Home

Installation and Operating Instructions

image

Contents

1. 49 341 301 0413 Fax 1 630 851 7744 Interstate Offices E mail akrenz daveyeurope com Website daveyusa com Sydney Brisbane Adelaide E mail sales daveyusa com Perth Townsville 400278 3 indd 1 P N 400278 4 Supersedes P N 400278 3 DEPEND ON DAVEY WATER PRODUCTS W SN Installation and Operating Instructions WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the Installation Instructions provided in this manual Please pass these instructions on to the operator of this equipment 2007 11 08 12 00 23 Prior to using this pump you must ensure that e The pump is installed in a safe and dry environment e The pump enclosure has adequate drainage in the event of leakage e Any transport plugs are removed e The pipe work is correctly sealed and supported e The pump is primed correctly e The power supply is correctly connected e All steps have been taken for safe operation Appropriate details for all of these items are contained in the following Installation and Operating Instructions Read these in their entirety before switching on this pump If you are uncertain as to any of these Installation and Operating Instructions please contact your Davey dealer or the appropria
2. is the installer s owners responsibility to locate the pump such that the nameplate can be easily read and it can readily accessed for service Weather Protection It is recommended that the pump is protected from the weather 400278 3 indd 2 POWER CONNECTIONS AND WIRING MUST BE CARRIED OUT BY AN AUTHORISED ELECTRICIAN DANGER Hazardous suction Do not block water entry into filtration system with any part of your body as the pressure can trap hair or body parts causing severe injury or death Do not block suction Turn off pump immediately if someone becomes trapped Caution Do not add chemicals directly to the pool skimmer Adding undiluted chemicals may damage pump and filter and void warranty The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Routine Maintenance tasks to maximise the life of your pool equipment amp personal safety use this checklist once a week Turn pump off first a Make sure that any pressure gauges are in working condition and the operating pressure is within limits as specified on the product b Make sure that each suction inlet and main drain has a cover that is securely attached and in safe working condition Make sure that all skimmer covers are securely attached and in safe working condition These should be replaced every 3 to 4 years Remove any
3. This DAVEY WATER PRODUCTS GUARANTEE FOR AUSTRALIA amp NEW ZEALAND Davey product is guaranteed to be free of material or manufacturing defects at the time of original purchase Should any part fail as a result of such defects within three years of original purchase the product will be repaired free of charge Davey Water Products Pty Ltd _ International Member of the GUD Group ABN 18 066 327 517 TERMS AND CONDITIONS This guarantee applies to all states and territories of Australia and New Zealand only and is subject to the provisions of the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and the Consumers Guarantee Act 1993 NZ as applicable The guarantee period commences on the date of original purchase of the equipment Evidence of this date of original purchase must be provided when claiming repairs under guarantee It is recommended you retain all receipts in a safe place This guarantee covers parts and workshop labour only Goods should be forwarded with proof of date of original purchase to an Authorised Davey Service Centre freight paid Any travel and removal reinstalling charges for goods repaired infield will be to the owners account Guarantee may be denied on goods not readily accessible for service personnel or mounted on exterior walls above single storey level This guarantee is subject to due compliance by the original purchaser with all directions and conditions se
4. e necessary to re prime the pump This should be carried out as described above Never run pump dry Running the pump with no water may damage the mechanical seals causing leakage and flooding Dry running damage and associated damage is not covered under warranty Silensor incorporates dry run protection which will need to be re set by turning off the power supply reducing potential damage Emptying the Strainer Basket The strainer basket should be inspected frequently through the transparent lid and emptied when a build up of rubbish is evident The directions below should be followed 1 Switch off pump Close all valves in pipework Unscrew the strainer basket lid anti clockwise and remove Remove the strainer basket by lifting upwards from its housing Empty the trapped refuse from the basket Hose out with water if necessary Check the strainer basket for cracks replace the strainer basket in the pump if OK AARWN 400278 3 indd 4 Emptying the Strainer Basket continued 7 Replace the lid and ensure that it seals on the large rubber oring Firm hand tightness only is required The oring amp thread can be lubricated with Hydra slip or equivalent products 8 Open all valves in pipework Failure to undertake regular maintenance may cause damage not covered by warranty Trouble Shooting If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter r
