1. EtherHaul 1200 Gigabit Ethernet Wireless Solution Installation Manual EH1200 INST 04 Issue 2 February 2015 ALL RIGHTS RESERVED TO SIKLU COMMUNICATION LTD EH 1200 Installation Manual Trademarks Siklu the Siklu logo and EtherHaul are all trademarks of Siklu Communication Ltd All other product names and trademarks mentioned in this document are trademarks or registered trademarks of their respective companies Copyrights Copyright 2014 Siklu Communication Ltd All rights reserved No part of this publication may be reproduced or distributed in any form or by any means or stored in a database or retrieval system without the prior written consent of Siklu Disclaimers The information contained in this document is subject to change without notice Siklu assumes no responsibility for any errors that may appear Siklu makes no warranties expressed or implied by operation of law or otherwise relating to this document the products or the computer software programs described herein This document was originally written in English Please refer to the English language version for a full and accurate description of all products and services described herein Page 2 EH 1200 Installation Manual Safety and Regulatory Notices The following are mandatory notices for installation and operation of EtherHaul Wireless Backhaul Link Indications appearing here are required by the designated
2. Current operational mode of the link o Alignment Carrier Wave transmission Used for antenna alignment No data over the radio link o Static Fixed modulation profile If you select Static you must select from a list of pre configured modulation profiles in the Modulation field o Adaptive Adaptive Bandwidth Code and Modulation The system will work on the highest modulation profile based on the CINR values of the both sides and will present the current modulation profile e Estimated Throughput Mbps based on the current modulation profile o For FDD systems value is Full Duplex o For TDD systems value is aggregated Half Duplex Page 36 EH 1200 Installation Manual Note Actual Layer 1 throughput depends on product s specs Refer to the EtherHaul A Release Notes for exact specifications e Current Alarms list of currently active alarms and date amp time raised e History Log System alarms and events history log e User Activity Log All configuration changes are logged including user and date amp time presented in the form of CLI commands Note i To view logs pop ups must be enabled and allowed on your Internet Browser Page 37 EH 1200 Installation Manual 3 3 3 3 1 3 3 2 3 3 3 General Configuration Commands Apply Any configuration change is executed upon clicking Apply The Local Remote concept of the Web Based Management allows configuring both loc
3. Save Remote Configuration Reset Remote Figure 3 3 Web Based Management Main Page Page 35 EH 1200 Installation Manual 3 2 Main Page The Web Based Management provides link view presenting both local and remote configuration and monitoring Although the local and remote systems IP address is identical default IP address 192 168 0 1 the remote will be available as well as the EtherHaul uses dedicated communication channel for local remote communication that is not IP based It is recommended however to assign dedicated IP address for local and remote systems Note Depending on your station s screen size and resolution you may need to scroll the screen vertically or horizontally in order to view all options for local remote a Alternatively you may change the change the Internet s Browser display distance Zoom out using Ctrl Minus The Web Based Management Main page is a read only page and displays the following information e Link Status Link up or down with visual indication e Link Length m link calculated distance between the local and remote systems air distance based on propagation time e Tx Rx frequency MHz e RSSI dBm Receiver Signal Strength Indicator Current receive level CINR dB Carrier to Interference Noise ratio Indicates the current radio link s signal quality In normal conditions CINR219 indicates a good signal quality e Mode
4. of the All Weather shell from its ODU port Remove the cable connector from its port Connecting DC Power d Carefully screw the connector outlet portion of the All Weather shell into the PWR port Tighten the connector outlet portion securely by hand do not use tools Insert the power connector into the port The PWR LED color indicator turns red for one second then blinks green indicating that the ODU is powered on Screw the cable inlet portion 0 of the All Weather shell onto the secured connector outlet portion taking care not to twist the connecting cable Tighten the cable inlet portion securely by hand The rubber gasket insert will tighten to create a moisture proof seal do not use tools Secure the power supply cable into place using a cable tie Ensure that there is sufficient play in the cabling to allow movement of the ODU during final alignment Wait for the EtherHaul ODU to boot up about two minutes When the ODU is fully rebooted the PWR LED color indicator turns green during power up the PWR LED blinks green and the RF LED color indicator turns off indicating that the link is down Connecting Other Interfaces For each network connection perform the following steps 6 Carefully screw the connector outlet portion of the All Weather shell into the appropriate port Tighten the connector outlet portion securely by hand do not use tools Insert the RJ45 or SFP connector into th
5. slightly to allow the ODU some freedom of movement 3 Perform a coarse ODU alignment using a line of sight visual check with the remote EtherHaul ODU Lock the unit mounting bolts using the 13mm open wrench 4 Repeat steps 1 to 3 above on the remote ODU Fine Alignment When aligning an antenna the antenna in the remote node must remain completely stationary Perform Fine alignment first on the local antenna and only afterwards on Note the remote antenna A The optimum alignment may require several adjustment iterations between the local and remote antennas 5 Connect the DVM to the ODU by inserting both red and black probes into their appropriate positions in the AUX port Page 31 EH 1200 Installation Manual 2 11 10 EE 12 13 14 15 Throughout the alignment procedure you must compare the actual receive signal strength indication RSSI to the expected RSSI that was calculated during network link budget preparation refer to Preparing for Installation on page 20 Read the receive level RSSI using the DVM The voltage reading will be between 0 to 1V indicating the RSSI in dBms For example a DVM reading of 0 45V is equivalent to 45 dBm Align the fine Azimuth axis Use the hexagonal wrench to adjust the Azimuth fine adjustment screw Be sure to sweep the complete range of the Azimuth in order to determine the maximum received signal strength position When the optimum axis is achie
6. Adaptive Mode Note that different modulation tables may apply according to product used the frequency channel used and ARQ status The modulation profiles and thresholds are optimized and should not be modified can be configured via CLI only after consulting Siklu support 3 5 5 Statistics Radio link s performance can be monitored using the advanced statistics counters Refer to the Statistics chapter of the EtherHaul Operation Administration and Maintenance Manual for detailed description of the system s statistics Page 48 EH 1200 Installation Manual 3 6 Default Bridge Configuration The default system s configuration is IEEE 802 1d Transparent Bridge In this mode all traffic both tagged and untagged is transparently forwarded between all ports and over the radio Page 49 EH 1200 Installation Manual 4 1 4 1 1 4 1 2 4 1 3 Commissioning and Acceptance Procedure This chapter presents the recommended commissioning and acceptance procedure to be performed following the installation of each EtherHaul radio link The commissioning and acceptance procedure verifies the correct installation and the proper safe and robust operation of the EtherHaul RF link This chapter includes the following topics e e Installation Verification and Testing EtherHaul Commissioning and Acceptance Form Installation Verification and Testing Inspect the following components and confirm their adherence to r
