Home

Installation Manual - Smart Solutions in Security

image

Contents

1. 25 19 RS 485 communication CONNECTION 26 20 Change communication mode RS232 485 27 21 Change communication rate ER ee RR ee RE RR Ee Pere ee 27 22 Change controller address 28 23 Convert RS 485 to TCP IP KS 1012 24 RS 29 24 Connect with router or computer KS 1012 24 IP 29 25 RS 232 communication connection 30 26 Alarm extension board 4 relay module 31 27 Notes for installation 32 28 Wire Requirement U Uu nennen nnn arca ron eeuw BA 323 29 Trouble Shooting ici ric ER KN C i Rec 34 ALL rights reserved AAT Holding sp z 0 0 2 Standard Access Controller Installation manual Summary Introduction KS 1012 24 RS IP series controllers were designed and developed for use in access control system It is a high tech product series which integrate infor mation management computer control and smart card technology With indus trialized design the controller adopts dedicated four layer and high end CPU and all components adopt original binding chip All these characteristics contrib ute to the high performance and reliability of the product KaDe Premium the software for KS 1012 24 RS IP controller series is a
2. Installation Manual STANDARD CONTROLLER KS 1012 RS KS 1024 RS KS 1012 IP KS 1024 IP asKKaDe VERSION 1 0 enk Holding sp z 0 0 lawska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 www aat pl Standard Access Controller Installation manual CONTENTS A tende herten banned 3 2 Controller technical data KS 1024 RS IP 5 3 Controller technical data KS 1024 RS IP 6 4 System circuit diagram KaDe Premium 7 5 Controller module 5 1012 3 6 Controller module KS 1012 IP 10 7 Controller connectors description KS 1012 RS IP 11 8 Controller module KS 1024 IP 13 9 Controller module 5 1024 5 15 10 Controller connectors description KS 1024 RS IP 16 11 Installing the controller in the housing supply 18 12 Power supply Connection Ad 13 Reader connection nemen ee ee 22 14 Electric lock Connection 23 15 Door contact and exit button connection 24 16 Emergency exit button connection 24 17 Alarm input output connection 18 Clear communication password buttohn
3. BA MH geer EWE VERE ir iw ALIE war WE mr Pd MIT S in KS 1012 RS controller module ALL rights reserved AAT Holding sp z 0 0 A IH e 351 INH Se zi HA INH PELI 005600000000006000000000 Standard Access Controller Installation manual Address and RS 242 Baud Rata Communication Interface F 232 485 Convert 485 Communicaton Indicator C Alarm input 4 485 R3 485 GND Alarm put 3 00 GN Alarm nput2 z a p Door 1 Electric Lack Output 2 Daar 1 Daar n HULL dy magnet Output NULL GND E w t Daar magnat 1 3 i A 1 NEEEEEEEEEEEEE Exit Button 1 3 2 HULL 2 Alarm 2 ZBLUZ Output E Reader 2 2D1 Interface uu E gt Alarm 3 RO 5 Output 2RD E NULL m Alarm 4 1BUZ Output E Reader 1 101 Interface 100 IRD Power Supply 1RD lo Reset Button Clear Comm Reader Interface Alarm Extension nication Password Button OK Light Board Interface EE EE KKEEN All output ports are of default setup User can self define the ports as needed KS 1012 RS controller module 1 1 I ALL rights reserved AAT Holding sp z 0 0 Standard Access Controller Installation manual TCP IP Communication Interface Alarm input4 Alarm input 3 Daar 1 Elactric Lack Output Alarm input 2 du suam pg Alarm input 1 Daar 1 Daar magnet
4. 14 Before connecting the power supply controller to perform all the necessary instructions below 15 Computer connection can be done using RS232 RS485 and built in con verter or IP port 16 Connection to the computer using the RS232 port should not exceed 15m 17 Connection to the computer using the RS485 port should not exceed 1200m 18 To the RS485 bus can be connected to 32 controllers Each controller must be set to a different address 19 Please do not touch components with bear hand since body static electric may damage the components 20 When installation is completed please check Is the connection correct Is there any short circuit or open circuit Is the back of controller completely separated from conductive materials 21 Please do not dismantle or change the controller chip Incorrect operation will damage the controller In case of product failure or any technical problem please contact with supplier Wire Requirement Cable Direction Wire Standard PC Switch 8 core screen 100m Network Controller twisted pair wire UTP 5 Switch Controller 8 core screen 100m twisted pair wire UTP 5 PC Switch 485 Standard Serial Port Wire 5m Including Converter 485 Controller Products 485 Converter Controller 8 core screen twisted pair wire or 2 core screen ca ble 2x0 75 1 0 Header Controller 8 core screen 60m twisted pair wire Electric Controller 4 core screen cable 150m 4x1 0 Exit Button Controller
