Control Unit DGC 1 ENG Operating instructions

image

Contents

1. 1 Parameter value Values shown in this manual are fac tory settings Parameter number A MFZOVITOR DIP switches S4 SW1 SW2 SW3 SW4 SW1 Programming mode chapter 5 3 SW2 Display status Chapter 13 SW4 Reset to factory settings chapter 5 4 Fig 2 DIP switches S4 5 4 RESET TO FACTORY SETTINGS Reset to factory settings by changing S4 DIP switch SW4 to ON position and activate STOP and OPEN push buttons for 2 s The display will flash with FAC and program version number will be shown Remember to change DIP switch back to OFF position C Fig 2 Opening rotation direction when door operator mounted as shown in the picture 5 5 OPERATION MODE Parameter number 01 Parameter value 01 Hold to run deadman OPEN Hold to run deadman CLOSE 02 Impulse OPEN Hold to run deadman CLOSE 03 Impulse OPEN Impulse CLOSE 04 Impulse OPEN Impulse CLOSE 0 5 s reverse by stop on force control in opening direction e The door will always run ina deadman mode in programming mode e Value shown after heading is the fac tory setting 5 6 LIMIT TYPE Parameter number 11 Parameter value 00 Mechanical limits micro switches 01 04 Not in use with Ovitors control units 05 Electronic limits rotation direction 1 check fig 2 06 Electronic limits rotation direction 2 e After chan
2. Last 10 errors Press OPEN to select newer error Press CLOSE to select older error If there are no errors the display will show pase By the end of the 10 registered errors the display will show Nakin HEN Upper end Lower end Switch S4 DIP SW2 to OFF position to exit the DISPLAY STATUS Vej mm N AMFZOVITOR 4a FUNCTIONSOFTHELAMPPCB The function of red green traffic light can be chosen according to the following table 0 OFF 1 ON r ray e Red light when door is not open e Green light when door is open e Red light when door is not open e Green light is blinking when door is open e Red light is blinking when door is not open e Green light when door is open e Red light is blinking when door is not open e Green light is blinking when door is open e Red light when the door is opening or closing e Green light when the door is open No light when the door is closed m O r BIE Red light when the door is opening or closing Green light is blinking when the door is open No light when the door is closed Red light is blinking when the door is opening or closing Green light when the door is open No light when the door is closed Red light is blinking when the door is opening or closing Green light is blinking when the door is open No light when the door is closed Red light when the door is not open or closed Green light when the door is open Warning when closing from open limit swit
3. MFZOVITOR Control Unit DGC 1 ENG Operating instructions OVITOR OY SIENITIE 24 FIN 00760 HELSINKI FINLAND Tel 358 0 207 106 600 Fax 358 0 207 106 601 o MFZ J MFZOVITOR De 3 10 11 12 13 14 15 N COTIL OT Sis e ene n 004004440 NASADA NTAS NASAN Ea WEME M b ME REN E 04404034248484 2 Key to symbols General safety instructions Overview of products 4 1 Control unit DGC 1 PCB Installation 5 1 General information 5 2 Mains connection 5 3 Programming the device 5 4 Reset to factory settings 5 5 Operation mode 5 6 Limit type 5 7 Electronic open limit adjustment 5 8 Electronic close limit adjustment 5 9 1 2 open feature Safety edge 6 1 After run 6 2 Extra safety edge 6 3 Wire tighten Advanced settings 7 1 Photocell functions 7 2 Auto closing 7 3 Car wash function 7 4 Run time control 7 5 Reverse time 7 6 Service counter 7 7 Encoder positioning failure Force control 8 1 Force control 8 2 Manual force control open 8 3 Manual force control close 8 4 Force control adaptive settings Inverter LED error codes D15 Display in RUN mode 14 Display status in RUN mode Functions of the lamp PCB li Sn le n r ES Declaration of incorporation of partly completed machinery 19 Danger of personal injury
