MOUNTING AND OPERATING INSTRUCTIONS
Contents
1. Main display area 7 digits for the display of all values displaying all cumulated and actual values 7 2 All display levels and displays in detail Depending on the type of unit the actual range of display may differ from the one shown here Pressing of the push button activates the LC display Switching of levels is achieved by prolonged pressing for 2 sec of push button change of display through short pressing of push button a Energy MWh kWh of GJ gt 165431 Cooling energy MWh GJ or kWh optional 1234567 i Error code flow measurement 98298881 di emi PLR MAX Img Overload times Temperature difference er 0J i86 Operating time GUS e Adr 238 Maximum power display day month year time M Bus primary address permanent change of display BUS pe Ek M Bus secondary address Maximal flow value digits 1 4 day month year time permanent change of display Volume above threshold value 1 only CF 55 30 e M Bus secondary address WU k W qm J digits 5 8 Maximal supply temperature day month year time permanent change of display Threshold value 2 only CF 55 M Bus baudrate optional Pulse weight thermal meter Volume above threshold value 2 only CF 55 Pulse weight water meter 1 2 optional 0205 3 5688 6f Due day values energy month 1 13 GGS 3 WW Ea Due day values cooling energy
2. month 1 13 optional Gigs 3 5773 i Due day values volume month 1 13 Due day values water meter 1 2 month 1 13 optional Soft 3 19 38 Software Version 7 3 Indications concerning special display functions partly optional depending on type of unit 7 31 Energy and volume index display levels 1 and 3 The energy unit is programmed at the factory As a standard energy is displayed in MWh optionally KWh or GJ are possible 7 3 2 Cooling energy display level 1 Display of cumulated cooling energy for energy versions for utilization as combined heating cooling circuits please refer to point 10 for more detailed information 7 3 3 Water meters 1 and 2 display level 1 Display of the meter status of connected supplementary water meters with impulse output using a corresponding option board 7 3 4 Threshold value display display level 1 only CF 55 Representation of threshold value energy share volume and duration in 2 threshold value registers independent from each other tariff register The selection of the threshold value parameters programming of the threshold values and data reset are performed over the M Bus or the optical interface As soon as the energy or volume value is higher than the selected threshold value energy and volume shares are recorded in the threshold value registers The total volume which flowed through the meter during the time the threshold value was exceeded is s
3. 55 is fitted with an integrated data logger for the field analysis of operating parameters in the cooling and heating systems with the following scope of functions e Logger frequency programmable from 1 minute to 7 days e Amount of memory 1008 memory locations per value e Data 6 selectable registers cumulated and instantaneous values Supplementary recording of the fault status Programming and reading of the data logger over M Bus or optical interface 9 Insert optional boards The function range of the calculator may be extended for data communication and data remote display by means of different option boards The following option boards are available M Bus 2 exterior water meters M Bus and energy volume remote display LON 2 exterior water meters Modem 2 exterior water meters Double M Bus only CF 55 RF 2 exterior water meters Details concerning mounting and start up are described in the mounting and operating instructions of the corresponding option boards 10 Special version for use in cooling and combined heating cooling circuits 101 Calculator for utilization in cooling circuits For these product versions the calculator has been identified and programmed at the factory especially for utilization in cooling systems UTILIZATION FOR AIR CONDITIONING Handling LC display and utilization of the option boards is me Ti a coounc ENERGY essentially in accordance with the heat meter
4. all energy and power output related display values M Bus data and remote display impulses being related to cooling energy AIR CONDITIONING SYSTEM The calculator is programmed for installation of the COOLS THE flow metering unit in the warm pipe of the cooling system SYSTEM return of the cooling system A version with programming for the installation of the flow metering in the cold pipe also is available as an option 10 2 Metering unit for utilization in combined heating cooling circuits For these product versions the calculator has been identified and programmed at the factory especially for utilization in air conditio ning systems with combined heating and cooling operation Handling LC display and utilization of the option boards is essentially in accordance with the heat meter The following special charac teristics must be taken into account Boundary conditions for the metering of heating and cooling energy e Heating energy is measured as soon as the temperature difference AT exceeds 0 5 K AT supply temperature Tv return temperature Tr e Cooling energy is measured as soon as the temperature difference AT remains below 0 5 K and supply temperature is less than 25 C LC display e Display of cooling energy is carried out in a ER supplementary register in the Ist display level In order gt air conditioning to differentiate from heating energy a thermometer symbol is displayed simultaneously Aa i