7. E 5 ot a Inactive QAM64 4 1 0 5 7 Adaptive Alignment Static 50TX 50RX iv Network Services Status Link Up Advanced Config e Copy to Remote gt gt Copy to Remote gt gt Copy to Remote gt gt Statistics Help REMOTE Name left_slave 500 v 74375 v 5 Be H 100 35 22 WE ANM 0 25 Inactive QAM64 4 1 DE sl Adaptive Alignment Static 50TX 50RX_ sl Figure 3 9 Radio Page Settings e Channel Bandwidth MHz 500MHz e Tx Frequency MHz transmit frequency Rx Frequency MHz R O field updated based on Tx frequency o For TDD systems identical Tx and Rx frequencies Logout Page 44 EH 1200 Installation Manual Tx Power dBm ODU s transmit power Default is the max power based on product s specs Minimum configurable Tx power is 35dBm note that actual minimum Tx power is based on product s specs Note threshold Adjust Tx Power so the RSSI at the remote end will not exceed 35dBm overload The Tx power value sets the transmit power for the highest modulation profile In case lower modulation profile s has higher max Tx power based on product s specs the Tx power will be increased automatically without indication in RF configuration menu Mode operational mode of the link o Alignment Carrier Wave transmission Used for antenna alignment No data over the
8. Ki Auto Ki Maintenance Link ID TEO Rx 0 TsO Rx 0 Modulation Table E seals S WM Status Established Wl Status Established Statistics Comes QPSK 140 5 Vv QPSK1405 v Figure 3 10 Radio Page Advanced Settings This section allows configuring the following parameters Long Range Mode checkbox to enable extended range mode feature is license dependant e Normal links from 0 to 5Km Long links from 5 to 10Km e Extra Long links from 10 to 15Km Encryption checkbox to enable Encryption and field to enter the static key The EtherHaul supports 128bit and 256bit AES encryption with Static key This means that the encryption key 32 characters long for AES 128bit or 64 characters long for AES 256bit must be inserted manually into both ends of the link If there is an encryption mismatch traffic does not go over the link Encryption is a licensed feature that requires license for operation Before configuring it verify that license is available and enable the encryption license component Role Determines whether the ODU functions as a master or slave In a link one side must be set to Master and the other side must be set to Slave required for link synchronization Default value is Auto meaning the role is set automatically by the link Manually setting the Role is necessary only for asymmetric configurations Transmit Asymmetry Default value is symmetric configuration 50 for Tx and
9. Rx 50tx 50rx For an asymmetric configuration 75 25 or 90 10 Role has to be set the Master unit transmits the higher rate 75tx 25rx or 90tx 10rx and the Slave unit the lower rate 25tx 75rx or 10tx 90rx Link ID unique Tx and Rx Link IDs for links installed on the same site to avoid locking on the wrong transmitter Link IDs must be identical on both ends for the link to be operational ARQ checkbox to enable the mode and field to view the current status Page 46 EH 1200 Installation Manual 3 5 3 The ARQ Automatic Repeat Request is an algorithm that uses selective repeat retransmission to eliminate radio BER The default mode is Enabled When both sides are enabled and radio link is up ARQ status will be Established Disabling the ARQ mode is not recommended as it may result in radio BER e Lowest Modulation Lowest modulation profile When modulation drops below this threshold radio link will be down It is used to limit the minimal modulation profile of the link Default is QPSK 1 40 5 lowest available Maintenance Settings RF Loopback Wl Timeout sec 1600 Modulation v Advanced Settings Mute Timeout sec 60 Maintenance Modulation Table Statistics Figure 3 11 Radio Page Maintenance This section allows configuring the following parameters RF Loopback checkbox to enable the internal RF loopback set the timeout for clearing the loopback in seconds and sel
10. government and regulatory agencies for purposes of safety and compliance General Do not install or operate this System in the presence of flammable gases or fumes Operating any electrical instrument in such an environment is a safety hazard European Commission This product has been designed to comply with CE markings in accordance with the requirements of European Directive 1995 5 EC This product has been designed to comply with the requirements of European Directives This equipment must be permanently earthed for protection and functional purposes To make a protective earth connection use the grounding point located on the System ODU using a minimum amount of 16AWG grounding cable or according to local electrical code This apparatus is intended to be accessible only to authorized personnel Failure to prevent access by unauthorized personnel will invalidate any approval given to this apparatus This product is in full compliance with the following standards RF EN 302 217 3 1 3 1 E Band FCC part 101 e EMC EN 301 489 4 e Safety IEC 60950 e Operation EN 300 019 1 4 Class 4 1E e Storage EN 300 019 1 1 Class 1 2 Transportation EN 300 019 1 2 Class 2 2 FCC IC Regulatory Statements This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules and IC RSS standards These limits are designed to provide reasonable protection against harmful interferenc
11. networking 8 levels of QoS enhanced Hitless Adaptive Bandwidth Coding amp Modulation for maximum spectral efficiency and services availability It supports network synchronization advanced OAM amp PM tools and ring protection optimized for both small cell and mobile backhaul It features multiple GbE interfaces including optical supporting complex network topologies such as daisy chain ring and mesh The multiple ports enable also colocation installation and leveraging the infrastructure for additional fixed services delivery The EtherHaul is fast simple and inexpensive to deploy EtherHaul as the ideal solution for mobile backhaul and business services delivery features e Field proven technology Reduced TCO and fast ROI All outdoor invisible footprint o Small and light o Quick and easy to install e Spectral efficient o Wide range of frequencies o TDD modulation with seamless delay and jitter o Hitless Adaptive Bandwidth Coding and Modulation for high availability Advanced layer 2 features o MEF compliant services and QoS o VLAN amp Provider Bridge with 16K jumbo frames support Clear separation between multiple services with QoS Enables QoS aware MPLS services delivery o SLA assurance e Advanced AES encryption for secured street level deployments Page 10 1 1 EH 1200 Installation Manual Highly scalable the EtherHaul products are software upgradable to support future Layer 2 5 3 networking and r
12. power management Volts DC Volts DC reading come om om Page 52 EH 1200 Installation Manual Channel width 250MHz _ 500MHz 250MHz 500MHz JAuto JAuto Master Slave Master Slave Modulation Mode Adaptive Adaptive Mode modulation sub channel repetitions FEC Static IStatic UL DL Configuration ISymmetric JAsymmetric ratio Ethernet Services Tests Frame Loss test No Frame Loss No Frame Loss Packet Analyzer SW based Test duration Test duration JEtherHaul Statistics Page 53 EH 1200 Installation Manual IP address 1 amp C Details I amp C Date Page 54
13. radio link Note the radio link When exiting Alignment mode perform system reset to allow proper operation of o Static Fixed modulation profile If you select Static you must select from a list of pre configured modulation profiles in the Modulation field o Adaptive Adaptive Bandwidth Code and Modulation The ODU will work on the highest modulation profile based on the CINR values of the both sides and will present the current modulation profile Adaptive mode is the normal and recommended mode of the radio link Alignment Status R O field indicating that the ODU is currently in Alignment mode by configuration or by inserting DVM probes Transmit Asymmetry Default value is symmetric configuration 50 for Tx and Rx 50tx 50rx For an asymmetric configuration 75 25 or 90 10 Role has to be set the Master unit transmits the higher rate 75tx 25rx or 90tx 10rx and the Slave unit the lower rate 25tx 75rx or 10tx 90rx When selecting asymmetric configuration Role will be set automatically refer to Radio Advanced Settings Page 45 EH 1200 Installation Manual 3 5 2 Advanced Settings Settings C Static key 92E3C28020570998E74B41C06A58BB40 L Static key 92E3C28020570998E74B41C06A58BB40 s Encryption Advanced Settings Copy to Remote gt gt Long Range Mode Normal E Normal sel Role Auto
