Contents
1. 3 4 5 6 8 Please setup the NC NO EOL type in the PC Programmer correctly If you setup the Nodes type as NC Default the no use inputs must be with short circuited by wires and the sensor type must be NC Please see below diagram If you setup the input type as EOL then please contact a 2 2K Resistor in series with every inputs if you don t connect the sensor to the inputs please connect a 2 2K Resistor in series to instead of it Moreover only the digital detector is NC type can use in EOL mode Please see the below diagram If you setup the input type as NO then please keep the two points of the inputs by free and the sensor type must be NO Please see the below diagram The Unit built in 240VAC 3A rated relay Please make sure the power cord rated while you connect to equipment device also please make sure the power consumption is less than 250W for long time working If you need heavy equipment please connect an additional relay The R1 and R1 is for alarm link output when the system alarm will close for 4 minutes the rated output power is 700W If you need heavily equipment please connect an additional relay The R2 and R2 is the relay output for SMS Command CC is close DD is open EE is inquiry the status The 12VDC is for the Detectors if the detectors need 12VDC power then please contact it to the 12VDC The 12VDC power is from external power not from backup battery So please
2. GSM House Alarm System S110 User Manual Ver 1 00 Date Issued 2010 09 01 All rights reserved by King Pigeon Hi Tech Co Ltd Website Http www GSMalarmsystem com N A YW K Y WN p LI 12 13 14 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Table of Contents Brief introduction 2 Safety Directions 2 Standard Packing list 3 Physical Layout 2 2 2220200000000000 3 Features 2 22222 22222222 ne enn nen nn nerenceennenenn 6 SCILINGS 2 222 nnn nen n nnn n enn n nnn n nnn nnnnnnnn 8 Operating Instructions 18 Installation 21 Add wireless Sensors 26 Technical specifications 28 Important information 29 MaintenanCce 22 29 Quality Warranty 29 Trouble Shooting Guide 30 King Pigeon Hi Tech Co Ltd Page of32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 1 Brief introduction The GSM Alarm System S110 is a new security protection solution special for home house and office and other applications It based on Wireless GSM Communication network in
3. Please trigger the new wireless sensor Then following the instruction to add the new wireless sensor to the S110 For Remote control it will display VVVV if the unit has been assigned remote control Both of them you can press Enter to re assign new wireless sensor or remote control to replace the existence one 3 Inthe Edit RF Parts you can edit the attribute of the sensor as Normal or Stay Type If the system is under Stay Mode Also said At House or Partial Armed the sensor set King Pigeon Hi Tech Co Ltd Page of32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com as Normal triggered will not alarm the sensor set as Stay triggered will Alarm If the system is under Armed Mode then all RF sensors triggered will alarm This is very important to remember the sensor types of the system This function is very useful when you at house and need some sensors in working status E g the sensor installed outer and gas and smoke detectors etc and some sensors indoor not in working status e g the sensors installed in the living room bed room etc 4 The S110 can accept total 16 wireless sensors to 16 wireless zones each zone can be assigned one wireless sensor and renamed it by SMS Command And 5 remote controls Wireless Zone Serial Number Default Zone Name and Zone Attributes Table a a o1 intrusion from Entry Door Normal OOOO 06 intrusion from Front Balco
4. 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 6 2 2 1 Add Del RF Parts To setup the zone s attribute and add new wireless sensors to specificities zone To add new remote controls To remove all registered wireless sensors and remote controls 1 Zones Attribute definition and not alarm in disarmed mode sensors with Normal type triggered will not alarm In the starting time point and ending time point the sensors with Watchdog this type triggered will not alarm if the sensor hasn t been triggered will make alarm In any mode the sensors with this type triggered will alarm but j SOS Help not drive the siren Alarm Action when Alarm occurrence the system will Automatically dial the Pre set Auto Dial Tel Numbers for 3 times one by one and Send SMS to the Pre set SMS Alert Numbers in the meantime will drive the siren for 60seconds and close the link Output relay for 4 minutes 2 After you enter the menu the attribute of the zone will be displayed in the LCD if this zone has been assigned wireless sensor will display V If hasn t been assigned wireless sensor means this zone is empty you can assign new wireless sensor to this zone Press Up or down button on the keyboard to check the other Zones Press Enter to edit it After you pressed the Enter button you can select the zone attribute and then press Enter you can see Turn on the device or