5. equires backwashing or it is blocked Refer to the relevant section in the Filter Manual 2 The pump is not primed Re prime as per instruction in Starting the pump 3 There are air leaks in the suction piping Check all piping and eliminate leaks also check for a loose strainer basket lid Air bubbles in the water flowing back to the pool would indicate a leak in the suction to the pump allowing air to enter the pipework 4 Aleaking pump shaft seal may also prevent operating Evidence of this would be water on the ground under the pump 5 The pump is not able to get water from the pool Check that the valves to the pump are fully open and that the pool water level is up to the skimmer box 6 Blockage in the piping or pump Remove the strainer basket and check for any blockage to the pump impeller entry Check the skimmer box for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 240 volt only check the power point by plugging in a portable appliance to ensure power is available Also check fuses and the main power supply switch 2 Automatic overload is tripped following an overheating period The pump has an in built thermal overload which will re set after the motor has cooled and the power supply has been re set turn off and back on Determine the cause of the overload tripping and rectify 3 Blockage is preventing the pump from rotating 4 Motor is burnt out burni
6. ge piping from the pump outlet should be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required Starting the Pump To operate efficiently and prevent pump damage there must be a free flow of water to and from the pump Before starting ensure that all pipework is correctly sealed the pool spa water level is at the correct height that all appropriate valves are open and there is nothing preventing the flow of water through the system 1 First prime the pump by removing the strainer basket lid and filling the strainer basket area with water Replace the lid ensuring that it seals on the large oring Connect to the power supply and switch on Allow the pump to run so that any air trapped may be expelled 4 If prime is not established within approximately two minutes as evidenced by a strong flow of water switch off the pump and repeat the procedure Continued evidence of air under the strainer basket lid indicates an air leak in the suction piping which should be rectified to avoid pump damage oN Pump Operation For optimum pump performance the strainer basket housing should always be full of water and free from air bubbles The water level of the pool should always be maintained to at least halfway up the skimmer box ensuring water is in the pump at all times From time to time it may b
7. n and the pump inlet pipework 3 Remove the discharge amp suction barrel unions taking care not to lose the orings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your Silensor be certain to quote the model number from the nameplate located on motor Water Quality Maintaining balanced water chemistry is important to the life of your pool pump This pump is designed to be used with Pool amp Spa water balanced in accordance with Langlier Saturation Index with a pH level of between 7 2 and 7 8 and is regularly treated with a chlorine sanitising agent with the level not exceeding 3000PPM Please consult your local pool shop regularly to have your water tested 400278 3 indd 3 Power Connection Davey Silensors are suitable for connection to a nominal 240 volt 50Hz power supply and are equipped with a flex lead and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided by an electrician Extension cords are unsafe around pools and should be avoided If the supply cord of this product is damaged it must be replaced by the dealer or manufacturer with genuine Davey spares Davey Water Products recommends that all installations are fitted with earth leakage or residual current protection devices CAUTION In the interest of safety we advise that all brands and type
8. ng smell is evident Replacement is required If you are unable to resolve any installation or operation difficulties with your Silensor contact the supplier from whom the pump was purchased or your nearest Authorised Davey Pool Equipment Service Centre If any further assistance is required contact the Davey Customer Service Centre at the address indicated in this manual 2007 11 08 12 00 25
9. obstructions or debris from the main drain cover Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at least once a week Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are clean and that all wiring and electrical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered Check water balance and sanitiser levels at your local pool shop WARNING Pump suction is hazardous and can trap and drown or disembowel bathers Do not block suction Do not use or operate swimming pools spas or spa baths if a suction cover is broken missing or loose Two suction covers and inlets must be provided into every pump to avoid suction entrapment After Sales Service For professional after sales service or repair contact your Davey Dealer For assistance in locating your nearest dealer contact the Davey Customer Centre on 1300 367 866 Visit Davey Water Products on line for further information davey com au K 2007 11 08 12 00 24 Removal of the Pump from Pipework Should it be necessary to remove the pump follow these instructions 1 Switch off the power and remove the plug from the power source NOTE If the pump is wired into a time clock or another automatic control the wiring should be removed by a qualified electrician 2 Close the water valves on the pool retur
