Home
SMA METEO STATION - Installation Manual
Contents
1. Grid connection RS485 bus node e g PV inverter G Sunny WebBox nimio The Meteo Station is approved exclusively for use with the supplied module temperature sensor the supplied power supply unit and any other RS485 compatible SMA devices For safety reasons it is forbidden to modify the product or install components that are not explicitly recommended or distributed by SMA The enclosed documentation is an integral part of this product e Read and adhere to the documentation Keep the documentation in a convenient place for future reference 2 2 Qualification of Skilled Persons The tasks described in this document must be performed by skilled persons only Skilled persons must have the following qualifications Training in the installation and commissioning of electrical devices Knowledge of all applicable standards and guidelines Installation Manual MeteoStation eng IAUS 122210 11 2 Safety SMA America LLC 2 3 Safety Instructions WARNING Danger to life due to electric shock Lethal voltages are present in the conductive parts inside the power supply unit e Never open the power supply unit The power supply unit is not splash proof If moisture penetrates the power supply unit you may suffer an electric shock upon contact e Only use the power supply unit in a dry indoor environment A CAUTION Risk of injury due to stumbling Incorrectly laid cables may cause in
2. Installation Manual MeteoStation eng AUS 122210 21 6 Commissioning SMA America LLC Strip the insulation of both conductors of the RS485 cable by 1 4 in 6 mm and connect these to Pin 3 and Pin 4 of the connecting terminal plate Observe the correct polarity Data to Pin 3 and Data to Pin 4 see 6 1 Terminal Assignment of the Pre harnessed Connection Cable page 21 and the technical description RS485 Cabling Plan 6 3 Connecting the Power Supply Unit to the Power Supply Requirements O O 22 The module temperature sensor must be connected see Section 5 3 Mounting the Module Temperature Sensor page 19 The power supply unit must be connected to the connecting terminal plate see Section 5 3 Mounting the Module Temperature Sensor page 19 The SMA Meteo Station must be connected to the connecting terminal plate see Section 6 2 Connecting the Meteo Station to the RS485 Communication Bus page 21 Install the power supply unit as described in the Installation Instructions for Power Supply Unit from Phoenix Contact MeteoStation eng AUS 122210 Installation Manual SMA America LLC 7 Troubleshooting 7 Troubleshooting 7 1 Errors in the SMA Meteo Station Problem Cause and corrective measures The Meteo Station is not The RS485 communication bus is not terminated detected Corrective measures e Terminate the RS485 communication bus at the connecting terminal plate for information
3. bom Measuring Device for Recording Meteorological Data at the PV Plant SMA METEO STATION Installation Manual MeteoStation engA IUS 122210 Version 1 0 Qu SMA America LLC Legal Restrictions Copyright 2012 SMA America LLC All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means be it electronic mechanical photographic magnetic or otherwise without the prior written permission of SMA America LLC Neither SMA America LLC nor SMA Solar Technology Canada Inc makes representations express or implied with respect to this documentation or any of the equipment and or software it may describe including with no limitation any implied warranties of utility merchantability or fitness for any particular purpose All such warranties are expressly disclaimed Neither SMA America LLC nor its distributors or dealers nor SMA Solar Technology Canada Inc nor its distributors or dealers shall be liable for any indirect incidental or consequential damages under any circumstances The exclusion of implied warranties may not apply in all cases under some statutes and thus the above exclusion may not apply Specifications are subject to change without notice Every attempt has been made to make this document complete accurate and up to date Readers are cautioned however that SMA America LLC and SMA Solar Technology Canada Inc reserve the right t
