Home

User Manual - MPL AG Switzerland

image

Contents

1. However no matter how reliable a product there is always the remote possibility that a defect may occur The occurrence of a defect on this device may under certain conditions cause a defect to occur in adjoining and or connected equipment It is your responsibility to protect such equipment when installing this device MPL accepts no responsibility whatsoever for such defects however caused 2009 by MPL AG 3 MEH 10139 001 Rev A PIPCAN 1 5 MANUAL REVISIONS 1 5 1 RELATED PRODUCTS Manual Related To Revisions A e PIPCAN 1 2 3 4 based on Layout Rev B 1 5 2 REVISION HISTORY Manual Description Revisions 28 04 09 Initial release of this document C 2009 by MPL AG MEH 10139 001 Rev A PIPCAN 1 6 RELATED DOCUMENTATION The following documents are related to this manual For detailed Information about a specific PIPCAN feature or setting please refer to these additional manuals www mpl ch www mpl ch 1 7 ORDERING INFORMATION The table below gives you an overview of the different PIPCAN variants and its features Galvanic isolation PIPCAN 2 Freely placeable with CAN Port on an additional DB9 Connector ERI a PIPCAN 3 Product not on Stock only on request Integrated with CAN Port on a 10 Pin 0 100 double row Header Galvanic isolation PIPCAN 4 Product not on Stock only on request Fully integrated with CAN Port on an additional DB9 Connector Galvanic isolation 2009 by MPL AG 5 MEH
2. 3 PIPCAN 3 Top Layer Components 3 4 PIPCAN 4 oo 38 ales 8 S EE ZH EH EH Top Layer Components Bottom Layer Components 2009 by MPL AG 7 MEH 10139 001 Rev A PIPCAN 4 CONNECTORS 4 1 CPU Bus Connectors J1 J5 The SJA1000 on board the PIPCAN operates in Motorola Mode ALE is directly connected to J1 J5 Pin 20 CSn Multiplexing Demultiplexing of address and data is done on the PIPCAN 2 GND Supply Ground J1 PIPCAN 1 and J5 PIPCAN 3 4 J5 assembled on Bottom Layer are standard double row 2 mm pitch Sockets with following pin out 26 2 SJA1000 Data Bus 25 1 J5 PIPCAN 2 assembled on Top Layer is a standard double row 2 mm pitch header with the following pin out SJA1000 Address Bus 2009 by MPL AG 8 MEH 10139 001 Rev A ft p PIPCAN High Tech Made in Switzerland 4 2 CAN Bus Connectors The CAN Bus can be accessed via three different connectors depending the assembly variant of the PIPCAN 4 2 1 D Sub 9 J2 Pinna J2 PIPCAN 2 4 is a standard 9 Pin male D Sub connector with the following pin out s cancnod omwGmud Ps We Pe Nc U U UUU 4 2 2 2 54 mm Double Row Header J3 rine J3 PIPCAN 3 is a standard 10 Pin 2 54 mm header with 5 We 8 NC NBC A flat ribbon connection to a DB9 connector with Pin 1 9 case earth matching Pin 1 of
3. 10139 001 Rev A PIPCAN 2 SPECIFICATIONS 2 1 Electrical Supports all features of the SJA1000 controller CAN 2 0B Extended receive buffer of 64 Byte Supports 11 bit as well as 29 bit identifiers PeliCAN mode extensions Bit rate up to 1 Mbit s CAN bus optically isolated from controller 2 2 Physical Dimensions 61 x 29 2 mm side height max PIPCAN 1 2 4 12 mm PIPCAN 3 10 mm Bottom side height max PIPCAN 1 5 mm PIPCAN 3 4 12mm PIPCAN 2 3mm Single 5V supply 2 3 Environmental Storage temperature range 55 C to 125 C Operating ambient temperature range 40 C to 85 C Relative humidity 0 to 95 non condensing 2 4 Mounting options PIPCAN 1 directly pluggable to PIP internal CAN extension and Serif module connectors CAN port accessible at DB9 Serial 2 connector PIPCAN 2 pluggable to PIP internal CAN connector via a flat ribbon cable CAN port accessible at an additional DB9 connector PIPCAN 3 directly pluggable to PIP internal CAN extension connector CAN port accessible at an internal 10 pin header PIPCAN 4 directly pluggable to PIP internal CAN extension connector CAN port accessible at an additional DB9 connector above Serial 3 2009 by MPL AG 6 MEH 10139 001 Rev A PIPCAN High Tech Made in Switzerland 3 PARTS LOCATION 3 1 PIPCAN 1 EH s DERE ENT Top Layer Components 3 2 PIPCAN 2 Top Layer Components 3
