        INSTALLATION MANUAL
         Contents
1.   2050 to 2450 Pa   e Adjust only if outside this range  e USE LARGE HIGH GAS ADJUSTMENT SCREW    hold small adjustment screw still    Low gas  adjustment    High gas LAS  adjustment  lt  ENSURE BOTH  LEADS ARE  CONNECTED TO    MODULATING COIL  WHEN FINISHED    Outlet pressure  test point             5   Braemar  rubs rHivps    Crente POOLING       SYSTEM SETUP    Note that the settings below can only be adjusted within  the first hour of powering the SCC  After that  disconnect  the SCC loom  discharge the SCC capacitor then  re connect the loom     Set the time  amp  day  SCC thermostat    e With the SCC in OFF mode  press and hold SET   e Use the UP DOWN arrows to adjust the time  press  SET when satisfied   e Use the UP DOWN arrows to adjust the day  press  SET when satisfied    Set the heater  amp  cooler type  SCC thermostat     e With the SCC in OFF mode  press SET  amp  AC MODE  simultaneously    e THD3 use the UP DOWN arrows to adjust the heater  type to HEAT 3  factory default   press SET when  satisfied   e THMD5 use the UP DOWN arrows to adjust the  heater type to HEAT 4  press SET when  satisfied   e Use the UP DOWN arrows to adjust the cooler type   press SET when satisfied  e COOL 1   evaporative  factory default    e COOL 2   refrigerated  THMD5 only     Set maximum fan speed  THMD5 ONLY     e Press and hold SET and press FAN   e Check the air flow from all outlets   e  f required  adjust the fan speed  7  8  9 or 10  using  the UP DOWN arrows  Press SETwhen s
2.  e  Remove heat exchanger end panel and heat shield    e Carefully detach the bundled thermistor cable from  the overtemp bracket    e Feed thermistor cable and bracket down to  supply return air plenum base panel    e Secure thermistor bracket using screw provided into  previously drilled pilot hole with long fold towards  supply air cutout                                                  Bundled thermistor cable       Plenum supply  air cutout    Flue connection    THD3   Powder coated die cast flue terminal THMD5   Powder coated metal flue terminal  e Attach powder coated die cast flue terminal to heater e Attach flue connection spigot to heater over flue outlet  over flue outlet  fixing in place using screws supplied using screws supplied with heater   with heater  e Attach powder coated metal flue terminal to flue  e A flue guard kit is available P No 079073 connection spigot  fixing in place using screw supplied  with heater   e A flue guard kit is available P No 079073    THMD5  When reversing the flue outlet the flue outlet panel  must be relocated to the other side of heater  to ensure the combustion air inlet louvres are on  the same side as the flue terminal     THOS FLUE THMD5 FLUE    Flue outlet panel                      Flue connection spigot    External powder coated metal  flue terminal  THMD5     External powder coated die cast  flue terminal  THD3                    Fix in place with screw    3   Braemar     runs  THMDs    HEATING   COOLING    THERMOSTAT LO
3. CAL CONNECTION    e Electrical wiring  amp  fittings must be installed by a licensed Electrician    e Seeley International recommends that all Braemar gas ducted heaters are wired with a dedicated circuit from the  distribution board with a separate circuit breaker    e Wiring must be installed in accordance with the relevant electrical standards  amp  regulations    e The electrical supply must be 240V 50Hz    e A suitable 10A 3 pin 240V GPO must be fitted adjacent to the heater  IMPORTANT   e Ensure that the polarity of the power supply is correct  ENSURE HATIP OTAR OE   GAS CONNECTION    e All gas supply piping must be installed by a licensed gas fitter in accordance with    Standard AS NZS 5601 Gas Installations   e Gas connection point   All models   3 4  BSP female flare nut     e Gas supply piping must be sized to ensure a minimum gas pressure of 1 13 kPa for  natural gas appliances or 2 75kPa for propane appliances at the inlet to the heater with  the heater and all other gas appliances operating at maximum gas rate  Detailed pipe  sizing information is contained in Standard AS NZS 5601 Gas Installations    e The maximum gas rate for the heater is located on the specification label on the    underside of the heater lid     e An AGA approved gas cock manual shut off valve must be fitted in the gas supply line  adjacent to the heater  outside the heater cabinet  to enable isolation of the heater for    maintenance and or servicing   e Ensure that all air is purged from 
