Installation Instructions and Operating Instructions LIK 8TE

image

Contents

1. dM sne Bue sny JneyoAsBunzioH oen ueBuniejogo9 3 6 ueuu s a yz aH jne qeyesuepuoy 00 00 e ve SLX8N epuiweBueuu sjulof juos xnep 591 lqnop ajddiu 005 ep slidwo nea p 591 SNOL Ajddns jo edoos eu ajddiu ejqnop pue 009 JOU suono uuoo IN sap ag jeddiu pun uonejuos 006 essnjuosuejesse 5 Anhang Appendix Annexes ep 9199 epis Buneiedo ejyesueipeg uonesuepuoo nee SUBS esou JO 6 yone yos 14211 suonoeuuoo 13M essniyosue 0750 A 1 2 1 2 Einbauma e Installation Dimensions Cotes de montage 500 20 0 N H H d d d d d 4 d E d d d d 8 LE 650 Luftrichtung Direction of air flow Sens d coulement air Bedienseite Operating side C t de commande 750 www dimplex de 500 20 1343210 ooooo 1 handels blicher Bauschaum bauseits Standard polyurethane foam to be provided by the cust
2. 9 O Absperrventil berstromventil Sicherheitsventilkombination Umw lzpumpe Ausdehnungsgef Raumtemperaturgesteuertes Ventil Absperrventil mit R ckschlagventil Absperrventil mit Entw sserung W rmeverbraucher Temperaturf hler Flexibler Anschlussschlauch W rmepumpe Pufferspeicher W rmepumpenregler Elektroverteilung Warmwasserspeicher Kondensatablauf berdruck Heizwasser Zusatzheizung Heizungsumw lzpumpe Warmwasserumw lzpumpe W rmepumpenregler Au entemperaturf hler R cklauff hler Warmwasserf hler Elektroverteilung Kaltwasser Mischer AUF Warmwasser Shutoff valve Overflow valve Safety valve combination Circulating pump Expansion vessel Room temperature controlled valve Shutoff valve with check valve Shutoff valve with drainage Heat consumer Temperature sensor Flexible connection hose Heat pump Buffer tank Heat pump controller Electrical distribution system Hot water cylinder Condensate outflow Overpressure of the heating water Supplementary heating Heat circulating pump Hot water circulating pump Heat pump controller External temperature sensor Return flow sensor Hot water sensor Electrical distribution system Cold water Mixer OPEN Domestic hot water Robinet d arr t Vanne de trop plein Groupe de valves de s curit Circulateur Vase d expansion Valve command e par temp rature Robinet d arr t avec clapet anti retour Robi
3. www dimplex de gt 5 5 D 5 gt 5 5 5 x gt 5 5 x 3 4 3 4 Legende Legend L gende 1 2 4 B3 B4 E3 E10 F2 F3 F4 F5 F7 F23 H5 Ji J2 J7 J8 J10 J11 J12 J18 X1 X2 X3 X4 X5 Y1 EVU SPR MA MZ Drahtbr cke einlegen wenn kein EVU Sperr sch tz ben tigt wird Eingang offen EVU Sperre W rmepumpe aus Drahtbr cke bei Nutzung des 2ten Sperreinganges entfernen Eingang offen W rmepumpe aus Drahtbr cke St rung Verdichter M1 Thermostat Warmwasser Thermostat Schwimmbadwasser Pressostat Abtauende 2 W rmeerzeuger Elektroheizung Funktion ist ber Regler w hlbar Sicherung f r N1 Relaisausg nge an J12 und J13 4 0 ATr Sicherung f r N1 Relaisausg nge an J15 bis J18 4 0 ATr Pressostat Hochdruck Pressostat Niederdruck Hei gasthermostat Wicklungsschutz Ventilator Leuchte St rfernanzeige Relaisbaugruppe Stromversorgung N1 24V AC Niederspannungsein ausg nge Signalein ausg nge 230V AC Ohne Funktion Steckdose f r Bedienfeld Ohne Funktion Relaisausg nge zur Ansteuerung der Systemkom ponenten Sch tz Verdichter Relais Ventilator Elektron Relais f St rfernanzeige Relaisbau gruppe Elektron Relais f Schwimmbadwasserumwalz pumpe Relaisbaugruppe Sch tz 2 W rmeerzeuger EVU Sperrsch tz SPR Hilfsrelais Verdichter Ventilator Heizungsumw lzpumpe
4. Installation een E 5 821 General ro veta te rev seed 5 6 2 Ain re AE 5 6 3 Heating System Connection sisi E 6 64 Electrical Connection E 6 o lil ee S Tr ee uta ee E 7 721 General nformMatOnive eee ee en es epe annee ue E 7 7 2 Preparation NEE E 7 1 3 Star u Mote nn deae E 7 8 Malntenance Cleaning u u tiene rete rcc ela aia enn E 8 Ball banniere A ne ee E 8 8 2 Cleaning the Heating System iii E 8 8 3 Cleaning the Air System ee tes Sta sel Ati E 8 9 Faults 8 10 Decommissioning Disposal UU ne J E 8 Tt Device Intormatiori EE E 9 Anhang Appendix 0 719 0 4 808 808 1 08 00002227 A I E 1 1 Please Read Immediately 1 1 Important Information A ATTENTION The device is not suitable for operation with a frequency converter A ATTENTION When transporting th
5. 2 m3 h Free pressure heating circulating pump max stage Pa Air flow rate with an external static pressure differential ofm h Pa Refrigerant total filling weight type kg Output of electric heating element second heat generator kW Dimensions connections and weight Device dimensions HxWxLcm Device connections to heating system Inch Air duct inlet and outlet min internal dimensions LxWcm Weight of the transportable unit s incl packing kg Buffer tank volume Buffer tank pressure rating bar Electrical Connection Nominal voltage fuse protection V A Nominal power consumption 1 2 35 Starting current with soft starter A Nominal current A2 W35 cos o A Complies with the European safety regulations Additional model features Defrosting Type of defrosting Defrosting tray included Heating water in device protected against freezing 1 Performance levels Controller internal external LIK 8TE Compact IP 20 Indoors Up to 58 above 18 20 to 35 10 0 5 0 5 8 2 7 5 5 2 6 5 4 2 1 7 5 3 3 7 4 3 2 9 3 3 9 9 2 3 8 8 8 3 2 9 8 4 1 9 7 4 0 53 60 48 0 0 8 2700 1 6 11900 45000 0 2500 20 R404A 2 0 2 0 190 x 75 x 68 G 1 external 44 x 44 245 50 6 400 16 2 27 2 33 19 5 41 08 4 2 0 8 3 Automatic Reverse cycle Yes heated Yes 1 Internal This data indicates the size and capacity of the system For an analysis the economic and energ
