LP30 USER MANUAL

image

Contents

1. REFERENCES INFLAMMABLE OBJECTS NON INFLAMMABLE OBJECTS A 200 mm 100 mm B 1 500 mm 750 mm 200 100 Minimum 80 cm S floor protection y Fue toe B le __ Air inlets Inspection Xy Chimney windproof m om e A 3 5 a Inspection Flue N Inspection N NY Extraflame ENGLISH lt 3m e External pipe that is isolated dl N a Inspection 45 e N Inspection Appliance connection to the flue and combustion products evacuation The flue must receive the discharge from only one heat generator Direct discharge towards closed spaces is forbidden even with clear sky The direct discharge of the combustion products must be at roof and the smoke pipe must have the features provided in the Chimney or individual flue section CHIMNEY CAP The chimney cap must comply with the following requisites have an internal section equivalent to that of the chimney have useful outlet section not lower than double the chimney internal section be built in order to avoid rain snow foreign bodies penetrating the chimney and so that in the event of winds in any directi
2. SET TEMPERATURE gt SET H20 2 Y D SET POWER Y gt SET ADJUSTMENTS gt ENABLE CHRONO Y Q Y gt STATUS Pi STOVE STATUS PELLETS gt USER MENU gt SET CLOCK gt SET CHRONO LANGUAGE DISPLAY TECHNIC SET RESERVED TO THE QUALIFIED A RESET TECHNICIAN BASIC INSTRUCTIONS Before lighting the stove the following points must be The following recommendations must be followed the first verified times the stove is ignited o The hydraulic system must be completed in compliance Itis possible that slight odours are produced due to the with the guidelines of the regulations and the manual drying of the paints and silicones used Do not remain inthe The tank must be full of pellets environment for long periods o The combustion chamber must be clean Donottouch the surfaces as they could still be The burn pot must be completely free and clean unstable hermetic closure of the fire door and the ash _ Air the room well several times drawer o The hardening of the surfaces is terminated after several Check that the power supply cable is connected correctly heating processes The bipolar switch in the rear right part must be positioned o This appliance must not be used to burn waste 1 DO NOT ALLOW THE BAG OF PELLETS COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE FILLING PHASE IN THE EVENT OF CONTINUOUS NO IGNITION CONTACT AN AUTHORISED TECHNICIA
3. 80 C PUMP OPERATION The pump activates water circulation when the t of the water inside the stove reaches 60 C As the pump always functions above 60 an always open heating area is recommended to make product functioning homogenous preventing overheating blocks Normally this area is defined Safety zone BURN POT CLEANING At pre set intervals the stove performs burn pot cleaning switching the machine off When the cleaning phase is finished the stove will re start automatically and continue its work going back to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to modulate automatically bringing itself to the minimum power If the temperature increases beyond the set point it will automatically switch off indicating H OFF and will automatically go back on when the temperature drops below the set point SWITCH OFF Press key 1 for three seconds When the operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The flue gas exhaust motor will remain on until the stove temperature has dropped below the factory parameters RE IGNITION The stove can only be re ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied IGNITION FIRST IGNITION COULD EVEN FAIL AS THE AUGER IS EMPTY AND IS NOT ALWAYS ABLE TO LOAD THE BURN POT WITH THE RE
4. EVACUATION SYSTEM inci sms 15 SMOKE CHANNEL OR FI TINGS emilir senar an din da rl aracimda Gia CHIMNEY OR INDIVIDUAL FLUE CHIMNEY sii as CONNECTION TO EXTERNAL AIR INEETS 22 o INSULATION FINISHINGS COVERING AND SAFETY RECOMMENDATIONS PELLETS AND FEEDING DISPLAY ICONS KEY GENERAL A A NN a A A cr A BASIC INSTRUCTIONS COMMISSIONING SETTINGS DS 1 HIMEADATAMGNT HEANISIY EAR VA AUS TING A MAA MM R lt E o OPERATION AND LOGIC ADDITIONAL THERMOSTAT ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE DITION AIGIERMOSTAT INSTAPLATION ESE AAA AAA KAD Extraflame QEXtraflame ENGLISH TECHNICAL FEATURES FEATURES 30 Weight kg 333 Height mm 1406 Width mm 875 Depth mm 772 Flue exhaust pipe diameter mm 120 Air intake pipe diameter mm 60 Max global heat output kW 338 useful thermal power to the water kW 31 1 Minimum global heat output kw 10 Min useful heat output kw 8 6 Max hourly fuel consumption kg h 7 0 Min hourly fuel consumption kg h 2 0 Tank volume l 121 Recommended flue draught mbar 0 1 Nominal electric output W 470 Nominal voltage Vac 230 Nominal freguency Hz 50 Water inlet outlet pip
5. Head m The diagram at the side illustrates the behaviour of the pump used on our thermo products at the speeds that can be set 0 0 0 0 5 1 0 1 5 2 0 2 5 Flow rate m h OExtraflame SAFETY DEVICES SAFETY DEVICES STOVES KEY PRESENT NOT PRESENT Circuit board intervenes directly by sending the product into alarm conditions until complete cooling in the case A of breakage of flue gas motor pellet feed motor breakage black out if more than 10 seconds no ignition Door micro switch With the door open burn pot system operation is blocked Electronic pressure switch in the event of inadeguate P depression it takes the machine to alarm conditions F 2 5 A 250 V fuse stoves protects the machine from violent current drops 85 C calibrated mechanical bulb with manual rearm intervenes by blocking fuel feed whenever the pellet tank t reaches the limit of 85 C Rearm must be performed by gualified staff and or the manufacturer s technical after sales assistance Pellet feed box temperature control probe if the tank over heats the machine automatically modulates to return to normal temperature values in the models envisioned Mechanical air pressure switch blocks the pellet in the 5 event of insufficient depression in the models envisioned INSTALLATION The installation must be in compliance with UNI 10683 2005 heat generators fed with wood an
6. It indicates weekly programming operation 2 _ Hand indicator weekly programming disabled d Chrono indicator weekly programming active Indicates the contact of the external additional thermostat It indicates pump operation EN Closed contact the contact of the external additional thermostat Off pump deactivated STBY is closed On pump active Sg Flashing the safety device is active 20 temperature gt 85 C STBY Open contact the contact of the external additional thermostat is open Extraflame has an optional additional board that allows the boiler the following further functions when managing the system The table below indicates the various possibilities that the optional can offer DHW Storage Management id Puffer Management 3 heating areas Instant DHW option Puffer pump 4th heating area management Anti legionella management for DHW storage DHW storage management Auxiliary output management and control QExtraflame ENGLISH GENERAL MENU s Extraflame 1 ON OFF MENU EXIT n 2910912012 0 PRESS ACCESS THE MENU TURN TO SELECT ACCESS MODIFY PRESS MEMORISE 3 GO BACK THE PREVIOUS MENU
7. STAND BY Stove off waiting for re ignition due to an external thermostat The stove will only re start when the external thermostat makes a request COOLING A new ignition 15 attempted when the stove has just been switched off When the stove switches off one must wait for the complete shutdown of the fumes motor then clean the burn pot The stove can only be STAND BY re ignited when these operations have been performed HOFF Stove off due to water temperature over set As soon as the water temperature drops below the pre set parameters the stove will switch back on BLACKOUT The stove is cooling after a power cut STAND BY Once cooling is completed it will re start automatically ANTI FREEZE The anti freeze function is in progress as the H20 t is below the factory set threshold the pump is active until the water reaches the pre set factory parameter 2 C ANTILOCK AUTO BLOW The pump antilock function is in progress only if the stove has been in an OFF state for at least 96 hours the pump is activated for the time pre set by the manufacturer in order to prevent it from blocking The automatic blow is active EXCHANGER BLOCK Automatic exchanger cleaning is blocked Extraflame ENGLISH ALARMS When the boiler goes into alarm mode the screen becomes red and does not accept commands outside the display When the screen turns green ALARMS MEMORY will be displayed with the type of alarm and the bo
