Rinse Water Control System RM
Contents
1. conductivity is usually in the region of 100 to 700 uS 2 7 How can measure the baseline conductivity of my water supply Baseline conductivity of the water supply can be measured with our new compact electrodeless conductivity meter the Stick Meter 5ul It is ideally suited for this purpose and is specifically designed for on site dipping into water supply and rinse tanks giving precise conductivity measurements The meter used to measure baseline conductivity must be recently calibrated as otherwise it may give false reading which will cause problems Fig 2 7 Stick Meter 5Jl Another way of measuring the baseline conductivity is to fill the rinse tank with clean water US and take a reading from the RM 33 in the mode When measuring the baseline conductivity it is essential to ensure that the tank is fairly clean of deposits and chemicals as this value will be needed for the correct setting of the control set point 2 8 How does this apply to the regulation of rinse water in my rinse tank When work parts enter a rinse tank they carry in chemicals from a previous process and this carry in of chemicals causes the conductivity of the water to rise in proportion to the strength of the ionic solution formed The RM 33 monitors the conductivity of the rinse water and opens the water control valve into the rinse tank when a preset level of conductivity is reached The set point will be determined by the type of process and
2. Moranlord Ltd Unit 3H e Northland Business Park Warnham oranlord RH12 3SH Tel 01306 628480 Fax 01306 628481 Email info moranlord co uk http www moranlord co uk RM 33 Rinse Water Control System User Guide July 2012 Contents 1 Introduction 2 Principles of rinse water control using conductivity FAQs 3 Installing the RM 33 4 How the RM 33 operates 5 Setting the RM 33 to suit your process 6 Specifications 7 Options 8 Safety precautions 9 Block diagram Section 1 Introduction The RM 33 is a precision instrument that uses the latest contact free electrodeless sensor technology to control the use of rinse water The control of rinse water gives the following important advantages Lower more consistent water usage and cost More consistent chemical concentration in tank outflow resulting in simpler water treatment process control Lower operator intervention needed to suit changing work patterns The RM 33 is a complete rinse water control system kit including everything required to control the rinse water in a single swill tank The kit comes pre wired and installation time has been reduced to a minimum A specially designed polypropylene encapsulated conductivity sensor is used to measure the concentration of chemical contamination in the rinse tank and a rugged solenoid valve is used to regulate the flow of water The volume of rinse water flow is measured with an integrated digital flo
3. as the control set point and then further refined if more savings are required Guideline Rinse water Contaminant Limits Alkaline cleaner Hydrochloric acid Section 6 RM 33 Specifications RM 33 Kit comprises Control unit wall mounted Enclosure dimensions 180 x 240 x 120 mm HxWxD Power Supply 220V to 250V AC supply Display 0 9999 US temperature compensated conductivity resolution 1uS LCD display External Connections IP68 connectors Mains plug 3amp fused RM 33 DI Kit comprises Control unit wall mounted Enclosure dimensions 180 x 240 x 120 mm HxWxD Power Supply 220V to 250V AC supply Display 0 999 9 uS temperature compensated conductivity resolution 0 1uS LCD display Valve opening set point 0 999 9 uS in 0 1uS increments Set point Hysteresis none solenoid off time is restricted to 10secs min Enclosure IP to IP65 External Connections IP68 connectors Mains plug 3amp fused Conductivity sensor Stainless Steel contacts High temperature all polypropylene construction Cable length 5m Water control valve amp flow meter module 24VDC Burkert Fluid Control Systems type 6213 13mm dia seat direct acting Stainless Steel Integrated digital flow meter Cable length 5m Section 7 Options Audible Alarm Option RM 33 A An option allows the factory addition of an audible alarm which is actuated if the feed water flow drops below 4 litres min as would occur in the ca