5. Note For 485 communication please adopt hand in hand connection instead of star type connection Remark Wire UTP 5 8 core screen twisted pair use two pair Distance 800m Theoretical distance is 1200m In practical application distance is around 800m To prolong the distance repeater should be added Converter Active converter Passive converter should be avoided since it may cause communication problem Jumper Jump to 485 position Suggestion USB converter and passive converter are not recommended in big ger installation 485 communication light RX and TX will flash only when controller is in communication state When RX and TX connection is reversed RX light will be Light all the time Yellow light Hardware V1 2 or above is supported only ALL rights reserved AAT Holding sp z 0 0 26 Standard Access Controller Installation manual Change communication mode ED 525935 etste 5757 TTTT en Ro 232 Remark Controller can connect with PC via RS 232 or RS485 trough converter Make sure JP1 is on the right position Do not change communication mode by hori zontal jump Change Communication Rate sos 595096 99099 935099 9950 No 8 dial switch for rate change 19200bps 9600bps Remark KS 1012 24 RS controller series can connect with computer by 9600bps and 19200bps communication rate default setting is 19200bps Controller baud rate must be the same as the baud rate of the seria
6. 2 core screen cable 150m 2x0 5 Emergent Exit Button 2 core screen cable 150m Controller 2x0 5 Controller Extension 6P Connection Wire 20cm Including Board Products ALL rights reserved AAT Holding sp z 0 0 33 Standard Access Controller Installation manual Trouble Shooting Reader can not read card There are many reasons for this problem User need to check 1 When present card is there any sound Is the LED on 2 Please check the connection Is there any short circuit or cut Is your reader output format correct 3 Check the Register Card function of software Is the card information re ceived 4 Please check controller voltage DATAO and DATA1 Voltage above 4V indicates the reader dysfunctions while lower than 4V indicates controller dysfunctions Software can not connect with database 1 User is not authorized to write the database Go to WINDOWS TEMP change the read authorization to EVERYONE everyone or install new system 2 Module problem user need to install again 3 Operation system fails re install the system Lock can not be closed Connect the lock with12V power supply directly If lock works then test C and NC port and check whether there is any short circuit for fail secure lock e Door can not be opened by presenting card 1 Make sure reader connection is correct 2 Check whether the card number is in card record 3 Check validity of the card 4 For valid card is
7. communication rate unit is bit s bps Two devices can communicate only when they have the same baud rate Dry Contact A type of switch input mode without any voltage or current Controller Address On the same bus each device must have an unique identification code KS controllers adopts address code as identification code Reset Switch The reset switch is used to hot recover the controller during debugging or in case of special situations The hot recovery will neither affects the storage of controller nor user setups Alarm Interworking Different inputs can control different exterior devices by connecting to different outputs Here is one example reader triggers DVR to snapshot or video re cording Controller Failure Controller does not respond to any input and output or only responds to part of input output ALL rights reserved AAT Holding sp z 0 0 4 Standard Access Controller Installation manual KS 1012 RS IP Controller Technical Data or function name or function description Buffer capacity Alarm buffer 20 000 Electrical parameter O OO Environment parameter Communicationports 6017777777 nputs EN TT oo Access level o ALL rights reserved AAT Holding sp z 0 0 5 Standard Access Controller Installation manual KS 1024 RS IP Controller Technical Data or function name or function description Buffer capacity Alarm buffer 20 000 Electrical parameter O OO Envir