8. certifies its eligibility filled in in all its parts A INSTALLATION REPORT filled in by the installer B INSPECTION REPORT AND VALIDATION OF THE WARRANTY Filled out by the client dealer and a qualified technical assistance centre 5 The warranty document filled in and accompanied by the purchase fiscal document issued by the dealer must be kept and shown to the authorised technician in the event of intervention THE WARRANTY IS NOT CONSIDERED VALID IN THE FOLLOWING CASES 1 The warranty conditions described above have not been respected 2 Installation has not been performed with respect to the Standards in force regarding the provisions described in the manual book provided with the appliance 3 Negligence of the customer due to lack of or incorrect maintenance of the product 4 Presence of electric and or hydraulic plants that do not comply with the standards in force 5 Damages deriving from atmospheric chemical electro chemical agents improper use of the product modifications and tampering with the product inefficacy and or unsuitability of the flue and or other causes not deriving from the manufacture of the product 6 Combustion of materials not compliant with the types and quantities indicated in the manual book supplied 7 damages caused by transport It is therefore recommended to carefully check the goods on receipt immediately informing the dealer of any damage making a note on the transport document and on
9. or not on off TUESDAY PRG1 gt Day allowed or not on off WEDNESDAY PRG1 gt Day allowed or not on off THURSDAY PRG1 Day allowed or not on off _ FRIDAY PRG1 gt Day allowed or not on off SATURDAY PRG1 gt Day allowed or not on off SUNDAY gt Day allowed or not on off _ SETPRGI gt Setting water t ADJUSTING LANGUAGE see chapter commissioning settings DISPLAY Activating OFF the back light of the display will go off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine CONTROLS PROCEDURE DISPLAY Turn P2 to select the icon Press P2 to confirm Turn 2 to select DISPLAY Confirm pressing P2 Turn 2 to select ON OFF i Press P2 to confirm and exit If you wish to exit without memorising press key P1 RESET DISPLAY OFF 9 9 e Allows to reset all values modifiable by the user to the default values CONTROLS PROCEDURE Turn P2 to select the icon Press 2 to confirm Turn 2 to select RESET Confirm pressing P2 Turn 2 to select ON Press P2 to confirm The display will show DONE to confirm the command 9 9 9 9 Extraflame ENGLISH CLEANING UNDER USER S RESPONSIBILITY Some images could be offset from the original model DAILY Burn pot The burn pot is cleaned via a mechanical system at pre fi xed intervals a
10. the carrier s copy EXTRAFLAME S p A is not liable for any damage that can directly or indirectly affect persons objects and pets as a consequence Extraflame ENGLISH of failure to comply with the prescriptions indicated in this manual book ALL PARTICULARS SUBJECT TO NORMAL WEAR ARE NOT COVERED BY WARRANTY This category includes The gaskets all ceramic or toughened glass coverings and cast iron or Ironker grids the painted chrome or gold plated details the majolica the handles and the electric cables o Colour variations crackles and slight size differences f the majolica parts are not a reason for claims as they are natural features of the materials themselves Parts in refractory material Masonry work system particulars for the production of domestic hot water not supplied by EXTRAFLAME S p A water products only heat exchanger is excluded from the warranty unless an adequate anti condensate circuit is realised which guarantees minimum return temperature of the appliance of at least 55 C only water products FURTHER CLAUSES The warranty also excludes any calibration or regulation interventions of the product in relation to the type of fuel or the type of installation The warranty is not extended if particulars are replaced No compensation will be paid for the time the product is inefficient This warranty is valid only for the purchaser and cannot be transferred WA
11. F conditions using key 1 and repeat BLACK OUT 9 9 the procedure described in the Ignition chapter NO PELLETS 7 Check for the presence of pellets in the feed box The motor reducer does not feed pellets Adjust the pellet flow see Pellet feed adjustment The door is not closed correctly Check hermetic door closure DEPR ALARM The ash drawer is not closed correctly Check hermetic closure of the ash drawer The combustion chamber is dirty Check cleanliness of the fumes pipe and the combustion The flue exhaust pipe is blocked chamber DEBIMETER Flow sensor faulty Ge centre FAULT Sensor disconnected The water in the stove has exceeded 95 C Possible air in the system H20 OVERTEMP Lack of adeguate circulation Contact after sales centre Lack of or inadeguate safety zone Possible circulator anomaly TRAPDOOR FAULTY The A tomatie cl aningotthe burnipot Contact after sales centre is blocked The system pressure read by the pressure MINIMUM switch is too low Possible presence of air in the system Contact after sales centre PRESSURE ALARM Possible lack of water or leaks due to anomalies in some system component H20 PROBE H20 probe failure Contact after sales centre ALARM MAX 2 The pressure of the water has exceeded ll vessels are not damaged or PRESSURE ALARM the max threshold Check that the cold system is loaded at the correct pressure Extraflame ENGLISH WARRANTY CONDITIONS EXTRAFLAME S p A
12. If the stove has functioning problems owing to the guantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories NO FUEL the stove can never develop a suitable flame tending to remain very low even at high powers at minimum power the stove tends to almost switch off taking the stove into NO PELLETS alarm condition when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL the stove develops a very high flame even at low power the panoramic glass is very dirty obscuring it almost totally the burn pot tends to become encrusted blocking the holes for air intake due to the excessive pellet feed as it is only burned partially The adjustment to be performed is in percentage Therefore a modification of this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 30 to 20 CONTROLS PROCEDURE PELLET ADJUSTMENT From the main screen turn P2 to select the SET ADJUSTMENTS icon Sen Press P2 to confirm and successively press P2 again to select PELLET 2 00 REGULATION Turn P2 to modify the parameter as a percentage 30 20 7 Confirm memorising by pressing 2 to exit without memorising press key P1 AH user MENU SET CLOCK chapter commissioning settings CHRONO The chrono all
13. N R DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION Extraflame ENGLISH COMMISSIONING SETTINGS Once the power cable at the back of the stove has been connected move the switch also located on the back to 1 The switch at the back of the stove powers the stove board The stove remains off and a first screen appears on the panel reading OFF ADJUSTING TIME DAY MONTH AND YEAR Set clock allows to adjust the time and date CONTROLS PROCEDURE From the main screen turn P2 to select the icon SET CLOCK Press P2 to confirm SATURDAY Turn P2 to select SET CLOCK Confirm pressing P2 Turn P2 to select the desired parameter Press P2 to enter modification mode Turn P2 to modify the value Press P2 to confirm and exit If you wish to exit without memorising press key P1 0 9 9 9 9 ADJUSTING LANGUAGE The boiler allows to set the following languages Italian English French German and Spanish ITALIAN is the default setting CONTROLS PROCEDURE Turn P2 to select the icon LANGUAGE Press P2 to confirm Turn P2 to select LANGUAGE Confirm pressing P2 Turn P2 to select the desired parameter Press P2 to enter modification mode Turn P2 to modify the value Press P2 to confirm and exit If you wish to exit without memorising press key P1 9 9 0 BURN 212 IT 15 PROHIBITED TO USE THE APPLIANCE WITHOUT THE BURN POT CONE SEE FIGURE TO THE SIDE IN