6. Hauptkreis Heizungsumw lzpumpe 2 Heizkreis Zusatzumw lzpumpe Warmwasserumw lzpumpe Schwimmbadwasserumw lzpumpe Mischer Hauptkreis Mischer 2 Heizkreis W rmepumpenregler Sanftanlaufsteuerung Verdichter Relaisbaugruppe Bedienteil Au entemperaturf hler R cklauff hler Heizung Warmwasserf hler alternativ zum Warmwasser thermostat F hler f r den 2ten Heizkreislauf Vorlauff hler Sicherheitstrenntransformator 230 24 VAC 50Hz 28VA Klemmenleiste Netz Steuerung L N PE 230VAC 50Hz N und PE Verteiler Klemmenleiste Verteiler f r 24VAC Klemmenleiste Verteiler f r DC GND Klemmenleiste Pressostate HD ND Klemmenleiste Leistungseinspeisung 3L PE 400VAC 50Hz Vier Wege Umschaltventil Abk rzungen Energieversorgungsunternehmen Sperre Mischer AUF Mischer ZU Bauteile sind extern beizustellen Wire jumper must be inserted if no utility blocking contactor is required contact open utility block heat pump off Remove if the second disable connector is used contact open heat pump off Wire jumper fault M1 compressor Hot water thermostat Swimming pool water thermostat Defrost end controller 2nd heat generator electric heating function selectable via controller Fuse for N1 relay outputs at J12 and J13 4 0 slow acting Fuse for N1 relay outputs at J15 to J18 4 0 slow acting High pressure switch Low pressure switch Hot gas thermostat Winding protection ventilator Remote
7. below 20 C during this process This ensures that the heat pump can be defrosted at any time 6 Set the minimum volume flow quantity on the overflow valve and heat circulating pump when all heating circuits are fully open and a heating water temperature in the buffer tank of approx 20 C is maintained 7 New buildings have an increased heat consumption on ac count of the energy required to dry them out This increased heat consumption means that marginally dimensioned heat ing systems can not always achieve the desired room tem perature In such cases we recommend keeping a 2nd heat generator on standby during the first heating period The limit temperature on the heat pump controller should also be turned up to 15 C 8 Maintenance Cleaning 8 1 Maintenance To protect the paintwork avoid leaning or putting objects on the device External heat pump parts can be wiped with a damp cloth and domestic cleaner A ATTENTION Never use cleaning agents containing sand soda acid or chloride as these can damage the surfaces To prevent faults due to sediment in the heat exchanger of the heat pump ensure that the heat exchanger in the heating system can not be contaminated We recommend protecting the evapo rator by installing a bird guard in the inlet duct At least 80 of the cross section of the grating should be open In the event that operating malfunctions due to contamination still occur the sys tem should be cleaned
8. fault indicator lamp relay module Power supply N1 24 V AC Low voltage inputs outputs Signal inputs outputs 230V AC Has no function Socket for operating panel Has no function Relay outputs for the control of system components Contactor for compressor Ventilator relay Electron remote fault indicator relay relay module Electron relay for swimming pool water circulating pump relay module Contactor suppl heating system Utility blocking contactor SPR auxiliary relay Compressor Ventilator Heat circulating pump of the main circuit Heat circulating pump for heating circuit 2 Auxiliary circulating pump Hot water circulating pump Swimming pool water circulating pump Mixer for main circuit Mixer for heating circuit 2 Heat pump controller Soft start control for compressor Relay module Operating element External temperature sensor Return flow sensor for heating system Hot water sensor as an alternative to the hot water thermostat Sensor for heating circuit 2 Flow sensor Safety isolating transformer 230 24 V AC 50 Hz 28 VA Terminal strip mains control L N PE 230 V AC 50 Hz N and PE terminal block Terminal strip terminal block for 24 V AC Terminal strip terminal block for DC GND Terminal strip pressure switches HP LP Terminal strip power supply 3L PE 400VAC 50Hz Four way valve Abbreviations Utility company Block Mixer OPEN Mixer CLOSED Components to be supplied from ex
9. suitable for operation with a frequency converter 2 2 Operating Principle Outside air is drawn in by the ventilator and fed via the evapora tor heat exchanger The evaporator cools the air i e it extracts heat from it This extracted heat is then transferred to the working medium refrigerant in the evaporator The heat is pumped to a higher temperature level by increasing its pressure with the aid of an electrically driven compressor It is then transferred to the heating water using the liquifier heat ex changer Electrical energy is used to raise the temperature of the heat in the environment to a higher level Because the energy extracted from the air is transferred to the heating water this type of device is called an air to water heat pump The air to water heat pump consists of the main components evaporator ventilator and expansion valve as well as the low noise compressor liquifier and electrical control system At low ambient temperatures humidity accumulates on the evap orator in the form of frost reducing the transfer of heat The evap orator is defrosted automatically by the heat pump as required Steam may be emitted from the air outlet depending on the at mospheric conditions E 3 3 Scope of Delivery 3 1 Basic Device The compact heat pump is supplied complete with all of the im portant components of the heating circulation system Expansion vessel Heat circulating pump Overfl