4. MeteoStation eng IA IUS 122210 9 Parameters Air Pressure and Humidity SMA America LLC Name Description envhmdt Relative humidity in envpress Air pressure in hPa 9 2 Adjustable Parameters The parameters are divided into display values and adjustable parameters Display values are read only adjustable parameters can also be changed Name Description Value Range Explanation Default value DevNam Device Name Text Allocation of a random designation with max 32 characters SMANetBd Bus speed 1 200 Baud SMA typical baud rate 1 200 baud DevRs Reset of the SMA A random A reset is performed Meteo Station numerical value can be set to trigger a reset of the weather station 28 MeteoStation eng AUS 122210 Installation Manual SMA America LLC 10 Technical Data 10 1 Meteo Station General Data 10 Technical Data Certified countries USA Canada Recommended installation location Outdoors Mechanical Data Diameter x height 6 in x 10 Y in 150 mm x 268 mm Weight with bracket without connection cable 3 Ibs 1 3 kg Mounting type Pole fixtures 2 in to 3 in 60 mm to 76 mm Voltage Supply Voltage supply Power supply unit Supply voltage 24 V DC 20 Typical current input 135 mA Maximum current consumption 500 mA Typical power consumption 2W Ambient Conditions Deg
5. during operation CE marking The information on the type label is intended to help you use the SMA Meteo Station safely and will be needed when you contact the SMA Service Line The type label must be permanently attached to the SMA Meteo Station Installation Manual MeteoStation eng 1A 1US122210 15 4 Product Description SMA America LLC 4 2 Power Supply Unit The power supply unit is a grid powered voltage converter made by Phoenix Contact The power supply unit fulfills the following tasks e Voltage supply to the Meteo Station It is not permitted to use the power supply unit for any other purpose Any other use can result in personal injury or property damage You will find precise information on the power supply unit in the attached installation instructions from Phoenix Contact Only install the power supply unit as described in the installation instructions 16 MeteoStation eng AUS 122210 Installation Manual SMA America LLC 5 Mounting 5 Mounting 5 1 Mounting the Connecting Terminal Plate and the Power Supply Unit Requirements O 0000 Adhere to the requirements in the attached installation instructions from Phoenix Contact The mounting location must be indoors A maximum cable route of 33 ft 10 m to the PV modules must be taken into account A maximum RS485 communication bus length of 328 ft 100 m must be taken into account The power supply unit must be protected from dust moisture and a
6. of Skilled Persons page 11 A DANGER Explanation Indicates a hazardous situation which if not avoided will result in death or serious injury A WARNING Indicates a hazardous situation which if not avoided can result in death or serious injury A CAUTION Indicates a hazardous situation which if not avoided can result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates a requirement for meeting a specific goal TR Desired result A problem that could occur MeteoSta tion eng A IUS 122210 Installation Manual SMA America LLC 1 Information on this Document Typographies Typography Use Example light Display messages on the The value can be read in inverter the Energy field Elements in a software user interface Connections bold e Elements to be selected e Enter 10 in the Minutes field gt Several elements thatare Select Settings gt Date to be selected Button Key e Button or key to be Select Next selected or pressed Nomenclature Complete designation SMA America Production LLC and SMA Solar Technology Canada Inc Designation in this document SMA SMA Meteo Station Meteo Station Abbreviations Abbreviatio
7. 22210 23 7 Troubleshooting SMA America LLC Problem The Meteo Station reports error value 3 ErrSensSollrr or error value 8 WrnSensSollrr or unrealistic values are displayed for the pyranometer Cause and corrective measures The glass dome of the pyranometer is damaged or soiled Corrective measures e Clean the glass dome of the pyranometer e Contact the SMA Service Line see Section 11 Contact page 32 The Meteo Station reports error value 4 ErrCalibData or error value 10 WrnMtSensSollrr The calibration data of the pyranometer is not valid Corrective measures Register the Meteo Station at SMA for calibration see Section 11 Contact page 32 The Meteo Station resports an error value not listed here This can have various causes Corrective measures e Contact the SMA Service Line see Section 11 Contact page 32 7 2 Errors in the Power Supply Unit Problem The DC OK LED on the power supply unit is not lit Cause and corrective measures The power supply unit has no power Corrective measures e Check whether line voltage is available 24 MeteoStation eng A IUS 122210 Installation Manual SMA America LLC 8 Decommissioning 8 Decommissioning 8 1 Disassembling the Meteo Station Additional tools required not included in the scope of delivery L1 Metric wrench AF13 I Remove the power supply unit from the power suppl