5. SOS on the remote control or the control unit or Press any Emergency button The Control Unit will enter emergency alarm The siren will not sound but will alert the pre set phone number immediately 7 2 SMS Commands for Arm or Disarm or Inquiry system status or switch on off independent output relay The User can Arm Disarm Inquriysystem status Switch on or off the independent output relay by sending SMS to the Control unit The SMS Commands are below The system will carry out the commands immediately with no delay after the Control Unit receive this SMS command 7 2 1 Armed King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com XXxxAA xxxx Stands for the password 1 4 digits Return SMS All Armed Mode activated 7 2 2 Disarm XxxxBB xxxx Stands for the password 1 4 digits Return SMS System deactivated Example 1234AA When the Password is 1234 Example 1111BB When the Password is 1111 7 2 3 Switch On the independent output relay xxxxCC xxxx Stands for the password 1 4 digits Return SMS Output Relay Closed Example Hee When the Password is 1111 7 2 4 Switch OFF the independent output relay xxxxDD xxxx stands for the password 1 4 digits Return SMS Output Relay Opened 7 2 5 Inquiry System Status King Pigeon Hi Tech Co Ltd E
6. Supports armed Partial armed At House or Stay or disarmed SOS by remote control or mainframe keyboard Supports armed disarmed inquiry mainframe status switch on or off relay output by SMS Commands Automatically send SMS Alert and dial to the pre set cell phone when any sensor had been triggered Equips with 16 Wireless Zones and 8 Wired zones zone attribute Normal At House or Stay mode and Zone Name is editable 3 X 24 Hour zones for smoke and gas leakage sensor 1 XWatchdog zone for monitoring elder or child 1XSOS zone for emergency help Supports 3 SMS Alert Numbers and 5 Calling alert numbers and 100 Alarm Records for owner review Supports Timer for automatically arm or disarm the system Supports armed delay to give enough time to you go out the home the delay time is editable by user Equips with 1 Alarm Link output relay once the system triggered the output will switch on for 4minutes Equips with 1 seperate output relay it can be switch on or off by SMS Commands This is very useful for remote switch on light or off while you re in another city in the night The Keypad can use as a dialer the functions like the Cell phone The external power failure amp recovery alert function is optional Supports wiretap through the internal microphone Supports internal Speaker to special user for two way voice communication It is Compatible with PT2262 2264 and PT2242 wireless IC King Pigeon Hi Tech Co Ltd Page
7. power is recovery then will send SMS AC Power is OK Default is disabled 6 There s no delay for Stay Mode King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 6 2 2 4 Advanced Setting To setup the starting time to arm and the Ending time to disarm To setup the starting and ending time to work To setup the remote control operation report function To setup the GSM Jammer Alert function Modify the system password Restore the system settings to factory defaults All of the remote controls and wireless sensors should be re assigned again 1 2 3 The watchdog is special for elder or child or on duty personnel in the period Starting time point to Ending time point if this sensor hasn t been triggered the system will alarm This is very useful to monitor the elder or child goes out the bedroom or enters the kitchen to eat something Or monitor the on duty personnel in the polling period have gone to on site inspection If enable the RCO alert function then when use any remote control which has been registered to the system to arm or disarm or stay operation the system will send SMS to the first SMS number If enable the GSM Jammer Alert function when the GSM Signal is 0 for more than 90s the system will drive the siren for 60seconds and the link output relay will close 4 minutes 6 3
8. alarm by Remote Controls Keyboard SMS to Disarm it Another the user can switch on or off the independent output relay by SMS Commands 7 1 Arm or Disarm or Stay Partial Arm At House Arm and Emergency Alarm by remote controls Press the button fi on the remote control or Press Arm button on the keyboard then select Arm the Control Unit enters arm status delay time King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com according to the setting the im ICON will be on Under this status any sensor triggered the control unit will alarm if answered the call the siren will stop and can listen in the alarm area by phone Press the button mi on the remote control or press Disarm button on the Keyboard then input the password the Control Unit disarms immediately The im ICON will be off Under this status any sensor triggered the control unit will not alarm Except the sensor type is the 24 Hour Zones or Watchdog zone or SOS zone Press the button on the remote control or Press the Arm button on the keyboard then select Stay the Control Unit enters Stay Partial Armed status the f ICON will be on In this status the sensors had been set as Stay Type triggered will alarm but the sensors had been set as normal Type triggered will not alarm Please see the menu of the Edit RF Zone Press Emergency button
