1. 5 SPRINT IP1546 GB 3 4 Installation with SPRINTBRAS articulated arm For distances between 45 mm and 20 mm remove the Use the SPRINTBRAS articulated arm for doors that open arm F and fasten the arm G to the bracket E with the inwards with deep recess max 185mm spacer and the screw supplied so as to form an angle of 80 90 in relation to the arm M min 650 a mat min 650 a O _ A 340 m E IM G Ss Pdo Varna 2 x VO 3 The fastening distance of the automatic system in relation ee to the door wing can be between 185 mm and 45 mm ass 3 5 Installation of door stop Fasten the door stop supplied as a mechanical opening stop to the floor max 185 Adjust the length of the arms E and F so as to form an an gle of 80 90 in relation to the arm M with the door closed Note the SPRINTBRAS articulated arm is assembled for door wings with left hand or right hand opening arms by rotating by 180 degree s min 650 max 395 SPRINT IP1546 6 4 ELECTRICAL CONNECTIONS BATTERY 12V 1 2Ah Fuse 5A 165 Alimentazione Power supply O
2. 11 12 u DO i Ld Uscita Output SOI el 24V 0 15A RADAR RADAR Attention link up all N C contacts if not used by means of jumpers 4 1 Controls Control Function Description 1 2 CLOSING The closing operation starts when the contact is closed N O AUTOMATIC Always linked A permanent contact enables the automatic closing CLOSING out 1 3 N O OPENING The opening operation starts when the contact is closed 1 t 8 N C REVERSE Linked out if The opening of the contact during the closure operation causes the re SAFETY not in use verse movement re opening 1 9 N C STOP Linked out if The opening of the contact causes the stop of any movement and the not in use exclusion of every normal or emergency functioning 4 2 Output and accessories Output Value Description 4 m Accessories power supply Output for external accessories power supply 24 V 0 15A including accessories connected to the connectors T1 and T2 o _ au 0 15 12 V 1 2 A max Electric lock B B 12V 1 2 Ah Battery kit The automation is fitted with a battery that guarantees the conti nuous working even without a mains supply To charge the batteries connect the mains power and the ba
3. As standard Drive system Non handed in swing or out swing operator Face mounted Power Open Power Close Microprocessor control Built in 3 position switch manual hold open fully automatic Operation Electromechanical operation no risk of oil leakage Integrated damper prevents the door from slamming shut Active range EN3 EN6 Door closes under full control by motor with battery back up in event of power failure Hold open time 1 30 seconds adjustable Motor power consumption 50W Door opening angle 70 95 Opening speed 30 100 Motor Open Motor Close 24 Volt de STANDARD MOTORISATION e Gear motor e Motor Open Motor Close e Control board e Max Door Leaf Weight 70 kg e Power board e Low energy or fully automatic e Transformer e Push and go facility Battery Back Up e On Off Toggle switch N Y D
4. UK OD ADSF DITEC SPRINT SWING OPERATOR INSTALLATION MANUAL STANDARD MOTORISATION MM Gear motor Control board Power board Transformer Battery Back Up 8 Motor Open Motor Close 9 Max Door Leaf Weight 80 kg 10 Low energy or fully automatic 47 Push and go facility 13 On Off Toggle switch Visit Our Online Shop www adsf co uk AUTOMATIC ENTRANCE SPECIALISTS Includes Silver Grey Cover On Off Rocker Switch Push Or Pull Arm Max Door Leaf Weight 70 kg we open the doors for you A Wa Y Fig 1 90 450 60 260 168 Fig 2 SPRINT IP1546 GENERAL SAFETY PRECAUTIONS This installation manual is intended for professionally competent personnel only Installation electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulations Before installing the product carefully read the instructions Bad installation could be hazardous The packaging materials plastic polystyrene etc should not be discarded in the envi ronment or left within reach of children as these are a potential source of hazard Before installing the product make sure it is in perfect condition Do not install the product in an explosive environment and atmos phere gas or inflammable fume