8. sC Alarm 1 ERA Output NO Alarm 2 eec Output 6 0 Alarm 3 Tac Output TMO ac Alarm 4 auc Output 14 Alarm input 4 Alarm input 3 Alarm Input 2 Alarm input 1 NULL Door magnet 2 Exit Button 2 Door magnet 1 Exit Button 1 Paadard Header Header Raadari Standard Access Controller Installation manual Address and Baud Rate Communication Interface 232 485 Convert i e 485 Communication Indicator M a b i i NE m E 4854 n RS485 E Jumper war Door 1 Elac 3 INC ved 180 E a m d Daar 1D 2 d ZNC magnel Output k 30 M Daar 2 Elaciro Lack Output zm E 3NO m ac Z ANC Daar 2 Daar ANO magnat Output a R EMC Alarm 1 END Output d ENG Alam2 END Output r3 s 7C E 7HE Alarm 3 Output 7NO E E Alarm 4 r d 8NC Output t BNO 5 Pawar Supply FERRE 0 GND o BE Raadar Interface Resal Button Clear Commu OK Light nicabion Password Button Alarm Extension Baard Interface NEP Pais are of default setup User can self define the ports asneeded KS 1024 RS controller module ALL rights reserved AAT Holding sp z 0 0 15 Standard Access Controller Installation manual Controller connectors description KS 1024 RS IP two door two way FUNCTION Symbol Symbol FUNCTION Input 4 ALR4 4854 Communication Input 3 ALR3 Alarm inputs GND ic e uvm Ses i
9. the LED on and relay sounds when presenting card If both are ok check lock connection and lock state 5 If card is indicated as invalid reasons are a The card is illegal The card is not registered and assigned by the software User need to assign the card to access group b The card is an expired temporary card Temporary card can be used within certain period only C You are using card password mode d Your access group are not authorized to access this reader e This reader needs First card open Any other card can open the door only after First card is presented to the reader f This reader needs multi card open g Card is not detected present the card again h Your card is damaged make sure there is no fold no burn and no magnetization I The reader has anti passback function User can not present card on the same reader continuously j This reader is used for attendance only K System sets All Day Forbidden I Remote control is applied on this reader ALL rights reserved AAT Holding sp z 0 0 34 Standard Access Controller Installation manual Card present time missed in the record 1 Database is not compatible 2 Controller time is incorrect Card present Record disappears 1 Memory is damaged 2 Record overflown 3 History record is covered by new record 4 Download record before upload History record is cleared TCP IP converter problem TCP IP converter should
10. 8 Alarm relay eNC Output 4 Null NULL LED or buzzer 1BUZ Wiegand 1 Door 1 12V WER Entry reader Controller Trev Reader power 12V port power GND 12V Reader power 12V GND Controller power ALL rights reserved AAT Holding sp z 0 0 11 Standard Access Controller Installation manual Controller connectors description KS 1012 RS IP two door one way ALR4 485 485 Input 4 Communication G 2 G G 2 U U port Alarm inputs Relays 20 30 Door 22 Door contact GND nput 3 ALR3 GND nput 2 ALR2 G U Input 1 ALR1 D S1 GND 1C 1NC 1NO 2C Door magnet input ANC 2NO 3C G Exit button AN1 D S1 Exit button input Door magnet input Door 1 G U 3NC 3NO 4C ANC ANO Door contact Exit button AN1 Relays Door 12 Exit button input Null NULL Door 2 O 5NC Alarm relays CN o O O Door 1 12V 12V GND GND Entry reader Reader power 12V port Reader power 12V Controller power ALL rights reserved AAT Holding sp z 0 0 Lock relay Door 1 Alarm relay Door 1 Lock relay Door 2 Alarm relay Door 2 Alarm relay Output 1 Alarm relay Output 2 Controller power 12V FUNCTION Communication port RS 485 12 Standard Access Controller Installation manual nunt Fi CE RUTA TEE rre X an TEA TETE oh a IDE E ES