8. afe installation and operation of the product you must carefully read and follow all instructions cautions and warnings in this document Warnings in this document A warning describes a hazard to equipment or personnel It calls attention to a procedure or practice which if not correctly performed or adhered to could result in damage to or destruction of part or all of the SMA equipment and or other equipment connected to the SMA equipment or personal injury Symbol Description A DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury A WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury A CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury AR MeteoStation eng A4US 122210 Installation Manual SMA America LLC Important Safety Instructions General Warnings WARNING General Warnings All electrical installations must be done in accordance with the local safety codes and the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 This document does not and is not intended to replace any local state provincial federal or national laws regulation or codes applicable to the installation and use of the product inc
9. al plate to the mounting location of the Meteo Station 2 Remove the yellow cap from the device plug Press the connection cable into the notch to hold it in place on the Meteo Station and move the female connector towards the device plug i Connect the cable taking the position markings into account There is a keyway on the cable socket and a key on the device plug e When plugging the female connector make sure that the keyway on the cable socket and the key on the device plug are properly aligned Fasten the screw ring of the female connector This holds the connection cable in place Unfasten both nuts on the retaining bracket of the Meteo Station Push the Meteo Station over the top end of the pole NOTICE You may damage the Meteo Station by fastening the nuts on the retaining bracket too tight o NM Oo t e Tighten both nuts until the springs on the retaining bracket begin to compress e Then fasten each nut with three turns 5 3 Mounting the Module Temperature Sensor Requirements Ll The module temperature sensor must be installed on a PV module that is not shaded at any time DI A maximum cable route of 33 ft 10 m to the connecting terminal plate must be taken into account A CAUTION Risk of burn injuries if you touch the PV modules In strong direct solar irradiation PV modules can heat up to temperatures as high as 176 F 80 C e Mount the module temperature sensor at a time at which no dire
10. ct sunlight is shining on the PV modules Installation Manual MeteoStation eng1A1US122210 19 5 Mounting SMA America LLC l i Cleaning the adhesive surface The surface must be free of dirt and moisture otherwise the module temperature sensor is likely to fall off after sticking Use the cleaning cloth to wipe the surface of the PV module at the spot where the sensor is to be affixed The spot must be located on the underside of the PV module 2 Remove the masking paper from the pre mounted double sided adhesive tape on the module temperature sensor 3 NOTICE Damage to the PV module if you press the sensor on too hard It is possible to damage the PV module by pressing the module temperature sensor on too hard e Observe the notes on mechanical strength in the PV module manual Stick the module temperature sensor to the clean adhesive surface on the PV module pressing it on as firmly as the mechanical strength allows 4 Lay the module temperature sensor cable to the VE mounting location of the connecting terminal plate Al P lt 5 Connect one insulated conductor of the module temperature sensor to Pin 5 and the other to Pin 6 of the connecting terminal plate This can be done in any order 20 MeteoStation eng A 1US 122210 Installation Manual SMA America LLC 6 Commissioning 6 Commissioning 6 1 Terminal Assignment of the Pre harnessed Connect