14. NDITIONS OF INSTALLATION RECOMMENDED DISTANCES FOR THE BOILER COMPARTMENT Below are a few images relative to the minimum distances required in the boiler room The company recommends the following measurements to be complied with REFERENCES NON INFLAMMABLE OBJECTS REFERENCES NON INFLAMMABLE OBJECTS A 500 mm D 300 mm B 1 000 mm E gt 80 cm 1 000mm Extraflame ENGLISH WARNINGS The instruction manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost reguest another copy from the area technician This product must be intended for the use it has been specifically made for The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed It is necessary to bear in mind all laws and national regional provincial and town council Standards present in the country the appliance has been installed Extraflame S p A cannot be held responsible for the failure to comply with such precautions After remo
15. PLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY QUALIFIED PERSON SO AS TO AVOID AL RISKS i gt FOR CORRECT FUNCTIONING THE STOVE MUST UNDERGO ROUTINE MAINTENANCE BY A QUALIFIED TECHNICIAN AT LEAST ONCE A YEAR MAKE SURE THAT THE ASH IS COMPLETELY COLD BEFORE EMPTYING IT INTO A SUITABLE CONTAINER THE CHIMNEY SWEEP BIN IS AN ACCESSORY AVAILABLE FROM THE COMPANY Fumes motor disassembly and cleaning and fumes pipe and T new silicone in the provided points Y Inspections of gaskets ash drawer and door replace them and apply silicone where envisioned v Combustion chamber and heat exchanger full cleaning including ignition plug pipe v Feed box complete emptying and cleaning v Check air intake pipe and cleaning of the flow sensor Y Extraflame ENGLISH DISPLAYS DISPLAY REASON OFF Stove off START The start up phase is in progress PELLET FEEDING Continuous pellet feeding is in progress during the ignition phase IGNITION The ignition phase is in progress START UP The start up phase is in progress WORK The normal work phase is in progress MODULATION The stove is working at minimum CO Automatic burn pot cleaning is in progress CLEANING FINAL CLEANING The final cleaning 15 in progress
16. QUIRED AMOUNT OF PELLETS ON TIME TO REGULARLY START THE FLAME ori WAIT FOR THE MACHINE TO COOL DOWN GREEN SCREEN PRESS KEY 1 FOR3 SECONDS IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS WORKING CHECK THAT ROUTINE CLEANING STATED IN THE STOVE BOOKLET HAS BEEN CARRIED OUT CORRECTLY Extraflame ENGLISH ADDITIONAL THERMOSTAT There is a possibility to thermostat a room adjacent to the room where the stove is positioned just connect a thermostat following the procedure described in the next step it is recommended to position the optional mechanical thermostat at a height of 1 50 m from the floor The default STBY function is always active it cannot be disabled and the STBY clamp is jumpered contact closed ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE When the contact or external thermostat is not satisfied open contact temperature reached the stove will switch off As soon as the contact or external thermostat switches to the not satisfied status closed contact temperature to be reached it will re ignite after the boiler has cooled down N B stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions If stove is in OFF water temperature reached any additional contact or thermostat request will be ignored ADDITIONAL THERMOSTAT INSTALLATION Switch the appliance off using the master switch positioned on the rear of the stove Remove
17. RM Pressure indicator Intervenes by blocking fuel feed whenever the pellet tank t reaches the limit of 85 C Rearm must be performed by qualified staff and or the manufacturer s technical after sales assistance Acoustic alarm 100 C CALIBRATED MECHANICAL BULB WITH MANUAL REARM Regulation automatic circuit breaker switch managed Intervenes by blocking the fuel feed whenever the t of the water by board program inside the product is near to 100 Rearm must be performed by qualified staff and or the manufacturer s technical after sales Minimum and maximum pressure pressure switch assistance MINIMUM AND MAXIMUM PRESSURE SWITCH Water overheating automatic circuit breaker switch block Intervenes in the event of inadequate water pressure Rearm must thermostat be performed by qualified staff and or the manufacturer s technical after sales assistance Circulation system pump MECHANICAL AIR PRESSURE SWITCH Expansion system Blocks the pellet in the event of insufficient depression Pan SENNO During installation of the stove it is MANDATORY to adjust the system with a manometer in order to display the water pressure INSTALLATION AND SAFETY DEVICES The installation relative system connections commissioning and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these
18. RRANTY INTERVENTIONS The request for intervention must be sent to the dealer or after sales assistance Centre The warranty intervention envisions the repair of the appliance without any charge as provided by the law in force LIABILITY EXTRAFLAME S p A does not grant any compensation for direct or indirect damage caused or depending on the product LAW COURT The Vicenza Law Court is elected as the competent court for any disputes Extraflame Extraflame uExtraflame Riscaldamento a Pellet EXTRAFLAME S p A Via Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY FN 39 0445 865911 E 39 0445 865912 info extraflame it www lanordica extraflame com Extraflame reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties This document is available at www extraflame it support 004205236 Manuale Utente LP30 5512 002
19. RTHER INFORMATION RELATIVE TO THE HYDRAULIC CONNECTIONS AIR INTAKE FLUE EXHAUST AND DIMENSION SPECIFICATIONS OF THE PRODUCT IN QUESTION Extraflame ENGLISH INSTANT DOMESTIC HOT WATER PRODUCTION KIT WARNINGS if the instant hot water production kit is to be used contact the company technical after sales service STOVE POSITIONING For correct product functioning it is recommended to position it in a way that it is perfectly level with the aid of a spirit level REARM The figures below show the rearm positions of the tank 85 C and 20 100 C It is recommended to contact the qualified technician if one of the rearms should be triggered so as to verify the cause THERMO PRODUCTS FEATURES LP30 Water content of the thermo product heat exchanger 1 66 Volume of expansion vessel integrated into thermo product 1 12 Maximum content of water in the system for integrated expansion vessel I 170 3 bar safety valve integrated into the thermo product MES Minimum and maximum pressure switch integrated into the thermo product YES Pump integrated into the thermo product YES Pump max head m 5 Content of water in the system in addition to that ofthe 4 thermo product that can be managed with the integrated expansion vessel An additional expansion vessel must be installed for a higher content of water
20. THE CASE OF WEAR OR DETERIORATION REQUEST gt AFTER SALES ASSISTANCE FOR REPLACEMENT OF THE PART REPLACEMENT THAT IS NOT UNDER GUARANTEE AS THE COMPONENT IS SUBJECT TO WEAR CLEAN CHECK UP 1 2 gt BURN POT BOTTOM SHOULD THE CLEAN CHECK UP ALARM BE TRIGGERED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE OF RESIDUES OR SCALES THE HOLES AT THE BOTTOM MUST BE COMPLETELY FREE TO GUARANTEE CORRECT om COMBUSTION SEE CHAPTER CLEANING CARRIED OUT BY THE USER ONE CAN USE THE FUNCTION PELLET FEED ADJUSTMENT TO ADJUST COMBUSTION ACCORDING TO THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES ASSISTANCE CENTRE QExtraflame ENGLISH OPERATION AND LOGIC IGNITION Once the points listed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are available for the ignition phase After ignition and having reached the control temperature the stove interrupts the ignition phase and passes to STARTING STARTING During the start up phase the stove stabilises combustion increasing it progressively to then start ventilation and pass on to WORK WORK During the work phase the stove reaches the set power see following item ADJUSTING POWER SETTING Set the operating power from 1 to 5 Power 1 minimum level Power 5 maximum level 20 TEMPERATURE SET ADJUSTMENT Set the boiler temperature from 65