14. remote NMS stations 4 1 6 Recording ODU Configuration Perform the following steps after the EtherHaul ODU is commissioned and accepted 1 Copy the Running Configuration currently active to Startup Configuration 2 Save the configuration file for future records and backup 4 2 EtherHaul Commissioning and Acceptance Form EtherHaul Commissioning and Acceptance Form Customer Details Physical Installation Verification Local Site Remote Site Site name amp address Mount type JRoof top Roof top _ Mast Tower JMast Tower JOther JOther Page 51 EH 1200 Installation Manual Clear line of sight ODU safely mounted using Siklu s LJ Yes LJ NO LJ Yes LJ NO bracket correctly installed Pole diameter according to mount Yes No LJ Yes LJ NO specs Bracket s mounting bolts securely _ Yes _ No _ Yes _ No tightened Cables Fibers connections Eth1 Cat5 Eth1 Fiber JEth1 Cat5 JEth1 Fiber mark all cables connected JEth2 Cat5 JEth2 Fiber JEth2 Cat5 JEth2 Fiber JEth3 Cat5 JEth3 Fiber JEth3 Cat5 JEth3 Fiber _ Eth4 Cat5 JEth4 Fiber JEth4 Cat5 JEth4 Fiber _ Dc Cloc Cables Fibers securely routed and Yes _ No _ Yes No fixed properly using cable ties Cables Fibers are properly Yes LJ NO LJ Yes LJ NO weatherproofed using the appropriate glands ODU DC source PoE JExternal DC PoE JExternal DC PoE model and manufacturer Measured DC
15. Bi antenna gain e PoE IEEE 802 3at Power options e Direct Telco DC 21 57VDC VLAN IEEE 802 1q and VLAN stacking Q in Q IEEE 802 1ad Provider Bridge IEEE 802 1d Transparent Bridging Ethernet features Advanced QoS amp Traffic management 802 1p DSCP amp MPLS EXP O Scheduling Shaping Policing MEF 9 14 and 21 compliant Ethernet OAM and CFM IEEE 802 1ag ITU T Y 1731 IEEE 802 3ah Page 14 EH 1200 Installation Manual e Ethernet Ring Protection ITU T G 8032 e MAC learning e Link state propagation e Jumbo frames oak e Synchronous Ethernet ITU T G 8261 8262 8264 Synchronization J Network topologies Ring daisy chain and mesh e In band out of band embedded CLI web GUI SNMPv2 3 Adaptive modulation System modes Symmetrical uplink downlink ratio or Asymmetrical Alignment Operating temperature 45 50 C Environmental Ingress protection rating IP67 24 5 cm x 22 5 cm x 7 cm ODU 1ft Antenna Dia x Depth 31 cm x 13 cm Weight ODU antenna 1ft 4 kg Dimensions and Weight 1 4 Licensing The EtherHaul family provides for easy migration to support Gigabit throughput enabling operators to enhance bandwidth capacity on a pay as you grow basis as well as adding features and capabilities according to their networks evolutions You can order the following EtherHaul software capacity steps and feature availability depend on your platform e Data rates e Layer 2 networking capabiliti
16. Configuration Wizard sosmmossesssersserrrsserssserrerrrrrerrrrerrrerrrrerrrrrrrserrrsrrr sens rr rrrsrrrr rr na 40 34 1 Quick Contieuration Step l Syste Merissa 40 3 4 2 Quick Configuration Step 2 Radio s ssesssersserorsersssrsrserrrrrrsrrerrrrerrrrrrrrerrrrra 40 3 4 3 Quick Configuration Step 3 Eth Rote 42 3 4 4 Quick Configuration Step 4 Network 43 GG Mae 2 Te E AA SS Dh e 44 e NON ANC COS EE 46 BD EE 47 S04 Modulation Tall eer 48 E E e Stolta b ssor ere RR ALE 48 S20 Dert BIC Se Oni UTA N D EE 49 4 Commissioning and Acceptance Procedure ccccssccesseeseseseeseseeseseees 50 4 1 Installation Verification and lIespng 50 A A Physical Installation V crilicanon suse ene 50 AZ et E 50 AMS NSIT OLS KE 50 AW Ethernet SCL RE 51 Skelett 51 4 1 6 Recording ODU Configuration s ssssssersssrrsserrsererserrrerrserrrrrrrrrrrrrrrr sens srrrr rr rr rn 51 4 2 EtherHaul Commissioning and Acceptance Form 51 Page 8 EH 1200 Installation Manual TABLE OF FIGURES Figure 1 1 Hitless Adaptive Bandwidth Coding and Modulation ssssrrsssersrsersrsrerrrrrerrns 13 Figure 1 2 EH 1200 TDD Functional Block Diagram sssssssssrsssrrssrrrserrrrerrrerrerrrrrrerrrrrrr sera 14 Figure 2 1 EtherHaul Mounting Assembly Components ra 21 Pree 2 2 QUICKIES Eeer 22 Fizure 2 3 EtherHw l ODU Oger 23 Figure 2 4 EtherHaul ODU installed on 2ft Antenna sssseresssrrrrrerrrrrerrrrrerrrrrrrrrrrrrrrrrrrr
17. DHCP o Index 1 4 o Type Static or DHCP o IP Address Default is 192 168 0 1 o IP Prefix Length Default is 24 equivalent to Mask of 255 255 255 0 o VLAN 0 not defined meaning the IP is not associated with specific VLAN Click the Trash icon to clear an IP Note you cannot clear the IP address you used to log in to the system e Default Gateway e SNMP Managers Up to five managers that will receive SNMP traps can be configured SNMPv2c or SNMPv3 o Index 1 5 o IP Address Destination IP Address o UDP Port port number for sending traps Page 43 EH 1200 Installation Manual o Security Name community o SNMP Ver SNMP version SNMPv2c or SNMPv3 o Engine ID Used for SNMPv3 Click Apply to execute the configuration changes or Back to return to previous section The radio link parameters and radio link monitoring are managed in the Radio page Eh Pons System LOCAL 192 168 0 1 Name right_master 3 5 Radio Page This chapter includes the following topics e Settings e Advanced Settings e Maintenance e Modulation Table e Statistics 3 5 1 Settings Quick Config Main Magic th The ei Advanced Settings Maintenance Modulation Table Statistics This section allows configuring the following parameters Channel Bandwidth MHz Tx Frequency MHz Tx Power dBm RSSI dBm CINR dB Alignment Status Mode Transmit Asymmetry 500 iv 74375
18. Wahser 5 16 Antenna Base Lock Flat Washer 5 16 B lt lt Central Bolts a 2 PL B a da Tilt Antenna Plate Ass Hex Nut 5 16 UNC ae Grease 2 PL Joint Lock Bolt must be fastened only when the Dish Antenna Base is in 0 deg Position Elevation Adjustment Bolt 5 16 Notes Notes A At any time kee Joint Lock Bolt Elevation Adjustment B Center the Azimuth Lock Bolts in slot 4 PL j olt in parase to the pole Hex Head Screw Adjustment Bolts must at all time Use tightening torque of 4 Nm on Central Bolts 2 PL grea 5 16 x5 8 UNC After fine adjustment use tightening torque of 4 Nm on Azimuth e Lock Bolts 4PL and 9 Nm on Nut of Elevation Lock Bolts 2PL Tool required 1 2 open end or deep socket wrench Use grease in marked recomended places Tool required 1 2 open end or deep socket wrench SHEET 1 OF 1 4 3 Page 24 EH 1200 Installation Manual 2 8 2 8 1 Connecting the Cables The following Figure shows the ODU interfaces There are two active Ethernet interfaces Eth1 Eth2 These may be optical Fiber SFP or electrical RJ45 physical interfaces configurable 9 1 Electrical Ground Outlet GND 6 Ethernet Cable RJ45 Interface 2 Power Connector Interface PWR 7 Fiber Cable SFP Interface Eth4 3 DVM Probe Interface AUX 8 System LEDs 4 Ethernet Cable RJ45 Interface 9 Reset Button press for more than 8 seconds to restore factory defaults 5 Fiber C
19. able SFP Interface Figure 2 5 EtherHaul Connection Panel Details Power Options To power up the EtherHaul using PoE connect the cable to Eth 1 DC connector connect ONLY the and Figure 2 6 DC Connector Page 25 EH 1200 Installation Manual 2 8 2 DC Power Supply Notes The DC power input range of the ODU is 21 57 VDC The DC supply should be limited to two ampere to avoid surges and possible damage to the ODU For that use limited power supply or circuit breaker fast blow fuse The circuit breaker is the disconnecting device and should be readily accessible e When connecting the ODU to a MAINS DC distribution system use a two ampere circuit breaker to enable the central DC system to isolate the ODU in an emergency case e Use one poly circuit breaker and should connect it on the live voltage or The other poly should be grounded e Connect the circuit breaker to the or live voltage e The DC input is floating so either or can be connected to the GND on the power supply side For the sake of consistency with other systems Siklu recommends that you connect the to the GND e Use atwo wire cable 14 18 AWG to connect the power supply to the ODU On the ODU DC terminal connect only the and wires Do not connect to the ODU s GND input Caution S Disconnect all power cables before service Page 26 EH 1200 Installation Manual 2 8 3 Grounding the Eth
