Home

none 608 Use and Care Manual

image

Contents

1. by pressing the ON OFF button The display will initially read 608 along with the selected unit of measure After this initial display the 608 is ready for use Note Follow these steps to change the unit of measure a With the 608 turned off press and hold the on off button until the display reads and the unit annunciator flashes b Release the on off button and then press it repeatedly until the desired unit of measure is displayed The unit of measure will cycle through inH20 mbar KPa and PSI c Once the desired unit of measure is selected allow the 608 to turn off and then turn it back on and proceed with testing The 608 will turn on in the last selected unit of measure until changed 2 Zero the displayed reading by pressing the ZERO button 3 Connect the 608 to the device under test Additional Features Backlight The backlight can be activated to make the display easier to see in dark environments Press the BL button to turn the backlight on The display will light up and BL will be displayed To preserve battery life the backlight will remain on for 15 seconds and then turn off Auto Power Off To extend battery life the 608 will automatically turn off after 20 minutes Case Magnets The 608 back case is equipped with magnets and a hook and Hook This allows the 608 to be secured during tests F ACCESSORIES Item Description AOOQA o n 9 Volt Alkaline Battery included ATIA
2. ee es Silicone tubing included AVOO ninn Soft Carrying Pouch optional G MAINTENANCE 1 Clean the surface of the instrument using a damp cloth 2 Replace the 9 Volt battery when the low battery indicator appears on the LCD H TROUBLE SHOOTING Symptom Probable Cause Display reads oFL e Pressure over range e Low battery e Damaged sensor 608 does not turn on Dead or low battery Defective POWER ON switch e Broken battery connector WARRANTY This product is warranted to the purchaser against defects in material and workmanship for three years from the date of purchase Covered by Warranty Repair parts and labor or replacement of the product at company s option Normal transportation charges to the purchaser are also covered Not Covered by Warranty Damages to the product which are the result of abuse improper use or mainte nance are not covered Any other expense consequential damages incidental damages or incidental expens es including damages to property are not covered Transportation expenses to the company are not covered Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you To Obtain Warranty Performance Include with the product your name address phone number written description of the problem and proof of purchase date Carefully package and return to TPI Inc TPI Ltd TPI Euro
3. lini Digital Manometer 608 TestProducts International Inc 608 Digital Manometer The Value Leader Visit www testproductsintl com A INTRODUCTION 1 Congratulations Thank you for purchasing TPI products The 608 is easy to use and built to last Please remember to complete and return your product warranty registration card 2 Product Description The 608 digital manometer measures pressure or vacuum in four units of measure Please follow manufactures recom mendations on all equipment being serviced with the 608 B SAFETY CONSIDERATIONS 1 Wear safety gogles 2 Make sure system pressure does not exceed the capability of the 608 before connection Check all connections making sure they are secure with no leaks Observe all manufacturers recommendations C General Specifications Sensor Type Temperature compensated solid state Connector Type Standard 1 4 Barb Fitting Range 60 inH20 to 60 inH20 Units of Measure PSI mBar KPa inHo0 Over Pressure 120 inH20 Operating Temperature 14 to 122 F 10 to 50 C Power Supply 9 Volt Alkaline D Accurac Measurement Range Resolution Accurac inH20 0 01 to 29 99 0 01 0 3 inH20 we 30 0 to 60 0 0 1 0 6 inH50 0 01 to 29 99 0 1 1 5 mbar 0 001 to 2 999 0 001 0 03 KPa 3 00 to 15 00 0 01 15 KPa PSI Psi 0 001 to 2 175 0 001 0 021 PSI E MEASUREMENT TECHNIQUES 1 Turn the 608 on
4. pe Ltd 9615 SW Allen Blvd 342 Bronte Rd S Unit 9 Longley House East Park Beaverton OR 97005 Milton Ontario L9T 5B7 Crawley USA Canada West Sussex RH10 6AP England Implied Warranties Any implied warranties including implied warranties of merchantability and fitness for a particular purpose are limited in duration to three years from date of purchase To the extent any provision of this warranty is prohibited by federal or state law and cannot be preempted it shall not be applicable This warranty gives you specific legal rights and you may also have other rights which vary from state to state

Download Pdf Manuals

image

Related Search

Related Contents

  document PDF 250 Ko - Abbaye Saint  取扱説明書はこちら  guidepratique  Apparecchiatura di comando W-FM 54  939447 CL-HV01 - Electro Depot  Gebrauchsanweisung frontloaders 13.04.10 OK.cdr  C.A 6423  Numéro 2  LevelOne IES-0822  

Copyright © All rights reserved.
Failed to retrieve file