11. ggressive substances Mount the power supply unit and connect it to the connecting terminal plate see Installation Instructions for Power Supply Unit from Phoenix Contact Mount the connecting terminal plate on the top hat rail 5 2 Mounting the Meteo Station Requirements O O O The ambient temperature must be between 40 F to 140 F 40 C to 60 C The diameter of the pole on which the Meteo Station is mounted must be between 2 in and 3 in 60 mm to 76 mm The pole must be stabilized by an appropriate wall or floor fixture The mounting location must be shadow free and with an unimpeded panoramic view at the height of the pyranometer Remember that the maximum cable length to the connecting terminal plate is 33 ft 10 m The Meteo Station must be protected from aggressive or toxic substances Installation Manual MeteoStation eng AUS 122210 17 5 Mounting SMA America LLC Figure 4 Parts of the Meteo Station which are relevant for mounting Position Description Retaining bracket Device plug Spring Nut and washer Notch to fix the connection cable Connection cable with female connector and screw ring Pole Qimimizouw 18 MeteoStation eng A 1US 122210 Installation Manual SMA America LLC 5 Mounting Additional tools required not included in the scope of delivery L1 Metric wrench AF13 1 Connection cable from the connecting termin
12. ion Cable Pin no Color Signal designation white Ground supply voltage GND 2 brown Positive supply voltage 12 V 3 green RS485 D 4 yellow RS485 D 5 gray Module temperature sensor 6 pink Module temperature sensor Insulated conductors 1 to 4 are already connected to the connecting terminal plate upon delivery The terminating resistor is connected between insulated conductors 3 and 4 Pins 5 and 6 must be connected to the two insulated conductors of the module temperature sensor in any order 6 2 Connecting the Meteo Station to the RS485 Communication Bus Requirement O O 5 The RS485 cable must be connected to the RS485 bus node see manual of the RS485 bus node Note the pre harnessed termination of the Meteo Station by means of the terminator for details of the layout of the RS485 communication bus see the technical description RS485 Cabling Plan Strip 8 in 200 mm of the cable sheath off the RS485 cable Shorten the cable shield to U in 15 mm Trim the unneeded insulated conductors back as far as the cable sheath for terminal assignment and wiring see the technical description RS485 Cabling Plan Pull back the cable shield and cover with conductive adhesive foil Connect the RS485 cable to the shield connection terminal of the connection cable making sure that the conductive adhesive foil has electrical contact to the shield connection terminal
13. is a device for measuring power related meteorological data at the PV plant location and for transmitting this data to the Sunny WebBox via the Power Injector The Meteo Station fulfills the following tasks Measurement of global radiation Measurement of PV cell temperature Measurement of absolute air pressure Measurement of air temperature and humidity Transmission of this meteorological data to the Sunny WebBox Figure 3 Design of the Meteo Station Position Description A Pyranometer B Air pressure sensor in the device Sensors for measuring air temperature and humidity 14 MeteoStation eng A 1US 122210 Installation Manua SMA America LLC A Product Description Position Description D Fan E Device plug F Connection cable with female connector G Retaining bracket with springs and self locking nuts H Notch to fix the connection cable Pre harnessed connection cable Position Description A Shield connection terminal B Connecting terminal plate with rail adapter and terminator C Device plug Type Label You can identify the Meteo Station by means of the type label The type label is located on the underside of the Meteo Station where the nuts and springs are also attached You can read out the following data from the type label Serial number and hardware version e Power consumption operating voltage Permissible ambient temperatures