20. al and remote systems of the link The Apply button is available at the bottom of each configuration page one button for both local and remote systems When clicking Apply the configuration changes will be sent to remote system first and then to the local system If multiple parameters changed on the page before clicking Apply all parameters are sent in bulk to the system and then executed locally in order to avoid losing management connection Save Configuration Any configuration change applied should be saved using the Save Configuration button The system has two configuration banks 1 Running Configuration the currently active configuration Every time Apply is clicked the Running Configuration is updated 2 Startup Configuration the configuration the system will come up with after the next reset This configuration may be different than the currently active configuration Running Configuration In order to save the applied configuration changes click Save Configuration so changes will be saved to the startup configuration If changes are not saved to the startup configuration they will be lost the next time the system resets Save Configuration buttons are available for local and remote systems Rollback A safety measure that allows recovering from system configuration changes that caused loss of communication When Rollback is used a timer runs and restarts whenever a management or CLI command is en
21. ble Figure 2 8 All Weather Connecting Cable Shell Assembly Three sets of rubber gasket inserts are provided for different cable diameters e 4 2mm inner diameter for cable diameter 3 5 4 9mm e 5 8mm inner diameter for cable diameter 5 0 6 7mm e 7 9mm inner diameter for cable diameter 6 8 9 0mm For each ODU cable connection perform the following procedure 1 Disassemble a protective shell by unscrewing its parts and carefully removing the rubber gasket insert from the cable inlet portion of the shell Thread the cable connector through the cable inlet portion gl of the shell through the rubber gasket insert and through the connector outlet portion O Connect the cable connector to the ODU interface Screw the connector outlet portion to the ODU firmly by hand do not use tools Insert the rubber gasket insert snugly into the connector outlet portion of the shell Screw the cable inlet portion to the connector outlet portion firmly by hand do not use tools Page 28 EH 1200 Installation Manual 2 8 5 2 8 6 2 8 7 Removing Connectors from the EtherHaul ODU Caution S To avoid accidental damage to the connector always use the following order to remove cable connections from the ODU Unscrew the cable inlet portion of the All Weather shell to release the gasket seal and then remove tension from the cable connector Unscrew the connector outlet portion
22. ched to ODU 9 Elevation fine adjustment screw 16 5 Quick release hooks 10 Elevation screw tension band and pin Figure 2 1 EtherHaul Mounting Assembly Components Prior to mounting unpack the mounting kit package and attach the two unit mounting screws to the front mounting bracket securing them with mounting bolts Assemble the back mounting bracket to the front OQO mounting bracket using one bolt and separate them by about 120 degrees so that the assembly can to be attached to the mounting pole Place the assembly on the mounting pole and rotate the front and back mounting brackets to close the assembly on the pole Replace the unit mounting bolt that was removed Ensure that both front and back mounting brackets are attached evenly to the pole and are completely level Page 21 EH 1200 Installation Manual 5 Use the 13mm open wrench to tighten the nuts on both unit mounting bolts Temporarily tighten the unit mounting bolts at this stage to keep the unit from moving freely 6 By default the ODU is delivered with the quick release plate securely attached in a vertical polarization If necessary change the ODU polarization to match the orientation of the remote ODU by removing the quick release plate changing its orientation and reattaching For ease of reference the markings V vertical and H horizontal are engraved on the back side of the ODU 7 Examine the position scales of both the Azimut
23. de of the radio link Alignment Status R O field indicating that the ODU is currently in Alignment mode by configuration or by inserting DVM probes Transmit Asymmetry Default value is symmetric configuration 50 for Tx and Rx 50tx 50rx For an asymmetric configuration 75 25 or 90 10 Role Page 41 EH 1200 Installation Manual 3 4 3 has to be set the Master unit transmits the higher rate 75tx 25rx or 90tx 10rx and the Slave unit the lower rate 25tx 75rx or 10tx 90rx When selecting asymmetric configuration Role will be set automatically refer to Radio Advanced Settings Click Next to continue or Back to return to previous section Quick Configuration Step 3 Eth Ports Radio Port Enable W Bd Auto Negotiation v Eth Ports Speed Duplex 1000FD E p n P pri WW Eth2 Eth M em Port Type R45 O SFP RJ45 O SFP RI45 SFP Eth2 RI45 VU SFP Figure 3 7 Quick Config Page Step 3 Eth Ports This section allows configuring the following parameters Port status visual display Green port is up Port Type RJ45 or SFP configurable Port Enable checkbox to enable the port Auto Negotiation checkbox to enable auto neg Speed Duplex speed 10 100 or 1000 and duplex half full setting o When Auto Negotiation Enabled R O field indicating the current speed duplex o When Auto Negotiation Disabled allows configu
24. e Precise antenna alignment e Minimal site preparation Security Advanced AES encryption and security Narrow and secure beam width Adaptive Bandwidth Coding and Modulation The EtherHaul family implements hitless errorless adaptive bandwidth coding and modulation adjustment to optimize the over the air transmission and prevent weather related fading from disrupting traffic on the link The EtherHaul can gain up to 21 dB in link budget by dynamically adapting Modulation FEC coding rates and channel bandwidth maintaining the high priority traffic using quality of service advanced mechanism and dropping the traffic according to the QoS priority defined by the user Page 12 EH 1200 Installation Manual 99 99 SOOMbps 52 6 min 4 a Internet email background traffic 99 995 a 2 200 Mbps 26 3 min amp S z Streaming media interactive traffic 99 999 20 Mbps 5 3 min Voice synchronization real time traffic signaling and control Figure 1 1 Hitless Adaptive Bandwidth Coding and Modulation 1 2 Functional Description The EtherHaul is an all outdoor system comprised of the following functional blocks RFIC Siklu s integrated Silicon Germanium SiGe transceiver operating at 57 66GHz EH 600T 71 76GHz EH 1200 EH 1200TL or 71 76 81 86GHz EH 1200F EH 1200FX Modem Baseband ASIC Siklu s modem baseband ASIC includes the modem FEC engines and Synchronous Ethernet support Network Proces
25. e for 2 ft ant Sadi if Raten H d Gas Sh ESS tt Sr Ki geb e N emm e e 3 A N S P Seo EEN A 5 i See K i d d Figure 2 3 EtherHaul ODU for 2ft Antenna Unpack the two foot ODU and remove the protective cap 4 Attach the ODU to the antenna and tighten the four locking bolts Make sure you install the ODU with the required polarization note the polarization arrow on the back of the ODU Figure 2 4 EtherHaul ODU installed on 2ft Antenna 6 Proceed with antenna alignment and ODU setup as described in section 2 10 Page 23 EH 1200 Installation Manual 4 3 INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 3 Azimuth Lock Bolts Step 2 Mast 2 4 5 outer diameter 4PL Bolt 5 16 x1 3 8 UNC Mounting Lock Bolt EH Spring Washer 5 16 5 16 x6 5 UNC 4PL Flat Washer 5 16 d H 6 PL RD43101200C D Step 1 Azimuth Adjustment Bolt 5 16 _ D Grease V 4 Tilt Antenna Plate Ass Holder Bracket 2 PL y Bs Grease Surface Around e ke X the Slot from Both Sides Hex Nut 5 16 UNC S Spring Wahser 5 16 Dish Antenna Base ire 5 16 4 PL lt A d c einen Less e C y Notes i Roughly aim the Mounting Kit Pin perpendicular d to Dish direction Use tightening torque of 9 Nm on Nut of Mounting Lock Bolt 4 PL Tool required 1 2 open end or deep socket wrench Use grease in marked recomended places DETAIL A SCALE 1 1 5 AN eS Hex Nut 5 16 UNC AT Spring
26. e in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful Page 3 EH 1200 Installation Manual interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Note Changes or modifications to this equipment not expressly approved by Siklu LTD or the party responsible for compliance could void the user s authority to operate the equipment Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and wherever applicable are licensed by the appropriate government regulatory authorities Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial liabilities Siklu LTD and i