11. A 2 JA gt C als el 8 e 2 8 k O DL Remark Wire Two core supply power cord Power supply Voltage 12V Current gt 2A Distance Within 100 m Note Please turn off power supply before start connection Please also note positive negative connection Electric lock and alarm outputs working principle Relay Normal State Relay Trigger State 4 4 Relay Relay NC Etectrictock INC nente OM OM NO COM and NC short circuit COM and NC cut COM and NO cut COM and NO short circuit Remark NO Normal Open normal open contact NC Normal Close normal close contact COM COMmon common contact ALL rights reserved AAT Holding sp z 0 0 21 Standard Access Controller Installation manual Reader connection Exit Button Door Magnet Input 2 Lock state control wire can be connected with LED or BUZ am Reader Interface Indicator Reader Remark Wire 6 core screen wire or FTP 5 8 core screen twisted pair Distance Distance between controller and reader lt 60m Note Reader should be of the same format as in the software Reader Connection Indicator When user presents card to the reader RD OK light will flash one time only when the connection between reader and controller is correct and controller interface works properly otherwise RD OK light will not respond Hardware V1 2 or above is supported only BUZ LED lock state control wire can be c
12. ESTEE peatg dik M Ihi LS E 2 raz 7 E d 5 da BI eo E baz 2 i ca a e w e o dy 5 Hmmm HTTP Ap rel el edd in SZ LLLLEL a REI DIE un m II sn a N FIETETL KH lom Hal m smal KS 1024 IP controller module ALL rights reserved AAT Holding sp z 0 0 Alarm input Alarm Input 3 Alarm input 2 Alarm input 1 HULL Daar magnat 2 Exit Button 2 Daar magnat 1 Exit Button 1 Header 4 Insarfaoa Header 3 Insarfaoa Raadar 2 Insarfaoa Raadar i miariacu Standard Access Controller Installation manual mduy ue py Jon ura is z E am m D m E ra sunu WIG IE 3 KIEJ JEJU JBDENH TCP IP Communication Interface Bag Indes wer MEd Tn LIE pz Had agua zs BOE JOU A pddng A CM 8 0000000 HET o Header interface Reset Bulttan Clear Commu Alarm Extension OK Light A A AA AA E ee E E ee ee ee ee E FS EE E E E E w E E ee E A W All output ports are of default setup User can self define the ports as needed r nication Password Button Board Interface KS 1024 IP controller module ALL rights reserved AAT Holding sp z 0 0 Daar 1 Elaciria INC Lack Output Daar 1 Daar 2NC magnat Output NO 32 Daar 1 Elactric Jc Lack Output AD Daar 1 Daar RE magnat Output ANO
13. ORRELE AGE Warning F a S a fe ergen or realn E loudspeeker Electric Lock E Power suppl 55 interface AE EE Controller Remark Wire 4 core wire Note A1 is public terminal Normal situation A1 A3 is pass A1 A2 is open When glass is broken A1 A3 is open A1 A2 is pass ALL rights reserved AAT Holding sp z 0 0 24 Standard Access Controller Installation manual Alarm input output connection Alarm Light O U i BS E LA LA LU k o Definition of interfaces on this wiring diagram is default setup User can define the inputs and outputs as needed Remark Wire 2 core Interface Switch input Note The actual alarm input type must match with software setup Clear communication password button I Controller Fa r i m k uunnun LJ ET k Reset Button Clear Communication Password Button Remark Instruction In case communication password is unknown user can press the button to clear the communication password ALL rights reserved AAT Holding sp z 0 0 25 Standard Access Controller Installation manual RS 485 communication connection KaDe COMMUNIC ATION CONVERTER EIA EZ RS 485 422 TED wan PAR D D e RS 485 Communication Converter Lit M umper C 485 Communication Indicator gt i Controller IO to converter