5. corresponding support e Connect wires according to the color code Earth Impulse blue yellow 5 Power supply for calculator Two types of power supply are available As a standard a 6 years battery is supplied 51 6 years battery Lithium Type 2 x lithium 3 6 V AA soldered to an insert board DACAR e Only use original battery e Do not recharge open heat to more than 100 C expose to open flame or immerse in water Do not dispose through domestic waste Dispose according to local regulations Connect battery using plug in connectors e Place battery into the corresponding recess In the calculator casing and engage CAUTION when battery has been disconnected for more than one minute it may be necessary to reset the interior clock Optional 12 years battery on request 5 2 Mains option Mains option Mains voltage 230 V 15 Mains frequency 50 Hz 2 e Maximum power requirement 1 VA Type of cable 2 wires no earth e Cable diameter 4 5 mm 40 mm e Wire section 0 5 mm2 2 5 mm Heat meters with mains power supply must be connected according to installation regulations Power supply must be protected against voltage failures Protective systems circuit breakers must be used in order to ensure safe separation of the unit from the mains power supply if electrical problems should occur breaking current lt 1 A An emergency circuit breaker should fulfill the following
6. requirements e be installed within reaching distance e be clearly recognizable as an emergency breaker separate both wires e clearly indicate on off position The connecting cable of the mains option must be directly connected to the breaker switch Switch off mains power cut off switch e Open casing of calculator and connect the mains power supply to the meter by means of the plug Introduce the mains option board into the corresponding recess in the casing e Pierce the third cable gland from the right and pull through the mains power supply cable Clamp the cable using the tension relieving system Connect wires to terminals No 27 and 28 safe guard against wrong polarity strip cable insulation 8 mm Close casing lid and switch on mains power 6 Startup e Check all functions especially the correct display of temperatures and volume stream e Replace upper part of casing and screw together e Secure screws with users seals supplied plastic seals or wire seals Operating instructions CF 51 55 A heat meter is a measuring instrument used to record energy released in a heating or cooling system The partial compo nents consist of a pair of temperature probes a flow meter and a calculator each component being subject to compulsory calibration for commercial utilization The metering unit records the measurement values of the pair of probes and of the flow meter permitting the display of data over 3
7. Al ACTARIS Sac an Itron Company MOUNTING AND OPERATING INSTRUCTIONS CF 51 55 1 Delivery CF 51 55 1 calculator with battery optionally with mains power supply 1 wall mounting bracket package with material for sealing screws wall plugs mounting and operating instructions Required tools 3 mm screwdriver Crosstip screwdriver 2 General indications Calculator CF 51 55 is a sophisticated electronic measuring instrument The following instructions must be carefully observed in order to ensure correct mounting and to fulfill all safety and guarantee conditions 21 Advice concerning safety Hot water circuits and mains power supplies run under high temperatures and pressures as well as under high voltages When operated incorrectly these may cause serious injuries Due to this the measuring units may only be installed by qualified and trained personnel If the calculator casing is submitted to strong shocks impacts drops from more than 60 cm height or similar stresses the calculator must be replaced Before opening the meter mains voltage optional must be isolated 2 2 CE marks and protective classes Metering unit CF 51 55 fulfills all requirements of EC guidelines and is approved for environmental class C industrial applications according to DIN EN 1434 ambient temperature 5 C 55 C indoors installation storage temperature without battery 10 C 60 C relative atmospheric humidi
8. e Introduce all connecting cables into the lower casing part through the cable glands e Location of the cable depends on the diameter of the cables and taking into account the utilization of option boards and mains power supply and according to the following recommendations Cable glands 1 425 0 75 mm T probe supply 2 425 0 75 mm T probe return 3 6 1 mm mains power supply optional 4 4 25 0 75 mm optional 5 4 25 0 75 mm optional 6 6 1 mm T probe supply optional 7 6 1 mm T probe return optional 8 3 75 0 75 mm flow meter 4 2 Temperature probe Only use pairs of temperature probes with the same serial number Probe cables must not be shortened or lengthened Probes must be mounted according to the guidelines EN 1434 Connecting specification e Connection 2 wire technology for CF 55 also 4 wire technology e Cable diameter 3 5mm 6 5 mm e Maximum wire section 0 2 1 5 mm2 e Type PT100 or PT500 according to DIN EN 60751 Observe nominal value of calculator cf nameplate 4 21 Connecting of temperature probes The following figures 4 2 2 and 4 2 3 and descriptions cover the connection of temperature probes in heating circuits When connecting temperature probes in cooling circuits or in combined heat cooling circuits please observe the following connecting instructions Warm connector Cold connector Heating heat flow circuit suppl