4. 5 ms 02 Wire tighten 10 ms 03 Wire tighten 20 ms 04 Wire tighten 30 ms 23 24 Fig 3 Pneumatic or electrical safety edge is connected to X3 terminals 23 and 24 X20 Fig 4 Safety edge chosen with parameter 23 is con nected to X20 terminals 3 and 4 PNE or 8k2 Q safety edge PNE or 8k2 Q safety edge NOA Safety edge op BROWN 25 tical GREEN 26 WHITE 27 Fig 5 Optical safety edge is connected to X3 terminals 25 26 and 27 TRANSMITTER BLUE 9 BLUE BLACK D 20 BROWN BLACK 44 RECEIVER Fig 6 Transmitter receiver type photocell is connected to X3 terminals 19 20 21 and 22 Parameter 31 value 02 ZN MFZOVITOR Photocell 2 External photocell connect to X3 terminals 20 21 and 22 7 1 PHOTOCELL FUNCTIONS 00 No photocell 01 Photocell 1 connected 02 Photocell 2 connected 03 Photocells 1 and 2 connected Parameter value 04 07 Only possible with electronic lim its 04 Photocell 1 connected and mounted in the door frame 05 Photocell 2 connected and mounted in the door frame 06 Photocells 1 and 2 connected and photo 1 mounted in the door frame 07 Photocells 1 and 2 connected and photo 2 mounted in the door frame RUN mode is now available by pressing STO
5. Fora three phase current a clockwise rotating field is required e Forapermanent connection an all pole main switch must be used e Fora three phase connection only 3 way automatic circuit breakers 10A may be used Warning Before switching on the controls for the first time a check must be carried out after completing the wiring to ensure that all the motor connections at the motor and at the controls are securely fixed All control voltage inputs are galvanically isolated from the supply gt amp ZA MFZOVITOR 9 Connect mains to terminal X1 1 2 349 COO L1L2L3N PE Fig 1 Terminals for mains connection 5 3 PROGRAMMING THE DEVICE X1 e The door will always run in a deadman mode when programming e Make sure that no emergency stop or other stop is activated before entering programming mode Program the control by open enclosure Without lid Find OPEN CLOSE STOP push buttons and a 4 pole DIP switch on the PCB 94 1 To select programming mode change S4 DIP switch no 1 to ON position 2 Navigation in programming mode is done by STOP pushbutton S1 STOP pushbutton is used to toggle be tween parameter number and parameter value 3 OPEN S2 and CLOSE S3 push buttons are used to se lect parameter number or change the parameter value If display shows RUN these buttons run the door up and down in a deadman mode 4 Parameter explanation
6. The safety instructions must be observed Warning Danger to property The safety instructions must be observed Information e Special information e Reference to other sources of Product liability The function and safety of the equipment is only guaranteed if the warning and safety instructions included in these op erating instructions are adhered to Ovitor Oy is not liable for any personal injury or damage to property that occurs as a result of the warning and safety instructions being disregarded Using the equipment for its intended purpose The DGC 1 controls are designed only for controlling gates and doors Target group Only qualified and trained electricians may connect pro gramme and service the controls Qualified and skilled elec tricians must e Have knowledge of the general and specific and accident prevention regulations e Have knowledge of the relevant electrical regulations e Be trained in the use and care of appropriate safety equipment and clothing e Be capable of recognising the dangers associated with electricity Instructions for installation and connection e Before commencing electrical works the system must be disconnected from the electricity supply Measures must be taken that the electricity supply remains discon nected for the duration of the works e Local safety regulations must be observed e Mains cables must be laid separately from control ca bles o MFZ MFZO
7. used with industrial doors gates and barriers The relevant technical documentation has been compiled in accordance with Annex VII Part B of EC Machinery Directive 2006 42 EC In addition the partly completed machinery is in conformity with the EC 2006 95 EC Low Voltage Directive LVD 2004 108 EC Electromagnetic Compatibility EMC and 2002 95 EC the Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment RoHS The above listed products are delivered according to the following standards to the extent to which they may be applicable EN ISO 12100 1 EN ISO 12100 2 EN 60204 1 A1 EN 60335 1 EN 55014 1 EN 61000 3 2 EN 61000 3 3 EN61000 6 2 EN61000 6 3 EN 