9. receiving frequency 433 92 MHz Wireless sensor permission quantity 16Pcs Wired Zones 8 Remote Control permission quantity 5Pcs Effective distance wireless of remote control 100 m Battery Built in lithium ion battery 1000mAh 3 7V Standby time Approx 24hours depending on the network condition King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Size 180mmX125mmX30mm LXWXH Net Weight 0 36Kg 11 Important information 1 ee CO N Please read the User Manual carefully before you install the Control Unit and set the Control Unit Do not install the system in close vicinity with objects that generate strong interference such as TV set and computer Install the system in a hidden place Avoid getting water into the Control Unit Have a secure connection to the main power supply This product was designed for the indoor use Opening the control unit cover will avoid the warranty More information will be available of the S110 we will not inform you again after we upgraded please check with your dealers 12 Maintenance 1 2 3 4 If the Control Unit works while the remote control and other sensors fail please check and change the battery lf the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test t
10. special menu need it to choose the option Disarm Button Arm Button At House Stay mode button Pee SOS Panic Button 6 2 Main Menu In standby mode press the Ga button you can see the Menu To check the settings and event records of the system To setup the system functions requires password the default password is 1234 King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 6 2 1 View To check the alarm records up to 100 event records will be saved To check the Timer you have setup To check the SMS Alert Contents of the Wireless Related Zones To check the SMS Alert Numbers To check the Auto dial telephone Numbers To check the report time To check the RF sensor wireless code To check the SMS Alert Contents of the Wired Related Zones 1 The RF Code Query function is for check the wireless sensor transmission You can enter this submenu then triggered the wireless sensor if in the LCD can display some codes means the wireless sensor can transmit wireless signal 6 2 2 Setup To add or remove wireless sensors or remote controls and edit their attributes To setup Wired Zone parameters of the system To setup basic parameters of the system To setup the advanced parameters of the King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No
11. IR Motion Sensor X1 Wired Strobe Siren 110dB X1 Regulated 12VDC Power Supply X1 User Manual X1 GSM Antenna X1 Optional Accessories Wireless Sensors or Wired Sensors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Magnetic Steel Scrolling Door Sensor Temperature Sensor Photoelectric Beams etc 4 Physical Layout 4 1 Control Unit physical layout 1 2 In order to forbidden the intruder power off the alarm system we equipped the power switch inside it is nearby the SIMCard socket please pay attention to it and don t tell others of this Turn it towards inside is off turn it towards outside is on We reserved the plastics of the output relay and Wired sensors in the back cover of the panel Because of some of the users needn t this function If you want to use the output relay and wired sensors please remove the plastics carefully Then you can see the connectors inside King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com O O Power Siren GSM ANT 000 000 Mircophone Interface 1 Description ical External Power Connector Connect to 2A 12V DC power through AC DC Adaptor Hep ri siren should be lt 12V DC Hep GSM ANT Connect the GSM ANT if the GSM signal is not strong then please change the 3dB GSM ANT Microphone One sensitive Microphone built inside Interface 2 Descript