9. ector open drain or static relay Pulse weight observe nominal value of calculator cf nameplate Max pulse frequency CF 51 16 Hz Max pulse frequency CF 55 128 Hz Resistors Ron Roff lt 1509 2 MQ Cable diameter 3 7 5 0 7 5 mm Section of wire 0 2 1 5 mm2 lt 4 3 1 Connecting type US Echo II flow meter e Pierce cable gland 8 of the calculator cf Figure in 411 e Make a loop to resist tension and loop over the corresponding support e Connect wires according to the color code red wire last Voltage Earth Impulse Data red black blue white Remark different versions of US Echo II with supplementary PulsBox are connected box are connected to the calculator as described under Point 4 3 2 Please find details in the documents concerning US Echo Il 4 3 2 Connecting of conventional flow meter Pierce cable glands 8 of the calculator cf Figure in 4 1 Make a loop to resist tension and loop over the corresponding support When connecting pulse generators based on reed contacts standard for volume measuring devices with mechanical metering units polarity must not be observed When connecting electronic pulse generators e g Open Collector please observe polarity Connect the diverse wires according to the terminal connection plan 4 3 3 Connecting type US Echo DN 65 and DN 80 flow meter e Pierce cable glands of the calculator cf Figure in 4 1 e Make a loop to resist tension and loop over the
10. ight and mounting position supply and return of the flow meter must agree with data printed on the nameplate of the CF 51 55 The calculator must be protected against damages caused by shocks or vibrations which may occur at the mounting site e Type and basic value of the temperature probes to be connected must agree with the data indicated on the nameplate e The calculator may be installed optionally on the wall on a cool pipe or directly on the flow meter when type US Echo Il flow meters are being used 3 2 Mounting on the wall If temperatures in the heating circuit are permanently higher than 90 C or if ambient temperature is more than 55 C it is recommended to mount the calculator on the wall Screw the supplied wall support to the wall or fasten it to a cool pipe Set the calculator with an angle of 45 on the support Rotate calculator 45 until it engages 3 3 Mounting on flow meter US Echo II The calculator should not be mounted on the flow meter when ambient temperature is permanently higher than 55 C or when cooling operation is being performed q Rotate 45 Set the calculator with an angle of 45 on the support Rotate the calculator 45 till it engages 4 Connecting temperature probes and flow meter 41 Preparation e Loosen lateral casing screws and remove upper part of casing
11. iy pi 13 due day values end of the month values iiai for cooling energy may be called up in the 3rd display level Cools the system Option boards for remote display Univalioni for healing The option board outputs are marked E for energy and V for volume For this type of product pulses Consumpion o proportional to the cooling energy are output at the volume output marked V leats the system This type of product is programmed for installation of the flow meter in the return pipe of the air conditioning system cold pipe during operation as heating warm pipe during operation for cooling A version with programming for the installation of the flow meter in the supply part also is available as an option Actaris Allmess GmbH Am Vofberg 11 23758 Oldenburg i H Germany tel 49 43 61 62 50 00 For more information www actaris com fax 49 43 61 62 52 50 HE 0036 0 EN 12 07 Copyright 2007 Actaris All Rights Reserved Actaris reserves the right to change these specifications without prior notice
12. nected connection cable is interrupted or broken 2 return temperature probe is not connected connection cable is interrupted or broken 3 negative temperature difference temperature probes were exchanged except in case of combined heating cooling metering 4 Analog to digital converter is broken instrument must be replaced Al 22 Display level operation shut down code a 345 5 7 Al trouble with flow measurement 1 backflow in meter or in pipe system 2 air in the pipe system broken ultrasound probe or very strong deposits on the probes cleaning or inspection required 3 exceeding the maximum admissible flow this message is a warning and does not cause measurement shut down 4 connection cable with flow transponder or connection to the ultrasound probes has been interrupted 5 no flow for gt 24 hours but AT gt 15 K 6 no data communication between calculator and flow meter normal case for 2 wire pulse generators 7 problem with the optional board 7 3 7 M Bus parameters display level 2 Representation of characteristic data for remote data readout over M Bus or optical interface 7 3 8 Due day values display level 3 Representation of 13 end of the month values of the cumulated values for energy volume cooling energy optional and volume of the connected water meters with time stamp and beginning with the value of the previous month 8 Integrated data logger only CF 55 Calculator CF