60439 1 A1 EN 60439 3 A1 A2 EN 60529 EN 13241 1 EN 60355 1 EN 60335 2 103 EN 13241 EN 12453 EN 12445 EN 12978 SFS Inspecta Sertifiointi OY has issued a certificate ascertaining that the manufacturer s quality system meets the require ments of standard SFS EN ISO 9001 2008 and the general guidelines ABC 200 certificate 1229 04 We undertake in response to a reasoned request to supply it in electronic form to the market surveillance authorities within a reasonable period The party authorized to compile the technical documentation is Ovitor Oy Engineering Manager Sienitie 24 00760 Helsinki Finland The devices are not intended to function independently but as part of an electrically operated machine As regards the installation s
8. 8 1 FORCE CONTROL oid e All mechanical spring adjustments and door limits must be adjusted before selecting force control 00 No force control 01 Force control manual adjustment 1300 1750 rpm 02 Force control manual adjustment 2600 3500 rpm Force control adaptive learning 03 Force control by adaptive learning Ovitor PNP encoder connected to speed input X3 terminal 17 04 Force control by adaptive learning singleturn en coder e RUN mode is now available by pressing STOP e Run the door 2 complete door cycles from closed posi tion without any stop keep pressing OPEN or CLOSE e When learning is finished the RUN will stop flashing in 2 s and the display will automatically switch back to ac tive parameter number e If new adaptive learning is wanted press stop 2 times until RUN is flashing again 8 2 MANUAL FORCE CONTROL OPEN Parameter 41 values 01 or 02 1 Press STOP push button until the parameter value is active flashing 2 If this is the first adjustment turn potentiometer P1 clock wise to max position 3 Press CLOSE to reset for new value and run the door to closed position 4 Press OPEN continuously and turn slowly P1 until the door is stopped Turn a little back The display shows approximately P1 percent value 5 Check that the door can complete full OPEN cycle with out stops 6 By pressing STOP the value is saved and display switch to parameter number
9. P Location of photo will now be learned by running from close to open position The door will stop when the photo is no longer blocked and the control unit will change back to parameter number automatically 7 2 AUTO CLOSING 00 No auto closing xx seconds 1 990 after 99 the value is flashing quickly indicating x10 multiplier for auto close time e g 18 flashing 180 seconds 18 no flashing 18 seconds e If stop or emergency stop is activated more than 5 s with door in open posi tion the auto close will be interlocked to prevent closing Reset of interlock by CLOSE push button or GO FUNCTION close o MFZ MFZOVITOR 7 3 CAR WASH FUNCTION NOTE Available when auto closing is selected by parameter 32 00 Nocar wash function xx Photo active time in 0 1 s e g 15 1 5 s adjustable 1 30 units 0 1 3 s Count down of auto closing time starts only if photo has been activated more than photo active time Door shall be complete closed before start of a new cycle 7 4 RUN TIME CONTROL Both limits must be set before selecting adaptive run time 00 No run time control 01 Runtime 20s 02 Runtime 40s 03 Adaptive runtime RUN position is now available by pressing STOP Run the door from closed to open position without any stop keep press OPEN When run time is learned by open limit the RUN will stop flashing and the display will automatically switch b
10. TROL UNIT DGC 1 PCB X3 DISPLAY EMER STOP O1 ot mm mm RED GREEN 22 lsh uu p sap STOP C zils Ls S100 4 X14 al bis NL OPEN 2 Bue x9 S3 O a ee TA Asoo CLOSE x12 24 X6 SSSSSS oj 2 GO FUNCTION 9 H 1 PROCESSOR X20 n 10 CLOSE LIMIT SW 1110 LOOP RADIO 4 LIL O 3 o 410 3 eH2 DET jg ali swi iy LAMB OPEN LIMIT SW 113 g o Jiz swa a 2 9 mlm fa m o 14 X7 E18 swala 1 PCB o fji 205 X10 1 2 OPEN LIMIT SW 15 all u l3 KE erage 1 16 X19 oe ip a YEL 17 r 6 5 TR1 ee ee SPEED 7 o SENSOR pioto u 20 ar X8 PHOTO 2 44 A RI N RE r 23 EDGE ooh INVERTER ar en 2 xa K1 K2 VERSION WHITE 27 z TSE C538 x o 2 12V 1 5 GND o2 m11 DATA o o I2 zo em i 1123451 j j2l3j4 Al we GPN fo B X1 cee e X2 X23 PULSE IN o 6 X13 L1L2L3N PE PEUV W Key D29 LED CLOSE X1