5. Wai for 2 5 s Adjust TC t23s FA table adjust VM SPRINT IP1546 5 START UP Attention the operations relating to point 5 4 are performed without safeties The trimmer can only be adjusted with the automation idle 5 1 Set DIP1 on the basis of the type of force to be set DIP2 on the basis of the electric lock installed DIP3 OFF and DIP4 on the basis of the opening direction 5 2 Adjust the VM trimmer to 1 4 rotation and TC to the maximum 5 3 Make a jumper for the safeties 1 8 1 9 5 4 Connect the power supply then with commands 1 2 and 1 3 check the automation is working correctly With the VM trimmer adjust the automation speed Attention upon each switch on the first opening or closing movement is made at low speed and allows the stop positions to be noted acquisition 5 5 Evaluate the risks install and connect all the necessary safety devices 1 8 1 9 to the control panel and check their functioning 5 6 If required adjust the automatic closing with the TC make a jumper for contact 1 2 5 7 If Push amp Go opening required set DIP3 ON Attention the Push amp Go function cannot be activated if DIP2 ON 5 8 Connect any accessories and check they are functioning 5 9 If the automation encounters an obstacle during closure it is detected and the automation opens again If the automation encounters an obstacle during opening it is detected and the automation stops In the subsequent operation the
6. for the safe installation use and maintenance These instruction must be kept and forwarded to all possible future user of the system This product must be used only for that which it has been ex pressly designed Any other use is to be considered improper and therefore dangerous The manufacturer cannot be held re sponsible for possible damage caused by improper erroneous or unreasonable use Avoid operating in the proximity of the hinges or moving mechanical parts Do not enter the field of action of the motorised door or gate while in motion Do not obstruct the motion of the motorised door or gate as this may cause a situation of danger Do not allow children to play or stay within the field of action of the motorised door or gate Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary activation of the motorised door or gate In case of break down or malfunctioning of the product discon nect from mains do not attempt to repair or intervene directly and contact only qualified personnel Failure to comply with the above may create a situation of danger All cleaning maintenance or repair work must be carried out by qualified personnel In order to guarantee that the system works efficiently and correctly it is indispensable to comply with the manufacturer s indications thus having the periodic maintenance of the motori sed door or gate carried out by qualified personnel I
7. EC Annex Il sub B Manufacturer DITEC S p A Address via Mons Banfi 3 21042 Caronno P lla VA ITALY Herewith declares that the electromechanical automatic system for swing doors series SPRINT is intended to be incorporated into machinery or to be assem bled with other machinery to constitute machinery covered by Directive 98 37 EC is in conformity with the provisions of the following other EEC directives Electromagnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC and furthermore declares that it is not allowed to put the ma chinery into service until the machinery into which it is to be incorporated or of which it is to be a component has been found and declared to be in conformity with the provisions of Directive 98 37 EC and with national implementing legislation Caronno Pertusella Fermo Bressanini SPRINT IP 1546 1 TECHNICAL DETAILS SPRINT SPRINTJ Power supply 230 V 50 60 Hz O 120 V 60 Hz O Absorption 0 2A 0 4A Maximum torque 25 Nm 25 Nm Opening time min 7 s 90 min 7 s 90 Closing time max 3 s 90 max 3 s 90 Intermittence S2 30 min S2 30 min S3 80 S3 80 Accessories power supply 24 V 0 15A 24 V 0 15A Operation type Motor opening Motor opening Motor closing Motor closing Temperature 20 C 55 C 20 C 55 C batteries 10 C 50 C batteries 10 C 50 C Degree of protection I
8. P12D IP12D Control panel 165 165 __ Limit dimensions Applications 150 kg m door wing width kg door wing weight 100 kg rd Recommended dimensions 50 kg 2 REFERENCE TO ILLUSTRATION The given operating and performance features can only be gua ranteed with the use of DITEC accessories and safety devices 2 1 Standard installation references fig 1 1 Gearmotor 2 Radar 3 Connect to the power supply by means of the appropriate plug Connection to the grid is made with independent channels and separated from the connections to the command and safety devices 4 Mechanical opening stop 2 2 Automation references fig 2 5 Control panel 6 ON OFF switch 7 Casing 8 Arm support 9 Base plate 3 INSTALLATION Unless otherwise specified all measurements are expressed in millimetres mm 3 1 Preliminary checks 3 2 Installation with articulated arm Use the articulated arm for doors that open outwards seen from automation side min 550 O Remove the casing and fasten the automation on the wall respecting the measurements indicated in the figure refer to the hinge axis Check the stability the weight of the door wing and the regu larity of the movement without friction if necessary reinforce the fram
