Home
SP600 User Guide V2 (AC&BC Mo... - Spa-Quip
Contents
1. self Diagnostic Error Codes The Spa Power 600 controller has extensive self diagnostic capabilities In the event of a problem it will indicate an error number according to the nature of the problem The error numbers and their meanings are listed below Note When in an error state the alarm can be muted by pushing the AIR AUX button Error 1 H20 Prime Failed This is not necessarily a problem with the SP600 itself but indicates that no water is being detected in the heater housing Prime failed is a special case in that it can be recovered from by pushing a button A push of the pump button will run the pump for 60 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful Error 1 H20 will be indicated on the display again Error 2 Not Used With any Error 3 8 spa operation will stop and not continue until the controller is reset Switched off and on again at the main power supply Error 3 Stuck Button This error indicates that one of the buttons in the touch pad is stuck or has been held down for more than one minute This may be caused by the pool cover pressing on the touch pad or water getting into the touch pad or by damage to the touch pad or its cable Try to reset the spa If there is still a problem then contact your spa pool reseller Se p d S PAYPOWERTCOO Error 4 No Water Sensor 4 zr This error indicates a problem with the optical water sensor in the heater
2. The problem may by caused by the sensor being i disconnected or by damage to the sensor Try to reset the spa If there is still a problem then contact your spa pool reseller A MRa voltage lide Gualined parsannai aN Error 5 Overtemperature This error indicates that the digital temperature sensor in the heater or pool has detected a temperature of 45 C or more This may not be a problem with the SP600 it may be caused by excessive pump use in hot weather or pump failure Turn off the spa and allow time for the water to cool If there is still a problem then contact your spa pool reseller Error 6 Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has operated This is not necessarily a problem with the SP600 It may have occurred from an air lock around the element high temperatures during shipping or failure of the pump This automatic cut out will only reset once the element has cooled below about 38 C The unit must then be reset before it will resume operation Switch off and on at the mains power supply Error 7 Stuck Relay This error indicates a problem with the heater control circuitry inside the unit Contact your spa pool reseller Error 8 No Temperature Data SP600AC 24hr Circ Pump This error indicates a problem with the digital temperature sensor in the heater or pool wall or that both the in heater and in pool sensors are connected
3. at that temperature Manufacturers make no attempt to supply a system that cools water The quickest way to combat the problem is to change the water but even this new water will eventually heat up to the air temperature To combat the heat you can also do the following Turn the set temperature down so the heater does not come on Make sure the spa is shaded from direct sunlight Ifthe nighttime temperature is low leave the cover off the spa to let heat escape but put it back on during the day to keep heat out Page 5 Pump Operation The Pump Button allows the user to control the water pump as desired when using the pool It is used to turn the pump on and off and select speeds if a two speed pump has been fitted 2 pushes AC models or 3 pushes BC models on the pump button cycle the system as follows R Two Speed Pump BC Models Push 1 Pump LOW Push 2 Pump HIGH Push 3 Pump OFF D Single Speed Pump AC Models Push 1 Pump ON Push 2 Pump OFF Note If left on the pump will automatically switch off after 20 minutes Switching the pump on especially to high speed may cause the heater to switch off loadshedding This is in order to keep the total power load to a safe level Indicator Lights AUTO Flashing No Water SPA QUIP T F F PUMP Flashing Sleep Mode l l Li Q HEATER Flashing Error E ale D amp D Pump Button POWER H20 Light The ye
4. Check that only one sensor is connected and that it has not become disconnected or damaged Try to reset S P600 B C 24 h r C rC P um p the spa If there is still a problem then contact your spa pool reseller Spa Quip Australia Pty Ltd Spa Quip Ltd QA Spa Power Equipment Spa Power Equipment a Z www spa quip com au www spa quip co nz mD Sn service spa quip com au service spa quip co nz Os o oo 9 Ph 61 2 9634 5600 Ph 649 415 8622 i re Fax 61 2 9634 5900 Fax 64 2 415 8621 SZ p iz A SPAPOWER Unit 2 13 Hoyle Avenue Cnr Rothwell Ave amp Albany Hwy S 8 SPA CONTROLS Castle Hill NSW 2154 Australia North Harbour Industrial Park Auckland NZ v D A g AA Congratulations on choosing the latest Spa Power 600 control system This controller makes use of the latest technology including innovative optical and digital sensor designs The greater variety of optional accessories user friendly touchpad and reliable components provide you with the most sophisticated controller in its class Temperature Control The Spa Power 600AC BC uses a small circulation pump which runs 24 hours a day to circulate water through the filter and heater The heater is always automatically controlled to maintain the water at the desired temperature as set by the user see below The user can leave the system to look after the spa and know it will be at the correct temperature whenever he or she wants to use it Adjusting Set Tempe