14. juries due to tripping hazard e Lay the cables in such way that no one can step on or trip over them NOTICE Damage to the SMA Meteo Station by lightning strike The Meteo Station is not equipped with lightning protection A lightning strike could damage or destroy the Meteo Station e The Meteo Station must be integrated in the existing lightning protection equipment Damage to the power supply unit due to moisture penetration The power supply unit is not splash proof e Only use the power supply unit in a dry indoor environment 12 MeteoStation eng AUS 122210 Installation Manual SMA America LLC 3 Scope of Delivery 3 Scope of Delivery Check the delivery for completeness and any visible external damage Contact your specialty retailer if the delivery is incomplete or you find any damage A B C D E F Figure 2 Components included in the scope of delivery Position Quantity Description A Meteo Station B 1 Pre harnessed connection cable C 1 Module temperature sensor with cleaning cloth D 1 CD with installation manual quick reference guide for commissioning Technical Information R 485 Cabling Plan E 1 Power supply unit Phoenix Contact F 3 Conductive adhesive foil 2 Shield connection terminal Installation Manual MeteoStation eng AUS 122210 13 4 Product Description SMA America LLC 4 Product Description 4 1 Meteo Station The Meteo Station
15. l 61 2 9669 2889 Fax 61 2 9669 2887 Service SMA Australia com au www SMA Australia com au 32 MeteoStation eng AUS 122210 Installation Manual SMA Solar Technology SMA America LLC www SMA America com
16. luding without limitation applicable electrical safety codes All installations must conform with the laws regulations codes and standards applicable in the jurisdiction of installation SMA assumes no responsibility for the compliance or non compliance with such laws or codes in connection with the installation of the product For all repair and maintenance always return the unit to an authorized SMA Service Center Before installing or using the product read all of the instructions cautions and warnings in this document Wiring of the product must be made by qualified personnel only Installation Manual MeteoStation eng IAUS 122210 5 Table of Contents SMA America LLC Table of Contents 1 2 2 1 2 2 2 3 3 4 4 1 4 2 5 5 1 5 2 5 3 6 6 1 6 2 6 3 7 7 1 7 2 8 8 1 8 2 Information on this Document 9 Safety siena VUA dde Re uL Ra iA 11 Iniended Hs6 score NP oSv e a antes iba pati nds 11 Qualification of Skilled Persons LL 12 Safety Instructions oaaao eal iW edhe ad ea tae 13 Scope of Delivery 2 cece eee cece eee eee 14 Product Description 4 2 eee en n 15 Meteo Slaton 224 rile tina 15 Power Supply Unit cce tet esit e ePi usn 17 Mounting ssena a a 18 Mounting the Connecting Terminal Plate and the Power Supply Unit S c se kate eod aee ve Rd 18 Mounting the Meteo Station arri 18 Mounting the Module Temperature Sensor 20 Commi
17. m Resolution lt 1 W m Measuring interval 1 minute Certification according to ISO9060 second class 30 MeteoStation eng A IUS 122210 Installation Manual SMA America LLC Module Temperature Sensor 10 Technical Data Measuring procedure NTC Cable length 33 ft 10 m Measuring range 4 F to 176 F 20 C to 80 C Measurement accuracy lt 1 8 F lt 1 0 C Measuring interval minute Installation Manual MeteoStation engIA IUS 122210 31 11 Contact SMA America LLC 11 Contact If you have technical problems concerning our products contact the SMA Service Line We need the following data in order to provide you with the necessary assistance e Serial number and firmware version of the SMA Meteo Station e Serial number and firmware version of the Sunny WebBox SMA Solar Technology America LLC 6020 West Oaks Blvd Ste 300 Rocklin CA 95765 Tel 1 916 625 0870 Tel 1 877 MY SMA TECH Tel 1 877 697 6283 Toll free available for USA Canada and Puerto Rico Fax 1 916 625 0871 Service SMA America com www SMA America com SMA Solar Technology Canada Inc 2425 Matheson Blvd E 8th Floor Mississauga ON LAW 5K5 Canada Tel 1 877 506 1756 Toll free available for Canada Service SMA Canada ca www SMA Canada ca SMA Technology Australia Pty Ltd Suite 106 30 40 Harcourt Parade Rosebery NSW 2018 Te