12. Modify the SMS Alert Content of the Zone Zone or Sensor Name The S110 accept SMS Command to modify the SMS Alert Content of the zone For Wireless Zone Name the format is Password M Zone Serial Number 4 New Zone Name the Max Character for the zone name is 32 The Zone Serial Number is 01 16 corresponding to the LCD Menu King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com and 6 2 2 1 table If setup successful the system will return OK to confirm the operation E g Modify the first wireless zone name as Front Door Opened by Intruder You should edit a SMS Content 12344M01 Front Door Opened by Intruder the 1234 is the password Then send it to the S110 Simcard Number For Wired Zone Name the format is Password Z Zone Serial Number New Zone Name the Max Character for the zone name is 32 The Zone Serial Number is 01 08 corresponding to the LCD Menu and 6 2 2 2 table If setup successful the system will return OK to confirm the operation E g Modify the first wired zone name as Front Door Opened by Intruder You should edit a SMS Content 1234 Z01 Front Door Opened by Intruder 4 the 1234 is the password Then send it to the S110 Simcard Number 7 Operating Instructions Tips The user can arm disarm Stay Partial armed by Remote controls Keyboard SMS also the user can cancel the
13. Page of 32 Ver 1 0 www GSMalarmsystem com POSSIBLE SOLUTION Please contact the AC Power Please help to take the panel to a mobile phone repairmen store and then ask the engineer to check the GSM Module socket and the GSM Module connection Please change another position to install the alarm panel When the backup battery voltage is lower than 3 7V the panel will alert by buzzer sounds Please help to contact the AC Power Please replace the battery of the wireless sensor usually once year Please correct the resistor value to 3 3M Ohm of the PT2262 Wireless sensor Please pull out the wireless sensor antenna Please install the wireless sensors or alarm panel away the electric equipments Please contact your distributors or manufacturer to replace it Please see the PIR Motion sensor installation user manual carefully Please check if any sensor assigned to these special zones and made incorrect activated File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Alarm without SMS Alarm without Dial No action after send SMS command 3 NC NO EOL is incorrect GSM Operator communication protocol 3 Please check the detector NC NO type and NC NO EOL Correctly and you re sure connect a 2 2K Resistor in series in the un use input ports Please setup the SMS Alert Numbers Please help to see Page 15 the sample of setup the telepho
14. also be used see below For a Scrolling Steel Door a special Wireless Scroll Steel Door magnetic sensor must be used due to interference of the wireless signal caused by the steel door Installation attach the larger half to the floor and attach rivet or glue the smaller half to the scroll steel door An alarm is triggered when the halves are separated by more than three to 5 00 cm King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com k GPi or aid Fonte sonal Wireless Siqual T m Scroll Steel Door 8 3 Install the wireless PIR Motion Sensor The PIR sensor will detect a person since human temperature is different to ambient temperature When triggered the PIR will signal the Control Unit Apply the detection area illustration below when installing oo 40 degree Wireless PIF motion sensor 50 degree 21m Surveillance Area 5 9m sensor windous infrared infrared 5m 10m 5m 10m Wireless curtain sensor detection area illustration below King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 8 4 Install the Wired Sensors and Electricity equipments Please help to see below wiring diagram then fixed the related wired sensors the sensors connect to the related digital inputs 1 2
15. an add the remote control to the S110 directly following the 6 2 2 1 Add Del RF Parts a Enter the Add Del RF Parts menu King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com b Select 2 Edit Remote Ctrl then press button c then following the instruction 1 Turn On the Devicel means trigger the Remote Control the system will show a code then on the Keyboard The system will ask you repeat the operation so please trigger Remote Control again when you see the Code then press the Enter Button on the Keyboard the system will display Saved OK It means the Remote Control added to the system Repeat this operation to add other remote controls 1 VVVV means this serial position saved one remote control already you can learn a new remote control to replace it 9 4 Delete all wireless sensors and remote controls Go back to the menu then select the Remove All select it then the system will alert Are You Sure gt Press Enter to remove all the RF Parts of the system 10 Technical specifications of Control Unit Rated Voltage 9 12VDC 2A Standby current 30 40mA Siren Output Voltage 12VDC Working temperature 10 C 60 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation Work frequency 900 1800 MHz or 850 900 1800 1 900MHz Communication protocol GSM PHASE 2 2 include data service Wireless sensor