9. arth system made in accordance with applicable safety regulations During installation maintenance and repair interrupt the power supply before opening the lid to access the electrical parts A To handle electronic parts wear earthed antistatic con AGA ductive bracelets The motor manufacturer declines all responsibility in the event of component parts being fitted that are not compatible with the safe a correct operation For repairs or replacements of products only original spare parts must be used The installer shall provide all information relating to automatic manual and emergency operation of the motorised door or gate and provide the user with operating instructions MACHINERY DIRECTIVE Pursuant to Machinery Directive 98 37 EC the installer who motorises a door or gate has the same obligations as the ma nufacturer of machinery and as such must prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive The technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the motorised door draft the EC declaration of conformity in accordance with Annex II A of the Machinery Directive and deliver it to the customer affix the CE marking on the power operated door in accordance with point 1 7 3 of Annex of the Machinery Directive For more information consult the Technical Manual Gui
10. delines available on Internet at the following address www ditec it APPLICATIONS Service class 5 minimum 5 years of working life with 600 cycles a day Applications HEAVY DUTY For vehicle or pedestrian acces ses to institutional complexes with very intense use Performance characteristics are to be understood as referring to the recommended weight approx 2 3 of maximum permis sible weight A reduction in performance is to be expected when the access is made to operate at the maximum permis sible weight Service class running times and the number of consecutive cycles are to be taken as merely indicative having been statisti cally determined under average operating conditions and are therefore not necessarily applicable to specific conditions of use During given time spans product performance characteristics will be such as not to require any special maintenance The actual performance characteristics of each automatic access may be affected by independent variables such as friction balancing and environmental factors all of which may substantially alter the performance characteristics of the automatic access or curtail its working life or parts thereof including the automatic devices themselves When setting up specific local conditions must be duly borne in mind and the installation adapted accordingly for ensuring maximum durability and trouble free operation DECLARATION BY THE MANUFACTURER Directive 98 37
11. ds have not been installed The goods are returned as complete items All packaging fixing kits and instructions are as new A re stocking charge of 15 will be imposed Send to ADSF UK LTD Unit 3 Millers Court Windmill Road Kenn Clevedon BS21 6UL PLEASE SIGN BELOW TO ACCEPT OUR TERMS AND CONDITIONS Y ERREKA ENTRANCE N Registered Office 20 22 Bedford Row London WCIR 4JS Registration No 5287944 VAT No 811346 362 SPECIALISTS UK OD NBS Specification ADSF Sprint swing door operator ADSF Sprint swing door operators are particularly suitable for use in a variety of door applications such as retail hotels offices airports stations hospitals schools industrial and commercial premises Internal light duty use only All equipment is designed to meet the rigorous safety requirements of BS 7036 1996 and is installed by Automatic Door Suppliers Association ADSA accredited engineers Standard details for ADSF Sprint swing door operator Supplier ADSF UK LTD Product reference ADSF Sprint Door Operator Door configuration Double and single Door leaf width 700mm 1100mm Door Weight 70Kg Finish Silver Grey Safety features Emergency opening in the event of a power failure Door can be used with push and go facility The operator can be connected to a building fire alarm system to either remain open or closed Dimensions 80mm high x 90mm deep x 450mm wide Guidance for ADSF Sprint swing door operator