14. Output Mg 00 ue p EE Door magnat 2 Exit Busan 2 Daar 2 Electric Lack Output mdu useR MOT WD T 1163 t em Doar magnat 1 d n L a ime Exit Button 1 Daar 2 Daar magnet Output 1 Raadar2 Alarm 1 Interface z E Output R m Alarm 2 d Oulput i n Raadar i E interface A Fowar Supply d m T Reset Butllen ZE ear Cam mu 4 Reader Interface I Alarm Extension nication Password Bullan OK Light Board Interface En ME EE mm m m e All output ports are of default setup User can self define the ports as needed D d KS 1012 IP controller module ALL rights reserved AAT Holding sp z 0 0 10 Standard Access Controller Installation manual Controller connectors description KS 1012 RS IP one door two way FUNCTION Symbol Symbol FUNCTION Input 4 ALR4 ommunication Communication port port RS 485 Input 3 ALR3 Alarm inputs Input 2 ALR2 m Lock relay Door 1 Input 1 ALR1 Relays 1NO TL n Alarm relay Door 1 NO Door contact Exit button input AN1 Exit button LA O Alarm relay 3NC Output 1 N O D O Alarm relay Alarm relays Output 2 Null NULL 2BUZ 2D 2D0 2RD 2RD N N D Ul A CJ O O LED or buzzer Wiegand 1 Wiegand 0 Outputs con Door 1 trol O Alarm relay Output 3 U N 5NO O Exit reader port Reader power 12V Reader power 12V O
15. ader power 12V RD P LED or buzzer 1BUZ Wiegand 1 Wiegand O Door 1 Entry reader port Communication port Relays Door 1 Relays Door 2 Relays Door 3 Relays Door 4 Controller power ALL rights reserved AAT Holding sp z 0 0 Symbol 485 485 GND 1C 1NC E N O 2 NJ O 2 N lt O E O 1NC 1NO N R 2NC N OLO NC N E N Ele Olo ANC 2NO C 1NC 1NO 2C 2NC 2NO 1 12V 12V N GND U FUNCTION Communication port RS 485 Lock relay Door 1 Alarm relay Door 1 Lock relay Door 2 Alarm relay Door 2 Lock relay Door 3 Alarm relay Door 3 Lock relay Door 4 Alarm relay Door 4 Controller power 12V Standard Access Controller Installation manual CRW WSL WW repuso LLN LEQ a jou og E yn se g u dep jou og Roum vorz ueno xey NAS osn opk AGEL AGEL esn qpugjs uopejnBas eBeyo Seu jurjsuo9 apeg ploV pea7 ejgeeBreydor UY 4 Ly 4 GU rA o ALM i o e 2008008000060 eege AE 1012 RS IP Supply power and metal cabinet for KS MAC Add 00 D1 EF ea AE txs LOGA Jou OQ PEED yfin tz5 a u temp po tQ KOU varz quaun buf v eyy ASA PP En opk ABEL ASTE osn Loge uopemBa oBryo ofluruo obmo jumsuo Aisyeg ejgeoBseysor uve ne Lag Sn
16. az RED T BE Sang GE Fi HET SEES EU Beet RRR RR ao FE YAYAZLILILXIXLIILIYIYYILIY Supply power and metal cabinet for KS 1024 RS IP 18 ALL rights reserved AAT Holding sp z 0 0 Standard Access Controller Installation manual Installing the controller in the housing Controller module must be installed in a dedicated buffer power supply housing proper for the controller model There are two dedicated housing AAT 2A designed for controllers KS 1012 RS IP 2 readers AAT 3 5A designed for controllers KS 1024 RS IP 4 readers Power supplies installed in these enclosures are performance as a symbol in the name of 2A and 3 5 A This performance allows the power supply controller mod ule 2 or 4 readers and 2 or 4 electric locks even electromagnetics lock for cur rent consumption 500mA The housings are designed to be installed inside the battery with a capacity 7Ah in vertical position in a special holder as pictured on the next page Connections inside the case output voltage 12V connect the terminal controller terminals TAMPER power connector into an available detector line input controller to the terminals at the edges of the controller attach cables from readers locks keys and door status sensor door magnet red and black cable from the power supply connected to the battery terminals 230 VAC mains plug to power cubes on top of the housing through the exist in
17. be applied with Anson software In case of data transmission error user can adjust converter transmission delay Fail to connect controller via RS 485 communication mode Converter applied should be active and equipped with signal amplifier In addition some types of USB 232 converter may not be compatible Theoretically communication distance of RS485 is 1200m but its practical distance is around 600m because of interference w i r e type load capacity and so on It is not recommended to connect too many devices on a RS 485 bus The prima quality connected is around 20 units To connect more devices user can add a 120 ohm resistor between 485 and 485 Screen twisted pair is the best choice Moreover user should also note that the communication rate of software and hardware should be the same Connection of RS485 communication Serial connection should be adopted Time is incorrect and can not open the door Validity of card is related to time Due to component failure aging and interference etc controller time may differ from PC time It is recommended that administrator adjusts time periodically every 2 3 months Red light is still on after magnetic lock closed This is caused by the mismatch or gap between lock surface and lock core Software password is forgotten If possible please send us the database for recovery Real time monitoring does not work Firstly please edit an E map and add some monitor