4. CAN User Manual provides all the information necessary to handle and configure the PIPCAN The manual is written for technical personnel responsible for integrating the PIPCAN into their systems It is strongly recommended to read this manual and related documentation to bring the PIPCAN successfully into operation 1 2 SAFTY PRECAUTIONS AND HANDLING For personal safety and safe operation of the PIPCAN follow all safety procedures described here and in other sections of the miscellaneous manuals e Remove power from the system before installing or removing the PIPCAN to prevent the possibility of personal injury electrical shock and or damage to the product e Handle the product carefully i e dropping or mishandling the PIPCAN can cause damage to assemblies and components e Do not expose the equipment to moisture WARNING There are no user serviceable components on the PIPCAN 1 3 ELECTROSTATIC DISCHARGE ESD PROTECTION Various electrical components within the product are sensitive to static and electrostatic discharge ESD Even a small static discharge can be sufficient to destroy or degrade a component s operation With an open housing do not touch any electronic components Handle or touch only the unit chassis 1 4 EQUIPMENT SAFETY Great care is taken by MPL AG that all its products are thoroughly and rigorously tested before leaving the factory to ensure that they are fully operational and conform to specification
5. PIPCAN CAN Interface Module for MPL PIP Platforms The PIPCAN is an interface module fitting into MPL PIP computers It adds a CAN 2 0B controller which is accessible in the I O space of the CPU address range Several assembly options enable optimization of space usage within the PIP housing or even integration of the module into non PC controller hardware Features Supports CAN 2 0B e Single 5V supply Bit rates up to 1 Mbit e Does not require an additional external power supply CAN Bus with full galvanic isolation 2009 by MPL AG 1 MEH 10139 001 Rev A PIPCAN High Tech Made in Switzerland TABLE OF CONTENTS 1 INTRODUCTION 1 1 ABOUT THIS MANUAL 1 2 SAFTY PRECAUTIONS AND HANDLING 1 3 ELECTROSTATIC DISCHARGE ESD PROTECTION 1 4 EQUIPMENT SAFETY 1 5 MANUAL REVISIONS 1 5 1 RELATED PRODUCTS 1 5 2 REVISION HISTORY 1 6 RELATED DOCUMENTATION 1 7 ORDERING INFORMATION 2 SPECIFICATIONS 2 1 Electrical 2 2 Physical 2 3 Environmental 2 4 Mounting options 3 PARTS LOCATION 3 1 PIPCAN 1 3 2 PIPCAN 2 3 3 PIPCAN 3 3 4 PIPCAN 4 4 CONNECTORS 4 1 CPU Bus Connectors J1 J5 4 2 CAN Bus Connectors 4 2 1 D Sub 9 J2 4 2 2 2 54 mm Double Row Header J3 4 2 3 2 mm Double Row Socket J4 5 COPYRIGHT 6 DISCLAIMER 7 TRADEMARKS 8 SUPPORT 8 1 SERIAL NUMBER AND REVISION 8 2 CONTACT MPL AG 2009 by MPL AG 2 MEH 10139 001 Rev A PIPCAN 1 INTRODUCTION 1 1 ABOUT THIS MANUAL This manual the PIP
6. rademarks and registered trademarks of their respective holders 8 SUPPORT 8 1 SERIAL NUMBER AND REVISION For support it is needed that you know the product name the product variant and the serial number of your PIPCAN Additionally it is helpful to have the respective information of the used Processor Board and it s BIOS ready 8 2 CONTACT MPL AG In case of general information questions please feel free to contact us at our homepage www mpl ch or per email info mpl ch In case of sales information questions please send an email to sales mopl ch If you have a technical problem with a PIPCAN please first read all the related documentation and the FAQ s on our homepage carefully If you can t solve the problem on your own feel free to contact us for technical support per email at support mopl ch Our local Distributor 2009 by MPL AG 12 MEH 10139 001 Rev A
7. the DB9 results in the same pin out as d 2009 by MPL AG 9 MEH 10139 001 Rev A PIPCAN 4 2 3 2 mm Double Row Socket J4 rinse Signa pascipies J4 PIPCAN 1 is a standard 12 Pin 2 mm socket with the 3 8 CAVGND CAN Ground PIPCAN 1 plugged on a SERIF Module connector of a Ls ses mena J te Sat em D 2009 by MPL AG 10 MEH 10139 001 Rev A PIPCAN This page intentionally left blank 2009 by MPL AG 11 MEH 10139 001 Rev A PIPCAN 5 COPYRIGHT Copyright 2009 by MPL AG Elektronikunternehmen All rights are reserved Reproduction of this document in part or whole by any means is prohibited without written permission from MPL AG Elektronikunternehmen 6 DISCLAIMER MPL AG has fully tested the PIPCAN and reviewed the documentation However MPL AG makes no warranty or representation either expressed or implied with respect to this product its quality performance merchantability or fitness for a particular purpose In no event will MPL AG be liable for direct indirect special incidental or consequential damages resulting from any defect in the product or its documentation even if advised of the possibility of such damages In particular MPL AG shall have no liability for any parts connected to this product MPL AG reserves the right to make changes to any product herein to improve reliability function or design 7 TRADEMARKS Brand or product names are t