10. An all pole disconnecting device with a contact gap of at least 3 mm e g utility blocking contactor or power contactor as well as a 3 pole circuit breaker with common tripping for all external conductors must be installed in the power supply tripping current in compliance with the Device Information Ensure that the incoming supply has a clockwise rotating field when connecting multiphase devices L1 L2 L3 A ATTENTION Ensure that there is a clockwise rotating field Operating the compressor in the wrong rotational direction could cause damage to the compressor The control voltage must be protected by a 10 A fuse For de tailed information see Circuit Diagrams in the Appendix E 6 7 Start UP 7 1 General Information To ensure that start up is performed correctly it should only be carried out by an after sales service technician authorised by the manufacturer This may be a condition for extending the guaran tee see Warranty Service 7 2 Preparation The following items need to be checked prior to start up All ofthe heat pump connections must be established as de scribed in Chapter 6 All valves that could impair the proper flow of the heating water in the heating circuit must be open m The air intake and air outlet paths must be clear m The ventilator must turn in the direction indicated by the row The heat pump controller must be adapted to the heating system in accordance with the contro
11. D bit d eau de chauffage en m h Air inlet temperature in C Temp rature d entr e d air en C 3 1 Steuerung Control Commande 3 Stromlaufplane Circuit Diagrams Sch mas lectriques 3 1 soxeuuy xipueddy 6ueuuy gt lt LIL T8 I a FL TEL DE Te Ze TS rar TE zu st ryz hey ZHOS 9 OEZ NE S Y SUJEN ZION rev zV 2 24 EM 1 3d N LA D 02 O LX 6 vL i L S 8 ez3 p E L fe ola E m 2 PN T r3 Zd 4 Q EJ Y Eq 3 T Q 2 XO Da er 4 eg OVAVZ cx OWA 5 95 5 56 15 5 jo 5 K I lt gt lt lt _ 5 ap EEE ee S 26 5 5 ON ZLF oom sr SP sonar PT roar sr LH L_ _ _ _ 7021170231 Ki 2 9 3 2 3 2 Last Load C
12. LIK 8 X Dimplex Montage und Gebrauchsanweisung Installation and Operating Instructions Instructions d installation et d utilisation 5 Luft Wasser Air to Water Pompe a chaleur W rmepumpe f r Heat Pump for air eau pour Innenaufstellung Indoor Installation installation int rieure Bestell Nr Order no N de commande 452160 66 01 FD 8611 Table of contents 1 Please Read Immediately UU U E 2 1 4 lu ien tele E 2 1 2 Legal Regulations and Directives sisi E 2 1 3 Energy Efficient Use of the 0000 E 2 2 Purpose of the Heat Pump aa Te re E 3 2 4 AppliGatlQri uu EES RE SEU E 3 2 2 Operating ci erede B a ine teet ede at 3 4 Scope e Du a u a te EE E 3 Ball r BASIC RE E 3 3 2 Switch BOX 07 E 4 3 3 Accessories Pack SERE Dnus E 4 5 c voit ernennen E 4 5 SeUP A 56 86 2 5 5 11 General Informations anne a a kl 5 5 2 Condensed Water sise 5 51952 SOU sas ite eve oh E 5 6
13. Use the same mounting procedure as for the air inlet If a flange mounted air duct is used on the air outlet side it is se cured with 4 M8 x 16 hexagon bolts in the threaded holes pro vided When doing this ensure that the air duct stubs only touch the insulation There should be no contact with the external sheeting max 532 Observe the external and internal dimensions as specified in the figure Also ensure that the vibration and duct isolation are ade quate 6 3 Heating System Connection To enable connection to the heating system flexible hose con nection pieces and double nipples with a 1 external thread are included with the heat pump These allow the optional use of a threaded or flat gasket connection to the heating system If the heat pump is not intended to be used to heat up the hot wa ter the hot water output must be permanently sealed using the supplied sealing plug Before connecting the heating water system to the heat pump the heating system must be flushed to remove any impurities residue from sealants etc Any accumulation of deposits in the liquifier could cause the heat pump to completely break down www dimplex de 6 4 An overflow valve is installed in the device for systems in which the heating water flow can be shut off via the radiator or thermo stat valves This ensures a minimum heating water flow rate through the heat pump and helps to avoid faults Once the heating sys
14. as described below 8 2 Cleaning the Heating System The ingress of oxygen into the heating water circuit may result in the formation of oxidation products rust particularly if steel components are used These products enter the heating system via the valves the circulating pumps and or plastic pipes It is therefore essential in particular with respect to the piping of un derfloor heating systems that only diffusion proof materials are used A ATTENTION We recommend the installation of a suitable corrosion protection system to prevent the formation of deposits e g rust in the condenser of the heat pump Residue from lubricants and sealants may also contaminate the heating water In the case of severe contamination leading to a reduction in the performance of the liquifier in the heat pump the system must be cleaned by a heating technician According to today s state of knowledge we recommend using a 5 phosphoric acid solution for cleaning purposes However if cleaning needs to be performed more frequently a 5 formic acid solution should be used In either case the cleaning fluid should be at room temperature We recommend flushing the heat exchanger in the direction op posite to the normal flow direction To prevent acidic cleaning agents from entering the heating sys tem circuit we recommend connecting the flushing device di rectly to the flow and return flow of the liquifier of the heat pump It is impo