18. e line should be 1 m and from transmitting devices 8 m 5 The controller should be powered from the line power supply with backup bat tery with parameters 12 VDC 2A or 4A This takes into account any power door locks with the same power supply 6 KS 1012 24 RS IP series are compatible with devices from other suppliers However it is recommended to study the spec of the devices before connecting them to KS series In order to avoid possible malfunction of KS series the reader output format power supply voltage power consumption and max current etc should be compatible with KS series 7 KS series are MCU based system which work 24 hours a day The device should not work nearby environments of strong electromagnetic interference and large or high voltage electric devices 8 Check the grounding situation before installation 9 485 bus electric lock wire reader wire 220V power supply wire etc should not go through the same wire or wire case 10 Cable standard should be in accordance with or above local standard 11 When control multiple devices please ensure the uniqueness of device ad dresses 12 Star connection should not be adopted to 485 bus in order to avoid unex pected communication problem 13 Please make sure KS series are powered off before carrying out any opera tion Hot plug in out is prohibited ALL rights reserved AAT Holding sp z 0 0 32 Standard Access Controller Installation manual
19. g fuse After completing all connections enable the supply voltage 230 V and validate the operation of the controller Housing has a removable door which can be removed after unscrewing the cable mass Housing is closed on the two bolts screwed on the right edge Opening of the sensor housing is monitored sabotage Connect it to the free in put detector line in controller and activate the program so that the alarm was generated Look at diagram on next pages for details ALL rights reserved AAT Holding sp z 0 0 19 Standard Access Controller Installation manual Joyeipey DEN SIo O UOO DIEDUEIS SU O Ajddns 1aMod apisui weJbelp DUIM UWZ Acl Men eg Jeduiej DADB VSE Z ACI Jemod Ajddns VEICLOL SA a n POW 1 OJJUOO SU SO Qmm AROS OVAL V OV OV NOEZ AOS C VY DADIB IASAD IDI jnpow g YH y s ood 20 ALL rights reserved AAT Holding sp z 0 0 Standard Access Controller Installation manual Power supply connection Controller D O U DN li c
20. l port on software ALL rights reserved AAT Holding sp z 0 0 27 Standard Access Controller Installation manual Change controller address DIP switch Number1 7 Adjust identification address Remark Change the identification address of DIP switch SW1 This setup is to KS 1012 24 RS The controller address can be set as the following Note Default address is O Every bus can connect 32 controllers Every controller address must be unique ALL rights reserved AAT Holding sp z 0 0 28 Standard Access Controller Installation manual Convert RS 485 to TCP IP KS 1012 24 RS IL En TCP IP Converter Router Management Server Remark Wire 3 core screen wire controller converter or 8 core screen twisted pair controller converter Jumper Jump to 485 position shown in following picture Input Voltage DC12V Connect with router or computer directly KS 1012 24 IP EE aman Management Server Remark Wire 8 core screen twisted pair wire Communication Rate 10 100 M self adaptive Web requirement Direct Connection crossing self adaptive Network Length 100m Note Controller and LAN must be in the same network ALL rights reserved AAT Holding sp z 0 0 29 Standard Access Controller Installation manual RS 232 communication connection DBS Hole DBS Pin Management Server Remark Wire Standard serial port wire Distance Within 15m Jumper Connect 232 position ALL rights re