4. CATION    THD3   2 wire thermostat or Braemar SCC    THMD5   SCC  to achieve 5 2 star rating     The wall control should be located central to the main  living area approximately 1 5m above floor level  The  main living area should be confirmed with the occupants     Wall control placement is critical to ensure correct  functioning of the heating system  The following points  must be taken into account     e Avoid direct sunlight    e Avoid mounting on external walls    Avoid mounting near heat sources such as stoves   TV sets etc    Do not locate in the air stream from an outlet register   Do not locate in draughty areas    Do not locate in hallways    Do not locate adjacent to return air grille    Always fill cable entry hole in wall     24V  manual  digital thermostat  THD3 ONLY     THD series heaters can all be used with a standard  2 wire type manual digital thermostat  Connect a low  voltage 2 wire loom between the thermostat and   T STAT  on the BSC circuit board  Note that with  Braemar THD3 series heaters zoning and evaporative or  refrigerated cooler operation is not possible with these  thermostats              Mus       o                                        Braemar Spectrolink Comfort Control  SCC     e A 20m loom is supplied with the heater for  connnection directly between the heater and the  SCC    e Feed the wiring loom through the large hole in the  SCC mounting bracket and attach the mounting  bracket to the wall    e Plug the wiring loom into the socket 
5. Check flue cowl is installed correctly  e Check wiring to pressure switch is not dislodged    Spark but no ignition   e Check gas valve on off switch is set to ON   e Check flame roll out switch is closed  press red  button     Room fan does not start  e Check room fan wiring connected correctly    All checks OK but still does not start  e Disconnect power  wait 5 minutes and start again    If the heater still does not start or operate correctly  after running through these troubleshooting and  diagnostic checks contact     WARRANTY SERVICE  1300 650 644  TECHNICAL SUPPORT  1300 650 399    Please have your appliance model number  serial  number  and any displayed fault codes available  prior to calling        Example  THMD520N       SEELEY INTERNATIONAL     INSTALLATION MANUAL    6    SAFETY INSTRUCTIONS    Employers and Employees Responsibility    The installation and maintenance of gas ducted heating  units  particularly at height  has the potential to create  Occupational Health and Safety issues for those  involved  Installers are advised to ensure they are  familiar with relevant State and Federal legislation  such  as Acts  Regulations  approved Codes of Practice and  Australian Standards  which offer practical guidance on  these health and safety issues  Compliance with these  regulations will require appropriate work practices   equipment  training and qualification of workers  Seeley  International provides the following information   as a guide to contractors and em
6. SEELEY      INTERNATIONAL    INSTALLATION MANUAL    Braemar Ecostar THD3 THMD5 Gas Ducted Heater       Braemar       HEATING   COOLING          THIS HEATER IS TO BE INSTALLED BY AN AUTHORISED PERSON ONLY  ALWAYS read the operating instructions before operating the appliance     DO NOT place articles on or against this appliance    DO NOT use or store flammable materials near this appliance    DO NOT spray aerosols in the vicinity of this appliance while it is in operation   DO NOT operate this appliance with panels  covers or guards removed     This Braemar gas ducted heater must be installed in accordance with these instructions  local gas fitting regulations   municipal building codes  electrical wiring regulations  Australian Standard AS NZS 5601 Gas Installations and any other  relevant statutory requirements     This heater must not be installed downstream from an evaporative cooler  air washer or indoor unit of a refrigerated  system  This heater is not suitable for installation in a marine environment     Gas Type  Refer label alongside gas inlet   Gas Consumption  Refer data label on underside of appliance lid     UNPACKING THE HEATER    Remove the plastic wrap and cardboard transport cover  Check that the heater model and gas type are as required    model details are provided on the specification label on the end panel of the heater  gas type is given on the label next to  the gas inlet  Report any transit damage within 7 days   do not install the heater if it is dam