21. appliances is not allowed The mounting of the smoke channels must be carried out in order to guarantee smoke seal for the appliance functioning conditions limit the forming of condensate and avoid it being transported towards the appliance The mounting of horizontal routes must be avoided For appliances where ceiling or wall non coaxial discharges with respect to the appliance combustion product outlet have to be reached the direction changes will have to realised using open bends not greater than 45 see figures below For the heat generator appliances equipped with electric fan for expelling combustion products the instructions below must be followed Insulating product 457 lt 45 Flue pipe Inspection N 7 The horizontal routes will have to have a minimum upward slope of 3 The length of the horizontal route must be minimal and however not longer than 3 metres The number of direction changes including the one for effect of using the element must not be more than 4 In any case the smoke channels must seal the combustion and condensate products and be insulated if they pass outside the installation room The use of counterslope elements is forbidden The smoke channel must allow the recovery of soot or be brushable The smoke c
22. d other solid fuels installation The chimneys must be in compliance with EN 13384 Thermal and fluid dynamic calculation methods UNI 1443 2005 chimneys general requirements UNI 1457 2012 chimneys clay ceramic flue liners UNI TS 11278 2008 Chimneys smoke channels pipes flues metal pipes UNI 7129 point 4 3 3 Fire Department dispositions local rules and prescriptions NATIONAL REGIONAL PROVINCIAL AND TOWN COUNCIL REGULATIONS It is necessary to bear in mind all laws and national regional provincial and town council Standards present in the country the appliance has been installed ENGLISH GLOSSARY CLOSED HEARTH APPLIANCE Heat generator which opening is only allowed through the loading of the fuel during use BIOMASS Biological material excluding the material incorporated in geological formations and transformed into fossils BIOFUEL Fuel produced directly or indirectly by biomass CHIMNEY Vertical pipe with the aim of collecting and expelling the fuel products coming from only one appliance at a convenient height from the ground SMOKE CHANNEL OR FITTING Pipe or connecting element between heat generator appliance and chimney to evacuate combustion products INSULATION Group of set ups and materials used to prevent the transmission of heat through a wall that separates rooms with different temperatures CHIMNEY CAP Device positioned at chimney peak to ease the dispersion of c
23. d and no grates or similar must be positioned it is recommended that the air vent always communicates directly with the installation room even if the air is withdrawn from outside through a pipe The air flow can also be obtained from an adjacent room as long as the flow takes place freely through permanent openings communicating with the outside The adjacent room with respect to the installation room must not be put in depression with respect to the external environment by means of reverse draught caused by the presence of another used appliance or intake device in such room The permanent openings in the adjacent room must comply with the above described requisites The adjacent room cannot be set up as garage storage for combustion material or activity with danger of fire INSULATION FINISHINGS COVERING AND SAFETY RECOMMENDATIONS The coverings independently from the materials from which they are made must constitute a self supporting construction with respect to the heating block and not be in contact with it The cross members and finishings in wood or combustion materials must be positioned outside the hearth radiation area or adequately insulated If coverings in combustion material or sensitive to heat exist in the space above the generator an insulating and non combustible protection diaphragm must be inserted Elements in combustible or inflammable material like wooden furniture curtains etc directly exposed to the hearth radiati
24. e day of the week HOURS 00 24 Adjustment of the hour SET MINUTES 00 59 Adjustment of the minutes CLOCK DATE 1 31 Adjustment of the date MONTH 1 12 Adjustment of the month YEAR 00 99 Adjustment of the year ENABLE CHRONO OFF Activation deactivation of the weekly programmer START PRG1 OFF 00 00 1 ignition time STOP PRG1 OFF 00 00 1 switch off time MONDAY PRG1 OFF yA SUNDAY PRG1 OFF ON OFF Ignition switch off consents for various days SET PRG1 65 80 C Temperature setting for the 1 time span START PRG2 00 10 OFF 00 00 2 ignition time STOP PRG2 00 10 OFF 00 00 Time 2 switch off time MONDAY PRG2 OFF 7 USER MENU 2 SUNDAY PRG2 OFF ON OFF Ignition switch off consents for various days CHRONO SET PRG2 65 80 C Setting room temperature for the 2 time slot START PRG3 00 10 OFF 00 00 3 ignition time STOP PRG3 00 10 OFF 00 00 3 switch off time E PRG3 OFF SUNDAY PRG3 ON OFF Ignition switch off consents for various days SET PRG3 65 80 C Setting room temperature for the 3 time slot START PRG4 00 10 OFF 00 00 4 ignition time STOP PRG4 00 10 OFF 00 00 4 switch off time en PRGA OFF SUNDAY PRG3 ON OFF Ignition switch off consents for various days SET PRG4 65 80 C Setting room temperature for the 4 time slot LANGUAGE ITAL ENGL DEUT FRAN ESPA Selecting the language DISPLAY DISPLAY OFF ON Delayed switch off of the backlighting RESET RESET ON OFF Resets the values modifiab
25. e diameter 1 Automatic exhaust pipe diameter 1 2 Pump head m 5 Max working water pressure accepted bar 2 5 Min working water pressure accepted bar 0 6 Flue gas temperature E 69 8 105 9 Flue gas flow rate 9 5 71153 Boiler class 3 Combustion period h 20 18 Water thermostat field of regulation C 65 80 Water return minimum temperature AG 55 Dimensions of the feeding door mm 576 Lx 236P Yield 92 0 moworummen WATERS gi mbar AT 10K 2751 6 148 Corresponding temperature difference AT 20K 1375 8 74 QExtraflame ENGLISH INTRODUCTION The boilers produced in our establishment are built with attention to the individual components so as to protect both the user and the installer from any accidents It is therefore recommended that after any intervention on the product that authorised staff pay particular attention to the electric connections especially the stripped parts of the wires These must not escape from the terminal board in any situation thus preventing possible contact with the live parts of the wire The instruction manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to other owners or user or is transferred to another place If it is damaged or lost request another copy from the area technician This boiler must be intended for the use it has been specifically made for The manufacturer is exempt from any liability contractual and extracontractua