27. e port Screw the cable inlet portion 0 of the All Weather shell onto the secured top portion taking care not to twist the connecting cable Tighten the bottom portion securely by hand The rubber gasket insert tightens to create a moisture proof seal do not use tools Page 29 EH 1200 Installation Manual 9 Secure the network connection cable into place using a cable tie Ensure that there is sufficient play in the cabling to allow movement of the ODU during final alignment 2 9 System LEDs PWR Power Green Power OK Blink Green Device boot I NA EE T I Red Power Failure eege i Off No Power Green Link Up Blink Green Device boot ETH1 2 Blink Green 1G activity I I I I I I I I I I I I I I I I I I I I I I I I I I I I Off No Link Carrier 2 10 Aligning the Antenna The ODU antenna must be aligned on both local and remote ODUs You must first perform coarse alignment on each ODU followed by fine alignment Accurate alignment of the ODU is critical for achieving the strongest possible receive signal To perform antenna alignment the ODU must be in Alignment mode The ODU has three modes of operation e Alignment Carrier Wave transmission Used for antenna alignment e Adaptive Operational mode used with adaptive bandwidth code and modulation e Static Operational mode used with a fixed modulation profile ODUs ar
28. e shipped from the factory in Adaptive mode The ODU antenna must be aligned on both local and remote ODUs You must first perform coarse alignment on each ODU followed by fine alignment Accurate alignment of the ODU is critical for achieving the strongest possible receive signal To perform antenna alignment the ODU must be in Alignment mode Page 30 EH 1200 Installation Manual The ODU has three modes of operation e Alignment Carrier Wave transmission Used for antenna alignment e Adaptive Operational mode used with adaptive bandwidth code and modulation e Static Operational mode used with a fixed modulation profile ODUs are shipped from the factory in Adaptive mode 2 10 1 Setting the ODU to Alignment Mode Switch the EtherHaul ODUs to Alignment mode by inserting the DVM probes into the AUX Interface sockets The RF LED color indicator turns orange indicating the ODU is in Alignment mode The ODU remains in Alignment mode even if the DVM probes are ejected until the ODU is rebooted 2 10 2 Performing the Alignment Note These instructions are for aligning a one foot antenna For instructions on aligning a two foot antenna refer to Installing the ODU with a Two Foot Antenna These instructions refer to Figure 2 1 EtherHaul Mounting Assembly Components To perform an alignment 1 Verify that the ODU is in Alignment Mode Coarse Alignment Azimuth Only 2 Loosen the unit mounting bolts
29. ease review the individual product s release notes to verify if a specific feature is supported in the product you use Applicable Products and Releases e E Band o EH 1200 minimum SW release 3 5 0 o EH 1200TL minimum SW release 3 5 0 Audience This document assumes a working knowledge of wireless backhaul platforms and their operating environments This document is intended for use by all persons who are involved in planning installing configuring and using the EtherHaul system Conventions The following conventions are used in this document in order to make locating reading and using information easier Special Attention Hint Informs you of a helpful optional activity that may be performed at the current operating stage d Note Provides important and useful information or describes an activity or situation that may or will interrupt normal operation of the EtherHaul system one of its components or the network Page 5 EH 1200 Installation Manual Caution Describes an activity or situation that requires special attention Text Conventions Italicized text is used to reference sections or chapters in this document In many cases references use clickable hypertext links that enable immediate access to referenced objects Document References Command Input Monospace text is used to help delineate command line user input or text displayed in a command window Page 6 EH 1200 Installatio
30. ect the modulation the ODU will be tested at Note that it will take the ODU to stabilize after loopback up to 3 minutes so set the loopback timeout accordingly recommended 600 seconds Mute remote transmitter first to avoid interference with the loopback operation Loopback is done with MAC addresses swap Refer to the Diagnostics chapter of the EtherHaul Operation Administration and Maintenance Manual for detailed detailed description of the system s loopbacks e Mute checkbox to mute the transmitter with timeout in seconds When muted the ODU will not transmit Page 47 EH 1200 Installation Manual 3 5 4 Modulation Table gege mw J sk oh fa Jos pe av ork pb fos Je rr v fos ai fos i v fome ai Jos o pps fe zen bm a h bhs h zen be bk ka bk Modulation Table 74275 Jos h a ps pe oam Jo hp P es fe zas bas fai ab zas base fa hooo fos fas zez be fp of a JI zen e p po ak zez er kk a E zez bas h ho bs e zez base ai ids iio zs es fp ho s pe zez es Ek ak zz les h ho ies gt zas om ais ab 75375 base fa ip fos Je lt gt _ bh Figure 3 12 Radio Page Modulation Table The modulation table presents the available modulation profiles The radio can be configured only to one of the profiles available in the table e CINR Low Lower threshold for stepping down in modulation profile Adaptive Mode e CINR High Upper threshold for stepping up in modulation profile
31. ecting to the ODU Using the Web Based Management 1 Launch an Internet Browser and enter https followed by the ODU s IP address The ODU s default IP address is 192 168 0 1 ar fg gl Oc https 192 168 0 1 pr xX Figure 3 1 Launching the Web Based Management 2 When prompted enter the username and password Default admin and admin e Username Password Magic th The ei Login EH 1200 S N F431077679 Ver 3 5 0 12314 For Java GUI click here Figure 3 2 Entering Username and Password 3 Once loaded the Web Based Management Main page is displayed Quick Config Main Radio Eth Ports System Network Services Advanced Config Statistics Help Logout Ges ee d Status Link Up Magic th The ae Name right_master Name left_slave LOCAL 192 168 0 1 REMOTE Product EH 1200 Product EH 1200 Tx Rx Frequency MHz 74375 74375 RSSI dBm 39 34 38 wy 100 35 100 35 CINR dB 23 Em q1 22 WE q1 4 25 4 25 Mode Adaptive QAM64 410 5 Adaptive QAM64 4 1 0 5 Estimated Throughput Mbps 1000 1000 A SEN 3 2014 09 20 04 03 48 link down eth eth1 Active Alarms 2014 12 22 04 22 58 link down eth eth2 2014 09 20 04 03 48 link d eth eth2 History Log Show Export Clear Show Export Clear User Activity Log Show Export Clear Show Export Clear Save Local Configuration Reset Local Timeout sec Start Rollback
32. ed to carry out such activities Caution The installation and maintenance of the EtherHaul link should only be done by It is the responsibility of the installer to insure that when using the outdoor antenna kits in the United States or where FCC rules apply only those antennas certified with the product are used The use of any antenna other S than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15 204 Preparing the Site Carefully select and prepare each EtherHaul ODU site to make device installation and configuration as simple and trouble free as possible During site selection and preparation always consider the long term needs of both your network and your applications Page 17 EH 1200 Installation Manual 2 1 1 Physical and Environmental Requirements Each EtherHaul ODU site should adhere to the following requirements e There must be a clear unobstructed line of sight between ODU e The EtherHaul ODU should be mounted on a fixed stable permanent structure A reinforced steel mounting pole is required with a diameter measuring from 2 4 inches 1ft antenna or 2 4 5 inches 2ft antenna Caution Doing so may result in poor service or equipment damage S Do not mount the EtherHaul device on a structure that is temporary or easily moved You must mount the EtherHaul ODU in a site that is easily accessible to authorized personnel and only authorized perso
