1. 8 ParaStatus Num COM 30 Setting receiving data number Communication Word data number that Master will receive from the inverter through communication is set v Inverter can send inverter 8 Words for the maximum v You must set exactly same with the number of receiving data of Master program 9 Para Status 1 8 COM 31 38 Receiving address 1 8 setting v Inverter address through which inverter will receive data from Master is set v It is possible to set inverter address for communicating from COM 31 to COM 38 but inverter sends Master data as the number of COM 30 ParaStatus Num through communication 10 Para Ctrl Num COM 50 Transmitting data number setting y Word data number is set that Master will transmit to inverter through communication v Inverter can receive 8 Word data from the Master for the maximum v You must set exactly same with the number of transmitting data of Master program 11 SV iS7 RNet Manual 11 Para Control 1 8 COM 51 58 Transmitting address 1 8 setting v Inverter address is set for data which Master gives to inverter v Itis possible to set inverter address for communicating from COM 51 to COM 58 but Master transmits to inverter data as the number of COM 50 Para Ctrl Num through communication 12 Lost Cmd Mode PRT 12 Operation method when losing communication command v Inverter operation method can be set for the case of communication command lost Commun
2. RNet manual 1 Fixed Screw M3 1 SV iS7 RNet Manual 5 RNet communication board Interior and appearance Installation 1 Interior Pin Connector Inverter Connector Swi Connector gt SW1 Pin 1 terminal resistance connecting setting switch On 120 8 Ohm terminal resistance connected Pin 2 4 Not used 2 Appearance Installation RNet terminal ote ray y C2 aa Inverter connection Wk WOW LED Display N SA y lt RNet communication board installed lt RNet communication board appearance gt in IS7 inverter gt LS Industrial Systems 6 6 RNet LED Information SV iS7 RNet Manual Four LEDs are installed in iS7 RNet communication board informing the user of present RNet status In iS7 RNet communication board LED is located in the below turn Green OOo Green Green CPU OO LED name Color Function CPU Green ON 0 5sec On 0 5sec OFF It shows that the power is fed to RNet communication board and CPU is operating normally TX RX Green Green TX Led is ON when inverter responds to the request of PLC RX Led is ON when inverter receives the request of PLC Error Red Be On with the same period of CPU Displayed when Option Trip occurs Option Trip is related with the CAN communication interruption between RNet card and inverter Be On with the oppos
3. board It can cause malfunction by static electricity Connection changing like communication wire change must be done with power off It can cause communication faulty or malfunction Be sure to connect exactly between Inverter and option board It can cause communication faulty or malfunction Check parameter unit when setting parameter It can cause communication faulty SV iS7 RNet Manual 1 Introduction RNet communication board makes the connection between PLC of LSIS and SV iS7 inverter by a fast series communication so that PLC sequence program can control the inverter by high speed communication operation of 1 Mbps Controlling and monitoring inverter by PLC sequence program makes it easier to install and modify the system A number of inverters can be connected by two communication lines so that saving installation time through simple wiring and easy replacement can be possible Using extra devices of PLC and connecting with various systems including PC the factory automation can be easier 2 Technical date for RNet communication board Item Specifications Transmission Speed 1Mbps Encoding type Manchester Bi phase L Frame synchronization type Transmission distance 1 per segment Transmission distance If repeater is used Maximum 750m Maximum 750m x 6 repeaters 1 5 25km Electric Transmission route Twisted pair shielded cable RNet dedicated cable Cable name LIRE
