DAQ Browser: FSH (Facility Status History): user's manual
Contents
1. 4 12 11 03 10 47 AM DAQ Browser FSH Facility Status History user s manual http www desy de pcastro example_progs applica FacilityStat Getting started PITZ DES Y ZEUTHEN in a Solaris workstation ex corvus by typing start_fsh this will execute the script bin zsh cd net corvus doocs dag fsh export ROOTSYS cern root v3 05 05 export LD_LIBRARY_PATH net corvus doocs dagq fsh cern root v3 05 05 lib net corvus doocs sol net corvus doocs dagq fsh PlotFSH Values displayed e On the left side of the plot values of the status at the position of the cursor vertical black line e On the left side of time scale time and date at the position of the cursor vertical black line dipole magnet ori 16 00 07 O3fO0ct0s 12 00 06 O4 Oct03 20 0 hours ZA On the top of the plot name value begin end and duration of the status under the cursor Changing the horizontal time scale The widgets for changing the time scale are just below the plot Time scale selection E months resetfupdate plot now scale ending Z now or select time hourmin 9 44 and day monthvyear 4 12 2003 4 e To zoom in the time scale position the cursor inside the plot press the right mouse key drag over and release the key If the cursor is outside left or right of the plot at the moment of the key release the scale will expand to the minimum or maximum range value To zoom out the scale click the
2. DAQ Browser FSH Facility Status History user s manual http www desy de pcastro example_progs applica FacilityStat DAQ browser FACILITY STATUS HISTORY FSH Index Goal Version Getting started Values shown Time scale Select time period Select status Change width of the plot Save recall plot configuration Exit the program To do outlook Example of display for PITZ PIT status history File View Help Config file no configuration file VV OLUES dipole magnet on 16 00 07 O3 Oct03 12 00 06 O4fOct0s 20 0 hours oe oa a magne interlock ae ee personal interlock O1 2 50 21 Sepi03 28 Sepl3 2 DctI03 HOt 26 0ct03 02 Nowitg O0S Nowil3 Suni Sun Sun Sun O4 Octo Time scale selection E months reset update plot now scale ending IW now or select time hourmin 9 44 and day month year 4 12 2003 4 selected time enna begin 13 20 29 92003 end aaa f 11710 2003 ditiis days start retrieve of data Goal of the program This program aims to visualize a history of the status of the accelerator as recorded by the status servers With this program the user selects a time period for retrieving data from DAQ Version of the program Source files in CVS Last release version 1 02 from 4th Dec 2003 13 classes 3907 lines 110 kB of code about half of it in THistWin cpp Updated on 10th Dec 2003 Works with ROOT 3 05 07 or later version 1 of
3. and selecting Open config file At the start the program searches in the current directory for a file with name FSH standard config If it does not exist the program starts with a default hard coded configuration How to exit the program Click on File menu and select Exit Outlook List of to do s Of course Connect the button start retrieve of data to the Archive filter program being developed In the status menu give the possibility to order the status selected Add a plot to include scalars like beam energy repetition frequency RF pulse length bunch charge etc Read status data from a history status server to be written How to change time and date entries using up down arrow Keys 3 44 1110 2003 The time and date entries have two small buttons on the right to increase and decrease the numerical value in the field The same effect have the up and down cursor keys The step size is the minimum 1 e for time is one minute and for date is one day A larger step size can be selected pushing the keys shift and control see table below change in time date minute day pressing shift hour month pressing control 10 hours year For any problems comments bug report etc please send me an e mail 12 11 03 10 47 AM
4. button reset update plot now e A double slider to select the time range of the visible plot Press on the left right side of the slider and drag to change the visible time range Press on the center to shift the scale scale ending W now hours time period 4 34 eO 10 2005 to select the full range of the plot The options are 8 hours 1 day 3 days l week l month 4 months etc e A chech button with label now to select the end of the time scale If the button is checked then the end of the time scale is the current time now If the button is NOT checked then the end of the time scale is given by the time and data on the right side of the button e Two entries time and date of the end of the scale if the button now is checked then current time and date are shown and can not be changed To change then click on the button now Then the entries become white and can be changed by typing a new value or using up down arrow keys To validate the change press enter or press the button reset update plot now Select a time range for retrieving DAQ data To select a period of time with the cursor 2 of 4 12 11 03 10 47 AM DAQ Browser FSH Facility Status History user s manual http www desy de pcastro example_progs applica FacilityStat 1 To mark the begining Place the cursor inside the plot and push the key b on the keyboard A violet vertica
5. l line shows up and the corresponding the time and date appear at the bottom of the window in the box selected time period 2 To mark the end Place the cursor inside the plot on the right side of the line beginning and push the key e A violet vertical line shows up and the corresponding the time and date appear at the bottom of the window Note if the cursor is on the left side of the line beginning the line beginning moves to a place between the left side and the end line selected time period begin 13 20 esvveooa end g44 SY 11710 2003 dit f11 5 days start retrieve of data A period of time can be also selected by typing the times and dates at the entries inside the box selected time period The values are actualized in the plot by pressing enter See how to change time amp date entries using up down arrow keys How to select the list of status Click on File menu top right Open config file save config file show present config Ion pane Feedforward model valye6 selected main magnet l Far cup Feedforward mode bucking magnet D screen PP dipole magnet dipole magnet T screen ANA personal interlock quadi3 magnet TO getterpump 5 quad magnet T photomultiplier steerer magnet infrared sensor steererB magnet D e detector steerer magnet LUWG photodiode steerer magnet D diff temp in out steererz magnet temp inner conducter PUMP23 of WCS temp wa
6. ve guide PUMP24 of WCS temp window EH21 of WCS P waterflow SW 202 of WCS f cup piloterm SWH222 of WCS temp window PT100 3 valved M personal interlock valved F laser shutter valved accelerator work mode valved CLOSE this window The status shown in the plot are marked with a check sign The list of selected status is shown in the box on the right side Click on the status names to select or de select status A maximum of 11 status can be selected How to change the width of the plot Click on View menu top right and select to view 60 or 100 Note resizing the main window does not change the size of the plot 3 of 4 12 11 03 10 47 AM DAQ Browser FSH Facility Status History user s manual http www desy de pcastro example_progs applica FacilityStat 4 of 4 How to save recall the configuration of the plot The current configuration of the plot can be shown by clicking on File menu and selecting Show present config It can be saved onto a file by clicking on File menu and selecting Save config file It is recommended to add the extension config to the name of the file An example of a config file TimeScale 1 month EndOfScale now TimeSelBegin 2003 11 08 10 38 00 TimeSelEnd 2003 11 20 14 47 00 StatusList net corvus doocs server fsh prop_file_new Selected Feedforward mode dipole magnet personal interlock A saved configuration can be recalled by clicking on File menu
Download Pdf Manuals
Related Search
Related Contents
Hikvision DVR manual Acronis® Backup & Recovery ™ 10 Advanced Workstation TracPhone V7-IP User's Guide (with ICM) JABRA STEALTH Modelo CA12CD/A Cognac Mag décembre 2012 ServerView Integration 2.3 in HP OpenView NNM Philips SWA3714 User's Manual ビデュリオン 皮下注用2mg 1. Brochure alarmes sans fil Espace Copyright © All rights reserved.