M12x1 Box with Quickon Plu