Home

Operating Instructions Busch-Dimmer® Busch - Busch

image

Contents

1. 6020 6021 IR receiver e For controlling built in devices 6420 EB 6056 EB With a feed line of approximately 0 5 m feed line cannot be extended Length of the linear lamp 30 mm e Operation is only possible via manual or wall mounted transmitter 6010 6020 6021 Operating Instructions 1473 1 7919 Operating Instructions Busch Dimmer 6 2 Possible combinations 6420 EB no _Y jad 6045 6045 E 6010 25 AAA x X 6020 er x X 6021 X 6056 EB xX Setup and function Operating Instructions 1473 1 7919 Operating Instructions Busch Dimmer Installation and electrical connection T Installation and electrical connection 7 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience e Incorrect installation endangers your life and that of the user of the electrical system e Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows e Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts e Use suitable personal protective clothing e U
2. MEMO storage EVERYTHING OFF O Note on the dimming functions The functions of the controller can only be used in connection with fluorescent lamps with a ballast 1 10 V control input The relevant operating manuals of the IR remote control and wall mounted transmitter provide information about the design of the above mentioned functions 5 Technical data General Nominal voltage 230 V AC 10 50 Hz Nominal power 500 W VA Fluorescent lamps in genera no parallel compensation Control current 50 mA Setting time Approximately 5 seconds from basic brightness to maximum brightness Radio interference suppression EN 55015 Short circuit protection Extend external primary side type T 3 15 H MEMO storage At mains power failure gt 8 hours Ambient temperature range 0 60 C Light conducting rod 18 mm 75 taper IR receiving range Approximately 15 m 0 line see Fig 4 Operating Instructions 1473 1 7919 ny en Operating Instructions Busch Dimmer Setup and function 6 Setup and function The device is intended for the activation of the following type of load C Electronic ballasts for fluorescent lamps 6 1 Features of function and equipment IR dimmer controller e For installation in fluorescent lamps e For controlling electronic ballasts for fluorescent lamps with control output 1 10 V DC e Operation is only possible via manual or wall mounted transmitter 6010
3. 1473 1 7919 Rev 01 17 12 2012 Busch Ferncontrol IR IR Dimmer 6045 500 Built in IR receiver 6045 E 101 500 Power and productivity Ah ab ae for a better world PA lp ap Operating Instructions Busch Dimmer 1 A ntassadecnasyacssdguieh A 3 2 TINLGMOS OWS PP E seecectesanst as tcutees centre aap saaltesena ide scecengesaay Sus toe taaseaeecs santa tuagesaeseaapacpdasaoseeetkanaapieeaaes 3 3 EMMONS 0 deerme en crete E ce n rer rere Sono rere errr 3 4 OPS RAN OM 253 Ao A O 4 5 fife al gle ke f Preemeeererer a a erreeet ey rere tere pee rerrer rect reer renee eer rer eet renee eer eeerree 4 6 Setup and TUMEU OM sates caches no dag cances ee cseus tua di eacecens cudneesteaceee A a Ea 5 6 1 Features of function and CQUIPMENL ee cence eeenneeeceeeeeee eee ee eeeaaeeeseeeaeeeeaeeeeesaaeeeeeeaaeeeseeeeeeeenaeeeeeaas 5 6 2 Possible combinations i aiii chdbidl aa a e a ea iva ies a 6 7 Installation and electrical COMNNEGHON cerrara T 7 1 Requirements for the GleCtrician isiin ie R a eaaa 7 7 2 MOUNTING iinei e iii 7 8 COMME CUO iii oa EE AAE EE AEE A AEO EE RE 10 9 COMMISSIONING ss sisi isla a 10 9 1 Address lessee ctuteds erno ee ai naaie e Ora fees ances ehoani at ca tentanitersedeas a Oea rs 10 10 Eaulbieciica lonas ist toi o isos 11 Operating Instructions 1473 1 7919 2 Operating Instructions Busch Dimmer Safety 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltag
4. 2 IR receiver 3 Electronic ballast 4 RC suppressor 1 Connect the RC suppressor to the electronic ballast Caution Impairement of function Do not install the cable of the receiver parallel to the load line 2 Establish the electrical connection between the receiver and the controller 9 Commissioning 9 1 Addressing The address of controller is is set on number 1 at the factory The address can be A5 changed with the address wheel on top of the controller oy 1 Set the desired address N N 2 Observe the IR receiving range when addressing see Fig 4 y o Operating Instructions 1473 1 7919 40 Operating Instructions Busch Dimmer 10 Fault rectification Fault rectification Diagnosis LED off Possible cause External fuse is defective Fault rectification Replace fuse Strong component of extraneous light Reduce extraneous light component No mains power Check mains voltage LED flashes continuously Permanent extraneous infrared signal Search for and deactivate extraneous transmitter LED does not flash at transmission signal LED does not flash at transmission signal receiver load does not respond O Note on reception The IR receiving range may vary due to extraneous light e g No incoming IR signal Check position of linear lamp and ensure that it is not covered Battery of IR remote control or wall mounted transmitter is empty Replace batte
5. e of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 7919 3 Operating Instructions Busch Dimmer Operation 4 Operation The receiver can only be used with an infrared remote control and wall mounted transmitter All infrared functions short IR functions are available Switching ON e Switching OFF e Adjusting BRIGHTER Adjusting DARKER
6. n adherence to the receiving characteristics see Fig 4 the brightness at the mounting position must not exceed 200 lux Please ensure that there is a sufficiently large distance to the scattered light of the fluorescent lamp since it contains infrared components and can therefore impair the reception The cable of the IR receiver must under no circumstances be damaged or extended Version 1 IR dimmer 6045 Fig 2 IR dimmer in fluorescent lamp 1 Electronic ballast 2 IR dimmer controller including receiver Operating Instructions 1473 1 7919 Operating Instructions Busch Dimmer Installation and electrical connection Version 2 IR built in receiver 6045 E 101 2 AA 1 EA Fig 3 IR built in receiver in fluorescent lamp 1 Built in device 6420 EB 6056 EB 2 IR receiver 100 ees 20 20 40 60 80 IN TOSS ie XK 0 Fig 4 IR receiving range Operating Instructions 1473 1 7919 9 Operating Instructions Busch Dimmer Connection 8 Connection 16A L e N RO 4 9 gt et e i L oN L iI EVG N O I 1 2 3 Fig 5 Circuit diagram 1 IR dimmer controller
7. ry IR transmission range exceeded Reduce the distance between transmitter and receiver Wrong address at receiver Correct the address Wrong address range on transmitter Correct the address Load is defective Replace load sunlight illumination Operating Instructions 1473 1 7919 11 Operating Instructions Busch Dimmer A member of the ABB Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstrafe 2 58513 L denscheid Germany www BUSCH JAEGER com info bje de abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB Copyright 2012 Busch Jaeger Elektro GmbH All rights reserved Power and productivity AA HE 4 for a better world PA E ae 1473 1 7919 Rev 01 17 12 2012
8. se only suitable tools and measuring devices e Check the supply network type TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthing necessary additional measures etc 7 2 Mounting Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly Caution Risk of damaging the device due to excessive voltages The switching of electronic ballasts can cause excessive voltages Use the enclosed RC suppressor to guarantee effective protection for the device see Electrical connection Do not use parallel compensated fluorescent lamps Operating Instructions 1473 1 7919 7 Operating Instructions Busch Dimmer Installation and electrical connection O Information for the connection of ballasts Please observe the following points regarding high inrush currents for ballasts With all electronic ballasts 2 x 58 W without an additional filter choke only one ballast may be connected e With ballasts 2 x 58 W with an additional filter choke a maximum of four ballasts may be connected 1 Install the controller and the receiver in the fluorescent lamp Fig 1 IR receiver with cable O Note on mounting the receiver For trouble free functio

Download Pdf Manuals

image

Related Search

Related Contents

詳細はこちらをクリックしてください  Configuration - Measurement Systems  T205 User Manual  TC-344C User`s Manual  One For All URC 6420 remote control  ZyXEL AG-220 User's Manual  Samsung D103 User's Manual  Intel Pentium SL2YM processor  分類 M. ~その他~  

Copyright © All rights reserved.