33. equirements that are detailed in the accompanying checklist Physical Installation Verification This inspection verifies the physical installation of the ODU in accordance with the EtherHaul s installation procedure and requirements 1 Pole mount installation 2 ODU installation 3 Weatherproofing the cables 4 Cables installation 5 Grounding RF Link Test This inspection verifies the RF link status 1 RFLED is green 2 Management CLI indication RF Operational Up 3 Receive Signal Strength Indication RSSI achieved in Alignment mode is within 4dB of the expected value 4 Carrier to Interference Noise Ratio CINR is 19 or higher 5 Highest modulation achieved 6 Link configuration is in accordance with plan requirements Link Errors Test This inspection verifies frame loss free operation of the radio link Page 50 EH 1200 Installation Manual 1 No ARQ losses on the RF Statistics counters 4 1 4 Ethernet Services Test This inspection verifies correct Ethernet services flow and error free operation 1 Connect PCs on both ends of the link and use software based utilities to test for packet loss 2 If available connect a packet analyzer to the GbE port and verify that no packets are lost 4 1 5 Management Verification This inspection verifies proper management of the link 1 Verify correct management CLI connection to both local and remote ODUs 2 Verify management access from
34. erHaul 1 Connect one end of the grounding cable to the ground outlet on the left side of the ODU using the grounding cable lug 2 Tighten the lug securely in place 3 Connect the opposite end of the grounding cable to the earth connection typically located on the mounting pole If the earth connection is out of reach of the grounding cable install an alternative cable To make a protective earth connection use the grounding point located on the System ODU using a minimum amount of 16AWG grounding cable or according to local electrical code It is recommended to use Lightning Surge Protector on every Ethernet cable to protect the indoor networking equipment The Lightning Surge Arrestor should be installed indoor next to the cable s point of entry and should be properly grounded m E em Grounded te pote Wake sure lo matkine point te DN 1 assure good ground connect ty I Shielded Ethernet Cable Shielded Ethernet Cable From roof Verify grounding continulty between outdoor and indoor l graria Figure 2 7 Grounding Scheme Page 27 EH 1200 Installation Manual 2 8 4 Preparing the Cables Before inserting a cable connector into the ODU you must first enclose the cable connector in a protective All Weather shell Three sets of All Weather shells are provided with the ODU for the ODU interfaces 1 Cable Inlet Portion 3 Connector Outlet Portion 2 Rubber Gasket Insert 4 Ethernet Ca
35. es OAM and Resiliency e Synchronization Synchronous Ethernet ITU T G 8261 and IEE 1588TC Encryption Vlan configuration and Provider Bridge settings capabilities are enabled by default and do not require a license The software licenses are serial number dependent 1 5 Management You can manage an EtherHaul system using a Web Based Element Management System Web EMS or a Command Line Interface CLI The CLI is compatible with SNMP Advanced network features must be managed using the CLI Page 15 EH 1200 Installation Manual The EtherHaul system features a wide range of built in indicators and diagnostic tools for advanced OAM functionality The system is designed to enable quick evaluation identification and resolution of operating faults Page 16 EH 1200 Installation Manual 2 2 1 Installing the EtherHaul System This chapter describes how to install and perform the basic setup for EtherHaul outdoor unit ODU in an EtherHaul wireless network including Preparing the Site EtherHaul Package Content Unpacking the EtherHaul Required Tools Preparing for Installation Mounting the EtherHaul Installing the ODU with a Two Foot Antenna Connecting the Cables System LEDs Aligning the Antenna Link Up Verification The installation of the EtherHaul system is followed by initial system setup that will be described in the next chapter Caution service personnel who are properly trained and certifi
36. h adjustment lock bolts and the elevation adjustment lock bolts found on the front mounting bracket and ensure that they are positioned at O degrees in the middle of the scale 8 Position the quick release hooks onto the top elevation adjustment lock bolt and carefully set the ODU in place on the front mounting bracket and slide it firmly inwards Mount the ODU by attaching the interior quick release hook A in place before attaching the exterior hook B The interior hook is the one located farthest from the tightening nut as shown below Hint A Interior Quick Release Hook B Exterior Quick Release Hook C Elevation Position Slot Figure 2 2 Quick Release Hooks 9 Unlock the Azimuth adjustment lock bolts and the elevation adjustment lock bolts 10 Stretch the elevation screw tension band slightly and connect it to its mating tension pin located on the quick release plate Page 22 EH 1200 Installation Manual 2 1 Installing the ODU with a Two Foot Antenna This appendix presents the installation instructions of EtherHaul 1200 ODU with a two foot antenna 1 Install the two foot antenna according to the mounting diagram on the next page Antenna mounting kit installation instructions are also available inside the mounting kit package 2 Remove the protective tape on the antenna feed The two foot ODU is shipped with External ODU adapter attached Ds Outdoor Unit Adaptor Plat
37. herHaul Package Content An EtherHaul link consists of two ODUs and two mounting assemblies The EtherHaul packages include the following components EtherHaul 1200 ODU EtherHaul 1200 ODU with 1 1ft integrated antenna Connecting cable All 3 Weather shells Unit grounding cable 90 1 cm DC cable terminal block 1 connector EtherHaul 1200 mounting assembly EtherHaul 1200 mounting 1 assembly 2 3 Unpacking the EtherHaul The EtherHaul package content should be examined carefully before installation When you unpack the components of the EtherHaul it is important to use care so as to avoid damaging or scratching the antenna radome e Do not touch the radome when unpacking the ODU e Do not rest the ODU face down or touch the radome It is crucial to prevent contact between the radome and other objects Page 19 EH 1200 Installation Manual 2 4 2 5 Required Tools Ensure that you have the following tools with you when performing an EtherHaul installation e Standard handheld digital voltage meter DVM with probes e Standard open end wrench 13 millimeter e 8mm Allen key for ODU installation with 2ft antenna e Philips screwdriver medium size head for grounding connection Flat head screwdriver small size 2mm head for DC connector e Cable ties for securing network and optional power cables e Cutter e Cable labeling Preparing for Installation The expected receive signal strength should be calc
38. lability and services The following are some of the main features of the EtherHaul availability of features depends on platform All Outdoor Packet Radio e Operates in the light licensed 71 76 GHz E Band Upto 1 Gbps throughput e Asymmetric capacity configuration e High gain narrow beam width directional antenna e Low latency Highest Spectral Efficiency 500 MHz channel bandwidth e Advanced hitless errorless Adaptive Bandwidth Coding and Modulation ABCM for a large dynamic range e Configurable center frequency across the entire band Page 11 EH 1200 Installation Manual Carrier Ethernet Inside e Integrated Gigabit Ethernet switch e Advanced bandwidth aware QoS capabilities MEF compliant services and QoS Advanced service management OAM and SLA assurance support SyncE and optimized transport of IEEE 1588 Ring mesh and daisy chain topologies for carrier grade availability and resiliency Standard based for seamless integration into existing networks and multi vendor interoperability e Multi vendor interoperability approved Carrier Grade e CLI SNMP and web based local and remote management Extremely high reliability with very high MTBF e Designed for ultra low MTTR without the need for antenna realignment Green Design e Zero footprint all outdoor extremely light weight e low power consumption e IEEE 802 3at complaint Power over Ethernet Quick and Easy Installation e Rapid and flexible deployment
39. n Manual TABLE OF CONTENTS 1 Introduction to the EtherHaul System cccccssssesssseeseeseeseeneesenneeseaes 10 EST EN e Oe EE 11 EE MINS MO Males Cr MOM EE 13 Lo Feed 14 LA Ee EE 15 E Ee EE 15 2 installing the EtherHaul System ssssssssssrsssrssnnsrsesnrsnnrrnnn rn ARR RA RAR AREA ARR RA A gt 17 Se EE 17 2 1 1 Physical and Environmental Reouements 18 SS ME ee ICM EE 18 2 2 JBMherhal e OMe tl sei E N 19 Zor in E THC TAN Cr EE 19 De e E E 20 20 Preparing tor InstallanOn E 20 20 ue 21 2 7 Installing the ODU with a Two Foot Antenna ra 23 2 05 COMME ine LINC EE 25 GN POWT EE 25 Ze MC Power ee 26 Zod Ground EE 21 23 Preparite te D 28 2 8 5 Removing Connectors from the EtherHaul OD 29 2 000 Connectme DEO EE 29 28 7 Connectimo Other tere ee gege geed eege 29 2D SVEM LED inert eC E rere ee 30 DAO JX oming Che AMC EE 30 2 10 Setting the ODU to Alenment Mode nacauintiatetintiotatintiniatinianan 31 2 AO 2 Perlormine the Et E 31 Ss degkeet 32 3 Performing Basic Setup Using the Web Based Management 34 3 1 Connecting to the ODU Using the Web Based Management ssseosssrossersssrossnrr gt 35 ANP AMINE EE 36 55 EE 38 Dials ND PLN EE 38 D2 Save COM OUA O ecseri rera a 38 Page 7 EH 1200 Installation Manual Ds ROMA EE 38 P WC oS eer reer reer Tee rn te te ee nee een eee ee eee ee eee ee eee 39 Bio COPY Le 39 3 4 Quick
