Home
RX/N-400/410 LCD Keypad for Alarm System User Manual
Contents
1. FOR BETTER PROTECTION RX N 400 410 LCD Keypad for CAPTAIN vers Alarm System PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel 972 3 5587722 972 3 5500442 KA support pima alarms com gy http www pima alarms com LCD Keypads for CAPTAIN i Alarm System PIMA Electronic Systems Ltd does not represent that its Product may not be compromised and or circumvented or that the Product will prevent any death personal and or bodily injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The User understands that a properly installed and maintained equipment may only reduce the risk of events such as burglary robbery and fire without warning but it is not insurance or a guarantee that such will not occur or that there will be no death personal damage and or damage to property as a result PIMA Electronic Systems Ltd shall have no liability for any death personal and or bodily injury and or damage to property or other loss whether direct indirect incidental consequential or otherwise based on a claim that the Product failed to function Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For various reasons including but not limited to changes in environment conditions e
2. To identify the zone that is the cause of the alarm The letter is displayed above any Alarm Zone that was triggered while the system was last armed CHIME gt To enable the Chime mode Press and hold The message henii fH LEM is displayed for about 3 sec on the LCD display This mode activates a buzzer in the keypad when a Chime Zone is triggered This feature can be used to monitor unauthorized entry or exit in the defined zone when the system is not armed To learn how to program a Chime Zone see To program cancel a Chime Zone on page 15 CHIME gt To disable the Chime mode Press and hold The message henii F L Li is displayed for about 3 sec on the LCD display gt Toview system events in memory ES Master Code MEMORY SERVICE NEXT 2 and then scroll using the or _NEXT J keys KS to exit OR to view events scrolled automatically E Press and hold MEMORY gt To temporarily cancel the Entry Delay Time Press and hold PROGRAM and receive the following message DELAY ON Press and hold again DELAY OFF 10 LCD Keypads for CAPTAIN i Alarm System NOTE When this feature is enabled it is effective only until the system is disarmed gt Reporting PANIC Event to CMS Private Dialer Press and hold CHIME RESET and simultaneously for two seconds You can customize your system s response to a panic event for example calling the Monitoring Station or your
3. With the telephone number s to keep rp _ENTR J and with the RESET one s to delete lL cS to exit To delete all the telephone numbers amp Master Code cS RESET cs 4 x3 a gt 0 gt To set the time and date for the system amp Master Code S CLOCK KS current time HH MM 24 hours format ps ENTR KS current date YY MM DD format KS KS ED tis important to set the correct time and date to ensure proper functioning of your CAPTAIN Alarm System If NO time is entered the red Fault LED will blink LCD Keypads for CAPTAIN i Alarm System gt To program cancel a Chime Zone amp Master Code KS CHIME ET KS zone number po END This mode activates a buzzer in the keypad when a Chime Zone is triggered Chime Zones are indicated by the letter 1 in the display above the programmed zone number pas LCD Keypads for CAPTAIN i Alarm System FAULTS INDICATIONS LCD Keypad Display Description Low battery power No dial tone detected AC power failure Appears after initial power input or after total power reset AC and battery Very low DC supply to the alarm card PCB 1 Detector was shorten or cutoff A problem with the system software Detectors power line was shorten Failure to communicate with Central Monitoring Station CMS 4 GSM unit is not identified by system Low GSM signal SIM card failure GSM communication to CMS failure 4 A
4. by the installer to partition 2 toggle mode a LCD Keypad5 for CAPTAIN i Alarm System User can arm disarm only partitions allocated to him by the installer partitions 1 2 or both All keypads connected to the system share the same display even if they are allocated to different partitions IMPORTANT If the installer enabled the Failure Inhibits Arming feature the user will not be able to arm the system in case of failure i e AC Battery etc For further information on this feature turn to CAPTAIN I Ver 5 Installation Manual BY PASS gt To bypass reactivate alarm zone amp Master Code ES zone number EnD OR BY PASS KS Hold and press until you receive the following screen IS Enter User Code and receive the following screen I Enter zone number to be bypassed and receive the following conformation screen EREN zwa Time Bypassed zone in this example example zone 3 7234567691011 1215141516 Repeat process in order to bypass different zone s To cancel the bypass and reactivate the zone repeat the bypass activation process with this zone s number toggle operation IMPORTANT Every bypassed zone is logged in the system s memory including the time and date loan When Bypass mode is executed it is effective until you disarm the system LCD Keypads for CAPTAIN i Alarm System RESET gt To reset the smoke or fire detector Press and hold gt
