1. been turned off and must be allowed to cool down to an acceptable level before cleaning Foil sealed plates may remain hot for a number of seconds after sealing and should be handled with care User s Guide 3 4 User s Guide Contents 1 General Description of ApparatuS ssseeseees Page 5 2 Intended function of ApparatuS cccccssssssseeees Page 5 Je WANG EAN AION caa 4 cs secscessaaasecavucansesuauvanssisosceces caeesenens Page 5 4 Types of Consumable eseesssssssssseseecososssssssseeeoe Page 6 5 Operating InstrUctionS sssessseccsseessesosescosecosseeose Page 7 E E Page 10 Ta SC CHIC AION E EE E E A S Page 10 8 Over Temperature Safety Cut Out ssesseeeessssssse Page 10 9 Switching Off the Audible Warning if fitted Page 11 10 Lifting and Moving the Instrument 0 Page 11 11 Warranty and ReturnSs eeesssssssssesesecosoossssesseeee Page 11 12 Declaration of Conformity sessesssseeosssssssssese Page 12 Thermo Fisher Scientific 1 General Description of Apparatus 2 Intended Function of Apparatus 3 Installation Thermo Fisher Scientific General Description of Apparatus Intended Function of Apparatus Installation The Thermo Scientific ALPS 50V provides a safe controlled method of sealing sample plates made from various plastics The sealer is adjustable for both sealing time and temperature and gives a visual countdown
2. display during the sealing process The variable heat sealer can seal deep well plates with various thermal sealing plastic or foil films and may be adapted to seal Microplates and PCR plates by using a suitable plate carrier The variable heat sealer is intended to provide a platform with which to load and thermally seal sample plates to prevent sample loss at high temperature or prolonged periods of storage Various types of plate may be loaded onto a plate carrier and covered by a thermal sealing medium which may be foil or clear plastic The operator may pre set a precise temperature and seal time for the sealing operation Sealing is initiated by pulling down a handle which raises the sample plate into contact with the hot plate The plate sealer detects when the sample plate is in the correct position and starts a countdown timer The countdown is displayed on a three digit LED display When the display reads zero the operator lifts the handle back to the upright position which moves the sample plate away from the hot plate The plate may then be manually removed for further processing The variable temperature sealer should be removed from it s packaging and all internal packaging removed The instrument should be placed on a level surface away from direct sunlight and drafts ensuring access to the power switch on the rear of the unit Ensure that the vents on the back panel are not obstructed 3 1 Mains inlet selection Th
3. Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific Inc Thermo Fisher Scientific Thermo Fisher Scientific WARNING If the unit is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired The unit is intended for indoor laboratory use only at an altitude of less than 2200m above sea level within a temperature range of 18 C to 30 C and a relative humidity range of 20 to 80 non condensing If the instrument is stored outside these ranges it should be left to stand until it equilibrates to within the above limits Ensure the voltage selection switch is set to the correct voltage for the required region See Fig 3 Ensure the correct fuse for the required voltage setting is fitted see Specifications section Do not operate the unit outside the rated power supply range specified There are no user accessible or serviceable parts inside the unit Do not remove or open the unit s casework Before using any cleaning or decontamination method except those recommended by the manufacturer users should check with the manufacturer that the proposed method will not damage the equipment Ensure the unit is only connected to an earthed supply WARNING The hot plate can reach temperatures up to 200 C Care must be taken not to touch it or serious burns may occur The unit will remain hot for a considerable time after it has