40. nnel Operating temperature between 45 and 55 C Relative humidity 0 to 100 Maximum altitude 4 500m Ingress Protection rating IP67 2 1 2 Cabling Requirements Ensure that your power connection cable matches the EtherHaul power connector pin outs Install the EtherHaul ODU where network connections and optional power cabling are ready for operation and easily accessible All cabling connected to the ODU should be outdoor grade with UV protection Use a two wire cable 14 18 AWG to connect the power supply to the ODU You should use shielded outdoor Cat5e cables terminated with metallic RJ45 connectors In order to protect indoor equipment you must install surge protection circuits on all copper cables on their entrance to the building Install the EtherHaul ODU in a location where proper electrical outdoor grounding is readily available Typically the grounding connection is attached directly to the mounting pole If not already present then suitable structure to earth grounding connections must be created before installation Ground the ODU using a minimum quantity of 16AWG grounding cable or according to local electrical code Page 18 EH 1200 Installation Manual Improper electrical grounding can result in excessive electromagnetic interference or Caution electrical discharge Siklu will not be held responsible for any malfunction or damage in the event that the ODU is not properly grounded 2 2 Et
41. ollowing parameters Channel Bandwidth MHz 250 or SOOMHz default is SOOMHz Note 250MHz support depends on product s specs Tx Frequency MHz transmit frequency Rx Frequency MHz R O field updated based on Tx frequency Tx Power dBm ODU s transmit power Default is the max power based on product s specs Minimum configurable Tx power is 35dBm note that actual minimum Tx power is based on product s specs Note Adjust Tx Power so the RSSI at the remote end will not exceed 35dBm overload threshold The Tx power value sets the transmit power for the highest modulation profile In case lower modulation profile s has higher max Tx power based on product s specs the Tx power will be increased automatically without indication in RF configuration menu Mode operational mode of the link o Alignment Carrier Wave transmission Used for antenna alignment No data over the radio link Note the radio link When exiting Alignment mode perform system reset to allow proper operation of o Static Fixed modulation profile If you select Static you must select from a list of pre configured modulation profiles in the Modulation field o Adaptive Adaptive Bandwidth Code and Modulation The ODU will work on the highest modulation profile based on the CINR values of the both sides and will present the current modulation profile Adaptive mode is the normal and recommended mo
42. outing capabilities as networks evolve to flat IP topologies The EtherHaul products features advanced adaptive modulation bandwidth and coding allowing operators to maintain prioritize and verify QoS in all weather conditions while achieving maximum up to 99 999 link availability for prioritized services such as voice signaling and Sync Offering easy and low cost all outdoor installation and a small form factor the EtherHaul products are also environmentally friendly boasting a small system and antenna footprint with especially low power consumption The EtherHaul systems are High capacity Gigabit Ethernet backhaul with advanced networking capabilities at the lowest TCO in the industry EtherHaul enables mobile operators to profitably and reliably provide data intensive services Provided by Siklu the pioneer in silicon based mm waves backhaul systems EtherHaul systems are the perfect choice for future proof investment Main Features Siklu s EtherHaul wireless backhaul radio link operates in the new V band and E band spectrum which provides clear technological and economic advantages over the existing lower frequency bands Taking advantage of the new spectrum the EtherHaul enables easy migration to support Gigabit throughput enabling operators to enhance bandwidth capacity on a pay as you grow basis Supporting point to point daisy chain ring and mesh configurations the EtherHaul system offers carrier class avai
43. ring the spoeed duplex 1000 speed is available Click Next to continue or Back to return to previous section R O field indicating the current speed duplex note that for SFP ports only Page 42 EH 1200 Installation Manual 3 4 4 Quick Configuration Step 4 Network Quick Config Main Radio Eth Ports System Network Services Advanced Config Statistics Help LOCAL 192 168 0 1 sger SE REMOTE Name EH 1200F Status Link Up Name EH 1200F CA EE IP Address Type IP Address Prefix length VLAN Type IP Address Prefix length VLAN Radio 1 Static vl 192 168 0 1 24 0 1 Static v 192 168 0 1 24 0 Eth Ports 2 static Te 10 10 10 1 24 0 2 static Tel 10 10 10 2 24 0 Network Add IPv4 Add IPv6 Add IPv4 Add IPv6 Ka Default Gateway IP Address 10 10 10 250 IP Address 10 10 10 250 IPv6 Address IPv6 Address SNMP Managers Security 8 A IP Address UDP Port SNMP Ver Engin ID IP Address UDP Port Security Name SNMP Ver Engin ID Add Add Figure 3 8 Quick Config Page Step 4 Network This section allows configuring the following parameters e P Address The EtherHaul supports up to four IP addresses that can be associated with different VLANS IPv4 or IPv6 can be configured IP addresses may also be acquired by
44. rr enn ns 23 Figure 2 5 EtherHaul Connection Panel Details 25 Figure 2 0 DE EE ee EEN EEN ENEE EENS ENNEN ENN 25 tere T Grounding 5 CHC TAG enerne ie etic case aia die ta ate Ra es NONE Ee 21 Figure 2 8 All Weather Connecting Cable Shell Assembly ussmossssssssersrrsrrrrrrrrerrerrrerrerrrrrerrr gt 28 Figure 3 1 Launching the Web Based Management 35 Figure 3 2 Entering Username and Password s ssssesessserrsesserrrrrrrrrrerrrrerrrrrrrrrrrrrrrrrrrrrrrrrrr rerna 35 Figure 3 3 Web Based Management Main Page 35 Fieure 3 4 Copy Lo Remot e ICON aiisie vases ee eee 39 Fisure 3 Quick Conte Pace Step I Syste sasse skena sa nn NRA 40 Figure 3 6 Quick Config Page Step 2 Radio 40 Figure 3 7 Quick Confis Page Step 3 Emi Ett degen 42 Figure 3 8 Quick Config Page Step 4 Network 43 Fiure 329 Radio EE EE AA Figure 3 10 Radio Pace gees 46 Pioure 3211 Radio Pace Maintenance een 47 Figure 3 12 Radio Page Modulation Table 48 Page 9 EH 1200 Installation Manual Introduction to the EtherHaul System This chapter provides a brief overview of the EtherHaul product line The EtherHaul 1200 product line delivers carrier grade wireless point to point gigabit Ethernet services utilizing the light licensed 71 76Hz E band spectrum TDD The EtherHaul is based on Siklu s revolutionary integrated silicon technology which results in a highly reliable zero footprint and low cost radio The EtherHaul offers Gigabit throughput MEF compliant
45. sor the networking engine is the heart of the high speed bridge router function The engine receives packets from Ethernet interfaces the modem and CPU It is responsible for proper forwarding between these all interfaces Interfaces The network interface consists of 2 4 integrated 100 1000 Ethernet ports depends on the product type Host processor CPU the host processor controls the system responsible for the control plane and the antenna alignment Antenna Siklu s self designed 1ft innovative antenna as well as 2ft antenna option for longer range higher availability Page 13 EH 1200 Installation Manual 1 3 Modem amp Packet Proc RFIC Network Processor RF Controller PoE me Baseband ASIC Figure 1 2 EH 1200 TDD Functional Block Diagram Technical Specifications For detailed technical specifications please refer to the datasheet For detailed supported features list please refer to the product s release notes EtherHaul 1200F Technology and frequency e TDD 71 76 81 86GHz e Hitless adaptive bandwidth coding and modulation boosting system Adaptive modulation gain by 25dB Over the air throughput e Upto 1000Mbps Aggregated duplex Typical link distance e Upto 4500m maximum 7000m e 2xGE 2xCopper or SFP ports combo ports ge e Integrated 1ft 31cm Cassegrain reflector 43dBi antenna gain ntenna e External 2ft 65cm Cassegrain reflector 50d
