1. Depth Monitor XC 1 Md E MIKROFYN SEH Operation Panel M l K R O F Y N CE Shows the remaining depth to On Grade pos Increases the depth of the excavation a e Decreases the depth of the excavation XC 1 Increases the slope of the excavation A U se r S G u j d e Decreases the slope of the excavation 4 56 2 6 5 00 BUCKET 7 Selection of bucket and entrance to MENU Press for 2 sec to enter User MENU A Load and Store the position E Power ON OFF Set On Grade position Press for 2 sec to ZERO set the alarm depth 4 56 2 8 3 90 BUCKET 7 Basic operation instructions 1 Push the E button 2 Place the tip of the bucket on a reference point 3 Push the feo button to set the reference point A A en The display will zero set the actual depth value 2 06 BUCKET 7 MIKROFYN A S BONDOVEJ 16 DK 5250 ODENSE SV DENMARK TEL INT 45 66 17 07 84 FAX INT 45 66 17 07 85 4 Push the o button for 2 sec if you want to zero set the alarm depth Setting the alarm depth Use of XC 1 with laser beam as reference 1 Push the left 4 or a button until the display shows the value desired Basic operation instructions Example If you want to enter a depth of 5 0 m push the left B button until the display shows 1 Push the E button ENRE 2 Make sure that the rotation laser is activated The display to the right indicates 3 Move the Laser Sensor so that it can detect the laser be
2. am EI z 1 The actual depth is 4 56 4 56 A a When the sensor detects the beam the message 2 The alarm depth is 5 00 5 50 BUCKET 7 NEW REF 0 00 PUSH THE L S BUTTON is shown in the lower display and the message LASEr is shown in the upper red display When the sensor approaches the beam the diodes in the 3 The slope is 0 0 no slope 4 The bucket selected is No 7 Di gging wit h slo pe small display will flash slowly in the direction in which the sensor is to be moved in order to detect the laser beam fee on B o pies a 4 56 2A When the diodes flash quickly the sensor is able to detect pee i 5 00 BUCKET 7 the beam Example If you want a slope of 2 where the excavation is getting shallower as the bucket comes nearer the excavator push the right button until the display shows the value 2 0 4 Push the 2 button to set the reference point When the upper display flashes the message LASEr the reference point has been accepted The values of actual depth and alarm depth depends on the actual position of stick and bucket Moving the excavator 1 Put the bucket at a place that can be reached Setting the alarm depth Sean O O ENO 1 Push the left or 3 button until the 2 Push the A button to store the position display shows the value desired The red display will flash to indicate that the Note that the reference point is the laser beam position is stored Example If you want to enter a de
3. ance between the pivot point of the bucket and the edge of the bucket BUCKET LEN 7 Push the right or button until the display shows the distance between the pivot point and the edge of the bucket BUCKET LEN that you measured in 6 8 Push the left 4 button until the display shows BUCKET ANGLE User Menu CALIBRATE BUCKET continued 9 Move the bucket of the excavator to a position where the line between the pivot point of the bucket and the edge of the bucket is in a straight vertical plane MIKROFYN To make sure that the line is in a straight vertical plane we recommend that you use a spirit level In calm weather it is also possible to hold a plumb line P to the pivot point and let it hang straight down BUCKET an Then move the bucket until the leading edge ANGLE touches the string XC 1 10 Push the 0 00 button 29 when the bucket is in the position described above in 9 11 Push the left 2 button until the display shows BUCKET FLAT ANGLE 12 Move the bucket of the excavator to a position where the bucket can be used to level the surface evenly This part of the calibration is used to set how the movements of the bucket are shown on the Main Display The position you put the bucket into will correspond to the middle diode of the seven on the Main Display Your dealer 13 Push the 0 00 button eo when the bucket is in the position described above in 12 The bucket sensor has now
4. arrow and diode starts to light until when the green diodes start to light ON GRADE DEPTH This menu option is used to set when the green diodes diode on the middle of the Small Display and the Main Display respectively start to light The value is the distance from when the green diodes start to light until when the red arrow and diode start to light ALARM HEIGHT This menu option is used to set how high up the pivot points are allowed to get The value is the distance from the lowest pivot point You can save the value by moving the bucket to a desired alarm height and pushing the 0 00 button BUCKET DISP ON This menu option is used to set whether the display is to show the movements of the bucket UNITS ANGLE This menu option is used to set in which unit the angle is measured You can choose between per cent per thousand gon degrees or relative User Menu CALIBRATE BUCKET In order to calibrate the bucket sensor you must input some information about the length and angles of the bucket to the XC 1 System Follow the instructions below to do so 1 Connect the sensor to the Main Display 2 Turn on the Main Display 3 Push the MENU BUCKET button JD and hold it down for about 2 sec You will now enter the User Menu 4 Select the menu option CALIBRATE BUCKET You select a menu option by pushing the left or button 5 Push the right W button to enter the menu option CALIBRATE BUCKET 6 Measure the dist