26. ermostat or be supplied with a cooling circuit set up by the appliance manufacturer The cooling circuit must be activated by a heat safety valve such to guarantee that the limit temperature set by the Standard is not exceeded Connection between the power supply unit and the valve must be free from interceptions The pressure upstream from the cooling circuit must be at least 1 5 bar TYPE OF SYSTEM There are two different types of system Open vessel system and closed vessel system The product has been designed and realised to work with closed vessel systems CLOSED VESSEL SYSTEM System in which the water it contains is not in direct or indirect communication with the atmosphere Generally the closed vessel system has one of the following expansion vessels Pre loaded closed expansion vessel with membrane impermeable to the passage of gases Automatic closed expansion system with compressor and membrane impermeable to the passage of gases Automatic closed expansion system with transfer pump and membrane impermeable to the passage of gases Expansion system without diaphragm GENERALITY The closed systems must have Safety valve Pump control thermostat Acoustic alarm activation thermostat Temperature indicator Pressure indicator Acoustic alarm Adjustment automatic circuit breaker switch Automatic circuit breaker switch block thermostat Circulation system Expansion system Safety dissipation system incorp
27. escriptions Conventional limitations deriving from condominium regulations constraints or contracts INSTALLATIONS ALLOWED Only appliances working in a sealed manner respect to the room or which do not place the room in depression respect to the external environment can exist or be installed in the room where the heat generator will be installed Appliances for cooking food and relative hoods without extractor are only allowed in kitchens INSTALLATIONS NOT ALLOWED In the room where the heat generator will be installed the following must not pre exist or be installed hoods with extractor collective type ventilation pipes Should these appliances be rooms adjacent communicating with the installation room the simultaneous use of the heat generator is forbidden where a risk exists of one of the two rooms being placed in depression respect to the other CONNECTION TO THE SMOKE EVACUATION SYSTEM UNI 10683 2005 Standard SMOKE CHANNEL OR FITTINGS To mount the smoke channels non flammable elements will have to be used ideal for resisting combustion products and their eventual condensing The use of flexible metal and asbestos cement pipes to connect the appliances to the flue is forbidden even for pre existing smoke channels There must be continuity between the smoke channel and the flue so that the flue does not lean on the generator The smoke channels must not cross rooms where the installation of the combustion
28. g valve finds applications in solid fuel boilers as it prevents cold water return into the exchanger Routes 1 and 3 are always open and together with the pump installed on the return they guarantee water circulation inside the biomass boiler exchanger An elevated return temperature allows efficiency improvement reduces formation of combustion product condensation and prolongs the boiler life span Valves on the market have different calibrations Extraflame advises use of 55 C model with 1 hydraulic connections Once the valve calibration temperature is reached route 2 is opened and the boiler water goes to the system via Valve sold as an accessory optional the flow QExtraflame ENGLISH HYDRAULIC SYSTEM BASIC LAYOUT NOTA BENE the drawing in the figure is an example Es o Te ge gm Soa a KEY A Primary air inlet 60mm Smoke exhaust outlet 0 120mm Pump the models envisioned 1 2 T1 3 bar safety drain 1 2 T2 Boiler flow output 1 T3 Boiler return inlet 1 M Manometer Thermometer G Filling system Safety valve discharge VB Balance valve YES System exhaust VMTA Thermostatic mixer valve 55 C IT 15 RECOMMENDED TO CONSULT THE TEMPLATES MANUAL AT FOR FU
29. ge points In case of more heat generators which feed the same system or the same secondary circuit each heat generator must be connected directly to the expansion vessel or system expansion vessels unit altogether dimensioned for the total volume of water contained in the same system or the same independent circuit Where it is necessary to separate the individual heat generator from the expansion vessel or expansion vessels unit a three way tap must be applied on the connection piping between the generator and the vessel in order to ensure in every position the connection of the generator with the expansion vessel or with the atmosphere The expansion vessels the connecting pipes the bleed pipes and drain pipes must be protected from freezing where this phenomenon occurs The solution used for this purpose is described in the design COMMISSIONING CHECKS Before connecting the boiler a wash all system piping in order to remove any residues which might compromise the correct functioning of certain system components pumps valves etc b check to verify that the flue has adequate draft is not narrowed and that other appliances do not discharge into the flue This is to prevent unexpected power increases Only after this control can the flue fitting be mounted between the boiler and the flue A check of the connections with pre existing flues is recommended AUTOMATIC THERMOSTATIC MIXER VALVE MANDATORY The automatic thermostatic mixin
30. hannel must have constant section Any section changes are only allowed at the flue coupling It is forbidden to have other air supply channels and pipes for system engineering especially if over sized transit inside the smoke channels The mounting of manual draught adjustment devices on forced draught appliances is forbidden Extraflame ENGLISH CHIMNEY OR INDIVIDUAL FLUE The chimney or individual flue must respond to the following requisites seal the combustion products be waterproof and adequately insulated in line with the use conditions be realised with materials which resist the normal mechanical stress heat action of the combustion products and any condensate have mainly vertical progress with deviations from the axis not higher than 45 be adequately distanced from fuel or flammable materials through air space or opportune insulation have preferably circular internal section the square or rectangular sections must have round corners with a radius not lower than 20 mm have constant internal section free and independent have rectangular section with max ratio between the sides of 1 5 It is recommended that the smoke pipe be equipped with a collection chamber for solid materials and any condensate situated under the smoke channel inlet so that it can be easily opened and inspected from airtight door
31. iler can respond to external controls If the alarm can be solved by the user once this has been performed the boiler can be re ignited by pressing key 1 In the event of a more complex alarm contact the after sales assistance B SABATO 29 09 2012 18 56 ACTIVE ALARM DENER SABATO 29 09 2012 18 56 gt 9 o E I ALARM MEMORY ALARM TYPE ASPIRATION FAULT Fumes motor fault Contact after sales centre FUMES PROBE Fumes probe failure Contact after sales centre Check pellet feed see Pellet feed adjustment If HOT FUMES High flue gas temperature the problem cannot be solved contact an authorised technician CLEAN CHECK UP 1 2 1 START UP PHASE 2 WORK PHASE The door is not closed correctly The ash drawer is not closed correctly The combustion chamber is dirty The flue exhaust pipe is blocked Check hermetic door closure Check hermetic closure of the ash drawer Check cleanliness of the fumes pipe of the sensor in the primary air channel and the combustion chamber Check for the presence of pellets in the feed box NO The pellet feed box is empty cot Adjust pellet flow see Pellet feed adjustment IGNITION elle ice calibration inadequate Check the procedures described in the Ignition chapter IGNITION hm ilke Take the stove to OF