16. be 1234 But the registered wireless sensors and the Wired type will remain 7 Two way communication In standby mode dial the teleohone number following the 2 the system will dial out While incoming call press the E3 Button to answer the incoming Please note if the income calling is from the preset number Includes SMS Alert number and Auto dial numbers then before 6 tones if answered it will create two way voice communications After 6 tones will be entering into wiretap status The user can listen in the alarm around sounds Max time is 10Minutes If the income calling is not from the preset alarm number after 6 tones if hasn t been answered will hang up King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No S1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 8 Ifyou want to test the two way voice communication please make sure the other phone is far from the S110 at least 5 00meters Otherwise the near cross will make lots of noise interference 6 1 Key Function Descriptions La a 8 oe 9 4 4t n System el a oF fh iag J A a z o li 6 1 1 Led indicator Description The S110 uses the icons to stand for the function it is visual and intuitive to users hell 1 oa _ Arm Mode indicator on is in arm mode off is in disarm mode Stay Mode indicator on is in stay mode kK Alarm Indicator on is alarming off is normal
17. his system after another minute or check the settings are correct and the GSM Signals are strong enough If the Control Unit can run and sensors work but cannot send SMS texts please change SIM Card to check tt lf the problem cannot be solved please contact the distributor or manufacturer 13 Warranty 1 2 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide purchasers 14 Trouble Shooting Guide PROBLEM GSM Module initialization failed Automatically Restart Wireless Sensor transmission short False Alarm King Pigeon Hi Tech Co Ltd CAUSE Backup battery with low voltage GSM Module connection loose in transportation GSM Signal is too weak 1 Backup battery with low voltage 1 Wireless sensor with low voltage 2 Wireless sensor used PT2262 IC and incorrect Value 3 Haven t pull out wireless antenna 4 Electromagnetic interference 5 The wireless receiver in the panel with problem 1 PIR Motion sensor installation incorrect 2 Used 24H zones or SOS Zones or Watchdog zone
18. ion 12V IN1 GND IN2 IN3 GND IN4 IN5 GND ING IN7 GND IN8 12V R1 R1 R2 R2 12VDC 1A power output for wired detectors Digital input 1 connect to one wire of the wired Detector Ground point connect to another wire of the wired Detector or 12VDC Digital input 2 connect to one wire of the wired Detector INS Digital input 3 connect to one wire of the wired Detector King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Digital input7 connect to another wire of the wired Detector Ground point connect to another wire of the wired Detector or 12VDC Digital input 8 connect to one wire of the wired Detector 12VDC 1A power output for wired detectors Link Output Relay when the system alarm will close 4minutes ING Digital input 6 connect to one wire of the wired Detector Rated Voltage 3A 240VAC this relay can connect to any other lights or CCTV system as a switch Built in 240VAC 3A rated relay output connect to the device negative electrode Commands Rated Voltage 3A 240VAC this relay is very useful to switch on light when you can not come back in the evening Then some hours you can switch off it Built in 240VAC 3A rated relay output connect to the device negative electrode 4 2 Working Principle Drawing The 110 works with wireless detectors or Wired detectors It can switch on or off one ap
19. le No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com sensors Includes wireless door sensor wireless smoke sensor wireless gas leakage sensor wireless pir motion sensor and so on If configured the AO A7 and DO D3 are the same the system will treat them as the same one sensor 4 Also please check the Resistors value is 3 3M Ohm there re 3 Jumpers 1 5M 3 3M and 4 7M if you select incorrect value the wireless distance usually very short or can not learn to the alarm panel I oe SE L Tj Z fa T A _ a _ _ a a y m e 9 2 Enter the RF Sensor Adding Menu See 6 2 2 1 Add Del RF Parts Select the Zone number press Ok finished it then press OK to select the Normal Type Or Stay Type then following the instruction On the Device means trigger the RF sensor the system will show a code then on the Keyboard The system will ask you repeat the operation so please trigger RF sensor again when you see the Code then press the Enter Button on the Keyboard the system will display Saved OK It means the wireless sensor added to the system Repeat this operation to add other wireless sensors a One time can add only 1 wireless sensor b The Name of the RF sensor can be modified by SMS commands Please see chapter 6 3 9 3 Add Remote Controls to the Control unit Because of both of the S110 and its remote controls are with learning code you c