12. e Any door closes must be eliminated or completely cancelled Attention check the correct working in the case of installation on doors that separate environments with different pressures SPRINT IP1546 44 max 30 Assemble the push arm without tightening the travel 3 3 i Installation with sliding arm TN eel ASE OE AOA Unig Use the sliding arm for doors that open inwards seen from it is inserted in the housing of the arm support automation side Push Arm B A min 650 Slide Arm Opening in Remove the casing and fasten the automation on the wall respecting the measurements indicated in the figu Fasten the bracket B to the door p g 9 re refer to the hinge axis Push Arm B ae BS eS eS C ial OPEN Slide Arm Opening in With the door closed adjust the arm and tighten the screws A Bore the guide C and fasten it to the door de Slide Arm Opening in Push Arm B Insert the sliding block D of the sliding arm in the guide C Fasten the arm to the automation ensuring it is inser ted in the housing of the arm support Insert the lid E and the two heads F min 10
13. fety conditions example passage of disabled persons set TC gt 5s set MS 5s 90 DIP2 Electric lock function permanent thrust current The drive im pulse is given at the same time as the start of the opening operation With the automation closed there is a With the automation closed before the opening operation a closing thrust is introduced at the same time as the drive impulse During the closing operation the speed increases slightly to ensure the correct closing of the electric lock DIP3 Push amp Go Disabled Enabled DIP4 Direction selection being examined The opening direction is intended by viewing the automation from the side Left hand opening Right hand opening 4 5 Signals LED ON Flashing POWER ALARM 24 V power supply Encoder automation fault 4 6 Doors requirements for handicapped persons use If the SPRINT automation is used on doors for the passage of disabled persons adjust the VM trimmer so that the opening and closing times excluding deceleration are the same as or greater than those indicated in the table Door wing weight Door wing length 50 kg 60 kg 70 kg 80 kg 90 kg 750 mm 3 0s 3 1 Ss 3 2 S 3 38 3 58 850 mm 3 1s 3 18 3 2 S 3 4 S 3 6 S 1000 mm 3 28 3 4 s 3 7 S 4 0s 4 2s 1200 mm 3 88 4 2s 4 55 48s 5 1158 Make the adjustments indicated in the figure OPENING CLOSING X
14. n particular regular checks are recommended in order to verify that the safety devices are operating correctly All installation maintenance and repair work must be documented and made available to the user Technical Help Line 08700 434512 10 OFF ON Installer X TEAR OFF AND DELIVER TO USER dub RETURNS NOTE Please include this form with any items returned CUSTOMER DETAILS CONTACT NAME ADDRESS ACTIONNEEDED NEEDED QUANTITY INVOICE No Replacement ACTION NEEDED _ Fault Description Date Purchased Ordered Credit Repair TERMS AND CONDITIONS 1 Goods will not be accepted back without a valid Returns number 2 Please ensure the relevant invoice is placed inside the component box with a detailed fault report 3 Please give as much detail as possible regarding your fault report Reports like DEAD or FAULTY will not be accepted 4 All items including swing operators must be sent back complete we will not accept individual internal components for repair or replacement 5 Goods found not to be faulty may incur a testing fee handling charge of 10 00 plus vat 6 Physically damaged items will be rejected 7 Items may be replaced with equivalents if originals are not available 8 These items may be repaired or replaced 9 Refunds and credit notes are issues at Auto Doors amp Shopfronts discretion as point 10 below 10 Re stocking The goo
15. obstacle is considered as a new stop point until it is removed 6 TROUBLESHOOTING Problem Possible cause The automation does not open Power failure and close Remedy Make sure electric control panel is powered POWER ALARM led on Disconnect accessories from terminals 0 1 with 24 V voltage and connect them again one at a time Check terminal 9 of the control panel Make sure the wing can move freely Check terminal 8 of the control panel Check the clean state and correct working of the photocells and safety devices Make sure the radar is not subject to vibrations nor carrying out false detections or detecting mo ving objects within its range of action Automatic closing does not work Check 1 2 jumper The radars are unstable or detect moving Make sure the radar is not subject to vibrations objects nor carrying out false detections or detecting mo ving objects within its range of action Encoder not working Replace encoder Accessories short circuit ISTOP contact open The door is blocked by bolts and locks Safety contacts are open me safety devices are activated The door opens but does not close The radars are activated The door opens by itself The door opens closes briefly and then stops POWER ALARM led flashing Inverted motor wires Check motor wires POWER ALARM led flashing Some friction is present Check manually