4. D 10310000963 LS Industrial Systems Shanghai Co Ltd gt gt China Address Room E G 12th Floor Huamin Empire Plaza No 726 West Yan an Road Shanghai China Tel 86 21 5237 9977 LS Industrial Systems Wuxi Co Ltd gt gt China Address 102 A National High amp New Tech Industrial Development Area Wuxi Jiangsu China e mail Xugh lgis com cn Tel 86 510 534 6666 Fax 86 510 522 4078 LS Industrial Systems Beijing Office gt gt China Address B tower 17th Floor Beijing Global Trade Center building No 36 BeiSanHuanDong Lu DongCheng District Beijing China el 86 10 5825 6025 LS Industrial Systems Guangzhou Office gt gt China Address Room 1403 14F New Poly Tower 2 Zhongshan Liu Rad Guangzhou China e mail zhangch lgis com cn el 86 20 8326 6754 Fax 86 20 8326 6287 LS Industrial Systems Chengdu Office gt gt China Address Room 2907 Zhong Yin B D No 35 Renminzhong 2 Road Chengdu China e mail hongkonk vip 163 com el 86 28 8612 9151 Fax 86 28 8612 9236 LS Industrial Systems Qingdao Office gt gt China Address 12th Floor Guodong building No52 Jindun Road Chengdu China e mail bellkuk hanmail net el 86 532 580 2539 Fax 86 532 583 3793 X LS Industrial Systems constantly endeavors to improve its product so that RNet Option Board Information in this manual is subject to change without notice SV iS7 Series 2008 8 LS Industrial systems Co Ltd 2008 Al
5. F NN Nj Address information COM 33 Para Status 3 Ox000A 0x0000 OxFFFF COM 50 Para Ctrl Num 2 0 8 Transmitting data number COM 51 Para Control 1 0x0005 0x0000 OxFFFF Transmitting inverter COM 52 Para Control 2 0x0006 0x0000 OxFFFF Address information 8 3 Communicating with PLC After finishing PLC RNet module setting refer to PLC RNet module manual if Inverter parameter setting is completed as above communication between PLC and RNet is possible 14 SV iS7 RNet Manual Warranty Product LSIS Communication Installation Name Option Card Date Model SV iS7 RNet Warranty Name Communication Card Period Name Customer Address Tel Name Sales Address Office Tel This product has been manufactured through the strict QC control and inspection of LS Industrial Systems Warranty period is 12 months after installation or 18 months after manufactured when the installation date is unidentified However the guarantee term may vary on the sales term n warranty service information gt If the defective part has been identified under normal and proper use within the guarantee term contact your local authorized LS distributor or LS Service center Out of warranty service information gt The guarantee will not apply in the following cases gt Troubles are attributable to a user s intentional negligence or carelessness Da
6. OM 36 Para Status 6 0x0000 0x0000 OxFFFF Receiving Address 6 COM 37 Para Status 7 0x0000 0x0000 OxFFFF Receiving Address 7 COM 38 Para Status 8 0x0000 0x0000 OxFFFF Receiving Address 8 Transmitting data COM 50 Para Ctrl Num 2 0 8 number setting COM 51 Para Control 1 0x0005 0x0000 OxFFFF Transmitting Address 1 COM 52 Para Control 2 0x0006 0x0000 OxFFFF Transmitting Address 2 COM 53 Para Control 3 0x0000 0x0000 OxFFFF Transmitting Address 3 COM 54 Para Control 4 0x0000 0x0000 OxFFFF Transmitting Address 4 COM 55 Para Control 5 0x0000 0x0000 OxFFFF Transmitting Address 5 COM 56 Para Control 6 0x0000 0x0000 OxFFFF Transmitting Address 6 COM 57 Para Control 7 0x0000 0x0000 OxFFFF Transmitting Address 7 COM 58 Para Control 8 0x0000 0x0000 OxFFFF Transmitting Address 8 None Operation method when PRT 12 Lost Cmd Mode None Free Run losing communication Dec command Decision time of Lost PRT 13 Lost Cmd Time 1 0 sec 0 1 120 0 sec communication command time SV iS7 RNet Manual 1 Option Type 1 CNF 30 Display the type of communication board v Option Type 1 displays the type of communication card built in inverter v If RNet communication board is installed properly and there is no error in RNet communication board RNet is displayed 2 Cmd Source DRV 06 Operation command Source setting v At Cmd Source parameter set the inverter operation command source If you command