20. ly P GSM Module indicator registering will quickly flick registered successful will slowly flick w Q Alarm link output indicator when alarm will turn on and last 4minutes means the alarm link output relay closing C Separate output relay indicator when the independent output relay closed it will be on when the independent output relay opened will be off 6 1 2 LCD ICONS Description The S110 uses the icons to descript the present status it will be more user friendly King Pigeon Hi Tech Co Ltd Page of32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Enabled the Timer to arm and disarm function otherwise will not display it Timer to Arm has setup a time point to enter armed mode directly Timer to disarm Has setup a time point to enter disarmed mode directly Enabled the Watchdog zone In the fixed time range if the sensors in the Enabled the system condition report function Will automatically send system condition to the user by SMS otherwise it will not display watchdog zone hasn t been triggered will alarm 6 1 3 Keyboard functions The S110 uses the icons to mark the buttons it will be more user friendly to user cc Enter button dial out and answer incoming e Hang up the incoming Exit and Backspace button _ Up towards button Down towards button t _ Turn Left button in
21. ne Haven t setup SMS numbers Alert Auto dial Numbers Please check the commands with CAPS LOCK and correct format Caps Lock letters in Also please help to change another the SMS Commands GSM Operator SIMCard to test it The End Any questions please help to contact us feel free Email Us Sales Kingpigeon com cn Http www GSMalarmsystem com Http www KingPigeon com cn King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No S1100010
22. note When AC power failure the 12VDC point will no power supply King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com NC Type Connection 12 IN1 GND IN2 IN3 GND IN4 INS GND ING IN7 GND INg 12V R1 R1 R2 RZ 1 The two 12V are power y i source for wired sensors Hr 2 The R1 R1 is the alarm F x link output relay B r 3 The R2 R2 is a seperate at ian output relay which can be ead _ ike TPS Oreo switched ON OFF by SMS Commands _ n 4 The no use inputs must be keep in short circuited by wires ah EOL Type Connections 12V IN1 GND IN2 IN3 GND IN4 IN5 GND ING IN7 GND INg 12V R1 R1 R2 RZ The no use inputs must be shorted by a 2 2K resistor i 2 The Detector must by NC type 22K Eg 3 We suggest connect the 2 2K Resistor inside the detector box in series connection NC Type Sensors NO Type Connection 12V IN1 GND INZ IN3 GND IN4 INS GND ING IN7 GND INg 12 R1 R1 R2 R2 1 We re strongly suggest not use this connection type 2 Inthis connection type all of the wired sensors must be NO and the no use inputs must be free can not be in short circuited mode HNO Type Sensor King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 8 5 Install the Control Unit In
23. nsors directly The no use input please remain them in short circuited by wires Please see 8 4 Install the Wired Sensors and Electricity equipments 2 Zones Attribute definition of the wired zone is the same as the wireless zone 3 The S110 can accept total 8 wired sensors to 8 wired zones each zone can be assigned one wired sensor and renamed it by SMS Command 4 Wired Zone Serial Number Default Zone Name and Zone Attributes Table Zone SN Default Zone Name Default Zone Attribute 24 Hour zones This attribute can not 24Hours zone alarm be modified In arm or disarm or stay s mode once the sensor in these zones 24Hours zone alarm triggered will alarm immediately SOS zone The attribute can not be modified In arm or disarm or stay SOS Help mode once the sensor in these zones triggered will alarm immediately But not drive the siren King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 6 2 2 3 Basic Setting To setup the SMS Alert Number must be cell phone numbers total 3 To setup the Auto dial telephone number total is 5 To setup the time and date information The Format is Month Date Year Press Up Down to setup each item press to move to next item Switch on or off the siren when Alarm occurrence Setup the Report time gap Range 0 240Hours deflaut is 0 will not report Enable o
24. ny Normal 08 intrusion from IF Window Noma 09 intrusion from 2P Window Normal Medical Button Alarm 24 Hour zones This attribute can Gas Leakage Alarm not be modified In arm or disarm or stay mode once the sensor in these Smoke Fire Alarm zones triggered will alarm Watchdog Zone the attribute can not be modified In arm or disarm or stay mode once the sensor in this 15 Watchdog alarm zone triggered in the preset time will not alarm if the sensor hasn t been triggered in the preset time will alarm SOS zone The attribute can not be 16 SOS Help modified In arm or disarm or stay mode once the sensor in these King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com zones triggered will alarm immediately not drive the siren Notice The Additional Panic Button and the SOS button on the Keyboard and remote control is the same attribute with the SOS zone If the Additional Panic Button assigned in 24 Hour Zones once triggered the alarm action will be the same as SOS zone not start the siren 6 2 2 2 Wired Zones Set To setup the wired inputs type To setup the wired input s attribute 1 The Nodes Type NC NO EOL should reference the wired input sensor type The Default is NC and we short all of the inputs by wires if you want to contact wired sensors then please replace the short wires by wired se