21. mo Tl ac lm ar ic Lock relay ANS Communication port RS 485 NJ Door magnet input Door 2 Exit button input Exit button Door magnet input Door 1 Exit button input Exit button LED or buzzer ABUZ Door 2 Wiegand 1 Exit reader port Wiegand 0 Reader power 12V NJ R Alarm relay 2NC Door 2 N E OLO Alarm relay Output 1 NTN NJ 212 lt Z O O NJ O Alarm relay Alarm relays Output 2 Outputs control E O Reader power Alarm rela Reader power 12V RD P 1NC Output 2 LED or buzzer 3BUZ Door 2 1NO NJ O Wiegand 1 Entry reader Wiegand 0 port LED or buzzer 2BUZ Door 1 Wiegand 1 Exit reader port Wiegand 0 Reader power 12V Reader power Reader power 12V P 1 0 Alarm relay Output 4 NJ Z O 2NO 12V 12V Controller power LED or buzzer 1BUZ Door 1 Wiegand 1 D Controller 12V Entry reader PRA GND Wiegand 0 port GND ALL rights reserved AAT Holding sp z 0 0 16 Standard Access Controller Installation manual Controller connectors description KS 1024 RS IP four door one way Reader power 12v RO Alarm inputs Door 4 Door contact Exit button Door 3 Door contact Exit button Door 2 Door contact Exit button Door 1 Door contact Exit button Door 4 Entry reader port Reader power Door 3 Entry reader port Door 2 Entry reader port Reader power Re
22. onment parameter Communicationports 6017777777 Inpets N outputs ooo Access level o ALL rights reserved AAT Holding sp z 0 0 6 Standard Access Controller Installation manual urnrur rq oq ev UIE ISEIP MIMI WIJS S SU FZOL SY SH CLOL SM ze 19jo3uo2 1 y Br 023 02 n Jape 94 nm Japesy 2 01 O H DP M 09 9 Jo pes H dl cOL S M di clLOl S Je OJ U09 Je OJJU0 S8V dO L D NVM NV 1 Gep cec SU eM JeNeS UOIEISAJOM UI Si9 lonuoo ZE o dn GYS SYIOMJON 0Z O dn Jopeo DIS SJ9 043u OO pz 0 dn UIUPY SJope 81 96 op dn Aoede woj SAS Z6Z SM eaa NVM NV 1 ALL rights reserved AAT Holding sp z 0 0 Standard Access Controller Installation manual i TELITA con LDL PROPER Eey TTL qna en ET VI OU Ge El TEER ALA d IT g AF CRE um ert de LEE m im af m r mun LULU titititi NE J mm BENT M mt e T ve RIEDER AA MH 1 er Le 1 DE Ae Ve fa m c 3i x ncn di ILL eite BE ag n 1 34 10H Zaw Hin TEPEE tart 2 je e T J g LIE 41 de Sin n EEE 2 L el 1 TE gt wm va ET KEN i4
23. onnected with LED or BUZ When lock is not closed BUZ will beep or LED will be light until the lock is closed Hardware V1 2 or above is supported only ALL rights reserved AAT Holding sp z 0 0 22 Standard Access Controller Installation manual Electric strike NC type connection Electric Strike Fail safe D o 4 D pur E Es a e UN fee D O DL IE 3 rit orirolFoerd Alr rr Casp ul Puri Po wer Supply ria face x Connector Door 1 or 2 Controller 2C Remark Wire 2 core power supply wire Power Supply DC12V Distance Within 150 m Suggestion electric lock and controller power supply should be separated and electric lock current should be less than 1A Electromagnetic lock NO type connection Electric Lock Fail safe Power Supply Interface Controller Remark Wire 2 core power supply wire Power Supply DC12V Distance Within 150 m Suggestion electric lock and controller power supply should be separated and electric lock current should be less than 1A ALL rights reserved AAT Holding sp z 0 0 23 Standard Access Controller Installation manual Door contact and exit button connection Controller Door magnet Exit Button Remark Wire 2 core screen wire Distance Within 150m Note Input type of exit button and door magnet should be the same as in the software Emergency exit button connection EMERGENCY DO
24. ors one way 2 readers ports TCP port 20 000 cards 50 000 events 20 000 alarms Standard controller two doors two way four doors one way 4 readers ports TCP port 20 000 cards 50 000 events 20 000 alarms ALL rights reserved AAT Holding sp z 0 0 3 Standard Access Controller Installation manual Installation Steps 1 1 Switch off all system power supplies 1 2 Ensure correct components connection 1 3 Connect the system in accordance with the wiring diagram Please turn off computer and power off before connecting controller with computer 1 4 Change controller communication mode 232 485 mode communication rate and communication address 1 5 Check the connection again 1 6 Switch on the power supply and start computer Definitions and Terminologies Wiegand protocol Wiegand protocol is an interface protocol by which the ID identifying device sends data to access controller Wiegand protocol is an uni directional protocol and is downward only It is composed of two data channels Normal Open Under normal situation the common end C and Normal open end NO of out put or input interfaces are not connected Normal Close Under normal situation the common end C and Normal open end NO of out put or input interface are short circuited Fail safe Fail secure In Fail safe mode the lock keeps locked when power off In Fail secure mode the lock keeps locked until power on Baud Rate A kind of
