Home
        USER MANUAL Universal Gateway U9921-GUV U9921
         Contents
1.   radiate radio frequency energy and  if not installed and used in accordance with the instructions   may cause harmful interference to radio communications  However  there is no guarantee that  interference will not occur in a particular installation  If this equipment does cause harmful  interference to radio or television reception  which can be determined by turning the equipment  off and on  the user is encouraged to try to correct the interference by one or more of the  following measures       Reorient or relocate the receiving antenna      Increase the separation between the equipment and the receiver      Connect the equipment into an outlet on a circuit different from that to which the receiver is  connected      Consult the dealer or an experienced radio TV technician for help     You may also find helpful the following booklet  prepared by the FCC   How to Identify  and Resolve Radio TV Interference Problems   This booklet is available from the U S   Government Printing Office  Washington D C  20402       In order to maintain compliance with FCC regulations shielded cables must be used with  this equipment  Operation with non approved equipment or unshielded cables is likely to result  in interference to radio  amp  television reception   8 of 10  19541P 42  04 11     Industry Canada Statement  This device complies with Industry Canada licence exempt RSS standard s   Operation is subject  to the following two conditions   1  this device may not cause interference 
2.  Kit  P N  41045G 01     Care and Maintenance    The U9921 GUV is not user serviceable  Do not attempt to open the enclosure  If this product    requires service  please contact the David Clark Customer Service department     19541P 42  04 11     Phone  800 298 6235    E Mail  serviceWWW  DavidClark com    By Mail  Customer Service    David Clark Company    360 Franklin Street    Worcester  MA 01604    7 of 10       If necessary  the U9921 GUV may be wiped down with a mild soap and water mixture  Although  it is a sealed device designed to withstand submersion in water to 1 meter  do not unnecessarily  submerse this product in water     Avoid storage of this product in direct sunlight or high temperature environments                       Specifications   Frequency Range 1920 MHz   1930 MHz  U S  and Canada   1880 MHz   1900 MHz  EU    Average RF Power Output 4 mW  100mW peak   U S  and Canada   10 mW  250 mW peak   EU    Range 300 ft  100m  line of sight  nominal    Operating Temperature  14  F to 113  F   10  C to  45  C    Storage Temperature  4  F to 140  F   20  C to  60  C    Power Requirements 8 to 25VDC                FCC Part 15 Statement    RADIO AND TELEVISION INTERFERENCE    This equipment has been tested and found to comply with the limits for a Class B digital device   pursuant to Part 15 of the FCC rules  These limits are designed to provide reasonable protection  against harmful interference in a residential installation  This equipment generates  uses and can
3.  and  2  this device  must accept any interference  including interference that may cause undesired operation of the  device    Unauthorized Changes  Changes or modifications not expressly approved by David Clark Company  Inc  could void the  users    authority to operate the equipment    FCC Radiation Exposure Statement  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled  environment  This equipment should be installed and operated with a minimum distance of 20  centimeters  8 inches  between the radiator  antenna  and your body  This transmitter must not  be co located or operating in conjunction with any other antenna or transmitter    Usage Restrictions    US Models    Due to the UPCS frequencies used  this product is licensed for operation only in the United States  of America and Canada     EU Models    Due to the DECT frequencies used  this product is licensed for operation only in the European  Union countries     9 of 10  19541P 42  04 11     Appendix A  Mounting Templates                Figure A2  Bracket Mount     Optional  P N  41045G 01     19541P 42  04 11  10 of 10    
4. 21 GUV may be flush mounted or surface mounted using the included gasket  nut  and  bracket  See Figure 1 for mounting suggestions    Note  Bracket  P N  41045G 01  optional  Not used for flush mount applications  Bracket  mounting configuration may be reversed for varying requirements  e g   vehicle dash vs  ceiling   mount      See Appendix A for Mounting Templates   Antenna    The U9921 GUV has an internal antenna  An external antenna may not be necessary but the  antenna connector is provided for either the included whip antenna or an optional remote  antenna kit  P N  40688G 93 for mag mount  40688G 96 for permanent install      Choose an open  clear location for the remote antenna and route the coaxial cable away from  any busy areas  preferably behind panels or in conduits     This device has been designed to operate with the antennas listed below  and having a  maximum gain of 3 dB  Antennas not included in this list or having a gain greater than 3 dB are  strictly prohibited for use with this device  The required antenna impedance is 50 ohms     3 of 10  19541P 42  04 11     Acceptable antennas for use with this product     Linking    e Whip Antenna  P N  40688G 92   e Remote Antenna Kit  Mag Mount  P N  40688G 93   e Remote Antenna Kit  Permanent  P N  40688G 96     Before a belt station and a gateway can be connected  they must first be linked  As a security  measure  the close link feature requires devices to be in proximity of between 1 to 3 ft  0 3 to  0 9m  in 