7. User Manual RNet Option Board oV iS7 Series Use this board after read Safety Instruction of this manual carefully before using and follow the instructions exactly Please hand this user manual to end user and trouble shooting manager After read this manual keep it at handy for future reference LS Industrial Systems SV iS7 RNet Manual Before using the product thank you for using our SV iS7 RNet Option Board Safety Instruction To prevent injury and danger in advance for safe and correct use of the product be sure to follow the Safety Instructions The instructions are divided as WARNING and CAUTION which mean as follow WARNING This symbol indicates the possibility of death or serious injury BS CAUTION This symbol indicates the possibility of injury or damage to property The meaning of each symbol in this manual and on your equipment is as follows A N This is the safety alert symbol This is the dangerous voltage alert symbol After reading the manual keep it in the place that the user always can contact easily Before you proceed be sure to read and become familiar with the safety precautions at the beginning of this manual If you have any questions seek expert advice before you proceed Do not proceed if you are unsure of the safety precautions or any procedure SV iS7 RNet Manual N WARNING Be cautious about dealing with CMOS elements of option
8. V AMESB 16 PC 717 6705 Manufacturer LS Cable Network terminal resistance Terminal 120 80hm 1 2W with an error range of 5 Built in RNet communication board Maximum points per station Master Slave 64 points Master point 0 Slave points 1 63 Maximum protocol size 256 bytes Frame format Field Bus standard IEC TC65 SC65C WG6 65C 90 8 Access method to service zone Token Passing SV iS7 RNet Manual Item Specifications Connection Oriented Service Connectionless Service Frame error check CRC16 Communication type 1 Segment It means local network connecting all stations using the same Token without using any connecting devices Gateway EOC and repeater 3 RNet cable connection Communication aa Description terminal name TRX Communication signal terminal N TRX Communication signal terminal P SG Shield Signal Ground TRX Communication signal terminal N TRX Communication signal terminal P v Each two TRX TRX signals are connected in parallel v When installed at terminal if you turn on the 1 switch of RNet communication board terminal resistance of 120 80 1 2W is connected to communication signal terminal TRX and TRX v Frame Ground is connected with inverter body If inverter body is put to earth SHIELD line is to be connected to Frame Ground 4 Product Constituents RNet communication board 1
9. e picture below attach power module and CPU to Base and connect RNet Master module KGL RMEA to base Connect RNet Master module terminal TRX TRX to iS7 RNet communication card terminal TRX TRX using RNet dedicated cable for creating network RNet dedicated XGP ACF j XGK CPUS XGL RHEA Mi 153 gt AR lt XGT PLC RNet Module gt lt IS7 RNet Comm card gt CS industrial Systems 13 SV iS7 RNet Manual 8 2 Inverter Parameter setting Inverter parameter needed to set for RNet communication is as bellows Inverter FieldBus ID Transmitting data number for communicating with Master Inverter address information for transmitting Receiving data number for communicating with Master Inverter s address information for receiving First set inverter communication ID Set COM 07 FBus ID In the example inverter FieldBus ID is set as 1 And set transmitting and receiving data for communicating with RNet Here 2 Word transmitting and 3 Word receiving communication is done Set inverter Address for transmitting and Address for receiving gt Parameter setting value at the example Code Parameter name Value Range Description Field Bus ID COM 07 FBus ID 1 163 Do not set 0 0 is fixed for Master COM 30 ParaStatus Num 3 0 8 Receiving data number COM 31 Para Status 1 0x0007 0x0000 OxFFFF _ Receiving Inverter COM 32 Para Status 2 0x0008 0x0000 OxFFF
10. ication command lost is valid if DRV O6 Cmd Source is FieldBus or DRV 07 Freq Ref Src is set as FieldBus v If Lost Cmd Mode is set as None and communication command lost happens Trip Message doesn t occur if present operation state is kept v If Lost Cmd Mode is set as Free Run of Dec and communication command lost happens Free Run operation will be done or Dec operation with Lost Command message display can be done 13 Lost Cmd Time PRT 13 Communication command lost time v The standard time for communication command lost is set Communication command lost is valid if DRV 06 Cmd Source is FielBus or DRV 07 Freq Ref Src is set as FieldBus and then PRT 12 Lost Cmd Mode is Free Run or Dec Lost Lost Comm Line state I Cmd Cmd a PRT 13 Lost Cmd Time Lost Cmd Time Comm Cmd Lost recognition 12 SV iS7 RNet Manual 8 Connection to LSIS PLC with RNet The below describes in brief how to connect LSIS PLC XGT with iS7 RNet Communication option card Visit LSIS website and download XG5000 Program and install it If you install XG PD Program and XG5000 Program are installed in PC Transmitting and receiving is determined from the view of Master 8 1 H W Installation RNet Comm Card is installed in iS7 inverter When iS7 inverter turns ON check if RNet message can be displayed at CNF 30 Option Type 1 Install the PLC Hardware As th