32. instructions For Italy installation must be carried out by professionally authorised staff Ministerial Decree dated 22 01 08 n 37 Extraflame S p A declines all responsibility for damage to objects and or persons caused by the system SAFETY DEVICES FOR CLOSED VESSEL SYSTEM According to the UNI 10412 2 2009 Standard in force in Italy the closed systems must have safety valve pump control thermostat acoustic alarm activation thermostat temperature indicator pressure indicator acoustic alarm regulation automatic circuit breaker switch automatic circuit breaker block switch block thermostat circulation system expansion system safety dissipation system incorporated with the generator with thermal safety valve self activated whenever the appliance does not have a temperature self adjustment system DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection Whenever the generators lack a device those missing can be installed on the generator flow pipe within a distance no greater than 1m from the machine QExtraflame ENGLISH COMPONENT DISTANCE Temperature safety sensors On the machine or not exceeding 30 cm Missing devices because not as per standard Not exceeding one metre on the flow pipe The domestic heating appliances with automatic feeding must be supplied with a fuel block th
33. l for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use INSTALLATION Installation of the boiler and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations and to those envisioned by the law Installation must be carried out by authorised staff who must provide the buyer with a declaration of conformity for the system and will assume full responsibility for final installation and as a consequence the correct functioning of the installed product It is necessary to bear in mind all laws and national regional provincial and town council Standards present in the country the appliance has been installed Extraflame S p A cannot be held responsible for the failure to comply with such precautions It is recommended to wash all the pipes of the system well before installation to remove any residue that could compromise the correct operation of the appliance During installation inform the user regarding a If water leaks he must close the water supply and promptly inform the after sales technical service b The system working pressure must be checked periodically If the boiler is not used for along period of time it is recommended to contact the after sales technical service to carry out at least the following operations Set the master switch to position 0 Close the water taps of both the heating system and the do
34. le by the user back to the default values QExtraflame ENGLISH SET TEMPERATURE 4 The following menu allows the boiler temperature to be set The possible settings are 65 80 C CONTROLS PROCEDURE SET H20 From the main screen turn P2 to select the SET TEMPERATURE icon Press P2 to confirm Turn P2 to adjust the TEMPERATURE Confirm and memorising by pressing P2 To exit without memorising press key P1 9 SET POWER The following menu allows to set the power Minimum power 1 maximum power 5 CONTROLS PROCEDURE From the main screen turn P2 to select the SET TEMPERATURE icon Press P2 to confirm Turn P2 to adjust the POWER Confirm and memorising by pressing P2 To exit without memorising press key P1 9 9 SET ADJUSTMENTS The set user menu offers the following possibilities automatic manual mode allows enabling disabling the chrono inside the boiler pellet adjustment allows pellet adjustment ENABLE CHRONO The boiler chrono can be enables disables from this menu CONTROLS PROCEDURE ENABLE CHRONO From the main screen turn P2 to select the SET ADJUSTMENTS icon 19 Press P2 to confirm O N Turn P2 to take CHRONO ENABLING to ON Confirm and memorising by pressing 2 To exit without memorising press key P1 9 Extraflame ENGLISH PELLET ADJUSTMENT The following menu allows to adjust the percentage of pellet feed
35. mestic hot water system Empty the heating system and the domestic hot water system if there is risk of freezing COMMISSIONING After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased from When commissioning the product verify that all safety and control devices that the boiler consists of work well All electrical components that make up the boiler must be replaced with original spare parts exclusively by an authorised technical assistance centre thereby guaranteeing correct operation Before leaving the system the staff in charge of commissioning must monitor boiler operation for at least one complete work cycle The boiler must be serviced at least once a year programming it in advance with the technical assistance centre APPROVALS The Extraflame boilers have been designed and realised in compliance with the following Directives UNI EN 303 5 Boilers for central heating Boilers for solid fuel with manual and automatic feeding with a nominal heat output of up to 300 kW Compliance with the Low Voltage Directive 73 23 EEC Compliance with the EMC Directive Electromagnetic compatibility 89 336 EEC FOR SAFETY It is forbidden for the boiler to be used by children or unassisted disabled persons Do not touch the boiler when you are barefoot or when parts of the body are wet or humid The safety and adjustment devices must not be modified
36. ns interventions aimed at reducing degradation from normal use as well as dealing with accidental events entailing the need of first interventions which however do not modify the structure of the system upon which one is intervening or its intended use according to the prescriptions foreseen by technical standards in force and by the manufacturer s use and maintenance booklet Extraflame ENGLISH HYDRAULIC SYSTEM Certain concepts referring to the Italian UNI 10412 2 2009 Standard are described in this chapter As previously described when installing all national regional provincial and town council Standards in force provided by the country in which the appliance has been installed must be complied with SAFETY DEVICES TABLE OF SAFETY DEVICES FOR CLOSED VESSEL SYSTEM AND NOT PRESENT IN THE PRODUCT CIRCUIT BOARD Safety valve Intervenes directly by sending the product into alarm conditions until complete cooling in the case of breakage of flue gas motor pellet Pump control thermostat it is managed by the water feed motor breakage black out if more than 10 seconds no ignition probe and the board program FLOW SENSOR In the event of inadeguate flow it takes the machine to alarm conditions Acousticalarm actiyationthenmostat F2 5 A 250V FUSE STOVES A Protect the machine from violent current drops Water temperatureindicator M 85 C CALIBRATED MECHANICAL BULB WITH MANUAL REA
37. ombustion products into the atmosphere CONDENSATE Liquid products that form when the combustion gas temperature is lower or equal to the water dew point HEAT GENERATORS Appliance which allows to produce thermal energy heat through the rapid transformation via combustion of the chemical energy of the same fuel GATE VALVE Mechanism for modifying the combustion gas dynamic resistance COMBUSTION PRODUCT EVACUATION SYSTEMS Flue gas exhaust system independent from the appliance constituted by a fitting or smoke channel chimney or individual flue and chimney cap FORCED DRAUGHT Air circulation by means of the fan activated by electric motor NATURAL DRAUGHT Draught which is determined in a chimney flue for effect of the volume mass difference existing between smoke hot and surrounding atmosphere air without any mechanical intake aid installed inside it or at its peak Extraflame ENGLISH RADIATION AREA Area immediately near the hearth in which the heat caused by combustion is diffused where no combustion materials must be present REFLUX AREA Area where leaking of the combustion products is verified from the appliance towards the installation room The installation must be preceded by checking the chimneys flues or unload terminals positioning of appliances similarly to Installation prohibitions Legal distances Limitations disposed by local administrative regulations or particular authority pr