7. aged     Dimension  mm      Hes Modal TS TST STE TESTA LTT ET LIMES PSR TS De   ee     oe T         re     ow      e            pss   olele      Lm  oo     eleele      0m        t  G    M i                                                                 N    z j  I  X k l    lourEr    f  AIR INLET      1  suppty       RETURN         7   7      wm mm 1 r          OUTLET  AIR INLET    SUPPLY RETURN                      Bottom View    MINIMUM FLUE CLEARANCES    fomm eral gas meter  From a drain pipe or soil pipe        in pip ree e From a mechanical air inlet  including a spa blower   300mm I i   e Vertically below an openable window  on mechanical     Roa any other flue terminal  cowl  or combustion air air inlet  or any other opening into a building with the  intake     exception of sub floor ventilation     1500mm   e Horizontally in the direction of discharge from an  openable window  door  non mechanical air inlet  or  any other opening into a building with the exception of    e Below eaves  balconies  and other projections    e Horizontally from an openable window  door   non mechanical air inlet  or any other opening into a  building with the exception of sub floor ventilation     500mm n sub floor ventilation   e From electricity meter or fuse box   e From a return wall or external corner  Refer also  AS NZS 5601 Gas Installations    e Horizontally from any building structure or obstruction  facing a terminal     1   Braemar    THD3  THMDS    HEATING J COOLING    ELECTRI
8. atisfied     Balance the air flows    e With the heater running and all outlets open  adjust  balancing dampers to achieve a suitable air flow from  each outlet     Programming the thermostat  SCC thermostat     e Discuss auto program requirements with the  customer     To enter programming mode press and hold SET with  the SCC in AUTO mode  e Use the UP DOWN arrows to adjust the day or group  of days to be programmed then press SET   system  goes to WAKE time period  e Adjust time  temperature  zones and fan speeds   e Use UP DOWN arrows to adjust start time then  press SET  e Use UP DOWN arrows to adjust required  temperature then press SET  e System will go to next time period  e Repeat setting procedure for AWAY  HOME and  SLEEP time periods    Explain system operation to customer    e Explain the operation of the system to the  customer home owner    e Hand the operating instructions and warranty card to  the customer home owner        DIAGNOSTIC CODES THD3    SCC thermostat required   refer service manual for full instructions                                            poos Description Pewee   SCC display  1 P 100 closed at start Li Reset  1  2 P 100 failed to close ti Reset  2  3  P 100 open during run SSD Normal  7 Ignition failure L Reset  7  9 Internal memory failure L2 INS Reset  9  10   HX OT1 opened SSD L1 Normal  11__   EFS shutdown SSD L1 Normal  19  HX OT2 open at start L2 Ns Reset  19          DIAGNOSTIC CODES THMD5  SCC thermostat required   refer service ma
9. gas line   e Ensure that there are no gas leaks     GAS INLET PIPE    e Remove gas inlet pipe from inside the heater     e Fit grommet supplied  to gas inlet pipe transport hole     HEATER INSTALLATION    e Remove old heater from supply return air plenum and  discard    e Check supply return air plenum structural integrity   If plenum is damaged the plenum will need to be  removed and a TH or THM ducted heater will need  to be installed     Installing thermistor preperation  THMD5 ONLY     Thermistor location is CRITICAL to the correct operation  of the heater     e Drill 2 5mm pilot hole in the centre of plenum supply  air cutout 30mm from inside face     Attaching heater to supply return air plenum    e Place strip of adhesive foam tape supplied in heater  along top of supply return air plenum centre panel   e Lower heater onto supply return air plenum     ENSURE FAN END OF HEATER IS LOCATED OVER  RETURN AIR SIDE OF PLENUM                       Gas Connection  All Models    Gas inlet pipe  transport hole       Pilot hole for thermistor bracket  required on supply outlet side only   Installer to check which side is  supply outlet air         Suppl  air qirachon              30mm    Supply return air plenum          Supply return air plenum  NOT SUPPLIED WITH BRAEMAR HEATER    be          SEELEY INTERNATIONAL     INSTALLATION MANUAL 2        Installing Thermistor  THMD5 ONLY   Overtemp bracket       Thermistor location is CRITICAL to the correct operation  of the heater      