5. h 4 Blower OFF Default State Note If left on this accessory will automatically switch off after 20 minutes If the heater element is on switching on this accessory may cause the heater to loadshed and switch off This is to keep the total power load to a safe level Adjustable Speed Mode If a Spa Power Variable Speed Blower is fitted the spa user has the ability to adjust the blower speed to any desired setting The Up and Down buttons are used to set the desired blower speed Note If the blower is in Full Speed or Oscillating modes then pushing the Up or Down button will put it into Adjustable Speed mode and then adjust the speed NCE Step 1 Press Air Button twice to set Adjustable Speed Mode ar ED Light turns to orange Step 2 Press Up aD to increase speed of blower Step 3 Press Down C v to decrease speed of blower Page 3 Light Operation The multi function Light Button A a P is used to turn the light on and off and select the different operating modes of the Spa Power Variable Colour Light Five short presses of the button will cycle the light as follows 4 Light Button Push 1 Light ON Colour White Push 2 Light ADJUSTABLE Adjustable Colour Mode User selects colour of choice Push 3 Light SLOW CYCLING Cycle through colours slowly Push 4 Light FAST CYCLING Cycle through colours quickly Push 5 Light OFF Default State Note This is a multi function button which perfor
6. llow or blue H20 light indicates if water is present in the heater If no water is detected then the light will flash and the unit will not operate except to run the circulation pump to try to get water to the heater If no water reaches the heater for one minute then an H20 error will occur If this happens then pushing the pump button will run the circulation pump for another minute Jet Pump Light The green Jet Pump light indicates whenever the jet pump is running Heater Light The red Heater light indicates when the heater element is on The heater is controlled automatically to maintain the desired temperature as set by the user Switching on the pump or air blower accessory may cause the heater to switch off loadshed This is in order to keep the total power load to a safe level Page 2 Auxiliary Air Button The Air Button controls an auxiliary air blower Itis used to turn the blower on and off and select different operating modes if a Spa Power Variable Speed Blower SPVSB has been fitted 2 pushes STD or 4 pushes SPVSB of the air button cycles the blower as follows ED Standard Air Blower STD Push 1 Blower ON Push 2 Blower OFF ED Spa Power Variable Speed Blower SPVSB if fitted AIR ED in Push 2 Blower ADJUSTABLE Adjustable Speed ar O ED Orange Light Push 1 Blower ON Full Speed Light ar O CB Light Push 3 Blower OSCILLATING Oscillating Speed p eo Green Pus
7. ms the following 1 Shortpresses of the button activate the light functions as detailed above 2 Holding the button will begin to increase the set temperature of the spa 3 When a Spa Power Variable Speed Blower is fitted and is turned on the button increases the blower speed Adjustable Colour Mode When the light is on pressing the Down button C v will put the light into adjustable colour mode and then sequentially select through all the available colours The last colour setin this mode will be remembered the next time the light is used Indicator Light Asmall red dot in the bottom corner of the digital readout indicates when the light is P turned on If left on the light will automatically switch off after 30 minutes E Safety Notes Before using ensure that the spa pool has been connected to a suitable weather protected outlet socket equipped with a double pole isolating switch which is of the correct rating and complies with the local wiring regulations When installing refer to your local wiring code In particular refer to ECP 2 amp ECP 25 AS NZ and EN 60364 4 1 amp EN 60364 7 1 EU The system must be installed in such a way that live parts are not accessible by a person in the pool If a supply cord is not fitted the system must be permanently connected to fixed wiring through a 30mA or less RCD This appliance is not intended for use by young children or infirm persons without supervision Young child