15. directives circulation par notre soci t est sont der EG Richtlinien entspricht entsprechen conforme s aux directives fondamentales This declaration becomes invalidated CEE aff rentes Bei einer nicht mit uns abgestimmten if any modifications are made to nderung des der Ger t e s verliert the product s without our prior Ce certificat perd sa validit pour tout diese Erkl rung ihre G ltigkeit authorisation appareil modifi sans notre consentement Bezeichnung Designation D signation EG Richtlinien EC Directives Directives CEE Luft Wasser W rmepumpen EG Niederspannungsrichtlinie EC Low Voltage Directive f r Innenaufstellung mit R404A Directive CEE relative la basse tension 2006 95 Air to water heat pumps EG EMV Richtlinie EC EMC Directive Directive CEE for indoor installation containing R404A relative la compatibilit lectromagn tique 89 336 EWG Pompes chaleur air eau Druckgerdterichtlinie Pressure Equipment Directive pour installation int rieure avec R404A Directive CEE relative aux appareils sous pression 97 23 EG x lt 2s S E 2 Harmonisierte Harmonized EB Standards Normes EN harmonis es LIK 8 EN 255 1997 EN 378 2000 DIN 8901 DIN EN 60335 1 VDE 0700 T1 2006 EN 60335 1 2002 A11 A1 A12 Corr A2 2006 DIN EN 60335 2 40 VDE 0700 T40 2006 11 60335 2 40 2003 A11 A12 A1 C
16. e maximum temperature spread between the heating flow and re turn flow listed in the following table for the current heat source temperature The temperature spread should be measured as close as possible to the heat pump The heating element of mono energy systems should be disconnected E 7 Heat source Max temperature spread temperature between heating flow and return From To flow 20 C 15 4K 44 10 C 5K 9 5 4 0 1 5 8K 6 10 C 9K 11 15 10K 16 C 20 C 11K 21 25 12K 26 30 13K 31 35 14K Any faults occurring during operation are also displayed on the heat pump controller and can be corrected as described in the operating instructions of the heat pump controller For external temperatures below 10 C and heating water tem peratures below 16 C the buffer tank should be heated up with the 2nd heat generator to at least 25 C Observe the following procedure to implement a smooth start up 1 Close all of the heating circuits Fully open the overflow valve 3 Use the controller to select the automatic operating mode Wait until the buffer tank has reached a temperature of at least 25 C 5 Now slowly reopen the heating circuit valves in succession so that the heating water throughput is constantly raised by slightly opening the respective heating circuit The heating water temperature in the buffer tank must not be allowed to drop
17. e circuit de chauffage Circulateur suppl mentaire Circulateur d eau chaude Circulateur d eau de piscine M langeur circuit principal M langeur 2e circuit de chauffage R gulateur de pompe chaleur Commande de d marrage progressif pour com presseur Module de relais Commande Sonde de temp rature ext rieure Sonde retour chauffage Sonde d eau chaude alternative au thermostat eau chaude Sonde pour le 2e circuit de chauffage Sonde aller Transformateur sectionneur de s curit 230 24 VAC 50Hz 28VA Bornier distributeur commande secteur L N PE 230V AC 50 Hz distributeur N et PE Bornier distributeur distributeur pour 24 V AC Bornier distributeur distributeur pour DC GND Bornier distributeur pressostats HD ND Bornier distributeur alimentation puissance 3L PE 400 V AC 50 Hz Vanne d inversion 4 voies Abr viations Soci t de production et de distribution d nergie Blocage M langeur OUVERT M langeur FERME Pi ces fournir par le client 4 1 4 Hydraulisches Prinzipschema Hydraulic Plumbing Diagram Sch ma hydraulique 41 Darstellung Schematic view Repr sentation LOUE R1 x 4 2 S lt lt KW 2 2 www dimplex de A IX gt 5 5 D 5 gt 5 5 5 x gt 5 5 x 4 2 4 2 Legende Legend L gende OX X x O ER X
18. e heat pump ensure that it is not tilted more than 45 in any direction A ATTENTION The heat pump and the wooden pallet are only joined by the packing film A ATTENTION Do not restrict or block the area around the air intake or outlet A ATTENTION In the case of large volume heating circuits an additional expansion vessel must be used to supplement the installed expansion vessel 24 litres 1 0 bar admission pressure A ATTENTION Ensure that there is a clockwise rotating field Operating the compressor in the wrong rotational direction could cause damage to the compressor A ATTENTION Never use cleaning agents containing sand soda acid or chloride as these can damage the surfaces A ATTENTION We recommend the installation of a suitable corrosion protection system to prevent the formation of deposits e g rust in the condenser of the heat pump A ATTENTION Before opening the device ensure that all circuits are isolated from the power supply ATTENTION Work on the heat pump may only be carried out by authorised and qualified after sales service technicians www dimplex de 1 3 1 2 Legal Regulations and Directives The construction and design of the heat pump complies with all relevant EU directives DIN VDE regulations see CE declaration of conformity When connecting the heat pump to the power supply the rele vant VDE EN and IEC standards are to be fulfilled Any furthe