46. ssing the ODU Reset Button or alternatively disconnect reconnect the power This action will returns the ODU to Adaptive Mode ODU s default operational mode Following this action and after the ODU has finished rebooting the RF Page 32 EH 1200 Installation Manual LED color indicator on both ODUs will turn Green indicating that the radio link is up The EtherHaul link can now pass traffic and management between the ports and over the radio link Use the Web based management or Command Line Interface for radio link configuration and monitoring Page 33 EH 1200 Installation Manual Performing Basic Setup Using the Web Based Management This chapter describes how to perform basic setup using the web based management The scope of this installation manual is basic setup and monitoring of the radio link e For full configuration and maintenance procedures refer to the EtherHaul Operation Administration and Maintenance Manual e The EtherHaul Operation Administration and Maintenance Manual also details the configuration monitoring and maintenance procedures using the Command Line Interface This chapter includes the following topics e Connecting to the ODU using the Web Based Management e Main Page e General Configuration Commands e Quick Configuration Wizard e Radio Page e Default Bridge Configuration e Applying and Saving Configuration Changes Page 34 EH 1200 Installation Manual 3 1 Conn
47. tered In the event that no command is entered within the timeout period the system automatically resets and comes up with the saved startup configuration A Rollback timeout is especially recommended when configuring remote elements that are being managed over the link Rollback is activated for both local and remote systems Page 38 EH 1200 Installation Manual 3 3 4 Reset Separate buttons for local and remote reset The system will reset and come up after initialization 120 seconds Note that any unsaved changes will be lost 3 3 5 Copy To Remote You can find the Copy To Remote button next to some configuration parameters or sections This function copies configuration to remote system based on the changes on the local system Figure 3 4 Copy To Remote icon Matching configuration may be of two types Identical configuration exactly same configuration will be copied from the local to remote system It can be found for parameters that normally requires identical configuration for both local and remote units For example Encryption configuration Matching configuration for parameters that require matching but opposite configuration Page 39 EH 1200 Installation Manual 3 4 3 4 1 3 4 2 Quick Configuration Wizard Use the Quick Configuration wizard to configure the basic system parameters It holds the basic minimal configuration required to start using the link The Quick Configuration
48. ts resellers or distributors are not liable for injury damage or violation of regulations associated with the installation of outdoor units or antennas Caution Prudence Les unit s ext rieures et les antennes doivent tre install s que par des professionnels exp riment s d installation qui sont familiers avec les norms locales et les codes de s curit et si applicable sont agr es par les autorit s gouvernementales de r glementation comp tents Ne pas le faire peut annuler la garantie du produit et peuvent exposer l utilisateur final ou le fournisseur de services d obligations juridiques et financiers Revendeurs ou distributeurs de ces quipements ne sont pas responsables des blessures des dommages ou violation des r glements li s a l installation des unit s ext rieures ou des antennes L installateur doit configurer le niveau de puissance de sortie des antennes conform ment aux r glementations nationales et le type d antenne Page 4 EH 1200 Installation Manual About this Document This document is the Installation Manual for the EtherHaul 1200F wireless Link It provides product overview and details the installation and initial setup For instructions how to use the product s features refer to the EtherHaul Operation Administration and Maintenance Manual Features and functionality described in this document may be available for specific Note product models or starting from specific SW version A Pl
49. ulated prior to installing the link for each antenna ODU read from the DVM prior to installation based on the network link budget Calculating the expected RSSI RSSI Pix Gant1 es LES eg Attatm Gant2 Where e Pi ODU s Tx Power typically 5dBm e Ganti1 Gain of antenna 1 typically 35dBi e Gant2 Gain of antenna 2 typically 35dBi LFS Loss of Free Space 92 45 20 Log Dxm Feuz D Link distance in Km F Frequency in GHz Attatm Attenuation due to Atmospheric Gases dB Km For E band links the Attenuation due to Atmospheric Gases is typically 0 5dB Km For V band links the Attenuation due to Atmospheric Gases is significantly higher up to 15dB Km and depends on the specific channel used and the exact geographical location Refer to EtherHaul Link Budget Calculator for on line calculation of expected availability and expected RSSI Page 20 EH 1200 Installation Manual 2 6 Note Mounting the EtherHaul e These instructions are for mounting a system with a one foot antenna For instructions on mounting the EtherHaul 1200 with a two foot antenna refer to Installing the ODU with a Two Foot Antenna e Torque level for tightening the nuts and bolts is 8nm 1 Unit mounting screws and bolts 6 Azimuth adjustment lock bolts 2 Back mounting bracket 7 Elevation adjustment lock bolts 3 Front mounting bracket 8 Azimuth fine adjustment screw 8 4 Quick release plate atta
50. ved tighten both Azimuth adjustment lock bolts Align the fine elevation axis Use the hexagonal wrench to adjust the elevation fine adjustment screw Be sure to sweep the complete range of the elevation in order to determine the maximum received signal strength position When the optimum axis is achieved tighten both elevation adjustment lock bolts el Perform steps 6 and 7 for the remote ODU Repeat steps 6 and 7 for the local ODU Use the DVM to verify maximum received signal strength on both local and remote ODUs For best performance measured RSSI should be within 4 dB of the calculated value Once the optimum position has been achieved for the ODU pair tighten the Azimuth adjustment lock bolts on one ODU torque of 8 nM being very careful not to move the ODU while tightening Tightening the Azimuth adjustment lock bolts will tilt the ODU so realign the elevation again for optimum position Once the optimum position has been achieved for the ODU pair tighten the elevation adjustment lock bolts on the ODU torque of 8 nM being very careful not to move the ODU when tightening Repeat steps 11 through 13 for the second ODU Use the DVM to verify that the received signal strength has not changed on either the local or the remote ODU after final tightening of the brackets Antenna alignment is now complete Link Up Verification 1 2 Disconnect the DVM probes Reboot both ODUs by shortly pre
51. wizard should be used for the initial system setup after installation For monitoring and advanced configuration please refer to the dedicated configuration pages of the Web Based Management To access the Quick Configuration wizard go to the Quick Config page Quick Configuration Step 1 System Quick Config Main Radio Eth Ports System Network Services Advanced Config Statistics Help LOCAL 192 168 0 1 eem BE REMOTE Name EH 1200F Status Link Up Name EH 1200F v Se Product Name Site_A Site_B stem Date amp Time Date 2014 06 14 Time 15 02 36 Date 2014 06 14 x Time 15 00 42 Figure 3 5 Quick Config Page Step 1 System The first section allows configuring the following parameters e Name you can give a name for each system e Date YYYY MM DD Time HH MM SS Click Next to continue Quick Configuration Step 2 Radio Channel CA Se Bandwidth MHz 200 a 500 Lv Tx Frequency 74375 MHz Ei Copy to Remote gt gt 74375 E 5 5 wo Radio Tx Power dBm Alignment Status Inactive Inactive QAM64 4 10 5 QAM64 4 1 0 5 Moce Adaptive Alignment Static Copy to Remote gt gt Adaptive Alignment Static i it ian 50TX 50RX_ y Copy to Remote gt gt 50TX 50RX y Back Next Figure 3 6 Quick Config Page Step 2 Radio Page 40 EH 1200 Installation Manual This section allows configuring the f