16. s are a serious hazard risk Before installing the motors make all structural changes relating to safety clearances and protection or segregation of all areas where there is risk of being crushed cut convoyed and danger areas in general Make sure the existing structure is up to standard in terms of strength and stability The motor manufacturer is not responsible for failure to use Good Working Methods in building the frames to be motorised or for any deformation occurring during use The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises sys tem operating logic and the forces developed by the motorised door or gate The safety devices must protect any areas where the risk exists of being crushed cut convoyed or where there are any other risks generated by the motorised door or gate Apply hazard area notices required by applicable regulations Each installation must clearly show the identification details of the motorised door or gate Before making power connections make sure the plate details correspond to those of the power mains Fit on the electrical system an omnipolar disconnection switch with a contact opening gap of at least 3 mm Check there is a differential switch and adequate overcurrent protection upline from the electrical system When necessary connect the motorised door or gate to a reli able e
17. that the wing can move freely Make sure there is no dirt or grit under the wing The batteries are inefficient Check the battery fuse Remove the mains power supply and check the ef ficiency of the battery making some operations If insufficient replace it 7 MAINTENANCE SCHEDULE every 6 months Remove the power supply and batteries and position the ON OFF switch 7 in the OFF position Clean and lubricate the moving components Check that all securing screws are well tightened Check all wiring Check battery efficiency Replace the power supply and batteries and position the ON OFF switch 7 in the ON position Check for the stability of the door and that the movement is steady without friction Check the condition of the pintles or hinges Check that all controls and safety devices are properly functioning ATTENTION For spare parts see the spares price list 9 SPRINT IP1546 OPERATING INSTRUCTIONS FOR SPRINT SWING DOORS AUTOMATION RELEASE OPERATION In the event of maintenance malfunctioning or emergency if you want to disconnect the automation set the automation switch to OFF and move the door manually If the door does not have an electric lock use the appropriate key to release it GENERAL SAFETY PRECAUTIONS The following precautions are an integral and essential part of the product and must be supplied to the user Read them carefully as they contain important indications
18. tteries at least 30 seconds before starting the system To disconnect the control panel you must disconnect the power supply and the batteries Attention the batteries must always be connected to the control panel for char ging Periodically check the efficiency of the batteries Note the operating temperature of the rechargeable batteries is approximately 5 C 40 C The batteries should be installed inside a climatised environment to ensure the correct functioning of the product T1 T2 Connectors for connection to external command accessories example RER radar Attention to use RER radar position the dip switch of the radar in the DX position ON OFF switch Switch for activating deactivating When activating ON posi tion the first operation is carried out with the acquisition of the stop positions When deactivating OFF position the line power supply and the batteries are disconnected from the control panel 7 SPRINT IP1546 4 3 Trimmer Description MIN MAX TC Automatic closing time Adjust the time that passes between the end of the opening manoeuvre and the start of the automatic closing manoeuvre Os 30s Note with DIP1 ON set TC gt 5s VM Adjustment of opening and closing speed 7 s 90 3 s 90 4 4 Dip Switches Description OFF ON DIP1 Drive force Normal 25 Nm Low energy 16 Nm Note to use the automation in maximum sa