11. Terminals for mains connection S1 STOP button X2 Terminals for motor connection S2 OPEN button X3 Terminals for command and safety devices s3 CLOSE button X5 Terminal for push buttons in the lid X7 Terminal for radio receiver P1 Potentiometer for Force controls manual settings X8 Terminal for lamp PCB X12 Terminal for Safety photo 1 X13 Terminal for absolute encoder X14 Terminal for LED pad in the lid X20 Extra terminals for safety device X22 Terminals for inverter version X23 Terminals for inverter version D10 LED STOP D12 LED OPEN limit D14 LED CLOSE limit D15 LED Error indication D27 LED Creep D28 LED OPEN 5 1 GENERAL INFORMATION Warning To guarantee that the equipment func tions properly the following points must be ensured e The gate or door is installed and op erational e The MFZOvitor drive motor is installed and ready for operation e The command and safety devices are installed and ready for operation e The control unit DGC 1 is installed Information For the installation of the gate door the MFZ drive motor and the command and safety devices the relevant manu facturer s instructions are to be ad hered J gt 5 2 MAINS CONNECTION Danger To guarantee that the controls function properly the following points must be en sured e The mains voltage must correspond to the voltage stated on the type plate e The mains voltage must be the same as the voltage of the drive e
12. The value must be saved before switching away from programming mode NOTE If no OPEN or CLOSE has been pressed no new value is changed 7 NE MFZOVITOR 8 3 MANUAL FORCE CONTROL CLOSE Parameter 41 values 01 or 02 1 Press STOP push button until the parameter value is ac tive flashing 2 If this is the first adjustment turn potentiometer P1 clock wise to max position 3 Press OPEN to reset for new value and run the door to open position 4 Press CLOSE continuously and turn slowly P1 until the door is stopped Turn a little back The display shows ap proximately P1 percent value 5 Check that the door can complete full CLOSE cycle with out stops 6 By pressing STOP the value is saved and display switch to parameter number The value must be saved before switching away from programming mode 8 4 FORCE CONTROL ADAPTIVE SETTINGS Parameter 41 3 00 Force control delay 08s Stopped by low speed 0 5 Wear limit from initial values 5 01 Force control delay 08s Stopped by low speed 1 0 Wear limit from initial values 5 02 Force control delay 0 8 s Stopped by low speed 15 Wear limit from initial values 5 03 Force control delay 08s Stopped by low speed 2 0 Wear limit from initial values 5 04 Force control delay 0 8 s Stopped by low speed 2 5 Wear limit from initial values 6 05 Force control delay 08s Stopped by low speed 3 0 Wear limit from initial values 7 Up
13. VITOR Regulations and bases for testing For connecting programming and servicing the following regulations must be observed the list is not exhaustive Construction product standards e EN 13241 1 Products without fire resistance or smoke control characteristics e EN 12445 Safety in use of power operated doors Test methods e EN 12453 Safety in use of power operated doors Requirements e EN 12978 Safety devices for power operated doors and gates Requirements and test methods Electromagnetic compatibility e EN 55014 1 Radio disturbance household appliances e EN 61000 3 2 Disturbances in supply systems harmonic currents e EN 61000 3 3 Disturbances in supply systems voltage fluctuations e EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environ ments e EN 61000 6 3 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residen tial commercial and light industrial environments Machinery guidelines e EN 60204 1 Safety of machinery electrical equipment of machines part 1 general requirements e EN 12100 1 Safety of machinery Basic concepts gen eral principles for design Basic terminology methodol ogy Low voltage e EN 60335 1 Household and similar electrical appliances Safety e EN 60335 2 103 Particular requirements for drives for gates doors and windows MFZOVITOR 4 1 CON