5. private telephone number Consult your installer about programming a Panic Response In addition if the installer programmed User Code 8 as Panic Code entering user code 8 will Report a panic event to CMS logged in memory as Panic with time and date Disarm the panel or a single partition or both partitions gt Reporting DURESS Event to CMS Private Dialer Press and hold HOME 1 PHONE and simultaneously until a conformation beep from keypad NOTE The event is logged in memory as Duress and includes time and date 7 Reporting FIRE Event to CMS Press and hold and CODE simultaneously until a conformation beep from keypad NOTE The event is logged in memory as Fire and includes time and date gt To disable a keypad s audible tones Press and hold and simultaneously LCD Keypads for CAPTAIN i Alarm System 1 When the keypad s Audible Tone feature is disabled all audible tones and indications with that keypad are silenced gt To enable a keypad s audible tones Press and hold and ENTR l simultaneously until you hear a beep Green LED and System Status The Green ARMED LED will indicate the system status as follows Blinking The system is in Entry before disarming or Exit after arming Delay Time mode Steady Light The system is armed Incase of partitions see the table below Armed Partition s LCD Screen Display Green LED Partition 1 armed m
6. anni UN KR LI 1 blink every 4 seconds Partition 2 armed Marion Li 2 blinks every 4 seconds Both partitions armed AJ DH ERRE Stays lit constantly entire system IMPORTANT Before beginning to program the CAPTAIN i Alarm System you must first enter the Master Code the default factory code is 5555 When Em i eE appears on the LCD display you may proceed with programming your system gt To cancel a command X3 KS Start the programming procedure from the beginning LCD Keypads for CAPTAIN i Alarm System CODE gt To program a Master Code Initial Master Code 3 E ES new Master Code 4 6 digits I3 _ENTR J co CEN x eno gt To program User Code 1 ES New Master Code 1 SERVICE CODE cS KS _ENTR J KS new User Code 4 6 digits co E a gt END gt ete gt To delete User Code 1 E Master Code K amp S SERVICE RESET DET acs ENTRY a TE ac e as sw gt To program User Codes 2 to 8 KS Master Code S SERVICE CODE Ko CODE as many times as the User Code number cs S ES new User Code 4 6 digits IS ENTR J Ko Ewo gt ED CODE gt To delete User Code 2 to 8 K3 Master Code KS SERVICE cs as many as the User Code number cS _ENTR J RESET c ED l ae ae LCD Keypads for CAPTAIN i Alarm System Y When programming or deleting User Code 6 enter the Master Code press the key followed by pre
7. lectric or electronic disruptions and tampering the Product may not perform as expected The user is advised to take all necessary precautions for his her safety and the protection of his her property This document may not be duplicated circulated altered modified translated reduced to any form or otherwise changed unless PIMA s prior written consent is granted All efforts have been made to ensure that the content of this manual is accurate Pima retains the right to modify this manual or any part thereof from time to time without serving any prior notice of such modification Please read this manual in its entirety before attempting to program or operate your system Should you misunderstand any part of this manual please contact the supplier or installer of this system Copyright 2005 by PIMA Electronic Systems Ltd All rights reserved You can contact us at PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel http www pima alarms com LCD Keypads for CAPTAIN i Alarm System SAFETY INSTRUCTIONS Your CAPTAIN i alarm system has been registered in accordance with EN60950 and its rules EN 60950 requires us to advise you the following information 1 In this alarm system exists hazards of fire and electric shock To reduce the risk of fire or electric shock do not expose this alarm system to rain or moisture Pay attention Telephone cords could be a good conductor for lightings energy Do not
8. open the door of the alarm system Dangerous high voltages are present inside of the enclosure Refer servicing to qualified personnel only This alarm system should be used with AC 230V50Hz protected by anti electric shock breaker To prevent electric shocks and fire hazards do NOT use any other power source Do not spill liquid of any kind onto the unit If liquid is accidentally spilled onto the unit immediately consult a qualified service Install this product in a protected location where no one can trip over any line or power cord Protect cords from damage or abrasion Disconnect all sources of power supply before proceeding with the installation Pay attention do not install low voltage wires near by AC power wires they should be separated Connect the AC transformer output to the terminal block on the control panel as marked Connect the AC line cord to line power terminals as marked GND N L LCD Keypads for CAPTAIN i Alarm System INTRODUCTION Congratulations on your purchase of the CAPTAIN i Alarm System Much care has been taken in developing the CAPTAIN i alarm system which will provide you with unprecedented peace of mind The CAPTAIN i user friendly operation and advanced features will professionally protect your home or business It is important to familiarize yourself with the CAPTAIN i Alarm System in order to take full advantage of the complete range of the CAPTAIN i features To a
9. problem with keypad connection to the panel Contact the installer Check the phone line at the premises Set the system time and date Contact the Central Monitoring Station gt Check with cellular carrier J deu i gt gt pk i gt O AJ D lt G An Jo ko I N Oo UI Non