38. on must be positioned at a safe distance The appliance installation must guarantee easy access for cleaning the appliance itself discharge gas pipe and flue CHIMNEY CAPS DISTANCES AND POSITIONING Roof inclination Distance between the ridge and the chimney Minimum chimney height measured from outlet B A m H m ja lt 1 85 0 50 m over the ridge gt 1 85 1 00 m from roof en lt 1 50 0 50 m over the ridge gt 1 50 1 30 m from roof lt 1 30 0 50 m over the ridge gt 1 30 2 00 m from roof aie lt 1 20 0 50 m over the ridge gt 1 20 2 60 m from roof PELLETS AND FEEDING The pellets used must comply with the features described by the Standard norm M 7135 DINplus51731 UNICEN TS 14961 Extraflame recommends the use of pellets with use pellet having a 6 mm diameter Open the tank lid and load the pellets using a scoop THE USE OF BAD QUALITY PELLETS OR ANY OTHER MATERIAL CAN DAMAGE YOUR STOVE AND WILL MAKE THE WARRANTY NULL AND VOID RELEASING THE MANUFACTURER FROM ANY LIABILITY QExtraflame ENGLISH SABATO 29 09 2012 18 56 DAY DATE TIME REAL POWER BOILER H20 TEMPERATURE SET POWER ON OFF BUTTON KEY TO GO BACK TO THE ENCODER WHEEL PREVIOUS MENU BY TURNING AND OR PRESSING IT ONE ACCESSES THE MENUS SET SET SET SET SET SET TEMPERATURE POWER ADJUSTMENTS STATUS USER INSTALLER DISPLAY ICONS KEY
39. on and inclination the discharge of the combustion products is assured be positioned ina way to guarantee an adequate dispersion and dilution of the combustion products and however outside the reflux area in which the formation of counterpressures occurs Such area has different dimensions and configuration depending on the covering inclination angle It is therefore necessary to adopt the minimum heights indicated in the figure layouts below The chimney cap must not have mechanical intake means FLAT ROOF SLOPING ROOF 50 cm gt A gt 5m lt 5m JEHHHHHEHE Z REFLUX AREA Extraflame ENGLISH CONNECTION TO EXTERNAL AIR INLETS The appliance must be able to use the necessary air to guarantee regular functioning through external air inlet The air inlets must comply with the following requisites havea total free section of at least 80 cm must be protected by grates metal net or suitable protections as long as they do not reduce the minimum section stated in the previous point and positioned in order to avoid them being obstructed If the combustion agent air is withdrawn directly from outside through a pipe a downward bend must be mounted outside or a protection against the win
40. orated with the generator with thermal safety valve self activated whenever the appliance does not have a temperature self adjustment system 9 9 9 9 9 SAFETY VALVES The load capacity of the safety valve must allow the discharge of a guantity of vapour not lower than O 0 58 kg h where is the useful outlet power to the generator water expressed in kilowatt The diameter of the minimum net transversal section of the valve inlet must not be lower than 15 mm The valve load pressure egual to the calibration pressure increased by the overpressure cannot exceed the maximum exercise pressure of the heat generator The designer must check that the maximum pressure existing in every point of the system does not exceed the maximum exercise pressure of its every component The safety valve must be connected to the highest part of the heat generator or outlet pipes immediately near the generator The length of the pipes route included between the attachment to the generator and the safety valve must not be more than 1 m The connection piping of the safety valve to the heat generator must not be traceable and must not present in any point a QExtraflame ENGLISH smaller section than the inlet of the safety valve or the sum of the inlet sections in case of more valves heading a single pipe The discharge piping of the safety valve must be realised in order not to prevent the regular functioning of the valves and not to cause damage
41. ows to program 4 time spans within a day to use every day of the week The switch on and switch off time can be set in every time slot along with the days of use of the programmed time slot and the desired water temperature 65 80 C RECOMMENDATIONS EXAMPLE The ignition and switch off times must be within the space of Switch on time 07 00 one day from 0 to 24 and not over several days an CORRECT Before using the chrono function set the current day and SONO time Then check that the points listed in the SET CLOCK sub chapter have been followed so that the chrono function works Aside from programming it activate it as well Switch on time 22 00 INCORRECT Switch off time 05 00 CHAPTER WHEN THE WEEKLY PROGRAMMER IS ACTIVE THE RELEVANT ICON WILL LIGHT UP ON THE TO ENABLE THE CHRONO FOLLOW THE INSTRUCTIONS AS DESCRIBED IN THE ENABLE CHRONO m CONTROL PANEL QExtraflame ENGLISH SCREEN ENTRY AND EXPLANATION CONTROLS PROCEDURE Turn P2 to select the icon SET CHRONO Press P2 to confirm m Tur P2 to select SET CHRONO Confirm pressing P2 MONDAY PRG1 Turn P2 to select the desired parameter i i Press P2 to enter modification mode Turn P2 to modify the value Press P2 to confirm and exit Ifyou wish to exit without memorising press key P1 ate Eu tina ana _ STOP First time slot switch off time MONDAY PRG1 gt Day allowed
42. pliance with the Standards in force and to have checked the good functioning of the installed product Once this has been verified the after sales centre will supply all the information for its correct use filling in and delivering a copy of the document which certifies the warranty undersigned by the client EXTRAFLAME S p A assures that all its products are manufactured with top quality materials and with manufacturing techniques which guarantee total efficiency If during normal use of the product defective or badly working particulars should be detected the replacement of such particulars will be free of charge ex dealer who made the sale TERRITORIAL EXTENSION OF THE WARRANTY Italian territory VALIDITY THE WARRANTY IS CONSIDERED VALID ON THE CONDITION THAT 1 The purchaser forwards theinspection report and warranty validation copy 2 filled in completely within 8 days from the date of validation of the warranty The purchase date must be validated by the possession of a valid fiscal document issued by the dealer 2 The appliance is used as prescribed in the instructions manual provided with all products 3 The boiler is installed in compliance with the Standards in force with regard to the prescriptions contained in the installation use and maintenance manual relating to the product by qualified staff in possession of the legal requisites M D n 37 dated 22 January 2008 4 The client is in possession of the documentation which
43. s to persons the discharge must flow immediately near the safety valve and be accessible and visible The diameter of the discharge piping must not however be lower than that of the outlet connection of the safety valve For diameter of outlet connection it is intended the minimum internal diameter on the valve outlet upstream of the eventual internal threading CLOSED EXPANSION VESSEL Warnings check that the preload of the expansion vessel is set to 1 5 bar The vessel maximum exercise pressure must not be lower than the calibration pressure of the safety valve increased by overpressures characteristic of the same valve bearing in mind the eventual level difference between vessel and valve and the pressure generated by the functioning of the pump The capacity of the expansion vessel s is evaluated depending on the total system capacity as results from the project The closed expansion vessels must comply with the dispositions regarding the planning manufacturing evaluation of conformity and use for pressure appliances Intercepting objects or section decreases must be inserted practiced on the connection piping which can be constituted by system portions The insertion of a three way intercepting valve which allows connection between the vessel and the atmosphere for maintenance operations is allowed Such device must be protected against accidental manoeuvres The connection pipe must be realised in order not to present scales or deposits stora