14. ack to active parameter number Adaptive run time is learned time 12 5 Below 10 s learned time fixed 1s is added 7 5 REVERSE TIME Reverse time of safety edge in 1 100 s adjustable 0 004 0 99 s XX E g 00 0 004s 05 0 05 s Photo Reverse time of safety edge in 1 100 s adjustable 0 05 0 99 s XX Eg 30 0 3s NOTE This reverse time is also used as speed reversing time and reverse by OPEN push button when the door is closing 7 6 SERVICE COUNTER 00 No service countdown 01 15 open cycles before service for test only 02 5000 open cycles before service 03 10000 open cycles before service 04 20000 open cycles before service Reset for new countdown or selecting value Press STOP to select parameter value Press OPEN or CLOSE to select value Press STOP again min 2s CLR is shown for 2 s in display to confirm new countdown Switch to hold to run a deadman control and display E 04 Service count reaction 00 Display shows E 04 01 If LED pad is mounted Service LED will light when service countdown reach to 0 7 7 ENCODER POSITIONING FAILURE Only available with electronic limits The reaction time for missing positions E 09 00 is 01 2s 02 4s failure reset by hold to run operation to find both limits or limit learning again 03 4s failure is shown shortly resetting automatically NOTE No limit monitoring by selecting value 03
15. ches Red light ap pears before closing mi NI Red light when the door is not open or closed Green light is blinking when the door is open Warning when closing from open limit switches Red light ap pears before closing Red light is blinking when the door is not open or closed e Green light when the door is open Warning when closing from open limit switches Red light starts blinking before closing Red light is blinking when the door is not open or closed Green light is blinking when the door is open Warning when closing from open limit switches Red light starts blinking before closing Mi ki ka li li li B m e MFZOVITOR Dimensions Assembling height Power supply via L1 L2 L3 PE Protections Consumptions Of the control Control voltage Control inputs Control outputs RS 485 A and B Safety chain Input safety edge Relays output Operation temp Storage temp Air humidity Vibrations Type of protection Weight 190 x 300 x 110 vertically at the wall min at a height of 100 mm 400V 50 60Hz power inp max 5 5kW 8 A duty cycle 60 for a max running time of 120s 10A K characteristic max 250 mA 24 VDC max 250 mA protected by self resetting safety for external sensors 24 VDC all inputs are to be connected free of potential min signal time for incoming control command gt 100 ms 24 VDC max 250 mA Only for electro
16. date of set point 0 3 10 door cycles MFZOVITOR Single turn force control NOTE This function is only for special variant of DGC 1 con nected with extern inverter and with electronic limits Parameter 41 4 Opening low speed set point 02 Force control delay 0 4 s Stopped by low speed 3 5 00 10 before open limit Wear limit from initial values 7 01 20 before open limit 01 Force control delay 0 4 s Stopped by low speed 7 0 02 30 before open limit Wear limit from initial values 14 03 40 before open limit Update of set point 0 9 10 door cycles Reaction time for low speed observing about 2 4 s Closing low speed set point e The motive force needed to move 00 10 before close limit the door may increase over time due to wear and tear changes in balanc 01 20 before close limit ing and similar reasons e Once the force needed to move the 02 30 before close limit door has increased to an extent that the motor revolving speed has 03 40 before close limit changed as much as determined by the value wear limit the control notifies with an error code E 08 MEZOVITOR Used when electronic limits are selected No answer from encoder R S AA connections e RS 485 A and B may have interchanged Tense TT j __n tinse ii t rtr rr Ek jll ___n tinse _ _ u zlvxvrmlkilijl _____ Mechanical failure Change the encoder Encoder Failure operating volt e Check c
17. ettings and servicing of the of the machinery the instructions issued by us for the type of instal lation in question must be observed The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of the Machinery Directive Helsinki 16th of June 2010 AT Hannu Pyrh nen Managing Director Ovitor Oy n gt O qAN sa K ISO 9001