25. of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 17 Standby internal rechargeable battery which can last 12 hours 18 Based on the GSM communication network and Operation Menu Display technology apply to wide range situations 6 Settings 1 Please insert the SlMCard firstly and install the GSM Antenna then power on it Also you can insert the SIMCard after you setup 2 All the wireless sensors in the standard package we have assigned to the mainframe already Neednt to learn it again 3 After you power on the mainframe the mainframe will auto detect and display the process It will detect the 8 wired input current connection status and display on the LCD with 8 characters O stands for Open C stands for Close L stands for with2 2K EOL E Stands for not includes the before 3 status If it with SIMCara it will register the GSM Network and display the GSM Signal ICON in the left corner of the LCD 4 Allof the setup can be done by the LCD except modify the Zone name if you need to modify the zone name please see the command list in the related chapter 5 Only disarm by keyboard and modify settings requires password the other operation needn t password The default password is 1234 Enter password then press Enter button to enter the system 6 In standby mode press 3 6 following UP button The system will recovery to factory default settings the password will
26. order to avoid destruction of the Control Unit by intruders please install it in a concealed location convenient to the operator If applicable ensure that an uninterruptible AC power outlet is available near the Control Unit First connect accessories to the Control Unit then the AC adapter 8 6 Install Siren Connect the Siren to the Control Unit and fix them in appropriate locations The Siren should be at least 1 5meters away from the GSM SMS Controller unit if possible more than 3meters is better T Siren Strobe Siren 9 Add Wireless Sensors to the Control Unit Some wireless sensors must be coded by manual as below 9 1 step some wireless sensors needn t coded by manual because of we will use the learning code sensor The learning code wireless sensor you can omit the 9 1 step can be learned to the system directly like the PIR 100B and DM 100A The Wireless sensors in the package box are pre coded prior to shipping The Max Quantity of RF sensors is 16 if you need add more then you can set the wireless sensor with the same jumper Add additional wireless sensors to the control units please help to see below 9 1 Prepare the RF Sensors of PT2262 IC Code 1 Prepare the RF sensors Open the back cover of the Wireless sensor carefully 2 Locate the IC boards black jumpers labeled AO A7 and DO D3 3 Configured the AO A7 and DO D3 different from each wireless King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 Fi
27. pliance by SMS command Please see below Independent Output Relay Can switch on or off by SMS R2 King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com O Wired or Wireless C Smoke Detector E EEA ER C Fire Detector i poceeseseeeee Motion Detector s Glass Breaker I I i Antenna 1r C Magnetic Detector SMS Control Light Control Unit Sto 5 Features 5 1 The advantages of the GSM Alarm System S110 1 Two way Voice communication or wiretap are available 2 LCD displays the entire setup menu 3 Armed Partial Armed At House or Stay Disarmed SOS are available 4 Armed delay alarm delay siren work or not more other functions are Programmable by user 5 Watchdog 24Hours Zone SOS zone are available 6 Using ICON to display armed Partial Armed Disarmed Power status Siren status and GSM Signal status 7 Auto detect and report GSM Signal Jammer alarm SMS Switch is available 8 User friendly Icons for LED indicators LCD and functional Buttons King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com 5 2 Functions amp Features of the GSM Alarm System 1 2 16 GSM Frequency Dual Band 900 1800MHz Quad Band is optional 850 900 1800 1900Mhz