18. ns AF Designation Width Across Flats Explanation The distance between two parallel flat surfaces flats of a screw head MEMS Micro Electro Mechanical System MSL Mean Sea Level NTC Negative Temperature Coefficient Electric resistor with a negative Thermistors temperature coefficient PV Photovoltaics Installation Manual MeteoStation engIA IUS 122210 9 2 Safety SMA America LLC 2 Safety 2 1 Intended Use SMA Meteo Station The Meteo Station is a device for measuring power related meteorological data at the PV plant location and for transmitting this data to the Sunny WebBox via RS485 communication bus The Meteo Station fulfills the following tasks Measurement of global radiation PV cell temperature absolute air pressure air temperature and humidity and transmission of this data to the Sunny WebBox Any other use can result in personal injury or property damage The SMA Meteo Station s degree of protection is NEMA 3 and is suitable for outdoor and indoor use within a temperature range of 40 F to 140 F 40 C to 60 C Figure 1 Example Diagram of a PV plant with Meteo Station and Sunny WebBox Position Description A PV module with module temperature sensor 10 MeteoStation eng A 1US 122210 Installation Manua SMA America LLC 2 Safety Position Description Meteo Station Connecting terminal plate Power supply unit
19. o make changes without notice and shall not be responsible for any damages including indirect incidental or consequential damages caused by reliance on the material presented including but not limited to omissions typographical errors arithmetical errors or listing errors in the content material All trademarks are recognized even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA America LLC and SMA Solar Technology Canada Inc is under license SMA America LLC 3801 N Havana Street Denver CO 80239 U S A SMA Solar Technology Canada Inc 2425 Matheson Blvd E 8th Floor Mississauga ON LAW 5K5 Canada Installation Manual MeteoStation eng AUS 122210 3 Important Safety Instructions SMA America LLC IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for the following products e SMA Meteo Station e Module temperature sensor e Power supply unit This manual must be followed during installation and maintenance The product is designed and tested according to international safety requirements but as with all electrical and electronic equipment certain precautions must be observed when installing and or operating the product To reduce the risk of personal injury and to ensure the s
20. on termination see the technical description R 485 Cabling Plan The Meteo Station cannot be The RS485 communication bus is not terminated queried or does not respond to queries Corrective measures e Terminate the RS485 communication bus at the connecting terminal plate for information on termination see the technical description R 485 Cabling Plan Supply voltage is interrupted Corrective measures e Ensure that the Meteo Station is supplied with voltage Cable shields are not properly positioned Corrective measures e Ensure that the cable shields are properly positioned and connected to the shield connection terminal The Meteo Station reports error The sensor for measuring ambient temperature is faulty value 1 ErrSensAmbTemp or error value 6 WrnSensAmbTemp Corrective measures e Contact the SMA Service Line see Section 11 Contact page 32 The Meteo Station reports error The module temperature sensor has no contact with the value 2 ErrSensModTemp or PV module error value 7 WrnSensModTemp or unrealistic values are displayed for the module temperature sensor The module temperature sensor is defective Corrective measures Ensure that there is contact between the module temperature sensor and the PV module Corrective measures e Contact the SMA Service Line see Section 11 Contact page 32 Installation Manual MeteoStation eng IAUS 1
21. ree of protection NEMA 3 Ambient temperature 40 F to 140 F 40 C to 60 C Relative humidity 5 to 95 Max permissible height above MSL 9 840 ft 3 000 m Communication Communication RS485 Installation Manual MeteoStation eng IA IUS 122210 29 10 Technical Data Air Temperature Measurement SMA America LLC Measuring procedure NTC Measuring range 58 F to 140 F 50 C to 60 C Resolution 0 18 F at 4 F to 122 F otherwise 0 36 F 0 1 C at 20 C to 50 C otherwise 0 2 C Accuracy of sensor 0 36 F at 4 F to 122 F otherwise 0 9 F 0 2 C at 20 C to 50 C otherwise 0 5 C Measuring interval minute Units AC TE Measurement of Humidity Measuring procedure Capacitive Measuring range O to 10076 relative humidity Resolution 0 1 relative humidity Accuracy 2 relative humidity Measuring interval minute Units relative humidity Measurement of Air Pressure Measuring procedure MEMS sensor capacitive Measuring range 4 35 Psi to 17 4 Psi 300 hPa to 1 200 hPa Resolution 0 001 Psi 0 1 hPa Accuracy 0 02 Psi 1 5 hPa Measuring interval minute Pyranometer Sensor Kipp amp Zonen CMP 3 Measuring procedure Thermopile pyranometer Measuring range 0 0 W m to 1 400 0 W