18. ging to electronic limits a new power up is needed to start com munication Learning OPEN limit Press STOP push button until the display flashes RUN Run the door to open position Press STOP push button to confirm new OPEN limit The display will indicate OPEN limit symbol for about 2 s and the display will automatic ally switch back to active parameter number e 1 2 OPEN limit cannot be active during programming parameter 16 e Photo in the door frame parameter 31 cannot be active during learning of lim its e When relearning limits parameter 41 and 51 will be reset to factory settings Electronic open limit fine tuning 1309 e Fine tune OPEN limit more open gt values 6 9 less open gt values 1 4 Press OPEN or CLOSE push button to change the value e If the value is changed Press STOP push button Display shows RUN e Try the fine tuning by running the door up and down e Press the STOP push button to save and return to pa rameter value adjustment range is max 0 8 of the door run range e Pressing STOP without value change gt return to pa rameter number ZN MFZOVITOR 5 8 ELECTRONIC CLOSE LIMIT ADJUSTMENT ka e Learn CLOSE limit electronic limits Press STOP push button until the display flashes RUN Run the door to closed position normally 5 cm from the floor Press the STOP push button to confirm new CLOSE limit The display will
19. indicate close limit symbol for about 2 s and the display will automatically switch back to active number e 1 2 OPEN limit cannot be active during programming limits parameter 16 e Photo in the door frame parameter 31 cannot be active during learning of lim its e When relearning limits parameter 41 force control and 51 run time control will be reset to factory settings e Safety edge is disabled in programming mode Electronic close limit fine tuning e Fine tune CLOSE limit more closed gt values 6 9 less closed gt values 1 4 Press OPEN or CLOSE push button to change the value e If the value is changed Press STOP push button Display shows RUN e Try the fine tuning by running the door up and down e Press the STOP push button to save and return to pa rameter value adjustment range is max 0 8 of the door run range e Pressing STOP without value change gt return to pa rameter number o MFZ MFZOVITOR 5 9 1 2 OPEN FEATURE Parameter number 16 Parameter values 00 1 2 OPEN limit not in use 01 Mechanical limit switches value 00 in parameter 11 1 2 OPEN limit switch connected to X3 terminals 15 and 16 Short circuit terminals 15 and 16 if not in use Electronic limits parameter 11 values 5 and 6 OPEN commands to 1 2 OPEN position if X3 terminals 15 and 16 connected ON OFF selector switch is ON 02 1 2 OPEN position 4 8 open 03 1 2 OPEN position 5 8 o
20. nic final switch RS 485 level All input connections must be potential free if safety circuit is interrupted no further electrically powered movement of the drive is possible For electrical safety edge 8 2 kQ pneu matic safety edge tai optical safety edge If inductive loads are switched to e g relays or breaks they must be equipped with corresponding interference measures recovery diode varistores RC modules Operating contact free of potential min 10 mA max 230 VAC 4A Contacts used once for power switch are not able to switch mini power anymore 10 C 45 C 25 C 70 C to 80 non condensing Assembling works with less vibration e g at a masonry wall IP 65 solid installation about 1 8 kg Disposal Waste electrical products and batteries should not be disposed of with household waste Disposal should be carried out according to DI RECTIVE 2002 96 EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equip ment and DIRECTIVE 2006 66 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 6 Sep tember 2006 on batteries and accumulators ZN MFZOVITOR Ovitor Oy Sienitie 24 00760 Helsinki Finland Description and identification of the partly completed machinery Control unit DGC 1 The essential requirements of EC Machinery Directive 2006 42 EC have been applied and fulfilled for the above mentioned machinery to be