28. r Disable the alert function while the AC power Is failure more than 30 minutes Setup the delay time after armed the system by remote control or keyboard Optional 0S 20S 30S 60S 90S Default is 30S Setup the delay time after any sensor triggered Optional 0S 20S 30S 60S 90S Default is an 1 The SMS Alert number is for receiving the alarm SMS Message The Auto Dial Telephone number is for receiving the calling Please help to try adding country code or removing country code when you can not receive the call or SMS Because of different GSM Operator with different communication protocols Our system is with the international communications protocols 2 The Auto dial Tel Number can dial to the S110 6 tones later can wiretap the system site Before 6 tones if somebody answers the calling then can create two way voice communication The other telephone number can call in the S110 if nobody answer the calling then can not wiretap the system site if somebody answers the calling then can create two way voice communication King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com For example In China the country code is 0086 please note do not write 86 The user cell phone number is 13570810254 and has been assigned as a SMS Alert number the simcard number in the panel is 113512345678 Problem 1 Alarm but
29. tegrated Lcd Menu display and Computer technology When any sensor activated it will Call amp Send SMS to owner s telephone immediately The GSM Alarm System 110 with user friendly design idea all operations and settings are visual and intuitive What you need is a SIMCard which supports Call ID function 2 Safety Directions Safe Startup Do not use GSM Alarm System when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM Alarm System and influences its performance Avoid Use at Gas Station Do not use GSM Alarm System at a gas station Power off GSM Alarm System it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal screening by covering the King Pigeon Hi Tech Co Ltd Page of 32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Waterproofness The product is not waterproof Please install it at dry places and keep it dry 3 Standard Packing List Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2 Wireless P
30. the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means setup 008613570810254 to instead of the 13570810254 Problem 2 The user number can receive the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the simcard number in the alarm panel Means send sms commands to 008613512345678 to instead of 13512345678 Solution 3 When you use cell phone dial another one what number it will be displayed then you can set the displayed number as dial numbers when you use cell phone send SMS to another cell phone what number it will be displayed then you can set the displayed number as SMS Alert number just use the 00 to replace the 3 If Switch off the siren then all alarm raised will not drive the siren if switch on the siren then when the system alarm will drive the siren for 1 minute except the SOS help caused Default is Switch on 4 If setup the Report Time Gap the system will periodically send GSM Alarm System in good working condition to the first SMS Alert number This is very useful for long time use the system Default is 0 Means will not report the system condition 5 If enable the power failure alert function the system will send SMS AC Power Failed 30Min to the first SMS Alert numbers after the AC power failure 30minutes if the
31. xample 1111DD When the Password is 1111 Page of 32 Ver 1 0 File No S1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com XXXXEE Return SMS The Output relay status in the Return SMS is the independent output relay status It is not the alarm link Output Relay Status 8 Installation Before installing the control unit and sensors and sirens please help to test the system firstly including wireless sensor power supply gsm signal etc Please ensure the wireless sensors and electricity appliances from the mainframe more than 3 5m 8 1 Insert SIM into Control Unit and install the GSM ANT In the backside of the control unit please install the GSM SIM card The GSM ANT must be Vertical installation to ensure it in good working condition 8 2 Install the Wireless Magnetic door window sensors Magnetic door window sensors signal the Control Unit when the two parts separate by more than between 1 5 to 3 0cm King Pigeon Hi Tech Co Ltd Page of32 Ver 1 0 File No 1100010 A Top Safety and Protection Solution In The Worldwide www GSMalarmsystem com Low Voltage Indicator Double Faced Tape Work Indicator In some circumstances an Infrared beam fence is more appropriate than magnetic sensors i e veranda picture window balcony boundary wall e t c x gt oe A ZEN G Bi Fa a i FEPER TTT Wireless glass break sensor can
Download Pdf Manuals
Related Search
Related Contents
13 eagle eye gold catéter para ecografía intravascular X-PD-BM 01-02-eng Cover.pmd Chapter 1: Getting Started Turnitin Instructor User Manual André Pappathomas COMUNICADO - Brisa Concessão 取扱説明書 2 3 Alguns serviços e aplicações podem não estar 01-PNY catal anglais Pando P-416 Montage du boîtier pour constructions massives Copyright © All rights reserved.