Ventamatic CX1500UPS Instructions / Assembly

image

Contents

1. locations readily accessible to people or animals Mount with the lowest moving parts at least 8 feet above floor level For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Carbon monoxide is an odorless colorless gas that can kill It may be drawn into the house by operating this fan if your fuel burning equipment is not properly maintained or if you lack adequate attic intake vents PHONE 800 433 1626 FAX 940 325 9311 www bvc com S VENTAMATIC LTD FE 100 WASHINGTON STREET MINERAL WELLS TX 76068 0728 Ventamatic INSTALLATION INSTRUCTIONS THIS GABLE MOUNTED UNIT IS DESIGNED FOR ATTICS OF AVERAGE SIZE AND OPERATES MOST EFFICIENTLY WHEN AIR INTAKES ARE LOCATED AROUND THE EAVES ALTERNATIVELY AIR INTAKE MAY BE FROM OPPOSING GABLE VENTS BUT NEVER FROM ROOF OR RIDGE VENTS AT LEAST 600 SQ IN OF NET FREE AIR INTAKE IS REQUIRED PER UNIT FOR SAFE AND EFFICIENT OPERATION THE MOTOR OPERATES ON 120 V 60 HZ A C CURRENT SEE MOTOR LABEL FOR AMPERAGE THIS UNIT MAY BE MOUNTED BEHIND ANY STATIC WALL VENT OR MODELS VX1818 OR CX2121 AUTOMATIC SHUTTERS Step 1 For new installation or installation behind existing louvers using 2 x 4 studs frame an opening at least 18 in square depending on stud spacing on center on the attic side of the gable New Construction before vent installation Mounted Frame l l Step 2 Cover the openin
2. also bear the cost of replacement of any part or component and the shipping charges incurred for the replacement and return of any part or component not covered by this warranty including parts or components damaged by customer Ventamatic Ltd reserves the right to demand and receive written evidence of the date of purchase before undertaking to perform its obligations under this warranty YOU SHOULD THEREFORE RETAIN YOUR SALES SLIP AND ATTACH IT TO YOUR WARRANTY CLAIM In order to obtain the replacement of a part or component you must select one of the following methods A Return to factory Return postage prepaid the fan or part you believe to be defective to the address below Ventamatic Ltd 100 Washington Street Mineral Wells TX 76067 Include your name amp address and a copy of your proof of purchase or installation B Return to place of purchase There is no informal dispute settling mechanism available in the event of a controversy involving this warranty Any and all implied warranties shall be limited to the duration of the express warranty set forth above In some states limitations of the duration of implied warranty do not apply Ventamatic Ltd shall not be liable for incidental or consequential damages whether direct or indirect based upon breach of warranty breach of contract negligence or tort If any suit or other action is brought against Ventamatic by customer Ventamatic and customer irrevocably waive the right to
3. g with a square piece of plywood paneling or sheetrock at least 21 in square depending on stud spacing Cut a 15 in diameter hole in the center of this panel to allow the shroud of the fan to enter the hole It is important to block off any remaining open vent area in the gable 21 inch square plywood 5 15 inch diameter circle 18 square opening A Step 3 With the nuts and bolts furnished secure the 4 mounting brackets to the shroud and then fasten the unit to the frame Mounting the long side of the L brackets with the long side to the shroud may better fit N your installation and also help reduce vibration Also the use of a sound dampening barrier such as rubber washers or foam Stripping will help reduce resonance in the walls Seal off any exhaust vent gaps fan amp around the fan in order for the fan to function at maximum efficiency secure the 4 mounting brackets TIP MUCH OF THE PREPARATION WIRING OF THERMOSTAT TESTING AND MOUNTING TO THE FRAME CAN BE DONE BEFORE FINAL INSTALLATION IN THE ATTIC FOR INSTALLATION BEHIND TRIANGULAR GABLE VENTS For installation on triangular gable vents refer to steps 1 3 on the opposite page and the following illustrations for references THERMOSTAT INSTALLATION POWER SUPPLY TO MOTOR 120 V 68 HZ WARNING Before wiring the thermostat turn the power off at the breaker to avoid electrocution Be certain to c
4. ol INSTALLATION INSTRUCTIONS FOR GABLE MOUNTED VENTILATORS Models VX2500 CX2500 VX2516 CX1600 VX2515 CX1500 Read all warnings and instructions before beginning to install this fan FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN INJURY OR EVEN DEATH Do not attempt to use this fan with any solid state speed control device Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning this unit switch power off at the service panel and lock out to prevent power from being switched on accidentally When service disconnecting means cannot be locked securely fasten a prominent warning tag to the service panel Installation work and electrical wiring must be performed by a qualified person in accordance with all applicable codes and standards including fire rated construction When cutting or drilling into a wall or ceiling do not damage electrical wiring and other hidden utilities The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacture s guideline and safety standards such as those published by the National Fire and Protection Association NFPA and the American Society for Heating Refrigeration and Air conditioning Engineers ASHRAE and the local code authorities CAUTION This unit has an unguarded propeller Do not use in
5. onfirm to all Local Electric Codes and Regulations Remove the cover from the thermostat box and use screws to attach the mounting plate to a stud When installing the thermostat box use screws to attach it to the stud to prevent damage to the control Leave the back side of the control unobstructed to allow free air circulation behind the box Wire the unit to the incoming power supply according to the diagram below The thermostat is adjustable Recommended setting is 90 110 degrees F depending on local temperatures e The fan will run as long as the attic temperature remains above the set temperature VENTAMATIC LTD LIMITED WARRANTY Ventamatic Ltd extends this warranty to the original occupying owner of the home where this product is installed that this product will be free from defects of material or workmanship for the time period listed by model number below VX2500 LIMITED LIFETIME CX2500 LIMITED LIFETIME VX2516 LIMITED 2 YEAR CX1600 LIMITED 2 YEAR VX2515 LIMITED 2 YEAR CX1500 LIMITED 2 YEAR No subsequent purchaser of this product or of the home in which the product is installed is entitled to the benefits of the warranty Ventamatic Ltd will replace the defective part or component only and return the new part to you freight prepaid Customer must bear all other expenses incurred including labor required for field repair or replacement and cost of return shipping of the defective part or component to Ventamatic Customer must
6. trial by jury Purchase and installation of this product constitutes acceptance of the terms of this warranty by customer Rev 06 12 2012 VENTAMATIC LTD