4. conductivity Section 2 7 details how this can be done using the RM 33 or the Stick Meter 5Jl 5 2 Adjusting the set point level to suit your process If the set point level is adjusted to be the same conductivity as the incoming water supply then the solenoid will open continuously and no water saving will be made Setting the set point to a higher value will cause the water control valve to close until such time as the rinse water contamination reaches the conductivity level that is set The higher the value above the incoming water conductivity the more contamination will be permitted and the more water will be saved The exact level to be set is very much a matter of judgment where the quality and sensitivity of the processes to rinse water contamination will be the deciding factor The table below is a good starting guide for setting the system initially Generally speaking processes that require conductivity levels of less than 500uS will require demin water in order to meet the uS levels that are shown below unless local water purity is unusually high in that area One way of empirically determining the set point is to set it to a very high value which will effectively shut off the water supply to the tank at a time when it contains clean water and take note of the conductivity reading during rinse tank use Take note of the reading in uS when the contamination has reached a level which is estimated to be acceptable This can be used
5. e socket plugs into the controller while the male connector plugs into the power supply The mains cable comes with 3 amp fused English mains plug by default although other plugs may be fitted upon customer s request Fig3 3c control unit s power supply with power cable Section 4 How the RM 33 operates 4 1 The control panel ELECTRODELESS SENSOR TECHNOLOGY Fig 4 1a RM 33 control panel In order to switch between display modes press the Mode select button the selected mode will be indicated by a red LED All values are displayed on the LCD display The display modes are as follows m 0 M flow meter display mode The RM 33 has an integrated digital flow meter In this mode the amount of water used is displayed in cubic metres and litres US tank conductivity display mode In this mode the conductivity of the rinse tank is displayed in uS US ze _ set point adjust mode In this mode the set point conductivity value at which the water control valve starts dosing the rinse tank is determined gt Oo pa W solenoid open A blue led comes on whenever the conductivity is above the set point to indicate that the water control valve is set to open If the water valve has been shut for less than 10 seconds however the LED will light and the valve will open after a delay to prevent the valve from excessive wear 4 2 Viewing rinse tank conductivity US ml To view the c
6. nduced in the second toroid s windings is in direct proportion to the amount of magnetic coupling and so varies proportionally to the conductivity of the solution This current is amplified and gives an output of conductivity in the solution being measured 2 3 Temperature Compensation A characteristic of conductive liquids is that as their temperature increases so does their conductivity The conductivity measured at a certain temperature therefore has to be compensated for so all readings for different liquids can be compared at a fixed temperature The RM 33 conductivity sensor actually contains signal processing electronics which carry out temperature compensation ensuring very accurate conductivity measurement with variations in water temperature 2 4 What are the units of conductivity Conductivity of water is expressed in the inverse of resistance and the units are Siemens One Siemen represents a very conductive solution and is not usually experienced in most situations so a smaller unit is used the micro Siemen There are 1000 000 uS to 1 Siemen 2 5 How conductive is water Distilled water and de ionised water have low conductivity The conductivity of water purified in this way is about 2 5uS 2 6 What is the conductivity of my water supply The baseline conductivity of the water supply varies from area to area and there is also a small variation over time dependent on the amount of dissolved solids in the water supply This
7. ntrol unit Fig3 3a the control unit Mounting the control unit Mount the control unit at a convenient wall position where it will not be subjected to direct spills of water or chemicals The control unit has 3 mounting points 2 at the lower corners and one on the upper rear of the case Drilling measurements are moulded on the rear of the case The cabinet should be positioned within reach of the water control valve module the tank conductivity sensor and a mains supply However if the cabinet has to be mounted further away than the 5m reach of the cables 5m and 10m extension cables are available for both the water control valve flow meter module and the tank sensor Connections Valve Power Sensor Flow Meter 24V DC Fig 3 3b connections to the control unit The water control valve flow meter module plugs into the 6 pin socket and the conductivity sensor plugs into the 4 pin socket as shown in picture above When plugging in the connectors line up the polarising keyways on the plug and socket push gently in and then turn the locking ring gently clockwise to hold in place Power Supply Connection RM 33 system comes with universal switching power supply which is able to operate on both 110 volts and 240 volts mains voltages The power supply is mounted in separate waterproof box and supplies 24 volts DC The power cable has 3 pin female socket on one end and 3 pin male connector on another end The femal