21. onnection and supply voltage age e Change the encoder e Check that parameter 11 value is correctly selected Rotation Calculation error direl n 382 e Possible user error Both limits are the same e Encoder error ZAN MFZOVITOR The display will show the status of limits some inputs and error codes in RUN mode During power up the software version is showed shortly e Nothing active 4 chairs symbol e Door is stopped between limits and no errors are found e Open limit active e Normal symbol to help adjustment and fault finding e Close limit active e Normal symbol to help adjustment and fault finding e 1 2 OPEN limit active e Normal symbol to help adjustment and fault finding e STOP active e Normal symbol to help adjustment and fault finding e OPEN push button active e Normal symbol to help adjustment and fault finding e CLOSE push button active e Normal symbol to help adjustment and fault finding e GO FUNCTION active e Normal symbol to help adjustment and fault finding e Photocell 1 active e Normal symbol to help adjustment and fault finding e Photocell 2 active e Normal symbol to help adjustment and fault finding e Safety edge active e Normal symbol to help adjustment and fault finding e Normal symbol indicating door running up e Normal symbol indicating door running down e Notinuse e Error code e Monitoring failure of safety edge if this function is activated e Error code e Doo
22. pen 04 1 2 OPEN position 6 8 open 05 1 2 OPEN position 7 8 open 1 2 OPEN command by a push button connected in X3 ter minals 15 and 16 06 1 2 OPEN position 4 8 open 07 1 2 OPEN position 5 8 open 08 1 2 OPEN position 6 8 open 09 1 2 OPEN position 7 8 open 1 2 open auto close 00 No auto close from 1 2 open position 01 Auto close from 1 2 open position Auto close must be activated in parameter 32 e Safety edge must be connected but not activated before this setup e Ifthe controller has observed a wrong type of edge select the display will show ERR 01 PNE edge 02 8k2 electrical edge 03 Optical edge 04 Notin use with Ovitor s control units 6 1 AFTER RUN 00 No after run gt 00 After run active after run time 0 01 0 3 s Safety edge monitoring will bypass the CLOSE limit and wait for a test impulse from the safety edge If the impulse is not received within time selected with parameter 22 door will be stopped and the control notifies a safety edge failure 6 2 EXTRA SAFETY EDGE 00 No extra safety edge 01 Extra safety edge parallel to the primary safety edge 02 Extra safety edge STOP in the opening direction NOTE Extra safety edge has to be PNE or 8k2 Q and the same type as primary safety edge 6 3 WIRE TIGHTEN Wire tighten parameter set the time that door will reverse after safety edge hits the floor 00 No wire tighten function 01 Wire tighten
23. r is stopped by force control when this function is active e Symbol is also shown if the adaptive force control is not learned when returning to run mode Zon TU MFZOVITOR _ AR e Error code e Door is stopped by run time control e Service counter decremented to 0 e Service the door and reset for new countdown See parameter 58 e Error in the safety edge circuit e Test cycle before close fails e Tacho failure when force control is active e Speed wear failure e Motive force needed to move the door has increased over the wear limit e Check the mechanical condition and balancing of the door Relearn force control e Encoder failure Door started but the position is not changing e Door is stopped after raction time parameter 81 and error E 09 is displayed e Limits must be relearned e EEPROM counter failure or position failure e The door cannot be closed after error on photo or safety edge e Bya special code the door can close one time in hold to run mode Press and hold STOP while press ing 22111 2 CLOSE push button 1 OPEN push button MFZOVITOR e To select DISPLAY STATUS gt close the door and switch S4 DIP SW 2 to ON position e The door cannot be moved when display status is active Electronic counter status The display is flashing between least significant digits and the most significant digits E g 362 and 086 362 1000 086 362086 door openings Press STOP to select next status available

Download Pdf Manuals

image

Related Search

Related Contents

  MANUEL D`INSTRUCTIONS  Délégation des aides à la pierre. Mise en oeuvre du dispositif  User Manual Version 3.1  Samsung LA32B550K1R راهنمای محصول    Peg Perego Pliko Mini Stroller USA User's Manual  USER MANUAL - DiabloSport  This guide covers the use of the Avaya 5620  Mr. Coffee ETC3 User's Manual  