10. n off Off Off   On Off Off Off    Flash  1s on 1s off  Flash  1s on 1s off       P 25 50  On Flash    closed at start    1s on 1s off   1s on 1s off    Flash    Off    Off       P 100     On  failed to close    Off    Off    Off    2s on 2s off       P 75   failed to close on    Off    Off    Flash  2s on 2s off       P 25 50   failed to close on    2s on 2s off   2s on 2s off    Off       P 100       On  open during run    On       P 75   open during run    Flash  1s on 1s off       P 25 50   open during run  Flash  1s on 1s off       Flash  1s on 1s off       Off    Flash  1s on 1s off  1s on 1s off             dipswitch       settings                   TROUBLE SHOOTING  amp  DIAGNOSTICS  If the heater fails to start  try the following     No power    Is green LED on BSC circuit board on   Plug in heater supply lead   Turn on power   Turn on circuit breaker    No gas supply   e Min  supply pressure    1 13 kPa  NG     2 75 kPa  LPG   e Has gas meter been installed   e Turn gas on at gas meter    Thermostat not connected   e Connect  manual 2 wire  thermostat to  MAN  T STAT  terminals on circuit board  Connect Braemar Spectrolink CC to  CC  terminals  on circuit board    No thermostat communication   e Check for  YES  on SCC display when first powered    Thermostat not calling for heat  e Adjust set point above current room temperature   e Check LED s   centre LED  red  on steady    Combustion fan does not start  e Check that the fan is not blocked or jammed    No spark  e 
11. nual for full instructions                                                  a Description Srur Sawa SCC display  1 P 25 50 closed at start A Reset  1  2 P 25 50 failed to close L1 Reset  2  3  P 25 50 open during run ssp Normal  4  Thermistor  gt  70oC during run ssp Normal  5 Thermistor not connected or short circuit L1 Reset  5  7 Ignition failure L1 Reset  7  9 Internal memory failure L2   Reset  9  10  HX OT1 opened SSD L1 Normal  11  EFS shutdown SSD L1 Normal  12  P 75 100 closed at start L1 Reset  12  13  P 75 100 failed to close LA Reset  13  14  P 75 100 open  gt  30 sec during run SSD Normal  15  Thermistor in cool location in duct ssp Normal  46  Thermistor not installed in outlet duct 1ST DC16 L1 Reset  16   2ND DC16   L2  N  Reset  16  19  HX OT2 open at start L2 NX Reset  19                          s Shut down type dependent on current operating    status   SSD Safety shut down   L1    Reset not required   Lockout 1  User reset from SCC  press RESET    twice   or Manual t stat off on off on    wait 5 seconds at each state  or Power  off   power on     L2    Lockout 2  Reset from SCC service mode only    MODULATING CIRCUIT BOARD  MCB   LED INDICATORS THMD5    LED 2  RED    LED 1    Status GREEN    LED 3  RED    LED 4  RED    LED       RED    Power on  Heater off    100  gas       75  gas  50  gas    ee             25  gas  P 100   closed at start  P 75   closed at start    On Off Off Off Off  O On On On On  On On On On off  On On On off off  On On Off Off off  O
12. on the SCC and  carefully slide the SCC into the mounting bracket     SCC connection THMD5    e The SCC is connected directly to the MCB  note that  this is different to Braemar TH heaters where the  SCC is connected to the BSC      Braemar  Speticokert       SCC connection THD3    e The SCC is connected directly to the BSC        COMMISSIONING THD3   INSTALLER    OR COMMISSIONING AGENT    Installation checks    e Check for gas leaks   rectify any leaks found    e Check that the flue system is connected  sealed and  installed with appropriate clearances    e Check that thermostat is wired correctly and installed  in a suitable location    e Check that the heater is level in both directions    Gas pressure checks    e Connect a manometer to the outlet pressure test  point on the gas valve   e Start the heater     THD3    Run heater and check pressure at outlet test point   adjust if necessary     All natural gas models     Propane models     THD3 15 20 2500     200 Pa    THD330 1900     200 Pa    875     50 Pa       OUTLET PRESSURE REGULATOR  TEST POINT ADJUSTMENT  OVER                            Gas Out                                                                                                                      Set maximum fan speed    e Turn the heater on at the thermostat and allow to run  for 5 10 minutes to reach operating temperature    e Check the air flow from all outlets    e If required  adjust the fan speed by turning the  trimpot located on the BSC board  al