19. formitatserklarung Declaration of Conformity D claration de conformite A XI www dimplex de A l o x T 2 t s imension Drawings Sch mas co 1 Ma bilder D ub 7 emos nea ued q ap ap joulqoy ub 4 EI suep oam xnyay feat el emos ep nee Jolly 886 6 eDejjneuo ep uoisseidins Og jesuepuoo np 3 9 9 Xy Warmepumpe Heat pump Pompe a chaleur 1 1 peauy Jap Bue sny JOH 10910 89996 0 de pue 4 SpeoJuj pue UJnj8J peasy Bur uugusBunu pu3 pun 04 6 y Bune u e nssa d a O 2 pisu oe e jesu puoo X 8W peasy x p 00 epuiweBuesgny ueuu dM BueBur3 wog jneppony
20. h and exhaust air W Flow and return flow of the heating system Condensate outflow m Outflow for the pressure relief valve Power supply 6 2 Air Connection A ATTENTION Do not restrict or block the area around the air intake or outlet The air intake opening of the device is solely designed for direct connection to a wall opening The wall opening can be provided with air duct and sealing collar for this purpose See the illustra tion in the appendix under Installation Dimensions The glass fibre reinforced concrete air ducts offered as accesso ries are moisture resistant and diffusion free The sealing collar is used to seal the air ducts on the heat pump The air ducts are not screwed directly onto the heat pump Only the rubber seal comes into direct contact with the heat pump when the system is installed correctly This guarantees easy as sembly and disassembly of the heat pump and also ensures that solid borne sound is well insulated S gt It must also be ensured that the interior side of the wall opening is lined with thermal insulation to prevent the wall from becoming cold and to prevent moisture from penetrating the wall The en closed fixing accessories can be used for attachment to the wall The air outlet can be optionally mounted directly to a wall open ing or to a longer duct available as an accessory
21. harge DLC Anhang Appendix Annexes ZHOS 6 suley ZION T Joynquysip Ju 3 3 soxeuuy xipueddy 6ueuuy ZHOS OVAOOF 3d SUIEN ZHOS OWA OC 2 9 l N _ 5 _ An tee 5 SX 1 17 LX m 5 me s 8 d rm m 24 es gt L gt L va e LE 5 15 0 0 mum lt Q z 8g 5 8 Poe ccm jt L us ss 1 O S mE j or er a g r er air Ges ze 21012 z 0 z o z 2 2 0 z o z 12 0 91212 z z o 30000 E das 5 2 EN Em Of 5552 1o SCH i ag D D a o ZZN SIN Sie Sun ven Su 63 lt e
22. ller s operating instruc tions Ensure the condensate outflow functions m The outflow from the heating water pressure relief valve must also function correctly De aeration of the heating system Ensure that all heating circuits are open and the heat circu lating pump is operating level Ill Connect the voltage to the heat pump controller Select the heat generator 2 operating mode and de aerate the system at its highest point Top up with water if required maintain static minimum pressure 7 3 Start Up Procedure The heat pump is started up via the heat pump controller Adjust ments should be made in compliance with the instructions The performance level of the circulating pump must be adapted to the respective heating system The overflow valve must be adjusted to the requirements of the respective heating system Incorrect adjustment can lead to faulty operation and increased energy consumption We recom mend carrying out the following procedure to correctly adjust the overflow valve Close all of the heating circuits that may also be closed during operation depending on the type of heat pump usage so that the most unfavourable operating state with respect to the water flow rate is achieved This normally means the heating circuits of the rooms on the south and west sides of the building At least one heating circuit must remain open e g bathroom The overflow valve should be opened far enough to produce th
23. net d arr t avec coulement Consommateur de chaleur Sonde de temp rature Tuyau de raccord flexible Pompe chaleur R servoir tampon R gulateur de pompe chaleur Distributeur courant lectrique Ballon d eau chaude Ecoulement des condensats Surpression eau de chauffage Chauffage d appoint Circulateur de chauffage Circulateur d eau chaude R gulateur de pompe chaleur Sonde de temp rature ext rieure Sonde de retour Sonde d eau chaude Distributeur courant lectrique Eau froide M langeur OUVERT Eau chaude 5 Konformitatserklarung Declaration of Conformity D claration de conformit EG Konformit tserkl rung EC Declaration of Conformity D claration de conformit Der Unterzeichnete Glen Dimplex Deutschland GmbH The undersigned Gesch ftsbereich Dimplex La soci t soussign e Am Goldenen Feld 18 D 95326 Kulmbach best tigt dass das die nachfolgend be hereby confirm that the design and con certifie que l appareil les appareils ci zeichnete n Ger t e aufgrund seiner ihrer struction of the product s listed below apr s par leur conception et leur mode de Konzipierung und Bauart sowie in der von in the version s placed on the market by construction ainsi que par la d finition uns in Verkehr gebrachten Ausf hrung den us conform to the relevant requirements technique avec laquelle il s sont mis en einschl gigen grundlegenden Anforderungen the applicable EC