8. rature The Spa Power 600AC BC gives the user direct control of the pool temperature from the poolside control panel Holding down the Up or Down button will adjust the temperature set point as shown on the digital readout There is a slight delay before the buttons operate to reduce the risk of accidental adjustment The pool temperature will be maintained very close to the set temperature Cy DOWN Decrease the set temperature by 0 5 C per beep Min 10 0 C Increase the set temperature by 0 5 C per beep Max 41 5 C Default Display 3 LU The display normally shows the temperature set point unless the optional in pool temperature sensor is fitted in which case the sensed water temperature is displayed In either case the temperature set point will be displayed while being adjusted as described above Non Default Display Value The non default display value either sensed water temperature or temperature set point can be checked if necessary by pressing the Up amp Down buttons simultaneously SRACWIP seroma ie 8 Sse EER Press both buttons 377 7 wow _ __ i 4 E QD n simultaneously r i L H SP6GOO Page 1 Sleep Time Optional Timeclock If the optional time clock has been fitted sleep mode is used to disable automatic temperature maintenance and filtration in order to reduce the heat contribution from the small circulation pump and ex
9. ren should be supervised to ensure they do not play with the appliance Page 4
10. tend the small circulation pump and optional ozone system life The sleep time setting is done using the digital time clock on the front of the control box See below for setting instructions The spa will wake from sleep mode when any button is pushed to allow it to be used manually as normal If the spa is in use it will not enter sleep mode until 30 minutes after the last manual button push even if the clock is calling for sleep mode On wake up from sleep the system will run the Main pump for 15 seconds and then the blower for 15 seconds to purge the plumbing This prevents any stagnant water from collecting in the pipes if the pool is not used for an extended period To Set Current Time and Day oa 2 Ss Press the RESET button before use NOTE This is optional It will clear the current time and program settings Hold down the CLOCK button and press the DAY button until the correct day is selected Release both buttons Hold down the CLOCK button and press the HOUR button until the correct hour is set Release both buttons Hold down the CLOCK button and press the MIN button until the correct minute is set Release both buttons After setting the weekday and time the seconds will reset automatically and the clock will begin keeping time To Set Programs 1 or Be N Press the TIMER button 1ON will appear at the left side of the display This is the start time of the first programmed sleep block the
11. time you want the spa to enter the sleep mode Press the DAY button to select the days on which this sleep program will operate There are 15 settings to choose from Press the HOUR button to set the hour of the desired time to enter sleep mode Press the MIN button to set the minutes of the desired time to enter sleep mode Now the start time has been set press the TIMER button again 1OFF will appear on the display This is the end time of the first programmed sleep block the time you want the spa to resume normal operation Repeat the same procedure 2 to 4 above until the 1 OFF time is set Be careful to set the same days as used in the 1ON time Your timer gives you up to 8 different programmable periods You can use all 8 settings or as few as you like To Review your set programs press the TIMER button and keep pressing it to advance through each setting IMPORTANT NOTE The MANUAL button on the clock can be used to override the programmed sleep settings It is very important to ensure that the clock is set to AUTO so that the programmed times can operate If the clock is manually set to ON then the pool will stay in sleep mode and THE WATER WILL GO COLD If it is left in OFF then the pool will not enter the sleep mode The clock does not return to AUTO by itself NOTE If the MANUAL button on the clock is pushed the spa will not return to the programmed settings until the next programmed time Page 6 Auto Sani
12. tising Filtration The Spa Power 600AC BC continuously filters the spa pool to ensure the water is clean and crystal clear for each and every spa use A near silent energy efficient circulation pump constantly passes water through the filter and heater only heating when necessary 24 hours a day Since the circulation pump runs all the time except in an error condition and the heater is controlled automatically there is no need for any user controls for these features With the Soa Power 600AC BC there is no need to program any filtration cycles and the noise of a large jet pump running during filtration has been removed My spa is too hot in Summer During summer or warm periods of the year there may be times when the actual water temperature exceeds the desired temperature set by the user e g If the spa is set to heat to 35 C but the actual water temperature has reached 38 C Please consider this a In the winter your spa gets cold because the air temperature is cold To combat this we heat the water and keep the spa covered when not in use If the spa is turned off and the ambient temperature is 15 C eventually the spa water will lose heat until ittoo is 15 C b In the summer when ambient daytime temperature can be 35 C 42 C the spa water naturally heats to the temperature of the air You can turn the heater down even turn the pump off but if the ambient temperature is 35 C 42 C then the spa water will also remain