10. ry Nothing in this guarantee is intended to have the effect of contracting out of the provisions of the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and Consumers Guarantee Act 1993 NZ except to the extent permitted by the various Acts and this guarantee is to be modified to the extent necessary to give effect to that intention Davey may be collecting personal information from you in order to provide you with a service Davey Water Products Pty Ltd promises only to use this information in accordance with the Provisions of the Privacy Act 1988 Cth and the Privacy Policy of Davey Water Products Pty Ltd which is available at davey com au Davey and Silensor are registered trademarks of Davey Water Products Pty Ltd Davey Water Products Pty Ltd 2006 New Zealand 7 Rockridge Avenue Penrose Auckland 1330 6 Lakeview Drive Scoresby Australia 3179 Head Office and Manufacturing Ph 61 3 9730 9121 Ph 64 9 570 9135 6 Lakeview Drive Fax 61 3 9753 4248 Fax 64 9 527 7654 Scoresby Australia 3179 E mail export davey com au Website daveynz co nz Ph 61 3 9730 9222 E mail sales daveynz co nz Fax 61 3 9753 4100 Website davey com au Germany USA Davey Pumps Inc Customer Service Centre Kantstrasse 53 1005 N Commons Drive Ph 1300 367 866 04275 Leipzig Aurora Illinois 60504 Fax 1300 369 119 Ph 49 341 301 0412 Ph 1 630 898 6976 E mail sales davey com au Fax
11. s of pool pumps must be installed in accordance with AS3000 wiring rules or equivalent In accordance with AS 3350 2 41 we are obliged to inform you that this pump is not to be used by children or infirm persons and must not be used as a toy by children If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and the skimmer box and in the return pipe from the filter to the pool The fittings on this product are constructed of ABS Some PVC jointing compounds are incompatible with ABS Check compound suitability before use Warning Ensure that an electrical isolation switch is located with easy access so that the pump can be switched off in an emergency Pipe Connection A set of barrel unions are provided for connecting to the piping from the pool The pumps are designed to accept the following PVC pipes by fitting the pipe to either the inside or the outside of the union tail Inlet PVC Outlet PVC Position SLS100 300 40mm pipe ID 40mm ID or 50mm fitting OD 50mm fitting OD SLL150 200 40mm pipe ID 40mm pipe ID or 50mm fitting OD 50mm fitting OD or 50mm pipe ID 50mm pipe ID SLL300 400 50mm pipe ID 50mm pipe ID 2007 11 08 12 00 25 Pipe Connection contined The use of any pipe smaller than those specified above is not recommended Suction piping should be free from all air leaks and any humps and hollows which cause suction difficulties The dischar
12. t out in the Installation and Operating Instructions Failure to comply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation chemical or additives in the water inadequate protection against freezing rain or other adverse weather conditions corrosive or abrasive water lightning or high voltage spikes or through unauthorised persons attempting repairs are not covered under guarantee The product must only be connected to the voltage shown on the nameplate Without limiting the original purchaser s entitlements under the Trade Practices Act Aust the Goods amp Consumer Protection Legislation of the various Australian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from the product or any defect Where the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and the Consumers Guarantee Act 1993 NZ does not apply Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever suffered by the purchaser arising directly or indirectly from the product or any defect and the purchaser shall indemnify Davey against any claim by any other person whatsoever in respect of any such loss damage or inju
13. te Davey office as listed on the back of this document Your Davey Silensor Congratulations on your purchase of a quality product from the Davey range of Pool and Spa Equipment You are assured of many years of reliable and efficient performance from your Davey Silensor backed by Davey s three year guarantee Davey Silensors have been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent They should not be used for any other purpose without first consulting your Davey Dealer or the Davey Customer Service Centre Davey design and build its own electric motors especially for its pumps The matched motor and pumping end are designed to provide the quietest operation while delivering maximum water flow Davey s innovative water cooled motor incorporates manual overload protection with a built in automatic thermostat designed to protect the motor from overheating This protection will also prevent dry run damage Every Davey Silensor is thoroughly tested against a number of pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performance that lasts and lasts Location The pump should be located as close to the water as practicable and mounted on a firm base in a well drained position high enough to prevent any flooding It