5. been calibrated 14 Push the MENU BUCKET button D twice to leave the User Menu
6. here is no timeout at this menu option NULLING METHOD This menu option is used to choose nulling method You can choose between STANDARD INTEGRATED LASER and EXTERN LASER For STANDARD the method is as described in the Users Guide in the section Moving the excavator without laser beam as reference For INTEGRATED LASER the method is as described in the Users Guide in the section Moving the excavator with laser beam as reference For EXTERN LASER you must push the L S button 4 when the laser beam is in the middle of the extern laser sensor This method is only used when you use a sensor that is not an integral part of the XC 1 system User Menu BEEP VOLUME This menu option is used to set how loud the Main Display is to beep You can choose between off low normal and loud CONTRAST This menu option is used to set the contrast in the display You can choose between values from 0 to 50 The standard value is 20 The XC 1 has automatic contrast regulation consequently you need not choose a high value LIGHT INTENSITY This menu option is used to set the light intensity in the display You can choose between the values from 0 to 15 The XC 1 has automatic light intensity regulation consequently you need not choose a high value ALARM DEPTH This menu option is used to set when the upper yellow arrow on the Small Display and the yellow diode on the Main Display start to light The value is the distance from when the
7. on to set the reference point When the upper display flashes the message LASEr the reference point has been accepted The values of actual depth and alarm depth depend on the actual position of stick and bucket User Menu To enter the User Menu Push the MENU BUCKET button D and hold it down for about 2 seconds You select a menu option by pushing the left or button You change the value by pushing the right or button The User Menu contains the following menu options DATUM HEIGHT This menu option is used to set the reference height when the 0 00 button o is pressed MEASURE With this menu option you can let the Depth Monitor XC 1 calculate slope height and length in relation to 2 reference points You can choose which of the values is to be shown in the upper red display Push the right 4 or button to select the value To let the XC 1 calculate slope height and length follow this procedure 1 Place the tip of the bucket on the first reference point 2 Push the 0 00 button o to save the first reference point 3 Place the tip of the bucket on the second reference point The upper red display shows the slope height or length according to which value you have selected If you want to work with the calculated slope height and length push the L S button to save the second reference point After saving the second reference point XC 1 automatically leaves the User Menu and returns to working mode T
8. pth of 5 0m below the laser beam push the left button until the display shows the value 5 00 3 Move the excavator and put the bucket at the The display to the right indicates same place where the position above was stored 1 The actual depth is 4 56 v4 J6 A Ba 7 2 The alarm depth is 5 00 2 88 BUCKET 7 4 Push the A button again to load the position 3 The slope is 0 0 no slope 4 The bucket selected is No 7 Use of XC 1 with laser beam as reference Digging with slope 1 Push the right or button until the display shows the slope desired Important The slope you enter to the display must always be the e same as the slope of the rotation laser we Example If you want a slope of 2 where the excavation is getting shallower as the bucket comes nearer the excavator push the right 4 button until the display shows the value 2 0 Moving the excavator 1 Move the excavator to the desired location 2 Move the Laser Sensor so that it can detect the laser beam When the sensor detects the beam the message NEW REF 0 00 PUSH THE L S BUTTON is shown in the lower display and the message LASEr is shown in the upper red display When the sensor approaches the beam the diodes in the small display will flash slowly in the direction in which the sensor is to be moved in order to detect the laser beam When the diodes flash quickly the sensor is able to detect the beam 3 Push the A butt