44. the plug from the socket Refer to the electrical diagram to connect the two thermostat cables onto the relative clamps positioned on the rear of the machine one is red and the other one is black STBY clamp The STBY and AUX clamps can be noted in the image below The image is given as an example ATTENTION THE CLAMP MUST BE FITTED WITH A DRY TYPE CONTACT INPUT WITH DRY CONTACT POTENTIAL FREE 3 0 N B INSTALLATION MUST BE PERFORMED BY AN AUTHORISED TECHNICIAN Extraflame MENU STRUCTURE DExtraflame 7 29 09 2012 18 56 4 4 NE Y 1 ON OFF MENU EXIT GO BACK TO THE PREVIOUS MENU PRESS TO ACCESS THE MENU TURN TO SELECT ACCESS MODIFY PRESS TO MEMORISE ENGLISH MENU TEXT VALUE FUNCTION Ol SET TEMPERATURE SET H20 65 80 C Selection of the boiler temperature set point of SET POWER POWER 01 05 Selecting the power Activation deactivation ENABLE CHRONO ON OFF SET ADJUSTMENTS weekly programmer PELLETS 30 20 Selecting the percentage of pellet feed STATUS 1 AND 2 References reserved to the technician of DAY MON SUN Setting th
45. tioning of the product When the appliance is functioning and hot to the touch especially all external surfaces attention must be paid Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period The stove has been designed to function in any climatic condition also critical In particularly adverse conditions strong wind freezing safety systems may intervene that switch the stove off If this occurs contact the technical after sales service and always disable the safety system If the flue should catch fire be equipped with suitable systems for suffocating the flames or request help from the fire service This appliance must not be used to burn waste Do not use any inflammable liquids for ignition During the filling phase do not allow the bag of pellets to come into contact with the product The majolicas are top quality artisan products and as such can have micro dots crackles and chromatic imperfections These features highlight their valuable nature Due to their different dilation coefficient enamel and majolica produce crackling which demonstrate their effective authenticity To clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate the crackles thereby making them show more 6 9 ROUTINE MAINTENANCE Based on the Decree 22 January 2008 n 37 art 2 routine maintenance mea
46. uExtraflame Riscaldamento a Pellet LP30 USER MANUAL ENGLISH INGLESE Extraflame Extraflame We thank you for having chosen our company our product is a great heating solution developed from the most advanced technology with top guality machining and modern design aimed at making you enjoy the fantastic sensation that the heat of a flame gives in complete safety Extraflame S p A ENGLISH 5 TECHNICAL FEATURES sauna AAA een 5 INTRODUCTION ua amaan WARNINGS SA a A A SAE E T A T E AE E E A EE AE T HYDRAULIC SYSTEM INSTALLATION AND SAFETY gn VIG rica 9 SAFETY DEVICES FOR CLOSED VESSEL SYSTEM ponian ynsan 9 DISTANCES OF SAFETY DEVICES ACCORDING TO THE 5 9 TUE OE A alo 10 CLOSED VESSEL SYSTEM asii 10 SAFETY VALVES na 10 1 EXPANSION VES SEL mta onay cane sanayii ar mangalda pls kanma 11 COMMISSIONING CHECKS e me 11 AUTOMATIC THERMOSTATIC MIXER VALVE MANDATORY cnc nn 11 HYDRAULIC SYSTEM BASIC LAVO data 12 INSTANT DOMESTIC HOT WATER PRODUCTION KIT ccscsssssssescssessncassscassssnsscsessesecsesecsssecscsecscancncasencasancassscasassnssssesseseess 13 A 13 A MEM NE NEE I 13 THERMO PRODUCTS FEATURES nana ra arca 13 SAFETY DEVICES lle aaa 14 INSTALLATION ila 14 INSTALLATIONS RR RR RE SOA 15 INSTALLATIONS NOT ALLOWED rire 15 CONNECTION TO THE SMOKE
47. utomatically by the boiler The fi gure below shows the burn pot with underlying opening The company recommends the removal of ash deposits using a suction device at least once every two days or however on the basis of use of the product WEEKLY Cleaning the ash drawer Empty the ash drawer every week or when required It is therefore recommended to remove the ash in the combustion chamber at least once a week using a suitable suction device Extraflame ROUTINE MAINTENANCE ENGLISH In order to guarantee proper functioning and safety of the device the operations indicated below must be performed every season or more often when necessary DOOR ASH DRAWER AND BURN POT GASKETS The gaskets guarantee the tightness of the stove and its consequent good functioning These must be checked regularly if they should be worn or damaged they must be replaced immediately These operations must be carried out by a qualified technician CONNECTION TO THE FLUE Suck and clean the pipe that leads to the flue yearly or anytime that it is necessary If there are horizontal tracts the residues must be removed before they can obstruct flue passage NON CLEANING JEOPARDISES SAFETY IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE RE
48. ving the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased from All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY Thestove must not be used by persons including children with reduced physical sensorial and mental capacities or who are unskilled unless they are supervised and trained regarding use of the appliance by a person responsible for their safety Children must be monitored to ensure they do not play with the appliance Do not touch the stove when you are barefoot or when parts of the body are wet or humid The safety and adjustment devices must not be modified without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the stove even if disconnected from the electric power supply mains It is recommended to position the power supply cable in a way that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are indispensable for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal func
49. with offices in via dell Artigianato 12 Montecchio Precalcino VI guarantees this product for 2 two YEARS from purchase date for manufacturer and material faults The warranty becomes void in case the defect of conformity is not filed with the dealer within two months from date of its finding The responsibility of EXTRAFLAME S p A is limited to the supply of the appliance which must be perfectly installed following the indications contained in the appropriate manuals and books provided with the purchased product and in compliance with the laws in force Installation must be performed by qualified staff under the responsibility of the person entrusting him who will assume complete responsibility for the definitive installation and consequent good functioning of the product installed EXTRAFLAME S p A cannot be held responsible for the failure to comply with such precautions WARNING THE WARRANTY IS VALIDATED ON THE CONDITION THAT The installation and relative connections of the plant have been carried out by professionally authorised staff in total compliance with the Standard in force M D n 37 dated 22 January 2008 in compliance with the Standards in force both national and regional as well as these instructions Testing has been carried out by a qualified technician who assumes the entire responsibility to have verified that the plant has been realised in compliance with the Standard in force by professionally qualified staff in com
50. without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the boiler even if disconnected from the electric power supply mains Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are indispensable for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal functioning of the product Avoid direct contact with parts of the appliance that tend to heat up during functioning Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period 6 9 9 9 9 9 Extraflame ENGLISH The boiler has been designed to function in any climatic condition also critical In particularly adverse conditions strong wind freezing safety systems may intervene that switch the boiler off If this occurs contact the technical after sales service and always disable the safety system If the flue should catch fire be equipped with suitable systems for suffocating the flames or request help from the fire service If the boiler should block indicated by a signal on the display and that is not relative to lack of routine maintenance contact the technical after sales centre THESE BOILERS MUST BE USED TO HEAT WATER TO A TEMPERATURE THAT DOES NOT EXCEED BOILING POINT IN THE CO