24. omer Mousse de construction courante a fournir par le client SS 2 Dichtmanschette als Zubeh r erh ltlich Sealing collar available as an accessory Manchon d tancheit disponible en accessoire 3 Luftkanal als Zubeh r erh ltlich Air duct available as an accessory Conduit d a ration disponible en accessoire 4 Umlaufende Abschr gung bauseits zur Abdichtung der StoRkante und Verbesserung der Luftf hrung Continuous chamfer to be provided by the customer to seal the border and to facilitate air circulation Chanfrein p riph rique fournir par le client assurant l tanch it du bord et am liorant la conduite de l air Einsatz eines Dammstreifens unter der Warmepumpe muss das Ma entsprechend erh ht werden The dimensions must be increased correspondingly when an insulating strip is used under the heat pump En cas d utilisation d une bande isolante sous la pompe a chaleur augmenter la cote en correspondance A III o x s 2 lt 2 Diagramme Diagrams Diagrammes 2 1 Kennlinien Characteristic Curves Courbes caract ristiques Heizleistung in KW Wasseraustrittstemperatur in C Heating capacity in KW Water outlet temperature in C Puissance de chauffage en KW Temp rature de sortie de l eau en C 35 14 Bedingungen Conditions Conditions 50 Heizwasserdurch
25. orr 2006 DIN EN 55014 1 VDE 0875 14 1 2003 09 EN 55014 1 2000 A1 2001 A2 2002 DIN EN 55014 2 VDE 0875 T14 2 2002 08 EN 55014 2 1997 A1 2001 DIN EN 61000 3 2 VDE 0838 T2 2005 09 EN 61000 3 2 2000 A2 2005 DIN EN 61000 3 3 VDE 0838 T3 2002 05 EN 61000 3 3 1995 Corr 1997 A1 2001 Nationale Richtlinien National Directives Directives nationales D A CH BGR 500 SVTI Kulmbach 30 01 2007 Wo old Andreas Fi Gesth fisf hrer Managing Director Spartenleiter Head of business unit CE11WOll doc www dimplex de Glen Dimplex Deutschland GmbH Irrt mer und nderungen vorbehalten Gesch ftsbereich Dimplex Subject to alterations and errors Am Goldenen Feld 18 Sous r serve d erreurs et modifications D 95326 Kulmbach amp 49 0 9221 709 565 www dimplex de
26. ow valve and safety components pressure relief valve pressure gauge R404A is used as the refrigerant 1 Evaporator 2 Ventilator 3 241 expansion vessel 4 Switch box 5 Liquifier 6 Compressor 7 Overflow 8 Heat circulating pump 9 Buffer tank 10 Filter dryer 11 Inspection window 12 Expansion valve 3 2 Switch Box The switch box is located in the heat pump It can be accessed by removing the lower front cover The switch box contains the supply connection terminals as well the power contactors the soft starter unit and the heat pump manager The heat pump manager is a convenient electronic regulation and control device The enclosed operating instructions describe the function and use of the heat pump manager 3 3 Accessories Pack Contents Sealing rings for duct connection 1 connecting hoses 1 double nipples 1 flat gaskets 1 sealing plug Hose nozzle for filling and drain cock Fixing brackets 10 mm dowels 8 x 80 screws M4 x 8 screws External sensor 6 mm dowels 4 5 x 50 screws PR D ND N www dimplex de 4 Transport N ATTENTION When transporting the heat pump ensure that it is not tilted more than 45 in any direction Use a wooden pallet for transporting the heat pump to the final in stallation location The basic device can be transported with a lift truck hand truck or by means of 3 4 pipes fed through the holes in the base plate o
27. r connection requirements stipulated by local utility companies must also be observed When connecting the heating system all applicable regulations must also be adhered to Persons especially children who are not capable of operating the device safely due to their physical sensory or mental abilities or their inexperience or lack of knowledge must not operate this device without supervision or instruction by the person in charge Children must be supervised to ensure that they do not play with the device 1 3 Energy Efficient Use of the Heat Pump With the purchase of this heat pump you are helping to protect the environment A prerequisite for energy efficient operation is the correct design of the heat source system and heating system radiators and circulation pump It is particularly important for the efficiency of a heat pump to keep the temperature difference between heating water and heat Source as small as possible For this reason it is advisable to de sign the heat source and heating system very carefully A tem perature difference of approx one Kelvin 1 C increases the power consumption by around 2 5 When designing the heating system it should be borne in mind that special consum ers such as e g hot water preparation should also be considered and dimensioned for low temperatures Underfloor heating systems panel heating are optimally suited for heat pump use on account of the low flow temperatures 30 C
28. r frame A ATTENTION The heat pump and the wooden pallet are only joined by the packing film Before using the holes in the frame it is advisable to remove each of the side panel assemblies This is done by loosening each of the two screws at the base and then withdrawing the panels by unhooking them from above Rehang the panels by gently pushing them in an upwards direction SA N 3 2 A LA a e Opening the cover ov 2 Closing the cover E 4 5 Set UP 5 1 General Information The heat pump is designed for installation in a corner Other in stallation locations are also possible in combination with an air duct available as an accessory on the air outlet side The unit must be installed indoors on a level smooth and hori zontal surface The entire base of the frame should lie directly on the floor to ensure a good soundproof seal If this is not the case additional sound insulation measures may be necessary The heat pump must be installed so that maintenance work can be carried out without being hindered This can be ensured by maintaining a clearance of 1 m in front and to the left of the heat pump The side panel assemblies must not be covered by connecting pipes 1m 1m Never install the device in rooms subject to high humidity Con densation can form on the heat pump and air circuit if the humid i