4. Mode LED BD a O D 7 Set Temperature Mode LED Fig 3 Voltage Selector Voltage Selector Switch Setto 115V Switch Set to 230V Fig 4 Fig 5 Mains Power Fuse Position Switch Thermo Fisher Scientific User s Guide 9 Cleaning Specification Over Temperature Safety Cut Out 6 Cleaning 7 Specification Temperature Set Point Range Time Set Range Operating Humidity Range Operating Temperature Weight Range Power Supply Power Rating Fuse Mains Input Connector Applicable Standards 8 Over Temperature Safety Cut Out 10 User s Guide The instrument is to be cleaned only by wiping Virkon solution at the manufacturer s guideline concentration No parts are to be autoclaved Equipment Reference ALPS 50V Model No 953 A Specification 125 C to 200 C in 1 C increments 1 to 9 seconds in 0 5 second increments 20 to 80 non condensing 18 C to 30 C 220 x 321 x 425 mm 7 2 kg 100 130V AC 50 60Hz or 220 240V AC 50 60Hz 350 W Max 100 130V T3 15A IEC 127 or 220 240V 1T1 6A IEC 127 IEC 320 FCC Class A CFR 47 Part 15 BS EN 61326 1998 The instrument is protected against a fault condition leading to the sealing plate heating up to a temperature exceeding it s maximum set point Protection is provided by a single use thermal cut out operating in the range 235 C to 240 C In the unlikely event that this cut out should operate it would necessitate the sealer bei
5. Thermo Scientific ALPS 50V User s Guide SCIENTIFIC 2 User s Guide Important This product is designed and constructed to be safe when properly used in accordance with the supplied documentation and when the operating precautions outlined in this document are fully observed IT IS ESSENTIAL THAT THE USER OF THIS MANUAL IS AWARE OF THE POTENTIAL HAZARDS ASSOCIATED WITH THE UNIT AND ITS ACCESSORIES ALL OPERATORS SHOULD BE FAMILIAR WITH THE SAFETY PRECAUTIONS AND WARNINGS GIVEN IN THIS SECTION PRIOR TO ATTEMPTING TO OPERATE THE UNIT IF THE UNIT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED The following symbols are used in this manual CAUTION WARNING HEATED SURFACE The information in this user guide including any apparatus Methods Techniques and Concepts described herein are the property of Thermo Fisher Scientific or its Licensees and may not be copied disclosed or used for any purpose not expressly authorised by the owners there of Since Thermo Fisher Scientific constantly strives to improve all of its products We reserve the right to modify equipment and any user instruction manual without prior notice No part of this instruction manual may be reproduced in any form without the prior consent of Thermo Fisher Scientific Thermo Fisher Scientific ABgene House Blenheim Road Epsom Surrey KT19 9AP UNITED KINGDOM 2007 Thermo
6. e mains voltage selector switch should be checked to ensure that the desired voltage has been set and the correct value of fuse has been fitted see FIG 3 FIG 4 and the specification section The instrument should now be connected to an earthed mains supply with an IEC 320 connector type C13 mains lead ensuring there is sufficient space around it so that the mains connection is not obscured User s Guide 5 Types of Consumables 4 Types of The ALPS 50V is designed to be used with the following Consumable consumables Plate Types Polypropylene polyethylene or polystyrene e Deep well plates without a carrier e PCR Polymerase chain reaction plates with carrier e Microplates with carrier Sealing film types e Foil polypropylene laminate e Clear polyester polypropylene laminate e Clear polymer e Thin clear polymer e Foil laminate e Foil Plate Carriers Enclosed Well Plate Carrier S120530 Open Well Plate Carrier S120529 e Bio Block Plate Carrier S120531 6 User s Guide Thermo Fisher Scientific 5 Operating Instructions Thermo Fisher Scientific Operating Instructions If the instrument has been removed from storage it should be left to reach ambient room temperature For correct operating conditions please see specification section Please refer to FIG 2 for location of user interface components and FIG 4 for the location of the power switch When the instrument is first turned on The LED display s
7. her com www thermo com Thermo Fisher Scientific User s Guide 11 Declaration of Conformity 12 Declaration of 12 User s Guide Conformity The ALPS 50V unit has been designed in accordance with and satisfies the requirements of article 11 of the Low Voltage Directive 73 23 EEC as realigned by 93 68 EEC on the harmonisation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits to the essential requirements of BS EN 61010 1 2001 The ALPS 50V unit has been type tested by EMC Projects Limited a UKAS and CAA approved test facility and UK appointed Notified Body and issued a Certificate of Compliance No 6091 06 to the following EMC standard BS EN 61326 1998 Electrical equipment for measurement control and laboratory use EMC requirements Satisfying the EMC Directive s 89 336 EEC and 92 31 EEC as realigned by 93 69 EEC Declaration I declare that as the Authorised representative that the above information in relation to the supply manufacture of this product is in conformity with the stated standards and other related documents following the provisions of 89 392 EEC Signed Thermo Fisher Scientific United Kingdom Thermo Fisher Scientific Notes Notes Thermo Fisher Scientific User s Guide 13 Notes Notes 14 User s Guide Thermo Fisher Scientific Notes Notes Thermo Fisher Scientific User s Guide 15 Thermo Fisher Sc