25. position in the software Secondly ensure the connection between controller and software For detailed information please refer to user manual ALL rights reserved AAT Holding sp z 0 0 35 AAT Holding sp z o o e ul Putawska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 Warszawa e mail aat warszawa 8 aat pl www aat pl
26. power ful control and attendance management system KaDe Premium is a self owned technology and new generation one card solution smart management system Based on one card solution structure more functions are added on current access control system The system supports Batch Operation Self defined Extension Output Automatic Download during Different Times Various Door open Modes in Various Time Sections and Dismiss Activate Security Func tion etc KaDe Premium can manage access group setup display and record all real time event data It can display the following information card holder name photo event time door address and event type working hours work over time read card during non working hours invalid card and so on Moreover in case of unexpected event KaDe Premium can trigger alarm and snapshot KaDe Premium can also work with building automation CCTV monitoring guard against theft fire control and alarm and so on KS series controller KS 1012 RS KS 1024 RS KS 1012 IP KS 1024 IP Notice KS 1012 24 RS IP controller series only work with KaDe Premium software Controller description Standard controller one door two way two doors one way 2 readers ports RS232 and RS485 port 20 000 cards 50 000 events 20 000 alarms Standard controller two doors two way four doors one way 4 readers ports RS232 and RS485 port 20 000 cards 50 000 events 20 000 alarms Standard controller one door two way two do
27. served AAT Holding sp z 0 0 30 Standard Access Controller Installation manual Alarm extension board Alarm 1 Alarm 2 Alarm 3 Alarm 4 Output Output Output Output ml E m 19 04 u02 10 404 Alarm Extension Board Diaqram 49 7333 33 11 89928 5535 Ku C4 Cd mm el m MY M mm un vore UN won pigog uoisu 1x3 is8895 59359 Ub isa 3555 sg Controller Connect Alarm Extension Board with Controller Remark Wire 6P connection wire Standard wire Direction Interface insert mode Note When output of controller is not enough user can adopt alarm extension board to connect with extra devices such as alarm light alarm bell and DVR etc Advice Please do not define one alarm output to different functions ALL rights reserved AAT Holding sp z o o 31 Standard Access Controller Installation manual Notes for Installation 1 Before installation please read this manual for detailed product functions and installation conditions 2 Installation of the controller can be performed only by qualified personnel with the appropriate certificate authorizing the installation and servicing of such equipment 3 The controller should be installed inside the protected area at a temperature above 42 C and normal humidity 4 Controllers should be located so that the minimum distance from the cables and high voltage devices and other devices that generate electrical noise was 2 m The minimum distance from the telephon

Download Pdf Manuals

image

Related Search

Related Contents

Samsung M197BNR Инструкция по использованию  Bedienungsanleitung  Oregon Scientific RMS600 / RM600A Radar Detector User Manual  1.INT-260 SRC Programmateur Manuel de l  Hitachi FD2 1590 User's Manual  CA Infrastructure Management Data Aggregator  Samsung CE2777N Microwave Oven User Manual  安全対策  IP Office Release 7.0  1 Your mobile .................. 9 Tools ........................ 2  