29. rtant that the system be thoroughly flushed using appro priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system Acids must be used with great care and all relevant regulations of the employers liability insurance associations must be adhered to If in doubt contact the manufacturer of the chemicals The buffer tank is drained using the filling and drain cocks on the lower left of the device Also open the ball valve on the pressure expansion vessel to vent the buffer tank www dimplex de 10 8 3 Cleaning the Air System Air ducts evaporator ventilator and condensate outflow should be cleaned of contamination leaves twigs etc before the heat ing period Do this by opening the left and front sides of the heat pump The bottom should be opened first followed by the top A ATTENTION Before opening the device ensure that all circuits are isolated from the power supply Remove and rehang the side panel assemblies as described in Chapter 4 To prevent the evaporator and the condensate tray from being damaged do not use hard or sharp objects for cleaning 9 Faults Trouble Shooting This heat pump is a quality product and is designed for trouble free and maintenance free operation In the event that a fault should occur it will be shown on the heat pump manager display Simply consult the Faults and Trouble shooting page in the oper ating instructions of
30. satz F Heating water flow rate 12 D bit d eau chauffage 0 8 5 10 gt 2 E z 5 2 Q L ol KE 20 10 0 10 20 30 40 5 Lufteintrittstemperatur in C Air inlet temperature in C Temp rature d entr e d air en C x Leistungsaufnahme incl Pumpenleistungsanteil Druckverlust in Pa gt Power consumption incl power input to pump Pressure loss in Pa 3 Consommation de puissance y compris part de consommation de la pompe Perte de pression en Pa 5 4 9000 E E 50 3 35 8000 F P E Verfl ssiger 2 Condenser 7000 Condenseur 11 6000 0 rcr 08 UNS ER BR E PSE dI dis 20 10 0 10 20 30 40 5000 Lufteintrittstemperatur in C E Air inlet temperature in C E Temp rature d entr e d air en C 4000 Leistungszahl incl Pumpenleistungsanteil E Coefficient of performance incl power input to pump 3000 6 Coefficient de performance y compris part de consommation de la pompe E 5 2000 4 3 1000 2 E 1f e E 0 02 04 06 08 1 12 14 0 Heizwasserdurchfluss in m h 20 10 0 10 20 30 40 Heating water flow rate in m h INN Lufteintrittstemperatur in C
31. tem has been installed it must be filled de aerated and pressure tested The integrated expansion vessel has a volume of 24 litres This volume is suitable for buildings with a living space area to be heated of maximum 200 m The volume should be checked by the heating system engineer If necessary an additional expansion vessel must be installed according to DIN 4751 Part 1 The tables listed in the manufac turers catalogues simplify dimensioning the system on the basis of the water content Allow for a buffer tank volume of 80 litres when making the calculation A ATTENTION In the case of large volume heating circuits an additional expansion vessel must be used to supplement the installed expansion vessel 24 litres 1 0 bar admission pressure Antifreeze A method of manual drainage see illustration should be pro vided for heat pumps which are exposed to frost The antifreeze function of the heat pump controller is active whenever the con troller and the heat circulating pumps are ready for operation If the heat pump is taken out of service or in the event of a power failure the system has to be drained The heating circuit should be operated with a suitable antifreeze if heat pump systems are implemented in buildings where a power failure can not be de tected holiday home 6 4 Electrical Connection The power supply and control voltage are supplied using stand ard cables load 4 core control 3 core
32. ternal sources Cavalier a monter en absence de contacteur de coupure du fournisseur d nergie pont ouvert coupure soci t lectricit pompe a chaleur arr t e Cavalier a fil a retirer si la 2e entr e de coupure est utilis e pont ouvert pompe a chaleur arr t e Cavalier dysfonctionnement compresseur M1 Thermostat eau chaude Thermostat eau de piscine Pressostat fin de d givrage 2e g n rateur de chaleur chauffage lectrique fonction r glable par le r gulateur Fusible pour sorties de relais N1 en J12 et J13 4 0 ATr Fusible pour sorties de relais 1 en J15 jusqu J18 4 0 ATr Pressostat haute pression Pressostat basse pression Thermostat gaz de chauffage Blindage de l enroulement ventilateur T moin de t l d tection de pannes sur module de relais Alimentation en courant N1 24 V AC Entr es et sorties de basse tension Entr es et sorties de signaux 230 V AC Sans fonction Prise pour le panneau de commande Sans fonction Sorties de relais pour la commande des compo sants du syst me Contacteur compresseur Relais ventilateur Relais pour t l d tection de pannes sur module de relais Relais pour circulateur d eau de piscine sur module de relais Contacteur 2 me g n rateur de chaleur Contacteur de coupure du fournisseur d nergie Relais auxiliaire SPR Compresseur Ventilateur Circulateur de chauffage circuit principal Circulateur de chauffage 2