10. splays information about the zones status Each of the following characters signifies a certain status The characters appear above the zone number on the display Closed zone Opened zone Bypassed zone Hi Alarm zone zone triggering alarm i Chime zone Failed zone disconnected or shorten Tamper event in a wireless detector LCD Keypads for CAPTAIN i Alarm System System Functions IMPORTANT The K9 symbol indicates information that you must enter gt To arm the entire alarm system amp Any User Code User Code 1 to 8 that was allocated by the installer to both partitions ON OFF OR Master Code aj OR Short code To disarm the entire alarm system amp Any User Code User Code 1 to 8 that was allocated by the installer to both partitions ON OFF OR Master Code SY IMPORTANT Entering the Master Code when one of the partitions is armed will arm the other partition as well Entering the Master Code when both partitions are armed will disarm the entire system HOME 1 gt Toarm the alarm system in HOME Press and hold or GD ct Any User Code OR ES Short code To disarm the alarm system in HOME amp Any User Code User Code 1 to 8 that was allocated by the installer to that partition gt To arm disarm Partition 1 Any User Code that was allocated by the installer to partition 1 toggle mode gt To arm disarm Partition 2 1 Any User Code that was allocated
11. ssing the key six times CODE gt To program a Short Code Master Code amp K5 Back KS ES new Short Code 2 digits KS m cx END CODE gt To delete a Short Code Master Code KS s KS Back gt ED A e PROGRAM gt To program Automatic Arming Master Code cS HH MM 24 hours format KS ET PHONE gt To program telephone number s amp Master Code SY ES Enter the first telephone number including area code K ENTR ES Enter the second telephone number including area code KS ES Enter the third telephone number including area code KI ENTR s TEND LCD Keypads for CAPTAIN i Alarm System You can program up to three telephone numbers into the system memory which will be called in an emergency or when in Alarm Event To skip a number i e leave the programmed number or leave it ENTR empty simply press Press Emo to exit the mode If the CAPTAIN Alarm System is connected behind a PBX you must enter the outside line prefix digit and an asterisk before the telephone number For example 9 555 5555 When the CAPTAIN Alarm System calls to one of the programmed telephone numbers a siren tone is heard on the subscriber telephone For playing a pre recorded message a VU 20 unit optional is required Consult your installer for this option It is also possible to connect the microphone unit MIC 200 PHONE gt To delete telephone number s amp Master Code S
12. ssure optimum safety and security you should test the CAPTAIN i Alarm System once a week Main Features of CAPTAIN i 6 programmable zones Two partitions Dialer Up to three preset private telephone numbers and four Monitoring Station numbers Various modes of arming and disarming keypad key remote control automatic Four types of keypads A simple LED keypad RXN 406 a seven segment and LED display keypad RX 180 LCD keypads RX N 400 or RX N 410 and Anti vandal keypad RX 200 Up to six different keypads connected in parallel Two operating modes Full or Home System Events is registered in memory so gt oo Various operating codes Master Code up to eight User Codes and Short Code User Code 8 can function as DURESS code Optional temporary bypass of zones Chime mode per zone operates the keypad buzzer when a zone is opened e g to monitor a back door when system is disarmed Monitoring Station Communicator built in dialer integrated Long Range Radio and Cellular Transmitters LCD Keypads for CAPTAIN i Alarm System Inhibit system from arming in case of failure optional Short keys for DURESS and FIRE codes Access and Operation Codes The following codes are used to access and operate the CAPTAIN i Alarm System Master Code Use this code when programming system parameters The default factory Master Code is 5555 For security reasons it is not recommended to use the defa
13. ult code to arm or disarm the system User Code 4 6 digit code Up to eight User Codes can be programmed User Code 1 to User Code 8 Short Code A convenient two digit code used only to arm the system Duress Code 4 6 digit code used for disarming the system in case it is armed and sending duress event to MS or sends silent duress event to MS in case system is disarmed PIMA s LCD keypads RXN 400 and RXN 410 were especially designed for maximum simplicity durability and decorative design The keypad is used for arming disarming and programming the system as well as displaying time and date system status information events and defaults memory log and more Up to six keypads can be connected to the system CAPTAIN i Both keypad models are identical except for the size of the display screen HIE HF mt tt J m Ge ae RXN 400 BO Normal screen 15 x 60 mm Large screen 23 x 97 mm LCD Keypads for CAPTAIN i Alarm System Keypad Description System Fault System Status Description see page 14 System Time RXN 410 Zones Status ARM LED Num amp Function green keys Fault LED Navigation amp red Programming keys Display Screen The upper line displays the System Fault System Status and Time System Status System communicating or testing PSTN line System reporting to Monitoring Station via radio transmitter The lower line di
Download Pdf Manuals