5. d in conjunction with one or more U9910 BSW  40992G 01  or U9912   BSW  40992G 02  Wireless Belt Stations  becomes part of a wireless intercom system  The  U9921 GUV provides communication for up to four users as well as an interface to an existing  wired intercom system  Up to four belt stations can be connected to one gateway     Antenna  Connection          Status LED          Threaded  Post          Interface  Connector                            C UNIVERSAL GATEWAY ot             Figure 1  Overview of Gateway    2 of 10  19541P 42  04 11     Installation    Intercom Interface    The U9921 GUV is designed to add wireless capability to an existing wired intercom  Connection  to the intercom is accomplished by connecting an interface cable to the interface connector of  the U9921 GUV  see Figure 1   The following list contains David Clark intercom systems that  have been tested to work with the U9921 GUV and the required cable assembly     Table 1  Intercom Interface Cable Assemblies       David Clark Intercom Cable Assembly Required  U3800 Vehicular Intercom System   C99 22MS  40935G 08   U9800 Marine Intercom System C99 20CX  40935G 07   U9500 Marine Intercom System C99 20LL  40935G 06   U3400 Portable Intercom System  U3100 Modular Intercom System                C99 20MS  40935G 05                 The U9921 GUV will detect the cable assemblies listed above and automatically make the  necessary audio level adjustments for the corresponding intercom     Mounting    The U99
6. e David  Clark    WWW DAVIDCLARK COM    USER MANUAL  Universal Gateway    U9921 GUV U9921 GUV EU    P N  40994G 01   P N  40994G 02        19541P 42  04 11    2011 DAVID CLARK COMPANY INCORPORATED    Cautions and Warnings    19541P 42  04 11     READ AND SAVE THESE INSTRUCTIONS  Follow the instructions in this installation  manual  These instructions must be followed to avoid damage to this product and    associated equipment  Product operation and reliability depends on proper usage     Y    N        amp      x     DO NOT INSTALL ANY DAVID CLARK COMPANY PRODUCT THAT  APPEARS DAMAGED  Upon unpacking your David Clark product   inspect the contents for shipping damage  If damage is apparent   immediately file a claim with the carrier and notify your David Clark  product supplier     ELECTRICAL HAZARD   Disconnect electrical power when making any  internal adjustments or repairs  All repairs should be performed by a  representative or authorized agent of the David Clark Company     STATIC HAZARD   Static electricity can damage components   Therefore  be sure to ground yourself before opening or installing  components     LI POLYMER   This product is used with Li Polymer batteries  Do not  incinerate  disassemble  short circuit  or expose the battery to high  temperatures  Battery must be disposed of properly in accordance  with local regulations     1 of 10    Overview    The U9921 GUV  40994G 01  Universal Gateway is a fixed mounted wireless communication  device that  when use
7. e belt station User Manual for the individual belt station purging procedure when remaining  link purging may be necessary      Smart Purge procedure    1  Ensure the gateway is powered on and functioning    Disconnect all belt stations to be purged  power off the belt stations     3  Verify the number of green LED flashes on the gateway matches the number of  belt stations to be kept linked    4  Press and hold LINK button on the gateway for 30 seconds until LED quickly  flashes red    5  Release LINK button     m    6 of 10  19541P 42  04 11     Troubleshooting    Table 3  Troubleshooting       Problem    Solution       Gateway will not turn on    Ensure correct interface cable is being used   Table 2        Cannot link a belt station    Review Registration procedure   Ensure units are within 1 to 3ft  0 3 to 0 9m   of each other   Try a Smart Purge          Cannot speak over two way radio       PTT not pressed  Two way radio not installed to system       Replacement Parts    Interface cable assemblies        David Clark Intercom    Cable Assembly Required       U3800 Vehicular Intercom System   C99 22MS  40935G 08        U9800 Marine Intercom System C99 20CX  40935G 07        U9500 Marine Intercom System C99 20LL  40935G 06           U3400 Portable Intercom System  U3100 Modular Intercom System    C99 20MS  40935G 05              Whip Antenna  P N  40688G 92     Remote Antenna Kit  Mag Mount  P N  40688G 93   Remote Antenna Kit  Permanent  P N  40688G 96   Mounting Bracket