33. the heat pump manager If you cannot cor rect the fault yourself please contact your after sales service technician A ATTENTION Work on the heat pump may only be carried out by authorised and qualified after sales service technicians 10 Decommissioning Disposal Before removing the heat pump disconnect it from the power source and close all valves Observe all environmentally relevant requirements regarding the recovery recycling and disposal of materials and components in accordance with all applicable standards Particular attention should be paid to the proper dis posal of refrigerants and refrigeration oils E 8 11 11 Device Information 2 1 2 2 2 3 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 4 1 4 2 4 3 4 4 4 5 4 6 5 1 5 2 5 3 5 4 7 1 7 2 7 3 7 4 Type and order code Design Model Degree of protection according to EN 60 529 for compact devices and heating components Installation location Performance data Operating temperature limits Heating water flow return flow cic Air Temperature spread of heating water flow return flow at A7 W35 Heat output COP at 7 W35 kW at 7 W45 1 kW at 2 W35 kW at 7 W35 1 kW at 7 W45 kW at 10 W35 1 kW Sound power level device outdoors dB A Sound pressure level at a distance of 1 m indoors dB A Heating water flow with an internal pressure differential of
34. to 40 C It is important to ensure that the heat exchangers are not con taminated during operation because this increases the tempera ture difference in turn reducing the COP Correct adjustment of the heat pump controller is also important for energy efficient use of the heat pump Further information can be found in the heat pump controller s operating instructions The heat pump is equipped with an overflow mechanism to pre vent very low flow rates in the heat pump The installed buffer tank increases the amount of water in the heating circuit and guarantees reliable defrosting E 2 2 Purpose of the Heat Pump 2 1 Application The air to water heat pump is designed for use in existing or newly built heating systems It is designed exclusively for heating domestic and heating water The heat pump is suitable for mono energy and bivalent opera tion down to an external temperature of 20 C Proper defrosting of the evaporator is guaranteed by maintaining a heating water return flow temperature of more than 18 C dur ing continuous operation The heat pump is not designed for the increased heat consump tion required when a building is being dried out The additional heat consumption should be met using special devices provided by the customer If a building is to be dried out in autumn or win ter we recommend installing an additional heating element available as an accessory ATTENTION The device is not
35. ty exceeds 50 and the external temperature is below 0 C If the heat pump is installed on an upper storey the load bearing capacity of the ceiling should be checked On account of the acoustics measures for isolating possible vibrations should also be very carefully planned in advance as well Installation on a wooden floor is not recommended 5 2 Condensed Water Pipe Condensed water that forms during operation must be drained off frost free The heat pump must be mounted on a level plane to guarantee proper drainage The condensed water pipe must have a minimum diameter of 50 mm and should be fed frost free into a sewer Condensate should not be discharged directly into clearing tanks and cesspits because the aggressive vapours could destroy the evaporator 5 3 Sound To prevent solid borne sound from being transmitted to the heat ing system a vibration damped connection should be used for connecting the heat pump with the heating system install the supplied hose connections free of strain Installed air ducts should be sound isolated from the heat pump to prevent the transmission of solid borne sound to the ducts If both air openings are connected directly to a wall opening the ventilator terminals can be reversed from a delta to a star con nection see information in the ventilator terminal box E 5 6 Installation 6 1 General Information The following connections need to be established on the heat pump Fres
36. y efficiency of the system other parameters such as particular the defrosting capacity the bivalence point and regulation should also be taken into consideration The specified values e g A2 W55 have the following meaning External temperature 2 C and heating water flow temperature 55 C The heat circulating pump is integrated See CE declaration of conformity The heat circulating pump and the heat pump controller must always be ready for operation Anhang Appendix Annexes 1 MaBbilder Dimension Drawings Sch mas cot s A ll 1 1 W rmepumpe Heat pump Pompe chaleur iii 1 1 2 Einbauma e Installation Dimensions Cotes de montage A III Diagramme Diagrams A IV 2 1 Kennlinien Characteristic Curves Courbes caract ristiques A IV Stromlaufpl ne Circuit Diagrams Sch mas lectriques A V 3 1 Steuerung Control A V 3 2 East Load 7 Chliarge ete Tte tret boe etae eue A et benc Ete e Te A VI 3 3 Anschlussplan Circuit Diagram Sch ma lectrique A VII 3 4 Legende Legend L gende usine A VIII Hydraulisches Prinzipschema Hydraulic Plumbing Diagram Sch ma hydraulique 4 1 Darstellung Schematic view Repr sentation ss 4 2 Legende Legend Kon