13. separate display levels Display level 1 billing level cumulated energy and volume display Display level 2 service level actual operating data of the heat meter Display level 3 due day level 13 monthly values of cumulated energy and volume 71 LC display and signification of the segments i eee eee bee ben be TIEM OG D 14 i g O OND 11 12 13 14 ion pea mE FO mE Alarm symbol energy measurement stopped See 7 3 6 Dirty transducer warning energy measurement continued cleaning of the flow sensor is necessary Temperatures appears for temperature related displays or for displays of cooling energy in case of combined heating cooling meters Flow display permanent symbol flow is present flashing symbol no flow Date amp time representation of date and time indications related to time dependent displays e g due day values and maximum values Display level actually selected display level Unit physical unit Decimal point Pulse weight display concerns the pulse weight of the metering unit only CF 51 and CF 55 or pulse weight of exterior connec ted water meters only when a corresponding option board is being used Maximum value appears when maximum values are displayed Operating time appears for operating time display Threshold values only for CF 55 display concerns threshold value tariff function 1 or 2 Water meter 1 or 2 display concerns exterior water meter 1 or 2
14. ty lt 95 absolute altitude lt 2 000 m protective class IP 64 according to DIN EN 60529 protection against dust and splashing EMC protection according to DIN EN 50081 1 2 DIN EN 50082 1 2 double protective insulation ol protective class II according to IEC 60364 4 443 Discarded electronic devices or batteries contained within the calculator must not be disoosed with domestic waste Dispose in accordance to local regulations Dz 2 3 poet important instructions Mounting position shall be selected so that the connecting cable of the flow meter and the temperature probe cables will not lie near mains cables or other sources of electromagnetic disturbances minimum distance 50 cm Cables must not be installed along pipes reaching temperatures above 55 C e Opening of calibration seals will cause the loss of calibration validation and of guarantee A The casing may only be cleaned on the outside with a soft damp cloth Do not use detergents Installation must be carried out according to DIN 4713 or DIN EN 1434 e Some special functions e g when using the tariff and data logger function with CF 55 requires parameters setting of the calculator through M Bus or optical interface lt 3 Mounting the calculator 31 Mounting instructions i Never carry out welding or drilling work near the meter Leave the meter in its original package until all connections insulating painting and cleaning tasks have been performed e Pulse we
15. ummed up in the volume threshold value register Time of excess is recorded in the same way in the time threshold value register lt Function of the energy threshold value register as a function of the selected threshold value Flow Q gt Qi Return temperature Tr gt Tryp Supply temperature Ts gt Ts Power P gt Pih Temperature difference dT gt dT threshold threshold Ts C Q P or dT total energy threshold yx Y total energy X registered X registered po oti X a part of energy part of energy 7 3 5 Maximum value display display level 2 The actual monthly maximum values for power output flow and supply temperature are displayed with the corresponding time stamp Internally 13 monthly maximum values are stored for each case which may be read out over the M Bus or the optical interface The duration of period to assess the maximum values is 60 minutes The duration of period may be varied over the M Bus or the optical interface within a range of 1 min 1440 min 1 day 7 3 6 Operating trouble alarm display level 2 2 In case of operating trouble CF 51 55 displays a symbol K When this trouble alarm appears maintenance should be called CF 51 55 shows detailed information concerning operating troubles in special display levels cf description of display Display level lt operation shut down code AO trouble with temperature recording 1 supply temperature probe is not con
16. y probe return probe Cooling circuit return probe supply probe Combined heating cooling circuit heating supply probe heating return probe e Pierce cable glands C and of the calculator e Pull the supply temperature probe cable warmer line through cable gland 1 and the return probe cable colder line through cable gland e Make a loop to resist tension and loop over the corresponding support cf figure e Connect wires according to the plan of terminal connections 4 2 2 Plan of terminal connections for CF 51 Supply Return Fig probe connection with 2 wire technology 4 2 3 Plan of terminal connections for CF 55 connection with to 4 or 2 wire technology Warning when connecting temperature probes with 2 wire technology to a CF 55 metering unit the connecting terminals must be bridged as shown in the figure Fig probe connection with 4 wire technology Fig probe connection with 2 wire technology 4 3 Flow meter Conventional flow meters with 2 wire connection or US Echo II flow meters with 4 wire connection may be connected to the calculator Using US Echo II flow meters allows for the transmission of trouble warning messages to the calculator over a data cable and for power supply of the ultrasound flow meter through the calculator in addition to transmission of pulses Pulse input specification Pulse input characteristic according to EN 1434 2 Class B Pulse generator reed contact open coll
Download Pdf Manuals
Related Search
Related Contents
Sanitaire SC6070 User's Manual Operating Manual - Automotive Specialty Tools Gigaset SL780/SL785 «Tueur de mots » 取扱説明書 - 三相電機 IS-C1603 Intelligent Controller User Manual Sandisk ImageMate 415753 User's Manual V7 Replacement Battery for selected APPLE Notebooks スイッチシャワー Índice Copyright © All rights reserved.