8. onductivity of the rinse water in the tank US Repeatedly press the Mode select button until the LED lights up The LCD display indicates the level of conductivity in the tank in US 4 3 Adjusting rinse water conductivity set point US To adjust the rinse water conductivity set point at which the water control valve opens to control the tank carry in level uS Repeatedly press the Mode button until the 1 LED lights up Hold the Mode button down for 10 seconds and the uf LED will start to flash Now use the Up Down adjust buttons to change the Set point indicated on the LCD display to the desired value Once the desired set point is reached press the Mode button this value will be stored as the new set point and the water control valve will now be opened whenever this value is reached 4 4 Water flow meter E p How to show the amount of rinse water used Repeatedly press the Mode select button until the ya LED is illuminated The display first shows the cubic metres of water used 1000 s of litres By pressing the mode button again rm LED still illuminated the remaining litres indicated by an L on the display are displayed Once the counter reaches 9 999 999 litres it will roll over to zero If you wish to manually reset the counter to zero litres at any time press the up down buttons simultaneously Section 5 Setting the RM 33 to suit your process 5 1 Establish the baseline water supply
9. rk IMPORTANT Ensure that you fit the solenoid and flow meter in the correct water flow direction marked by arrow on valve see fig 3 6 above The preferable orientation of the valve is with the operating coil uppermost Take care the excessive strain is not placed on the flow meter wire and that there is some slack in the wiring when in its final position Prepare the sockets first with an abrasive paper and ensure they are clean using a suitable solvent Apply a thin even layer of glue to both the pipe and the solenoid adaptor and push both firmly together It is important to ensure that solvent is not allowed to enter the valve body flow meter assembly itself otherwise damage may occur to the valve seating and sealing as well as to the flow meter bearings The module comes pre wired to 5m of cable for connection to the control unit cabinet Extension cables in 5m and 10m lengths are available if necessary depending on the mounting position of the control unit IMPORTANT Remember to wait until the solvent adhesive is thoroughly hardened before pressurising the system The flow meter and valve assembly contain very small orifices which can be blocked by debris in the water system Ensure that the pipe system is flushed through before fitting the assembly 3 3 Installing the Control Unit With the sensor fitted to the tank and the water control valve and flow meter module fitted in the water feed the next step is to install the co
10. se of a failure in the water supply or a tap being closed inadvertently This can offer an important safety feature which can prevent lost work when used with robotic lines The alarm can be cleared by pressing the up or down keys but will sound again after 1 minute if the flow is still below 4 litres min Tank Sensor Extension Cable RM 33 S5 RM 33 S10 Extension cable available in 5 and 10 metre lengths Water control valve Flow meter Extension Cable RM 33 V5 RM 33 V10 Extension cable available in 5 and 10 metre lengths Compact electrodeless conductivity meter Stick Meter 5Jl Small and easy to use conductivity meter designed for on site dipping into rinse tanks and water supply It uses the same electrodeless technology as the RM 33 sensor The meter is autoranging and measures conductivity from 1uS to 500mS and temperature as well Section 8 Safety precautions The RM 33 can be used in environments where toxic and corrosive chemicals are present The user of this system must be aware of dangers of these hazardous substances and take all necessary precautions in this respect when installing and using the RM 33 The RM 33 control unit must be powered by suitable 24 volts DC power supply Ensure that proper cables with the right connectors are used and never try to cut or shorten the mains lead CAUTION To avoid electric shock never place the power supply in places where water could get inside and never open the box of power s
