Home

EDG-6528 User Manual

image

Contents

1. EDG 6528 8 Port Industrial 10 100 Mbps Ethernet Switch User Manual Copyright The documentation and the software included with this product are copy righted 2005 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this man ual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reli able However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Part No 2003652803 4th Edition Printed in Taiwan January 2006 EDG 6528 User Manual ii Product Warranty 2 years Advantech warrants to you the original purchaser that each of its prod ucts will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper instal lation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous test ing most
2. 5 Chapter 1 1 4 Packing List EDG 6528 Ethernet Switch INET CD ROM DIN rail mounting kit Panel mounting bracket 1 5 Ordering Information EDG 6528 8 port Industrial 10 100 Mbps Ethernet Switch EDG 6528L 8 port Industrial 10 100 Mbps Unmanaged Ethernet Switch e EDG 65281I 8 port Industrial 10 100 Mbps Ethernet Switch with Wide Operating Temperature 1 6 Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection device on the power supply input EDG 6528 User Manual 6 CHAPTER Installation In this chapter you will be given an overview of the EDG 6528 installation procedure Sections include LED Definitions Dimensions Mounting Network Connections Power Connections Chapter 2 Installation 2 1 LED Definitions There are network status LEDs located on the front panel of EDG 6528 each with its own specific meaning Table 2 1 EDG 6528 LED Definition LED Color Description PWR Green On Power is on Off Power is off P1 Green On Power input 1 is active EDG 6528L does Off Power input 1 is inactive not have this LED P2 Green On Power input 2 is active EDG 6528L does Off Power input 2 is inactive not have this LED FAULT Red On Power input 1 or 2 has failed EDG 6528L does Off Power input 1 and 2 are active not have this LED Link Port 1 8 Orange On Connected to network Fl
3. SRAM on chip for frame buffering Integrated address Look Up Engine supports 1K absolute MAC addresses 3 Chapter 1 1 3 Specifications Communications Standard LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Power Connectors Power Consumption Power Input Fault Output Mechanism Dimensions WxHxD Enclosure Mounting EDG 6528 User Manual IEEE 802 3 802 3u 802 3x 10 100Base TX 100 m Ethernet up to 100 Mbps 8 x RJ 45 Power Fault Link 10 100 Mbps 5 pin removable screw terminal Max 3 1 W EDG 6528 65281 2 x Unregulated 12 48 V pc EDG 6528L 1 x Unregualted 12 48 Vpc Present 56x134x114 mm Metal shell with PC side panel mounting kits included DIN 35 rail wall Protection ESD Protection Surge Protection Power Reversal Prt Certifications Safety EMC Ingress Protection Environment Operating Humidity Operating Temperature Storage Humidity Storage Temperature MTBF 4 000 V pc Ethernet 6528 65281 only 3000 V pc Power Present UL 60950 1 CAN CSA C22 2 No 60950 U S A FCC Part 15 CISPR 22 EU EN55011 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 IP30 20 95 non condensing EDG 6528 6528L 0 70 C 32 158 F EDG 6528I 40 85 C 40 185 F 0 95 non condensing EDG 6528 6528L 10 80 C 14 176 F EDG 6528I 50 95 C 58 203 F 1 260 000 hrs
4. and Ethernet Port The power line of EDG 6528 supports up to 3000 VDC surge protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 4000 V DC ESD protection for Ethernet ports not including EDG 6528L make EDG 6528 more suit able for harsh environments EDG 6528 User Manual 2 Wide Operating Temperature Range The operating temperature of the EDG 6528 is between 0 and 70 C and the EDG 65281 can operate between 40 and 85 C With such a wide range you can use the EDG 6528 in some of the harshest industrial envi ronments that exist Easy to Trouble Shoot LED indicators make troubleshooting quick and easy Each port has LEDs that display the link status power failure and port activity for immediate on site diagnosis See 2 1 1 2 Feature Summary Provides 8 x 10 100 Mbps Ethernet ports with RJ 45 connector Supports dual power inputs not including EDG 6528L Supports full half duplex flow control Supports MDI MDI X auto crossover Provides broadcast storm protection Embedded with a switch controller supports auto negotiation Embedded with the memory buffer supports store and forward trans mission Supports 12 48 VDC voltage Provides 3000 VDC surge protection for power line Provides 4000VDC ESD protection for Ethernet Ports not including EDG 6528L Provides flexible mounting DIN rail and panel mounting Supports wide range operating temperature 128 KB of
5. ashing Networking active Off Not Connected to Network 10 100 Port 1 8 Green On Link to 100M bps network Off Link to 10M bps network EDG 6528 User Manual 8 2 2 Dimensions It D Oooo ON u 1 TEH kj 000010 o J oooolor 4 D x mn D a ian o x 134 00 T g zx z 5 m a 00 vL OS EZL Wc 67 83 09 27 W C 0z ss Figure 2 1 EDG 6528 Front Panel and Dimension 9 Chapter 2 2 3 Mounting 2 3 1 Panel Mounting Attach the bracket to the EDG 6528 with four screws Place the EDG 6528 against the panel or wall and fasten it by using two screws in the bracket s holes TP me fi O Albana free aad 0 ae 0 ll L 9T T ee 0 1600 Bonne TIH lt i q E MER bi Figure 2 3 Panel Mounting EDG 6528 User Manual 10 2 3 2 DIN rail Mount