8. olid PTT asserted  Green Slow Connected  pattern indicates  number of belt stations connected                    Operation  Communication    All connected belt stations will be able to communicate with each other through the U9921 GUV  while in range  and per the VOX settings on a VOX belt station   Additionally  all belt station  users will have communication over the intercom  If the intercom is so equipped  pressing the  PTT button on a VOX belt station will allow the user to transmit over the system s two way radio   Pressing the PTT overrides the VOX setting on a VOX belt station  Multiple VOX belt station users  may PTT and thus speak over the two way radio simultaneously  For more information consult  the user manual for the belt station     Wireless users who are not pressing PTT while another wireless user is pressing PTT  will not be heard on the wired intercom while the PTT remains pressed     Intercom Level Adjustment    Audio levels can vary between intercoms  mainly due to the system level setting on the wired  intercom  To compensate for this  the U9921 GUV has the ability to adjust its receive level from  the intercom using the Vol keys  see Figure 1   Pressing these keys will increase or decrease the  audio level coming from the wired intercom into the gateway  Perform this adjustment to obtain  optimum performance     Receive Level Adjustment Procedure    1  Connect at least one belt station to the U9921 GUV gateway and ensure sidetone is  present  see belt 
9. order to successfully link  This ensures that the units are not inadvertently linked with    other units on the premises     Linking procedure     1   2     Ensure units are within 1 to 3 ft  0 3 to 0 9m  of each other    Simultaneously  within 1 2 sec  press and release the LINK button on the U9921 GUV and  the power button on the belt station to link with    Amber LED s will flash on both devices  A momentary red LED indicates a successful  close link    Upon successful link the U9921 GUV will attempt to establish a connection with the belt  station    Upon successfully establishing connection the LED on the controller will flash a green  pattern corresponding to the number of belt stations connected     Once linked  the devices will not need to be linked again unless they are purged  see  Purging      Each belt station is able to be linked to only one gateway at a time  A gateway can have up to six  belt stations linked and be connected to four of those six at one time     Status Indications    The front panel has a multi color LED in the center which serves as a status indication for the  gateway  Table 1 below lists these states     19541P 42  04 11     4 of 10    Table 2  LED Status Indications                               LED Color Blink Rate Status  Red Solid Initializing power up  Red Once Connection Dropped  Red Once Connection Established  Red Any Low battery  approx  1 hr remaining   Orange Slow Idle Disconnected  Orange Fast Link Connection in Progress  Orange S
10. station User Manual     2  Begin speaking and slowly and repeatedly press the Volume Up key on the U9921   GUV gateway until you hear an echo of your own voice    3  Continue speaking and press the Volume Down key until the echo stops    4  You may wish to verify communication with someone hard wired to the intercom    5 of 10  19541P 42  04 11     Range    The range of a belt station and a gateway can be up to 300 ft  100m   If you are in an  environment with metal or concrete walls  this range could be reduced  When the belt station  travels out of range of the gateway  a voice alert will indicate that the connection has been lost   To reconnect  simply move back into range and connection with the gateway will automatically  be reestablished  also noted by a voice alert     Purging    In some circumstances it may be necessary to    purge    the U9921 GUV of some of its linked belt  stations  Typically purging is not necessary unless there are multiple gateways in the same  vicinity and you wish to remove a belt station from this gateway and link to a different gateway   A gateway can link up to six belt stations where a belt station can be linked to only one gateway  at atime     Smart Purge    A smart purge is the purge method employed for the U9921 GUV  in which only unwanted links  are removed from the gateway  When this procedure is complete  only belt stations that are  connected to the gateway remain linked  All other belt station links will have been removed  see  th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
netANALYZER software installation IG 01 EN  Ingersoll Rand 2475F14G Use and Care Manual  必ず2人以上で作業を行ってください。  Mode d`emploi Balance compacte KERN FCB  Sony VCT-MP1 Precautions  Samsung WB650 manual de utilizador  YOUR PO49X PIZZA OVEN CONNECTING TO POWER    MANUAL DE INSTALACIÓN  termostato programable a 7 días o 5/2 días, o no    Copyright © All rights reserved. 
   Failed to retrieve file