11. ter supply pipe back towards the edge of the tank so that water is forced to mix as much as possible before exiting the tank This can be achieved by fitting an elbow on the end of the inlet pipe A baffle can be used to achieve the same result Water supply angled back towards corner of tank to ensure even dispersion of water Fig 3 1b directing water feed pipe Step 2 Mounting the conductivity sensor to the tank The sensor clamps to the side of the tank tighten the screw so that the sensor is held firmly in place Fig 3 1c tank conductivity sensor clamp lt is possible to add a rubber gasket that goes between the clamp plate and the tank side for increased grip Adjusting sensor submersion depth The sensor head up to the welding joint must be completely submerged in water as shown in picture below The position of sensor mounting clamp can be adjusted by moving the clamp up and down the sensor tube until desired level of submersion is achieved Lowest limit of water level Fig 3 1d lowest possible sensor submersion depth in rinse water 3 2 Installing Water Control Valve amp Flow Meter Module Note Flow Direction Fig 3 2a water control valve amp flow meter module The RM 33 has a pre assembled water control valve and integrated flow meter module Connecting to pipe work The module is terminated at either end with plain 25mm PVC socket unions for insertion into the water feed pipe wo
12. the level of rinse water purity that is required Factors to consider are staining discoloration rusting or contamination of following processes 2 9 What should I use as an initial setting for the RM 33 Section 5 gives details of how to set up the RM 33 Section 3 Installing the RM 33 3 1 Fitting Conductivity Sensor in rinse tank Step 1 Positioning Sensor amp rinse tank considerations The correct positioning of the sensor is critical to ensure the optimal performance from your system In a counter flow system the sensor goes in the clean final swill The sensor should be positioned by the tank outflow or in the case of a counter flow system by the weir into the dirty swill Depending on your tank design this is usually in the corner diagonally opposite the water feed as shown in the diagram below A sensor position on the same side of the tank as the outflow and the opposite side to the water entry is acceptable Water supply Aeration Sensor positioned by Out OW waste Fig 3 1a Typical tank layout It is important that the sensor is not next to the water supply to the tank as this will dilute the reading and cause the water control valve to cycle needlessly The tank sensor comes with 5m of cable to connect to the control unit Extension cables in 5m and 10m lengths are available if necessary depending on where the control unit is to be mounted Water supply pipe lt is good practice to direct the wa
13. upply as it contains live mains voltage Never attempt to connect the control unit directly to the mains and never short circuit the output of power supply as it will result permanent damage to the control unit or power supply If conductivity sensor needs to be replaced use protective clothing to protect your skin from hazardous chemicals and make sure that sensor surface is rinsed after pulling the sensor out of the tank Care should also be taken to avoid electrical shock when it is used in an electroplating environment since although the body of conductivity sensor is made of insulator circumstances can occur when current may track across the wetted surface of the sensor Section 9 Block Diagram Conductivity Sensor Mains input Solenoid valve i 33 a 110 240V to 24V Control board power supply Flow Optional RM 33 A Alarm Peeee eee eee re eee eee eee eee eee eee eee ee eee eee re eee eee ree eee eee eer rere errr rr ere ree eee eee eee eee eee eee RM 33 control unit
14. w meter The system uses low 24 volt power to operate the controller and solenoid valve so that the maximum safety benefits can be gained from use in the plating environment Section 2 Principles of rinse water control using conductivity FAQs 2 1 What is conductivity The conductivity of a liquid is a measure of its ability to conduct an electric current from one point to another In liquids this current flow is made possible by positively and negatively charged ions cations and anions respectively When the liquid conducts a current the ions move to the oppositely charged regions in the liquid so the anions flow to the anode and the cations flow to the cathode This is the basis of electrolytic conduction the greater the number of ions present the greater the conductivity of the liquid The two main techniques for measuring conductivity are contacting sensors electrode and non contacting sensors sometimes known as electrodeless or toroidal 2 2 How does an electrodeless sensor work Electrodeless conductivity measurement does not require any electrode contact with the liquid being measured Instead a pair of wire wound toroidal cores encapsulated in a protective body act as the sensor One toroid is driven with a constant voltage which generates a magnetic field in the liquid In turn the current induced by this magnetic field in the liquid magnetically couples with the second toroid to produce a current This current i
Download Pdf Manuals
Related Search
Related Contents
Introduction to WebFOCUS - ikax.net SRM-SUS-UM-Supplier A.RE.COOP., mode d`emploi - Fédération nationale des sociétés Descargar Documento - Hospital Universitario San Jose Popayan EA993CP-2 (2tonトロリ-ジャッキ) 取扱説明書 Acer 5235 Series Laptop User Manual PDF資料 Bosch TWK 911 UC User's Manual *ARMY TM 10-3930-675-10-1 Copyright © All rights reserved.