8. hows the current setting for sealing temperature which is retained from the last seal A new setting between 125 C and 200 C may be set by pressing the up and down arrow keys The C mode LED lights to indicate that the adjustable field is temperature Pressing the mode switch causes the seal time to be displayed This is also adjustable via the up and down keys in 0 5 Second increments between 1 9 seconds Pressing the mode button again switches back to the sealing temperature adjustment If the up or down arrow keys are held for more than 1 second the key will auto repeat When the desired settings have been set the heat on off button may be pressed to begin heating the sealing plate to the set temperature The heat LED flashes at a slow rate to indicate that the heater is on but not yet up to temperature The heater should heat up to the set point in about ten minutes When the heater is within two degrees of the set point the heat LED will be continuously on and the sealer is ready to begin sealing plates User s Guide 7 Operating Instructions User s Guide 5 Operating Instructions A Typical operating sequence is 1 Switch instrument on and set required sealing time and heater set point temperature for the desired sealing process via the keypad and LED display 2 Enable the heater by pressing the Heat on off button 3 Allow sufficient time for the instrument to reach desired temperature The Heat on off LED
9. ientific ABgene House Blenheim Road Epsom Surrey KT19 9AP UNITED KINGDOM www thermo com
10. ng returned to the manufacturer for repair Thermo Fisher Scientific Switching Off the Audible Warning Lifting and Moving the Instrument Warranty and Returns 9 Switching Off the Some units are fitted with a sounder which give an audible Audible Warning warning at the end of the seal time The sounder is on by default but may be programmed to be on or off To turn the Audible warning off place the sealer in Temperature set mode Set Temperature Mode LED on and simultaneously press the Mode button and the Heat On Off buttons together The display will show 01 to indicate that the audible warning is ON and both Set Temperature Mode and Set Seal Time Mode LEDs will be off Pressing the Down button turns the audible warning OFF The display should now show 00 Pressing the Mode button will save this configuration so that the audible warning is always off and the display will return to the Set Temperature Mode To turn the audible warning back on repeat this process but instead press the Up button to display 01 10 Lifting and Moving WARNING The instrument should be lifted the Instrument AN by holding by the handle Care should be taken when lifting the instrument due to its weight Refer to current Health and Safety procedures 11 Warranty and Thermo Fisher Scientific Returns ABgene House Blenheim Road Epsom Surrey KT19 9AP UNITED KINGDOM 44 0 1372 723456 44 0 1372 741414 fax abgene info thermofis
11. will flash whilst the sealer is coming up to temperature and will remain on permanently when the set point 2 C is reached 4 Load sample plate onto plate carrier and add the sealing film Care should be taken not to touch the heating surface whilst loading the sample plate 5 Grasp the handle with one or two hands as appropriate see Fig 1a 6 Lower handle to thermally compress sealing film onto sample plate see Fig 1b amp 1c 7 When correct clamping pressure is achieved feedback is provided and the timer will count down to zero Care should be taken not to apply more pressure to the handle than is necessary to operate the micro switch 8 On zero seconds the display will flash and an audible warning will sound if audible sounder fitted Release the heater plate from the sealed sample plate by raising the handle to its upper position and review the seal that has been made Failure to raise the handle could ruin the sample plate 9 Remove sealed plate for subsequent processing The seal temperature and time may vary with each type of plate It is recommended that the temperature and time settings for the sealer are reviewed empirically to determine optimum seal integrity Thermo Fisher Scientific Operating Instructions Fig 1c 5 Operating Fig 1a Instructions Fig 2 1 Heat On Off LED 2 Heat On Off Button 3 Down Button Ie 4 Up Button 1 2 ii D 5 Mode Button 6 Set Seal Time