11. ite period of CPU Network Configuration Error is displayed Network Configuration Error is related with setting as 0 the address point of inverter or when the setting of Control Num of inverter is different from the Master SV iS7 RNet Manual 7 RNet related Keypad Parameter Code Parameter name Initial value Setting range Description RNet display the type CNF 30 Option Type 1 of built in communication board Keypad Fx Rx 1 DRV 06 Cmd Source Fx Rx 1 ee eee Int 485 Source setting FieldBus PLC Keypad 1 Keypad 2 V1 11 DRV 07 Freq Ref Src Keypad 1 ue ean 12 Source setting Int 485 Encoder FieldBus PLC COM 06 FBus S W Ver Display the version COM 07 FBus ID 4 0 63 Hamminga Station address setting Fixing the COM 08 FBus BaudRate 1Mbps 1Mbps communication speed setting COM 09 FBus Led acute board LED Display COM 30 ParaStatus Num 3 0 8 Receiving data number COM 31 Para Status 1 Ox000A 0x0000 OxFFFF Receiving Address 1 COM 32 Para Status 2 Ox000E 0x0000 OxFFFF Receiving Address 2 SV iS7 RNet Manual Code Parameter name Initial value Setting range Description COM 33 Para Status 3 0x000F 0x0000 OxFFFF Receiving Address 3 COM 34 Para Status 4 0x0000 0x0000 OxFFFF Receiving Address 4 COM 35 Para Status 5 0x0000 0x0000 OxFFFF Receiving Address 5 C
12. l Rights Reserved
13. mage was caused by abnormal voltage and peripheral devices malfunction failure Damage was caused by natural disasters earthquake fire flooding lightning and etc gt When LS nameplate is not attached 15 Leader in Electrics amp Automation LS Industrial Systems E HEAD OFFICE Yonsei Jaedan Severance Bldg 84 11 5 ga Namdaemun ro Jung gu Seoul 100 753 Korea http eng sis biz Tel 82 2 2034 4643 4649 Fax 82 2 2034 4879 2034 4885 E LS Industrial Systems Tokyo Office gt gt Japan Address 16F Higashi Kan Akasaka Twin Towers 17 22 2 chome Akasaka Minato ku Tokyo 107 8470 Japan Tel 81 3 3582 9128 Fax 81 3 3582 2667 e mail jschuna Isis biz E LS Industrial Systems Dubai Rep Office gt gt UAE Address P O BOX 114216 API World Tower 303B Sheikh Zayed road Dubai UAE e mail hwyim Isis biz Tel 971 4 3328289 Fax 971 4 3329444 W LS VINA Industrial Systems Co Ltd gt gt Vietnam Address LSIS VINA Congty che tao may dien Viet Hung Dong Anh Hanoi Vietnam e mail srjo hn vnn vn el 84 4 882 0222 Fax 84 4 882 0220 E LS Industrial Systems Hanoi Office gt gt Vietnam Address Room C21 5th Floor Horison Hotel 40 Cat Linh Hanoi Vietnam Tel 84 4 736 6270 1 Fax 84 4 736 6269 W Dalian LS Industrial Systems co Ltd gt gt China Address No 15 Liaohexi 3 Road economic and technical development zone Dalian China e mail lixk lgis com cn Tel 86 411 8273 7777 Fax 86 411 8730 7560
14. operation by communication set FieldBus 3 Freq Ref Src DRV 07 Frequency command Source setting v At Freq Ref Src parameter set inverter frequency command source If you command frequency by communication set FieldBus 4 FBus S W Ver COM 06 Display the version of communication board built in inverter v Version of communication card installed at inverter is displayed 5 FBus ID COM 07 Setting inverter address y For communicating with Master set communication address allocated to inverter Y Setting from 1 to 63 is possible v You must not set the inverter address as 0 only RNet Master can have the 0 address If you set address as 0 the LED of RNet Communication card will display Network Configuration Error 6 FBus BaudRate COM 08 Communication speed display v The speed of RNet communication installed in inverter is fixed as 1Mbps So setting is impossible and only can display the speed information 10 SV iS7 RNet Manual 7 FBus Led COM 09 Communication card LED information display v The state of ON OFF of TX RX ERR CPU LED of RNet communication card is displayed at COM 09 through Keypad parameter v If you check COM 09 FBus LED through Keypad LED can be seen According to the LED order of COM 09 left gt right the information of TX RX ERR CPU LED is displayed in this order COM 09 Led state Example ai fal TX LED RX LED ERR LED CPU LED ON OFF ON OFF