22. ssioning 493 n bac ana 22 Terminal Assignment of the Pre harnessed Connection Cable 22 Connecting the Meteo Station to the R5485 Communication BUS sew De a pet ido dna 22 Connecting the Power Supply Unit to the Power Supply 23 Troubleshooting i ro e heh nt RR Rn 24 Errors in the SMA Meteo Station 24 Errors in the Power Supply Unit cree rrr ots 25 Decommissioning 4 36 eux iaia 26 Disassembling the Meteo Station 26 Disassembling the Module Temperature Sensor 26 MeteoStation eng IA US 122210 Installation Manual SMA America LLC 8 3 8 4 8 5 9 9 9 2 10 10 1 11 Disassembling the Connecting Terminal Plate and Power Supply Unit odes eon TUER iata Packing the Meteo Station for Shipping Disposing of the Meteo Station LL Parameters oes e da XOU aaa Display ValUGS 4 cvxe ere tal sanario ode y eat Adjustable Parameters aria a Technical Data vie pud er y OR RR RR CER a eg Meteo Station i Contact ij nos veli ub ERR WR VR TE TE Ea Installation Manual MeteoStation eng IAUS 122210 Table of Contents 1 Information on this D ocument SMA America LLC 1 Information on this Document Validity This manual is valid for the SMA Meteo Station from firmware version 2 80 01 Target Group This document is in set forth in this doc tended for skilled persons Only skilled persons are allowed to perform the tasks ument see Section 2 2 Qualification
23. ta page 29 8 5 Disposing of the Meteo Station Dispose of the device according to the disposal regulations for electronic waste that apply at the installation site or Send the device to SMA at your own expense for contact details see Section 11 Contact page 32 Label the packaging ZUR ENTSORGUNG FOR DISPOSAL 26 MeteoStation eng A 1US 122210 Installation Manual SMA America LLC 9 Parameter 9 Parameters S 9 1 Display Values The parameters are divided into display values and adjustable parameters Display values are read only adjustable parameters can also be changed Meteo Station Name Description SN Serial number of the SMA Meteo Station FwVer Firmware version of the SMA Meteo Station HWVer Hardware version of the SMA Meteo Station OpTm Operating time of the SMA Meteo Station since commissioning in hours Mode Display of operating states 0 normal operation 1 initialization 2 warning 3 error Internal Global Rad iation Sensor Name IntSollrr Description Global radiation in W m Module Temperature Sensor Name Description TmpMdul C Cell temperature in C TmpMdul K Cell temperature in K TmpMdul F Cell temperature in F Ambient Temperature Name Description TmpAmb C Ambient temperature in C TmpAmb K Ambient temperature in K TmpAmb F Ambient temperature in F Installation Manual
24. y see Installation Instructions for Power Supply Unit from Phoenix Contact Unfasten both nuts on the retaining bracket of the Meteo Station Slide the SMA Meteo Station upwards and off the end of the pole Unscrew the screw ring and pull the connection cable out of the Meteo Station 8 2 Disassembling the Module Temperature Sensor 1 Disconnect the two conductors of the module temperature sensor from the connecting terminal plate NOTICE Damage to the PV module by removing the module temperature sensor Do not remove attached sensors from PV modules as otherwise the modules may be damaged The module temperature sensor cannot be re used Cut the sensor cable off flush with the module temperature sensor 8 3 Disassembling the Connecting Terminal Plate and 2 Power Supply Unit Lever the connecting terminal plate from the bottom of the top hat rail forward and out To do this apply F downward pressure After releasing the bottom of the connecting terminal plate pull it upwards off the top hat rail Remove the power supply unit from the top hat rail see Installation Instructions for Power Supply Unit from Phoenix Contact Installation Manual MeteoStation eng 1A 1US122210 25 8 Decommissioning SMA America LLC 8 4 Packing the Meteo Station for Shipping e Pack the device For this purpose use the original packaging or packaging suitable for the weight and size of the device see Section 10 Technical Da
Download Pdf Manuals
Related Search
Related Contents
Catalogue principaux produits Telemecanique SC101 Keyboard manual Télécharger la fiche technique du Onkyo TX-NR509 4 e dimanche du temps pascal Vogel's PFW 6852 Display wall mount, 136 kg APC Isolation and Step PDF版カタログダウンロード:FL無線機 Rust-Oleum Specialty 1955830 Use and Care Manual Copyright © All rights reserved.