13. ongside the  10 pin connector     e Fully clockwise   fan speed 10   e Fully anti clockwise  3 4 turn    fan speed 7    aig oe  eeNsPEED  O    DECREASE       SEELEY INTERNATIONAL     INSTALLATION MANUAL 4    COMMISSIONING THMD5  INSTALLER  OR COMMISSIONING AGENT    Installation checks    e Check for gas leaks   rectify any leaks found    e Check that the flue system is connected  sealed and  installed with appropriate clearances    e Check that thermostat is wired correctly and installed  in a suitable location    e Check that the heater is level in both directions     Gas pressure checks    e Connect manometer to outlet pressure test point on  gas valve    e Start heater as described in Owner s Manual    e Wait 30 seconds after heater lights to ensure heater  has reached high gas rate     Check high gas    e High gas pressure    NaturalGas Nominal 875 Pa  825 to 925 Pa     Propane Nominal 2250 Pa  2050 to 2450 Pa   e Adjust only if outside this range  e USE LARGE HIGH GAS ADJUSTMENT SCREW    hold small adjustment screw still    Check low gas    e  Remove one lead from modulating coil  LOW  VOLTAGE  0 17 Vdc   e Low gas pressure     Natural Gas Nominal 100 Pa  90 to 110 Pa     Propane Nominal 180 Pa  170 to 190 Pa   e Adjust only if outside this range  e USE SMALL LOW GAS ADJUSTMENT SCREW    hold large adjustment screw still    Re check high gas  e Re connect lead to modulating coil  e High gas pressure     Natural Gas Nominal 875 Pa  825 to 925 Pa     Propane Nominal 2250 Pa
14. people  used    e Are all tools and materials being used  prevented  from slipping and falling onto a person at ground  level  Is the area below the work area suitably  protected to prevent people entering this area    e Does the work schedule take into account weather  conditions  allowing for work to be suspended in high  winds  thunder storms lightning or other types of  weather giving wet  slippery surfaces    e ls there an on going safety check system of  harnesses  ropes  ladders and access lifting  equipment  and any anchor points on roofs before the  commencement of work    e Is there a system which prevents employees from  working on or in roofs if they are unwell or under the  influence of drugs or alcohol    e Are there any special conditions to consider i e   excessive roof pitch  limited ground area  fragile roof   electrical power lines        Warranty Service  Australia 1 300 650 644  seeleyinternational com    It is the policy of Seeley International to introduce continual  product improvement  Accordingly  specifications are  subject to change without notice  Please consult with your  dealer to confirm the specifications of the model selected     Braemar       HEATING   COOLING    www braemar com au       
15. ployees to assist in  minimising risk     Risk Assessment    A risk assessment of all hazardous tasks is required  under legislation  A risk assessment is an essential  element that should be conducted before the  commencement of work  to identify and eliminate the  risk of falls and other risks  or to minimise these risks by  implementing control measures  This does not need to  be a complicated process   it is a matter of assessing  the job to be done and considering what actions are  necessary so the person doing the job does not injure  themselves     This should be considered in terms of    e What are the chances of an incident occurring    e What could the possible consequences be    e What can be done to reduce  or better still  eliminate  the risk     Some points to consider    Some points to consider when working on or in a roof   e What is the best and safest access to the roof and  working areas    e What condition is the roof in  Should the roof  structure and surface be checked    e Does the worker have appropriate footwear    e Are all power cables extension leads safe and  appropriately rated    e Are all ladders  tools and equipment suitable and in  good condition    e Where ladders are to be used  is there a firm  stable  base for them to stand on  Can they be tied or  secured in some way at the top    e ls there a roof anchor to attach a harness and lanyard  to  If so  instruction should be issued for the use of  an approved harness or only suitably trained 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Black & Decker F65D Use & Care Manual    Frequently Asked Questions  PDF - UNT Digital Library  NEC 照明器具取扱説明書 保存用  Severin WK 3461 electrical kettle  SIS Instructions for Students  Philips DCM3060  Samsung HMX-Q10BP Brugervejledning  64,000 BTU GAS GRILL USER MANUAL    Copyright © All rights reserved. 