6. de Features Specifications Packing List Ordering Information Safety Precaution Chapter 1 Introduction 1 1 Features The EDG 6528 is an industrial grade Ethernet switch for fast and cost effective expansion of industrial Ethernet networks The EDG 6528 has eight 10 100 Mbps Ethernet ports to connect up to eight Ethernet devices Moreover EDG 6528 has industrial grade design that assures high reli ability and stability Therefore EDG 6528 is an excellent solution for industrial environments with Ethernet networking such as semi conduc tor factories inventory control environments assembly lines and produc tion facilities High Speed Transmission The EDG 6528 includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted Dual Power Inputs does not include EDG 6528L To reduce the risk of power failure the EDG 6528 provides dual power inputs If there is a power failure EDG 6528 will automatically switch to the secondary power input Flexible Mounting EDG 6528 is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection for Power line
7. ed within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recom mend the use of CE compliant industrial enclosure products FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product Step 2 Contact your distributor sales representative or Advantech s cus tomer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version appli cation software etc A complete description of
8. ing 1 Attach the DIN rail mounting kit to the EDG 6528 with six screws Amore SUL 2 eu 9 t a e d v e u Figure 2 5 DIN rail Mounting Il Chapter 2 2 3 3 DIN rail Dismounting Use a flat screwdriver to lift the DIN rail s attachment bracket up This will release the EDG 6528 from the Din rail Then pull the EDG 6528 down to dismount it Figure 2 6 DIN rail Dismounting EDG 6528 User Manual 12 2 4 Network Connections 2 4 1 Connection to Devices Each of the switch s twisted pair ports can be used to connect a station or another device Use a straight through twisted pair cable with RJ 45 con nectors on both ends A twisted pair cable extended from a twisted pair port is called a twisted pair segment and it can be up to 100 meters long You can connect any RJ 45 MDI X station port on the switch to any device that uses a standard network interface such as a workstation or server 2 4 2 Connection to Other Hubs or Switches EDG 6528 has 8 RJ 45 ports that support connection to 10 Mbps Ether net or 100 Mbps Fast Ethernet and half or fulld
9. of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps I Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your man ual product and any helpful information readily available 3 Ifyour product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for war ranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer iii CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operat
10. the problem The exact wording of any error messages Document Feedback To assist us in making improvements to this manual we would welcome comments and constructive criticism Please send all such in writing to support advantech com EDG 6528 User Manual iv Chapter Chapter 2 4 2 5 Contents Introduction ss F at tes iiec Feature Summary Specifications sss Packing List epe em Ordering Information sese 6 Safety Precaution eiecti eere 6 NSA LED Defritions si Table 2 1 EDG 6528 LED Definition Dimensions cete ee ERR e een Figure 2 1 EDG 6528 Front Panel and Dimension 9 Mountmg tir ire decia ei be 10 2 3 1 Panel Mounting sses mnis ene na 10 Figure 2 2 Attaching the Bracket sse 10 Figure 2 3 Panel Mounting eee 10 2 3 2 DIN rail Mounting dd 11 Figure 2 4 Attaching the DIN rail Mounting Kit 11 Figure 2 5 DIN rail Mounting eee 11 2 3 3 DIN rail Dismounting sese 12 Figure 2 6 DIN rail Dismounting ee 12 Network Connections sess 13 2 4 1 Connection to Devices 13 2 4 2 Connection to Other Hubs or Switches 13 Power Connections 14 Figure 2 7 Pin Assignment of the Power Connector 14 EDG 6528 User Manual vi CHAPTER Introduction Sections inclu
11. uplex operation EDG 6528 can be connected to other hubs or switches via a two pair straight through cable or a crossover cable The connection can be made from any ports on EDG 6528 MDIX to other Hubs or Switches either by MDI X port or the uplink MDI port EDG 6528 supports auto crossover to make it easier to setup your net work You can connect any RJ 45 MDI X station port on the switch to any device such as a switch bridge or router 13 Chapter 2 2 5 Power Connections EDG 6528 and EDG 65281 support two individual power inputs P1 P2 it will switch to another power input if one power input fails Pin Description Vs Power input 1 Range 12 48VDC Vs Power input 2 Range 12 48VDC GND Power ground Relay out EDG 6528L does not have this function You can connect to an alarm such as an indicator buzzer or other signaling equipment by EDG 6528 s relay output The r1 relay opens if power input 1 or power input 2 fails 12 48V oc Power Input 2 Figure 2 7 Pin Assignment of the Power Connector EDG 6528 User Manual 14